Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
RES2007-02172
PREPARED 6/27/08, 12:53:00 INSPECTION TICKET PAGE 1 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 6/27/08 ------------------------------------------------------------------------------------------------ ADDRESS 3702 DOVE HOLLOW LN SUBDIV: CONTRACTOR ED FROEHLING BUILDERS PHONE (979) 776-8266 OWNER . . PHONE PARCEL . . 230100-0102-0020 APPL NUMBER: 07-00002172 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 10/02/07 JGM BLDG, FOUNDATION -SLAB TIME: 17:00 10/02/07 AP October 2, 2007 11:46:28 AM kwolfe. Strings On Setbacks O.K. Slab Ground Installed B120 01 10/17/07 RH BLDG, FRAMING -PARTIAL TIME: 17:00 10/17/07 AP October 16, 2007 11:19:02 AM kwolfe. APA - wednesday morning B115 01 12/04/07 OC BLDG,'FRAMING TIME: 17:00 12/04/07 AP December 3, 2007 2:52:47 PM kwolfe. B130 01 12/07/07 OC BLDG, INSULATION TIME: 17:00 A 12/07/07 CA December 6, 2007 2:04:36 PM kwolfe. B130 02 12/10/07 OC BLDG, INSULATION TIME: 17:00 O 12/11/07 AP December 10, 2007 3:10:13 PM kwolfe.(� B125 01 6/24/08 BB BLDG, FINAL TIME: 17:00 "; V 6/24/08 DP June 24, 2008 10:35:08 CCOURT. Need attic insulation. Irrigation installed (�� B125 03 6/ 7/08 I BLDG, FINAL TIME: 1 :00 ® o %�O + �L June 27, 2008 12:44:46 PM acarter. B125 02 6/27/08 BB BLDG, FINAL TIME: 17:00 6/27/08 DP June 27, 2008 8:50:12 AM acarter. Still need attic insulation. -------------------------------------- COMMENTS AND NOTES-------------------------------------- 0 (6/30%2008) Amber Carter - Re: Calling for CO for 3702 Dove Hollow Ln Page 1 From: Mitchell Carson To: Amber Carter; Benjamin McCarty; Chris Haver; Gina Southerland; Joe G... Date: 6/30/2008 7:44 AM Subject: Re: Calling for CO for 3702 Dove Hollow Ln This one is ok...... Mitch >>> Amber Carter 06/27/08 8:51 AM >>> by 07-2172 Any issues? 06/24/2008 09:33 9797740565 ED FROEHLING BUILDER PAGE 02/03 e VTEXUAS SPC8 TERMITE TREATMENT DISCLOSURE DOCUMENT • 1 1 fta"-Omnex. . FROEHLING HOMES LQQTftA-tQAQ—TEQateAA 3702 DOVE HOLLOW Approxi a ego be Treated,, 2082 P�rcenta,_, aeo�xmt�cic�e(s1 to J�..�Rl�lif�JQ��ti�ta Q��:ru�a� di al XX HorizontallPerimeter Beam XX �o��#io�� 5�.,,,� �is�i�g• BRIG �[9t�gr�se: ��.�IbENC� �o�. CS��IAL2S1_T_iON [ 11 A LABEL FOR ANY OTHER PESTICIDE RECOMFNDED OR USED HAS BEEN ATTACHED AS PART OF THIS DOCUMENT. WARRANTY INFORMATION (IF ANY) INCLUDING AREA COVERED, TIME pER10D OF WARRANTY, RENEWAL OATIONSAND COST, THE OBLIGATIONS OF THE PEST CONTROL OPERATOR TO RE. TREAT FOR TERMITE, INFESTATIONS Ott REPAIR DAMAGE CAUSED BY TCRMITE INFESTATIONS WITHIN THE WARRANTY PERIOD, AND THE cONOITim THAT COULD DEVELOP AS A RESULT DF THE OWNER'S ACTION OR INACTION THAT WOULD VOID THE WARRANTY HAS ALSO BEEN ATTACHED. Charges for pre -treat, NOTES: Annual ire -newel; $30'4.18 $125.00 32129 PT 10/1/2007 Ca or TachImIn" SPCt3 j1cana9 0l 52Y79 P7 0 06/24/2008 09:33 9797740565 ED FROEHLING BUILDER PAGE 03/03 n ACE PEST CONTROL T.P.C.L. # 7120 PT PO BOX 4474 BRYAN, TX 77805 (979) 823-7777 (979) 774-4736 CERTIFICATE The following property 3702 DOVE HOLLOW built by FROEHLI NG HOMES State of Texas County of BRA rQS the city of COLLEGE STATION, Mailing Address, SAME, Zip code 77$45 was treated for subterranean termites on this day OCTOBER 01, 2007 and has met with. approval. Cost of initial treatment, $304.18, is payable upon completion of work. The treatment is guaranteed for 12 months from the date of treatment. Thereafter, this contract is subject to annual renewal (OPTIONAL) upon payment of annual inspection and renewal .fee of 1S 20 plus tax, for a period of_ _a -. years. ( see attached letter) if at any time during this contract a reinfestation of subterranean termites should occur, the above said property will be treated at no additional cost to the owner. ACE PEST CONTROL does not accept any liability for any subterranean termite damage repair. Failure to pay the annual renewal .fee within thirty days after the inspection date shall be construed as a cancellation of this contract Any alteration or addition to the foundation of the above described property without proper termite treatment by ACE PEST CONTROL Services shall nullify this contract. Licensed and regulated by Structural Pest Control Board P.Q. BOX 1927 Austin, TX 78767-1927 (512) 305-8250 0 WF0938926 / 001 City oft" C' I' ege Station PAGE 1 REQ. DATE: 07/30/07 07/30/07 13:45:48 LOCATION: 3702 DOVE HOLLOW LN LOC ID: 205454 REQUESTOR: ED FROEHLING BUILDER ORIGIN: CUSTOMER -WALK IN REQ USER: GLSOUTH AUTH USER:GLSOUTH WRK TYPE: SWR 4" WTR 3/41' ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 07/30/07 SCHED COMPLETION: 07/30/07 ******************************************************************************** JOB ORDER RESULT COMMENTS BUILD:UTG PERMIT CITY OF COLLFOC'� STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ------------------------------------------------------------------------- -- Application Number . . . . . 07-00002172 Date 7/30/07 Application pin number . . . 005404 Property Address . . . . . . 3702 DOVE HOLLOW LN Property ID: 230100-0102-0020 R #: R Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 108834 Owner Contractor ------------------------ ------------------------ ED FROEHLING BUILDERS 3887 HIGH LONESOME RD COLLEGE STATION TX 77845 (979) 776-8266 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID N/A FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1649.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC TAZ 405.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . GS Permit pin number . 516062 Permit Fee . . . . 487.00 Plan Check Fee .00 Issue Date . . . . 7/30/07 Valuation . . . . 108834 Expiration Date . . 1/26/08 Qty Unit Charge Per Extension BASE FEE 460.00 9.00 3.0000 THOU BLDG, VAL 100001-500000 27.00 ---------------------------------------------------------------------------- Special Notes and Comments -Narrow Wall Bracing Fully Sheathed with APA Dining and Garage Framing per Plans. Also to Left of Front Door are ----------------------------------------------- -- ---A-wlI-&-o----------- BUILDING DEPT REPRESENTATIVE6 APPLICANT: BUILDING PERMIT CITY OF COLLEGE -STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov Application Number . . . . . 07-00002172 Application pin number . . . 005404 Page 2 Date 7/30/07 Special Notes and Comments Interior Anchors and Bracing. ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTERS) PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE ISSUED. PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8" side & 16" front) For Openings >6 sq. ft. (12" side & 20" front) ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR ATTACHED GARAGES SHALL HAVE PENETRATIONS SEALED Assure Proper GFI Locations, Outside A/C Unit GARAGE DOOR HEADER ALL TOP PLATE AND HEADER Including One Within 25' Of PROTECTION FROM IMPACT - APPLIANCES jED IN A GARAGE----------------------------------------------1� ��---------- BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE•STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 07-00002172 Date 7/30/07 Application pin number . . . 005404 7 ----------------------------------------------------------------------- Special Notes and Comments OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED IN ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT A Minimum of No. 15 Asphalt Felt or Other Approved Water Resisitive Barrier Shall be Placed Over All Exterior Sheathing Per 2006 IRC Section R703.2 THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12' ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2006 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe to U.V. light. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE For residential applications with a glazing area that exceeds 150 of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. BUILDING DEPT REPRESENTATIVE: xl� APPLICANT: BUILDING PERMIT CITY OF COLLEGE'STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov Application Number . . . . . 07-00002172 Application pin number . . . 005404 Page 4 Date 7/30/07 Special Notes and Comments PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO GLAZING RATIO UP TO 20% A .40 OR LOWER FACTOR AND ABOVE 20% TO 30% A .35 FACTO OR LOWER SHALL BE MET. ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND CLOTHES DRYERS. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ----------------------------------- BUILDING DEPT REPRESENTATIVE: 1 APPLICANT: _ BUILDING PERMIT CITY OF COLLEGE•STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 5 Application Number . . . . . 07-00002172 Date 7/30/07 Application pin number . . . 005404 ---------------------------------------------------------------------------- Fee summary Charged ---------- Paid ---------- Credited ---------- Due ---------- ----------------- Permit Fee Total 487.00 487.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1237.00 1237.00 .00 .00 BUILDING DEPT REPREZENTATIVE: APPLICANT: - '� 1/, . - J we , 8 6 Crn 08 I;,..ot;��. S�n'rlpni APPLICATION FOR BUILDING PERMIT I101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764.3570 (979) 764.34DO FAX WWW.GSTX.GOv 1 0 �/ pArF: _ © Y � �O APPLICATION # TEMP POLE N ADDRESS/LOCATION:_. LA --A ' n0112" _ L~1 I LOT L Z SUBDIVISION 010vel CG�ss; /SEC/PH. BUSINESSIOWNER NAME: PHONE: CONTRACTORIHOMEQWNER: ��' rol?;nl, �v�IdP� Y`�. PHONE: g �`�t;' CONTACT PERSON FOR REVIEW COMMENTS: _ / _ PHONE: %96- SZG� FAX: `i7q• 056� ELECTRICIAN: HVAC: ') rvta/Cvl ✓�i EMAIL: -- PLUMBER: GOOD CENTS (Residential only): ACGE35ORY/STORAGE LOCATION ADDITION O)AOVING DEMOLITION (Asbestos Survey) NEW CONSTRUCTION' DUPLEX (Landscape Plans) REMODEURENOVATIO4N° DESCRIPTION OF WORK: PROPOSED USE: RE -ROOF SHELL ONLY SLAB ONLY SVVItAMING POOL TENT/CANOPY HOMEOWNER ASSOCIATIONiARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: _ TEXAS ACCESSIBILITY STANDARD (T/iS) PROJECT REGISTRATION# EASPRJ _ VALUATION: $ I 83G' TOTAL AREA: Z180_- HEATED AREA: I �-F irnct of bar and Materials) PUBLIC SEWER SEPTICCTREATMENT SYSTEM SEWER TAP: `' - " SIZE WATER TAP; 3/4 SIZE NUMBER OF BEDROOMS: 13 NumsER OF BATHROOMS: ILI INTERIOR WALL TYKE: EXTERIOR WALL TYPE: OTHER TAP: FOUNDATION TYPE: Sszr [� TEMP POLE ROOF TYPE: GARAGE TYPE. SINGLE DOUBLE TRIPLE ATTACHED DETACHED � CARPORT I .� SIGNATURE OF APPLICANT:���l���y/�J � `If proposed work involves new commercial construction or facade imp roveme ,renovations to an existing commercial property, building elevations are required. ♦es000e000eooeo♦ee+eo♦0000eooe®e00000eovsaeoeoeeoeseoee+ro�o♦ 0MC181 Use Only Plans Examiner Zoning Official Fire Marshall C ents: ES NO Energy Code Compliance Information or ration % Glazing of exterior walls �� •� Insulation R value of exterior walls / Insulation R value of ceiling i (fiat areas) -3 Insulation R value of ceiling 2 (vaulted areas/no attic) N1A / Glazing SHGC (Solar Teat Gain Coefficient) Glazing U-Factor R value of ductwork / AJC SEER Rating ,. Protection- Against ►Subterranean. Termites !� Chemical Termiticide Treatment (Soil Treatment) ® Chendcal Ternvticide Treatment (Field Applied Wood Treatment) Physical. Barriers -3Other R *V eriftcation of Application shall be submitted to the City of College Station Building Department prior to issuance of the Certificate of Occupancy. .0 PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# D 1 DATE: BUILDING ADDRESS: d✓� o��ow I. Foundation Requirements- Minimum City Foundation Standards NA/ A. Concrete minimum compression strength of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier Emil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior, unless over 60' long must be 30" 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated K II. Framing: Floor, Wall, Ceiling and Roof Requirements A/ A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex OK 1. One -hour rated extending to roof deck OK E. Header sizes indicated on plans N F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing 2. Moisture barrier indicated on plans 3. Exterior Wall Covering J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size, s acin , roof slope & purlin bracing if required to reduces an O. Roof covering P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations .1 PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only S. All walls within 3' of property line to have protected openings. III. Stairway Requirements OK OK A. Stairway Details OK 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8 B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements N A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening ? 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must meet IRC Chapter 10 Requirements V. Electrical Service Requirements A. Electrical plan to include: NA/ 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location I PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX VI. Plumbing Requirements A. Pressure reducing valve required when water pressure exceeds 80 psi NA/PM B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units) T B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) Vill. Energy Requirements N A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 NA/ Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements N Maximum drive width for residence is 25' combined for circular and 12' minimum for single Minimum 20 feet from driveway to side(intersecting) street property line sight triangle Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 N Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 NMOIJ Does not block any water course or divert any flow VOK Elevation certificate needed "APPROVED PLANS PER IRC SECTION R106.3.1." 4,0t �__ PLANS EXAMINER 7-z1�--0'7 DATE DOVE CROSSING SUBDIVISION V uG— io Lo Lo LOT 3 SCALE: 1" = 20' —5� ELECTRIC BOX 1' It,, ---FROM CORNER 3702 DOVE HOLLOW LANE �✓ N I I V REScheck Compliance Certificate 2000 IECC RES check Software Version 3.5 Release lb Data filename: C:\Program Files\Check\REScheck\3702DH 40.5 GILES TITLE: 3702 DOVE HOLLOW LANE CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 07/ 10/07 DATE OF PLANS: 6/29/07 PROJECT INFORMATION: 40.5 GILES LOT 2 BLOCK 2 DOVE CROSSING PHASE 1 C COMPANY INFORMATION: ED FROEHLING BUILDER, INC. COMPLIANCE: Passes Maximum UA = 421 Your Home UA = 320 24.0% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.36 Ceiling 1: Flat Ceiling or Scissor Truss Wall 1: Wood Frame, 16" o.c. Window 1: Metal Frame:Double Pane with Low-E SHGC: 0.40 Bldg. faces 45 deg. from North; Comp. orient.: Front Projection factor: 0.29 Door 1: Solid Wall 2: Wood Frame, 16" o.c. Window 2: Metal Frame:Double Pane with Low-E SHGC: 0.40 Bldg. faces 45 deg. from North; Comp. orient.: Left Side Projection factor: 0.33 Wall 3: Wood Frame, 16" o.c. Window 3: Metal Frame:Double Pane with Low-E SHGC: 0.40 Bldg. faces 45 deg. from North; Comp. orient.: Back Permit Number Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA 1649 30.0 0.0 58 324 13.0 0.0 19 51 0.640 33 38 0.400 15 454 13.0 0.0 35 31 0.640 20 324 13.0 0.0 17 114 0.640 73 Projection factor: 0.29 Wall 4: Wood Frame, 16" o.c. 454 13.0 0.0 35 Window 4: Metal Frame:Double Pane with Low-E 8 0.640 5 SHGC: 0.40 Bldg. faces 45 deg. from North; Comp. orient.: Right Side Projection factor: 0.33 Door 2: Glass 18 0.580 10 SHGC: 0.78 Bldg. faces 45 deg. from North; Comp. orient.: Right Side Projection factor: 0.25 Air Conditioner 1: Electric Central Air, 13 SEER COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in REScheckVersion 3.5 Release lb (formerly MECchec� and to comply with the mandatory requirements listed in the RES checkInspection Checklist. Builder/Designer Date �