WF0949179 / 001 City of College Station
PAGE 1
REQ. DATE: 08/09/07 08/09/07 10:49:01
LOCATION: 2801 HORSEBACK DR LOC ID: 208698
REQUESTOR: CHRISTOPHER MICHAEL HOMES ORIGIN: CUSTOMER -WALK IN
REQ USER: ACARTER AUTH USER:ACARTER WRK TYPE:
WTR 3/4" SWR 4"
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 08/09/07 SCHED COMPLETION: 08/09/07
********************************************************************************
JOB ORDER RESULT COMMENTS
Amber Carter - Re: Calling for CO for 2801 Horseback Dr Page 1
From: Terry Boriskie
To: Amber Carter; Benjamin McCarty; Chris Haver; ...
Date: 11/14/2007 12:20 pm
Subject: Re: Calling for CO for 2801 Horseback Dr
Notified George Lopez at 324-3916
Terry Boriskie
City of College Station
Residential Plans Examiner
979-764-3744
>>> Mitchell Carson 11/14/2007 12:13 pm >>>
The sewer clean out box is broke. Needs to be replaced.
Mitch
>>> Amber Carter 11/13/07 12:24 PM >>>
by 07-2104
Any issues?
PREPARED 11/13/07, 12:04:18 INSPECTION TICKET PACE 8
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 11/13/07
------------------------------------------------------------------------------------------------
ADDRESS . : 2801 HORSEBACK DR SUBDIV: HORSE HAVEN PH 3
CONTRACTOR CHRISTOPHER MICHAEL HOMES PHONE (313) 775-9070
OWNER . . PHONE
PARCEL . . 336300-0304-0030
APPL NUMBER: 07-00002104 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 8/02/07 DS BLDG, FOUNDATION -SLAB TIME: 17:00
8/02/07 AP August 1, 2007 2:16:32 PM acarter.
EARLY MORNING PLEASE
B115 01 8/28/07 DS BLDG, FRAMING TIME: 17:00
9/04/07 DP August 28, 2007 12:40:58 PM kwolfe.
09/04/2007 04:38 PM DS PDA
nailing pattern not to apa specs tape tyvek fireblock
fir down around laundry room fire block by front door
B115 02 9/06/07 RH BLDG, FRAMING TIME: 17:00
9/06/07 DP September 6, 2007 10:35:53 AM kwolfe.
09/06/2007 04:55 PM RH PDA
Did not correct APA nailing pattern. Need to complete
fireblocking for fur down in utility room.
B115 03 9/07/07 DS BLDG, FRAMING TIME: 17:00
9/07/07 AE September 7, 2007 10:39:44 AM acarter.
09/07/2007 03:40 PM DS PDA
FYI window right side of backdoor needs to be tempered by
by final
meet frammer on previous notes
B130 01 9/11/07 JGM BLDG, INSULATION TIME: 17:00
9/11/07 AP September 11, 2007 10:24:38 AM acarter.
B125 01 11/13/07 IX,, BLDG, FINAL TIME: 17:00
(5_ November 13, 2007 10:01:08 AM acarter.
Still need tempered glass. If this is only issue, okay for,, -
__temp CO, pet Terry'.- -
-------------------------------------- COMMENTS AND NOTES--------------�-------------------
je(cy
1
g
Date: 11 /13/2007
Inspection Comments for Finals
Permit Year: 7 Permit Number: 2104
Address: 2801 HORSEBACK DR
Type
Inspection Type Code
Description
status
Inspection Result Comments
B115
BLDG, FRAMING
IC
09/04/2007 04:38 PM DS PDA
B115
BLDG, FRAMING
IC
nailing pattern not to apa specs tape tyvek fireblock
B115
BLDG, FRAMING
IC
fir down around laundry room fire block by front door
B115
BLDG, FRAMING
IC
09/06/2007 04:55 PM RH PDA
B115
BLDG, FRAMING
IC
Did not correct APA nailing pattern. Need to complete
B115
BLDG, FRAMING
IC
fireblocking for fur down in utility room.
B115
BLDG, FRAMING
IC
09/07/2007 03:40 PM DS PDA
B115
BLDG, FRAMING
IC
FYI window right side of backdoor needs to be tempered
B115
BLDG, FRAMING
IC
by final
B115
BLDG, FRAMING
IC
meet frammer on previous notes
E110
ELEC, ROUGH IN
IC
September 4, 2007 4:43:19 PM kwolfe.
E110
ELEC, ROUGH IN
IC
bond pancake boxes; unbundle homeruns at panel
E110
ELEC, ROUGH IN
IC
09/06/2007 10:06 AM DS PDA
E110
ELEC, ROUGH IN
IC
still needs stringers in dinning room,livingroom and front
E110
ELEC, ROUGH IN
IC
bedroom
E150
ELEC, FINAL
IC
11/09/2007 11:24 AM JGM PDA
E150
ELEC, FINAL
IC
back porch ceiling fans miswired, ceiling fan in master
E150
ELEC, FINAL
IC
bath does not have proper clearance over tub, need bulbs
E150
ELEC, FINAL
IC
in master closet, light on front porch ceiling fan not
E150
ELEC, FINAL
IC
working
Page 1
NOV-14-2007 12:47 From:A-1 TERMITES
To:7643496
Pa9e:112
FAX COVED
SHEET
A-, 1 Termites
979-589-1203 OFc 979-589-3655 Fax
P.O. Box 5481, Bryan, TX 77805
14 November 2007
Rusiness Name: City of College Station
Attention: Amber Sent From: Russell & Katie Breland
Fax Number: 979-764-3496 Faxed From- 979-589-3655
The information contained in this fax is wnfidmtial and privileged. It is intended Ibr the. cxchisive. use by the individual or entity to
which it is addressed and any copying, distribution, disclosure, or taking of any action because of this information is strictly
prohibited. If you mzi.vr fhis fax in error please contacl us inunediately by telephonic to turan a for the return of this dnk:urnent,
[ ] Urgent [ ] Reply ASAP [ ] Please Conirnent DQ PIcasc review [) For your infortnal-ion
Total Pages Sent including Cover:
Message/Comments:
Amber,
If you need anything else please call me.
Thanks,
Katie Breland
A- 1 Termites
2
if you did not receive: the eaitirt: fax listed above or receive it in error please call our office at 979-589-1203,
-1 ermi es
P.O. Box 5481, Bryan, TX 77805-5481
979-589-1203 oft 979-589-3655 Fax
Certificate of Completion
This certificate verifies the completion of the
preconstruction Bora Care Wood Treatment for
subterranean termites for the property listed below.
Christopher Micheal Homes
2-8oi Horseback Drive
College Station, TX77845
This property is guaranteed against subterranean termite
infestation from 14 Sept 2007 tbru 14 Sept 20.09.
R w,vkPiLL C . r �iLa.n-cL
RuSSELL C. BRELAND, CA
z
0
c
N
N
0
m
N
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE S'4'iN, TX 77840
PHONE: (979)764-3570 .FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Application Number . . . . . 07-00002104 Date 7/23/07
Application pin number . . . 506200
Property Address . . . . . . 2801 HORSEBACK DR
Property ID: 336300-0304-0030
R #•
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . HORSE HAVEN PH 3
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 115000
Owner
Contractor
------------------------
------------------------
CHRISTOPHER MICHAEL HOMES
1610 LUZA ST
BRYAN
TX 77802
(313) 775-9070
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
N/A
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
1486.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
2.00
NUMBER OF BEDROOMS
3.00
SEWER TYPE
PUBLIC
TAZ
285.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING
PERMIT
Additional desc . . AC
Permit pin number 514802
Permit Fee
505.00 Plan Check Fee
.00
Issue Date . . . .
7/23/07 Valuation . .
. . 115000
Expiration Date . .
1/19/08
Qty Unit Charge
Per
Extension
BASE FEE
460.00
15.00 3.0000
THOU BLDG, VAL 100001-500000
45.00
----------------------------------------------------------------------------
Special Notes and Comments
-Make Sure Foundation
Beams at Rear Porch area Continues
throughout continuous
and meet Minimum C ty Stan ards.
------------------------------------------
BUILDING DEPT RePR.ESENTATIVE:
APPLICANT:
57.02'
I
I
I
REAR
�
SETBAC14i
I
1
I
i
Lo
I
1
1 i
I I
Y I
U I
I
I
I Y
I U
1
I
o m I
I m
ao I N I
I
1.
'-I
NI
UJ
N
I
40'— 1
2"
I ca
I
I �
I
W-2 1 I"
j
8 8 3/1 "
I
16' WIDE
°
`CONC
HORSE HAVEN
DRIVE
PH-3
BLK-4
LOT-3
I
57.00'
Z%V j HORSEBACK DR.
SITE PLAN
SCALE: 1 "=20'-0"
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 07-00002104
Application pin number . . . 506200
Page 2
Date 7/23/07
Special Notes and Comments
-Narrow Wall Bracing Fully Sheathed with Simpson Panel at
Back Porch Area per Plans and APA Garage Framing.
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED
IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE
ISSUED.
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
PLATFORM FOR MECHANICAL EQUIPMENT AND/O ACCESS MAY HAVE TO
----------------------------------------- -- ---- -------------
BUILDING DE��PRESENTATIVE: �.
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 07-00002104
Application pin number . . . 506200
Page 3
Date 7/23/07
Special Notes and Comments
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
A Minimum of No. 15 Asphalt Felt or Other Approved Water
Resisitive Barrier Shall be Placed Over All Exterior
Sheathing Per 2006 IRC Section R703.2
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2006 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 150 of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY M
BUILDING DE
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 07-00002104
Application pin number . . . 506200
Page 4
Date 7/23/07
Special Notes and Comments
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO
GLAZING RATIO UP TO 20o A .40 OR LOWER FACTOR AND ABOVE 200
TO 30o A .35 FACTO OR LOWER SHALL BE MET.
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND
CLOTHES DRYERS.
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary
Charged
----------
Paid
----------
Credited
----------
----------
Due
-----------------
Permit Fee Total
505.00
505.00
.00
.00
Plan Check Total
.00
.00
.00
.00
Other Fee Total
750.00
750.00
.00
.00
Grand Total
1255.00
1255. 0
.00
.00
--------------------------------------------
-----Akao
-----------BUILDING
DEPT—AEPRESENTATIVE:
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE.
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
07-00002103 Date 7/23/07
Application pin number . . .
250838
Property Address . . . . . .
2801 HORSEBACK DR
Property ID:
336300-0304-0030
Application type description
TEMP POLE
Subdivision Name . . . . . .
HORSE HAVEN PH 3
Property Use . . . . . . . .
RESIDENTIAL
Property Zoning . . . . . . .
SINGLE FAMILY RESIDENTIAL
Application valuation . . . .
0
Owner
Contractor
------------------------
------------------------
CHRISTOPHER MICHAEL
HOMES
1610 LUZA ST
BRYAN
TX 77802
(313) 775-9070
----------------------------------------------------------------------------
Permit . . . . . . TEMP POLE
PERMIT
Additional desc . . AC
Permit pin number . 514810
Permit Fee . . . . 20.00
Issue Date . . . . 7/23/07
Valuation . . .
. 0
----------------------------------------------------------------------------
Other Fees . . . . . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary Charged
----------
Paid Credited
------------------------------
Due
-----------------
Permit Fee Total 20.00
20.00 .00
.00
Other Fee Total 45.00
45.00 .00
.00
Grand Total 65.00
65.00 .00
.00
-------------------------------------------✓ ------ - -----------
BUILDING DEPT REMESENTATIVE:
APPLICANT:
APPLICATION FOR BUILDING PERMIT
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
Crry op COLLEGE. $TAT.IoN. (979) 764-3570 (979) 764-3496 FAX
Pla„niiig:i .:,Pow oA rieili'Se Yids+.
WWW.CSTX.GOV
6i f -F i EV /
DATE: TRCQ REG /
APPLICATION # 047210
TEMP POLE # �O
ADDRESS/LOCATION: C3, $ O ! +V
LOT —3_yLBLOCK SUBDIVISION qvcs���� _gja=41'
BUSINESS/OWNER NAME_ l-_1n i I S�00
CONTRACTOR/HOMEOWNER: 10,RA0r4- e up Qty PHONE
CONTACT PERSON FOR REVIEW COMMENTS: �,•r _L7
FAX:
ELECTRICIAN: G � Q E f C_,6-C
HVAC: O_1) maAc- VV A-S 6
PHONE: 3Z4- 2 [ 14,
EMAIL: !�LOflez r,
PLUMBER:
GOOD CENTS (Residential only):
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTIONSLAB ONLY
DUPLEX (Landscape Plans) REMODEURENOVATION' SWIMMING POOL
TENT/CANOPY
DESCRIPTION OF WORK:
PROPOSED USE:
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TA ) PROJECT REGISTRATION# EABPRJ
VALUATION: $ 1S TOTAL AREAQr-O5_ HEATED AREA:
(Cost of L bor and Materials)
[?]/PUBLIC SEWER NUMBER OF BEDROOMS: 3
SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS:
SEWER TAP:
SIZE
WATER TAP: 3
SIZE
1-1 OTHER TAP:
�EMP POLE
GARAGE TYPE:
SIZE
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
SINGLE DOUBLE Eg---' TRIPLE
ATTACHED U.,�DETACHED [::] CARPOR
SIGNATURE OF APPLICANT: _ (
`If proposed work involves new commerc
commercial property, building elevations
�2,o T
�(q Plans Examiner
facade
Ofclal Use Only
Zoning Official
CES eN0
.5vve e t V-6 C,
7
to an existing
/ Fire arsh '"'
-' Wake oi4v =�
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1, (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic) R 1 C(
Glazing SHGC Solar Heat Gain Coefficient
( )
Glazing U-Factor �e
R value of ductwork (�
A/C SEER Rating 1-3
/
Protection Against Subterranean Termites
ri
❑ Chemical Termiticide Treatment (Soil Treatment)
D- Chemical Termiticide Treatment (Field Applied Wood Treatment)
❑ Physical Barriers
❑ Other
*Verification of Application shall be submitted to the City of College Station
Building Department prior to issuance of the Certificate of Occupancy.
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# Q _ a D
DATE: '7 ao-o"7
'
BUILDING ADDRESS:
1;).1 B o& se Lae- IL
I. Foundation Requirements- Minimum City Foundation Standards
NA/ K
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F.
Wood foundation details indicated
OK
II. Framing: Floor, Wall, Ceiling and Roof Requirements
N
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
N K
1. One -hour rated extending to roof deck
E.
Header sizes indicated on plans
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
.,
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
III. Stairway Requirements
a Ar..
AJb M(
&&90 K
A. Stairway Details
OK
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
NA/
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
N
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
,p
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
N K
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
N
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
WOW
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
N K
Does not block any water course or divert any flow
Elevation certificate needed
"AlK
"APPROVED PLANS PER IRC SECTION R106.3.1."
PLANS EXAMINER DATE