HomeMy WebLinkAboutRES2007-02099PREPARED 7/02/08, 8:06:00 INSPECTION TICKET PAGE 2 City of College Station INSPECTOR: BUILDING.INSPECTOR DATE 7/01/08 ------------------------------------------------------------------------------------------------ ADDRESS . : 3714 DOVE HOLLOW LN SUBDIV: CONTRACTOR ED FROEHLING BUILDERS PHONE (979) 776-8266 OWNER . . PHONE PARCEL . . 230100-0102-0080 APPL NUMBER: 07-00002099 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 8/27/07 OC BLDG, FOUNDATION -SLAB TIME: 17:00 8/27/07 AP August 24, 2007 4:45:59 PM kwolfe. Strings On Setbacks O.K. Slab Ground Installed B120 01 10/09/07 OC BLDG, FRAMING -PARTIAL TIME: 17:00 10/09/07 AP October 8, 2007 3:26:28 PM kwolfe. APA framing B115 01 11/06/07 RH BLDG, FRAMING TIME: 17:00 11/06/07 DP November 6, 2007 10:15:45 AM kwolfe. 11/06/2007 03:34 PM RH PDA Anchors at backdoor. Joist hangers at hallway, master and garage. Loose studs at utility. Repair loose Tyvek and tape seams and holes through Tyvek. Hvac did not make repairs to ducts as noted on rough -in. Need to connect gas at fireplace. B115 0,2 11/09/07 RH BLDG, FRAMING TIME: 17:00 11/09/07 DA November 8, 2007 3:56:15 PM acarter. FRIDAY AFTERNOON PLEASE 11/09/2007 02:45 PM RH PDA Tape seal all holes through Tyvek as per manufacture requirements, as noted previously. B115 03 11/15/07 RH BLDG, FRAMING TIME: 17:00 11/15/07 AP November 14, 2007 3:21:31 PM acarter. B130 01 11/21/07 RH BLDG, INSULATION TIME: 17:00 11/21/07 AP: November 21, 2007 9:30:18 AM acarter. B125 02 7/01/08 BI BLDG, FINAL TIME: 17:00 —7,a' 0$ July 1, 2008 2:08:53 PM acarter. B125 01 7/01/08 BLDG, FINAL TIME: 17:00 7/01/08 DA June 30, 2008 3:12:57 PM glsouth. �Need to post energy requirements in_electrical panel.;( ,Connect electrical to a/c=condensor and secure COMMENTS AND NOTES -------------------------------------- I TERMITE TREATMENT DISCLOSURE DOCUMENT FROEHLING HOMES 3714 DOVE HOLLOW 2427 Percentaue-offertnticide(a) tQ be anpli-ed at this location., Horizontal/Perimeter Beam—XX— ..x..l.l: SLAB Sidin.BRICK • u..l► REJI12ENCE RoQfv COMPQSITlf2N A LABEL FOR ANY OTHER PESTICIDE RECOMENDED OR USED HAS BEEN ATTACHED AS PART OF THIS DOCUMENT. WARRANTY INFORMATION (IF ANY) INCLUDING AREA COVERED, TIME PERIOD OF WARRANTY, RENEWAL OPTIONSAND COST, THE OBLIGATIONS OF THE PEST CONTROL OPERATOR TO RC• TREAT FOR TERMITE INFESTATIONS OR REPAIR DAMAGE CAUSED BY TERMITE INFESTATIONS WITHIN THE WARRANTY PERIOD, AND THE CONDITIONS THAT COULD DEVELOP AS A RESULT OF THE OWNERS ACTION OR INACTION THAT WOULD VOID THE WARRANTY HAS ALSO BEEN ATTACHED, Charges for pre -treat: NOTES: Annual re-newal: $354.58 $125.00 32129 PT 8123/2007 CA or Tochlncian SPCS Ilconao Y 32129 PT i1� Z0/Z0 39VJ N3G-Iina JNI-lH309J Q3 9990VLL6L6 L£:bZ 800Z/0£/90 I 0 r w,. SUBTERRANEAN TERMITE PIRECONSTRUCTION �.�' >•> ' DISCLOSURE FOR EACH ESTIMATE 4"";. For all treatments there will be a diagram showing exactly.what will be treated prior to the beginning of treatment. Review the pesticide label provided to you at this time for minimum treatment standards. Remember that your architects or design engineers specifications must also be followed, unless they are in violation of the law, Review the consumer information sheet for further information. If you have any questions,.contact the pest control company or the Texas Structural Pest Control Board, PO Box 1927, Austin, Texas 78767-1927. Telephone number (512) 305-8250. Name of Customer Address City f State 1 dip Location to be Treated DoveI tr) w Lt,ctiQ,. Type of Treatment: [ ] Full [ artial A label of�termiticide(s) is enclosed. The percentage of the termiticide(s) to be applied at this location is Q(p 70 Warranty Information provided must include the Complete Details of any Warranty provided and the following. Timp Period of Warranty; Renewal Options and Cost; and Obligations of the Contracting Parties. If the warranty does not include the entire structure treated, the areas included in the warranty are: (specify) Total Square Feat to.be Treated: O` �� Total Linear Feet to be Treated: Approximate Measurements of the Structure(s) to be Treated: VeA-+t'(.,L. Z�o tom. (;� I 1 le/ature of Certified Applicator or Printed Name Date chn.ician Completing Estimate &:E- &-4 --� I -0-'� 0 Name of Pest Control Company TPCL. No. Licensed and regulated under the Texas Structural Pest Control Act Texas Structural Pest Control Board, PO Box 1927, Austin, Texas 78767-1927, Telephone number (512) 30$-8250. Sample Form — April 4, 2005 Page 1 of 2 Z0/i0 39dd Z13G-lina JNI-1H30dJ Q3 9990bLLGL6 LE:t T 800Z/06/90 WF0933191 / 001 City of College Station PAGE 1 REQ. DATE: 07/23/07 07/23/07 17:31:11 LOCATION: 3714 DOVE HOLLOW LN LOC ID: 205466 REQUESTOR: ED FROEHLING ORIGIN: CUSTOMER -WALK IN REQ USER: ACARTER AUTH USER:ACARTER WRK TYPE: WTR 3/4" SWR 4" ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 07/23/07 SCHED COMPLETION: 07/23/07 ******************************************************************************** JOB ORDER RESULT COMMENTS BUILDING PERMIT= CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE _STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Application Number 07-00002099 Date 7/23/07 Application pin number •007646 Property Address . . . . . . ..3714 DOVE HOLLOW LN Property ID: 230100-0102-0080 R #: R Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 126984 Owner Contractor ------------------------ ------------------------ ED FROEHLING BUILDERS 3887 HIGH LONESOME RD COLLEGE STATION TX 77845 (979) 776-8266 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1924.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC TAZ 405.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . AC Permit pin number . 514877 Permit Fee . . . . 541.00 Plan Check Fee .00 Issue Date . . . . 7/23/07 Valuation . . . . 126984 Expiration Date . . 1/19/08 Qty Unit Charge Per Extension BASE FEE 460.00 27.00 3.0000 THOU BLDG, VAL 100001-500000 81.00 ---------------------------------------------------------------------------- Special Notes and Comments -Narrow Wall Bracing Fully Sheathed with APA Garage and Dining Room Area Framing _ ---------------------------------------- -�- ---------------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979) 764*-3570 FAX: (979) 764-3496 http://bpinspect.cstx.gov Application Number . . . . . 07-00002099 Application pin number . . . 007646 Page 2 Date 7/23/07 Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTERS) PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 30") WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE ISSUED. PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8" side & 16" front) For Openings >6 sq. ft. (12" side & 20" front) ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR ATTACHED GARAGES SHALL HAVE PENETRATIONS SEALED Assure Proper GFI Locations, Outside A/C Unit GARAGE DOOR HEADER ALL TOP PLATE AND HEADER Including One Within 25' Of PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES --------------------------------------------- ------.a/ -- _,e_ - - . -<' ---------- BUILDING DEPT REPRESENTAT APPLICANT: J BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 ' FAX: (979)764-3496 http://bpinspect.cstx.gov Application Number . . . . . 07-00002099 Application pin number . . . 007646 Page 3 Date 7/23/07 Special Notes and Comments PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED IN ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT A Minimum of No. 15 Asphalt Felt or Other Approved Water Resisitive Barrier Shall be Placed Over All Exterior Sheathing Per 2006 IRC Section R703.2 THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12' ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R6'02.10 IN 2006 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe to U.V. light. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE SANITARY FACILITIES FOR BUILDING DEPT REPRESENTATIVE: APPLICANT: WORK ON S E L ATLD ZF BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 ' FAX: (979)764-3496 http://bpinspect.cstx.gov Application Number . . . . . 07-00002099 Application pin number . . . 007646 Special Notes and Comments Page 4 Date 7/23/07 THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO GLAZING RATIO UP TO 20o A .40 OR LOWER FACTOR AND ABOVE 200 TO 30o A .35 FACTO OR LOWER SHALL BE MET. ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND CLOTHES DRYERS. Other Fees SEWER TAP 4" WATER TAP 3/4" 350.00 400.00 ---------------------------------------------------------------------------- Fee summary ------- Charged --------Paid--- Cred' ed Due ----------------- ------------�-'--------- BUILDING DEPT REPRESENTA APPLICANT:��� `C BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570' FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Application Number .. . . . . Application pin number . . . Permit Fee Total 541.00 Plan Check Total .00 Other Fee Total 750.00 Grand Total 1291.00 07-00002099 007646 541.00 .00 750.00 1291.00 --------------------------------------------- BUILDING DEPT REPRESENTATIVL: APPLICANT: Page 5 Date 7/23/07 ---- - - - - ------------ .00 .00 .00 .00 .00 .00 .00 .00 ----- �--'d--=--'r-_--------- CM aN COLLEa.S:TAT1ot csavaa' APPLICATION FOR BUILDING PERMIT 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979)764a3570 (979) 764.306 FAX wwVV.GSTX.GOV ZFt "�Ue10+�'YpATE:��`A APPLICATION TEMP POLE 0 _ a ADDRESS/LOCATION:-. I'_ U'_'%.LL«^---' I--^'�� LOT S V 13=K SUBDIVISION __DQ\&"" 6<Sina BUSINESS/OWNER NAME: CONTRACTOR/HOMEUWNER: �_i'l�/In- �► � --gr14L. CONTACT PERSON FOR REVIEW COMMENTS: _ n4 /M PHONE: A PHONE: _`I 16 • 8 _ PHONS: 9�. o/- ZGd FAX: 4••OSGS EMAIL: ELECTRICIAN: _ -i� {� ,nL PLUMBER: HVAC: R, J GZ 1run �,�i GOOD CENTS (Residential only): ACCE ,SORY/STORAGE.. LOCATION RE -ROOF ADDITION OVINC, SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION ' SLAB ONLY DUPLEX (Landscape Plans) REMODEI.IRENOVATI, SWIPAMING POOL TENT/CANOPY DESCRIPTION OF WORK: PROPOSED USE: HOMEOWNER ASSOCIA'TIONiARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: _ TEXAS ACCESSIBILITY STANDARD (TAS) P OJECT REGISTRATION# EASPRJ VALUATION: $ 1 � - TOTAL AREA: ZCLZ „ HEATED AREA: I IZA (Cost of Lab r and Materials) 171/p,U61-I0 SEWER SEPTICITREATMENT SYSTEM SEWER TAP: 4-P SwF WATER TAP: 3 T�r SIZE [] OTHER TAP [] TEMP POLE GARA(3E TYPE: NUrnBER OF BEDROOMS: NUMBER OF BATHROOMS: INTERIOR WALL TYIyE: EXTERIOR WALL TYPE: FOUNDATION TYPE: Ssz� ROOF TYPE: SINGLE DOUBLE TRIPLE ATTACHED DETACHED L� CARPORT SIGNATURE OF APPLICANT: - `'If proposed work involves new commercial construction or facade imps is/renovations to an existing commercial property, building elevations are required. see�o49i®?�o�40♦eeee4�o40seieae00o400eeeebeeeeeeeeo9eeeoo�O♦ Offlclal Use Only 6 A-r4� WI I -I Plans Examiner T PP �c u2gs nota0 .f+tw Aeot ege, �_o LL Zoning Official _ � �ly S�Q�M>✓ Marshall 6 m ents: • / �`" r Y or NO Energy Code Compliance InfOPM460n, Glazing of exterior walls i2• Insulation R value of exterior malls Insulation R valtie of ceiling I (flai areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC (Solar Heat Gain Coefficient) Glazing U-Factor R value of ductwork AJC SEER Rating 13 Protection Against ,Subterranean Termites Chemical Termiticide Treatment (Soil Treatment) (.� Cheini.cal. Teirniticide Treatment ()Field Applied Wood Treatment) 0 "'Physical Barriers Other *V'erifcation of Application shall be submitted to the City of College Station Building Department prior to issuance of the Certificate of Occupancy, PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# DATE: BUILDING ADDRESS: 1Do e o w Lam✓ I. Foundation Requirements- Minimum City Foundation Standards N K A. Concrete minimum compression strength of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier Emil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior, unless over 60' long must be 30" 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated OK Il. Framing: Floor, Wall, Ceiling and Roof Requirements A/ A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex OK 1. One -hour rated extending to roof deck OK E. Header sizes indicated on plans A/ F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing 2. Moisture barrier indicated on plans 3. Exterior Wall Covering J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size, spacing, roof slope & purlin bracing if required to reduces an O. Roof covering P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations .1 PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only S. All walls within 3' of property line to have protected openings. III. Stairway Requirements WOK "OK A. Stairway Details OK 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8 B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must meet IRC Chapter 10 Requirements V. Electrical Service Requirements A. Electrical plan to include: IIATV 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX VI. Plumbing Re uirements A. Pressure reducing valve required when water pressure exceeds 80 psi N B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements NAW A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units �T B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) VIII. Energy Requirements NPM A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 N Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements NMOK Maximum drive width for residence is 25' combined for circular and 12' minimum for single Minimum 20 feet from driveway to side(intersecting) street property line sight triangle Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 N Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 NA/ Does not block any water course or divert any flow Elevation certificate needed OK "APPROVED PLANS PER IRC SECTION R106.3.1." INER %-- (9 ­0 ? DATE REScheck Compliance Certificate 2000 IECC REScheckSoftware Version 3.5 Release I Data filename: C:\Program Files\Check\REScheck\3714DH 41.5 palasota.rck TITLE: 3714 Dove Hollow CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 07/12/07 DATE OF PLANS: 6/5/07 PROJECT INFORMATION: Lot 8 Block 2 Dove Crossing COMPANY INFORMATION: Ed Froehling Builder, Inc NOTES: 40.75 Palasota COMPLIANCE: Passes Maximum UA = 702 Your Home UA = 602 14.2% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.38 Ceiling 1: Flat Ceiling or Scissor Truss Wall 1: Wood Frame, 16" o.c. Window 1: Metal Frame:Double Pane with Low-E SHGC: 0.40 Bldg. faces 180 deg. from North; Comp. orient.: Front Projection factor: 0.23 Door 1: Solid Wall 2: Wood Frame, 16" o.c. Window 2: Metal Frame:Double Pane with Low-E SHGC: 0.40 Bldg. faces 180 deg. from North; Comp. orient.: Left Side Projection factor: 0.23 Wall 3: Wood Frame, 16" o.c. Window 3: Metal Frame:Double Pane with Low-E Permit Number Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA 1924 30.0 0.0 67 326 13.0 0.0 19 59 0.640 38 38 0.400 15 510 13.0 0.0 39 40 0.640 26 326 13.0 0.0 17 98 0.640 63 •4 ` .;k SHGC: 0.40 Bldg. faces 180 deg. from North; Comp. orient.: Back Projection factor: 0.23 Door 2: Glass 18 0.580 10 SHGC: 0.78 Bldg. faces 180 deg. from North; Comp. orient.: Back Projection factor: 0.23 Wall 4: Wood Frame, 16" o.c. 510 13.0 0.0 35 Window 4: Metal Frame:Double Pane with Low-E 83 0.640 53 SHGC: 0.40 Bldg. faces 180 deg. from North; Comp. orient.: Right Side Projection factor: 0.23 Floor 1: Slab -On -Grade: Unheated 211 0.0 220 Insulation depth: 0.0' Air Conditioner 1: Electric Central Air, 13 SEER COMPLIANCE STATEMENT: The proposed building design described here is cot and other calculations submitted with the permit application. The proposed building requirements in REScheckVersion 3.5 Release lb (formerly MECchec� and to corn the REScheckInspection Checklist. Date Builder/Designe r Dove Crossing Subdivision Scale: 1" = 20' N 48 04' 39" W - 56.25' 10' P.U.E.- < I - Lot 9 Block 2 9 - 56'-3" - 4=9, -6' 3714 DOVE B. HOLLOW LANE Proposed Residence Phase IC Lot 8 Block 2 - J .Concrete I Driveway I N 48 04' 39" W - 56.25' Dove Hollow Lane 50' R.O.W. - 27' Pavement ELEC BOX V FROM CORNER N h N IN zn Lot 7 Block 2 h