Date: 12/3/2007
Inspection Comments for Finals
Permit Year: 7 Permit Number: 2096
Address: 2402 STONE CASTLE CIR
Type
Inspection Type Code
Description
si ins
Inspection Result Comments
B100
BLDG, FOUNDATION -SLAB
IC
08/03/2007 04:36 PM RH PDA
B100
BLDG, FOUNDATION -SLAB
IC
Strings up, slab ground installed.
B115
BLDG, FRAMING
IC
09/11/2007 12:48 PM JGM PDA
B115
BLDG, FRAMING
IC
need interior anchors and bracing behind fireplace
B130
BLDG, INSULATION
IC
09/13/2007 11:42 AM RH PDA
B130
BLDG, INSULATION
IC
Before brick repair TYVEK. Tape seal around doors,
B130
BLDG, INSULATION
IC
penetrations and seams. Foam sealant doesn't pass as a
B130
BLDG, INSULATION
IC
moisture barrier as per Tyvek. Also, in the future TYVEK
B130
BLDG, INSULATION
IC
must cover entire wall before soffits are installed.
E150
ELEC, FINAL
IC
11/30/2007 03:23 PM RH PDA
E150
ELEC, FINAL
IC
Need plug to right of stove top and install gromet on
E150
ELEC, FINAL
IC
romex in w/h cabinet.
M110
MECH, FINAL
IC
September 11, 2007 8:00:33 AM acarter.
M110
MECH, FINAL
IC
Entered Wrong Inspection
Page 1
Date: 12/5/2007
Inspection Comments for Finals
Permit Year: 7 Permit Number: 2096
Address: 2402 STONE CASTLE CIR
Type
Inspection Type Code
Description
Status
Inspection Result Comments
B100
BLDG, FOUNDATION -SLAB
IC
08/03/2007 04:36 PM RH PDA
B100
BLDG, FOUNDATION -SLAB
IC
Strings up, slab ground installed.
B115
BLDG, FRAMING
IC
09/11/2007 12:48 PM JGM PDA
B115
BLDG, FRAMING
IC
need interior anchors and bracing behind fireplace
B125
BLDG, FINAL
IC
12/03/2007 03:07 PM RH PDA
B125
BLDG, FINAL
IC
Need to finish installing electrical plug to right of
B125
BLDG, FINAL
IC
stove top. Need to install address, handrails and post
B125
BLDG, FINAL
IC
energy requirements in electrical panel door.
B130
BLDG, INSULATION
IC
09/13/2007 11:42 AM RH PDA
B130
BLDG, INSULATION
IC
Before brick repair TYVEK. Tape seal around doors,
B130
BLDG, INSULATION
IC
penetrations and seams. Foam sealant doesn't pass as a
B130
BLDG, INSULATION
IC
moisture barrier as per Tyvek. Also, in the future TYVEK
B130
BLDG, INSULATION
IC
must cover entire wall before soffits are installed.
E150
ELEC, FINAL
IC
11/30/2007 03:23 PM RH PDA
E150
ELEC, FINAL
IC
Need plug to right of stove top and install gromet on
E150
ELEC, FINAL
IC
romex in w/h cabinet.
M110
MECH, FINAL
IC
September 11, 2007 8:00:33 AM acarter.
M110
MECH, FINAL
IC
Entered Wrong Inspection
M110
MECH, FINAL
IC
12/03/2007 03:05 PM RH PDA
M110
MECH, FINAL
IC
Need to complete vent -a -hood -duct.
Page 1
PREPARED 12/05/07, 7:59:02 INSPECTION TICKET PAGE 4
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 12/04/07
_ --_---_-_--_--------------------------------------------------------------
ADDRESS 2402 STONE CASTLE CIR j SUBDIV: CASTLEGATE PH 1 SEC 7
CONTRACTOR PITCOCK & CROIX PHONE (979) 764-7551
OWNER . . PHONE
PARCEL . . 184200-1710-0100
APPL NUMBER: 07-00002096 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 8/03/07 RH BLDG, FOUNDATION -SLAB TIME: 17:00
8/03/07 AP August 3, 2007 3:01:43 PM glsouth.
08/03/2007 04:36 PM RH PDA
Strings up, slab ground installed.
B115 01 9/11/07 JGM BLDG, FRAMING TIME: 17:00
9/11/07 AE September 10, 2007 9:46:47 AM glsouth.
09/11/2007 12:48 PM JGM PDA
need interior anchors and bracing behind fireplace
B130 01 9/13/07 RH BLDG, INSULATION TIME: 17:00
9/13/07 AE September 12, 2007 1:40:46 PM kwolfe.
09/13/2007 11:42 AM RH PDA
Before brick repair TYVEK. Tape seal around doors,
penetrations and seams. Foam sealant doesn't pass as a
moisture barrier as per Tyvek. Also, in the future TYVEK
must cover entire wall before soffits are installed.
B125 01 12/03/07 RH BLDG, FINAL TIME: 17:00
12/03/07 DA December 3, 2007 11:06:52 AM glsouth.
12/03/2007 03:07 PM RH PDA
Need to finish installing electrical plug to right of
stove top. Need to install address, handrails and post
energy requirements in electrical panel door.
B125 02 12/04/07 BI BLDG, FINAL TIME: 17:00
� December 4, 2007 2:29:23 PM acarter.
----------------------(-------------- CONTINUED ONTONEXT PAGE -----------------------------------
PREPARED
12/05/07, 7:59:02
INSPECTION TICKET PAGE 5
City of
------------------------------------------------------------------------------------------------
College Station
INSPECTOR: BUILDING INSPECTOR DATE 12/04/07
ADDRESS
. : 2402 STONE CASTLE
CIR SUBDIV: CASTLEGATE PH 1 SEC 7
CONTRACTOR
PITCOCK & CROIX
PHONE (979) 764-7551
OWNER .
.
PHONE
PARCEL .
. : 184200-1710-0100
APPL NUMBER: 07-00002096 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT:
MECH 00 MECHANICAL PERMIT SUB: CLIMATE MASTERS (979)775-6572
REQUESTED INSP
DESCRIPTION
TYP/SQ
COMPLETED RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
M110 O1
9/10/07 BI
MECH, FINAL TIME: 17:00
9/11/07 CA
September 10, 2007 4:39:58 PM acarter.
September 11, 2007 8:00:33 AM acarter.
Entered Wrong Inspection
M100 01
9/11/07 JGM
MECH, ROUGH IN TIME: 17:00
9/11/07 AP
September 11, 2007 8:00:51 AM acarter.
M110 02
12/03/07 RH
MECH, FINAL TIME: 17:00
12/03/07 DA
December 3, 2007 11:17:07 AM kwolfe.
12/03/2007 03:05 PM RH PDA
Need to complete vent -a -hood -duct.
M110 03
12/04/07 BI
MECH, FINAL TIME: 17:00
' ��-V% ,,,/
December 4, 2007 3:18:11 PM acarter.
--------------------------------------
COMMENTS AND NOTES--------------------------------------
WFO933747 / 001 City of College Station
PAGE 1
REQ. DATE: 07/24/07 07/24/07 12:37:44
LOCATION: 2402 STONE CASTLE CIR LOC ID: 208130
REQUESTOR: PITCOCK & CROIX �-- ''� ORIGIN: CUSTOMER -WALK IN
REQ USER: GLSOUTH AUTH USER:GLSOUTH WRK TYPE:
4" SEWER TAP AND 3/4" WATER TAP
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 07/24/07 SCHED COMPLETION: 07/24/07
********************************************************************************
JOB ORDER RESULT COf4MEPTrS
. ,li _ f �i i . _. �
Dec'06 2007 2:52PM RANDALL PITCOCK 9796935400 P.3
no
TEXAS SPCS TERMITE TREATMENT DISCLOSURE DOCUMENT
Location to be Treated:
Approximate Measures to be Treated: I`'
A LABEL FOR ANY OTHER PESTICIDE RECOWNDED OR USED HAS BEEN ATTACHED AS PART OF THIS DOCUMENT. WARRANTY INFORMATION (IF ANY)
INCLUDING AREA COVERED, TIME PERIOD OF WARRANTY, RENEWAL OPTIONSAND COST, THE OSUGAT7ON8 OF THE PEST CONTROL OPERATOR TO RE-
TREAT FOR TERMITE INFESTATIONS OR REPAIR DAMAGE CAUSED BY TERMITE INFESTATIONS WITHIN THE WARRANTY PERIOD, AND THE CONDITIONS THAT
COULD DEVELOP AS A RESULT OF THE OWNER'S ACTION OR INACTION THAT WOULD VOID THE WARRANTY HAS ALSO BEEN ATTACHED.
Charges for pre -treat:
NOTES: Annual re-newal:
",y's:•l;',�s(gut,�4y'y+rya,�f';.�{,'y�`.. r'- arr..y;,,k,��:_
N t
j. rpr'�?F...ky.,,�;=M1 Yi•' Xis"?;�jit,x�1 ,�y�
¢: K'$'!"ru•�,. 2n✓:+:.?4`d.i�;:us+�. :.S'��,+:v:�:+?iv, i.s�:::atr;ti7
Ca of Tochhulan M CB liewme 0 32120 I T
Dec 06 2007 2:52PM RANDALL PITCOCK 9796935400 p-2
er .
SUBTEI(iRAI`IEAN TERMITE`P:RECONSTRUCTION
1HSCLO' S.UiRRE FOR, ,EACH.FSTIMATE
For all treatrrients there will be a diagram showing exactly what.will be treated prior to e beginning of
fil
treatment. Review the .pesticide Labet provided to you.at this time for ininimum treatment standards.
Remember thaYyour:anchitects or design engineers specifications..must also be followed, unless they are
in violation of the law'. R$v%iew the eonsilmer In rmation.sheet for further information. If you have any
questions, contact the pest :control.company: or i e Texas
.Structural Pest Control Board; PO Box 1-927,
Austin, Texas 78767-1927. Tel `one:number(:12) 305=8250. ,.:
Name of Customer.
Address
Ci777-7
ty State Zip
Location to be Treated
Type of Treatment: [ ] .Full [ artial
A label of termiticide(s) is enclosed.
The percentage of the. termiticide(s) to be, �app;lied -at this location is ' OG a
Warranty Irifor on. provided >'niist lne?ude, t xe:Co l to Details of any Warranty provided and the
fvllo►ving: Time Periiad of War► e0 1 O&W41Optsons and -C.00; and Obfigat ons of the Contracting
Parties.
If the warranty does .not include t}te, entire,:stmeture treated; the areas included in the warranty are:
(spec%fy) .
Total Square Feet to be Treated:Total.Lineai Feet to be Treated:
Approximate Measurementsof the Structure(s)..to ; Treated: ti
w �
F0,07
Signature of Certtfied .AppiCM'DT Or' Fr rated. lame Date
Technician Completing Estimate .
Name of Pest Control Company TFCL. No.
Lize And iegulafedonder: eTezae $tsti tura! Pest Control Act'
Texas Structural Pest Control Board, PO Bog 1927, Auet n, Tea ' U7. 67-1927, Telephone number (512) 305.5250.
Sample Form — April 4, 2005 Page 1 of 2
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE, CATION, TX 77840
PHONE: (979) 764-357 FAX: (979) 764-3496
http://bpinspect-.Cstx.gov
----------------------------------------------------------------------------
Application Number . . . . . 07-00002096 Date 7/24/07
Application pin number . . . 958784
Property Address . . . . . . 2402 STONE CASTLE CIR
Property ID: 184200-1710-0100
R #•
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . CASTLEGATE PH 1 SEC 7
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . PLANNED DEVL HOUSING
Application valuation . . . . 140514
Owner
Contractor
-- - - - - - - - - - - - - - - - - -
- - - -- -----------------
PITCOCK & CROIX
-------
P.O. BOX 10276
COLLEGE STATION
TX 77842
(979) 764-7551
--- Structure Information
000 000 SINGLE FAMILY
Construction Type .
. . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . .
. . . . RESIDENTIAL-SFR/DUPLEX
Other struct info .
. . . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
2129.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
3.00
NUMBER OF BEDROOMS
3.00
SEWER TYPE
PUBLIC
TAZ
441.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
BK
Permit pin number .
515197
Permit Fee . . . .
583.00 Plan Check Fee
.00
Issue Date . . . .
7/24/07 Valuation . .
. . 140514
Expiration Date . .
1/20/08
Qty Unit Charge Per Extension
BASE FEE 460.00
41.00 3.0000 THOU BLDG, VAL 100001-500000 123.00
----------------------------------------------------------------------------
Special Notes and Comments
-Future Bonus Room Not To Include Future Electrical Wiring.
A J-box is Allowed for future Expansion but no Wall or
-
--------------- ----- ------------------------ ----- --- ----- -----------
BUILDING DEPTREPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764,-3576' FAX: (979)764-3496
http://bpinsp6ct.cstx.gov
Application Number 07-00002096
Application pin number 958784
Page 2
Date 7/24/07
Special Notes and Comments
Ceiling Wiring Allowed.
-Narrow Wall Bracing Fully Sheathed with Interior Anchors
and Bracing Behind Fireplace for Rear Porch Wall.
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTERS)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED
IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE
ISSUED.
Garage ceiling must have 5/8" Type X sheetrock when there
is Habitable space above the garage.
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3576 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 07-00002096
Application pin number . . . 958784
Page 3
Date 7/24/07
Special Notes and Comments
PENETRATIONS SEALED
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED IN
ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING
CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A
MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM
ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING
IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
A Minimum of No. 15 Asphalt Felt or Other Approved Water
Resisitive Barrier Shall be Placed Over All Exterior
Sheathing Per 2006 IRC Section R703.2
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2006 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 150-. of the gross area of exterior walls, R-8 duct
insulation is required. As an alterna ive, R-6 duct
----------------------- ---- ----i� -- -------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3576 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 4
Application Number 07-00002096 Date 7/24/07
Application pin number . . . 958784
----------------------------------------------------------------------------
Special Notes and Comments
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO
GLAZING RATIO UP TO 2001 A .40 OR LOWER FACTOR AND ABOVE 200
TO 30% A .35 FACTO OR LOWER SHALL BE MET.
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
STAIRS SHALL COMPLY WITH SECTION R-311 (2006 IRC) WITH A
CONTINUOUS HANDRAIL OR SECTION
1009 (2006 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL
NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A
NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND
LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003
IRC)
RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC
-----------------------------------------Ji--------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764'-3576 . FAX,: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page
5
Application Number
07-00002096 Date
7/24/07
Application pin number
----------------------------------------------------------------------------
958784
Special Notes and Comments
IF AN OPERABLE WINDOW IS MORE
THAN 72" ABOVE EXTERIOR
FINISHED GRADE THEN THE LOWEST
PART OF THE WINDOW OPENING
MUST BE AT LEAST 24" ABOVE THE
FINSHED FLOOR FROM INSIDE THE
ROOM.
ALL PLUMBING, ELECTRICAL, AND
HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS
PRIOR TO COVERING ANY WORK
----------------------------------------------------------------------------
Other Fees . . . . . . . . .
SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary Charged
---------------------------
Paid Credited Due
----------
Permit Fee Total 583.00
--------------------
583.00 .00
.00
Plan Check Total .00
.00 .00
.00
Other Fee Total 750.00
750.00 .00
.00
Grand Total 1333.00
1333.00 .00
.00
----------------------------------- - - - - -- vI--- --- --- - --�--------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number 07-00002097 Date 7/24/07
Application pin number . . . 043688
Property Address . . . . . . 2402 STONE CASTLE CIR
Property ID: 184200-1710-0100
R #•
Application type description TEMP POLE
Subdivision Name . . . . . . CASTLEGATE PH 1 SEC 7
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . PLANNED DEVL HOUSING
Application valuation . . . . 0
Owner
Contractor
------------------------
------------------------
PITCOCK & CROIX
P.O. BOX 10276
COLLEGE STATION
TX 77842
(979) 764-7551
----------------------------------------------------------------------------
Permit . . . . .
. TEMP POLE
PERMIT
Additional desc .
. BK
Permit pin number
. 515205
Permit Fee . . .
. 20.00
Issue Date . . .
. 7/24/07
Valuation . . .
. 0
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary
-----------------
Charged
----------
Paid Credited
----------
Due
Permit Fee Total
20.00
--------------------
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
co
CITY OF COLLEGE STATION
PlanningdDa IepmrntSendm
APPLICATION FOR BUILDING PERMIT
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840 '
(979) 764-3570 (979) 764-3496 FAX
W W W.CSTX.GOV
ADDRESS/LOCATION: 24C Stone Castle Circle
LOT v BLOCK _1 /SUBDIVISION
For Oft& U:0*
DATE:�I�CC RE'G
APPLICATION # )V90
TEMP POLE #t —o t 7
CASTLEGATE SEC/PH_7/1
BUSINESS/OWNER NAME: PHONE:979/764-7551
CONTRACTOR/HOMEOWNER: _Randall W Pitcock PHONE:979/764-7551
CONTACT PERSON FOR REVIEW COMMENTS: _Randall W Pitcock PHONE:979/571-7774
FAX: _979/693-5400 EMAIL:_RANDALL@PITCOCKHOMES.COM
ELECTRICIAN: M & M Electric PLUMBER: Ronnie West Plumbing
HVAC: Climate Masters " GOOD CENTS (Residential only):
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION " SLAB ONLY
DUPLEX (Landscape Plans) REMODEURENOVATION• SWIMMING POOL
TENT/CANOPY
DESCRIPTION OF WORK: New single family residence
PROPOSED USE: Residence
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: Yes
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $140514.00
o� (Cost of Labor and Materials)
nX PUBLIC SEWER
SEPTIc1TREATMENT SYSTEM
SEWER TAP:
❑X WATER TAP:
01
OTHER TAP:
ZE� TEMP POLE
4" SIZE
g/ n
SIZE
SIZE
TOTAL AREA:2566
NUMBER OF BEDROOMS:
HEATED AREA: 2129
3
NUMBER OF BATHROOMS: 3
�./�E TYPE: SINGLE F DOUBLE FX II%
ni
ATTACHED DETACHED CA PORT PV %
IGNATURE OF APPLICANT: '4p�e
"If proposed work involves new comrfiercial corfstruction 6r fadade improvemeffg/renovations to an ex
commercial property, building elevations are required.
Official Use Only
Plans Examiner Zoning Official y�ire Ma all
rj.�T,,,1dG Comments: — AWLIWf
&e R,mvr &-/�e Jry co.) Ab -rA4 I # w4d Rmt�k btlll�:5; I
... - ti
Energy Code Compliance Information
% Glazing of exterior walls 13.7%
Insulation R value of exterior walls 13
Insulation R value of ceiling 1 (flat areas) 30
Insulation R value of ceiling 2 (vaulted areas/no attic) 30
Glazing SHGC (Solar Heat Gain Coefficient) .36
Glazing U-Factor .60
R value of ductwork 6 /
A/C SEER Rating 13
Protection Against Subterranean Termites
x Chemical Termiticide Treatment (Soil Treatment)
❑ Chemical Termiticide Treatment (Field Applied Wood Treatment)
❑ Physical Barriers
❑ Other
*Verification of Application shall be submitted to the City of College Station
Building Department prior to issuance of the Certificate of Occupancy.
'w
PLAN -REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# D -"7 `
DATE: ,7
BUILDING ADDRESS:
I. Foundation Requirements- Minimum City Foundation Standards
N
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F.
Wood foundation details indicated
p
II. Framing: Floor, Wall, Ceiling and Roof Requirements
N
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
K
1. One -hour rated extending to roof deck
N OK
E.
Header sizes indicated on plans
N
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
1
,PLANS REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
III. Stairway Requirements
K
Q A./OK
A. Stairway Details
N
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
NA/019
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
INA�r
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
PLAN -REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
N K
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N K
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
N K
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
IN
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
N
Does not block any water course or divert any flow
Elevation certificate needed
K
"APPROVED PLANS PER IRC SECTION R106.3.1."
L S EXAMINER
`� - f 3 -01