HomeMy WebLinkAboutRES2007-02085,_ Z 1
PREPARED 4/04/08, 8:05:19 INSPECTION TICKET PAGE 1
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 4/03/08
------------------------------------------------------------------------------------------------
ADDRESS . : 4916 WHISTLING STRAITS LOOP SUBDIV: PEBBLE CREEK
CONTRACTOR ELLIS CUSTOM HOMES, LLC PHONE (979) 695-8394
OWNER PEBBLE CREEK DEVELOPMENT CO PHONE
PARCEL 497900-0039-0200
APPL NUMBER: 07-00002085 RESIDENTIAL, 1 UNIT DETACHED NEW
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
B100 01 8/07/07
8/07/07
B115 01 10/30/07
10/31/07
B130 �)1 11/07/07
11/07/07
B125 01 3/31/08
3/31/08
RH BLDG, FOUNDATION -SLAB TIME: 17:00
AP August 7, 2007 9:10:51 AM acarter.
08/07/2007 03:55 PM RH PDA
Strings up, slab ground installed.
OC BLDG, FRAMING TIME: 17:00
AE October 25, 2007 10:19:07 AM acarter.
friday afternoon please
10/31/2007 08:33 AM OC PDA
check with Terri Borisky about apa framing. check for hold
down brackets on sheer walls per drawing .
OC BLDG, INSULATION TIME: 17:00
AP November 6, 2007 4:44:56 PM glsouth.
November 7, 2007 11:23:20 AMkwolfe.
RH BLDG, FINAL TIME: 17:00
DA March 28, 2008 1:35:35 PM acarter.
MONDAY MORNING PLEASE CALL JOHN FRENCH @ 229-0108
HEAD OUT THERE. THANKS.
March 31, 2008 11:56:31 AM kwolfe.
e handrail a ron porc
nee'd- -a44T- n hrniaa n 2 1 de r =-boX
need engineered drawings and permit fo landscapig
wall
ous an r aii�'
BEFORE YOU=
retaining
B125 02 4/03/08 BI BLDG, FINAL TIME: 17:00
April 3, 2008 4:32:47 PM acarter.
-------------------------------------- COMMENTS AND NOTES --------------- ----------------
70A
Date: 4/4/2008
Inspection Comments for Final,
Permit Year: 7 permit Number: 208`
Address: 4916 WHISTLING STRAITS LOOP
Type
inspection Type Code Description
status
Inspection Result Comments
B100
BLDG, FOUNDATION-SV
IC
08/07/2007 03:55 PM RH PDA
B100
BLDG, FOUNDATION-SL
IC
Strings up, slab ground installed.
13115
BLDG, FRAMING
IC
10/31/2007 08:33 AM OC PDA
B115
BLDG, FRAMING
IC
check with Terri Borisky about apa framing. check for hold
B115
BLDG, FRAMING
IC
down brackets on sheer walls per drawing .
B125
BLDG, FINAL
IC
March 31, 2008 11:56:31 AM kwolfe.
B125
BLDG, FINAL
IC
need handrail at front porch
B125
BLDG, FINAL
IC
need address on house or 2 sides of mailbox
B125
BLDG, FINAL
IC
need engineered drawings and permit fo landscapig
B125
BLDG, FINAL .
IC
wall
B125
BLDG, FINAL
IC
need continous handrail for stairs
B125
BLDG, FINAL
IC
need combustion air for laundry room (cap gas valve)
B125
BLDG, FINAL
IC
need proper depth for insulatin and post indicators
B125
BLDG, FINAL
IC
post energy requirements in electrical panel
B130
BLDG, INSULATION
IC
November 7, 2007 11:23:20 AM kwolfe.
E110
ELEC, ROUGH IN
IC
November 1, 2007 4:52:32 PM kwolfe.
M100
MECH, ROUGH IN
IC
10/25/2007 04:11 PM RH PDA
M100
MECH, ROUGH IN
IC
Furnace flues need a min. 1" of clearances from
M100
MECH, ROUGH IN
IC
combustibles. Screws in flues shall be 1/4" max in lenght.
P105
PLBG, TOP OUT
IC
October 31, 2007 8:17:25 AM acarter.
P125
PLBG, FINAL
IC
March 18, 2008 11:27:28 AM glsouth.
P125
PLBG, FINAL IIC
IMarch 20, 2008 3:51:32 PM kwolfe.
Page 1
Date: 3/31 /2008
Inspection Comments for Final,
Permit Year: 7 permit Number: 208E
Address: 4916 WHISTLING STRAITS LOOP
Type
Inspection Type Code
Description
p.
status
Inspection Result Comments
B100
BLDG, FOUNDATION-SL,
IC
08/07/2007 03:55 PM RH PDA
B100
BLDG, FOUNDATION-SV
IC
Strings up, slab ground installed.
13115
BLDG, FRAMING
IC
10/31/2007 08:33 AM OC PDA
B115
BLDG, FRAMING
IC
check with Terri Borisky about apa framing. check for hold
B115
BLDG, FRAMING
IC
down brackets on sheer walls per drawing .
B130
BLDG, INSULATION
IC
November 7, 2007 11:23:20 AM kwolfe.
E110
ELEC, ROUGH IN
IC
November 1, 2007 4:52:32 PM kwolfe.
M100
MECH, ROUGH IN
IC
10/25/2007 04:11 PM RH PDA
M100
MECH, ROUGH IN
IC
Furnace flues need a min. 1" of clearances from
M100
MECH, ROUGH IN
IC
combustibles. Screws in flues shall be 1/4" max in lenght.
P105
PLBG, TOP OUT
IC
October 31, 2007 8:17:25 AM acarter.
P125
PLBG, FINAL
IC
March 18, 2008 11:27:28 AM glsouth.
P125
PLBG, FINAL
IIC IMarch
20, 2008 3:51:32 PM kwolfe.
Page 1
t.
WF1008759 / 001 City of College Station PAGE 1
REQ. DATE: 02/28/08 1' 02/28/08 9:50:11
LOCATION: 4916 WHISTLING STRAITS LOOP LOC ID: 201346
REQUESTOR: ELLIS CUSTOM HOMES ORIGIN: CUSTOMER -WALK IN
REQ USER: GLSOUTH AUTH USER:GLSOUTH WRK TYPE:
1" IRRIGATION
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 02/28/08 SCHED COMPLETION: 02/28/08
********************************************************************************
JOB ORDER RESULT CON14ENTTS
C
October 31, 2007
Mr. Keith Ellis
Ellis Custom Homes, Inc.
1507 Andover
College Station, Texas 77845
Re: Braced Wall Modification
Proposed Turgeon Residence
4916 Whistling Straits
Pebble Creek Subdivision
College Station, Texas
Job No.: 07-0247 �7�2085�
Dear Mr. Ellis:
akae..u-
Gessner
Engineering
Gessner Engineering was requested to inspect the braced wall layout for the for the
proposed Turgeon residence. According to the IRC section R403.1.6 interior braced wall
panels can be anchor to the foundation with nails. Exterior walls however, must be
anchored to the foundation with %" anchor bolts spaced at a maximum of six (6) feet.
The braced wall line which is located at the family room and extends through the two (2)
car garage located at the front of the residence has been moved to extend from the left
wall of the utility room and extend through the two (2) car garage located on the west side
of the residence. A braced wall shall be located in the utility room and along the stairwell
wall in the two (2) car garage.
Gessner Engineering advised onsite personnel of the foundation deficiencies. If you have
any questions with respect to this letter, please contact me.
�Si�nncerely,
JAA-
Thomas E. Gessner, P.E.
..v EOFT Y
....................
THOMAS E. GESSNER
iv 90967
9 c� • •:: : •'
qOQ S�ONAL �N®
Matthew W. Cowen, E.I.T.
1712 Southwest Parkway, Suite #105, College Station, Texas 77840 • P.O. Box 10763, 77842-0763 • 979.680.8840 • FAX 979.680.8841
2204 South Chappell Hill Street, Brenham, Texas 77833 • 979.836.6855 • FAX 979.836.6847
www.GessnerEngineering.com
TEMPORARY POLE PERMIT r/
CITY OF COLLEGE STATION V�
1101,,.,TZ4S' AVE n
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496 ,
----------------------------------------------------------------------------
Application Number
Application pin number . . .
Property Address . . . . . .
Property ID:
R #.
Application type description
Subdivision Name . . . . . .
Property Use . . . . . .
Property Zoning . . . . . . .
Application valuation
07-00002113 Date 7/18/07
085955.
4916 WHISTLING STRAITS LOOP
497900-0039-0200
R301272
TEMP POLE
PEBBLE CREEK
RESIDENTIAL
SINGLE FAMILY RESIDENTIAL
0
Owner Contractor
PEBBLE CREEK DEVELOPMENT CO
ELLIS CUSTOM HOMES,
LLC
ATTN: DAVIS YOUNG
9201 LAKE FOREST CT
N
4500 PEBBLE CREEK
PKWY
COLLEGE STATION
TX 77845
COLLEGE STATION
TX 778458942
(979) 695-8394
----------------------------------------------------------------------------
Permit . . . . .
. TEMP POLE
PERMIT
Additional desc .
KW
Permit pin number
513978
Permit Fee . . .
. 20.00
Issue Date . . .
. 7/18/07
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
TEMP ELECT POLE CONNECT
45.60
----------------------------------------------------------------------------
Fee summary
Charged
----------
Paid Credited
--------------------
Due
-----------------
Permit Fee Total
20.00
----------
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
-------------------
BUILDING DE
APPLICANT:
WF0929977 / 001 City of_.qoll•e4e Station PAGE 1
REQ. DATE: 07/18/07 07/18/07 9:20:36
LOCATION: 4916 WHISTLING STRAITS LOOP LOC ID: 201346
REQUESTOR: ELLIS CUSTOM HOMES ORIGIN: CUSTOMER -WALK IN
REQ USER: GLSOUTH AUTH USER:GLSOUTH WRK TYPE:
SWR 4" WTR 3/4"
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 07/18/07 SCHED COMPLETION: 07/18/07
********************************************************************************
JOB ORDER RESULT COMMENTS
(4/4/2008) Kim Wolfe Re: Calling for CEO @ 4916 Wh stling§traits Loop m mm mmT Page 1
From: Terry Boriskie
To: Amber Carter; Benjamin McCarty; Chris Haver; Gina Southerland; Joe G...
Date: 4/4/2008 2:17 PM
Subject: Re: Calling for C.O. @ 4916 Whistling Straits Loop
Contacted Cheryl at 204-0779 with Ellis Homes.
Terry Boriskie
City of College Station
Residential Plans Examiner
Ofc.979-764-3744 Fax 979-764-3496
> > > Joe Garcia 4/4/2008 2:09 pm > > >
NO FOR CO. SEWER BOX IS BROKEN, AND WILL NEED TO BE REPLACED. JMG
>>> Gina Southerland 04/04/08 8:15 AM >>>
BP# 07-2085
Gina Southerland
CSR - Planning & Development Services
City of College Station
979-764-3570
www.csb(.goy
Apr 04 2008 1:44PM 101 GROVE ST 979-764-7999 p.2
, TEXAS SPCB TERMITE TREATMENT DISCLOSURE DOCUMENT
....iW." "kiCt� J 'S 3j •'f4 :f�! ..L,':-�v�'n:j;''iSt:;�1J;;�'tQ{�
Proper Owner: fi5liFJ+...ly
A
Location to be Treated: `� ��r��.r/,��s� �j!T��•T ���}}f l'T7'':
-,
Approximate Measures to be Treated*w'640
Percentage of Termticide(s) to be applied at this location: 0.06
Type of Treatment: Full Partial XX Vertical XX
HorizontaWerimeter Beam XX
iEL FOR ANY OTHER PESTICIDE RECOMENDED OR USED HAS BEEN ATTACHED AS PART OF THIS DOCUMENT. WARRANTY INFORMATION (IF ANY)
'DidUDING AREA COVERED, TIME PERIOD OF WARRANTY, RENEWAL OPTIONSAND COST. THE OBLIGATIONS OF THE PEST CONTROL OPERATOR TO RE-
TREAT FOR TERMITE INFESTATIONS OR REPAIR DAMAGE CAUSED BY TERMITE INFESTATIONS WITHIN THE WARRANTY PERIOD, AND THE CONDITIONS THAT
COULD DEVELOP AS A RESULT OF THE OWNER'S ACTION OR INACTION THAT WOULD VOID THE WARRANTY HAS ALSO BEEN ATTACHED.
Charges for pre -treat:
NOTES: Annual re-newal:
,. <_;ti'N'�;c:F`s'r;aE'•",�"-`:€Ted' s%'f`�-
..... .. •�+�`.�w,psi:........i`+v�.t:ss�'�i.��Li'i}:,. ��c�`L;,i
v..... .,f,....:.. ..: � ,car--e•ti ;a-- s
Ca or Teddndm SPCB Hcanm 0 32129PT
Apr 04 2008 1:44PM 101 GROVE ST 979-764-7999 p.3
ACE PEST CONTROL
PO BOX 447.4
BRYAN, TX 77805
(979) $23-7777
TFCL 7120 PT
LIMITATIONS OF LIABILITY
1. ACE PEST CONTROL'S liability for additional treatment of the covered property is
limited to areas of infestation to the structure(s) which occur during the term of this
agreement (with the restrictions of the chemical label).
2. ACE PEST CONTROL shall not be liable for property that has been added to or
structurally altered unless ACE PEST CONTROL has been notified prior to the
beginning of any additions or alterations, and any additional treatment or re -treatment
found necessary is performed. Such additional treatment must be performed by ACE
PEST CONTROL at the expense of the owner.
3. ACE PEST CONTROL shall have no liability under this agreement should the
customer refuse access to the covered premises of any additions for the purpose of
carrying out the terms and conditions of the agreement.
4. ACE PEST CONTROL shall not be liable for re -treatment of subterranean termite
infestation caused by ABNORMAL moisture conditions such as leaky Toofs, shower
stalls, plumbing, or wet soil under the structure due to poor ventilation.
5. This service agreement does not guarantee against present or future damage to
property or contents, nor provide for repairs or compensation therefore. This service
agreement is for subterranean termites only, and does not include treatment for dry -
wood termites, carpenter ants, powder post beetles, or other wood destroying insects.
6. ACE PEST CONTROL shall not be liable for re -treatments of subterranean termites
caused by excess wood left around the foundation. For example: wood forms,
railroad ties, or any excess wood forms left in tub drains.
Licensed and regulated by the
Structural Pest Control Board
P.O. Box 1927
Austin, Texas 78767-1927
(512) 305-8250
Apr 04 2008 1:44PM 101 GROVE ST 979-764-7999
p.4
ACE PEST CONTROL
T.P.CJ,. # 7120 PT
PO BOX 4474
BRYAN, TX 77805
(979) 823-7777
(979) 774-4736
CERTIFICATE
The following property 49I6 WHISTLING STRAITS
built by ELLIS CUSTOM HOMES State of Texas
County of BRA WS the city of COLLEGE STATION
Mailing Address SAME , Zip code 77845
was treated for subterranean termites on this day JULY 29, 2007 and has met with
approval. Cost of initial treatment, $972.63, is payable upon completion of work. The
treatment is guaranteed for 12 months from the date of treatment. Thereafter, this
contract is subject to annual renewal (OPTIONAL) upon payment of annual inspection
and renewal fee of _J_1 plus tax, for a period of 4 years. ( see attached letter ) If
at any time during this contract a reinfestation of subterranean termites should occur, the
above said property will be treated at no additional cost to the owner. ACE PEST
CONTROL does not accept any liability for any subterranean termite damage repair.
Failure to pay the annual renewal fee within thirty days after the inspection date shall be
construed as a cancellation of this contract. Any alteration or addition to the foundation
of the above described property without proper termite treatment by ACE PEST
CONTROL Services shall nullify this contract.
Licensed and regulated by
Structural Pest Control Board
P.O. BOX 1927
Austin, TX 78767-1927
(512) 305-8250
Apr 04 2008 1:44PM 101 GROVE ST 979-764-7999 p.5
CONSUMER INFORMATION SHEET
" The structural pest control industry is regulated by the Texas Structural Pest Control Board located at PO Box 1927,
Austin, TX 78767-1927. The Board licenses the businesses, certified applicators and technicians who perform structural
pest control work. Certified applicators and technicians must pass a written examination in order to receive their licenses.
Pesticides must be registered with the United States Environmental Protection Agency and the Texas Department of
Agriculture before they maybe used in Texas. Environmental Protection Agency registration is not a finding of product
safety. Pesticides are designed to kill or control pests. Your risk of harm depends upon the degree of your exposure and
your individual susceptibility.
Specific health and safety information varies between pesticides and types of exposures and is available on the label
information or MSDS sheet, which can be supplied to you upon request from the licensed applicator. Take precautions
when a treatment has been performed to avoid exposure to vulnerable individuals. Pesticides may be harmful if
swallowed, inhaled, or absorbed through the skin. Avoid breathing dust or spray mist and any unnecessary contact with
treated surfaces. If you desire specific information on precautions, refer to the pesticide label. The law requires that the
application procedures specified on the label be followed.
If you have questions about the application, contact the business or person making the application. If you suspect a
violation of the law regarding structural pest control, contact the Structural Pest Control Board. In case of a health
emergency, seek immediate medical attention.
Pest Control signs must be posted prior to treatment in many instances. The signs should be posted in an area of common
access at least 48 hours prior to treatment. The information sign will allow you to contact someone who can tell you what
pesticide is being used.
If you are contracting for pest control services due to a home solicitation, you have the right to cancel the contract within
72 hours. You may exercise this right by notifying the pest control company that you do not wish to receive their service.
For general information on pesticides contact the National Pesticide Telecommunications Network at 1-800-858-7378.
For information concerning structural pest control laws, contact the Structural Pest Control Board at (512) 305-8250.
For information concerning the formulation and registration of pesticides, contact the Texas Department of Agriculture at
(512) 463-7476.
For non -emergency health information relating to pesticides, contact Texas Department of Health (512) 458-7111.
REDUCED IMPACT SERVICE
In order to minimize the reliance on pesticides and reduce pest populations, a Reduced Impact Pest Control operator may
recommend that you consider the sanitation or physical alteration of your work place or residence. It is your
responsibility to follow those recommendations. Your pest control operator may or may not offer these services upon
request. A proper inspection will provide the information necessary for you to choose the method of pest control which
best suits your situation. Many pest problems can be solved without using pesticides.
This Reduced Impact Service will include an inspection report and treatment recommendations. You should review these
and keep a copy for your records. Your cooperation in following the recommendations made by your service provider is
essential to a reduced impact service program.
Pesticides may be used in a responsible and professional manner in a reduced impact pest control service. If you do not
want a specific pesticide used or any pesticides used at all, you must note this in writing on the contract prior to the
initiation of the service. If any specific pesticide or class of pesticides are not excluded, it may be used by the provider.
REQUIRED BY THE TEXAS STRUCTURAL PEST CONTROL BOARD
Revised 6/6/03 Page 1 of 1
Apr 04 2008 1:45PM
101 GROVE ST
979-764-7999
p.6
SUBTERRANEAN TERMITE PRECONSTRUCTION
DLSCLOSURE FOR RACH ESTIMATE
For all treatments there will be a diagram showing exactly what will be treated prior to the beginning of
treatment. Review the pesticide label provided to you at this time for minimum treatment standards.
Remember that your architects or design engineers specifications must also be followed, unless they are
in violation of the law. Review the consumer information sheet for further information. If you have any
questions, contact the pest control company or the Texas Structural Pest Control Board, PO Box 1927,
Austin, Texas 78767-192.7. Telephone number (512) 305-8250.
/1A ^ %: A a
Name of
Address
City QQ State zip -
Location Location to be Treated ji% �!/� �ah P � � C
Type of Treatment: [ ] Full
A label
ides) is enclosed.
The percentage of the termiticide(s) to be applied at this location is r e
Warranty Information provided must include the Complete Details of any Warranty provided and the
foRowing. Time Period of Warranty; Renewal Options and Cost; and Obligations of the Contracting
Pantie&
If the warranty does not include the entire structure treated, the areas included in the warranty are:
(specify)
Total Square Feet to be Treated: w Total Linear Feet to be Treated:
Approximate Measurements of the Nture(s) to be Treated:
Signature of Certified Applicator or Printed Name Date
Technician Compl ing Estimate
o / i /.-;,20'T
Name o Pest Control Company TPCL. No_
Licensed and regulated under the Texas Structural Pest Control Act
Texas Structural Pest Control Board, PU Box 1927, Austin, Texas 78767-1927, Telephone number (512) 305-8250.
Sample Form — Aprll 4, 2005 Page 1 of 2
- BUILP✓ERMIT
CITY OF 'COL.LEGE STI jTION
1101 TEXAS AVENUE, CO`LLEGE I -STATION, TX 77840
PHONE: (979)764-3570,. FAX: (979)764-3496
http://bpiri,spect.cstx.gov
----------------------------------------------------------------------------
Application Number . . . . . 07-00002085 Date 7/18/07
Application pin number . . . 973000
Property Address . . . . . . 4916 WHISTLING STRAITS LOOP
Property ID: 497900-0039-0200
R #: R301272
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . PEBBLE CREEK
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 459600
Owner Contractor
PEBBLE CREEK DEVELOPMENT CO ELLIS CUSTOM HOMES, LLC
ATTN: DAVIS YOUNG
9201 LAKE FOREST
CT N
4500 PEBBLE CREEK
PKWY COLLEGE STATION
TX 778.45
COLLEGE STATION
TX 778458942 (979) 695-8394
--- Structure Information 000 000 SINGLE FAMILY
Construction Type
. . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type .
. . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info
. . . . . EXTERIOR WALL TYPE
SIDING/BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
4.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
4596.00
INTERIOR WALL TYPE
DRYWALL
NUMBER OF BATHROOMS
5.00
NUMBER OF BEDROOMS
5.00
SEWER TYPE
PUBLIC
TAZ
419.00
----------------------------------------------------------------------------
Permit . . . . .
. BUILDING PERMIT
Additional desc .
. GS
Permit pin number
. 513713
Permit Fee . . .
. 1540.00 Plan Check Fee
.00
Issue Date . . .
. 7/18/07 Valuation . .
. . 459600
Expiration Date .
. 1/14/08
Qty Unit Charge Per
Extension
BASE FEE
460.00
360.00 3.0000 THOU BLDG, VAL 100001-500000
1080.00
----------------------------------------------------------------------------
Special Notes and
Comments
-Take note of required tempered fixed windows in family
-------------------
BUILDING DE
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE. STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number 07-00002085
Application pin number 973000
Special Notes and Comments
room.
Page 2
Date 7/18/07
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTERS)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED
IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE
ISSUED.
Garage ceiling must have 5/8" Type X sheetrock when there
is Habitable space above the garage.
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
-------------------------- ------ - - ----- -J-----------
BUILDING DEPT, jEPRESENTATe1-V`5: //
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 07-00002085
Application pin number . . . 973000
Page 3
Date 7/18/07
Special Notes and Comments
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED IN
ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING
CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A
MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM
ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING
IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
A Minimum of No. 15 Asphalt Felt or Other Approved Water
Resisitive Barrier Shall be Placed Over All Exterior
Sheathing Per 2006 IRC Section R703.2
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2006 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system} has a SEER rating
--------BUILDING DEPT,REPRESENTl _: /I// /,5. �9----------
APPLICANT:
BUILIDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpins'pect.cstx.gov
Application Number . . . . . 07-00002085
Application pin number . . . 973000
Special Notes and Comments
Page 4
Date 7/18/07
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO
GLAZING RATIO UP TO 20% A .40 OR LOWER FACTOR AND ABOVE 200
TO 30% A .35 FACTO OR LOWER SHALL BE MET.
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
STAIRS SHALL COMPLY WITH SECTION R-311 (2006 IRC) WITH A
CONTINUOUS HANDRAIL OR SECTION
1009 (2006 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL
NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A
NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND
LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003
IRC )
RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC
IF AN OPERABLE WINDOW IS MORE THAN 72" ABOVE EXTERIOR
----------------------- . --- ---- �-��----------
BUILDING DEPTJ I,EPR9SENTAq I�l�a �
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page
5
Application Number . . . . .
07-00002085
Date
7/18/07
Application pin number . . .
973000
----------------------------------------------------------------------------
Special Notes and Comments
FINISHED GRADE THEN THE LOWEST
PART OF THE WINDOW
OPENING
MUST BE AT LEAST 24" ABOVE THE
FINSHED FLOOR FROM
INSIDE THE
ROOM.
ALL PLUMBING, ELECTRICAL, AND
HVAC (mechanical) WORK
MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT
BUILDING
DEPARTMENT FOR INSPECTIONS
PRIOR TO COVERING ANY WORK
----------------------------------------------------------------------------
Other Fees . . . . . . . . .
SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary Charged
---------------------------
Paid Credited
--------------------
Due
----------
Permit Fee Total 1540.00
1540.00
.00
.00
Plan Check Total .00
.00
.00
.00
Other Fee Total 750.00
750.00
.00
.00
Grand Total 2290.00
2290.00
.00
.00
-----------------------JJ -- -----s ----- ------------
BUILDING DEPT 96RESANTAT�_ �//
APPLICANT:
APPLICATION FOR BUILDING PERMIT
1101 TEXAS AVENUE
(*hr4" COLLEGE STATION, TX 77840
CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX
Planning d Development Service:
CSTX.GOV I !
AD DRESS/LOCATION -F I I
LOT BLOCK --",SUBDIVISION
f For Once Use Only
DATE: t W jnRCC REG a Sy
APPLICATION # �-
TEMP POLE #
BUSINESS/OWNER NAME: 6/I15( (SS�M Holl'LCS PHONE: 1IGI-[-'o0LS_- E-3 I
CONTRACTOR/HOMEOWNER: + rv) // l.II� rr__ PHONE: 617°l
CONTACT PERSON FOR REVIEW COMMENTS: /�e i't�"I &11l S PHONE: LI-7q- /a9,5--SJ ( 1
FAX1179--7& -7q9 2 EMAIL:key A(iP_ej I (S ifua6mko44eS,
ELECTRICIAN: f%1eG7rr6 PLUMBER: ����l cr►'��lrllol
HVAC: d S `y' f GOOD CENTS (Residential only):
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey)L..--NEW CONSTRUCTION * SLAB ONLY
DUPLEX (Landscape Plans) REMODEURENOVATION* SWIMMING POOL
TENT/CANOPY
DESCRIPTION OF WORK: Till' GLI (�nSTf LcG�ha/1
PROPOSED USE: Jl'A G (2 �Gr►'l I
HOMEOWNER ASSOC IATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ -151 to o'D TOTAL AREA: &-J.�a HEATED AREA: 57'j G2
(Cost of Labor and Materials)
PUBLIC SEWER
SEPTIC/TREATMENT SYSTEM
SEWER TAP: ' 1
SIZE
WATER TAP:
314
SIZE
OTHER TAP:
SIZE
TEMP POLE
GARAGE TYPE:
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE:
nrq
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
Sl��
ROOF TYPE:
COM�npS 1 "h �/) Sl�Ao'e3
DOUBLE F�a TRIPLE
E::]
DETAC D CARPO
SIGNATURE OF APPLICANT:
*If proposed work involves new commercial construction or facade improvements/renovations to an existing
commercial property, building elevations are required.
Official Use Only
-j
!/ Plans Examiner
Z6�51 "dC4
-✓ -114 Flat wig 2Ar`felicit
SINGLE
ATTACHED DT
Zoning Official j'4(AteFire Marshall
ES r NO
�C
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC (Solar Heat Gain Coefficient)
Glazing U-Factor
R value of ductwork
A/C SEER Rating
Protection Against Subterranean Termites
11 Chemical Termiticide Treatment (Soil Treatment)
N 3&
❑ Chemical Termiticide Treatment (Field Applied Wood Treatment)
❑ Physical Barriers
❑ Other
*Verification of Application shall be submitted to the City of College Station
Building Department prior to issuance of the Certificate of Occupancy.
P
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# 07 _
DATE: _l 7 `�
BUILDING ADDRESS:
q � G✓��S�l.� s
I. Foundation Requirements- Minimum City Foundation Standards
NA/ K
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F.
Wood foundation details indicated
OK
ll. Framing: Floor, Wall, Ceiling and Roof Requirements
N
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
K
1. One -hour rated extending to roof deck
OK
E.
Header sizes indicated on plans
NAIM
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roofcovering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
III. StairwayRequirements
OK
OK
A. StairwayDetails
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
TJ
4. tairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
-
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch s here
IV. Fireplace Requirements
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
N
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
N
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units)
T
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
N
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Re uirements
NA/ K
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
NA/
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
N
Does not block any water course or divert any flow
Elevation certificate needed
&OK
"APPROVED PLANS PER IRC SECTION R106.3.1."
ANS EXAMINER
/7o'l
DATE