HomeMy WebLinkAboutRES2007-00561, 07-563p-►•6103 PREPARED 7/27/07, 8:06:50 INSPECTION TICKET PAGE 9 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 7/26/07 ------------------ ADDRESS ------------------------------------------------------------------------------ 907 TURTLE DOVE T R L SUBDIV: CONTRACTOR`:""CLASSIC CENTURY HOMES PHONE (817) 561-4369 OWNER . . . PHONE PARCEL . . : 230100-0207-0350 APPL NUMBER: 07-00000561 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDIIQG PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 4/12/07 RH BLDG, FOUNDATION -SLAB TIME: 17:00 4/12/07 AP April 11, 2007 3:36:03 PM glsouth. April 12, 2007 12:28:54 PM ncochran. strings up, slab ground installed B115 01 5/15/07 RH BLDG, FRAMING TIME: 17:00 5/15/07 DP May 15, 2007 10:20:12 AM kwolfe. 4 WINDOWS IN FRONT NEED TO BE REPLACED - WILL BE IN TOMORROW BY INSULATION 05/15/2007 04:22 PM RH PDA Need proper apa nailing. Add support for rafters above front window. Tighten nuts on steel panel. Seal all exterior seams. Complete fireplace flue.and have proper clearances. Loose electrical wires in front room. B115 02 5/21/07 OC BLDG, FRAMING TIME: 17:00 ' 5/21/07 AP May 21, 2007 10:52:49 AM acarter. B130 01 5/24/07 JGM BLDG, INSULATION TIME: 17:00 _, 5/24/07 AP May 23, 2007 11:52:30 AM acarter. B125 01 7 26/07 BI' BLDG, FINAL TIME: 17:00 July 26, 2007 1:43:16 PM acarter. ------------------------ t --------- CONTINUED ONTO NEXT PAGE ----------------------------------- Date: 7/27/2007 Inspection Comments for Finals Permit Year: 7 Permit Number: 561 Address: 907 TURTLEDOVE TRL Type Inspection Type Code Description status Inspection Result Comments B100 BLDG, FOUNDATION -SLAB IC April 12, 2007 12:28:54 PM ncochran. B100 BLDG, FOUNDATION -SLAB IC strings up, slab ground installed 13115 BLDG, FRAMING IC 05/15/2007 04:22 PM RH PDA B115 BLDG, FRAMING IC Need proper apa nailing. Add support for rafters above 13115 BLDG, FRAMING IC front window. Tighten nuts on steel panel. Seal all B115 BLDG, FRAMING IC exterior seams. Complete fireplace flue and have proper B115 BLDG, FRAMING IC clearances. Loose electrical wires in front room. P100 PLBG, ROUGH IN IC April 3, 2007 4:13:08 PM kwolfe. Page 1 WFO883973 / 001 City of College Station ^ G,�^1_n/� PAGE n 1 l / REQ. DATE: 03/27/07 03/27/07 11:44:46 LOCATION: 907 TURTLE DOVE TRL LOC ID: 204526 REQUESTOR: CLASSIC CENTURY HOMES ORIGIN: CUSTOMER -WALK IN JREQ USER: KWOLFE AUTH USER:KWOLFE WRK TYPE: TEMP POLE PASSED ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 03/27/07 SCHED COMPLETION: 03/27/07 ******************************************************************************** JOB ORDER RESULT COMVIMTS WF0882124 / 001 City of College Station PAGE 1 REQ. DATE: 03/20/07 03/20/07 14:16:02 LOCATION: 907 TURTLE DOVE TRL LOC ID: 204526 REQUESTOR: CLASSIC CENTURY HOMES ORIGIN: CUSTOMER -WALK IN REQ USER: GLSOUTH AUTH USER:GLSOUTH WRK TYPE: SWR 4" WTR 3/4" ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 03/20/07 SCHED COMPLETION: 03/20/07. ******************************************************************************** JOB ORDER RESULT COM14ENTS (7/31/2007) Gina Southerland Recalling forTCO for907 Turtle Dove Trl T Page 1 From: Terry Boriskie To: Amber Carter; Benjamin McCarty; Chris Haver; fredburris; Gina Southe... Date: 7/30/2007 1:39 PM Subject: Re: Calling for C.O. for 907 Turtle Dove Trl Contacted Fred Burris Terry Boriskie City of College Station Residential Plans Examiner 979-764-3744 >>> Paul Schoenfeld 7/30/2007 12:19 pm >>> Water ok. Sewer tied in with 905 buried. Paul >>> Amber Carter 7/27/2007 1:44 PM >>> by #07-561 'I, .4i' � Ewa tarry OFCOLLEGF S-1.010N ADDRESS/LOCATION: APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764 3496 FAX WWW.CsTX.Gov OATE3 -_SC_ REG APPLICATION # 01 • V5U TEMP POLE « V • �Y3 LOT 'dv_ OCK �," SUBDIVISION _ V 01{i Ck05S.t -) V `' SEC/PHW�� �+ BUSINESS/OWNER NAME: �.A461(, CL-Q7'Q(Z bl'j,&S PHONE: CONTRACTOR/HOMEOWNER: (LASS G G^�,GAC- SPHONE: CONTRACTOR ADDRESS: 10-0--jIA C(- 1,,r12 CA9 w 1.�&'T'07X _saa_S" ELECTRICIAN: PLUMBER: HVAC: _ _ _ GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION ` SLAB ONLY DUPLEX (Landscape Plans REMODEURENOVATION` SWIMMING POOL Required) DESCRIPTION OF WORK: jA,Ir Z., 0!! 1(/, W 6o STRUCTURE USE: HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: �V TEXAS ACCESSIBILITY STWAARD (TAS) PROJECT REGISTRATION# EABPRJ NA VA UAT.ION: $ s% v� • ✓ TOTAL AREA: ZOZZ HEATED AREA:j'�>� (� bor and Materials) — PUBLIC SEWER SEPTICfTREATMENT SYSTEM / If C.; SEWER TAP: WATER TAP: 3VErr SIZE OTHER TAP: GARAGE TYPE: SINGLE ATTACHED NUMBER OF BEDROOMS: 3 NUMBER OF BATHROOMS: j INTERIOR WALL TYPE:dOt� EXTERIOR WALL TYPE FOUNDATION TYPE: ROOF TYPE: DOUBLE _t TRIPLE CARPORT SIGNATURE OF APPLICANT: __— o `-� �_` 'If proposed work involves new co m ercial nstr ction or facade mp vements/renovations to an existing commercial property, building elevati ns are required. Official Use Only C 3-g-� /P Plans Examiner Zoning Official o ments. or NO 55.00' 1 ' P.U.E ----------------- 00 M� ONE STORY SINGLE FAMILY BRICK RESIDENCE PLAN # 1582 0 `t o `' 00 cli 71_7f' W-1 (1" 71_711 &L, 201 BL - 18' CONC. DRIVEWAY N - - - - - - - - - - - - - - - 5' P.U.E 55.00' 907 TURTLE DOVE TR LOT 35, BLOCK 7 PHASE 2 DOVE CROSSING SUBDIVISION COLLEGE STATION, BRAZOS CO. TX L7 VISES o� PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# _ 3-� DATE: 3 _ 2 ` O ,7 BUILDING ADDRESS: Qo vvfl� adz l . I. Foundation Requirements NA/ A. Concrete minimum f c of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier Emil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior, unless over 60' long must be 30" 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated OK II. Framing: Floor, Wall, Ceiling and Roof Requirements A/ A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex K 1. One -hour rated extending to roof deck OK E. Header sizes indicated on plans A/ F. Emergency bedroom egress 1. Exit direct to outside 2. O enable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. O enable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing 2. Moisture barrier indicated on plans 3. Exterior Wall Covering J. Roof framing plan or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size, spacing, roof slope & purlin bracing if required to reduces an O. Roof covering P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only S. All walls within 3' of property line to have protected openings. III. Stairway Requirements OK A. Stairway Details ('14Jq0 K 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8 B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than twenty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements to be indicated onplans)N A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must meet IRC Chapter 10 Requirements V. Electrical Service Requirements A. Electrical plan to include: N TI 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX VI. Plumbing Requirements A. Pressure reducing valve required when water pressure exceeds 80 psi N B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements NAJAW A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) VIII. Energy Requirements N A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 N Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements NAYOfO Maximum drive width for residence is 28' combined for circular Minimum 30 feet from driveway to side(intersecting) street Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 N Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 N Does not block any water course or divert any flow Elevation certificate needed "APPROVED PLANS PER IRC SECTION R106.3.1." J/4101 3-2-0. PLANS EXAMINER DATE T_ I ` Engineed.ng, LLC 401 S. CLAY STREET, ENN1S, TX 75119 February 19, 2007 Classic Century Homes 5001 Hwy. 287 South Arlington, TX 76017 The following post -tensioned foundation plans are herein authorized for construction at the address and legal description shown below. Lot Blk Subdivision Address CitV County State 35 7 Dove Crossing 907 Turtle Dove Tr. College Station Brazos TX A site specific soils report was not provided. The foundation has been designed based on the following soils conditions. Soils Laboratory Brazos County USDA Soils Survey Allowable Bearinq Pressure P.I. 1500 psf 52 The foundation design is in accordance with the applicable provisions of the International Building Code 2000/2003 Edition, the International Residential Code 2000/2003 Edition, the Design and Construction of Post - Tensioned Slabs -on -Ground, Second Edition, 1996 by the Post -Tensioned Institute, applicable provisions of the Building Research Advisory Board (BRAB) Publication 33, and accepted engineering practice. If you have any questions, please call me at 972-878-3647. PTF0207018 t o A A. M MENNA ea... ,i�'• 509n95o. �eq N 9F0�srt •C�' AL 211912007 A.G. (Tony) Medina Registered Professional Engineer PHONE: 972.878.ENGR (3647) - FAX: 972.875.1398 • E-MAIL: info@txfoundations.com DO' ROM TO SURROU NOTE: 1) SHADED WALLS TO 2" x 6" FOR PLUMBING 2) ALL HEADER HEIGHTS TO BE 6110" UNLESS OTHERWISE NOTED 3 PROVIDE TEMPERED GLASS WHERE NEEDED PLAN # 11582 IBSSIC Century Homes ADDRESS 907 TURTLE DOVE TR LOT 35 BLK 7 SUBDIVISION DOVE CROSSING aps les Electrical ceiling fan spotlights I Fluorescent Fixture o pot light i.L&.LL vanity bar light ® Iran light outlet outlet 220v outlet gfi ® smoke detector g switch g, switch 3 way .lW4 1) Lighting on stair to conect from switch o top to light mounted on wall 6 middle of stairs to switch io bottom of stairs per sec R303.4 2) Smoke detectors will be hard wired in series w/ battery backup power as per sec, R311 3) Provide 110 outlet 8 light near NVAG unit For service with switch, In•alFwnuNc ARDA 'TUB,q lr— RII BATTnmR IR'BYPIUM BOARD 2X4 BOMM FUTE GATT MSiMTUN NR:I' OF R W R wunEFRnmrtcnmxlnr. — 1•AR SPACE Irrs2osAnIPT AUBARaRR 2N STOD11? 16' ".. 111 BATTPSDIATLLIN 1?SIIERTROO: HETAtaRIIX nP� VP 1o'SHEAT'E n: AR aURRIEO OU05 R h1 A'2UM RS 16'0,.. RII BATTINSULAIpN IT SFIEET0.o(Y :xTw�naN Pura TRUTu1 TYPIUL nUURSYSTEM: JN'TRG SUBEWUR TRussvnLTHGMTnoIXNBs m BE aETpUnNTD DY Fl.TB.TFJt IMFIIgA CF1Ux0 PINlTH :2.. TO PTATEA 81 tUCRSESTUUATERSIDE OF 1100R)ue, j.WVEMEVERYADBAKER 0 earro, I IBOLTt;a OCNA%. of "sa 4 ALLRUB p1.1EN1WN11N1IXNEt1E1. a1 • .� RR1]NF'VRLTIiEMIUBl Otl1ARUNEJIBY FNGD?E0. '� TYPICAL ROOF • I1" SHINGLES RL "s-R mA PLYWOOD SHEATHING Gm 'H' CLIPS MIN. YX6" CONTINUOUS RAFTERS a 24" O.C. BATT INSULATION AIR VENT BAFFLES e24' D.C. ROOF PI END AT RIDGE TO BE INSTALLED 50 THAT AIR FLOW 15 NOT 1 (0VERHAN RESTRICTED DECKING MAX. WOOD FASCIA SOFFIT MATERIAL TYPICA_ BRICK EXTERIOR WALL FACE BRICK I° AIR SPACE I1' SHEATHING 2'H4' STUDS o 16" ..c. BATT INSULATION CITY OF LOCKHART 11' SHEETROCK TYPICAL ROOF OVERHANG DETAIL SNBiGLER CMTPTTRI AR VENEIMAI LOSS HA All FLOW IS NOTRESTINSTALLFD 50TNAT AIR f WA' I$ NDT RECIRICTED Rnx.lx6RA2TExa@2o'O.0 1MPLYA'VODSHFwTHING H(7UPS F. uu }. ROOn T M EOUAMY SPAM VENTS 0—c NETAL I RN%TIES I•ARSPAM Ic-SHERnOHG ARBARRIE 2N'runt w PC RI a—IA'SU M,I 2'SNEETROIX J ' '� ALLRIwB DDIFNRIDMTN2(]CNFSfF3. • �1, awxwRnalEaTroeEBLTlxwnv2aY RI �, A I. E'OINEE0. TOP VIEW CHIMNEY CAP LUE CHIMNEY 2X4 BAND CAP 2X4 BANE 2X4 FRAMRqVk- ; N MEMBER - 2� 4a - �— 2X4 FRAM MEMBER SIDE VIEW OSB — SIDING - TYPICAL WALL DETAILS NOTE: 1) Foundation anchor bolts at 60" o.c. as per 2000 IRC sec. R403.1.6 2) All framing and structural design to meet 90 m.p.h. wind criteria as per scc. R3011.1 and table R301.2(4) 2003 IRC code. 3) All lower sole plate to be Pressure treated as per sec. R323. All rasteners to be hot dipped galy. steel, stainless steel, silicon bronze or toper only as per sec. R323.3 4) Provide hand tails on all staiTs/sleps with a minimum of 2 risers as per sec. R315. (min. stair tread 10": mu. riser 7 3/4" sec. R314.2) 5) Masonary veneer anchorage of 24" horizontal and IS" vertical as SPHERE HOT PASS per sec. R703.7.4.1 and weep holes ate maximum of 33" o.c. as per HANDRAIL 1 IN' MIN. sec. R703.7.6. 111111111 ........................ ........To: St"' See. _____________________ I21 N_ UO X IN. TREAD IK U Qz A ¢� Q zt b a `- U P `g H W Fi STAIR DETAIL IRC 2003 �10' 0" MIN. MIN. Z_ I I I o I 1 I I100� N I Irl I I Fr1� I I � I I , I W I I 1 lI I Fr T-1 I I F+1 I I I I , t I SHALL RETURNENDSTO THRU 4" WALL OR POST o 18" FLOOR SYSTEM (3)2xl2 STRINGERS F 5/8" TYPE DRYWALL x UNDER STAIR STRINGERS a U ANDRAIL @ 34D-38" MAX. FIRST FLOOR C Century Homes Afaking He., ON'urship AJfordablr C Century Homes Afaking He., ON'urship AJfordablr Area Calculator: Assembly Type Description Window Area Total: 196.53 ill Area Calculator: Description Door Area Total: 55.56 02/01 /07 09:42:32 1 /1 BRICKLEDGE WHEN APPLICABLE 12k'B AR TIPH@ D' BRICKLEDGE WHEN r y}, 1"• /-BRICKLEDGE WHEN - / APPLICABLE 5' ' 'y LL CORNERS . • APPLICABLE SLAB STRAND i CHAIR WHEREAPPUCABLE CHAIR� SHION � U.- _ �^�I� SANDTYP. m�'���CUSHION IN 112-BSII DETAIL SAND, TYP. d' - - .-s- : -:) • " L l7? _ _ _ - _ _ c — - - !. • .1 _ _ .. ' I {.. }� ¢ r ..J_1 / : - ,m- ...r�SAND. TYP. . 6' . 6' ;L TOP OF - - POST -TENSION STRANDS p y _ TOP OF _- -- k -- (Ii POST -TENSION STRANDS GRADE - I' WHEN INDICATED "- oC I I,u- - ° ) °S° STRAND ), r~ c I F w O Z y' �ILI • • �- TOP OF .I POST -TENSION STRANDS ANCHOR GRADE - "y� WHEN INDICATED -, i ON PLAN, TYPICAL ¢ ° / . - ✓ I!I' .i ✓� ON PLAN, TYPICAL •.. 2• #5 EiAFl.S ¢ I •- �- GRADE J - ' WHEN INDICATED ¢ Tll-� '•.:.. CHAIR ON PLAN, TYPICAL Cn / DRAPE BEAM STRAND 8'.RAPE BEAM STRAND o II . P —I r / r DRAPE BEAM STRAND WHEN INDICATED ✓ WHEN INDICATED O T —� �; •• I WHEN INDICATED ON PLAN, TYPICAL, p N \ ON PLAN, TYPICAL #4 BARS•' N Q ON PLAN, TYPICAL p #3 SUPPORT STAKES VAPOR @ 12. 0.0 O UNDISTURBED 'BS'STRAND #3 SUPPORT STAKE T PI�CAL� , F PE DIMENSIONS E PLAN FOREACH WAY F SOIL GRADE ANCHOR • 2- 04 BARS VERTICALLY SLAB STRANDS DETAIL "A" DETAIL "Al" �' SPACED @1ro.c. As -FORM BOARD N REOUIRED PER BEAM DETAIL "E" el �, DEPTH CHAIR -�.-..-.,..ter.-..-...,�, NOTE: R Is IMPORTANT TO USE THIS DETAIL ) "' •/ r r BRICKLEDGE WHEN 44 VERTICAL WHEN THERE IS A 4'OR LESS SLOPE IN THE FOUNDATION FOOT PRINT AREA TO INSURE ¢ • ' ` SUPPORTS @B' 4ug t THAT SETTLEMENT DOES NOT OCCUR, THE 1- #4 BACK UP BAR O C BOTTOM PENETRATEF THE PERIMET URBED SOIL AMMIN O 17� L¢7- ,s STANDARD DEEPEN l JJJ TIEWRE CHAIR �-::,2���- '# °P''�E°° i-•� BEAM DETAIL �......�`.`..�.rt.��.� �LEISTIAN 'CHAIR '•CHAIR�CHAIR ���4' 3 STRANDS - sue STRANDS • - . • � ::, r � � . CHAIR LAYOUT _ "� SLAB STRANDS l . WHERE APPLICABLE • �.: :. -_ I•' WHERE APPLICABLE mr - � WHERE APPLICABLE °( BEAM STRAND}`'; 2- #5 BARS #4 BARS @ it O.C.E.W. APPLICABLE • �, WHEREBEAM STRAND J ° � DRAPE BEAM SLAB STRANDS . < � WHERE p .. ':9Y STRAND SHEATHING CUT BACK BEHIND ANCHOR APPLICABLE M #3 SUPPORT STAKE - � � � .I II ,, . � I I,�:I�Y`-" WHEN INDICATED ,'�� �. (CARE SHOULD BE TAKEN TO p H #3 SUPPORT STAKE � H 1/ ON PLAN, TYPICAL. .. ENSURE SHEATHING DOES NOT p Y/ ✓' '.i fyi)' CHAIR) T I .:.•�.. ,�\ g• PROTRUDE INTO THE ANCHOR) DETAIL "BII DETAIL IIB111 I STANDARD -`pF �'IS���;,;_ _�_Y���� .,. ,•M BRICKLEDGE WHBJ pPBRICKLEDGE WHEN OP I DETAIL "G" DROP DETAIL M BEAM 6° WOOD APPLCABLE Bn01'r APPLICABLE GE DPI, EXCAVATION a}f Tr / 3}, BRICKIEDGEWh1EN BRICKLEDGE TENDON INSTALLATION / APPLICABLE WHEN APPLICABLE � / r Z 1• 194 BACK UP BAR AT STRESSING -END 94 BARS @ 12- O.C.E.W. SIN `• / .�- - / .. _ _ 1• #4 BACK R BAR ,�� m SLAB STRAND CHAIR 6'. CHAIR y} "H a�j -CHAIR N ' ' ' POCKET TOP OF �.,• GRADE) SLAB STRANDS I, I'/ i. \ FORMER TOP OF / , j - � SLAB STRANDS ,qqq///� . • 0 r1.., 16- (12- MIN.) '. ,y WHERE APPLICABLE GRADE J WHERE APPLICABLE I SLAB STRANDS i roi �,.. WHERE APPLICABLE p CHAIR .� DRAPE BEAM STRAND 2- 05 BARS �� '�. •. •,� WHEN INDICATED •`a _ , - #4 BARS @ 17 I I -SLAB STRAND ON PLAN, TYPICAL DRAPE BEAM d O.C.E.W. II g CUT PLASTIC }yr STRAND TOP OF •, HERE N '` WHEN INDICATED GRADE) I+'IISTRANAPED 3'•0'MAX W \ EXCAVATON WOOD ON PLAN, TYPICAL"'i,•�'" •` WHEN INDICATED L -BEAM STRAND `FORM I. / 1. I� t' AS SPECIFIED ON PLAN, TYPICAL '%� 1� #4 FOR L - 14' OR LESS 2- 0 4 FOR L - 15'TO25• COMPLETED DETAIL "C" DETAIL "C1" 0 �� NOTE: DETAIL"F' 3-#4 FOR L-26'TO 36' r CAN BE STRESSING END INSTALLATION BRICKLEDGE WHEN DETAIL11 SUBSTITUTED " DETAIL"F1" APPLICABLE FOR DETAIL"F1'. S' STRAND AS BRICKLEDGE WHEN , SHOWN ON PLAN -APPLICABLElool FIXED END PLASTIC yy 1- #4 BACK UP BAR ; ANCHOR SHEATHING \_CHAIR STRAND CUSHION ' CHAIR SAND. TIP. 77Y�/'''�-' _\` •-�(..r •• '.:'� ~� ,..•;i p \ 7+iy TOP OF`f ' POST -TENSION STRANDS i • !' SLAB STRANDS .h , , ! HAIR \ STRIP I .y / 13 SHEATHING GRADE�� 'a m •I/'•^j1�' ly WHERE APPLICABLE "�' \ � ^ _ SLAB STRANDS I WHEN INDICATED .��{'�,.I1(o I- j , ON PLAN, TYPICAL. +($ , - , / WHERE APPLICABLE ` \- \- STIRRUPS #4 BARS @ 12- WHEN I BS' STRAND AS i ;AIL STIRRUPS I. 2 x D TYPICAL L / SHOWN ON PLAN SPECIFIED WHEN SPECIFIED - I•,. • O.C.E.W. L WHEN (2)-BST STRANDS ARE / FIXED -END (DEAD-END) " DRAPE BEAM #3 STAKES AS REQUIRED — WOOD G n SPECIFIED IN THE BEAM, INSTALLATION N \ O —3- #4 BARS A j STRAND' CLEARANCE ARMAINTAINCEFROM ' FORM TOP VIEW +-3- #4 BARS {i • • WHEN INDICATED TIE'BS' STFL4NDS TOGETHER TOP & BOTTOM. TOP & BOTTOM. O + p Y( ON PLAN, TYPICAL CLEARANCE FROM THE AND INSTALL SIDE BY SIDE 4 OS / BOTTOM OF THE BEAM AS A SINGLE'BS' STRAND. E55 54' MAX. SPACING INSTALL ANCHORS SIDE BY SIDE I SEE'2DETAIL STANDARD DETAILS DETAIL "D" DETAIL "H" DETAIL "M" BEAM STRAND "BS" DETAIL q CID LO 6" 5 SPACES @ 3'-10" ± 5 SPACES @ 3'-11" ± co A co cn It CO 00 r- O O . m 0 O C d� d� "t (n m (n (n N (n (n (n m (n (n N (n (n u: r-- --I r -- --� r-- -- - -� r --- E II I II I I I I I I I I �i II I II I I cQ I I r I II II II b II II I I II II L___—____J II II II II II I II II I ---------- L-_____ r---------I II I - II r---------I r----- II II -� II r- ��-►} —� I II II II II I I 1 9'-11" III W-6" III 10'-0" I I 10'-5" 1 I I II I I I II III II L_____—__J L______ _- L______ __J L____—__1 r--------- - - - - - - -- r - - - - - - - - — q I II II I B II II II I I II I I I LO I I I I II I II II II � II II II II I I I II II L- — — — — — — — — -I L — — — — — — — I II — L — — — — — II II — — -i I r--------� I II r------- r------ II —� II r--------� I II I I I DROP II I I II I I I I I I I I o DROP 1 I II II II II � II II I I I I w I 13- #4 BARS I I I I I I I I oa I I I „ 6 "8 I I I L--- --- J U) L -- 1 L------ I I I --- - - �r -- ----- I1 A I ii I N I I ao I op I I I I I N I L----- II --J L------- J F------ ---1 II r---------� C I 11 I ' I co II II I I II J I L __I__ _J 10 —STEEL REQUIRED. SEE DETAILS 3W-10" u a LoM:oJla NOTES: 010 �1 V'�N t 2 1. TO PREVENT SETTLEMENT DUE TO SOIL CONSOLIDATION, aj ,••� Sr,• hl f DIAGONAL: ALL EXTERIOR FOUNDATION BEAMS MUST BE FOUNDED A ; • : �. � , 0, 70'-7 5/8" MINIMUM OF 12 INCHES INTO UNDISTURBED SOIL. WHEN ;• ; p ;Ln J� FOUNDATION SITE CONTAIINS FILL (MAX. 3'4), THE DEEPEN / u, : t Lu�� Q! �c BEAM DETAIL SHOULD BE USED IN THESE FILLED AREAS. i� O S �Q Z. S42 FOR SITES WHERE FILL IS GREATER THAN V-0", PLEASE a W•Z •�7 0� .�. w.� i CONTACT AGTM ENGINEERING LLC TO INCORPORATE PIERS �6 .. : Q:• BS43 INTO THE DESIGN. �s•'• 2. 3000 PSI, CONCRETE SLAB. S42 3. 4" OF CUSHION SAND UNDER CONCRETE SLAB IS11�ere:��~ RECOMMENDED. 4. PROVIDE A 6 MIL POLYETHYLENE MOISTURE RETARDER BENEATH SLAB AREA. Z S42 5. ALL STRANDS 1/2" DIA. - 270 K. O �- 6. THIS FOUNDATION DESIGN IS CONSIDERED INVALID (n 0) 2-BS43 UNLESS ACCOMPANIED BY A LETTER FROM AGTM W Z S ENGINEERING LLC AUTHORIZING ITS USE ON A SPECIFIC Q LOT & BLOCK, OR ADDRESS. 00 G � 7. PLANS CAN BE REVERSED ON LOT AT BUILDERS z = U? J j co 00 DISCRETION. 0 r U O S42 8. PLANS ARE FOR STRAND AND BEAM PLACEMENT ONLY. � ch A n °D �W U +t SET FORMS, DROPS, HANDICAP RAMPS, ETC., BY O r- °) ARCHITECTUAL FLOOR PLAN OR AS SPECIFIED BY LL ~ N p Op O O S42 c OWNER/GENERAL CONTRACTOR. z Z Q .. o 9. AT CONTRACTORS OPTION, LIVE END AND DEAD END z z . F- Z z w m BS43 w REVERSAL IS PERMITTED. O m U 10. AT CONTRACTORS OPTION, BRICK LEDGE MAY BE (n V tWi Z � O S42 U) INCLUDED OR OMITTED AT EXTERIOR DOOR OPENINGS, z U o � 1= J ~ W (n U) Q U motQ- S42 11. DRAINAGE, DRAINAGE, DRAINAGE. THE FINAL GRADE CIO IQ- M rn m AROUND THE FOUNDATION SHALL BE 8" BELOW THE TOP OFuj THE FOUNDATION AND SLOPE AWAY FROM THE O ~ W FOUNDATION A MINIMUM OF 3" IN 5'-0". U) U U OJ J S42 p o BS43 12. VIBRATE CONCRETE @ ALL CABLE LOCATIONS Q. CO ESPECIALLY AT CORNERS WHERE SEVERAL CABLES ARE O0 S42 ANCHORED. MAXIMUM CONCRETE DENSITY IS REQUIRED TO INSURE THAT A "BLOW-OUT," DOES NOT OCCUR DURING riI CABLE STRESSING. UJI = T Ow 00 13. THE FOLLOWING SYMBOL INDICATES DROP IN T S42 FOUNDATION. THE AMOUNT OF DROP AND EXACT c I- LOCATION IS TO BE DETERMINED BY PLAN OR AS N S42 DIRECTED BY OWNER/CONTRACTOR. 2-BS43 a S23 c t1 FOUNDATION: w 0 1. THICKNESS T= 4' O S23 2. BEAM WIDTH W= 10" g U BS24 co 3. BEAM DEPTH D= 33" o m S23 v 4. AREA = 1978 SQ. FT. mw 9 O dR 5. EST. CONCRETE = 75 YRDS. > b m S23 "' 6. SOILS REPORT: Z LL 0 CME TESTING AND ENGINEERING, INC. a Q S23 1806 WELSH AVENUE, SUITE C o o 1 Cc COLLEGE STATIONI, TEXAS 77840 U BS24 PROJECT NO.26116 --I W DATED: OCTOBER 2, 2006 c ZcoLbE § m OD G N N Ua CAUTION: I N THE E EVENT THAT A CABLE ui jg PASSES THROUGH A PLUMBING OPENING,=ENDEN RATE ALL CABLE UVEMOVE CABLE TO EDGE OFOPENING. TO ENSURE MAX. LU UCABLE SPACING CAN BE ADJUSTED, BUT INETE, ESPECIALLY fNO EVENT CAN CABLE SPACING BE ULTIPLESTRANDSw GREATER THAN 60D.C. R FRONT VIEW 3" GRID PATTERN 8d '16" MIS COMMON NAILS TO HEADER .. . TOP PLATE TO HEADER - 2 ROWS OF a 16d SINKERS, 3"O.C. 3" O.C. NAILING IN ALL FRAMING -STUDS, BLOCKS, TOP PLATE, AND BEHIND THE STHD10 HOLDDOWN 3 BOTTOM PLATE _ TYPICAL 5/8" ANCHOR BOLT EMBEDDED 7" MIN. TYPICAL. SIMPSON LSTA21 OR CS20 (ATTACH TO FRAMING ON OPPOSITE SIDES OF SHEATHING) TYPICAL BOTH SIDES OF OPENING. ' a. 0 T SIMPSON LSTA21 OR CS20 (ATTACH TO FRAMING ON OPPOSITE SIDES OF SHEATHING) TYPICAL BOTH SIDES OF OPENING. -2- SIMPSON HTT16 EACH SIDE - TYPICAL HEADER CLEAR, SPAN ACROSS ALTERNATE 1-STORY - 1611 MIN. —TfPiCAi BO"I'4SIDES`-- FRONT VIEW r-HEADER CLEAR SPAN ACROSS 3" GRID PATTERN 8d 11 COMMON NAILS TO HEADER •17. TOP PLATE TO HEADER - 2 ROWS OF 16d SINKERS, 3"O.C. 3" O.C. NAILING IN ALL FRAMING -STUDS, BLOCKS, TOP PLATE, AND BEHIND THE STHD10 HOLDDOWN -2- SIMPSON STHD14 5/8" ANCHOR BOLT EACH SIDE - TYPICAL 3 BOTTOM PLATE EMBEDDED 7" MIN. TYPICAL TYPICAL �TQ11�6" M I N __ FRONT LESS THAN LESS THAN 12'-T o Z/l � LESS THAN 2'-6° 12'-6' LESS THAN 25-0° LESS THAN 25-01 TYP. 39'-10° LEFT BLOLOZOdMB h 0 • :IA Q: CJ a 3 a ��••. i 's .•• w *: o o 0 U) J W z ►= W m co Fn 0 cr� D I-- CV U o�C O �co Tp00 QZNoz W� I—Z pmoI Z�J[il QC):cZW V �,� Z^�z Do g W o V �� Qv J CLm0 Q Q Mew RIGHT Z COV o w J O �p U O 3 ru = T O � O a Z4 0 8 N d a- d m r f0 0 Q W U O� w O m O a¢ m?. ° � ® 0 Q �Q w o U) 2 O U (A Q G w 0 J E LLi 8 c _ CD I 3 ( Z CO °D C n N W f W C w c�tl w Q Q w BUILDING PERMIT CITY OF COLL'iTATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 07-00000561 Date 3/20/07 Property Address . . . . . . 907 TURTLE DOVE TRL Property ID: 005401-0207-0350 R #• Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . DOVE CROSSING PH 2 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 104412 Owner Contractor ------------------------ ------------------------ CLASSIC CENTURY HOMES 5001 HWY 287 S BURLESON TX 76028 (817) 561-4369 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1582.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC TAZ 405.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . GS Permit Fee . . . . 475'.00 Plan Check Fee .00 Issue Date . . . . 3/20/07 Valuation . . . . 104412 Expiration Date . . 9/16/07 Qty Unit Charge Per Extension BASE FEE 460.00 5.00 3.0000 THOU BLDG, VAL 100001-500000 15.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 2211 --------------------------------------------- ---- -- BUILDING DEPT REPRES NTATIVE: - ---------- APPLICANT: BUILDING PERMIT CITY OF COLL-EGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 2 Application Number . . . . . 07-00000561 Date 3/20/07 ---------------------------------------------------------------------------- Special Notes and Comments X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8" side & 16" front) For Openings >6 sq. ft. (12" side & 20" front) ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIA KNOWLEDGE/EFFORT THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEA RED AI�J- HG+�` BUILDING DEPT REPRESENT APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 3 Application Number . . . . . 07-00000561 Date 3/20/07 ---------------------------------------------------------------------------- Special Notes and Comments PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12' ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe to U.V. light. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDI TE VICINITY OF THE ------------------------------------------------�-- • -- ---------- BUILDING DEPT REPRESENTATIVE) �1 APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 4 Application Number . . . . . 07-00000561 Date 3/20/07 ---------------------------------------------------------------------------- Special Notes and Comments BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND CLOTHES DRYERS. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ------------------------------ --------------------------- Permit Fee Total 475.00 475.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1225.00 1225.00 .00 .00 -------------------------------------------------�--- --- --"------------ BUILDING DEPT R,EPRESENTATI E: APPLICANT: TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 07-00000563 Date 3/20/07 Property Address . . . . . . 907 TURTLE DOVE TRL Property ID: 005401-0207-0350 R #. Application type description TEMP POLE Subdivision Name . . . . . . DOVE CROSSING PH 2 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 0 Owner Contractor ------------------------ ------------------------ CLASSIC CENTURY HOMES 5001 HWY 287 S BURLESON TX 76028 (817) 561-4369 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . GS. Permit Fee . . . . 20.00 Issue Date . . . . 3/20/07 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited ------------------------------ Due ----------------- Permit Fee Total ---------- 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 ------------------- BUILDING DE APPLICANT: