Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ADDN2007-00556
PREPARED 4/23/07, 8:00:58 INSPECTION TICKET PAGE 5 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 4/23/07 ------------------------------------------------------------------------------------------------ ADDRESS . : 1529 FONTAINE DR SUBDIV: FOXFIRE #2 TENANT, NBR: MODIFYING GARAGE CONTRACTOR HOMEOWNER PHONE OWNER KUSLER, KELLY WADE PHONE PARCEL 277500-0209-0110 APPL NUMBER: 07-00000556 RESIDENTIAL, ADDITION ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B115 01 3/21/07 JGM BLDG, FRAMING TIME: 17:00 3/21/07 AP March 20, 2007 3:09:31 PM glsouth. March 21, 2007 9:32:52 AM kwolfe. B125 01 C /�a�L47 B_I_ BLDG, FINAL TIME: 17:00 (((�V/ „a'�L April 20, 2007 11:05:25 AM kwolfe. -- CONTINUED ONTO NEXT PAGE--------- f. i S �� Date: 4/23/2007 Inspection Comments for Finals Permit Year: 7 Permit Number: 556 Address: 1529 FONTAINE DR Type Inspection Type Code Stags Inspection Result Comments Description B115 BLDG, FRAMING IC March 21, 2007 9:32:52 AM kwolfe. Ell ELEC, ROUGH IN IC March 21, 2007 9:29:07 AM kwolfe. P105 PLBG, TOP OUT IC March 21, 2007 9:33:02 AM kwolfe. Page 1 City of College Station 1101 TEXAS AVENUE COLLEGE STATION TX 77840 C E R T I F I C A T E O F C O M P L E T I O N P E R M A N E N T Issue Date . . . . . . 4/23/07 Parcel Number . . . . . 277500-0209-0110 Property Address . . . 1529 FONTAINE DR COLLEGE STATION TX 77845 Subdivision Name . . . FOXFIRE #2 Legal Description . . . FOXFIRE #2, BLOCK 9, LOT 11, A CRES 1.16 Property Zoning . . . . AGRICULTURAL OPEN Owner . . . . . . . . . KUSLER, KELLY WADE Contractor . . . . . . HOMEOWNER Application number 07-00000556 000 000 Description of Work RESIDENTIAL, ADDITION Construction type . . . COMBUSTIBLE (UNPROTECTED) Occupancy type . . . . RESIDENTIAL-SFR/DUPLEX Flood Zone . . . . . . j A /'-9 - A4-. Approved . . . . . . . cia VOID UNLESS SIGNED BY BUILDING OFFICIAL BUILDING PERMIT •w«►.:a CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 ----------------------------------------------------------- FAX: (979)764-3496 ----- ------------- Application Number . . . . . 07-00000556 Date 3/01/07 Property Address . . . . . . 1529 FONTAINE DR Property ID: 277500-0209-0110 R #: R27621 Tenant nbr, name . . . . . . MODIFYING GARAGE Application type description RESIDENTIAL, ADDITION Subdivision Name . . . . . . FOXFIRE #2 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . RURAL RESIDENTIAL SUB. Application valuation . . . . 15000 Owner Contractor ------------------------ ------------------------ KUSLER, KELLY WADE HOMEOWNER 1529 FONTAINE DR 1101 TEXAS AVE COLLEGE STATION TX 778455609 COLLEGE STATION TX 77840 --- Structure Information 000 000 MOTHER IN LAW QUARTERS Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE MASONITE IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB TYPE OF GARAGE (ATT/DET) NA HEATED AREA 473.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 1.00 NUMBER OF BEDROOMS 1.00 SEWER TYPE PUBLIC TAZ 1.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . NC Permit Fee . . . . 85.00 Plan Check Fee .00 Issue Date . . . . 3/01/07 Valuation . . . . 15000 Expiration Date . . 8/28/07 Qty Unit Charge Per Extension BASE FEE 15.00 14.00 5.0000 THOU BLDG, VAL 1001-50000 70.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS OPENING (MINIMUM ROU H-FRAMED SIZE 22" -------------------------------------------- - - ---�-- --- ---------- BUILDING DEPT_REPRESEN A,IVE: APPLICANT : BUILDING PERMIT • CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 07-00000556 Page 2 Date 3/01/07 Special Notes and Comments X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE ADD SMOKE DETECTOR(S) PER NOTES ON PLANS SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING BUILDING DEPT REPRESENTP,b,TTVE : _� APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION r 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 3 Application Number . . . . . 07-00000556 Date 3/01/07 ---------------------------------------------------------------------------- Special Notes and Comments EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK Add Smoke detectors inside and outside bedroom. Window unit to also provide heat. Detached garage being converted to Mother -in -Laws Quarters. Primary House is 1886 sq. ft. and accessary structure is 473 which is 25% of primary. ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total 85.00 85.00 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 85.00 85.00 .00 .00 BUILDING DE APPLICANT: APPLICATION FOR BUILDING PERMIT 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX CITY OF COLLEGE STATION. VdVUW I-QTY r:nv Planning 6-�Pe 4ejrnentSer!'co ADDRESS/LOCATION: For Ofgce Use Only - DATE: TRCCREEG��/�, APPLICATION # TEMP POLE # LOT BLOCK SUBDIVISION /� SEC/PH / BUSINESS/OWNER NAME:t�Jty- I� PHONE: e;5�9 CONTRACTO OMEOWNER: PHONE: CONTRACTOR ADDRESS: ELECTRICIAN: D PLUMBER: HVAC: GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ONLY DUPLEX (Landscape Plans) REMODEL/RENOVATION* SWIMMING POOL TENT/CANOPY DESCRIPTION OF WORK: [/ Rook (-4-4L PROPOSED USk-9fLtrl YkmAN,,_it. Lc it ag, ! Qa. HOMEOWNER ASSOC IATI ON/ARCH ITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ I Si 0 O O - Dy TOTAL AREA: JC�oZ HEATED AREA: t4-13_ (Cost of Labor and Materials) PUBLIC SEWER NUMBER OF BEDROOMS: / SEPTIC%TREATMENT SYSTEM NUMBER OF BATHROOMS: SEWER TAP: INTERIOR WALL TYPE: 9 ��'�rwU SIZE � WATER TAP: EXTERIOR WALL TYPE: Mgt' S oy 4 -C SIZE OTHER TAP: FOUNDATION TYPE: f 4, • SIZE ❑ TEMP POLE ROOF TYPE: tyk,-�A-� 1 GARAGE TYPE: SINGLE F7 DOUBLE a TRIPLE ATTACHED n DETACHW F,] CARPORT SIGNATURE OF APPLICANT: vVd` *If proposed work involves new com ercial onstruction or facade improvements/renovations to an existing commercial property, building elevations are required. Official Use Only .�:a Plans Examiner Zoning Official O�I�IA; N �u se ���` i� I Act", gN ents: ES r q73 A5% vi�,,,r� � k ut 44- l- ' Fire Marshall tcto p Energy Code Compliance Information 0 % Glazing of exterior walls Insulation R value of exterior walls R 3 Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) N ;k Glazing SHGC I I • qO Glazing U-Factor .75 R value of ductwork A - A/C SEER Rating U-ke',4 Q,A) Is N O BETH GASTON 1529 FONTAINE COLLEGE STATION, TX 77845. (936) 349-5903 22' GARAGE DOOR 4I5' RAW SPACE 4I 7.5' 2.5' 12' TUB � 53 7.5' OW T BATH ROOM BEDROOM WO on 9.5' Sa M REF P 2 e8' 12'1 10 00 LIVING 12' 7.5' 6n DINING .. 27' NOT TO SCALE SITE PLAN FLOOR PLAN 473 Sq.Ft. Legend Window NJ Sink —Z'J Toilet --- Pantry —© Water — 1f Heater Elea+'c� A"a f N MMCARTFRIR SURVEYS INC. \ \ \ P.O. 80X 4502 \8R{g 91 E7A5•afi0gs \,\ � \Q .... .... -. \ \ LOT 12 . .. NORTH \�.5 20'25' S'W R 10 GRAPHIC yGA1.E Ofw it' S 47'4B'17'E R -- Mir O 20 40 .. __. 271.)O'R 271.00'M IN FEET "J` f . t0' UTILITY EASB.fNT ; .. ................... ... s }r ... Ift14 E�'BPJ1f— 'r .. .. cD .. R RECORD LOT 10 '•.-\,\ WMAIREV la\RKER9 ARE Gi• : fG1.E 44 ot'IRON. R0D9 /ER MAT ' yr IRON W j : �' •rano' GARAGE n '` GK DURIED FAGILITIe�/li Y. •i 1l' liDL�0 ` I �. 4. ADA'e yG01M fAG IL IT IEi rµ.Y ARE I- y ..• 1\\1, LDLATED ON TM19 %VMMV" A9 '/OIH. I• _ Y: I O' Y rD iNYe peC1ED rat lLlrlEe LOLaTED C. - TWO STORY ^ 1 . I61 .i6LRE5 a T,C FROIND No BEFORE AP!!'p¢avar lLTr , Ii; 1i0U�iE _ ` erAxr 7YE ORtiR Q n4 ILDAa Zq �I u.eTrl ,1�� m c Q c ne roraa art call. sn �-qI I our CA OT,rALr® 1-0OO�r.S-.9a5 \.'„O�.I..:-. ••.•••••lf:o•.I"'... ®. .... laaa.ona�al l.cae \ \ •:-.:cpyD JGRnI w .. i \(AA,I.T �1+ ' •J R1� c s 0" T&X 1 y Ili• � FIREa�y`_ µy./N\--. •... GRD.. RCy7^Zr_ _ _ 'I Deed Restrictions >REW ''D.R. 359/123 T� i`a[iiai'paJ•.' O.R. 5330/208,6068/127 �_ var — . reLe -_33 33.g0• 'Box U.D. Ordinance c+ti:2� 16' UrfLITY EASEIENr y'� 'i,. �••T September 23, 2004 bhp. Z3q ' 66 R . a ®vA YE 152c, Rgp'g91,g2 .� �:� :::� Dig _.—_---- REriae fro.vz' 79.68'R 79.79'M kD v:' University Title Company F /\�7- I D L4£RT N 45' 00' 14'W R O1 V 1 ,(� 11vF GFNo- 00070385 co R.o.�' rERrLar DR! VC Lot Eleven (11), Block Nine (9) FOXFIRE PHASE 2, City of College Station, according to the plat thereof recorded in Volume 358; Page 291 of the Deed Records of Brazos County, Texas. L James W. MacArthur,'Registered Professional Land Surveyor, No. 2089, do hereby certify that this plat correctly represents a Survey made by me or under my direction, on the ground, February 10, 2007. This plat was prepared for the purpose of Title Survey for Gaston. #07-5628 There are no visible or apparent intrusions other than those shown hereon. W na.r t — the. information scaled from the FEMA mandated February, 9,1000,_Panel No;-_-----