HomeMy WebLinkAboutRES2007-00539, 07-540r bfia;
PREPARED 6/28/07, 7:25:30 INSPECTION TICKET PAGE 7
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 6/27/07
------------------------------------------------------------------------------------------------
ADDRESS . : 1020 FALLBROOK LOOP SUBDIV: WESTFIELD VILLAGE PH 5
CONTRACTOR STYLECRAFT BUILDERS PHONE (979) 690-1222
OWNER . . PHONE
PARCEL . . 005401-0512-0010
APPL NUMBER: 07-00000539 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 3/21/07 OC BLDG, FOUNDATION -SLAB TIME: 17:00
I 3/21/07 AP March 20, 2007 3:30:10 PM kwolfe.
Strings On Setbacks O.K.
Slab Ground Installed
B115 01 4/24/07 RH BLDG, FRAMING TIME: 17:00
4/24/07 AE April 24, 2007 9:12:31 AM glsouth.
04/24/2007 02:30 PM RH PDA
Add draftstop at arches and joist hangers in livingroom at
hallway.
B130 01 4/26/07 OC BLDG, INSULATION TIME: 17:00
4/26/07 AP April 25, 2007 3:16:02 PM glsouth.
B132 01 5/03/07 JGM BLDG, SHEETROCK FASTENER TIME: 17:00
5/03/07 AP May 2, 2007 3:13:30 PM glsouth.
B125 01 A27/`077 � BLDG, FINAL TIME: 17:00
CC June 27, 2007 2:32:05 PM glsouth.
---- COMMENTS AND NOTES --------------------------------- --------------------------------------
J
�IJa Do��;9�
Date: 6/28/2007
Inspection Comments for Finals
Permit Year: 7 Permit Number: 539
Address: 1020 FALLBROOK LOOP
Insp.
Inspection Type Code
p.
status
Inspection Result Comments
Description
B100
BLDG, FOUNDATION -SLAB
IC
Strings On Setbacks O.K.
B100
BLDG, FOUNDATION -SLAB
IC
Slab Ground Installed
B115
BLDG, FRAMING
IC
04/24/2007 02:30 PM RH PDA
B115
BLDG, FRAMING
IC
Add draftstop at arches and joist hangers in livingroom at
B115
BLDG, FRAMING
IC
hallway.
P125
PLBG, FINAL
IC
Pressure Test Not Holding
Page 1
WF0880605 / 001 City of College Station b CIO
' �`
PAGE 1
REQ. DATE: 03/13/07 03/13/07 15:18:23
LOCATION: 1020 FALLBROOK LOOP LOC ID: 203906
REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN
REQ USER: NCOCHRAN AUTH USER:NCOCHRAN WRK TYPE:
TEMP POLE PASSED
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 03/13/07 SCHED COMPLETION: 03/13/07
********************************************************************************
JOB ORDER RESULT COMIENTS
WFO880648 / 001 City of College Station PAGE 1
REQ. DATE: 03/13/07 V 03/13/07 16:44:26
LOCATION: 1020 FALLBROOK LOOP LOC ID: 203906
REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN
REQ USER: KWOLFE AUTH USER:KWOLFE WRK TYPE:
TEMP POLE PASSED
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 03/13/07 SCHED COMPLETION: 03/13/07
********************************************************************************
JOB ORDER RESULT COMMENTS
WF0878586 / 001 City of Colle�Station
Ile
PAGE 1
REQ. DATE: 03/05/07 03/05/07 13:50:25
LOCATION: 1020 FALLBROOK LOOP LOC ID: 203906
REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN
REQ USER: NCOCHRAN AUTH USER:NCOCHRAN WRK TYPE:
3/4" WTR TAP 4" SWR TAP
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 03/05/07 SCHED COMPLETION: 03/05/07
********************************************************************************
JOB ORDER RESULT COMMENTS
SHEET:
G-1
AREA
SUMMARY
co
co
En
EnNun
oO�O�NooN
"
U
Q
�Wa
UQ
¢
a�aa
=j.
�
vn
oo¢<owo
.
HUc7HaH
0
N
��
°oAgw�
Qz
ai 00
1020 FALLBROOK LOOP
w
WESTFIELD VILLAGE
wo
LOT - 1
0 w 0
BLOCK - 12
PHASE - 5
a
Q
w
��� N
Q N N
Q
�gz
WUa�O
110
QU¢ U
1 FRONT ELEVATION B
.................
SCALE: 3/16"=1'-0"
SHEET INDEX
COVER SHEET
G-1
SITE PLAN
C-1
FLATWORK DETAILS
C-2
FOUNDATION PLAN
S-1
DIMENSION PLAN
S-2
FRAMING PLAN
S-3
ROOF FRAMING PLAN
S-4
DECKING LAYOUT
S-5
FRAMING DETAILS
S-6
FLOOR PLAN
A-1
DETAILS
A-2
ELEVATIONS
A-3
CABINET LAYOUT
A-4
FLOORING PLAN
A-5
ELECTRICAL PLAN
E-1
VERSION
#
DATE
REVISION
0
8/15
MASTER APPROVED
1
11/13/O6
SECOND MASTER SINK OPTION ADDED
2
11/13lO6
CABINETS CHANGED: MASTER BATH, KITCHEN
SHEET:
FINISHING NOTES C-1
1. BLACK MICROHOOD AREA
2. LOT INCLUDES STREET SIDE FENCE & SOD TO REAR SUMMARY
wwww= w
PROPERTY LINE
o0"1O�NooN
3. ACCENT COLOR IN M. BATH, NOT KITCHEN
4. — a —EAR e1E_�, x
5. a
U
00 owwo
I I
CLEA LEVEL & 1
' READ FOR FORMS'
00
I I 0
VI I O
1 QI I
ml
I I
wlcf)1 I >cn
7 Lo
� a
v
� `jX O
'
z
-,A
Z 1 F NCE oo
1 �O
I IY M W 0
i i L PROPOSED m Gq
F NCE 1 RESIDENCE !WNN
UATL Rn -L) �r a
w
04 ~ O �' x
1 N U
I� Z � �
I
I ^
" I 29'-91" 71-01"
' TWO CA ' w
GARAGE
I ; I
L 2 ---- --- T SE BA
� I
1020 FALLBROOK LOOP W) rn \N § WESTFIELD VILLAGE Q N N N
LOT - 1 Q
BLOCK - 12 z Q Q
NC. TR 55 � PHASE - 5 - Q z V U
WASHOUT 1 ONC. o ¢ wok Q z
HERE BRICK � R:�] w
❑ MAILBOX Q U �+ O
1020 a w w M
1 SITE PLAN
SCALE: 1 "=20'-0"
BUILDING PERMIT
"`'"`�•� CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number 07-00000539 Date 3/05/07
Property Address . . . . . . 1020 FALLBROOK LOOP
Property ID: 005401-0512-0010
R #•
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . WESTFIELD VILLAGE PH 5
Property Use . . . . . . RESIDENTIAL
Property Zoning . . . . . . . PLANNED DEVL HOUSING
Application valuation 78210
Owner
Contractor
------------------------
------------------------
STYLECRAFT BUILDERS
4090 SH 6 S
COLLEGE STATION
TX 77845
(979) 690-1222
--- Structure Information
000 000 SINGLE FAMILY
Construction Type
COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info
EXTERIOR WALL TYPE
MASONRY
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
1185.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
2.00
NUMBER OF BEDROOMS
3.00
SEWER TYPE
PUBLIC
TAZ
405.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
NC
Permit Fee . . . .
376.00 Plan Check Fee
.00
Issue Date . . . .
3/05/07 Valuation . . .
. 78210
Expiration Date . .
9/01/07
Qty Unit Charge
Per
Extension
BASE FEE
260.00
29.00 4.0000
THOU BLDG, VAL 50001-100000
116.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS
THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL
BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS
OPENING (MINIMUM ROgGH-FRAMED SIZE
22"
----------------------------------------------
BUILDING DEPT RR15RES NTATIVE: _ RV
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 07-00000539
Page 2
Date 3/05/07
Special Notes and Comments
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEAjURED AT THE
BUILDING DEPT REPAES
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 FAX: (979) 764-3496
Application Number . . . . . 07-00000539
Page 3
Date 3/05/07
Special Notes and Comments
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHI 24" OF DOORS IN
--------------------------- ---------------- ---- /V•-- ---- - ---------
BUILDING DEPT REP SEN ,�.� ��
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 FAX.: (979) 764-3496
Page
4
Application Number 07-00000539 Date
3/05/07
----------------------------------------------------------------------------
Special Notes and Comments
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND
CLOTHES DRYERS.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------------------------------
-----------------
Permit Fee Total 376.00 376.00 .00
.00
Plan Check Total .00 .00 .00
.00
Other Fee Total 750.00 750.00 .00
.00
Grand Total 1126.00 1126.00 .00
.00
BUILDING DE
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 07-00000540 Date 3/05/07
Property Address . . . . . . 1020 FALLBROOK LOOP
Property ID: 005401-0512-0010
R #.
Application type description TEMP POLE
Subdivision Name . . . . . . WESTFIELD VILLAGE PH 5
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . PLANNED DEVL HOUSING
Application valuation . . . . 0
Owner
Contractor
------------------------
------------------------
STYLECRAFT BUILDERS
4090 SH 6 S
COLLEGE STATION
TX 77845
(979) 690-1222
--------------------------------------------------------------
Permit . . . . .
. TEMP POLE
7-------------
PERMIT
Additional desc .
. NC
Permit Fee . . .
. 20.00
Issue Date . . .
. 3/05/07
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary
Charged
----------
Paid Credited
------------------------------
Due
-----------------
Permit Fee Total
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
------------ -------- C
BUILDING DEPT REPRE--NTA IVe7-----
APPLICANT: ' V / /
For OFew Use Only
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
(*Op�
COLLEGE STATION, TX 77840
CITY OF COLIEGE STA-RON (979) 764-3570 (979) 764-3496 FAX
PbnniagWWW.CSTX.GOV
DATE. `�T%RCC REG
APPLICATION #
TEMP POLE # 1C /� ✓"I�
ADDRESS/LOCATION: _ 10 Lo t=q« f �RO0 K, ! r V
LOT �� BLOCK 12 SUBDIVISION _WEST FIEj_n VI LLAUG °� SEC/PH
BUSINESS/OWNER NAME: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120
CONTRACTORIHOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120
CONTRACTOR ADDRESS: 4090 State Highwav 6 South
ELECTRICIAN: Brazos Valley Electric PLUMBER: Bass Plumbing
HVAC: Control Temp GOOD CENTS (Residential only): No
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) H
NEW CONSTRUCTION * SLAB ONLY
DUPLEX (Landscape Plans REMODEURENOVATION* SWIMMING POOL
Required)
DESCRIPTION OF WORK: Conventional Framing
STRUCTURE USE: Single Family Residence
HOMEOWNER ASSOCIATIOWARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ N/A
VALUATION: $ _78 Ito ✓ TOTAL AREA: I &Z-1 HEATED AREA: I
/� (Cost of Labor and Materials)
JL3❑
PUBLIC SEWER
SEPTIC/TREATMENT SYSTEM
/O OX SEWER TAP: 4"
SIZE
rr ® WATER TAP: Yon
SIZE
OTHER TAP:
i
X TEMP POLE
`f\ / GARAGE TYPE:
NUMBER OF BEDROOMS: 3
NUMBER OF BATHROOMS: 2-
INTERIOR WALL TYPE: Sheet Rock
EXTERIOR WALL TYPE: Siding and/or Masonry
FOUNDATION TYPE: Slab on Grade
SIZE
ROOF TYPE: Composition
SINGLE DOUBLE TRIPLE a
ATTACHED a_,_QETACHED CARPORT FI
SIGNATURE OF APPLICANT: For Stylecraft
*If proposed work involves new commercial construct n or f ade improvements/renovations to an existing
commercial property, building elevations are required.
e0000eoe000eeooee0000.0o00000000000e0e0000o000000000000000000
Official Use Only
� X 3 _ I Comments.
�r NO
Plans Examiner Zoning Official
--GaLrtoge vII'Ip ✓� �oi3 �i�G���rl
I
Energy Code Compliance In rmation
% Glazing of exterior walls
0
Insulation R value of exterior walls
R13 J
Insulation R value of ceiling 1 (flat areas).
R30 ✓
Insulation R value of ceiling 2 (vaulted areas/no attic)
R19
Glazing SHGC
.40
Glazing U-Factor
.65 ►�
R value of ductwork
R6
A,/C SEER. Rating
13:=
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER#
DATE:
BUILDING ADDRESS:
o a o k �-
I. Foundation Requirements
N
A.
Concrete minimum fc of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F.
Wood foundation details indicated
OK
II. Framing:
Floor, Wall, Ceiling and Roof Requirements
NA/
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
OK
1. One -hour rated extending to roof deckAYOK
E.
Header sizes indicated on plans
N
F.
Emergency bedroom egress
1. Exit direct to outside
2. O enable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
O enable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
III. Stairway Requirements
K
A. Stairway Details
K
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than twenty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements to be indicated onplans)
K
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
NIT
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
N
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N K
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units)
T
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
N
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
A/
Maximum drive width for residence is 28' combined for circular
Minimum 30 feet from driveway to side(intersecting) street
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
N
Does not block any water course or divert any flow
Elevation certificate needed
foul
"APPROVED PLANS PER IRC SECTION R106.3.1."
L EXAMINER
3-l-19--7
DATE
1
REScheck Software Version 3.7.3
Compliance Certificate
Project Title: Plan # 1185-WVCO
Report Date: 02/28/07
Data filename: S:WCAD\Archived\Old REScheck\1020 FALLBROOK.rck
Energy Code:
2000 IECC
Location:
College Station, Texas
Construction Type:
Single Family
Glazing Area Percentage:
11 %
Heating Degree Days:
1788
Construction Site:
Owner/Agent:
Permit Date: 2-28-2007
Maximum SHGC: 0.40 Your SHGC: 0.40
Ceiling 1: Flat Ceiling or Scissor Truss:
Ceiling 2: Cathedral Ceiling (no attic):
Wall 1: Wood Frame, 16" o.c.:
Window 1: Metal Frame, Double Pane with Low-E:
SHGC: 0.40
Door 1: Solid:
Door 2: Glass:
SHGC: 0.40
Floor 1: Slab -On -Grade: Unheated: , Insulation Depth: 0.0'
Air Conditioner 2: Electric Central Air: 13 SEER
Furnace 2: Forced Hot Air: 80 AFUE
Permit #
Permit Date
r " .''.
Designer/Contractor:
999 30.0
0.0
35
186 19.0
0.0
10
1192 13.0
0.0
84
112
0.670
75
38
0.500
19
18
0.440
8
149
0.0
155
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in
RESchec rsion 3.7.3 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
5rgLEClZAFT- 3viLDER5 z12&L07
Builder/Designer Company Name Date
Project Notes:
Previously saved project information:
MEDLIN
1020 Fallbrook Loop
College Station, Texas
Stylecraft Builders, Inc.
4090 St. Hwy. 6 S.
College Station, Texas 77845
Plan # 1185-WVCO
Page 1 of 1