HomeMy WebLinkAboutRES2007-00537, 07-538PREPARED 8/06/07, 11:59:03 INSPECTION TICKET PAGE 8
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 8/06/07
------------------------------------------------------------------------------------------------
ADDRESS . : 1010 FALLBROOK LOOP SUBDIV:
CONTRACTOR STYLECRAFT BUILDERS PHONE (979) 690-1222
OWNER . . PHONE
PARCEL . . 650730-0512-0060
APPL NUMBER: 07-00000537 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 4/04/07 OC BLDG, FOUNDATION -SLAB TIME: 17:00
4/04/07 AP April 3, 2007 1:59:06 PM glsouth.
Strings On Setbacks O.K.
Slab Ground Installed
B115 01 6/11/07 OC BLDG, FRAMING TIME: 17:00
6/11/07 AP June 11, 2007 8:17:56 AM acarter.
B130 01 6/13/07 OC BLDG, INSULATION TIME: 17:00
6/13/07 AP June 13, 2007 11:23:14 AM kwolfe.
B132 01 6/18/07 RH BLDG, SHEETROCK FASTENER TIME: 17:00
6/18/07• AP June 15, 2007 9:58:20 AM glsouth.
MONDAY MORNING
B125 01 �/07 BI ///��� BLDG, FINAL TIME: 17:00
fC� August 6, 2007 8:22:59 AM acarter.
---------------------`-----"------------- COMMENTS AND NOTES --------------------------------------
Y V 6 ��
Date: 8/6/2007
Inspection Comments for Finals
Permit Year: 7 Permit Number: 537
Address: 1010 FALLBROOK LOOP
Insp.
inspection Type code
p.
status
Inspection Result Comments
Description
B100
BLDG, FOUNDATION -SLAB
IC
Strings On Setbacks O.K.
B100
BLDG, FOUNDATION -SLAB
IC
Slab Ground Installed
P125
PLBG, FINAL
IC
July 17, 2007 4:02:15 PM kwolfe.
Page 1
WFO884875 / 001 City of College Station PAGE 1
REQ. DATE: 03/29/07 �, 03/29/07 11:21:22
LOCATION: 1010 FALLBROOK LOOP LOC ID: 203896
REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN
REQ USER: KWOLFE AUTH USER:KWOLFE WRK TYPE:
TEMP POLE PASSED
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 03/29/07 SCHED COMPLETION: 03/29/07
********************************************************************************
JOB ORDER RESULT COMU24TS
WF0878587 / 001 City of College,Station PAGE 1
REQ. DATE: 03/05/07 03/05/07 13:51:11
LOCATION: 1010 FALLBROOK LOOP LOC ID: 203896
REQUESTOR: STYLECRAFT ORIGIN: CUSTOMER -WALK IN
REQ USER: NCOCHRAN AUTH USER:NCOCHRAN WRK TYPE:
3/4" WTR TAP 4" SWR TAP
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 03/05/07 SCHED COMPLETION: 03/05/07
********************************************************************************
JOB ORDER RESULT COMMENTS
SHEET:
G-I
AREA
SUMMARY
wwww= w
�cncncn��
kn v�tn60kn
in �o to r- , �
�--� M •--� .--� •--�
N N
U Ll
Ua �¢
QQW EW"�i
oo E-
M
00
O N
O
O n
p Q
a
1010 FALLBROOK LOOP w a
WESTFIELD VILLAGE o Z
LOT-6 O
BLOCK - 12 a
PHASE-5 a
F
y
w
U
<Q
Q N
a=i -
--__ oQz�Q
00 �Q°u,Q�z
oaooaaoo ��� �w
QUa�OU
oa000000 >�
_ o000000a oo - - - W
I FRONT ELEVATION A
SCALE: 3/16'=1'-0'
SHEET INDEX
COVER SHEET
G-1
SITE PLAN
C-1
FLATWORK DETAILS
C-2
FOUNDATION PLAN
S-1
DIMENSION PLAN
S-2
FRAMING PLAN
S-3
ROOF FRAMING PLAN
S-4
DECKING LAYOUT
S-5
FRAMING DETAILS
S-6
FLOOR PLAN
A-1
DETAILS
A-2
ELEVATIONS
A-3
CABINET LAYOUT
A-4
FLOORING PLAN
A-5
ELECTRICAL PLAN
E-1
VERSION
#
DATE
REVISION
0
9/1 1
MASTER APPROVED
1
9/25
DELETED SIDELITE, MOVED FRONT PORCH INTO EVEN WALL
2
1?J1/O6
DELETED RB IN GARAGE, ADDED CJ
3
1/11/07
CHANGED zx6 CEILING JOISTS TO tf3 YELLOW PINE
FINISHING NOTES
1. LOT INCLUDES RIGHT HAND & REAR YARD FENCE
2. VENT MICROVENT TO EXTERIOR
3. SEPARATE OVEN AND COOKTOP (OVEN - JTP02BFBB
COOKTOP - JP340BJBB)
4. BLACK MICROHOOD
5-c
PROPOSED
iiV
N&S
RESIDENCES
o
Ilm ui
Il
,
'16 -11 n
37'-91•
w
I I� 10.-83.
o
I—
i I TWO
4C/Aj--��/
GAR
I
I
I
,
I
�I
I
I
I
1
MAILBOX
)IV ETB - a
CN
3920'
NC. TRUCK
C WASHOUTFK
HER
1 SITE PLAN
SCALE: 1'=20'-0'
1010 FALLBROOK LOOP
WESTFIELD VILLAGE
LOT-6
BLOCK - 12
PHASE - 5
SHEEP:
C-1
AREA
UMMARY
►- k-
O
N
N
L)�
n_
m
O
O
W
O
z
w
�
W
a
a
O
O
W
W
a
CD
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 FAX: (979) 764 ,3496
----------------------------------------------------------------------------
Application Number . . . . . 07-00000537 Date 3/05/07
Property Address . . . . . . 1010 FALLBROOK LOOP
Property ID: 005401-0512-0060
R #•
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . WESTFIELD VILLAGE PH 5
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . PLANNED DEVL HOUSING
Application valuation . . . . 109230
Owner Contractor
------------------------ ------------------------
STYLECRAFT BUILDERS
4090 SH 6 S
COLLEGE STATION TX 77845
(979) 690-1222
--- Structure Information 000 000 SINGLE FAMILY
Construction Type . . . . .. COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info . . . . . EXTERIOR WALL TYPE MASONRY
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 1655.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 2.00
NUMBER OF BEDROOMS 3.00
SEWER TYPE PUBLIC
TAZ 405.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . . NC
Permit Fee . . . . 490.00 Plan Check Fee .00
Issue Date . . . . 3/05/07 Valuation . . . . 109230
Expiration Date . . 9/01/07
Qty Unit Charge Per Extension
BASE FEE 460.00
10.00 3.0000 THOU BLDG, VAL 100001-500000 30.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 2211
-------------------------------------- ----- -- ---.- ----------
BUILDING DEPT R RES NT.LTIVE�_,
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number
07-00000537
Page 2
Date 3/05/07
Special Notes and Comments
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
BUILDING DE
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number
07-00000537
Page 3
Date 3/05/07
Special Notes and Comments
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
AN APPROVED DEVICE FOR THERMAL EXPANSION C NTROL SHALL BE.
---------------------------- -----------------------�:J• �fe��-------
BUILDING DEPT REP SENTAT V
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page
4
Application Number . . . . . 07-00000537 Date.
3/05/07
----------------------------------------------------------------------------
Special Notes and Comments
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND
CLOTHES DRYERS.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
------------------------------
---------------------------
Permit Fee Total 490.00 490.00 .00
.00
Plan Check Total .00 .00 .00
.00
Other Fee Total 750.00 750.00 .00
.00
Grand Total 1240.00 1240.00 .00
.00
BUILDING DEPT RE
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number 07-00000538 Date 3/05/07
Property Address 1010 FALLBROOK LOOP
Property ID: 005401-0512-0060
R #.
Application type description TEMP POLE
Subdivision Name . . . . . . WESTFIELD VILLAGE PH 5
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . PLANNED DEVL HOUSING
Application valuation . . . . 0
Owner
Contractor
------------------------
------------------------
STYLECRAFT BUILDERS
4090 SH 6 S
COLLEGE STATION
TX 77845
(979) 690-1222
----------------------------------------------------------------------------
Permit . . . . .
. TEMP POLE
PERMIT
Additional desc .
. NC
Permit Fee . . .
. 20.00
Issue Date . . .
. 3/05/07
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary
Charged
Paid Credited
------------------------------
Due
-----------------
Permit Fee Total
----------
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
-------------------
BUILDING DE
APPLICANT:
For Ofdm use Ony
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX
P1=dnZd-Dnx1qpm.-nt_',mica WWW.CSTX.GOV
DATE. TRCC REG
APPLICATION # M
TEMP POLE # M ' J O
ADDRESS/LOCATION: 1010 CAc..I,3000X
LOT 62 ' BLOCK i 2 /SUBDIVISION- InI E5� �i�u7 �ILr aG�C / SEC/PH S
BUSINESS/OWNER NAME. STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120
CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120
CONTRACTOR ADDRESS: 4090 State Highway 6 South
ELECTRICIAN: Brazos Valley Electric PLUMBER: Bass Plumbing
HVAC: Control Temp GOOD CENTS (Residential only): No
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) H
NEW CONSTRUCTION * SLAB ONLY
DUPLEX (Landscape Plans REMODEURENOVATION* SWIMMING POOL
Required)
DESCRIPTION OF WORK: _ Conventional Framing
STRUCTURE USE: Single Family Residence
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECTEGISTRATION# EABPRJ N/A
VALUATION: $ 'i`�Cl TOTAL AREA: 21-7 5 HEATED AREA: 1655
(Cost of Labor and Materials)
QX PUBLIC SEWER
_ \ SEPTIC/TREATMENT SYSTEM .
OX SEWER TAP:
4°
SIZE
® WATER TAP:
Y4"
SIZE
OTHER TAP:
FX TEMP POLE
7 �'J
�j GARAGE TYPE:
`I -
NUMBER OF BEDROOMS: 7
NUMBER OF BATHROOMS: Z
INTERIOR WALL TYPE: Sheet Rock
EXTERIOR WALL TYPE: Siding and/or Masonry
FOUNDATION TYPE: Slab on Grade
ROOF TYPE: Composition
SINGLE F__j DOUBLE F-1 TRIPLE
ATTACHED ] DETACHED a CARPORT
SIGNATURE OF APPLICANT: For Stylecraft
*If proposed work involves new commercial construe 1 n or fac de improvements/renovations to an existing
commercial property, building elevations are required.
00000♦000eeoeooe00000.00000000000000000000000e000000000000000
Official Use Only
—7—e 3 —1-� 0 7 CID eNO
zrp /Mans Examiner _ Zoning Official
Energy Code Compliance Information
% Glazing of exterior walls M %'/
Insulation R value of exterior walls R13 /
Insulation R value of ceiling 1 (flat areas). R30
Insulation R value of ceiling 2 (vaulted areas/no attic) R19
Glazing SHGC .40
Glazing U-Factor .65
R value of ductwork R6
A./C SEER. Rating 13
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# O 7 ` S37
DATE: 3 _' —0
BUILDING ADDRESS:
I. Foundation Requirement
higa
A.
Concrete minimum f c of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F.
Wood foundation details indicated
OK
II. Framing: Floor, Wall, Ceiling and Roof Requirements
N
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
OK
1. One -hour rated extending to roof deck
OK
E.
Header sizes indicated on plans
A/
F.
Emergency bedroom egress
1. Exit direct to outside
2. O enable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
O enable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing plan or elevation shown
K.
Ceiling joist size, spacing, rade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
4
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
III. Stairway Requirements
OK
7
A. Stairway Details
OK
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than twenty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements to be indicated onplans)
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening ? 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
NA/Jr)
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Are fault protection for bedroom circuits
5. Panel location
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
N O
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
NA/
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
Vill. Energy Requirements
N
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
NA/
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N
Maximum drive width for residence is 28' combined for circular
Minimum 30 feet from driveway to side(intersecting) street
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
NAM
Does not block any water course or divert any flow
Elevation certificate needed
,, p+
"APPROVED PLANS PER IRC SECTION R106.3.1."
PLANS EXAMINER
-o7
DATE
,/
a
ciREScheck Software Version 3.7.3
'�( Compliance Certificate
Project Title: PLAN #1650
Report Date: 02/28/07
Data filename: S:\ACAD\Archived\Old REScheck\1 650931 Crested Point.rck
Energy Code: 2003 IECC
Location: College Station, Texas
Construction Type: Single Family
Glazing Area Percentage: 19%
Heating Degree Days: 1788
Construction Site:
Permit Date: 2-28-2007
Owner/Agent:
CHEEMA
1010 FALLBROOK
College Station, TX 77845
Permit #
Permit Date
Designer/Contractor:
Stylecraft Builders, Inc.
4090 St. Hwy. 6 S.
College Station, TX 77845
Compliance: Passes Maximum UA: 583 Your Home UA: 557 --> 4.5% Better Than Code (LIA)
Maximum SHGC: •0 •i
Ceiling 1: Flat Ceiling or Scissor Truss:
Ceiling 2: Cathedral Ceiling (no attic):
Wall 1: Wood Frame, 16" o.c.:
Window 1: Metal Frame, Double Pane with Low-E:
SHGC: 0.40
Door 1: Solid:
Door 3: Solid:
Door 2: Glass:
SHGC: 0.40
Floor 1: Unheated: , Insulation Depth: 0.0'
Air Conditioner 1: Electric Central Air: 12 SEER
Furnace 1: Forced Hot Air: 80 AFUE
1333 30.0
0.0
47
338 19.0
0.0
18
1504 13.0.
0.0
97
262
0.650
170
18
0.500
9
20
0.500
10
18
0.580
10
188
0.0
196
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2003 IECC requirements in
RESchg-ckVersion 3.7.3 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
ST�ILECP_A>~ t R u lt_nt;�5 2 2s o�
Builder/Designer Company Name Date
PLAN #1650