HomeMy WebLinkAboutRES2007-00535, 07-536on I PREPARED 6/05/07, 11:19:32 INSPECTION TICKET PAGE 6 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 6/05/07 ------------------------------------------------------------------------------------------------ ADDRESS 1009 FALLBROOK LOOP SUBDIV: WESTFIELD VILLAGE PH 5 CONTRACTOR STYLECRAFT BUILDERS PHONE (979) 690-1222 OWNER . . PHONE PARCEL . . 005401-0513-0130 APPL NUMBER: 07-00000535 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 3/22/07 OC BLDG, FOUNDATION -SLAB TIME: 17:00 3/22/07 AP March 21, 2007 4:59:32 PM glsouth. Strings On Setbacks O.K. Slab Ground Installed B115 01 4/20/07 RH BLDG, FRAMING TIME: 17:00 4/20/07 AE April 18, 2007 12:22:19 PM kwolfe. 04/20/2007 12:07 PM RH PDA need shots on interior wall plates every 1611 B130 01 4/24/07 RH BLDG, INSULATION TIME: 17:00 4/24/07 DP April 24, 2007 11:15:34 AM glsouth. 04/24/2007 02:28 PM RH PDA Seal all ext. wall cavities and cracks. Do not overstuff insulation. Check the back two corners at the ceiling and elsewhere. B130 02 4/26/07 OC BLDG, INSULATION TIME: 17:00 4/26/07 AP April 25, 2007 3:04:39 PM glsouth. B132 01 4/27/07 OC BLDG, SHEETROCK FASTENER TIME: 17:00 4/27/07 AP April 26, 2007 4:32:02 PM kwolfe. BI2`5 01 6/05/07 BI n BLDG, FINAL TIME: 17:00 ` ,/07 � r June 5, 2007 10:07:28 AM glsouth. -------------------------------------- COMMENTS AND NOTES --------------------------- NO Date: 6/6/2007 Inspection Comments for Finals Permit Year: 7 Permit Number: 535 Address: 1009 FALLBROOK LOOP Insp. Inspection Type Code Description p. status Inspection Result Comments B100 BLDG, FOUNDATION -SLAB IC Strings On Setbacks O.K. B100 BLDG, FOUNDATION -SLAB IC Slab Ground Installed B115 BLDG, FRAMING IC 04/20/2007 12:07 PM RH PDA B115 BLDG, FRAMING IC need shots on interior wall plates every 16" B130 BLDG, INSULATION IC 04/24/2007 02:28 PM RH PDA B130 BLDG, INSULATION IC Seal all ext. wall cavities and cracks. Do not overstuff B130 BLDG, INSULATION IC insulation. Check the back two corners at the ceiling and B130 BLDG, INSULATION IC elsewhere. P100 PLBG, ROUGH IN IC March 19, 2007 4:45:46 PM kwolfe. Page 1 WF0878589 / 001 City of CollegeL.Station PAGE REQ. DATE: 03/05/07 03/05/07 13:52:03 LOCATION: 1009 FALLBROOK LOOP LOC ID: 203916 REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN REQ USER: NCOCHRAN AUTH USER:NCOCHRAN WRK TYPE: 3/4" WTR TAP 4" SWR TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 03/05/07 SCHED COMPLETION: 03/05/07 ******************************************************************************** JOB ORDER RESULT COMMIIQ'I'S (6/7/2007) Gina Southerland - Re: Calling for C.O. @ 1009 Fallbrook Loop Page 1 From: Paul Schoenfeld To: Benjamin McCarty; Chris Haver; Gina Southerland; Joe Garcia; Kim Wol... Date: 6/7/2007 10:39 AM Subject: Re: Calling for C.O. @ 1009 Fallbrook Loop All ok. Paul >>> Gina Southerland 6/6/2007 11:55 AM >>> BP# 07-535 Gina Southerland CSR - Planning & Development Services City of College Station 979-764-3570 www.cstx.gov FINISHING NOTES 1. BACK DOOR WITH INTERNAL BLINDS 2. BLACK MICROHOOD 3. INSULATE LAUNDRY ROOM FOR SOUND 4. 5. 6.. >> =1p;1. AA � .36. 4 p1 cis `___��• ETBACK R ------------- \\ CLEAR & xa0' ---- \\\ PATIO ; I E EW \ \ ` I 1v\ i oQ O\ I lw� IW � 0II— � I 1009 FALLB Lb:b \ WESTFIELI br y, , LOT - 13 37 29' BLOCK - 13 PHASE - 5 C NC. TRUCK MBRCKAIILIBOX O��RIVWEC� WASHOUT HERE . 100 1 SITE PLAN SCALE: 1.=20'-0' LOOP SHEET: G1 AREA SUMMARY cncncnC.,)-cn VI)oVI)or- o � Q �w� �Q wH� OO OwO O 00 N O > 7� p � O W X Q o ►� r--q H W Z �' (� x N 0 o �J v a Q N N N oQzQQ O �WFN u� w WUarxO Q o�,Ww w BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 07-00000535 Date 3/05/07 Property Address . . . . . . 1009 FALLBROOK LOOP Property ID: 005401-0513-0130 R #• Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . WESTFIELD VILLAGE PH 5 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 80190 Owner Contractor ------------------------ ------------------------ STYLECRAFT BUILDERS 4090 SH 6 S COLLEGE STATION TX 77845 (979) 690-1222 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE MASONRY IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1215.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC TAZ 405.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . NC Permit Fee . . . . 384.00 Plan Check Fee .00 Issue Date . . . . 3/05/07 Valuation . . . . 80190 Expiration Date . . 9/01/07 Qty Unit Charge Per Extension BASE FEE 260.00 31.00 4.0000 THOU BLDG, VAL 50001-100000 124.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS OPENING (MINIMUM ROU H-FRAMED SIZE 22" ------------------------------------------- ------ ---� ��ra""_-------- BUILDING DEPT % ZE /NTA�IVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 07-00000535 Page 2 Date 3/05/07 Special Notes and Comments X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the -First 10' feet Away From the Foundation Walls. ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12' If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. BUILDING DE APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 3 Application Number . . . . . 07-00000535 Date 3/05/07 ---------------------------------------------------------------------------- Special Notes and Comments Also assure proper protection of pipe to U.V. light. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN.MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING ST RAGE WATER HEATING ------------- ------------------------------------------------�-- BUILDING DEPT REPRITNNTATIVE:_ APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 4 Application Number . . . . . 07-00000535 Date 3/05/07 ---------------------------------------------------------------------------- Special Notes and Comments EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND CLOTHES DRYERS. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited ------------------------------ Due --------------------------- Permit Fee Total 384.00 384.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1134.00 1134.00 .00 .00 BUILDING DE APPLICANT: TEMPORARY POLE PERMIT CITY OF COLLEGE STATION ° 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 07-00000536 Date 3/05/07 Property Address . . . . . . 1009 FALLBROOK LOOP Property ID: 005401-0513-0130 Application type description TEMP POLE Subdivision Name . . . . . . WESTFIELD VILLAGE PH 5 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 0 Owner Contractor ------------------------ ------------------------ STYLECRAFT BUILDERS 4090 SH 6 S COLLEGE STATION TX 77845 (979) 690-1222 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . NC Permit Fee . . . . 20.00 Issue Date . . . . 3/05/07 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited ------------------------------ Due ----------------- Permit Fee Total ---------- 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 ------------------------------------------------------------- ----------- BUILDING DEPT EP EE\ A: APPLICANT: ror ornm use only APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 9 1101 TEXAS AVENUE ® COLLEGE STATION, TX 77840 CTIYOF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX ?l= ng&Daylopm-nrsrrvica WWW.CSTX.GOV ADDRESS/LOCATION: 1009 FALI_gf2-coK DATE.Qc) may) `TmRCC REG APPLICATION # !�J // ✓�J^ TEMP POLE # r/ ' �✓�-(' LOT i 3 BLOCK 13 ►ISUBDIVISION WE6TFIE1_D V I L ILAC7L: 'O/ -SEC/PH-5 BUSINESS/OWNER NAME:_ STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120 CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120 CONTRACTOR ADDRESS: 4090 State Highway 6 South ELECTRICIAN: Brazos Valley Electric PLUMBER: Bass Plumbing HVAC: Control Temp GOOD CENTS (Residential only): No CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) H NEW CONSTRUCTION * SLAB ONLY DUPLEX (Landscape Plans REMODEURENOVATION* SWIMMING POOL Required) DESCRIPTION OF WORK: Conventional Framing STRUCTURE USE: Single Familv Residence HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ N/A VALUATION: $ E30 c 1q0 ✓ TOTAL AREA: l "7►D HEATED AREA: 121 (Cost of Labor and Materials) qq QX PUBLIC SEWER NUMBER OF BEDROOMS: S q SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: Z �0 ❑X SEWER TAP: 1 4n SIZE OX WATER TAP: 4n SIZE OTHER TAP: / r_ X TEMP SIZE POLE 00 GARAGE TYPE: SINGLE ATTACHED a INTERIOR WALL TYPE: Sheet Rock EXTERIOR WALL TYPE: Siding and/or Masonry FOUNDATION TYPE: Slab on Grade ROOF TYPE: Composition DOUBLE M TRIPLE 0 DETACHED 0 CARPORT SIGNATURE OF APPLICANT. For Stylecraft *If proposed work involves new commercial constructioo or f 6de improvements/renovations to an existing commercial property, building elevations are required. 00000�oeoe0000ee00000.000e00000000000e00000000000000000000000 Official Use Only c-</3 I tiI --,) -7 Plans Examiner Zoning Official ments: Y or NO } Energy Cole Compliance Information % Glazing of exterior walls 12 % Insulation R value of exterior walls R13 Insulation R value of ceiling 1 (flat areas). R30 Insulation R value of ceiling 2 (vaulted areas/no attic) R19 Glazing SHGC .40 Glazing U-Factor .65 R value of ductwork R6 A/C SEER. Rating 131: PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# 07 _ S3 s DATE: 3--1-07 BUILDING ADDRESS: l I. Foundation Requirements N A. Concrete minimum fc of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier Emil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior, unless over 60' long must be 30" 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated eNAYOK II. Framing: Floor, Wall, Ceiling and Roof Requirements A/ A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex K 1. One -hour rated extending to roof deck WAPK E. Header sizes indicated on plans NA/ F. Emergency bedroom egress 1. Exit direct to outside 2. O enable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. O enable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing 2. Moisture barrier indicated on plans 3. Exterior Wall Covering J. Roof framing plan or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size, spacing, roof slope & purlin bracing if required to reduces an O. Roof covering P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only S. All walls within 3' of property line to have protected openings. III. Stairway Requirements OK 17 A. Stairway Details NVOK 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8 B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than twenty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements to be indicated onplans) K A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must meet IRC Chapter 10 Requirements V. Electrical Service Requirements A. Electrical plan to include: NA/9K 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX VI. Plumbing Requirements A. Pressure reducing valve required when water pressure exceeds 80 psi NACOJO B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements NA. A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) VIII. Energy Requirements N A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 N Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements N K Maximum drive width for residence is 28' combined for circular Minimum 30 feet from driveway to side(intersecting) street Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 NKOW Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 N Does not block any water course or divert any flow Elevation certificate needed If L' ' 4 "APPROVED PL PLANS EXAMINER REScheck Software Version 3.7.3 Compliance Certificate Project Title: PLAN #1215A-WV Report Date: 02/28/07 Data filename: S:\ACAD\Archived\Old REScheck\1009 FALLBROOK.rck Energy Code: 2003 IECC Location: College Station, Texas Construction Type: Single Family Glazing Area Percentage: 12% Heating Degree Days: 1788 Construction Site: Permit Date: 2-28-2007 Owner/Agent: PARNELL 1009 FALLBROOK College Station, TX 77845 Permit # Permit Date Designer/Contractor: Stylecraft Builders, Inc. 4090 St. Hwy. 6 S. College Station, TX 77845 Compliance: Passes Maximum UA: 530 Your Home UA: 461 --> 13.0% Better Than Code (UA) Maximum SHGC: 0.40 0.40 Ceiling 1: Flat Ceiling or Scissor Truss: Ceiling 2: Cathedral Ceiling (no attic): Wall 2: Wood Frame, 16" o.c.: Window 4: Metal Frame, Double Pane with Low-E: SHGC: 0.40 Door 3: Solid: Door 5: Glass: SHGC: 0.40 Floor 1: Unheated: , Insulation Depth: 0.0' Air Conditioner 1: Electric Central Air: 13 SEER Furnace 1: Forced Hot Air: 80 AFUE 864 30.0 0.0 30 380 19.0 0.0 20 1376 13.0 0.0 96 150 0.670 101 38 0.500 19 18 0.440 8 179 0.0 187 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2003 IECC requirements in RESc r ion 3.7.3 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. n�_Z- S1-Yt FcJZAFt T vtt_r�,Ef 5 Z 2a o-% Builder/De igner Company Name Date �%J PLAN #1215A-WV Page 1 of 1