HomeMy WebLinkAboutRES2007-00533, 07-5340� 533
U�- 534 C�e.y�i
0
WFO877950 / 001 City�of�`Collede Station PAGE 1
REQ. DATE: 03/01/07 `p4 03/01/07 11:28:27
LOCATION: 3903 BRIDGEBERRY CT LOC ID: 203738
REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN
REQ USER: KWOLFE AUTH USER:KWOLFE WRK TYPE:
4" SWR TAP 3/4" WTR TAP
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 03/01/07 SCHED COMPLETION: 03/01/07
********************************************************************************
JOB ORDER RESULT COMIENTS
PREPARED 7/25/07, 8:02:46 INSPECTION TICKET PAGE 9
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 7/24/07
------------------------------------------------------------------------------------------------
ADDRESS . : 3903 BRIDGEBERRY CT SUBDIV:
CONTRACTOR STYLECRAFT BUILDERS PHONE (979) 690-1222
OWNER . . PHONE
PARCEL . . 650730-0409-0020
APPL NUMBER: 07-00000533 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 3/27/07 OC BLDG, FOUNDATION -SLAB TIME: 17:00
3/27/07 AP March 27, 2007 2:04:53 PM ncochran.
March 27, 2007 2:06:36 PM ncochran.
B115 01 5/02/07 RH BLDG, FRAMING TIME: 17:00
5/02/07 AE May 2, 2007 11:44:25 AM glsouth.
05/02/2007 03:18 PM RH PDA
Need joist hangers at attic access. Draftstop pony wall at
far left arch. Add nails to x-brace in closet.
B130 01 5/04/07 JGM BLDG, INSULATION TIME: 17:00
5/04/07 AP May 4, 2007 11:18:16 AM ncochran.
B132 01 5/08/07 OC BLDG, SHEETROCK FASTENER TIME: 17:00
5/08/07 AP May 8, 2007 8:08:47 AM glsouth.
B125 01 7/24/07 BI BLDG, FINAL TIME: 17:00
i�oZ'S July 24, 2007 4:35:58 PM acarter.
-------------------------------------- COMMENTS AND NOTES--------------------------------------
SHEET INDEX
COVER SHEET
G-1
SITE PLAN
C-1
FLATWORK DETAILS
C-2
FOUNDATION PLAN
S-1
DIMENSION PLAN
S-2
FRAMING PLAN
S-3
ROOF FRAMING PLAN
S-4
DECKING LAYOUT
S-5
FRAMING DETAILS
S-6
FLOOR PLAN
A-1
DETAILS
A-2
ELEVATIONS
A-3
CABINET LAYOUT
A-4
FLOORING PLAN
A-5
ELECTRICAL PLAN
E-1
3903 BRIDGEBERRY COURT
WESTFIELD VILLAGE
LOT - 2
BLOCK - 9
PHASE - 4
VERSION
# DATE REVISION
0 8/25 MASTER APPROVED
1 1 /11 /07 CHANGED 2X6 CEILING JOISTS TO #3 YELLOW PINE
1 FRONT ELEVATION
SCALE: 3/16'=1'-0'
G-1
SUMMAR
p
IV FINISHING NOTES
1. APPLIANCE ALLOWANCE AT BUDDY'S
2. LARGE LOT SPRINKLER SYSTEM
3. DOUBLE GATE AT REAR
4. 50-GAL. WATER HEATER
5.15 ADDITIONAL PALLETS OF SOD
6.
- �- 47L6�?' E
-6" A GATE
-7
p
1 NO PUMP TRUCK /
1 1
1 1
1 1
1
1 `ram
1 u?�
� 1
1 1
1
1
1
� UI
' QI
�1
7 `1
7 r 1
0 1
.wl
zl
� 1
1 1
1
1
1
� 1
I 1
1
1
1
1 1
1
I 1
1
1
1
� 1
1 1
1
1
1
� 1
1
u
:)NC. TRUCK
WASHOUT
L, HERE 90
es-
NEEDED,ACCESS
VIA ALLEY
LOT IS CLEAR
a a'�1-a
CONC.T
PATIO
"/ j 1 T-6-1 '
iPROPOSED
9, /RESIDENCE
I / /
I /
I /
I /
TWO CAR ;
GA GE /
H USE WILL /
E D TO START I
ZHE-G D /
as AT HE,�RON
® 0-1 8ET13 K_
do �1 i
N / 3903 BRIDGEBERRY COURT
WESTFIELD VILLAGE
A' LOT-2
34_ 2_1 , BLOCK-9
% PHASE-4
E AIILIBOX
1 SITE PLAN
SCALE: 1'=20'-0"
SHEEP:
C-1
.. .
Amber Carter- Re Calling for C.O. @ 3903 Bridgeberry
From: Mitchell Carson
To: Amber Carter; Benjamin McCarty; Chris Haver; ...
Date: 7/25/2007 4:00 pm
Subject: Re: Calling for C.O. @ 3903 Bridgeberry Ct.
THIS ONE IS OK MITCH
>>> Gina Southerland 07/25/07 8:26 AM >>>
BP# 07-533
Gina Southerland
CSR - Planning & Development Services
City of College Station
979-764-3570
www.cstx.gov
BUILDING PERMIT .
CITY OF COLLEGE STATION
3,141--'!'EXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
--------------------------------- -------------------------------------------
Application Number . . . . . 07-00000533 Date 3/01/07
Property Address . . . . . . 3903 BRIDGEBERRY CT
Property ID: 005401-0409-0020
R #.
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . WESTFIELD VILLAGE PH 4
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . PLANNED DEVL HOUSING
Application valuation . . . . 104874
Owner
Contractor
------------------------
------------------------
STYLECRAFT BUILDERS
4090 SH 6 S
COLLEGE STATION
TX 77845
(979) 690-1222
--- Structure Information
000 000 SINGLE FAMILY
Construction Type .
. . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . .
. . . . RESIDENTIAL-SFR/DUPLEX
Other struct info .
. . . . EXTERIOR WALL TYPE
MASONRY
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
1589.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
2.00
NUMBER OF BEDROOMS
3.00
SEWER TYPE
PUBLIC
TAZ
405.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
KW
Permit Fee . . . .
475.00 Plan Check Fee
.00
Issue Date . . . .
3/01/07 Valuation . .
. . 104874
Expiration Date . .
8/28/07
Qty Unit Charge Per Extension
BASE FEE 460.00
5.00 3.0000 THOU BLDG, VAL 100001-500000 15.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 2211
-
------------------------------------
-------- --- ----- -------_-------
BUILDING DEPT REPRESENTATIVE: ----
APPLICANT: ��
BUILDING PERMIT
CITY OF COLLEGE STATION
1.101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page 2
Application Number . . . . . 07-00000533 Date 3/01/07
----------------------------------------------------------------------------
Special Notes and Comments
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
---------------------------------------------------- ------ ---------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT: C"
BUILDING PERMIT
CITY OF COLLEGE STATION
.1101 }TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 3
Application Number . . . . . 07-00000533 Date 3/01/07
----------- ----------------------------------------------------------------
Special Notes and Comments
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
------------------------------------------------- ------ -----,-----------
BUILDING DEPT REPR SENTATIVE:
APPLICANT: or
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page
4
Application Number . . . . . 07-00000533 Date
3/01/07
----------------------------------------------------------------------------
Special Notes and Comments
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND
CLOTHES DRYERS.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------------------------------
-----------------
Permit Fee Total 475.00 475.00 .00
.00
Plan Check Total .00 .00 .00
.00
Other Fee Total 750.00 750.00 .00
.00
Grand Total 1225.00 1225.00 .00
.00
--------------------------------------------------= ----- --- ----- _ ----
BUILDING DEPT REPRESENTATIVE:
1) n A ,
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 'TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number 07-00000534 Date 3/01/07
Property Address . . . . . . 3903 BRIDGEBERRY CT
Property ID: 005401-0409-0020
R #.
Application type description TEMP POLE
Subdivision Name . . . . . . WESTFIELD VILLAGE PH 4
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . PLANNED DEVL HOUSING
Application valuation 0
Owner Contractor
------------------------ ------------------------
STYLECRAFT BUILDERS
4090 SH 6 S
COLLEGE STATION TX 77845
(979) 690-1222
----------------------------------------------------------------------------
Permit . . . . . . TEMP POLE PERMIT
Additional desc . . KW
Permit Fee . . . . 20.00
Issue Date . . . . 3/01/07 Valuation . . . . 0
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
---------------------------------------------------------
Permit Fee Total 20.00 20.00 .00 .00
Grand Total 20.00 20.00 .00 .00
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
.F. APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
CTIYOF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX
Pl= ng&DnxGpmmtSemi= WWW.CSTX.GOV
ADDRESS/LOCATION: 3 `t0 -�
,/ CA
For Of a Use Ony
DATE. U ` ANTRCC REG�
APPLICATION # v � — `� 3
TEMP POLE # 0 7 53
LOT1,/ BLOCK _ l v SUBDIVISION WIES7 FIELQ VILt,P4aC SEC/PH 1 `!
BUSINESS/OWNER NAME:_ STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120
CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120
CONTRACTOR ADDRESS: 4090 State Highway 6 South
ELECTRICIAN: Brazos Valley Electric PLUMBER: Bass Plumbina
HVAC: Control Temp GOOD CENTS (Residential only): No
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) H
NEW CONSTRUCTION * SLAB ONLY
DUPLEX (Landscape Plans REMODEURENOVATION* SWIMMING POOL
Required)
DESCRIPTION OF WORK: Conventional Framing
STRUCTURE USE: Single Familv Residence
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ N/A
VALUATION: $ IoN 67q w/ TOTAL AREA: Z17H HEATED AREA: 1-158l
(Cost of Labor and Materials)
15 QX PUBLIC SEWER
SEPTIC/TREATMENT SYSTEM
® SEWER TAP:
OX WATER TAP:
OTHER TAP:
W X OTEMP POLE
GARAGE TYPE:
SIZE
4n
SIZE
SIZE
SINGLE
ATTACHED
NUMBER OF BEDROOMS: )
NUMBER OF BATHROOMS: Z
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
DOUBLE t�
IETACHED 1 1
TRIPLE
CARPORT
Sheet Rock
Siding and/or Masonry
Slab on Grade
COmDosition
W
SIGNATURE OF APPLICANT: / For Stylecraft
*If proposed work involves new commercial constructi n or f ade improvements/renovations to an existing
commercial property, building elevations are required.
oo®0000eo000000e00000.00000000000000000000000e000000000000000
Official Use Only
34
Plans Exriner
�Ga Wlf4 F/P
Zoning Official
Comments.
�rNO
Energy Code Compliance In r aa�ion
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas).
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor
R value of ductwork
A/C SEER. Rating
� 3 %
✓
0
R13
R30
R19 /
.40
.65
R6
131=/
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# S3 3
DATE: I 0�
BUILDING ADDRESS:
I. Foundation Requirements
N
A.
Concrete minimum f'c of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F.
Wood foundation details indicated
N
II. Framing: Floor, Wall, Ceiling and Roof Requirements
N O
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
K
1. One -hour rated extending to roof deck
OK
E.
Header sizes indicated on plans
K
F.
Emergency bedroom egress
1. Exit direct to outside
2. O enable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
O enable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
lll. Stairway Requirements
OK
A. Stairway Details
KMK
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than twenty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements to be indicated onplans)
N
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
N K
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
N
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
Vill. Energy Requirements
NA(019
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N
Maximum drive width for residence is 28' combined for circular
Minimum 30 feet from driveway to side(intersecting) street
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
N
Does not block any water course or divert any flow
Elevation certificate needed
A'
"APPROVED PLANS PER IRC SECTION R106.3.1."
PLANS EXAMINER
DATE
REScheck Software Version 3.7.3
Permit #
Permit Date
Compliance Certificate
Project Title: Plan # 1586 WVCO
Report Date: 02/28/07
Data filename: S:\ACAD\Archived\Old REScheck\3903 BRIDGEBERRY.rck
Energy Code:
2003 IECC
Location:
College Station, Texas
Construction Type:
Single Family
Glazing Area Percentage:
13%
Heating Degree Days:
1788
Construction Site:
Owner/Agent:
Permit Date: 07-06-2006
Maximum SHGC: 0.40 Your SHGC: 0.40
Ceiling 1: Flat Ceiling or Scissor Truss:
Ceiling 2: Cathedral Ceiling (no attic):
Wall 1: Wood Frame, 16" o.c.:
Window 1: Metal Frame, Double Pane with Low-E:
SHGC: 0.40
Door 1: Solid:
Door 2: Glass:
SHGC: 0.40
Floor 1: Slab -On -Grade: Unheated: , Insulation Depth: 0.0'
Air Conditioner 2: Electric Central Air: 13 SEER
Furnace 2: Forced Hot Air: 80 AFUE
Designer/Contractor:
1451 30.0
0.0
51
135 19.0
0.0
7
1483 13.0
0.0
103
175
0.670
117
38
0.500
19
18
0.440
8
174
0.0
181
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2003 IECC requirements in
RE ehecl Version 3.7.3 a to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
�T�4LEc,+2aF'` f3�tl.-f�ER� ZI28 0�
Builder/Designer "L,"/Company Name Date
Project Notes:
Previously saved project information:
ROGNERUD
3903 BRIDGEBERRY
College Station, Texas
Stylecraft Builders, Inc.
4090 St. Hwy. 6 S.
College Station, Texas 77845
Plan # 1586 WVCO
Page 1 of 1