Loading...
HomeMy WebLinkAboutRMDL2007-0052007--1520 I: nn�t Dater Permit #—�� Project Name C )OMMERCIAL CO Planning V a C (Lindsay Boyer, Jennifer Prochazka, Jennifer Reeves, Cri artl, Jason Schubert, i Bridgette George Development Engineers (Alan Gibbs, Josh Norton, Carol Cotter) City Engineer (Bob Mosley, Jerry Jones, John Logan, Robert Bumpurs, William Ethridge) Environmental Services (Eaphrame Thomas, James Boykin, Pete Garcia) Fire Department Kll�pw (Eric Hurt, Eric Dotson, Jerry Duffey, Steve Smith) Drainage (Donnie Willis) Public Works - Sanitation (Wally Urrutia) Electrical Services (Tony Michalsky) Miscellaneous Notes PREPARED 4/26/07, 8:04:38 INSPECTION TICKET PAGE 11 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 4/25/07 ----=------------------------------------------------------------------------------------------- ADDRESS . : 101 DOWLING RD SUBDIV: CRAWFORD BURNETT (ICL) TENANT, NBR: REMODEL OF RESTURANT CONTRACTOR J-LAW CORPORATION PHONE (979) 224-2577 OWNER JONES, EDSEL G PHONE PARCEL 000701-0068-0000 APPL NUMBER: 07-00000520 COMMERCIAL, REMODEL/RENOVATION ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B115 01 3/08/07 OC BLDG, FRAMING TIME: 17:00 3/14/07 AP March 8, 2007 2:55:51 PM ncochran. March 14, 2007 2:00:07 PM glsouth. B 5 01 4 2 07 BLDG, FINAL TIME: 17:00 April 25, 2007 1:59:12 PM kwolfe. -- CONTINUED ONTO NEXT PAGE b:- Date: 4/26/2007 Inspection Comments for Finals Permit Year: 7 Permit Number: 520 Address: 101 DOWLING RD insp. Type Inspection Type Code Description Insp. status Inspection Result Comments B115 BLDG, FRAMING IC March 14, 2007 2:00:07 PM glsouth. E130 ELEC, WALL COVER UP IC 03/13/2007 04:15 PM JGM PDA E130 ELEC, WALL COVER UP IC door locked E130 ELEC, WALL COVER UP IC April 13, 2007 4:48:17 PM ncochran. P125 PLBG, FINAL IC 04/09/2007 12:25 PM DS PDA P125 PLBG, FINAL IC in -direct waste for 3 compartment sink T&P backfall P125 PLBG, FINAL IC coming out of wall needs to insulate drains on handsinks P125 PLBG, FINAL IC needs open front seats on water closet front hand sink P125 PLBG, FINAL IC leaking P125 PLBG, FINAL IC April 13, 2007 4:48:46 PM ncochran. Page 1 (4/25/2007 Kim Wolfe - Re: Calling for CO @ 101 Dowling Rd (Remodel of reestaurant) Page 1 From: Steve Smith To: Alan Gibbs; Benjamin McCarty; Bob Mosley; Carol Cotter; Charles Will... Date: 4/25/2007 4:23 PM Subject: Re: Calling for CO @ 101 Dowling Rd (Remodel of restaurant) They need address and "No Smoking" sign. The rest of it looks good. >>> Kim Wolfe 04/25/07 2:04 PM >>> Are there any issues? Contact: Karen @ 224-2577 BP # 07-520 Thanks Kimberly Wolfe, CPS City of College Station Planning & Development Services (979)764-3570 www.cstx.gov 4/25/2007) Kim Wolfe - Re: Calling for CO G 101 Dowling Rd Remodel of restaurant Page 1 From: Tony Michalsky To: Kim Wolfe Date: 4/25/2007 2:18 PM Subject: Re: Calling for CO @ 101 Dowling Rd (Remodel of restaurant) okay with us >>> Kim Wolfe 4/25/2007 2:04 PM >>> Are there any issues? Contact: Karen @ 224-2577 BP # 07-520 Thanks Kimberly Wolfe, CPS City of College Station Planning & Development Services (979)764-3570 www.cstx.aov (4/25/2007) Kim Wolfe - Re: Calling for CO @ 101 Dowling Rd (Remodel of restaura t) Page 1 From: Donnie Willis To: Wolfe, Kim Date: 4/25/2007 2:09 PM Subject: Re: Calling for CO @ 101 Dowling Rd (Remodel of restaurant) OK with Drainage. Donnie Willis, CFM Environmental Engineering Technician Certified Floodplain Manager Public Works Department 979-764-6375 office 979-229-7632 cell dwillis@cstx.gov >>> On 4/25/2007 at 2:04 pm, in message<462F5FFA.38F0.0012.0@cstx.gov>, Kim Wolfe wrote: Are there any issues? Contact: Karen @ 224-2577 BP # 07-520 Thanks Kimberly Wolfe, CPS City of College Station Planning & Development Services (979)764-3570 www.cstx.gov t b� szo `.O College Station Fire Department INSPECTION/TEST REQUEST Location of Inspection/Test: 101` A N wL i n q G�I&y 5/4; �:a, ,7X 77{,S yS" J � Business/Job Phone: Applicant Name: %� r� doh f ` �e S y S¢Z,rh s Address: 75 75 c � a r,a; oY Ln . A-/w,,46 ,_r� 773 9i� Phone: 2 9 A/`/l - 9$S0 Date of Application: 3 22-o-7 INSPECTION/TEST FEE AMT. DUE Day Care Inspection......................................................................... $30.00 .............. $ Foster Home Inspection................................................................... $30.00 .............. $ Nursing Home Inspection................................................................. $50.00 .............. $ Health Care Facility Inspection . $50.00 .............. $ Fire Sprinkler/Standpipe Test, up to 100.......................................... $50.00 .............. $ Each 100 thereafter, or fraction ..... # heads @ $50.00/100 .............. $ Automatic Hood Fire Extinguisher Test ............................................ $30.00 $ Fuel Tank Leak Test......................................................................... $50.00 .............. $ Fuel Line Leak Test.......................................................................... $50.00 .............. $ Automatic Fire Alarm System Test, up to 25 initiating devices ......... $30.00 .............. $ Each 100 thereafter, or fraction .... # devices @ $50.00/100 .............. $ Natural Gas System Test.................................................................. $30.00 .............. $ Inspections Outside City Limits Standard Fee: x 1.5 = Vehicle Mileage: x 0.325 = Total Travel Time: x 20.00 = Total Inspection Fee: $ TOTAL AMOUNT DUE: $ 3 d • 00 PLEASE NOTE: Re -tests and re -inspections will be billed at the same rate as the initial test or inspection. White: Applicant Yellow: Fire Marshal Pink: Building CITY OF CMIEE STATION REPRINT aeff GUST ER RRMFT NCOCHRIN TYPe: CT Drawer: I 3122/07 go Receipt no: 19M4@ Description Quaritit Anount E7 AUTO mom &/m I.0 $30.03 FIRE ms, INC FIREW TEST jNSECTION WC CHI 15886 Tender detail CK PERSONAL 158% go Total tendered Total pkvmt $39.09 $39.90 Tram date. 3/22M TiMP. THANX YOU City of College.Station 1101 TEXAS AVENUE COLLEGE STATION TX 77840 C E R T I F I C A T E O p O C C U P A N C Y P E R M A N E N T Issue Date . . . . Parcel Number . . . . . Property Address . . . Subdivision Name . . . Legal Description . . . Property Zoning . . . . Owner . . . . . . . . . Contractor . . . . . . Application number Description of Work . Construction type . . . Occupancy type . . . . Flood Zone . . . . . . 4/27/07 000701-0068-0000 101 DOWLING RD COLLEGE STATION TX 77845 CRAWFORD BURNETT (ICL) A000701 CRAWFORD BURNETT (ICL) TRACT 68, ACRES 1.0 PLANNED -COMMERCIAL JONES, EDSEL G J-LAW CORPORATION 979 224-2577 07-00000520 000 000 COMMERCIAL, REMODEL/RENOVATION COMBUSTIBLE (UNPROTECTED) ASSEMBLY ( IBC) Approved . . . . . . . ���� Bui�Iding Official VOID UNLESS SIGNED BY BUILDING OFFICIAL (AW City of College Station Page of Building Inspection Department PLANS EXAMINATION REPORT Address: IOI rv�..�.4.� ,Q�.,� Date: ZZZf,/o Project Name: Drawing Number Code Ref. Number Questions or Comments �K liia "1 Noa-/ - 5 fi.,e Goolr Ord •�,� �-, o� j'. nrlAil �� /�K 6 v Received by: 4/30/2007) Kim Wolfe - Re: Calling for CO @ 101 Dowling Rd (Remodel of restaurant) Page 1 From: Lindsay Boyer To: Alan Gibbs; Benjamin McCarty; Bob Mosley; Carol Cotter; Charles Will... Date: 4/26/2007 4:50 PM Subject: Re: Calling for CO @ 101 Dowling Rd (Remodel of restaurant) planning is good for CO. >>> Kim Wolfe 4/25/2007 2:04 PM >>> Are there any issues? Contact: Karen @ 224-2577 BP # 07-520 Thanks Kimberly Wolfe, CPS City of College Station Planning & Development Services (979) 764-3570 www.cstx.00v 4/27( /2007) Kim Wolfe - Re: Calling for CO @ 101 Dowling Rd (Remodel of restaurant) Page 1 From: Eaphrame Thomas To: Alan Gibbs; Benjamin McCarty; Bob Mosley; Carol Cotter; Charles Will... Date: 4/27/2007 9:06 AM Subject: Re: Calling for CO @ 101 Dowling Rd (Remodel of restaurant) CC: Eaphrame Thomas They are good for CO no issues. Eaphrame A. Thomas Environmental Technician Water Services Department Environmental Services 979.764.3662 Have A Wonderful Bless Day:) >>> Kim Wolfe Wednesday, April 25, 2007 2:04 pm >>> Are there any issues? Contact: Karen @ 224-2577 BP # 07-520 Thanks Kimberly Wolfe, CPS City of College Station Planning & Development Services (979) 764-3570 WWW.cstx.gov BUILDING PERMIT CITY OF--eO,L--E'EGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . Property Address . . . . . . Property ID: R #: Tenant nbr, name . . . . . . Application type description Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . Application valuation . . . . 07-00000520 101 DOWLING RD 000701-0068-0000 R10441 Date 3/01/07 REMODEL OF RESTURANT COMMERCIAL, REMODEL/RENOVATION CRAWFORD BURNETT (ICL) UNKNOWN 20000 Owner Contractor ------------------------ ------------------------ JONES, EDSEL G OWNER 310 UNIVERSITY DR E COLLEGE STATION TX 778401730 --- Structure Information 000 000 REMODEL OF EXISTING RESTAURANT Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . ASSEMBLY (IBC) Other struct info . . . . . IMPACT/PRORATA FEES PAID NA HEATED AREA 2170.00 INTERIOR WALL TYPE SHEETROCK TAZ 396.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . KW Permit Fee . . . . 110.00 Plan Check Fee .00 Issue Date . . . . 3/01/07 Valuation . . . . 20000 Expiration Date . . 8/28/07 Qty Unit Charge Per Extension BASE FEE 15.00 19.00 5.0000 THOU BLDG, VAL 1001-50000 95.00 ---------------------------------------------------------------------------- Special Notes and Comments PROVIDE ADDRESS ON COMMERCIAL BUILDINGS -FRONT 5" NUMBERS REAR - 2" HIGH NUMBERS WITH NAME OF BUSINESS THE TEXAS DEPARTMENT OF HEALTH REQUIRES AN ASBESTOS SURVEY IN CERTAIN CIRCUMSTANCES - CALL TDH @ (254) 778-6744 FOR MORE INFORMATION Permit Number provided by the COCS shall be conspicuously posted in the lower right hand corner of the banner. Shall be mounted parallel to the face of a building or permanent structure. Shall advertise only the name of, uses of, or goods or ------------- BUILD APPLI BUILDING PERMIT CITY OP COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 2 Application Number 07-00000520 Date 3/01/07 ---------------------------------------------------------------------------- Special Notes and Comments services available within the building or tenant lease space to which the banner is attached. Shall not be located within public road ROW (State or Local) . Shall not obstruct any window, door, stairway, or other opening inteded for ingress or for needed ventilation or light. Shall not exceed the top of the structure to which it is attached. Shall advertise only the name of, uses of, or goods or services available within the building, or tenant lease space, to which the banner is attached. Shall be mounted parallel to the face of the building. Shall not be cantilevered away from the structure. Shall not extend more than one foot from any exterior building face, mansard, awning, or canopy. Shall not obstruct any window, door, stairway, or other opening intended for ingress or for needed ventilation or light. Shall not be attached to any tree, fence, or public utility pole. NOTE FROM WATER DEPT--REDUCED PRESSURE ASSEMBLY REQUIRED FOR CAR WASH, POSTMIX CARBONATER, AND HEATING/AC WITH DIRECT CONNECTION TO WATER SUPPLY AND LAWN IRRIGATION SYSTEMS. ALL DEVICES MUST BE TESTED UPON INSTALLATION BY CERTIFIED TESTER REGISTERED WITH THE CITY OF COLLEGE STATION PUBLIC UTILITIES DEPT. LAWN IRRIGATION MAY USE A PRESSURE VACCUM BREAKER INSTALLED PER AWWA STANDARDS AND CITY'S ORD #2394. ALL DEVICES MUST BE INSTALLED PER AWWA AND CITY'S ORD#2394 PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE PROVIDE FIRE EXTINGUISHERS) - VERIFY LOCATION AND PLACEMENT WITH THE FIRE MARSHALL'S OFFICE (MIN. 2A10BC) Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT All outdoor lighting must be in compliance with Section 7.10, Outdoor lighting Standards of the City's Unified Development Ordinance All roof and ground -mounted mechanical equipment shall be sreened from view or isolated so as not to be visible from BUILD APPLI BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number 07-00000520 Page 3 Date 3/01/07 Special Notes and Comments any public right-of-way or residential district within 150 feet of the subject lot, measured from a point five feet above grade. Such screening shall be coordinated with the building architecture and scale to maintain a unified appearance. Acceptable methods of screening rooftop equipment may include, but are not limited to encasement, parapet walls, or partition screens. COLLEGE STATION ELECTRICAL DIVISION REQUESTS THAT THE METER CAN/ELECTRICAL SERVICE DISCONNECT BE LOCATED ON THE STRUCTURE AS CLOSE AS POSSIBLE TO THE SECONDARY FEEDER CONDUIT FROM THE TRANSFORMER. (see site plan for location of conduit or contact electrical division) CONSTRUCTION ACTIVITY BETWEEN THE HOURS OF 10:00 PM AND 7:00 AM MUST COMPLY WITH THE NOISE ORDINANCE (MAX. 55 DBA) PROVIDE PANIC HARDWARE ON EXIT DOORS If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe to U.V. light. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK PROVIDE KITCHEN EXHAUST HOOD TYPE I, U.L.#300, WITH FIRE SUPPRESSION SYSTEM PER LOCAL FIRE CODES AND ORDINANCES. PROVIDE HOOD AND HOOD DUCT WITH 18 INCHES CLEARANCE FROM COMBUSTIBLE MATERIALS. PROVIDE 60"x 60" LANDINGS AT EXIT DOORS. Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total 110.00 110.00 Plan Check Total .00 .00 Grand Total 110.00 110.00 BUILDING'DIAPTjREPRESEN7AT,IVE: APPLI .00 .00 .00 .00 .00 .00 BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . BUILD APPLI 07-00000520 Page 4 Date 3/01/07 APPLICATION FOR BUILDING PERMIT 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX CITY OF COLLEGE STATION WWW.CSTX.GOV P14nning Cri',Dcve6pment Semicer n n ADDRESS/LOCATION: A41 For Office Use Only DATER*�l *01RCC REG APPLICATION #VQ `E k/ TEMP POLE # LOT BLOCK S BDIVISION SEC/PH BUST. S /OWN R NAME: G /L PHONE: Y(-c r%/ CONT CTOR/HOMEOWNE G'(/ PHONE:0054 CONTRACTOR ADDRESS: A _ ELECTRICIAN: PLUMBER: l HVAC: GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF O� ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION ` SLAB ONLY DUPLEX (Landscape Plans) REMODEL/RENOVATION' SWIMMING POOL TENT/CANOPY /l A n /7 DESCRIPTION OF WORK: PROPOSED USE: HOMEOWNER ASSOCIA-ION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ 4110.vt' VALUATION\$ ,GOB '0od,/ qq TOTAL AREA:G./1D HEATED AREA: (Cost of Labor and Materials) PUBLIC SEWER SEPTIC/TREATMENT SYSTEM SEWER TAP: ❑ WATER TAP: JILt JIZE OTHER TAP: SIZE NUMBER OF BEDROOMS: NUMBER OF BATHROOMS: INTERIOR WALL TYPE: EXTERIOR WALL TYPE: FOUNDATION TYPE: ❑ TEMP POLE ROOF TYPE: GARAGE TYPE: SINGLE F__1 DOUBLE a ATTAD Ej DET CHED F TRIPLE a ,ARPOFY F SIGNATURE OF APPLICA *If proposed work involve syi commerc' I co ructi n or cad Improvem s o ti ns commercial property, buil. Wig elevations are required. Official Use Only Plans Examiner Zoning Official Fire Marshall Co nts: ES o O Energy_.Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER Rating 6gZ ys2 Jay/3a� 3r ,s 7 4 40�"3 zc2-�/3 Sc 1 PLM REPORT Steve Moody Micro Services, Inc. NVLAP Lab No. 102056 2051 Valley View Lane TDH License No. 30-0084 Farmers Branch, TX 75234 (972) 241-8460 PAT ID # 102577 Client: Austin Environmental, Inc. Lab Job No.: x76-01902 Project : Vacant C-Store, 101-A North Dowling, College Station TX Report Date: 02/28/2007 Project # : AE07-48 Sample Date: 02/27/2007 Identification: Asbestos, Bulk Sample Analysis Test Method: Polarized Light Microscopy / Dispersion Staining (PLM/DS) EPA Method 600 / R-93 / 116 Page 1 of 2 On 02/28/2007, twelve (12) bulk material samples were submitted by Brent Plant of Austin Environmental, Inc. for asbestos analysis by PLM/DS. Copies of the lab data sheets are attached; additional information may be found therein. The results are summarized below: Sample Number Client Sample Description / Location Asbestos Content ND-01A Drywall Texture, Side Storage Room, at Ceiling Access Panel None Detected - Drywall Material None Detected - Texture ND-01B Drywall Texture, Retail Area Dining A, None Detected - Drywall Material Next to Return Air Vent to Ceiling None Detected - Joint Compound None Detected - Texture ND-01C Drywall Texture, Dining Room B, Next to Left Side Halogen Light None Detected - Drywall Material None Detected - Texture ND-02A 12" x 12" Floor Tile (Brown Speckled), Dining Room A, None Detected - Floor Tile at Entry, Next to Threshold None Detected - Yellow Mastic ND-02B 12" x 12" Floor Tile (Brown Speckled), Dining Room B, None Detected - Floor Tile Back Right Corner at Door None Detected - Yellow Mastic ND-02C 12" x 12" Floor Tile (Brown Speckled), Kitchen, None Detected - Floor Tile Middle of Back Wall, Under Window None Detected - Yellow Mastic ND-03A Cove Base Mastic, Debris, Outside Dining Room A, Entry None Detected - Cove Base None Detected - Brown Mastic ND-03B Cove Base Mastic, Side Storage Room, Next to Exit Door None Detected - Cove Base None Detected - Brown Mastic ND-03C Cove Base Mastic,. Dining Room A, Behind Counter at Wall None Detected - Cove Base None Detected - Brown Mastic ND-04A Blown -in Insulation, Attic, at Ceiling Access Door, None Detected - Thermal Insulation Storage Room ND-04B Blown -in Insulation, Attic, Middle Above Retail Area None Detected - Thermal Insulation ND-04C Blown -in Insulation, Attic, Northeast Corner in Attic None Detected - Thermal Insulation PLM REPORT Steve Moody Micro Services, Inc. NVLAP Lab No. 102056 2051 Valley View Lane TDH License No. 30-0084 Farmers Branch, TX 75234 (972) 241-8460 PAT ID # 102577 Client: Austin Environmental, Inc. Lab Job No.: x7B-01902 Project : Vacant C-Store, 101-A North Dowling, College Station TX Report Date: 02/28/2007 Project # : AE07-48 Sample Date: 02/27/2007 Identification: Asbestos, Bulk Sample Analysis Test Method: Polarized Light Microscopy / Dispersion Staining (PLM/DS) EPA Method 600 / R-93 / 116 Page 2 of 2 On 02/28/2007, twelve (12) bulk material samples were submitted by Brent Plant of Austin Environmental, Inc. for asbestos analysis by PLM/DS. Copies of the lab data sheets are attached; additional information may be found therein. The results are summarized below: Sample Number Client Sample Description / Location Asbestos Content These samples were analyzed by layers. Quantification, unless otherwise noted, is performed by calibrated visual estimate. Results may not be reproduced except in full. This test report relates only to the samples tested. These test results do not imply endorsement by NVLAP or any agency of the U.S. Government. Accredited by the National Voluntary Laboratory Accreditation Program for Bulk Asbestos Fiber Analysis under Lab Code 102056. W^ ^ ^ V Analyst : Jessica Scott Lab Director: Steve Moody Approved Signatory -------------------------------------------- Thank you for choosing Steve Moody Micro Services--------------------------------------------- •r TEXAS * 'Control No: Department of * 931 Zf State Health Services Department of State Health Sen ices certifies that: IBRENT W PLANT is Licensed as an: Individual Asbestos Consultant J,icense Number: T .0 105636 05/15/1006 05/24/2008 E DEPARTMENT OF STATE HEALTH SERVICES BE IT KNOWN THAT AUSTIN ENVIRONMMNTAL INC. is liceijqed.'and authorized to perform as an in tile st-,W, Of T60s within the purview 0 s 34W.,fided Df revoked a.nd irenewed.' :6 A-AaM te -Milobf* thig cdififipate is -void after ap WIT A A_eA0 C-ons;q1ta'nt Agpey M dhotet IW-,:pq lohg.4 this --licetise is not th6 Toxa s Board bf -Hb*.'.lh- D qlswo z8,f*bk,4- M- pqr of 11Valth rRANSFUL"LE.