Loading...
HomeMy WebLinkAboutRES2007-00516rn-�� PREPARED 6/14/07, 15:43:25 INSPECTION TICKET PAGE 3 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 6/12/07 ------------------------------------------------------------------------------------------------ ADDRESS 5201 BALLYBUNION LN SUBDIV: PEBBLE CREEK CONTRACTOR MARIOTT HOMES PHONE (979) 696-1787 OWNER . . PHONE PARCEL . . 497900-0947-0110 APPL NUMBER: 07-00000516 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------ ------------------------------------------------------------------------- PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 3/13/07 RH BLDG, FOUNDATION -SLAB TIME: 17:00 3/13/07 AP March 13, 2007 8:28:39 AM ncochran. FIRST THING AFTER LUNCH 03/13/2007 04:27 PM RH PDA Strings up, slab ground installed. B145 01 4/10/07 JGM BLDG, EXT. SHEATHING FASTENER TIME: 17:00 ,4/11/07 AP April 10, 2007 2:39:06 PM kwolfe. apa nailing pattern B115 ;ql 4/11/07 JGM BLDG, FRAMING TIME: 17:00 4/11/07 AP April 11, 2007 8:09:05 AM kwolfe. B130 CA 4/12/07 JGM BLDG, INSULATION TIME: 17:00 4/12/07 AP April 12, 2007 9:08_:54 AM glsouth. ' LATE AFTERNOON 04/12/2007 03:35 PM JGM PDA not ready %^ B125 01 6/12/07 pe ���A BLDG, FINAL TIME: 17:00 V �Vw June 14, 2007 9:08:19 AM acarter. -------------------------------------- COMMENTS AND NOTES ------ -------------------------------- (<r� V'\_ cam- .11,erk (6/22/2007) Kim Wolfe - Re: Calling for CO @ 5201 Ballybunion Ln Page 1 From: Terry Boriskie To: Amber Carter; Benjamin McCarty; Chris Haver; Gina Southerland; Joe G... Date: 6/22/2007 2:16 PM Subject: Re: Calling for CO @ 5201 Ballybunion Ln Notified Larry at Mariott Homes of the needed repairs at 696-1787 Terry Boriskie City of College Station Residential Plans Examiner 979-764-3744 >>> Mitchell Carson 6/15/2007 4:16 pm >>> THE BOX ON THE WATER NEEDS TO BE RAISED PLACED A BLUE FLAG BY IT MITCH >>> Kim Wolfe 06/14/07 4:03 PM >>> Any issues? BP# 07-516 Thanks Kimberly Wolfe, CPS City of College Station Planning & Development Services (979)764-3570 www.cstx.gov WF0882806 / 001 City of College Station PAGE 1 REQ. DATE: 03/22/07 03/22/07 10:11:43 LOCATION: 5201 BALLYBUNION LN LOC ID: 205858 REQUESTOR: MARIOTT HOMES ORIGIN: CUSTOMER -WALK IN REQ USER: NCOCHRAN AUTH USER:NCOCHRAN WRK.TYPE: TEMP POLE PASSED TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 03/22/07 SCHED COMPLETION: 03/22/07 ******************************************************************************** JOB ORDER RESULT COMCE TrS ()-�.-51 u WF0878226 / 001 City of College Station PAGE 1 REQ. DATE: 03/02/07 03/02/07 13:47:21 LOCATION: 5201 BALLYBUNION LN LOC ID: `205858 REQUESTOR: MARIOTT HOMES ORIGIN: CUSTOMER -WALK IN REQ USER: NCOCHRAN AUTH USER:NCOCHRAN WRK TYPE: 4" SWR TAP 3/4" WTR TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 03/02/07 SCHED COMPLETION: 03/02/07 ******************************************************************************** JOB ORDER RESULT COW ENTS City of College Station w 1101 TEXAS AVENUE COLLEGE STATION TX 77840 C E R T I F I C A T E O F O C C U P A N C Y P E R M A N E N T Issue Date . . . . . . 6/22/07 Parcel Number 497900-0947-0110 Property Address 5201 BALLYBUNION LN COLLEGE STATION TX 77845 Subdivision Name PEBBLE CREEK Legal Description PEBBLE CREEK 9-D BLK 47 LOT 11 Property Zoning . . . . SINGLE FAMILY RESIDENTIAL Owner . . . . . . . . . Contractor . . . . . . MARIOTT HOMES 979 696-1787 Application number 07-00000516 000 000 Description of Work RESIDENTIAL, 1 UNIT DETACHED NEW Construction type . COMBUSTIBLE (UNPROTECTED) Occupancy type . . . . RESIDENTIAL-SFR/DUPLEX Flood Zone . . . . . . _ Approved . . . . . . . iV• - Bui ding Official VOID UNLESS SIGNED BY BUILDING OFFICIAL BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 -------------------------------------=------------------------------------- ' .. ..ter Application Number 07-00000516 Date 3/02/07 Property Address . . . . . . 5201 BALLYBUNION LN Property ID: 497900-0947-0110 R #: R Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . PEBBLE CREEK Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 293400 Owner Contractor ------------------------ ------------------------ MARIOTT HOMES 209 ROCK PRAIRIE RD COLLEGE STATION TX 77845 (979) 696-1787 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 3.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 3260.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 3.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC TAZ 419.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . NC Permit Fee . . . . 1042.00 Plan Check Fee .00 Issue Date . . . . 3/02/07 Valuation . . . . 293400 Expiration Date . . 8/29/07 Qty Unit Charge Per Extension BASE FEE 460.00 194.00 3.0000 THOU BLDG, VAL 100001-500000 582.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS OPENING (MINIMUM OUGH-FRAMED SIZE 2211 ------------------------------------------- BUILDING DEPT -----�-- --- ------------ REPRESENTATIVE: — l%/'-- An A - it APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 07-00000516 Page 2 Date 3/02/07 Special Notes and Comments X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8" side & 16" front) For Openings >6 sq. ft. (12" side & 20" front) ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12' ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, BUILDING DE APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 07-00000516 Page 3 Date 3/02/07 Special Notes and Comments STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. ------------------------------------------�-------I----- -------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 4 Application Number . . . . . 07-00000516 Date 3/02/07 ---------------------------------------------------------------------------- Special Notes and Comments WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK Be aware of right side of property is 7.5' PUE and setback. Narrow Wall Bracing Fully Sheathed with APA Framing, Interior anchors and bracing, and Engineered Panel per plans ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ---------------------------------------- ----------------- Permit Fee Total 1042.00 1042.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1792.00 1792.00 .-00 .00 --------------------- -----ld�------ ---,------------ BUILDING DEPT REPRESENTATIVE: z APPLICANT: TEMPORARY POLE PERMIT ` CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number 07-00000517 Date Property Address . . . . . . Property ID: R #• Application type description Subdivision Name Property Use . . . . . . . . Property Zoning . . . . . . . Application valuation 5201 BALLYBUNION LN 497900-0947-0110 R TEMP POLE PEBBLE CREEK RESIDENTIAL SINGLE FAMILY RESIDENTIAL 0 3/02/07 Owner Contractor ------------------------ ------------------------ MARIOTT HOMES 209 ROCK PRAIRIE RD COLLEGE STATION TX 77845 (979) 696-1787 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . NC Permit Fee . . . . 20.00 Issue Date . . . . 3/02/07 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited ------------------------------ Due ----------------- Permit Fee Total ---------- 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 --------------------------------------------------- • - ---------- BUILDING DEPT REPRESENTATIVE: APPLICANT: CITY OF COLLEGE STATION Planning d Development Service; APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX WWW.CSTX.GOV EorOHk seonly DATE• 1 RCC REG APPLICATION # :DRO TEMP POLE # V • I/ J `� ADDRESS/LOCATION: Y-,t4v t 0M11VV//l,1A6P7 Z-��' V— LOT BLOCK �-'SUBDIVISIONNTPP /(� Ig / SEC/PH- BUSINESS/OWNER NAME: . PHONE: 719 CONTRACTOR/HOMEOWNER:rj�ft-B,�%Jl��j ` PHONE: CONTRACTOR ADDRESS: ELECTRICIAN: HVAC: GOOD CENTS tRE CLASS OF WORK ACCESSORY/STORAGE LOCATION . RE -ROOF ADDITION M IN.G SHELL ONLY DEMOLITION (Asbestos Survey) EW CONSTRUCTION * SLAB ONLY DUPLEX (Landscape Plans REMODEL/RENOVATION* SWIMMING POOL Required) DESCRIPTION OF WORK: .STRUCTURE USE: HOMEOWNER ASSOC IATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ %/Q� ✓ TOTAL AREA: q,5,6:7 HEATED AREA: �O (Cost of Laborand Materials) UBLIC SEWER ❑ SEPTIC/TREATMENT SYSTEM VWER TAP: SIZE WATER TAP: 3/y SIZE OT ER TAP: SIZE TEMP POLE NUMBER OF BEDROOMS NUMBER OF BATHROOMS INTERIOR WALL TYPE EXTERIOR WALL TYPE FOUNDATION TYPE: ROOF TYPE: GARAGE TYPE: SINGLE � OUBLE a TRIPLE 1 ATTACHED �TACHED a CARPORT SIGNATURE OF APPLICANT: / *If proposed work involves new co Wmerclal construction or facade improveme v: o s ing commercial property, building elevations are required. Official *Use Only Z- Z 7 - o(o FIo : Plans Examiner ,a- 5(6* W AIE �� ► �y sLA4 a/l NA, Zoning Official Energy Code Compliance Information % Glazing of exterior walls o ✓ Insulation R value of exterior walls —. Insulation R value of ceiling 1 (flat areas) �Q� to. Insulation R value of. ceiling 2 ( vaulted areas/no attic ) q / Glazing SHGC Glazing U-Factor R ductwork / value of VC SEER Rating 1�� PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# O DATE: BUILDING ADDRESS: 5 � �I IV b uN1'ae% I. Foundation Requirements N lk A. Concrete minimum fc of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier Emil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior, unless over 60' long must be 30" 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated K II. Framing: Floor, Wall, Ceiling and Roof Requirements NA/ A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex JOK IffA 1. One -hour rated extending to roof deck MOK E. Header sizes indicated on plans NA/ K F. Emergency bedroom egress 1. Exit direct to outside 2. O enable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. O enable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing 2. Moisture barrier indicated on plans 3. Exterior Wall Covering J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size, spacing, roof slope & purlin bracing if required to reduces an O. Roof covering P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only S. All walls within 3' of property line to have protected openings. III. Stairway Requirements NA/OK A. Stairway Details NA/OK 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8 B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than twenty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements to be indicated onplans) NA/OK A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must meet IRC Chapter 10 Requirements V. Electrical Service Requirements A. Electrical plan to include: NA/OK 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX VI. Plumbing Requirements A. Pressure reducing valve required when water pressure exceeds 80 psi NA/OK B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements NA/OK A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) Vill. Energy Requirements NA/OK A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 NA/OK Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements NA/OK Maximum drive width for residence is 28' combined for circular Minimum 30 feet from driveway to side(intersecting) street Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 NA/OK Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 NA/OK Does not block any water course or divert any flow Elevation certificate needed "APPROVED PLANS PER IRC SECTION R106.3.1." PLANS EXAMINER DATE 35_ ql" -_71-3" AI I I �I I o l QQ I -{ 0 I I U I rl cl rl z rp► v_I rnl nl �I �I �I I �I DI i zl I rnl nl 7I .p ' ➢I rl w �I rnII 9 ZI I L rn PROPERTY LINE: C=13.72' B=N 36°20'015" W R-425.00' 2q"v7" 24' -5" LINE: 135.7q' - N 35°38'49" Jlj- )BLIC UTILITY EA MENT +att SUILUIN(m ZDG I MAC N LING J r� LINE: g1.00' - N 35°24'3q' W� CASCADES DRIVE v ol 51TE FLAN a �z Q � h' co m � I f To PROPERTY LINE, C=35.B7' B-N BI°15'04" W R=25.00' 26' -6" LOT, 11 BLOCK: 47 SUBDIVISION, PEBBLE CREEK PHASE q-D COLLEGE STATION, TX BRAZOS COUNTY