HomeMy WebLinkAboutRES2007-00463= I F PREPARED 7/27/07, 8:06:50 INSPECTION TICKET PAGE 7 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 7/26/07 ------------------------------------------------------------------------------------------------ ADDRESS . : 4113 WINDFREE DR SUBDIV: CONTRACTOR ED FROEHLING BUILDERS PHONE (979) 776-8266 OWNER ED FROEHLING BUILDER INC PHONE PARCEL 569500-1950-0060 APPL NUMBER: 07-00000463 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 4/09/07 OC BLDG, FOUNDATION -SLAB TIME: 17:00 4/09/07 AP April 9, 2007 12:02:40 PM glsouth. Strings On Setbacks O.K. Slab Ground Installed B115 01 5/15/07 OC BLDG, FRAMING TIME: 17:00 5/15/07 AP May 15, 2007 11:08:13 AM kwolfe. B130 01 5/24/07 RH BLDG, INSULATION TIME: 17:00 5/24/07 AP May 23, 2007 4:12:20 PM acarter. B125 01 7/ 6/07 BI-, BLDG, FINAL TIME: 17:00 July 26, 2007 3:49:19 PM acarter. ----=------------------- -------- CONTINUED ONTO NEXT PAGE ----------------------------------<<A - 91 WF0880157 / 001• City of -College Station ...� PAGE 1 REQ. DATE: 03/12/07 03/12/07 10:36:57 LOCATION: 4113 WINDFREE DR LOC ID: 204766 REQUESTOR: ED FROHLING BUILDERS ORIGIN: CUSTOMER -WALK IN REQ USER: KWOLFE AUTH USER:KWOLFE WRK TYPE: 4" SWR TAP 3/4" WTR TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 03/12/07 SCHED COMPLETION: 03/12/07 ******************************************************************************** JOB ORDER RESULT COMIENTS (7/30/2007) Gina Southerland Re: Calling for C TO @ 41131Nindfrue.Dr. From: Paul Schoenfeld To: Amber Carter; Benjamin McCarty; Chris Haver; Gina Southerland; Joe G... Date: 7/30/2007 12:20 PM Subject: 'Re: Calling for C.O. @ 4113 Windfree Dr. All ok. Paul >>> Gina Southerland 7/27/2007 8:20 AM >>> BP# 07-463 Gina Southerland CSR - Planning & Development Services City of College Station 979-764-3570 www.cstx.qov u.S.Ju1.31. 2007E_3_12PMsECUMCCIure_&_Browne Eng/Surveying, 'ATE Federal Emergency Management Agency - National Flood Insurance Program Important: Read the instructions on pages 1.8. NL�Lir'e�l�eb'ruarv'28_ 313 2009 Al. Building Owners Name SECTION A - PROPERTY INFORMATION dens, Inc. A2. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. 4113 Windfree Drive City College Station State TX ZIP Code77845 For Insurance Company Use: A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.) Lot 6, Block 50, Shenandoah, Phase 19 A4, Building Use (e.g., Residential, Non -Residential, Addition, Accessory, etc.) 'al A5. Latitude/Longitude: Lai 30.33 59 Long. %.16 17 Horizontal Datum: ❑ NAD 1927 0 NAD 1983 A6. Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance. A7. Building Diagram Numberl A8. For a building with a crawl space or enclosure(s), provide A9. For a building with an attached garage, provide: a) Square footage of crawl space or enclosures) sq ft a) Square footage of attached garage gq ft b) No. of permanent flood openings In the crawl space or b) N0. Of permanent flood openings in the attached garage enclosure(s) wells within 1.0 foot above adjacent grade walls within 1,0 (pot above adjacent grade C Total net area of flood openings in AB.b in c Total net area of flood oWings in A9.b so In Station SECTION B - FLOOD INSURANCE RATE MAP (FIRM) INFORMATION B2. Cc Brazos Texas 84. Map/Panel Number B5. Suffix B6. FIRM Index B7. FIRM Panel 88. Flood B9. Base Flood Elevation(s) (zone Date Effective/Revised Date Zone(s) AO, use base flood depth) 48041CO201 D 07/02/92 02/09/2000 Zone 283.0 810. Indicate the source of the Base Flood Elevation (BFE) data or base flood depth entered In hem 89. ❑ FIS Profile ❑ FIRM ® Community Determined ❑ Other (Describe) B11. Indicate elevation datum used for BFE in Item B9: ® NGVD 1929 ❑ NAVD 1988 ❑ Other (Describe) 812, Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? Oyes ®No Designation Date ❑ CBRS ❑ OPA SECTION C - BUILDING ELEVATION INFORMATION (SURVEY REQUIRED) Cl. Building elevations are based on: ❑ Construction Drawings' ❑ Building Under Construction* 0 Finished Construction 'A new Elevation Certificate will be raqulMd when construction of the building is complete. C2. Elevations —Zones Al-A30, AE, AH, A (with BFE), VE, VI-V30, V (with BFE), AR, AR/A, AR/AE, AR/A1-A30, AR/AH, AR/AO. Complete Items 02.a-g below according to the building diagram specified in Item A7, Benchmark Utilized Vertical Datum IgYL1929 Conversion/Comments See Comments a) Top of bottom floor (including basement, crawl space, or enciosure floor)_ b) Top of the next higher floor c) Bottom of the lowest horizontal structural member (V Zones only) d) Attached garage (top of slab) e) Lowest elevation of machinery or equipment servicing the building (Describe type of equipment in Comments) t) Lowest adjacent (finished) grade (LAG) g) Highest adjacent (finished) grade (HAG) Check the measurement used, 285.1 ® feet ❑ meters (Puerto Rico only) WA_ ❑ feet ❑ meters (Puerto Moo only) NIA d feet ❑ meters (Puerto Rico only) 285.1 ® feet ❑ meters (Puerto Rico only) jy(.e ❑ feet ❑ meters (Puerto Rico only) 24.2 0 feet ❑ meter; (Puerto Rico only) 234.3 ® feet ❑ meters (Puerto Rico only) SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation information. I certify that the Information on this CerdrWte represents my best efforts to interpret the data available. I understand that any false statement maybe punishable by fine or imprisonment under 18 U.S. Code. Section 1001. 0 t R Check hen: if comments are provided on back of form, Certifier's Name Kevin R. McClure License Number 565o Title Vice President - Surveying Company Name McClure & Browne Engineering/Surveying, Inc. Address 1008 Woodcreek Drive City College Station State TX ZIP Code 77845 ..�.............».,.......t,.... % 5 1� FEMA Form 81.31, February 2006 See reverse side for continuation. Replaces all previous editions iMpdul.31. 2001* 3:12P94y—tMcC1ure & Browne Eng/Surveying, No.3193---P. 2— _....—�—.. ,....,, - .ywVtl FL For insurance Company Use: Building Street Address (including Apt.. Unft, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number 4113 Windfree Drive City College Station StateTXZ1P Code 77845 Company NAIC Number SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION (CONTINUED) Copy both sides of this Elevation Certificate for (1) Community official, (2) insurance agent/Company, and (3) building owner. Comments BENCHMARK(; Chtseled square in S.W curbline of Windfree Dr, located 295.5' S.E, of the centerline of Southern Plantation Dr. Elevation = 283.18: THE ELEVATION SHOWN fN B.9 8 ON THE PLAT FOR THIS LOT IS A MINIMUM OF 1' ABOVE THE CALCULATED BASE FLOOD 8 REPRESENTS THE LOWEST HABITABLE FLOOR ELEV. FOR THE LOT AS REQUIRED BY CITY OF CIS $TORMWATER MGMT ORDINANCE. -, — SECTION E - BUILDING ELEVATION INFORMATION (SURVEY NOT REQUIRED) FOR ZONE AO AND ZONE A1C rn ent6 (IMTHOUT BFEFIE) For Zones AO and A (without BFE), complete Items E1-E5. If the Certificate is intended to support a LOMA or LOMR-F request, complete Sections A, B, and C. For Items EJ-E4, use natural grade, if available. Check the measurement used_ In Puerto Rloo only, enter meters. Et. Provide elevation Information for the following and check the appropriate boxes to show whether the elevation Is above or below the highest adjacent grade (HAG) and the lowest adjacent grade (LAG), a) Top of bottom floor (including basement, crawl space, or enclosure is ❑ feet ❑ meters ❑ above or ❑ below the HAG. b) Top of bottom floor (including basement crawl space or enclosure) is ❑feet El Meters ❑above or ❑ below the LAG. E2. For Building Diagrams 6-8 with permanent flood openings provided In Section A hems 8 and/or 9 (set age 8 of Instructions), the next higher floor (elevation C2-b in the diagrams) of the building is ❑ feet ❑ meters [I above or Ipbelow the HAG. E3. Attached garage (top of slab) is ❑ feet ❑ meters ❑ above or ❑ below the HAG, 84. Top of platform of machinery and/or equipment servicing the building is ❑ feet ❑ meters E5. Zone AO only: If no flood depth number is available, i5 the top of the bottom floor elevated in accordance � the above or below the llai mane ordinance? P Bement ❑ Yes ❑ No ❑Unknown, The focal official must certify this information in Section G. SECTION F - PROPERTY OWNER (OR OWNER'S REPRESENTATIVE) CERTIFICATION The property owner or owner's authorized representative who completes Sections A, B, and E for Zone A (without a FEMA-issued or community -issued BFE) or Zone AO must sign here. The statements in Sections A, B, and E are correct to the beat of my knowledge. Property Owner's or Owner's Authorized Representative's Name Address City State ZIP Code Signature Date Telephone Comments Ch here If achments SECTION G - COMMUNITY INFORMATION (OPTIONAL) The local official who is authorized by law or ordinance to administer the community's floodplain management ordinance Can complete Sections A, B, C (or E), and G of this Elevation Certificate, Complete the applicable item(s) and sign below. Check the measurement used in hems G8. and G9. G1. ❑ The information in Section C was taken from other documentation that has been signed and heeled by a licensed surveyor, engineer, or architect who is authorized by law to Certify elevation information. (Indicate the source and date of the elevation data in the Comments area below.) G2. [] A community official Completed Section E for a building located in Zone A (without a FEMA-issued of Community -Issued BFE) or Zone AO. G3. ❑ The following information (Items G4= G9.) is provided for community floodplain management purposes, G4. Permit Number Date Permit Issued Data Certificate Of ComplianceJOccupancy GT This permit has been Issued for; ❑ New Construction ❑ Substantial Improvement G8. Elevation of as -built lowest floor (including basement) of the building: _❑ feet ❑ meters (PR) Datum G9. BFE or (in Zone AO) depth of flooding at the building Site: ❑ feet ❑ meters (PR) Datum Local Official's Name T410 Community Name Telephone Signature Comments Date ❑ �Ck here if attachments FEMA Farm 81-31, February 2006 Replaces all previous editions U.S. DEPARTMENT OF HOMELAND SECURITY Federal Emergency Management Agency National Flood Insurance Program ELEVATION CERTIFICATE Important: Read the instructions on pages 1-8. OMB No. 1660-0008 Expires February 28. 2009 SECTION A - PROPERTY INFORMATION I For Insurance Company Use: Al. Building Owner's Name Edward Froehling Builders, Inc. Policy Number A2. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. I Company NAIC Number I 4113 Windfree Drive City College Station State TX ZIP Code77845 A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.) Lot 6, Block 50, Shenandoah, Phase 19 A4. Building Use (e.g., Residential, Non -Residential, Addition, Accessory, etc.) Residential A5. Latitude/Longitude: Lat. 30.33 59 Long. -96.16 17 Horizontal Datum: ® NAD 1927 ❑ NAD 1983 A6. Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance. A7. Building Diagram Numberl A8. For a building with a crawl space or enclosure(s), provide A9. For a building with an attached garage, provide: a) Square footage of crawl space or enclosure(s) sq ft a) Square footage of attached garage sq ft b) No. of permanent flood openings in the crawl space or b) No. of permanent flood openings in the attached garage enclosure(s) walls within 1.0 foot above adjacent grade walls within 1.0 foot above adjacent grade c) Total net area of flood openings in A8.b sq in c) Total net area of flood openings in A9.b sq in SECTION B - FLOOD INSURANCE RATE MAP (FIRM) INFORMATION B1. NFIP Community Name & Community Number B2. County Name B3. State College Station 480083 1 Brazos Texas 7 B4. Map/Panel Number B5. Suffix B6. FIRM Index B7. FIRM Panel B8. Flood B9. Base Flood Elevation(s) (Zone Date Effective/Revised Date Zone(s) AO, use base flood depth) 48041 CO201 D 07/02/92 02/09/2000 Zone X 283.0 B10. Indicate the source of the Base Flood Elevation (BFE) data or base flood depth entered in Item B9. ❑ FIS Profile ❑ FIRM ® Community Determined ❑ Other (Describe) _ B11. Indicate elevation datum used for BFE in Item 69: ® NGVD 1929 ❑ NAVD 1988 ❑ Other (Describe) B12. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? ❑Yes ®No Designation Date ❑ CBRS ❑ OPA SECTION C - BUILDING ELEVATION INFORMATION (SURVEY REQUIRED) Cl. Building elevations are based on: ❑ Construction Drawings* ® Building Under Construction* ❑ Finished Construction *A new Elevation Certificate will be required when construction of the building is complete. C2. Elevations -Zones Ai-A30, AE, AH, A (with BFE), VE, V1-V30, V (with BFE), AR, AR/A, AR/AE, AR/A1-A30, AR/AH, AR/AO. Complete Items C2.a-g below according to the building diagram specified in Item A7. Benchmark Utilized Vertical Datum NGVD 1929 Conversion/Comments See Comments a) Top of bottom floor (including basement, crawl space, or enclosure floor)_ b) Top of the next higher floor c) Bottom of the lowest horizontal structural member (V Zones only) d) Attached garage (top of slab) e) Lowest elevation of machinery or equipment servicing the building (Describe type of equipment in Comments) 0 Lowest adjacent (finished) grade (LAG) g) Highest adjacent (finished) grade (HAG) Check the measurement used. 285.1 ® feet ❑ meters (Puerto Rico only) N/.A ❑ feet ❑ meters (Puerto Rico only) N/.A ❑ feet ❑ meters (Puerto Rico only) 285.1 ® feet ❑ meters (Puerto Rico only) N/.A ❑ feet ❑ meters (Puerto Rico only) 283.4 ® feet ❑ meters (Puerto Rico only) 284.0 ® feet ❑ meters (Puerto Rico only) SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation information. I certify that the information on this Certificate represents my best efforts to interpret the data available. I understand that any false statement may be punishable by fine or imprisonment under 18 U.S. Code, Section 1001. ® Check here if comments are provided on back of form. Certifier's Name Kevin R. McClure License Number 5650 Title Vice President - Surveying Company Name McClure & Browne Engineering/Surveying, Inc. Address 1008 Woodcreek Drive City College Station State TX ZIP Code 77845 Signature y Date 03/21/2007 Telephone (979) 693-3838 FEMA Form 81-31, February 2006 See reverse side for continuation. Replaces all previous editions IMPORTANT: In these spaces, copy the corresponding information from Section A. For Insurance Company Use: Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number 4113 Windfree Drive City College Station StateTXZIP Code 77845 Company NAIC Number SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION (CONTINUED) Copy both sides of this Elevation Certificate for (1) community official, (2) insurance agent/company, and (3) building owner. Comments BENCHMARK: Chiseled square in S.W curbline of Windfree Dr. located 295.5' S.E. of the centerline of Southern Plantation Dr. Elevation = 283.18; THE ELEVATION SHOWN IN B.9 & ON THE PLAT FOR THIS LOT IS A MINIMUM OF 1' ABOVE THE CALCULATED BASE FLOOD & REPRESENTS THE LOWEST HABITABLE FLOOR ELEV. FOR THE LOT AS REQUIRED BY CITY OF C/S STORMWATER MGMT ORDINANCE Signature <r Ac/�� uate usrzitzuui ❑Check here if attachments SECTION E - BUILDINd ELEVATION INFORMATION (SURVEY NOT REQUIRED) FOR ZONE AO AND ZONE A (WITHOUT BFE) For Zones AO and A (without BFE), complete Items El-E5. If the Certificate is intended to support a LOMA or LOMR-F request, complete Sections A, B, and C. For Items El-E4, use natural grade, if available. Check the measurement used. In Puerto Rico only, enter meters. E1. Provide elevation information for the following and check the appropriate boxes to show whether the elevation is above or below the highest adjacent grade (HAG) and the lowest adjacent grade (LAG). a) Top of bottom floor (including basement, crawl space, or enclosure) is ❑ feet ❑ meters ❑ above or ❑ below the HAG. b) Top of bottom floor (including basement, crawl space, or enclosure) is ❑ feet ❑ meters ❑ above or ❑ below the LAG. E2. For Building Diagrams 6-8 with permanent flood openings provided in Section A Items 8 and/or 9 (see page 8 of Instructions), the next higher floor (elevation C2.b in the diagrams) of the building is ❑ feet ❑ meters ❑ above or ❑ below the HAG. E3. Attached garage (top of slab) is ❑ feet ❑ meters ❑ above or ❑ below the HAG. E4. Top of platform of machinery and/or equipment servicing the building is ❑ feet ❑ meters ❑ above or ❑ below the HAG. E5. Zone AO only: If no flood depth number is available, is the top of the bottom floor elevated in accordance with the community's floodplain management ordinance? ❑ Yes ❑ No ❑ Unknown. The local official must certify this information in Section G. SECTION F - PROPERTY OWNER (OR OWNER'S REPRESENTATIVE) CERTIFICATION The property owner or owner's authorized representative who completes Sections A, B, and E for Zone A (without a FEMA-issued or community -issued BFE) or Zone AO must sign here. The statements in Sections A, B, and E are correct to the best of my knowledge. Property Owner's or Owner's Authorized Representative's Name Address City State ZIP Code Signature Date Telephone Comments ❑ Check here if attachments SECTION G - COMMUNITY INFORMATION (OPTIONAL) The local official who is authorized by law or ordinance to administer the community's floodplain management ordinance can complete Sections A, B, C (or E), and G of this Elevation Certificate. Complete the applicable item(s) and sign below. Check the measurement used in Items G8. and G9. G1. ❑ The information in Section C was taken from other documentation that has been signed and sealed by a licensed surveyor, engineer, or architect who is authorized by law to certify elevation information. (Indicate the source and date of the elevation data in the Comments area below.) G2. ❑ A community official completed Section E for a building located in Zone A (without a FEMA-issued or community -issued BFE) or Zone AO. G3. ❑ The following information (Items G4.-G9.) is provided for community floodplain management purposes. G4. Permit Number G5. Date Permit Issued G6. Date Certificate Of Compliance/Occupancy Issued G7. This permit has been issued for: ❑ New Construction ❑ Substantial Improvement G8. Elevation of as -built lowest floor (including basement) of the building: ❑ feet ❑ meters (PR) Datum G9. BFE or (in Zone AO) depth of flooding at the building site: ❑ feet ❑ meters (PR) Datum Local Official's Name Title Community Name Telephone Signature Date Comments Check here if attachments FEMA Form 81-31, February 2006 Replaces all previous editions BUILDING PERMIT CITY OF C"rY�E STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 07-00000463 Date 3/08/07 Property Address . . . . . . 4113 WINDFREE DR Property ID: 569500-1950-0060 R #: R304151 Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 140646 Owner Contractor ------------------------ ------------------------ ED FROEHLING BUILDER INC ED FROEHLING BUILDERS 3887 HIGH LONESOME 3887 HIGH LONESOME RD COLLEGE STATION TX 778459443 COLLEGE STATION TX 77845 (979) 776-8266 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID YES FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 2131.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC TAZ 422.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc KW Permit Fee . . . . 583.00 Plan Check Fee .00 Issue Date . . . . 3/08/07 Valuation . . . . 140646 Expiration Date . . 9/04/07 Qty Unit Charge Per Extension BASE FEE 460.00 41.00 3.0000 THOU BLDG, VAL 100001-500000 123.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" �REPR ------ -((��--s---------- ------ -- -- ------------ BUILDING D Z4T.ATIV��I P APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979).764-3496 Application Number 07-00000463 Page 2 Date 3/08/07 Special Notes and Comments X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELEVATION CERTIFICATE REQUIRED - PROVIDE ELEVATION CERTIFICATE PRIOR TO SLAB INSPECTION AND A SECOND CERTIFICATE PRIOR TO FINAL INSPECTION/C.O. Minimum Finished Floor is 283.0' ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8" side & 16" front) For Openings >6 sq. ft. (12" side & 20" front) ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPR BUILDING APPLICANT BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 3 Application Number . . . . . 07-00000463 Date 3/08/07 ---------------------------------------------------------------------------- Special Notes and Comments TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12' ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN.CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED - --- ---, 0 VOLT W/BATTERY --------------------------- - -- ------------ BUILDING DEPT REPRESENTATIVE: /�! - APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 4 Application Number . . . . . 07-00000463 Date 3/08/07 ---------------------------------------------------------------------------- Special Notes and Comments BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND CLOTHES DRYERS. Narrow Wall Bracing Fully Sheathed with APA Garage Framing ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ------------------------------ --------------------------- Permit Fee Total 583.00 583.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1333.00 1333.00 .00 .00 BUILDING L APPLICANT: APPLICATION FOR BUILDING PERMIT 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX CITY OF COLLEGE STATION WWW.CSTX.GOV Planning d Dcvtldpment Sriviai DATE: TRCC REG APPLICATION # TEMP POLE # W, AD OCATION: NV kJ KIVIII!-- LOT BLOCK 1% — SUBDIVISION SEC/PH�_-� EM"BUSIlkM WNER NAME: PHONE: CONT R/HOMEOWNER: Fit) �Rosau !4 PHONE: 7d7!o' 113Z1i(0 rn ON T ' RADDRESS: 3eb% 14ICyLoOugpME Ro• GSTX 771945- 0 LE '� PLUMBER: HVAC: GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION - MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ON DUPLEX (Landscape Plans) REMODEL/RENOVATION* SWIMMING F ` J. t)�� -''—�DESCRIPTION OF WORK: �r1 PROPOSED USE: q\v HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPPRJ VALUATION: $ TOTAL AREA: Z (0(0D HEATED AREA: Z I3 (Cost of Lat;.,-d`nd Materials) U r UBLIC SEWER ❑ SEPTIC/TREATMENT SYSTEM u R SEWER TAP: ,E 11 WATER TAP: ij SIZE ❑ OTHER TAP: NUMBER OF BEDROOMS: 4 NUMBER OF BATHROOMS: 2 INTERIOR WALL TYPE: 514�"ROCIL EXTERIOR WALL TYPE: I Ater. FOUNDATION TYPE: SLAS 04 Q��tWf SIZE EMP POLE ROOF TYPE: �M F' tri GARAGE TYPE: SINGLE F] DOUBLE [je TRIPLE ATTACHED [2r DETACHED CARPORT ;;�-�Am SIGNATURE OF APPLICANT: A (0".A *If proposed work involves new co'frPmerod Mjtr-uctitqfc. e i prove s/renovations to an existing commercial property, building elevations arTireq&'4.e�� l Official Use Only jT-,:,16 —o'7 Plans Examiner Zoning Official /Z23 fAiw • FF . / 84- V&41(ow Comments: GAO-41lt W1 P Q NO Q (y S-tj%.� (4,Jllpe Fire Marshall 0.1 Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls 3 Insulation R value of ceiling 1 (flat areas) 30 Insulation R value of ceiling 2 (vaulted areas/no attic) 1 tv-, Glazing SHGC ° AC) / Glazing U-Factor R value of ductwork �P A/C SEER Rating V reo. I4. [dui [:3urm wcliure a Browne cng; aurveying, No. ZOO r. I/I .Q/ b W I G'QIX�M.i}�t` E %l°.f7v9 IMIAS dW Lot 06 Took DO.dwg l 1 NOW grq W.foeL� �- Yd.7In 343. . Now or F� T J 44$6,j8 20' F.U.E. r _ �--_ • _ 29.r (� S.L.) 3 I I `'•0' � 1 y 7.8' ' Zot d BlooJr 50 N I I shonondooh Rho" to qw I or r r r Windfiee Qn've 50' R.aW. M 27' POwmmt W .. 73AX Pg. 101 Scale: 1" - 2D' CURVE m&CL \ CURVE DELTA RADIUS LPNCTH CHORD. Oft C1 ♦ 60'12` KW 40.00' N 16.25'03' Y1W bP � �1 PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# 07 _ / DATE: BUILDING ADDRESS: - q1 13 Ih I. Foundation Requirements N A. Concrete minimum f'c of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier Emil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior, unless over 60' long must be 30" 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated K II. Framing: Floor, Wall, Ceiling and Roof Requirements N A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex OK 1. One -hour rated extending to roof deck K E. Header sizes indicated on plans NA(OK) F. Emergency bedroom egress 1. Exit direct to outside 2. O enable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. O enable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing 2. Moisture barrier indicated on plans 3. Exterior Wall Covering J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size, spacing, roof slope & purlin bracing if required to reduces an O. Roof covering P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only S. All walls within 3' of property line to have protected openings. III. Stairway Requirements OK A. Stairway Details (NAJOK 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8 B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than twenty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements to be indicated onplans)N A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must meet IRC Chapter 10 Requirements V. Electrical Service Requirements A. Electrical plan to include: NAT9 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location b PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX VI. Plumbing Requirements A. Pressure reducing valve required when water pressure exceeds 80 psi N O B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements NA/ A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) VIII. Energy Requirements N K A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 NAtW Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements NA/ Maximum drive width for residence is 28' combined for circular Minimum 30 feet from driveway to side(intersecting) street Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 N Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 NA/ Does not block any water course or divert any flow Elevation certificate needed 2 O "APPROVED PLANS PER IRC SECTION R106.3.1." "14 ?- -016-0 ; "—PLANS EXAMINER DATE Permit Number REScheck Compliance Certificate Checked By/Date 2000 IECC REScheckSoftware Version 3.5 Release lb Data filename: C:\Program Files\Check\REScheck\4113WF.rck TITLE: 4113 WINDFREE DRIVE CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 02/22/07 DATE OF PLANS: NOVEMBER 1, 2002 PROJECT INFORMATION: HOME FOR MARTINEZ LOT 6 BLOCK 50, SHENANDOAH PHASE 19 COMPANY INFORMATION: ED FROEHLING BUILDER, INC NOTES: ORIGINALLY 1208 SB (LEMKE PLAN) COMPLIANCE: Passes Maximum UA = 700 Your Home UA = 570 18.6% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.36 Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1: Flat Ceiling or Scissor Truss 2131 30.0 0.0 75 Wall 1: Wood Frame, 16" o.c. 430 15.0 0.0 26 Window 1: Metal Frame:Double Pane with Low-E 60 0.640 38 SHGC: 0.40 Bldg. faces 270 deg. from North; Comp. orient.: Front Projection factor: 0.18 Door 1: Solid 38 0.800 30 Wall 2: Wood Frame, 16" o.c. 490 15.0 0.0 33 Window 2: Metal Frame:Double Pane with Low-E 66 0.640 42 SHGC: 0.40 Bldg. faces 270 deg. from North; Comp. orient.: Left Side Projection factor: 0.18 Wall 3: Wood Frame, 16" o.c. 403 15.0 0.0 24 Window 3: Metal Frame:Double Pane with Low-E 72 0.640 46 t Jr 'or, .. SHGC: 0.40 Bldg. faces 270 deg. from North; Comp. orient.: Back Projection factor: 0.27 Door 2: Glass 18 0.580 10 SHGC: 0.78 Bldg. faces 270 deg. from North; Comp. orient.: Back Projection factor: 0.81 Wall 4: Wood Frame, 16" o.c. 398 15.0 0.0 29 Window 4: Metal Frame:Double Pane with Low-E 27 0.640 17 SHGC: 0.40 Bldg. faces 270 deg. from North; Comp. orient.: Right Side Projection factor: 0.27 Floor 1: Slab-On-Grade:Unheated 192 0.0 200 Insulation depth: 0.0' Air Conditioner 1: Electric Central Air, 13 SEER COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in RESche sion 3.5 Releas lb (f erly MECch and to comply with t e mandato requirements listed in the RES checkI ction Chec t. $1 f4 W I Builder esigner Date ��