HomeMy WebLinkAboutRES2007-00463= I
F
PREPARED 7/27/07, 8:06:50 INSPECTION TICKET PAGE 7
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 7/26/07
------------------------------------------------------------------------------------------------
ADDRESS . : 4113 WINDFREE DR SUBDIV:
CONTRACTOR ED FROEHLING BUILDERS PHONE (979) 776-8266
OWNER ED FROEHLING BUILDER INC PHONE
PARCEL 569500-1950-0060
APPL NUMBER: 07-00000463 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 4/09/07 OC BLDG, FOUNDATION -SLAB TIME: 17:00
4/09/07 AP April 9, 2007 12:02:40 PM glsouth.
Strings On Setbacks O.K.
Slab Ground Installed
B115 01 5/15/07 OC BLDG, FRAMING TIME: 17:00
5/15/07 AP May 15, 2007 11:08:13 AM kwolfe.
B130 01 5/24/07 RH BLDG, INSULATION TIME: 17:00
5/24/07 AP May 23, 2007 4:12:20 PM acarter.
B125 01 7/ 6/07 BI-, BLDG, FINAL TIME: 17:00
July 26, 2007 3:49:19 PM acarter.
----=------------------- -------- CONTINUED ONTO NEXT PAGE ----------------------------------<<A
-
91
WF0880157 / 001• City of -College Station
...�
PAGE 1
REQ. DATE: 03/12/07 03/12/07 10:36:57
LOCATION: 4113 WINDFREE DR LOC ID: 204766
REQUESTOR: ED FROHLING BUILDERS ORIGIN: CUSTOMER -WALK IN
REQ USER: KWOLFE AUTH USER:KWOLFE WRK TYPE:
4" SWR TAP 3/4" WTR TAP
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 03/12/07 SCHED COMPLETION: 03/12/07
********************************************************************************
JOB ORDER RESULT COMIENTS
(7/30/2007) Gina Southerland Re: Calling for C TO @ 41131Nindfrue.Dr.
From: Paul Schoenfeld
To: Amber Carter; Benjamin McCarty; Chris Haver; Gina Southerland; Joe G...
Date: 7/30/2007 12:20 PM
Subject: 'Re: Calling for C.O. @ 4113 Windfree Dr.
All ok.
Paul
>>> Gina Southerland 7/27/2007 8:20 AM >>>
BP# 07-463
Gina Southerland
CSR - Planning & Development Services
City of College Station
979-764-3570
www.cstx.qov
u.S.Ju1.31. 2007E_3_12PMsECUMCCIure_&_Browne Eng/Surveying, 'ATE
Federal Emergency Management Agency -
National Flood Insurance Program Important: Read the instructions on pages 1.8.
NL�Lir'e�l�eb'ruarv'28_
313
2009
Al. Building Owners Name
SECTION A - PROPERTY INFORMATION
dens, Inc.
A2. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No.
4113 Windfree Drive
City College Station State TX ZIP Code77845
For Insurance Company Use:
A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.)
Lot 6, Block 50, Shenandoah, Phase 19
A4, Building Use (e.g., Residential, Non -Residential, Addition, Accessory, etc.) 'al
A5. Latitude/Longitude: Lai 30.33 59 Long. %.16 17 Horizontal Datum: ❑ NAD 1927 0 NAD 1983
A6. Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance.
A7. Building Diagram Numberl
A8. For a building with a crawl space or enclosure(s), provide A9. For a building with an attached garage, provide:
a) Square footage of crawl space or enclosures) sq ft a) Square footage of attached garage gq ft
b) No. of permanent flood openings In the crawl space or b) N0. Of permanent flood openings in the attached garage
enclosure(s) wells within 1.0 foot above adjacent grade walls within 1,0 (pot above adjacent grade
C Total net area of flood openings in AB.b in c Total net area of flood oWings in A9.b so In
Station
SECTION B - FLOOD INSURANCE RATE MAP (FIRM) INFORMATION
B2. Cc
Brazos
Texas
84. Map/Panel Number B5. Suffix B6. FIRM Index B7. FIRM Panel 88. Flood B9. Base Flood Elevation(s) (zone
Date Effective/Revised Date Zone(s) AO, use base flood depth)
48041CO201 D 07/02/92 02/09/2000 Zone 283.0
810. Indicate the source of the Base Flood Elevation (BFE) data or base flood depth entered In hem 89.
❑ FIS Profile ❑ FIRM ® Community Determined ❑ Other (Describe)
B11. Indicate elevation datum used for BFE in Item B9: ® NGVD 1929 ❑ NAVD 1988 ❑ Other (Describe)
812, Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? Oyes ®No
Designation Date ❑ CBRS ❑ OPA
SECTION C - BUILDING ELEVATION INFORMATION (SURVEY REQUIRED)
Cl. Building elevations are based on: ❑ Construction Drawings' ❑ Building Under Construction* 0 Finished Construction
'A new Elevation Certificate will be raqulMd when construction of the building is complete.
C2. Elevations —Zones Al-A30, AE, AH, A (with BFE), VE, VI-V30, V (with BFE), AR, AR/A, AR/AE, AR/A1-A30, AR/AH, AR/AO. Complete Items 02.a-g
below according to the building diagram specified in Item A7,
Benchmark Utilized Vertical Datum IgYL1929
Conversion/Comments See Comments
a) Top of bottom floor (including basement, crawl space, or enciosure floor)_
b) Top of the next higher floor
c) Bottom of the lowest horizontal structural member (V Zones only)
d) Attached garage (top of slab)
e) Lowest elevation of machinery or equipment servicing the building
(Describe type of equipment in Comments)
t) Lowest adjacent (finished) grade (LAG)
g) Highest adjacent (finished) grade (HAG)
Check the measurement used,
285.1
® feet ❑ meters (Puerto Rico only)
WA_
❑ feet ❑ meters (Puerto Moo only)
NIA
d feet ❑ meters (Puerto Rico only)
285.1
® feet ❑ meters (Puerto Rico only)
jy(.e
❑ feet ❑ meters (Puerto Rico only)
24.2
0 feet ❑ meter; (Puerto Rico only)
234.3
® feet ❑ meters (Puerto Rico only)
SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION
This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation
information. I certify that the Information on this CerdrWte represents my best efforts to interpret the data available.
I understand that any false statement maybe punishable by fine or imprisonment under 18 U.S. Code. Section 1001. 0 t
R Check hen: if comments are provided on back of form,
Certifier's Name Kevin R. McClure License Number 565o
Title Vice President - Surveying Company Name McClure & Browne Engineering/Surveying, Inc.
Address 1008 Woodcreek Drive City College Station State TX ZIP Code 77845
..�.............».,.......t,....
% 5 1�
FEMA Form 81.31, February 2006 See reverse side for continuation. Replaces all previous editions
iMpdul.31. 2001* 3:12P94y—tMcC1ure & Browne Eng/Surveying, No.3193---P. 2—
_....—�—.. ,....,, - .ywVtl FL For insurance Company Use:
Building Street Address (including Apt.. Unft, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number
4113 Windfree Drive
City College Station StateTXZ1P Code 77845 Company NAIC Number
SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION (CONTINUED)
Copy both sides of this Elevation Certificate for (1) Community official, (2) insurance agent/Company, and (3) building owner.
Comments BENCHMARK(; Chtseled square in S.W curbline of Windfree Dr, located 295.5' S.E, of the centerline of Southern Plantation Dr.
Elevation = 283.18: THE ELEVATION SHOWN fN B.9 8 ON THE PLAT FOR THIS LOT IS A MINIMUM OF 1' ABOVE THE CALCULATED BASE FLOOD
8 REPRESENTS THE LOWEST HABITABLE FLOOR ELEV. FOR THE LOT AS REQUIRED BY CITY OF CIS $TORMWATER MGMT ORDINANCE.
-, —
SECTION E - BUILDING ELEVATION INFORMATION (SURVEY NOT REQUIRED) FOR ZONE AO AND ZONE A1C rn ent6
(IMTHOUT BFEFIE)
For Zones AO and A (without BFE), complete Items E1-E5. If the Certificate is intended to support a LOMA or LOMR-F request, complete Sections A, B,
and C. For Items EJ-E4, use natural grade, if available. Check the measurement used_ In Puerto Rloo only, enter meters.
Et. Provide elevation Information for the following and check the appropriate boxes to show whether the elevation Is above or below the highest adjacent
grade (HAG) and the lowest adjacent grade (LAG),
a) Top of bottom floor (including basement, crawl space, or enclosure is
❑ feet ❑ meters ❑ above or ❑ below the HAG.
b) Top of bottom floor (including basement crawl space or enclosure) is ❑feet El Meters ❑above or ❑ below the LAG.
E2. For Building Diagrams 6-8 with permanent flood openings provided In Section A hems 8 and/or 9 (set age 8 of Instructions), the next higher floor
(elevation C2-b in the diagrams) of the building is ❑ feet ❑ meters [I above or Ipbelow the HAG.
E3. Attached garage (top of slab) is ❑ feet ❑ meters ❑ above or ❑ below the HAG,
84. Top of platform of machinery and/or equipment servicing the building is ❑ feet ❑ meters
E5. Zone AO only: If no flood depth number is available, i5 the top of the bottom floor elevated in accordance � the above or below the llai mane ordinance? P Bement
❑ Yes ❑ No ❑Unknown, The focal official must certify this information in Section G.
SECTION F - PROPERTY OWNER (OR OWNER'S REPRESENTATIVE) CERTIFICATION
The property owner or owner's authorized representative who completes Sections A, B, and E for Zone A (without a FEMA-issued or community -issued BFE)
or Zone AO must sign here. The statements in Sections A, B, and E are correct to the beat of my knowledge.
Property Owner's or Owner's Authorized Representative's Name
Address City State ZIP Code
Signature Date
Telephone
Comments
Ch here If achments
SECTION G - COMMUNITY INFORMATION (OPTIONAL)
The local official who is authorized by law or ordinance to administer the community's floodplain management ordinance Can complete Sections A, B, C (or E),
and G of this Elevation Certificate, Complete the applicable item(s) and sign below. Check the measurement used in hems G8. and G9.
G1. ❑ The information in Section C was taken from other documentation that has been signed and heeled by a licensed surveyor, engineer, or architect who
is authorized by law to Certify elevation information. (Indicate the source and date of the elevation data in the Comments area below.)
G2. [] A community official Completed Section E for a building located in Zone A (without a FEMA-issued of Community -Issued BFE) or Zone AO.
G3. ❑ The following information (Items G4= G9.) is provided for community floodplain management purposes,
G4. Permit Number
Date Permit Issued
Data Certificate Of ComplianceJOccupancy
GT This permit has been Issued for; ❑ New Construction ❑ Substantial Improvement
G8. Elevation of as -built lowest floor (including basement) of the building: _❑ feet ❑ meters (PR) Datum
G9. BFE or (in Zone AO) depth of flooding at the building Site: ❑ feet ❑ meters (PR) Datum
Local Official's Name T410
Community Name Telephone
Signature
Comments
Date
❑ �Ck here if attachments
FEMA Farm 81-31, February 2006 Replaces all previous editions
U.S. DEPARTMENT OF HOMELAND SECURITY
Federal Emergency Management Agency
National Flood Insurance Program
ELEVATION CERTIFICATE
Important: Read the instructions on pages 1-8.
OMB No. 1660-0008
Expires February 28. 2009
SECTION A - PROPERTY INFORMATION I For Insurance Company Use:
Al. Building Owner's Name Edward Froehling Builders, Inc. Policy Number
A2. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. I Company NAIC Number I
4113 Windfree Drive
City College Station State TX ZIP Code77845
A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.)
Lot 6, Block 50, Shenandoah, Phase 19
A4. Building Use (e.g., Residential, Non -Residential, Addition, Accessory, etc.) Residential
A5. Latitude/Longitude: Lat. 30.33 59 Long. -96.16 17 Horizontal Datum: ® NAD 1927 ❑ NAD 1983
A6. Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance.
A7. Building Diagram Numberl
A8. For a building with a crawl space or enclosure(s), provide A9. For a building with an attached garage, provide:
a) Square footage of crawl space or enclosure(s) sq ft a) Square footage of attached garage sq ft
b) No. of permanent flood openings in the crawl space or b) No. of permanent flood openings in the attached garage
enclosure(s) walls within 1.0 foot above adjacent grade walls within 1.0 foot above adjacent grade
c) Total net area of flood openings in A8.b sq in c) Total net area of flood openings in A9.b sq in
SECTION B - FLOOD INSURANCE RATE MAP (FIRM) INFORMATION
B1. NFIP Community Name & Community Number B2. County Name B3. State
College Station 480083 1 Brazos Texas 7
B4. Map/Panel Number
B5. Suffix
B6. FIRM Index
B7. FIRM Panel
B8. Flood
B9. Base Flood Elevation(s) (Zone
Date
Effective/Revised Date
Zone(s)
AO, use base flood depth)
48041 CO201
D
07/02/92
02/09/2000
Zone X
283.0
B10. Indicate the source of the Base Flood Elevation (BFE) data or base flood depth entered in Item B9.
❑ FIS Profile ❑ FIRM ® Community Determined ❑ Other (Describe) _
B11. Indicate elevation datum used for BFE in Item 69: ® NGVD 1929 ❑ NAVD 1988 ❑ Other (Describe)
B12. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? ❑Yes ®No
Designation Date ❑ CBRS ❑ OPA
SECTION C - BUILDING ELEVATION INFORMATION (SURVEY REQUIRED)
Cl. Building elevations are based on: ❑ Construction Drawings* ® Building Under Construction* ❑ Finished Construction
*A new Elevation Certificate will be required when construction of the building is complete.
C2. Elevations -Zones Ai-A30, AE, AH, A (with BFE), VE, V1-V30, V (with BFE), AR, AR/A, AR/AE, AR/A1-A30, AR/AH, AR/AO. Complete Items C2.a-g
below according to the building diagram specified in Item A7.
Benchmark Utilized Vertical Datum NGVD 1929
Conversion/Comments See Comments
a) Top of bottom floor (including basement, crawl space, or enclosure floor)_
b) Top of the next higher floor
c) Bottom of the lowest horizontal structural member (V Zones only)
d) Attached garage (top of slab)
e) Lowest elevation of machinery or equipment servicing the building
(Describe type of equipment in Comments)
0 Lowest adjacent (finished) grade (LAG)
g) Highest adjacent (finished) grade (HAG)
Check the measurement used.
285.1
® feet
❑ meters (Puerto Rico only)
N/.A
❑ feet
❑ meters (Puerto Rico only)
N/.A
❑ feet
❑ meters (Puerto Rico only)
285.1
® feet
❑ meters (Puerto Rico only)
N/.A
❑ feet
❑ meters (Puerto Rico only)
283.4
® feet
❑ meters (Puerto Rico only)
284.0
® feet
❑ meters (Puerto Rico only)
SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION
This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation
information. I certify that the information on this Certificate represents my best efforts to interpret the data available.
I understand that any false statement may be punishable by fine or imprisonment under 18 U.S. Code, Section 1001.
® Check here if comments are provided on back of form.
Certifier's Name Kevin R. McClure License Number 5650
Title Vice President - Surveying Company Name McClure & Browne Engineering/Surveying, Inc.
Address 1008 Woodcreek Drive City College Station State TX ZIP Code 77845
Signature y Date 03/21/2007 Telephone (979) 693-3838
FEMA Form 81-31, February 2006
See reverse side for continuation.
Replaces all previous editions
IMPORTANT: In these spaces, copy the corresponding information from Section A. For Insurance Company Use:
Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number
4113 Windfree Drive
City College Station StateTXZIP Code 77845 Company NAIC Number
SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION (CONTINUED)
Copy both sides of this Elevation Certificate for (1) community official, (2) insurance agent/company, and (3) building owner.
Comments BENCHMARK: Chiseled square in S.W curbline of Windfree Dr. located 295.5' S.E. of the centerline of Southern Plantation Dr.
Elevation = 283.18; THE ELEVATION SHOWN IN B.9 & ON THE PLAT FOR THIS LOT IS A MINIMUM OF 1' ABOVE THE CALCULATED BASE FLOOD
& REPRESENTS THE LOWEST HABITABLE FLOOR ELEV. FOR THE LOT AS REQUIRED BY CITY OF C/S STORMWATER MGMT ORDINANCE
Signature <r Ac/�� uate usrzitzuui
❑Check here if attachments
SECTION E - BUILDINd ELEVATION INFORMATION (SURVEY NOT REQUIRED) FOR ZONE AO AND ZONE A (WITHOUT BFE)
For Zones AO and A (without BFE), complete Items El-E5. If the Certificate is intended to support a LOMA or LOMR-F request, complete Sections A, B,
and C. For Items El-E4, use natural grade, if available. Check the measurement used. In Puerto Rico only, enter meters.
E1. Provide elevation information for the following and check the appropriate boxes to show whether the elevation is above or below the highest adjacent
grade (HAG) and the lowest adjacent grade (LAG).
a) Top of bottom floor (including basement, crawl space, or enclosure) is ❑ feet ❑ meters ❑ above or ❑ below the HAG.
b) Top of bottom floor (including basement, crawl space, or enclosure) is ❑ feet ❑ meters ❑ above or ❑ below the LAG.
E2. For Building Diagrams 6-8 with permanent flood openings provided in Section A Items 8 and/or 9 (see page 8 of Instructions), the next higher floor
(elevation C2.b in the diagrams) of the building is ❑ feet ❑ meters ❑ above or ❑ below the HAG.
E3. Attached garage (top of slab) is ❑ feet ❑ meters ❑ above or ❑ below the HAG.
E4. Top of platform of machinery and/or equipment servicing the building is ❑ feet ❑ meters ❑ above or ❑ below the HAG.
E5. Zone AO only: If no flood depth number is available, is the top of the bottom floor elevated in accordance with the community's floodplain management
ordinance? ❑ Yes ❑ No ❑ Unknown. The local official must certify this information in Section G.
SECTION F - PROPERTY OWNER (OR OWNER'S REPRESENTATIVE) CERTIFICATION
The property owner or owner's authorized representative who completes Sections A, B, and E for Zone A (without a FEMA-issued or community -issued BFE)
or Zone AO must sign here. The statements in Sections A, B, and E are correct to the best of my knowledge.
Property Owner's or Owner's Authorized Representative's Name
Address City State ZIP Code
Signature Date Telephone
Comments
❑ Check here if attachments
SECTION G - COMMUNITY INFORMATION (OPTIONAL)
The local official who is authorized by law or ordinance to administer the community's floodplain management ordinance can complete Sections A, B, C (or E),
and G of this Elevation Certificate. Complete the applicable item(s) and sign below. Check the measurement used in Items G8. and G9.
G1. ❑ The information in Section C was taken from other documentation that has been signed and sealed by a licensed surveyor, engineer, or architect who
is authorized by law to certify elevation information. (Indicate the source and date of the elevation data in the Comments area below.)
G2. ❑ A community official completed Section E for a building located in Zone A (without a FEMA-issued or community -issued BFE) or Zone AO.
G3. ❑ The following information (Items G4.-G9.) is provided for community floodplain management purposes.
G4. Permit Number G5. Date Permit Issued G6. Date Certificate Of Compliance/Occupancy Issued
G7. This permit has been issued for: ❑ New Construction ❑ Substantial Improvement
G8. Elevation of as -built lowest floor (including basement) of the building: ❑ feet ❑ meters (PR) Datum
G9. BFE or (in Zone AO) depth of flooding at the building site: ❑ feet ❑ meters (PR) Datum
Local Official's Name Title
Community Name Telephone
Signature Date
Comments
Check here if attachments
FEMA Form 81-31, February 2006 Replaces all previous editions
BUILDING PERMIT
CITY OF C"rY�E STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 07-00000463 Date 3/08/07
Property Address . . . . . . 4113 WINDFREE DR
Property ID: 569500-1950-0060
R #: R304151
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . .
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 140646
Owner Contractor
------------------------ ------------------------
ED FROEHLING BUILDER INC ED FROEHLING BUILDERS
3887 HIGH LONESOME 3887 HIGH LONESOME RD
COLLEGE STATION TX 778459443 COLLEGE STATION TX 77845
(979) 776-8266
--- Structure Information 000 000 SINGLE FAMILY
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info . . . . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID YES
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 2131.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 2.00
NUMBER OF BEDROOMS 4.00
SEWER TYPE PUBLIC
TAZ 422.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc KW
Permit Fee . . . . 583.00 Plan Check Fee .00
Issue Date . . . . 3/08/07 Valuation . . . . 140646
Expiration Date . . 9/04/07
Qty Unit Charge Per Extension
BASE FEE 460.00
41.00 3.0000 THOU BLDG, VAL 100001-500000 123.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
�REPR
------
-((��--s---------- ------ -- -- ------------
BUILDING D Z4T.ATIV��I P
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979).764-3496
Application Number 07-00000463
Page 2
Date 3/08/07
Special Notes and Comments
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELEVATION CERTIFICATE REQUIRED - PROVIDE ELEVATION
CERTIFICATE PRIOR TO SLAB INSPECTION AND A SECOND
CERTIFICATE PRIOR TO FINAL INSPECTION/C.O.
Minimum Finished Floor is 283.0'
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPR
BUILDING
APPLICANT
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 3
Application Number . . . . . 07-00000463 Date 3/08/07
----------------------------------------------------------------------------
Special Notes and Comments
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN.CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED
- --- ---, 0 VOLT W/BATTERY
--------------------------- - -- ------------
BUILDING DEPT REPRESENTATIVE: /�! -
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page
4
Application Number . . . . . 07-00000463 Date
3/08/07
----------------------------------------------------------------------------
Special Notes and Comments
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND
CLOTHES DRYERS.
Narrow Wall Bracing Fully Sheathed with APA Garage Framing
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
------------------------------
---------------------------
Permit Fee Total 583.00 583.00 .00
.00
Plan Check Total .00 .00 .00
.00
Other Fee Total 750.00 750.00 .00
.00
Grand Total 1333.00 1333.00 .00
.00
BUILDING L
APPLICANT:
APPLICATION FOR BUILDING PERMIT
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
CITY OF COLLEGE STATION WWW.CSTX.GOV
Planning d Dcvtldpment Sriviai
DATE: TRCC REG
APPLICATION #
TEMP POLE #
W,
AD OCATION: NV kJ KIVIII!--
LOT BLOCK 1% — SUBDIVISION SEC/PH�_-�
EM"BUSIlkM WNER NAME: PHONE:
CONT R/HOMEOWNER: Fit) �Rosau !4 PHONE: 7d7!o' 113Z1i(0
rn
ON T ' RADDRESS: 3eb% 14ICyLoOugpME Ro• GSTX 771945-
0 LE '� PLUMBER:
HVAC: GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION - MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ON
DUPLEX (Landscape Plans) REMODEL/RENOVATION* SWIMMING F
` J. t)��
-''—�DESCRIPTION OF WORK:
�r1 PROPOSED USE:
q\v HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPPRJ
VALUATION: $ TOTAL AREA: Z (0(0D HEATED AREA: Z I3
(Cost of Lat;.,-d`nd Materials)
U r UBLIC SEWER
❑ SEPTIC/TREATMENT SYSTEM
u
R SEWER TAP:
,E 11
WATER TAP: ij
SIZE
❑ OTHER TAP:
NUMBER OF BEDROOMS: 4
NUMBER OF BATHROOMS: 2
INTERIOR WALL TYPE: 514�"ROCIL
EXTERIOR WALL TYPE: I Ater.
FOUNDATION TYPE: SLAS 04 Q��tWf
SIZE
EMP POLE
ROOF TYPE:
�M
F' tri
GARAGE TYPE: SINGLE F]
DOUBLE [je TRIPLE
ATTACHED [2r
DETACHED CARPORT
;;�-�Am
SIGNATURE OF APPLICANT:
A (0".A
*If proposed work involves new co'frPmerod
Mjtr-uctitqfc. e i prove
s/renovations to an existing
commercial property, building elevations arTireq&'4.e��
l
Official Use Only
jT-,:,16 —o'7
Plans Examiner
Zoning Official
/Z23 fAiw • FF . / 84- V&41(ow Comments:
GAO-41lt W1 P Q NO
Q (y S-tj%.� (4,Jllpe
Fire Marshall
0.1
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls 3
Insulation R value of ceiling 1 (flat areas) 30
Insulation R value of ceiling 2 (vaulted areas/no attic) 1 tv-,
Glazing SHGC ° AC) /
Glazing U-Factor
R value of ductwork �P
A/C SEER Rating
V
reo. I4. [dui [:3urm wcliure a Browne cng; aurveying, No. ZOO r. I/I
.Q/ b W I G'QIX�M.i}�t` E %l°.f7v9 IMIAS dW
Lot 06 Took DO.dwg l 1
NOW grq W.foeL� �-
Yd.7In
343. .
Now or F� T
J 44$6,j8
20' F.U.E. r _
�--_ • _ 29.r
(� S.L.) 3
I I `'•0' � 1 y
7.8' '
Zot d BlooJr 50
N I I shonondooh Rho" to
qw
I
or
r r r
Windfiee Qn've
50' R.aW. M 27' POwmmt
W .. 73AX Pg. 101
Scale: 1" - 2D'
CURVE m&CL
\ CURVE DELTA RADIUS LPNCTH CHORD. Oft
C1 ♦ 60'12` KW 40.00' N 16.25'03' Y1W
bP
� �1
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# 07 _ /
DATE:
BUILDING ADDRESS: -
q1 13 Ih
I. Foundation Requirements
N
A.
Concrete minimum f'c of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F.
Wood foundation details indicated
K
II. Framing: Floor, Wall, Ceiling and Roof Requirements
N
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
OK
1. One -hour rated extending to roof deck
K
E.
Header sizes indicated on plans
NA(OK)
F.
Emergency bedroom egress
1. Exit direct to outside
2. O enable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
O enable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
III. Stairway Requirements
OK
A. Stairway Details
(NAJOK
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than twenty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements to be indicated onplans)N
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
NAT9
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
b
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
N O
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
NA/
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
N K
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
NAtW
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
NA/
Maximum drive width for residence is 28' combined for circular
Minimum 30 feet from driveway to side(intersecting) street
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
NA/
Does not block any water course or divert any flow
Elevation certificate needed 2 O
"APPROVED PLANS PER IRC SECTION R106.3.1."
"14 ?- -016-0 ;
"—PLANS EXAMINER DATE
Permit Number
REScheck Compliance Certificate Checked By/Date
2000 IECC
REScheckSoftware Version 3.5 Release lb
Data filename: C:\Program Files\Check\REScheck\4113WF.rck
TITLE: 4113 WINDFREE DRIVE
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 02/22/07
DATE OF PLANS: NOVEMBER 1, 2002
PROJECT INFORMATION:
HOME FOR MARTINEZ
LOT 6 BLOCK 50, SHENANDOAH PHASE 19
COMPANY INFORMATION:
ED FROEHLING BUILDER, INC
NOTES:
ORIGINALLY 1208 SB (LEMKE PLAN)
COMPLIANCE: Passes
Maximum UA = 700
Your Home UA = 570
18.6% Better Than Code (UA)
Maximum SHGC = 0.40
Your SHGC = 0.36
Gross
Glazing
Area or
Cavity
Cont. or Door
Perimeter
R-Value
R-Value U-Factor
UA
Ceiling 1: Flat Ceiling or Scissor Truss
2131
30.0
0.0
75
Wall 1: Wood Frame, 16" o.c.
430
15.0
0.0
26
Window 1: Metal Frame:Double Pane with Low-E
60
0.640
38
SHGC: 0.40
Bldg. faces 270 deg. from North; Comp. orient.: Front
Projection factor: 0.18
Door 1: Solid
38
0.800
30
Wall 2: Wood Frame, 16" o.c.
490
15.0
0.0
33
Window 2: Metal Frame:Double Pane with Low-E
66
0.640
42
SHGC: 0.40
Bldg. faces 270 deg. from North; Comp. orient.: Left Side
Projection factor: 0.18
Wall 3: Wood Frame, 16" o.c.
403
15.0
0.0
24
Window 3: Metal Frame:Double Pane with Low-E
72
0.640
46
t Jr 'or, ..
SHGC: 0.40
Bldg. faces 270 deg. from North; Comp. orient.: Back
Projection factor: 0.27
Door 2: Glass
18
0.580 10
SHGC: 0.78
Bldg. faces 270 deg. from North; Comp. orient.: Back
Projection factor: 0.81
Wall 4: Wood Frame, 16" o.c.
398 15.0 0.0
29
Window 4: Metal Frame:Double Pane with Low-E
27
0.640 17
SHGC: 0.40
Bldg. faces 270 deg. from North; Comp. orient.: Right Side
Projection factor: 0.27
Floor 1: Slab-On-Grade:Unheated
192 0.0
200
Insulation depth: 0.0'
Air Conditioner 1: Electric Central Air, 13 SEER
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications,
and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC
requirements in RESche sion 3.5 Releas lb (f erly MECch and to comply with t e mandato requirements listed in
the RES checkI ction Chec t.
$1
f4 W I
Builder esigner Date ��