INSPECTION TICKET PAGE 6
City of
------------------------------------------------------------------------------------------------
College Station
INSPECTOR: BUILDING INSPECTOR DATE 8/08/07
ADDRESS
. : 2007 MOSES
CREEK
CT SUBDIV: WILLIAMS CREEK PH 1
CONTRACTOR ELEGANT
LIVING HOMES, INC PHONE (979) 823-0638
OWNER
PHONE
PARCEL
-
-
APPL NUMBER: 07-00000459
------------------------------------------------------------------------------------------------
RESIDENTIAL, 1 UNIT DETACHED NEW
PERMIT:
BLDG 00 BUILDING PERMIT
REQUESTED
INSP
DESCRIPTION
TYP/SQ
COMPLETED
RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01
,.�4/03/07
JGM
BLDG, FOUNDATION -SLAB TIME: 17:00
4/03/07
AP
April 3, 2007 11:21:23 AM kwolfe.
Strings On Setbacks O.K.
Slab Ground Installed
Bill 01
5/07/07
JGM
BLDG, FRAMING TIME: 17:00
5/08/07
DA
May 7, 2007 9:45:42 AM kwolfe.
05/08/2007 04:51 PM JGM PDA
need toi sheetrock over fireplace, flue pipe needs proper
clearance
B115 02
5/09/07
RH
BLDG, FRAMING TIME: 17:00
5/09/07
AP
May 9, 2007 11:26:51 AM glsouth.
B130 01
5/10/07
RH
BLDG, INSULATION TIME: 17:00
5/11/07
AP
May 10, 2007 2:52:00 PM kwolfe.
B125 01 8 08/ 7 BLDG, FINAL TIME: 17:00
a'7 Apoc August 8, 2007 1:32:37 PM glsouth.
-------------------------------------- COMMENTS AND NOTES----------------------------
IJ�
Date: 8/9/2007
Inspection Comments for Finals
Permit Year: 7 Permit Number: 459
Address: 2007 MOSES CREEK CT
Insp.
inspection Type Code
Description
p.
status
Inspection Result Comments
B100
BLDG, FOUNDATION -SLAB
IC
Strings On Setbacks O.K.
B100
BLDG, FOUNDATION -SLAB
IC
Slab Ground Installed
B115
BLDG, FRAMING'
IC
05/08/2007 04:51 PM JGM PDA
B115
BLDG, FRAMING
IC
need toi sheetrock over fireplace, flue pipe needs proper
B115
BLDG, FRAMING
IC
clearance
Ell
ELEC, ROUGH IN
IC
05/04/2007 10:36 AM RH PDA
Ell
ELEC, ROUGH IN
IC
Need to add ground stingers to metal exterior boxes by
E110
ELEC, ROUGH IN
IC
framing inspection.
P125
PLBG, FINAL
IC
Pressure Test Not Holding
P125
PLBG, FINAL
IC
Need Walkway To Waterheater
Page 1
WFO880031 / 001 City of College Station PAGE 1
REQ. DATE: 03/09/07 O� 03/09/07 15:58:18
LOCATION: 2007 MOSES CREEK CT LOC ID: 201564
REQUESTOR: ELEGANT LIVING HOMES, INC ORIGIN: CUSTOMER -WALK IN
REQ USER: KWOLFE AUTH USER:KWOLFE WRK TYPE:
TEMP POLE PASSED
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 03/09/07 SCHED COMPLETION: 03/09/07
********************************************************************************
JOB ORDER RESULT COMvEMTS
(8/10/2007) Gina Southerland - Re: Calling for CO @ 2007 Moses Creek Cf_ _ �_ _ _ Page 1
From: Paul Schoenfeld
To: Amber Carter; Benjamin McCarty; Chris Haver; Gina Southerland; Joe G...
Date: 8/10/2007 8:33 AM
Subject: Re: Calling for CO @ 2007 Moses Creek Ct
All ok.
Paul
>>> Kim Wolfe 8/9/2007 12:05 PM >>>
any issues?
BP # 07-459
Thanks
Kimberly Wolfe, CPS/CAP
City of College Station
Planning & Development Services
(979)764-3570
www.cstx.4ov
AUG.16.2007 3;30PM Brazos County Health Departm.ent�.y NO.8205 P. 2
Brazos County Health Department
201 North Texas Ave. !� /111
r
Bryan, TX 77803-5317
(979) 361-4440
LICENSE TO OPERATE AN ON SITE SEWAGE FACILITY
THIS IS TO CERTIFY that the on site sewage facility owned by.
KRATZ, DAVID AND AMY
MOSES CREEK CT 2007, College Station TX 77845
WILLIAMS CREEK
Block: 2 Lot: 5
ossr #: 2007 - 3385
Grid:
Certificate of Compliance: CITY OF CS
Installed By: WAGER, JAY C.-WAGER BACKHOE Bedrooms: 3
Engineered By:GONZALEZ, STEVEN. PREMIER ENVIRONMENTAL DESIGNS Employees: 0
Date Purchased: 06/21/07 Final Inspection Date- 08/16/07 MaxGPD: 433
Disinfectant: Liquid Chi
The private sewage facility licensed above was installed according to the current and
minimum guidelines of the Texas Commission on Environmental Quality (TCEQ) and
Brazos County.
This aerobic system with soray dispersal requires a disinfectant for final treat naent of the
sprayed effluent. It is the responsibility of the homeowner to monitor the disinfectant
and to add more when needed. (Swimming pool chlorine tablets are not acceptable
substitutes). Under no circumstance are any food crops or edible foods to be grown in
the spray area. Mowing of the sprayfield on a regular basis should also be done to help
with the evaporation process.
The current maintenance contract for this system will expire 2-years from the above final
inspection date. A new maintenance contract must be in force at that time, and a copy of
the new contract filed With this office 30 days before contract expires.
This is a NON -TRANSFERABLE license. Upon transfer of ownership, the new owner
shall be required to transfer the original license into his/her name. Should the system
malfunction in the future, it will be the licensee's responsibility to bring the system in
compliance with all current state and county regulations.
This license does not extend to the material's, workmanship, or fabrication, of the
system, so as to expressly or impliedly grant the owner, or installer of the system any
warranty by / or tights against Brazos County and / or the Brazos County Health
Department, as to the quality or durability of the system, nor compliance with licensee's
individual specifications and requirements, but solely relates to the system meeting the
requirements of the above named regulatory body in effect as of this date.
INSPECTION ON 8116107-SYSTEM APPROVED. SPRAYFIELD MUST BE GRASSED. KEEP UNDERBRUSH CLEARED AWAY
SPRAYHEADS.
R-10
Environm tal Health Specialist
BUILDING -PERMIT
CITY OF COLLt CzE_, EAT ION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 0-7-00000459 Date 3/09/07
Property Address . . . . . . 2007 MOSES CREEK CT
Property ID: - -
R #: R*****
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . WILLIAMS CREEK PH 1
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . RURAL RESIDENTIAL SUB.
Application valuation ' 236160
Owner
Contractor
------------------------
------------------------
ELEGANT LIVING HOMES, INC
P.O. BOX 7063
BRYAN
TX 77805
(979) 823-0638
--- Structure Information 000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
2761.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
3.00
NUMBER OF BEDROOMS
4.00
SEWER TYPE
SEPTIC
TAZ
329.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
GS
Permit Fee . . . .
871.00 Plan Check Fee
.00
Issue Date . . . .
3/09/07 Valuation . . .
. 236160
Expiration Date . .
9/05/07
Qty Unit Charge
Per
Extension
BASE FEE
460.00
137.00 3.0000
THOU BLDG, VAL 100001-500000
411.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS
THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL
BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS
OPENING (MINIMUM ROUGH -FRAMED SIZE
22"
-------------------
BUILDING DE
APPLICANT:
BUILDING PERMIT
CITY OF COLLAGE &TATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number 07-00000459
Page 2
Date 3/09/07
Special Notes and Comments
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
OBTAIN HEALTH DEPARTMENT APPROVAL: CALL 979-361-4440 FOR
MORE INFORMATION. THIS INCLUDES SEPTIC SYSTEMS INSTALLS.
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH EASURED AT THE
-------------------------�------------------- ------------
BUILDING DEPT„R'EP?aSRaP1,dVAi
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE t'TATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page 3
Application Number 07-00000459 Date 3/09/07
----------------------------------------------------------------------------
Special Notes and Comments
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERI L FROM LAB AREA19601 ---------
------------------------------------------ ---
- -------
BUILDING DEPTi^/RE4RE$ Tt.WIXE :
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page 4
Application Number 07-00000459 Date 3/09/07
----------------------------------------------------------------------------
Special Notes and Comments
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
Minimum Finished Floor 236.0 F.F. For Sewer
12" Culvert Needed for Driveway
Narrow Wall Bracing Prescriptive Bracing Per Plans
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
---------------------------------------------------------
Permit Fee Total
Plan Check Total
Grand Total
BUILDING DE
APPLICANT:
871.00 871.00
.00 .00
871.00 871.00
.00 .00
.00 .00
.00 .00
TEMPORARY POLE PERMIT
._� CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 07-00000460 Date 3/09/07
Property Address . . . . . . 2007 MOSES CREEK CT
Property ID: - -
Application type description TEMP POLE
Subdivision Name . . . . . . WILLIAMS CREEK PH 1
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . RURAL RESIDENTIAL SUB.
Application valuation . . . . 0
Owner
Contractor
------------------------
------------------------
ELEGANT LIVING HOMES,
INC
P.O. BOX 7063
BRYAN
TX 77805
(979) 823-0638
-------------------------=--------------------------------------------------
Permit . . . . .
. TEMP POLE
PERMIT
Additional desc .
. GS
Permit Fee . . .
. 20.00
Issue Date . . .
. 3/09/07
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary
Charged
Paid Credited
------------------------------
Due
-----------------
Permit Fee Total
----------
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
-------------------
BUILDING DE
APPLICANT:
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX
Planning d Development Services
WWW.CSTX.GOV
For Office Use Only
DATE: U 2 ` f'7-5-fYCOC EG
APPLICATION # ,,V-7 - 541
TEMP POLE # 07 - 1 & D
ADDRESS/LOCATIO_N:/2007 Moses Creek Court, College Station, Texas 77845
LOT 5 C/ BLOCK 2 '� SUBDIVISION WILLIAMS CREEK
SEC/PH 1
BUSINESS/OWNER NAME: ELH-Elegant Living Homes, Inc. PHONE:979-823-0638
I CONTRACTOR/HOMEOWNER: Same
I CONTRACTOR ADDRESS: P. O. Box 7063, BRYAN, TEXAS 77805
I ELECTRICIAN: Thomas Electric
PHONE: FAx: 979-823-1606
PLUMBER: H & A Plumbinq
HVAC: Moores A./C & Heat GOOD CENTS (Residential only): N/A
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) x NEW CONSTRUCTION ` SLAB ONLY
�1 DUPLEX (Landscape Plans REMODEURENOVATIOW SWIMMING POOL
Required)
DESCRIPTION OF WORK: Construction of new single family, single story home
�Vr
Wt
STRUCTURE USE: Residential
` HOMEOWNER ASSOC IATIO N/ARC H ITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: Yes
TEXAS ACCESSIBILITY STANpARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $236160. TOTAL AREA:3572 HEATED AREA: 2761
(Cost of Labor and Materials)
F PUBLIC SEWER
FX SEPTIC/TREATMENT SYSTEM
SEWER TAP:
SIZE
❑ WATER TAP: WELLBORN
SIZE
OTHER TAP:
SIZE
❑X— TEMP POLE B_I"U
GARAGE TYPE: SINGLE
ATTACHED
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS: 3
INTERIOR WALL TYPE: STUD/ SHEETROCK
EXTERIOR WALL TYPE: STUD/SHEETROCK/BRICK
FOUNDATION TYPE: CONCRETE ON GRADE
ROOF TYPE: COMPOSITION
DOUBLE FX ] TRIPLE a
DETACHED F_� CAV-Q�T
SIGNATURE OF APPLICANT ' co
*If proposed work involves new c m rcial construction or facade improvements/renovations to an existing
commercial property, building elevations are required.
Official Use Only
CQ
pa�nents:
--0 -/ YES r NO
V
.2 36
-�12Z w ,dam- cam, l
Plans Examiner
Zoning Official
Energy Code Compliance Information
% Glazing of exterior walls 14.2 ✓
Insulation R value of exterior walls 13
Insulation R value of ceiling 1 (flat areas) 30
Insulation R value of ceiling 2 (vaulted areas/no attic) N/A
I Glazing SHGC .36 /
I Glazing U-Factor .60 ./
R value of ductwork 6
A/C SEER
r l / i ins line represents me closet point to me wont property tine on a meancermg rear property line.
---------------saa+--- ------ ---
Fc�aor�'
cvu" 1
Holnes
2007 Moses Creek Ct.
Lot 5, Block 2, Phase 1
Rear setback Williams Creek Subdivision
Scale: V = 30'
0
T
Building Outline
0
N
__________________________________________________________________________ ________________ ______________________________
Front setback
b
6n
Electrical
Transformer
r-
I �
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# 0,7 _ 4/5-
DATE:
.2_ oZ
BUILDING ADDRESS:
0
I. Foundation Requirements
N
A.
Concrete minimum f'c of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F.
Wood foundation details indicated
OK
II. Framing: Floor, Wall, Ceiling and Roof Requirements
NA/
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
&JOK
1. One -hour rated extending to roof deck
KOOK
E.
Header sizes indicated on plans
N
F.
Emergency bedroom egress
1. Exit direct to outside
2. O enable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
O enable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
III. Stairway Requirements
OK
A. Stairway Details
NlgO K
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than twenty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements to be indicated onplans)
N O
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening ? 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
NA/ey
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
NA/
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
NA/
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
Vill. Energy Requirements
N Af K
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N K
Maximum drive width for residence is 28' combined for circular
Minimum 30 feet from driveway to side(intersecting) street
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
N
Does not block any water course or divert any flow
Elevation certificate needed
PA -
"APPROVED PLANS PER IRC SECTION R106.3.1."
PLANS EXAMINER
DATE
REScheck Software Version 4.0.1
Compliance Certificate
Project Title: The Kratz Residence
Report Date: 02/22/07
Data filename: C:\Program Files\Check\REScheck\2007 Moses Creek.rck
Energy Code: 2000 IECC
Location: College Station, Texas
Construction Type: Single Family
Glazing Area Percentage: 18%
Heating Degree Days: 1788
Construction Site:
2007 Moses Creek Court
College Station, TX 77845
Owner/Agent:
Bill Morris
ELH-Elegant Living Homes, Inc.
P. O. Box 7063
Bryan, TX 77805
979-823-0638
cam@elegantliving-bcs.com
Designer/Contractor:
Bill Morris
ELH-Elegant Living Homes, Inc.
P. O. Box 7063
Bryan, TX 77805
979-823-0638
bil@elegantliving-bcs.com
Compliance: Passes Maximum UA: 716 Your Home UA, 554 -=> 22.6% Better Than Code PA ,:E
Maximum SHGC: •i i
Ceiling 1: Flat Ceiling or Scissor Truss:
2761
0.0 30.0
86
Wall 1: Wood Frame, 16" o.c.:
2974
13.0 0.0
200
Window: 2870 Low E: Metal Frame with Thermal Break, Double
112
0.600
67
Pane with Low-E:
SHGC: 0.36
Window: 2810 Low E: Metal Frame with Thermal Break, Double
16
0.600
10
Pane with Low-E:
SHGC: 0.36
Window: 2080 Low E: Metal Frame with Thermal Break, Double
64
0.600
38
Pane:
SHGC: 0.36
Window: 2020 Low E Win: Metal Frame with Thermal Break,
8
0.600
5
Double Pane with Low-E:
SHGC: 0.36
Window: 6020 Low E: Metal Frame with Thermal Break, Double
24
0.600
14
Pane with Low-E:
SHGC: 0.36
Window: 3670 Low E: Metal Frame with Thermal Break, Double
24
0.600
15
Pane with Low-E:
SHGC: 0.36
Window: 2870 Low E: Metal Frame with Thermal Break, Double
131
0.600
78
Pane with Low-E:
SHGC: 0.36
Window: 5060 Low E-dbl: Metal Frame with Thermal Break,
30
0.600
18
Double Pane with Low-E:
SHGC: 0.36
Window: 1616 Low E: Metal Frame with Thermal Break, Double
7
0.600
4
Pane with Low-E:
SHGC: 0.36
Window: 4016 Low E: Metal Frame with Thermal Break, Double
6
0.600
4
Pane with low-E:
SHGC: 0.36
6068 Double door: Glass:
80
0.130
10
SHGC: 0.30
The Kratz Residence
Page 1 of 6
3068 Door: Glass: 36 0.130
SHGC: 0.30
Air Conditioner 1: Electric Central Air: 13 SEER
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in
REScheck Version 4.0.1 and to comply with the mandatory requirements listed in the RESche spe tion klist.
r� A . fqonas . I icc fir.& 1 Ax't U Z-2,2 -07
Warffd - Title Signature Date
Project Notes:
Please call when the permit is ready:
Bill 979-229-2045
Cindy 979-777-0703
Office 979-823-0638 Thank you!!
a
The Kratz Residence r Page 2 of 6
REScheck Software Version 4.0.1
Inspection Checklist
Date: 02/22/07
Ceilings:
❑ Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 continuous insulation
Comments:
Above -Grade Walls:
❑ Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation
Comments:
Windows:
❑ Window: 2870 Low E: Metal Frame with Thermal Break, Double Pane with Low-E, U-factor: 0.600
For windows without labeled U-factors, describe features:
Vanes Frame Type Thermal Break? Yes No
Comments: 2870 Low E Window
❑ Window: 2810 Low E: Metal Frame with Thermal Break, Double Pane with Low-E, U-factor: 0.600
For windows without labeled U-factors, describe features:
Vanes Frame Type Thermal Break? Yes No
Comments: 2816 Low E Transom
❑ Window: 2080 Low E: Metal Frame with Thermal Break, Double Pane, U-factor: 0.600
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break? Yes No
Comments: 2080 Low E Window
❑ Window: 2020 Low E Win: Metal Frame with Thermal Break, Double Pane with Low-E, U-factor: 0.600
For windows without labeled U-factors, describe features:
Vanes Frame Type Thermal Break? Yes No
Comments: 2020 Low E Window
❑ Window: 6020 Low E: Metal Frame with Thermal Break, Double Pane with Low-E, U-factor: 0.600
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break? Yes No
Comments: 6020 Low E Transom
❑ Window: 3670 Low E: Metal Frame with Thermal Break, Double Pane with Low-E, U-factor: 0.600
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break? Yes No
Comments: 3670 Low E Window
❑ Window: 2870 Low E: Metal Frame with Thermal Break, Double Pane with Low-E, U-factor: 0.600
For windows without labeled U-factors, describe features:
Vanes Frame Type Thermal Break? Yes No
Comments: 2870 Low E Window
❑ Window: 5060 Low E-dbl: Metal Frame with Thermal Break, Double Pane with Low-E, U-factor: 0.600
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break? Yes No
Comments: 5060 Low E-dbl
The Kratz Residence Page 3 of 6
f
❑ Window: 1616 Low E: Metal Frame with Thermal Break, Double Pane with Low-E, U-factor: 0.600
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break? Yes No
Comments: 1616 Low E window
❑ Window: 4016 Low E: Metal Frame with Thermal Break, Double Pane with Low-E, U-factor: 0.600
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break? Yes No
Comments: 4016 Low E Window
Doors:
❑ 6068 Double door: Glass, U-factor: 0.130
Comments: 6080 Door
❑ 3068 Door: Glass, U-factor: 0.130
Comments: 3068 Door
Heating and Cooling Equipment:
❑ Air Conditioner 1: Electric Central Air: 13 SEER or higher
Make and Model Number:
Solar Heat Gain Coefficient:
❑ The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values are determined in
accordance with the NFRC test procedure or taken from the default table.
Air Leakage:
❑ Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage are sealed.
❑ Recessed lights are 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from
combustible materials. If non -IC rated, fixtures are installed with a 3" clearance from insulation.
Materials Identification:
❑ Materials and equipment are installed in accordance with the manufacturer's installation instructions.
❑ Materials and equipment are identified so that compliance can be determined.
❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided.
❑ Insulation R-values and glazing U-factors are clearly marked on the building plans or specifications.
❑ Insulation is installed according to manufacturer's instructions, in substantial contact with the surface being insulated, and in a
manner that achieves the rated R-value without compressing the insulation.
Duct Insulation:
❑ Ducts in unconditioned spaces are insulated to R-5. Ducts outside the building are insulated to R-8.0.
Duct Construction:
❑ All joints, seams, and connections are securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric,
or tapes. Tapes and mastics are rated UL 181A or UL 181 B.
Exceptions:
Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa).
❑ The HVAC system provides a means for balancing air and water systems.
Temperature Controls:
❑ Thermostats exist for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or
cooling input to each zone or floor is provided.
Service Water Heating:
❑ Water heaters with vertical pipe risers have a heat trap on both the inlet and outlet unless the water heater has an integral heat
trap or is part of a circulating system.
❑ Circulating hot water pipes are insulated to the levels in Table 1.
Circulating Hot Water Systems:
❑ Circulating hot water pipes are insulated to the levels in Table 1.
The Kratz Residence Page 4 of 6
Swimming Pools:
El All heated swimming pools have an on/off heater switch and a cover unless over 20% of the heating energy is from non-depletable
sources. Pool pumps have a time clock.
Heating and Cooling Piping Insulation:
Lj HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to the levels in Table 2.
The Kratz Residence Page 5 of 6
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes
Insulation Thickness in Inches by Pine Sizes
Non -Circulating Runouts
Circulating Mains and Runouts
Heated Water
Up to 1"
Up to 1.25"
1.5" to 2.0"
Over 2"
Temperature (°F)
170-180
0.5
1.0
1.5
2.0
140-169
0.5
0.5
1.0
1.5
100-139
0.5
0.5
0.5
1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes
Insulation Thickness in Inches by Pipe Sizes
Fluid Temp.
Piping System Types
Range(°F)
2" Runouts 1" and Less
1.25" to 2.0"
2.5" to 4"
Heating Systems
Low Pressurerremperature
201-250
1.0
1.5
1.5
2.0
Low Temperature
120-200
0.5
1.0
1.0
1.5
Steam Condensate (for feed water)
Any
1.0
1.0
1.5
2.0
Cooling Systems
Chilled Water, Refrigerant and
40-55
0.5
0.5
0.75
1.0
Brine
Below 40
1.0
1.0
1.5
1.5
NOTES TO FIELD: (Building Department Use Only)