HomeMy WebLinkAboutADDN2007-00435BUILDING.PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ----------------------------------------------------------=-`--------------- Application Number . . . . . 07-00000435 Date 3/05/07 Property Address . . . . . . 1207 ROYAL ADELADE DR Property ID: 497900-0039-0130 R #: R114209 Tenant nbr, name . . . . . . ROOM ADDED OVER GARAGE Application type description RESIDENTIAL, ADDITION Subdivision Name . . . . . . PEBBLE CREEK Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . UNKNOWN Application valuation . . . . 20000 Owner Contractor ------------------------ ------------------------ TOOMBS, BARRY D & LINDA D S C STOKES CONSTRUCTION, INC 3736 RICE BLVD 5200 WHISTLING STRAITS CT HOUSTON TX 77005 COLLEGE STATION TX 77845 (979) 690-6626 --- Structure Information 000 000 ADDITION Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 550.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 1.00 NUMBER OF BEDROOMS 1.00 SEWER TYPE PUBLIC TAZ 411.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . NC Permit Fee . . . . 110.00 Plan Check Fee .00 Issue Date . . . . 3/05/07 Valuation . . . . 20000 Expiration Date . . 9/01/07 Qty Unit Charge Per Extension BASE FEE 15.00 19.00 5.0000 THOU BLDG, VAL 1001-50000 95.00 ---------------------------------------------------------------------------- Special Notes and Comments This permit is to finish out area above garage and convert into a gameroom. Access is to be from second floor hall down a few stairs which will require a handrail. Storage ------------------- BUILDING DE APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION. 1101 TEXAS AVE ` COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 2 Application Number . . . . . 07-00000435 Date 3/05/07 ---------------------------------------------------------------------------- Special Notes and Comments closet not to have capability of hanging clothes, that would give in bedroom characteristics and therefore have different code requirements. The other active permit on the main house is 06-3490. Garage ceiling must have 5/8" Type X sheetrock when there is Habitable space above the garage. Make sure garage ceiling is 5/8" type X sheetrock. ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 STAIRS SHALL COMPLY WITH SECTION R-311 (2003 IRC) WITH A CONTINUOUS HANDRAIL OR SECTION 1009 (2003 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS. ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total Plan Check Total Grand Total BUILDING DE APPLICANT: 110.00 110.00 .00 .00 .00 .00 .00 .00 110.00 110.00 .00 .00 BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 07-00000435 Date 3/05/07 Property Address . . . . . . 1207 ROYAL ADELADE DR Property ID: 497900-0039-0130 R #: R114209 Tenant nbr, name . . . . . . ROOM ADDED OVER GARAGE Application type description RESIDENTIAL, ADDITION Subdivision Name . . . . . . PEBBLE CREEK Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . UNKNOWN Application valuation . . . . 20000 Owner Contractor ------------------------ TOOMBS, BARRY D & ------------------------ LINDA D S C STOKES CONSTRUCTION, INC 3736 RICE BLVD 5200 WHISTLING STRAITS CT HOUSTON TX 77005 COLLEGE STATION TX 77845 (979) 690-6626 --- Structure Information 000 000 ADDITION Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 550.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 1.00 NUMBER OF BEDROOMS 1.00 SEWER TYPE PUBLIC TAZ 411.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . NC Permit Fee . . . . 110.00 Plan Check Fee .00 Issue Date . . . . 3/05/07 Valuation . . . . 20000 Expiration Date . . 9/01/07 Qty Unit Charge Per Extension BASE FEE 15.00 19.00 5.0000 THOU BLDG, VAL 1001-50000 95.00 ---------------------------------------------------------------------------- Special Notes and Comments This permit is to finish out area above garage and convert into a gameroom. Access is to be from second floor hall down a few stairs which will require a handrail. Storage - APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 07-00000435 Page 2 Date 3/05/07 Special Notes and Comments closet not to have capability of hanging clothes, that would give in bedroom characteristics and therefore have different code requirements. The other active permit on the main house is 06-3490. Garage ceiling must have 5/8" Type X sheetrock when there is Habitable space above the garage. Make sure garage ceiling is 5/8" type X sheetrock. ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 STAIRS SHALL COMPLY WITH SECTION R-311 (2003 IRC) WITH A CONTINUOUS HANDRAIL OR SECTION 1009 (2003 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS. ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total 110.00 110.00 Plan Check Total .00 .00 Grand Total 110.00 110.00 BUILDING DE APPLICANT: .00 .00 .00 .00 .00 .00 CITY OF COLLEGE STATION Planning. d Devdopmeni Seivicer ADDRESS/LOCATION: APPLICATION FOR BUILDING PERMIT 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX A — For OfOce Use Only a,oi � b .7 DATE: TRCC REG APPLICATION # TEMP POLE # LOT BLOCK SUBDIVISION SEC/PH BUSINESS/OWNER NAME:f�/� PHONE: CONTRACTOR/HOMEOWNER: C- - C o XX�I PHONE: CONTRACTOR ADDRESS: ELECTRICIAN: HVAC: PLUMBER: _ GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY EMOLITION (Asbestos Survey) NEW CONSTRUCTION ` SLAB ONLY DUPLEX (Landscape Plans) REMODEL/RENOVATION' SWIMMING POOL TCA IT If' A AI/1 r]%/ DESCRIPTION PROPOSED U HOMEOWNER A; TEXAS ACCESSI VALUATION: $ ❑ PUBLIC SEWI SEPTIC/TREE ❑ SEWER TAP: WATER TAP: ❑ OTHER TAP: TEMP POLE GARAGE TYF SIGNATURE Of 'If proposed wor commercial proF Plan, Ener. Code+Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER Rating I 64ja- 0