(8/10/2007) Gina Southerland - Re: Calling for CO @ y2118 Cascades. Dr Page 1
From: Terry Boriskie
To: Amber Carter; Benjamin McCarty; Chris Haver; Gina Southerland; Joe G...
Date: 8/10/2007 9:29 AM
Subject: Re: Calling for CO @ 5218 Cascades Dr
Clay Kolby at 777-9840 has been notified.
Terry Boriskie
City of College Station
Residential Plans Examiner
979-764-3744
>>> Paul Schoenfeld 8/10/2007 8:33 am >>>
Water ok.
Sewer buried flagged.
Paul
>>> Kim Wolfe 8/9/2007 8:25 AM >>>
any issues?
BP # 07-420
Thanks
Kimberly Wolfe, CPS/CAP
City of College Station
Planning & Development Services
(979)764-3570
www.cstx.gov
PREPARED 8/09/07, 7:47:39 INSPECTION TICKET PAGE 1
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 8/09/07
------------------------------------------------------------------------------------------------
ADDRESS . : 5218 CASCADES DR SUBDIV: PEBBLE CREEK
CONTRACTOR CLAY KOLBY HOMEBUILDING, LLP PHONE (979) 777-9840
OWNER . . PHONE
PARCEL . . 497900-0946-0100
APPL NUMBER: 07-00000420 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 3/08/07 JGM BLDG, FOUNDATION -SLAB TIME: 17:00
3/08/07 AP March 8, 2007 7:59:26 AM kwolfe.
Strings On Setbacks O.K.
Slab Ground Installed
B145 01 3/28/07 JGM BLDG, EXT. SHEATHING FASTENER TIME: 17:00
3/29/07 AP March 28, 2007 1:10:45 PM kwolfe.
B115 01 5/04/07 JGM BLDG, FRAMING TIME: 17:00
5/04/07 AP May 4, 2007 9:04:49 AM ncochran.
B130 01 5/15/07 BH BLDG, INSULATION TIME: 17:00
5/14/07 AP May 14, 2007 3:45:23 PM glsouth.
May 14, 2007 3:45:28 PM glsouth.
B125 01 8/09/0 BI BLDG, FINAL TIME: 17:00
S ) *-p or,- August 9, 2007 7:47:26 AM kwolfe.
-------------------------------------- COMMENTS AND NOTES--------------------------------------
0
Date: 8/9/2007
Inspection Comments for Finals
Permit Year: 7 Permit Number: 420
Address: 5218 CASCADES DR
Insp.
inspection Type Code
p.
Status
Inspection Result Comments
Description
B100
BLDG, FOUNDATION -SLAB
IC
Strings On Setbacks O.K.
B100
BLDG, FOUNDATION -SLAB
IC
Slab Ground Installed
B130
BLDG, INSULATION
IC
May 14, 2007 3:45:28 PM glsouth.
Page 1
WF0881040 / 001 City of College Station
PAGE 1
REQ. DATE: 03/15/07 03/15/07 8:45:07
LOCATION: 5218 CASCADES DR LOC ID: 205954
REQUESTOR: CLAY KOLBY HOMEBUILDING, LLP ORIGIN: CUSTOMER -WALK IN
REQ USER: KWOLFE AUTH USER:KWOLFE WRK TYPE:
TEMP POLE PASSED
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 03/15/07 SCHED COMPLETION: 03/15/07
********************************************************************************
JOB ORDER RESULT COM4ENTS
(5/15/2007 Kim Wolfe - Insulation request inspection result, 5218 Cascades, #07-420 Page 1
From: Brian Henry
To: Southerland, Gina
Date: 5/14/2007 2:54 PM
Subject: Insulation request inspection result, 5218 Cascades, #07-420
CC: Cochran, Nicole; Wolfe, Kim
Print for file
Inspected insulation, 5218 Cascades, #07-420, Clay Kolby Homes, 5-14-07
Inspection result: Inspected OK for Good Cents
Notes:
Seal duct chase at attic in upstairs bathroom.
WFO876071 / 001 City of College Station
PAGE 1
REQ. DATE:
02/22/07
02/22/07
10:01:34
LOCATION:
5218 CASCADES DR
LOC ID:
205954
REQUESTOR:
CLAY KOLBY HOMEBUILDING ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER: KWOLFE
WORK TYPE:
ROUT
4" SWR TAP
3/4" WTR TAP
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT SET
READY
SCHED START:
02/22/07 SCHED COMPLETION:
02/22/07
********************************************************************************
JOB ORDER RESULT COMIlI TrS
BUILDING PERMZT,,,4
CITY OF COLLEGE STATTZ)N
110.01 TE ,,AS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
`
----------------------------------------------------------------------------
Application Number .
. . . . 07-00000420 Date 2/22/07
Property Address . .
. . . . 5218 CASCADES DR
Property ID:
497900-0946-0100
R #:
R
Application type description
RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . .
. . . . PEBBLE CREEK
Property Use . . . .
. . . . RESIDENTIAL
Property Zoning . . .
. . . . SINGLE FAMILY RESIDENTIAL
Application valuation
. . . . 350000
Owner
Contractor
------------------------
------------------------
CLAY KOLBY HOMEBUILDING, LLP
P.O. BOX 8
NAVASOTA TX 77868
(979) 777-9840
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 3.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 3704.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 4.00
NUMBER OF BEDROOMS 4.00
SEWER TYPE PUBLIC
TAZ 419.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
KW
Permit Fee . . . .
1210.00 Plan Check Fee .00
Issue Date . . . .
2/22/07 Valuation . . . . 350000
Expiration Date . .
8/21/07
Qty Unit Charge
Per Extension
BASE FEE 460.00
250.00 3.0000
THOU BLDG, VAL 100001-500000 750.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS
THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS
OPENING (MINIMUM ROUGH FRAMED SIZE 22"
-------------------------------------------- ---- ------- -------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 2
Application Number 07-00000420 Date 2/22/07
----------------------------------------------------------------------------
Special Notes and Comments
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
Garage ceiling must have 5/8" Type X sheetrock when there
is Habitable space above the garage.
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
------------------------------------------------ I ------ X* ------
BUILDING DEPT REPRESENTATIVE:
APPLICANT: ( ��/
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page 3
Application Number . . . . . 07-00000420 Date 2/22/07
----------------------------------------------------------------------------
Special Notes and Comments
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
---- ---------------- ----------- ----IV -- -- - --'-------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page
4
Application Number 07-00000420 Date
2/22/07
----------------------------------------------------------------------------
Special Notes and Comments
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
STAIRS SHALL COMPLY WITH SECTION R-311 (2003 IRC) WITH A
CONTINUOUS HANDRAIL OR SECTION
1009 (2003 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL
NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A
NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND
LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003
IRC)
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
Be aware that front left corner of house is shown to be on
setback line make sure of proper placement.
Narrow wall bracing Fully Sheathed with APA Framing per
plans.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------------------------------
-----------------
Permit Fee Total 1210.00 1210.00 .00
.00
Plan Check Total .00 .00 .00
.00
Other Fee Total 750.00 750.00 .00
.00
Grand Total 1960.00 1960.00 .00
.00
-�
- ---------
-------------------------------- -----
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
11Q1 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
07-00000422 Date
2/22/07
Property Address
. . . . . .
5218 CASCADES DR
Property ID:
497900-0946-0100
R #:
R
Application type
description
TEMP POLE
Subdivision Name
. . . . . .
PEBBLE CREEK
Property Use . .
. . . . . .
RESIDENTIAL
Property Zoning .
. . . . . .
SINGLE FAMILY RESIDENTIAL
Application valuation
. . . .
0
Owner
Contractor
------------------------
------------------------
CLAY KOLBY HOMEBUILDING,
LLP
P.O. BOX 8
NAVASOTA TX
77868
(979) 777-9840
----------------------------------------------------------------------------
Permit . . . . .
. TEMP POLE
PERMIT
Additional desc .
. KW
Permit Fee . . .
. 20.00
Issue Date . . .
. 2/22/07
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
TEMP ELECT POLE CONNECT 45.00
----------------------------------------------------------------------------
Fee summary
Charged
----------
Paid Credited Due
------------------------------
-----------------
Permit Fee Total
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
--------------------------------- ----- - - ----- --------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
Energy Code Compliance Information
% Glazing
of exterior walls
/
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
3y
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor
R value of ductwork
_%
v l
A/C SEER rating
F-------------
| ^
\ --_-_-_--_
7close
/
-- -------- _----_---_----_- /
Lot|OPlock 49%5«9-D
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# DATE:
BUILDING ADDRESS: SZ l e CASca-d e
I. Foundation Requirements
NA/
A. Concrete minimum fc of 3000 PSI
B. Minimum four 4 inch slab thickness
C. Vapor barrier 6 mil. Poly min.
D. Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior unless over 60' Ion
3. Spacing of beams does not exceed 15'
E. Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F. Wood foundation details indicated
OK
II. Framing: Floor, Wall, Ceiling and Roof Requirements
NA/
A. Girder or sill dimensions, grade & species
B. Floor joist size, spacing, grade & direction of span indicted on plans
C. Treated sill plate or bottom plate
D. Tenant separation in duplex
K
1. One -hour rated extending to roof deck
OK
E. Header sizes indicated on plans
F. Emergency bedroom egress
1. Exit direct to outside
2. O enable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G. O enable bathroom window required when mechanical ventilation is not provided
H. Stud grade andspacing
I. Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J. Roof framing Ian or elevation shown
K. Ceiling joist size, spacing, grade and direction of span indicated on plans
L. Attic access location and size indicated on plans
M. Span exceeding code tables must be engineered
N. Rafter size and spacing and purlin bracing indicated.
O. Roof covering used.
P. Indicate Wall Bracing Used for Lateral Bracing
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
II. Framing: Floor, Wall, Ceiling and Roof Requirements continued
NA/
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
S. 18" Overhang allowed on zero lot line construction, perforated soffit allowed.
T. Protected openings on walls < three feet from property line
OK
N
III. Stairway Requirements
N
A. Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" diff. max.
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches above handrail
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located four or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four (4) inch sphere
IV. Fireplace Requirements to be indicated onplans)
N O
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must extend at least three (3) feet higher than the highest point where it
projects through the roof of a building & at least two (2) feet higher than any portion of the
building within ten (10) feet horizontal
. PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
V. Electrical Service Requirements
N K
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
VI. Plumbing Requirements
NMOW
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
NAft
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
NA/
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N K
Maximum drive width for residence is 25' combined for circular 12' minimum
Minimum 20 feet from driveway to side(intersecting) street
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
NA/
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
N
Does not block any water course or divert any flow
Elevation certificate needed
NAOK
v
,j6"- a
y �-I von
PLANS EXAMINER DATE
"APPROVED PLANS PER IRC SECTION R106.3.1."
REScheck Compliance Certificate
2000 IECC
REScheck So$ware Version 3.6 Release la
Data filename: C:\Program Files\Check\REScheck\Job 138.rck
SZI 9
PROJECT TITLE: MM Cascades
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
WINDOW / WALL RATIO: 0.14
DATE: 02/ 14/07
DATE OF PLANS: 2/14/2007
PROJECT DESCRIPTION:
Job 138
DESIGNER/CONTRACTOR:
Clay Kolby Homebuilding
COMPLIANCE: Passes
Maximum UA = 942
Your Home UA = 567
39.8% Better Than Code (UA)
Maximum SHGC = 0.40
Your SHGC = 0.27
Ceiling 1: Flat Ceiling or Scissor Truss
Ceiling 2: Cathedral Ceiling (no attic)
Wall 1: Wood Frame, 16" o.c.
Window 1: Vinyl Frame:Double Pane with Low-E
SHGC: 0.27
Door l: Solid
Door 2: Glass
SHGC: 0.30
Furnace 1: Forced Hot Air, 78 AFUE
Air Conditioner 1: Electric Central Air, 14 SEER
Permit Number
Checked By/Date
Gross
Glazing
Area or
Cavity
Cont.
or Door
Perimeter
R-Value
R-Value
U--Facto
UA
3534
0.0
30.0
110
170
19.0
0.0
9
3350
13.0
0.0
231
436
0.390
170
54
0.300
16
48
0.640
31
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans,
specifications, and other calculations submitted with the permit application. The proposed building has been designed to
i
meet the 2000 IECC requirements in REScheck Version 3.6 Release la (formerly MECcheck) and to comply with the
mandatory requirements listed in the
/REScheck Inspection Checklist.
Builder/Designer Date
REScheck Inspection Checklist
2000 IECC
RES check S ollware Version 3.6 Release la
DATE: 02/ 14/07
PROJECT TITLE: 5220 Cascades
Bldg.
Dept.
Use
[ ]
[ ]
[ ]
[ l
Ceilings:
1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 continuous insulation
Comments:
2. Ceiling 2: Cathedral Ceiling (no attic), R-19.0 cavity insulation
Comments:
Above -Grade Walls:
1. Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation
Comments:
Windows:
1. Window 1: Vinyl Frame:Double Pane with Low-E, U-fictor- 0.390
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [ ] Yes [ ] No
Comments:
Doors:
1. Door 1: Solid, U-factor: 0.300
Comments:
2. Door 2: Glass, U-factor: 0.640
Comments:
Heating and Cooling Equipment:
1. Furnace 1: Forced Hot Air, 78 AFUE or higher
Make and Model Number
2. Air Conditioner 1: Electric Central Air, 14 SEER or higher
Make and Model Number
Solar Heat Gain Coefficient:
The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC
values must be determined in accordance with the NFRC test procedure or taken from the default table.
Air Leakage:
Joints, penetrations, and all other such openings in the building envelope that are sources of air
leakage must be sealed.
Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly
with a 0.5" clearance from combustible materials. Ifnon-IC rated, the fixture must be installed with a
3" clearance from insulation.
Materials Identification:
Materials and equipment must be installed in accordance with the manuficturei's installation instructions.
Materials and equipment must be identified so that compliance can be determined.
Manufacturer manuals for all installed heating and cooling equipment and service water heating
equipment must be provided.
Insulation R-values, glazing U-factors, and cooling equipment efficiency must be clearly marked on
the building plans or specifications.
Duct Insulation:
Ducts in unconditioned spaces must be insulated to R-5.
Ducts outside the building must be insulated to R-8.0.
Duct Construction:
All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives),
mastic -plus -embedded -fabric, or tapes. Tapes and mastics must be rated UL 181A or UL 181B.
Exception: Continuously welded and locking -type longitudinal joints and seams on ducts
operating at less than 2 in. w.g. (500 Pa).
The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
Thermostats are required fDr each separate HVAC system. A manual or automatic means to
partially restrict or shut offthe heating and/or cooling input to each zone or floor shall be provided.
Service Water Heating:
Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the
water heater has an integral heat trap or is part of circulating system.
Insulate circulating hot water pipes to the levels in Table.1.
Circulating Hot Water Systems:
Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
[ ] All heated swimming pools must have an on/offheater switch and require a cover unless over 20%
ofthe heating energy is from non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
[ ] HVAC piping conveying fluids above 105 T or chilled fluids below 55 °F must be insulated to the
levels in Table 2.
Table l: Minimum Insulation Thickness for Circulating Hot Water Pipes.
Insulation Thickness in Inches by Pie Sizes
Heated Water Non -Circulating Runouts Circulating Mains and Runouts
Temperature (Fl LID to 1" Up to 1.25" 1.5" to 2.0" Over 2"
170-180 0.5 1.0 1.5 2.0
140-160 0.5 0.5 1.0 1.5
100-130 0.5 0.5 0.5 1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes.
Fluid Temp.
( F)
Insulation
Thickness
in Inches by Pine
Sizes
2" "
Runouts
1"
Less 1.25"
Pining System Types
Heating Systems
Range
2"
and
to
Low Pressure/Temperature
201-250
1.0
1.5
1.5
2.0
Low Temperature
120-200
0.5
1.0
1.0
1.5
Steam Condensate (fDr lead water)
Any
1.0
1.0
1.5
2.0
Cooling Systems
Chilled Water, Refrigerant,
40-55
0.5
0.5
0.75
1.0
and Brine
Below 40
1.0
1.0
1.5
1.5
NOTES TO FIELD (Building Department Use Only)
0