Loading...
HomeMy WebLinkAboutRES2007-00418Inspection Results Entry - City of College Station Home] Hew 1Nind"v I Support Inspection Results Entry Email I I Help Application number, type: 07 00000418 RESIDENTIAL, 1 UNIT DETACHED NEW Structure, permit: 000 000 BLDG 00 Inspection type, sequence: 8125 0001 BLDG, FINAL Property address: 3803 BRIDLE CT Request date, time, by: 8/07107 17:00 KW Inspector ID: 10C ► Results date: 0M712007 Results status: Final inspection flag: v ► Point value: r 1 �C Uf� lvim ` (8/8/2007) Kim Wolfe - Re: Calling for CO @ 3803 Bridle Ct� Page 1?' From: Terry Boriskie To: Amber Carter; Benjamin McCarty; Chris Haver; Gina Southerland; Joe G... Date: 8/8/2007 1:54 PM Subject: Re: Calling for CO @ 3803 Bridle Ct Contacted Charles Johnson at 224-3000 and will raise box. Terry Boriskie City of College Station Residential Plans Examiner 979-764-3744 >>> Paul Schoenfeld 8/7/2007 3:42 pm >>> Water ok. Sewer needs to be raised. Paul >>> Kim Wolfe 8/7/2007 11:57 AM >>> any issues? BP # 07-418 Thanks Kimberly Wolfe, CPS/CAP City of College Station Planning & Development Services (979) 764-3570 www.csbc.aov TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 11Q1 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 07-00000515 Date 2/27/07 Property Address . . . . . . 3803 BRIDLE CT Property ID: 159010-0201-0090 Application type description TEMP POLE Subdivision Name . . . . . . BRIDLE GATE ESTATES PH 2 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 0 Owner Contractor ------------------------ OAKWOOD CUSTOM HOMES GROUP LTD ------------------------ CROSS CREEK HOMES AND DEVEL 4012 SH 6 S 12200 WICKSON LAKE RD COLLEGE STATION TX 77845 BRYAN TX 77808 (979) 589-3546 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . NC Permit Fee . . . . 20.00 Issue Date . . . . 2/27/07 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary Charged ---------- Paid Credited ------------------------------ Due ----------------- Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 ------------------- BUILDING DE APPLICANT: WFO877428 / 001 City of College Station PAGE 1 REQ. DATE: 02/27/07 02/27/07 16:17:22 LOCATION: 3803 BRIDLE CT LOC ID: 200596 REQUESTOR: CROSS CREEK HOMES AND DEVEL ORIGIN: CUSTOMER -WALK IN REQ USER: NCOCHRAN AUTH USER:NCOCHRAN WRK TYPE: TEMP POLE PASSED ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 02/27/07 SCHED COMPLETION: 02/27/07 ******************************************************************************** JOB ORDER RESULT COMMENTS WFO876056 / 001 City of College Station c L a PAGE 1 REQ. DATE: 02/22/07 02/22/07 9:35:52 LOCATION: 3803 BRIDLE CT LOC ID: 200596 REQUESTOR: CROSS CREEK HOMES & DEV ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT 4" SWR TAP 3/4" WTR TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 02/22/07 SCHED COMPLETION: 02/22/07 ******************************************************************************** JOB ORDER RESULT COM4K TTS City of College Station 1101 TEXAS AVENUE COLLEGE STATION TX 77840 C E R T I F I C A T E O F O C C U P A N C Y P E R M A N E N T Issue Date . . . . . . Parcel Number . . . . . Property Address . . . Subdivision Name . . . Legal Description . . . Property Zoning 8/09/07 159010-0201-0090 3803 BRIDLE CT COLLEGE STATION TX 77845 BRIDLE GATE ESTATES PH 2 BRIDLE GATE ESTATES #2, SECTIO N 2, BLOCK 1, LOT 9 SINGLE FAMILY RESIDENTIAL Owner . . . . . . . . . OAKWOOD CUSTOM HOMES GROUP LTD Contractor . . . . . . Application number Description of Work Construction type . . . Occupancy type . . . . Flood Zone . . . . . . Approved . . . . . . . CROSS CREEK HOMES AND DEVEL 979 589-3546 07-00000418 000 000 RESIDENTIAL, 1 UNIT DETACHED NEW COMBUSTIBLE (UNPROTECTED) RESIDENTIAL-SFR/DUPLEX Building Official VOID UNLESS SIGNED BY BUILDING OFFICIAL W ,- ;D l W)vI a 42'220'201'2711 c BRIDALGATE LOT-9 BLOCK - 1 sr�ET A--6 �' svt LEf- BLoaouf 1-2*W BRAD JOHNSON 281-543-2045 JOB# 07-007(2233) PLAN# 1726 ® � tip DEgfQNS, �I.NC. (877) 690-CADD 4500 Carter Creek Dr. #203 Bryan, TX 77802 wwwxaidesigns.com 1TR - R PAIdMXHMUS 1-26 07 txr1 -�rlsxoUr 1_29..� DATE: O1-29-07' BUILDING PERMIT CITY OF COLLEGE STATION 11 d1 TEAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 07-00000418 Date 2/22/07 Property Address . . . . . . 3803 BRIDLE CT Property ID: 159010-0201-0090 R #: R300289 Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . BRIDLE GATE ESTATES PH 2 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 114400 Owner Contractor ---------- - ------------- OAKWOOD CUSTOM HOMES ------------------------ GROUP LTD CROSS CREEK HOMES AND DEVEL 4012 SH 6 S 12200 WICKSON LAKE RD COLLEGE STATION TX 77845 BRYAN TX 77808 (979) 589-3546 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1726.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC TAZ 405.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . Permit Fee . . . . 505.00 Plan Check Fee .00 Issue Date . . . . 2/22/07 Valuation . . . . 114400 Expiration Date . . 8/21/07 Qty Unit Charge Per Extension BASE FEE 460.00 15.00 3.0000 THOU BLDG, VAL 100001-500000 45.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" ------------------- BUILDING DE APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 07-00000418 Page 2 Date 2/22/07 Special Notes and Comments X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12' ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ----------------------------*�Tr --------------- ------ -------:---------- Z.Z- BUILDING DEPT REP APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 07-00000418 Page 3 Date 2/22/07 Special Notes and Comments ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE For residential applications with a glazing area that exceeds 150 of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN -------------------------------- --------------- ------ ---- -------------- BUILDING DEPT REPRES -09 APPLICANT: - BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 4 Application Number . . . . . 07-00000418 Date 2/22/07 ---------------------------------------------------------------------------- Special Notes and Comments ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND CLOTHES DRYERS. Be aware of Bay Window Breakfast Area is right on rear 20, setback line. Narrow Wall Bracing Fully Sheathed with APA Garage framing and Living Room area per plans. Move front door up to within 4' of bedroom #2 wall with 34" minimum OSB. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ---------------------------------------- ----------------- Permit Fee Total 505.00 505.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1255.00 1255.00 .00 .00 ------------------------- ------ - A --- ------------- BUILDING--DEPT-----RE--P,�--ESE- --- ------- Dd'!) ./� APPLICATION FOR BUILDING PERMIT 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX CITY OF COLLEGE STATION WWW.CSTX.GOV Planning. & Dev lepmenl Seivicer or Office URC y DATE: �2 �TQ APPLICATION # M " 1 `� TEMP POLE # ADDRESS/LOCATION: 63 XD o o LOT _T BLOCK ��SUBDIVISION Rj!dLE �i� �fi'iP'9.ES SEC/PH �� BUSINESS/OWNER NAME: a�C,{tLs�i+Cf�oiy��ffji,Ej/��i *�i. Ji +E ,(.CO JPHONE: 999 GRACTOR/HOMEOWNER: PHONE: 9?4-s�'9-35`iG RACTORADDRESS: /oZo?OD [�/rd�sa-lLr14K,E� R&.J. %X '7,7,?d.f C. RICIAN: &E.J KzBsa,4 PLUMBER: eA tadyE- F /A . o6w A60'zzwe5z GOOD CENTS (Residential only): CLASS OF WORK CCESSORY/STORAGE LOCATION RE -ROOF DDITION MOVING SHELL ONLY EMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ONLY UPLEX (Landscape Plans) REMODEL/RENOVATION* SWIMMING POOL TENT/CANOPY DESCRIPTION OF WORK: �Es1yE./r�.4L �Ft-✓ LtaRuGT1o�l PROPOSED USE: lgCSLX E T1.9fL wHOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: �D 1 TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT � 1VALUATION: $ /AKAnd ✓ REGISTRATION# EABPRJ TOTAL AREA: �13 HEATED AREA: /7 SF (Cost 6f Labor and Materials) PUBLIC SEWER NUMBER OF BEDROOMS: 3 SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS:_ SEWER TAP: A/ INTERIOR WALL TYPE: Sff�ETROC SIZE LAJ WATER TAP: -3y /I _ EXTERIOR WALL TYPE: C zW Ofd E5*,"W,9 SIZE OTHER TAP: FOUNDATION TYPE: SLAB SIZE TEMP POLE ROOF TYPE: L�oM�OsY7lo.i GARAGE TYPE: SINGLE DOUBLE TRIPLE ATTACHED ffL DE);Ao§p,, CARPORT a SIGNATURE OF APPLICANT: *If proposed work involves new co merclali commercial property, building elevations are i Plans Examiner ✓g ke.1k4l's t 9 zk or facade improvements/renovations to an existing wired. Official Use Only Zoning Official gD.mme YES or NO M Gy. k4 A60- w1'40WY Fire Marshall NCB r Enggy Cgde Compliance Information % Glazing of exterior walls /o Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) 3 O Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC • �%V Glazing U-Factor • G.S� R value of ductwork Cp A/C SEER Rating 3 9 0 4 FA PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# 0 r7 ` `, I / � DATE: ) _ ZO , 0? BUILDING ADDRESS: � 3So3 132J1e C4 . I. Foundation Requirements N K A. Concrete minimum fc of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier 6 mil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior unless over 60' Ion 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated K II. Framing: Floor, Wall, Ceiling and Roof Requirements A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex OK 1. One -hour rated extending to roof deck OK E. Header sizes indicated on plans F. Emergency bedroom egress 1. Exit direct to outside 2. O enable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. O enable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Exterior wall covering indicated on plans 2. Sheathing indicated on plans 3. Moisture barrier indicated on plans J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans M. N. O. P. Span exceeding code tables must be engineered Rafter size and spacing and purlin bracing indicated. Roof covering used. Indicate Wall Bracing Used for Lateral Bracing PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX II. Framing: Floor, Wall, Ceiling and Roof Requirements continued NA/ P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations S. 18" Overhang allowed on zero lot line construction, perforated soffit allowed. T. Protected openings on walls < three feet from property line AqAJ10K III. Stairway Requirements tWOK A. Stairway Details 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" diff. max. 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8 B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches above handrail 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located four or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four (4) inch sphere IV. Fireplace Requirements (to be indicated onplans) OK A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must extend at least three (3) feet higher than the highest point where it projects through the roof of a building & at least two (2) feet higher than any portion of the building within ten (10) feet horizontal PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX V. Electrical Service Requirements NA/OK) A. Electrical plan to include: 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location VI. Plumbing Requirements NAIM A. Pressure reducing valve required when water pressure exceeds 80 psi B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N O14 A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) Vill. Energy Requirements N A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 N Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements N Maximum drive width for residence is 25' combined for circular 12' minimum Minimum 20 feet from driveway to side(intersecting) street Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 NAfto Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 N O Does not block any water course or divert any flow Elevation certificate needed OK JL* L - r Z.a--D PLANS EXAMINER DATE "APPROVED PLANS PER IRC SECTION R106.3.1." REScheck Compliance Certificate 2000 IECC REScheckSoBware Version 3.5 Release lb Data filename: C:\RANobs\07-007 Johnson\Correspondence\07-007.rck TITLE: 1726 Sq Ft Plan CITY: Bryan (Brazos County) STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 01/30/07 DATE OF PLANS: 01-29-07 COMPANY INFORMATION: John Rhodes R.A.I. Designs, Inc. 979-846-3366 COMPLIANCE: Passes Maximum UA = 665 Your Home UA = 632 5.0% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.40 Ceiling 1: Flat Ceiling or Scissor Truss Ceiling 2: Cathedral Ceiling (no attic) Wall l: Wood Frame, 16" o.c. Window 1: Metal Frame:Double Pane with Low-E SHGC: 0.40 Door 1: Solid Door 2: Glass SHGC: 0.40 Floor 1: Slab-On-Grade:Unheated Insulation depth: 0.0' Permit Number Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Vahie U-Factor UA 1599 30.0 0.0 56 127 13.0 0.0 9 1965 13.0 0.0 124 300 0.650 195 38 0.550 21 18 0.650 12 ' 206 0.0 215 COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in RES checkVersion 3.5 Release lb (formerly MECchec,§ and to comply with the mandatory requirements listed in the RES checklnspectioAhWist.. A _ Builder/Designer V v Date �� - Area Calculator: Add to Library Window Name Assembly Type Quantity Width x Height = Unit Area Total Area U-Factor SHGC Comments/ Description 1 5060 Metal Frame, Do 2 5'-0" 6'-0" 30.00 60.00 ft2 0.650 0.400 2 15028 RT Metal Frame, Do 2 D = 2'-6" 2.45 4.90 ft2 3 3060 Metal Frame, Do 2 T-0" 1 6'-0" 18.00 36.00 ft2 0.650 0.400 4 4040 Metal Frame, Do 1 41-0" 4'-0" 16.00 16.00 ft2 0.650 0.400 5 3050 Metal Frame, Do 7 T-V' 5'-0" 15.00 105.00 ft2 0.650 0.400 6 4060 Metal Frame, Do 2 4'-0" 6'-0" 24.00 46.00 ft2 0.650 0.400 7 3030 Metal Frame, Do 2 3'-0" T-0" 9.00 16.00 ft2 0.650 0.400 8 13014 Metal Frame, Do 3 T-0" 1'4" 4.00 12.00 ft2 0.650 0.400 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 P24 25 Window Area Total: 299.90 01/30/07 09:12:30 1/1 Area Calculator: Description' Door Area Total: 55.56 1/1 Area Calculator: �■�■�� Ceiling Area Total: 1726.00 111 Area Calculator: I I ,.. -&k I -I .j-;- ,. I - Ama I I Comments/Description Exterior Wall Area Total: 1885.25 111 Area Calculator: IN: Assembly .: Comments/Description EM ® ■�■■■�■■��■� Floor Area Total: 0.00 01/30/07 09:12:31 1/1