HomeMy WebLinkAboutRMDL2007-00415BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 07-00000415 Date 2/26/07
Property Address . . . . . . 9207 WHITNEY CT
Property ID: 668700-1034-0110
R #: R104885
Tenant nbr, name . . . . . . FOUNDATION REPAIR
Application type description RESIDENTIAL, REMODEL & RENOVATION
Subdivision Name . . . . . . WOODCREEK #10
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 25150
Owner Contractor
------------------------ ------------------------
SMITH, EUGENE B & ALTHA H DAWSON FOUNDATION REPAIR
9207 WHITNEY CT 6906 CHETWOOD
COLLEGE STATION TX 778458787 HOUSTON TX 77081
(713) 668-2110
--- Structure Information 000 000 REPAIR PIERS
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info . . . . . IMPACT/PRORATA FEES PAID NA
HEATED AREA 1.00
INTERIOR WALL TYPE NA
NUMBER OF BATHROOMS 1.00
NUMBER OF BEDROOMS 1.00
SEWER TYPE PUBLIC
TAZ 365.00
---------------------------------------------------------------------- - - - - -
-
Permit . . . . . . BUILDING PERMIT
Additional desc . . NC
Permit Fee . . . . 140.00 Plan Check Fee .00
Issue Date . . . . 2/26/07 Valuation . . . . 25150
Expiration Date . . 8/25/07
Qty Unit Charge Per Extension
BASE FEE 15.00
25.00 5.0000 THOU BLDG, VAL 1001-50000 125.00
----------------------------------------------------------------------------
Special Notes and Comments
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
----------------- - - --------------------
--------------
BUILDING DE 2LL_4t_"'_N
EPRESENTATIVE:
APPLICANT: ���
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page 2
Application Number . . . . . 07-00000415 Date 2/26/07
----------------------------------------------------------------------------
Special Notes and Comments
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
Placing 64 both interior and exterior repair piers.
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
---------------------------------------------------------
Permit Fee Total 140.00 140.00 .00 .00
Plan Check Total .00 .00 .00 .00
Grand Total 140.00 140.00 .00 .00
--------------------------- - -- ----------------------
BUILDING DE REPRESENTATIVE:
APPLICANT:
FEB-19-2007 MON 04:52 PM DAWSON FOUNDATION REPAIR FAX NO. 7136688521 P. 01
z
m
m
v
V/
". APPLICATION FOR BUILDIN07 PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77844
CITY OF COLLEGE STArION (979) 764.3570 (979) 764-3496 FAX
P4vj**C*L1eet�OPhhalSn{y.!p
www.C6TX.G0v
ADDRESS/LOCATION:-Z rU * VWJ h I r- 1(\ Q L
01, 1wao...an
DATE;
APPLICATION #
TEMP POLE i
LOT BLOCK SUBDIVISION r SEC/PH
BUSINESS/OWNER NAME: C qz pH04,1 9
CONTRACTOR/HOMEOWNER:-bauji . roo- �y143 oL
CONTRACTOR ADDRESS: A.0 - l 0(b O-A\ QA U. I. _ t- f \ ` v' , n'O/
ELECTRICIAN:
PLUMBER:
GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY 1�
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION " LA13 ONLY
DUPLEX (Landscape Plans REMODEL/RENOVATION- SWIMMING POOL Y
Q Required)
DESCRIPTION OF WORK: Wk r-) _�
Z .w� tJ .� 1 1 ► 1 1 I it I
HVAC:
�STRUCTURE USE:
rok?5
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL;
�p�
�`' 1TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ TOTAL AREA; HEAT!*D AREA:
( of rand at.
Is)
❑ PUBLIC SEWER
❑ SEPTIC/TREATMENT SYSTEM
❑ SEWER TAP:
Size
❑ WATER TAP:
SIZE _
OTHER TAP:
❑ TEMP POLL=
GARAGE TYPE:
SIZE
SINGLE ❑
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS:
INTERIOR WALL, TYPE:
EXTERIOR WALL, TYPE:
FOUNDATION TtPE:
ROOF TYPE:
DOUBLE TRIPLE ❑
(ETAS ED ❑ ,:,ARPORT
SIGNATURE OF APPLICANT: Ir " V 2
*!f proposed work involves new mar'tial cons on or faca'�e improvements/renovations to an exisi
Commercial property, building elevations are req ' .
n Official Use Only
2, fl C ants:
NO
Plans Examiner _ Zoning trial
T
may, P 1 aa
FEB-19-2007 MON 04:52 PM DAWSON FOUNDATION REPAIR FAX NO. 7136688521 P. 02
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted ar
Glazing SHGC
Glazing U-Factor
R value of ductwork
AJC SEER Rating
attic)
L
40
FEB-19-2007 MON 04:52 PM DAWSON FOUNDATION REPAIR
PIER LOCATION
PIER LOCATION OPTION 2
X = EXISTING PIERS
FTI = PIERS TO BE REJACKED
HYDROSTATIC TEST U PRE -TEST P(POST-TEST Q NO -TES]
FAX NO. 7136688521
P. 03
ADDRESS 920-1 WN CWglr
CONTACT F-agignia sm
PHONE NO.
I o", nAr s mwov, W.
FFoundation Repair
V BktAK-OUTS
GARAGE ATTACHED
GARAGE DFrACH'ED 6906 Chetwood - Houston, Texas 77081 - (713) 66&2110 Fax 66&UZI
FEB-19-2007 MON 04:53 PM DAWSON FOUNDATION REPAIR FAX N0, 7136688521
Y.latJiPLE PIER DIAGRAM O.� �Q� W �
CROSS SECTION
C�)NCRkT'E BLOCKS
I
STEEL SHIMS ---�
TWO 8" x 8" x 12" SOLID --�
CONCRETE BLOCKS
TOP VIEW I 3'6d APPROX
CONCRETE
BLOCK
PLACEMENT
9" DIAMETER
SHAFT
22" DIAMETER
BELT.
CAP SECTION
REBAR
MAT
LACEMENT
DAWfO N
6906 Chetwood • Houston, Texas 77081
(713) 668-2110 Fax (713) 668-8521
i THREE PIECES
1/2" STEEL REBAR
92 REBAR TIES
FRONT VIEW
GRAQeBEAM
3"
P. 04
t .
12"
4
TWOim" I
STEEL. REBAR
MATS 12'
22' ----lp
SELL BOTTOM
9' DIAMETER i
SHAFT
ALL PIERS POURED WITH 5 SACK CONCRETE.
NOTE: DEPTH OF PIER MAY VARY ACCORDING TO
LOCATION OF STABLE LOAD -SEARING CLAY.
(EIGHT FOOT MINIMUM DEPTH)