HomeMy WebLinkAboutRES2007-00411, 07-412F
0
PREPARED 8/13/07, 8:48:16
INSPECTION TICKET
PAGE 1
City of
------------------------------------------------------------------------------------------------
College Station
INSPECTOR: BUILDING INSPECTOR
DATE 8/13/07
ADDRESS
3714 BRIDLE CT
SUBDIV: BRIDLE GATE ESTATES
PH 2
CONTRACTOR GEMSTAR HOMES & CONSTRUCTION PHONE (956) 592-5181
OWNER
OAKWOOD CUSTOM HOMES GROUP LTD PHONE
PARCEL
159010-0202-0360
APPL NUMBER: 07-00000411 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT:
BLDG 00 BUILDING PERMIT
REQUESTED INSP
DESCRIPTION
TYP/SQ
COMPLETED RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01
3/13/07 JGM
BLDG, FOUNDATION -SLAB TIME: 17:00
3/13/07 AP
March 13, 2007 8:16:55 AM ncochran.
Strings On Setbacks O.K.
Slab Ground Installed
B115 01
5/07/07 OC
BLDG, FRAMING TIME: 17:00
5/07/07 AP
May 7, 2007 8:38:20 AM kwolfe.
B130 01
5/08/07 OC
BLDG, INSULATION TIME: 17:00
5/08/07 AP
May 8, 2007 1:49:23 PM glsouth.
May 8, 2007 4:58:00 PM kwolfe.
B125 tl
3/p7
BLDG, FINAL TIME: 17:00
Yv
.3 07 �� PAC'
August 13, 2007 8:47:53 AM glsouth.
--------------------------------------
COMMENTS AND NOTES--------------------------------------
C(f Y)d 2,.(
'34
�c
T•
. No
(8/14/2 107) Kim Wolfe - Re: Calling for C.O. @ 3714 Bridle Ct. Page 1
From: Terry Boriskie
To: Amber Carter; Benjamin McCarty; Chris Haver; Gina Southerland; Joe G...
Date: 8/14/2007 10:14 AM
Subject: Re: Calling for C.O. @ 3714 Bridle Ct.
Contacted Ray Garza at 1-956-592-5181
Terry Boriskie
City of College Station
Residential Plans Examiner
979-764-3744
>>> Mitchell Carson 8/13/2007 12:31 pm >>>
SEWER BOX IS BURIED DID PLACE A GREEN FLAG AT THE SPOT MITCH
>>> Gina Southerland 8/13/2007 8:49 AM >>>
BP# 07-411 A
Gina Southerland
CSR - Planning & Development Services
City of College Station
979-764-3570
www.csbc.gov
WF0877952 / 001 City of College Station PAGE 1
REQ. DATE: 03/01/07 03/01/07 11:39:21
LOCATION: 3714 BRIDLE CT LOC ID: 200642
REQUESTOR: GEMSTAR HOMES & CONSTRUCTION ORIGIN: CUSTOMER -WALK IN
REQ USER: GLSOUTH AUTH USER:GLSOUTH WRK TYPE:
TEMP POLE PASSED
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 03/01/07 SCHED COMPLETION: 03/01/07
********************************************************************************
JOB ORDER RESULT COMMENTS ] �\
WF0875885 / 001 City of College.Son
PAGE 1
REQ. DATE:
02/21/07
02/21/07
16:54:36
LOCATION:
3714 BRIDLE CT
LOC ID:
200642
REQUESTOR:
GEMSTAR HOMES & CONSTRUCTION ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
GLSOUTH AUTH. USER: GLSOUTH
WORK TYPE:
ROUT
SWR 4"
WTR 3/4"
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT SET
READY
SCHED START:
02/21/07 SCHED COMPLETION:
02/21/07
JOB ORDER RESULT COM14ENrS
City of College Station
1101 TEXAS AVENUE
COLLET STATION TX 77840
T E M P O R A R Y C O
T E M P O R A R Y
Issue Date . . . . . .
Expiration Date . . . .
Parcel Number . . . . .
Property Address . . .
Subdivision Name . . .
Legal Description . . .
Property Zoning
8/14/07
8/28/07
159010-0202-0360
3714 BRIDLE CT
COLLEGE STATION TX 77845
BRIDLE GATE ESTATES PH 2
BRIDLE GATE ESTATES #2, SECTIO
N 2, BLOCK 2, LOT 36
SINGLE FAMILY RESIDENTIAL
Owner . . . . . . . . . OAKWOOD CUSTOM HOMES GROUP LTD
Contractor . . . . . . GEMSTAR HOMES & CONSTRUCTION
956 592-5181
Application number 07-00000411 000 000
Description of Work RESIDENTIAL, 1 UNIT DETACHED NEW
Construction type . . . COMBUSTIBLE (UNPROTECTED)
Occupancy type . . . . RESIDENTIAL-SFR/DUPLEX
Flood Zone . . . . . .
Special conditions . .
Driveway needs to be c
Approved . . . . .
Buil
ected.
Vcr Official
VOID UNLESS SIGNED BY BUILDING OFFICIAL
City of College Station
1101 TEXAS AVENUE
COLLEGE STATION TX 77840
T E M P O R A R Y C O
T E M P O R A R Y
Issue Date . . . . . . 8/14/07
Expiration Date . . . . 9/07/07
Parcel Number . .
Property Address
Subdivision Name
Legal Description
Property Zoning .
Owner . . . . . .
Contractor . . .
159010-0202-0360
3714 BRIDLE CT
COLLEGE STATION TX 77845
BRIDLE GATE ESTATES PH 2
BRID TE ESTATES #2, SECTIO
N IOC 2, LOT 36
UNKNOWN
. . OAK US TOM HOMES GROUP LTD
GEMSTAR HOMES & CONSTRUCTION
956 592-5181
Application number 07-00000411 000 000
Description of Work RESIDENTIAL, 1 UNIT DETACHED NEW
Construction type . . . COMBUSTIBLE (UNPROTECTED)
Occupancy type . . . . RESIDENTIAL-SFR/DUPLEX
Flood Zone . . . . . .
Special conditions . .
Driveway needs to be corrected.
Approved . . . . . . .
Building Official
VOID UNLESS SIGNED BY BUILDING OFFICIAL
BUILDING PERMIT
CITY OF C G8 STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 .. FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number .
. . . . 07-00000411 Date 2/21/07
Property Address . .
. . . . 3714 BRIDLE CT
Property ID:
159010-0202-0360
R #:
R300312
Application type description
RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . .
. . . . BRIDLE GATE ESTATES PH 2
Property Use . . . .
. . . . RESIDENTIAL
Property Zoning . . .
. . . . SINGLE FAMILY RESIDENTIAL
Application valuation
185600
Owner
Contractor
------------------------
OAKWOOD CUSTOM HOMES
------------------------
GROUP LTD GEMSTAR HOMES & CONSTRUCTION
4012 SH 6 S
2374 LA FERIA RD
COLLEGE STATION
TX 77845 BROWNSVILLE TX 78520
(956) 592-5181
--- Structure Information
000 000 SINGLE FAMILY
Construction Type
COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 2812.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 3.00
NUMBER OF BEDROOMS 4.00
SEWER TYPE PUBLIC
TAZ 405.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
GS
Permit Fee . . . .
718.00 Plan Check Fee .00
Issue Date . . . .
2/21/07 Valuation . . . . 185600
Expiration Date . .
8/20/07
Qty Unit Charge
Per Extension
BASE FEE 460.00
86.00 3.0000
THOU BLDG, VAL 100001-500000 258.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS
THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL
BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS
OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
BUILDING DEPT REP,RESENTA
VE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page 2
Application Number . . . . . 07-00000411 Date 2/21/07
----------------------------------------------------------------------------
Special Notes and Comments
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
------------------------------------------- ------ --- ----- --------------
BUILDING DEPT REP SENTAT E:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page 3
Application Number 07-00000411 Date 2/21/07
----------------------------------------------------------------------------
Special Notes and Comments
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
-------------------------------------------- ----- --- --•- --'------------
BUILDING DEPT RE , SENTA VE:
APPLICANT: .{iv
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page
4
Application Number 07-00000411 Date
2/21/07
----------------------------------------------------------------------------
Special Notes and Comments
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
Be aware of Bryan Electrical Easement diagonal across back
left corner of property.
Minimum Foundation Beam width is 14"
Narrow wall bracing Fully Sheathed with garage door moved
over to left to get 24" minimum at right return for regular
framing, if less than 24" then it must be APA framed.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------------------------------
-----------------
Permit Fee Total 718.00 718.00 .00
.00
Plan Check Total .00 .00 .00
.00
Other Fee Total 750.00 750.00 .00
.00
Grand Total 1468.00 1468.00 .00
.00
-------- ----
BUILDING DEPT REP ENTAT E:
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
------------------------------------------------------------------------- --
Application Number
07-00000412 Date
2/21/07
Property Address . . . . . .
3714 BRIDLE CT
Property ID:
159010-0202-0360
Application type description
TEMP POLE
Subdivision Name . . . . . .
BRIDLE GATE ESTATES PH 2
Property Use . . . . . . . .
RESIDENTIAL
Property Zoning . . . . . . .
SINGLE FAMILY RESIDENTIAL
Application valuation . . . .
0
Owner
Contractor
------------------------
OAKWOOD CUSTOM HOMES GROUP LTD
------------------------
GEMSTAR HOMES & CONSTRUCTION
4012 SH 6 S
2374 LA FERIA RD
COLLEGE STATION TX 77845
BROWNSVILLE
TX 78520
(956) 592-5181
----------------------------------------------------------------------------
Permit . . . . . . TEMP POLE
PERMIT
Additional desc . . GS
Permit Fee . . . . 20.00
Issue Date . . . . 2/21/07
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . . . . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary Charged
----------
Paid Credited
------------------------------
Due
-----------------
Permit Fee Total 20.00
20.00 .00
.00
Other Fee Total 45.00
45.00 .00
.00
Grand Total 65.00
65.00 .00
.00
------------------------------------------ ----d-1-------------
BUILDING DEPT RE�jSENTAT E:
APPLICANT:
ADDRESS/LOCATION
LOT LOCK
APPLICATION FOR BUILDING PERMIT
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
WWW.CSTX.GOV
1
CITY OF COLLEGE STATION
Planning.<S'.Dcvdo ii iiServrccr. tt ( /' / i �j /
7 f -6r l Q I e- C. 4• COY, 1 le G �o�ti�cSYl_�X_ %-7 1f Ll ✓
/ C� -/ SEC/PH Z SUBDIVISION �d\� a��
For ONke Use Only
DATIA144.M. RCCREG
APPLICATION #
TEMP POLE #
BUSINESS/OWNER NAME: Wc,K &maw ,- -ov► v �rh,PHONE: 95b— 59� -SJ JP!
CONTRACTOR/HOMEOWNER: 64VF-zA PHONE:
JTRACTORADDRESS: a37L) L A Feria PeJ. ,raw�s�;�« P 74.
CTRICIAN: 49AS ' ( Gc -�r i L PLUMBER
�C: GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) 7,NEW CONSTRUCTION * SLAB ONLY
DUPLEX (Landscape Plans) REMODEL/RENOVATION" SWIMMING POOL
TENT/CANOPY
DESCRIPTION OF WORK: I-3o l\A i�.s ox View V-evriz.
PROPOSED USE: L-ivi nq ,
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $
(Cost of Labcfrand /aterS � s9�
PUBLIC SEWER
` SEPTIC/TREATMENT SYSTEM
ff
dSEWER TAP:
S - � IS IZ p
dATERWTAP: N
SIZE
OTHER TAP:
J TEMP POLE
Q GARAGE TYPE:
SIZE
SINGLE
ATTACHED 1W
TOTAL AREA: 3, (a58 HEATED AREA: g )
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE
EXTERIOR WALL TYPE
FOUNDATION TYPE
ROOF TYPE:
DOUBLE EZ
q
3 /�z
�'✓ l L k- �/ rz 6'1-E-e r
SInb
TRIPLE
"AIRPORT ED
SIGNATURE OF APPLICANT:
*If proposed work involves new commerci onstructi r facade improvements/renovations to an existing
commercial property, building elevations are require .
Official Use Only
Plans Examiner Zoning Official
Awa yt.,� D * 5) ee,4ju,.j
a�1�ss L4 ),e'C+ Pw'w' CA- C ments:
✓ N4 w/�` w�►^W- p ol al .` &I., or NO
Fire Marshall
01
•
r
�
Enemy Godef Compliance Information
% Glazing of exterior. walls 0
Insulation R value of exterior walls 13 ✓
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic) 9
Glazing SHGC . q'
Glazing U-Factor 7 S /
R value of ductwork
A/C SEER Rating 3 ./
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# 01141
11_1 DATE:
BUILDING ADDRESS: 39
14 �Rlre &. -
I. Foundation Requirements
NA/
A. Concrete minimum fc of 3000 PSI
B. Minimum four 4 inch slab thickness
C. Vapor barrier 6 mil. Poly min.
D. Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior unless over 60' Ion
3. Spacing of beams does not exceed 15'
E. Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F. Wood foundation details indicated
II. Framing: Floor, Wall, Ceiling and Roof Requirements
NA/
A. Girder or sill dimensions, grade & species
B. Floor joist size, spacing, grade & direction of span indicted on plans
C. Treated sill plate or bottom plate
D. Tenant separation in duplex
K
1. One -hour rated extending to roof deck
OK
E. Header sizes indicated on plans
F. Emergency bedroom egress
1. Exit direct to outside
2. O enable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G. O enable bathroom window required when mechanical ventilation is not provided
H. Stud grade andspacing
I. Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J. Roof framing Ian or elevation shown
K. Ceiling joist size, spacing, grade and direction of span indicated on plans
L. Attic access location and size indicated on plans
M. Span exceeding code tables must be engineered
N. Rafter size and spacing and purlin bracing indicated.
O. Roof covering used.
P. Indicate Wall Bracing Used for Lateral Bracing
J
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
II. Framing:
Floor, Wall, Ceiling and Roof Requirements continued
N
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
S.
T.
18" Overhang allowed on zero lot line construction, perforated soffit allowed.
Protected openings on walls < three feet from property line
III. Stairway Requirements
OK
A.
Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" diff. max.
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B.
Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C.
Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches above handrail
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D.
Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located four or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four (4) inch sphere
IV. Fireplace Requirements (to be indicated onplans)
K
A.
Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B.
Masonry fireplace requires 2" clearance from all combustible materials
C.
Chimneys must extend at least three (3) feet higher than the highest point where it
projects through the roof of a building & at least two (2) feet higher than any portion of the
building within ten (10) feet horizontal
b
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
V. Electrical Service Requirements
N
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
VI. Plumbing Requirements
NAJOYI
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units)
T
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
Vill. Energy Requirements
N K
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window LI-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N K
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N
Maximum drive width for residence is 25' combined for circular 12' minimum
Minimum 20 feet from driveway to side(intersecting) street
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
NA/
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
N
Does not block any water course or divert any flow
Elevation certificate, needed
OK
LANS EXAMINER DATE
"APPROVED PLANS PER IRC SECTION R106.3.1."