HomeMy WebLinkAboutCNEW2007-00399O'I.319
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number 07-00002836 Date. 9/18/07
Application pin number . . . 528320
Property Address . . . . . . 1200 HARVEY RD
Property ID: 3`
Application type description TEMP POLE. �/ 443019
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . . .GENERAL COMMERCIAL
Application valuation . . . . 0
Owner
------------------------
Contractor
------------------------
D&C CONTRACTING
10126 TALLEY LN
HOUSTON
TX 77041
(713) 460-9394
----------------------------------------------------------------------------
Permit . . . . .
. TEMP POLE
PERMIT
Additional desc .
. GS
Permit pin number
525477
Permit Fee
20.00
Issue Date . . .
----------------------------------------------------------------------------
. 9/18/07
Valuation . . .
. 0
Other Fees . . .
----------------------------------------------------------------------------
. . . . . .
TEMP ELECT POLE CONNECT
45.00
Fee summary
-----------------
Charged
Paid Credited
Due
Permit Fee Total
----------
20.00
------------------------------
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
-------------------
BUILDING DE
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION,
1101 TEXAS AVENUE, COLLEGE STATION,'& 77840
PHONE: (979)764-3570 FAX: (979)764=3496
http://bpinspect.cstx.gdv
----------------------------------------------------------------------------
Application Number . . . . .
Application pin number . . .
Property Address . . . . . .
Property ID:
R #.
Tenant nbr, name . . . . . .
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
Owner
------------------------
--------------------- Structure
Construction Type . . . . .
Occupancy Type . . . . . .
Other struct info . . . . .
07-00000399
276949
1200 HARVEY RD
Date 7/18/07
R87856
LANDLORD IMPROVEMENTS
COMMERCIAL, STORES & CUSTOMER SERVICE
UNKNOWN
120000
Contractor
OWNER
Information 000 000 ----------------------
**NEEDS TO BE ENTERED**
**NEEDS TO BE ENTERED**
TAZ 259.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . . GS
Permit pin number . 513879
Permit Fee . . . . 520.00 Plan Check Fee .00
Issue Date . . . . 7/18/07 Valuation . . . . 120000
Expiration Date . . 1/14/08
Qty Unit Charge Per Extension
BASE FEE 460.00
20.00 3.0000 THOU BLDG, VAL 100001-500000 60.00
----------------------------------------------------------------------------
Special Notes and Comments
PROVIDE ADDRESS ON COMMERCIAL BUILDINGS -FRONT 5" NUMBERS
REAR - 2" HIGH NUMBERS WITH NAME OF BUSINESS
THE TEXAS DEPARTMENT OF HEALTH REQUIRES AN ASBESTOS SURVEY
IN CERTAIN CIRCUMSTANCES - CALL TDH @ (254) 778-6744 FOR
MORE INFORMATION
PROVIDE A KNOX BOX FOR FIRE DEPARTMENT ACCESS.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
All outdoor lighting must be in compliance with Section
7.10, Outdoor lighting Standards of the City's Unified
Development Ordinance
BUILDING DEPT 4 P S NTAT E
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 07-00000399
Application pin number . . . 276949
Page 2
Date 7/18/07
Special Notes and Comments
All roof and ground -mounted mechanical equipment shall be
sreened from view or isolated so as not to be visible from
any public right-of-way or residential district within 150
feet of the subject lot, measured from a point five feet
above grade. Such screening shall be coordinated with the
building architecture and scale to maintain a unified
appearance. Acceptable methods of screening rooftop
equipment may include, but are not limited to encasement,
parapet walls, or partition screens.
COLLEGE STATION ELECTRICAL DIVISION REQUESTS THAT THE METER
CAN/ELECTRICAL SERVICE DISCONNECT BE LOCATED ON THE
STRUCTURE AS CLOSE AS POSSIBLE TO THE SECONDARY FEEDER
CONDUIT FROM THE TRANSFORMER.
(see site plan for location of conduit or contact
electrical division)
CONSTRUCTION ACTIVITY BETWEEN THE HOURS OF 10:00 PM AND
7:00 AM MUST COMPLY WITH THE NOISE ORDINANCE (MAX. 55 DBA)
PROVIDE PANIC HARDWARE ON EXIT DOORS
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
CONSTRUCTION CONTRACTS OVER $50,000 REQUIRE SUBMISSION TO
THE STATE FOR ACCESSIBILITY REVIEW - CONTACT TDLR
(512) 463-3211 FOR MORE INFORMATION
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
Fee summary Charged Paid Credited Due
---------------------------------------------------------
Permit Fee Total
Plan Check Total
Grand Total
BUILDING DE
APPLICANT:
520.00 520.00 .00 .00
.00 .00 .00 .00
520.00 520.00 .00 .00
(*//q"
CITY OF COLLEGE STATION
Planning & Development Semica
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
WWW.CSTX.GOV
ADDRESS/LOCATION' 1200 Harvev Road
FO Office Use Onty
DATE: RRCC REEGG
APPLICATION # D]
TEMP POLE #
LOT 2R BLOCK 1 SUBDIVISION "PT OF POST OAK SQUARE CENTER"
SEC/PH
BUSINESS/OWNER NAME: FIDELIS REALTY PARTNERS PHONE: (713) 623-6800
CONTRACTOR/HOMEOWNER: OUT FOR BID
CONTRACTOR ADDRESS: OUT FOR BID
ELECTRICIAN: OUT FOR BID
HVAC: OUT FOR BID
PHONE:
PLUMBER: OUT FOR BID
_ GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
x DEMOLITION (Asbestos Survey) NEW CONSTRUCTION ' SLAB ONLY
DUPLEX (Landscape Plans x REMODEURENOVATION" SWIMMING POOL
Required)
DESCRIPTION OF WORK: Make -Ready for tenant
STRUCTURE USE: Mercantile
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJA7809911
o
VALUATION: $120,000 TOTAL ARE 4. 4- 7-os4. HEATED AREA�.1.17-9s:f.
s (Cost of Labor and Materials)
❑ PUBLIC SEWER NUMBER OF BEDROOMS: N/A
❑ SEPTIC/TREATMENT SYSTEM
❑ SEWER TAP:
nWATER TAP:
OTHER TAP:
TEMP POLE
JILt
SIZE
SIZE
GARAGE TYPE: SINGLE
ATTACHED
NUMBER OF BATHROOMS: 2
INTERIOR WALL TYPE: GYP.BD./MTL
EXTERIOR WALL TYPE: PLASTER/E.I.F.S./STONE ON
MTL. STUDS
FOUNDATION TYPE: EXISTING
ROOF TYPE: SINGLE PLY
DOUBLE F—] TRIPLE
IFnTACH 4 E:3 ARPORT F
SIGNATURE OF APPLICANT: _ a 7 %' //%
*If proposed work involves new c merc al construction or facade improvements/renovations to an existing
commercial property, building elevations are required.
Official Use Only
CESr4 NO
Aloe-57 0 1 5u ✓vQ% i`I c
Page 2 of 2
2/15/2007
Plans Examiner
Zoning Official `
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor
R value of ductwork
A/C SEER Rating
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
u
ACI
AMERICAN CONSTRUCTION INVESTIGATIONS, LTD.
602 SAWYER STREET, SUITE 200, HOUSTON, TEXAS 77007-7510
(713)864-8494 1-888-595-8500 FAX:(713) 864-8495
email aci@acico.wm
ACCESSIBILITY SPECIALISTS
Registered with
TEXAS DEPARTMENT OF LICENSING AND REGULATION
ARCHITECTURAL BARRIERS
TAS PLAN REVIEW & INSPECTION APPLICATION
Firm's Project No.
We, CDA Architects Inc.
04104-POLL
(Architect -of -Record,
Engineer, Interior Designer or Owner) request that ACI (American Construction Investigations, Ltd.) provide a
plan review of Post Oak Square - Landlord White Box ( Project Name)
for compliance with the Elimination of Architectural Barriers Act, (Texas Government Code, Chapter 469).
We understand that in performing such services, ACI is assuming none of the responsibilities of the Architect -of -Record for design,
suitability of purpose or compliance with any law or regulation including the Americans with Disabilities Act (ADA), (P.L. 101-336).
We further understand that the opinions of ACI are for the limited purpose of meeting State requirements for such review & inspection
under the statute and do not constitute a warranty or representation for any purpose. We agree that the limit of liability of ACI for any
claim against it for services performed under this agreement shall be the sum of its fee pursuant to this agreement.
ORDER INFORMATION
Construction Cost
Review
Inspection
Review
*Inspection
*ACI will accept
prepayment of the
Inspection fees for
projects completed
within 6 months
of submittal date.
ACI retains the project
TDLR - TAS file folder.
Therefore, files are available
immediately for ACI to
perform inspections.
$0 - $49 999
$200
$200
50,000 - 200,000
250
350
$250.00
$350.00
200,001 - 500,000
315
375
500.001 - 1,000,000
380
400
1.000,001 - 5,000,000
445
445
5,000,001 - 10,000,000
575
575
10 000,001 - 15,000,000
620
620
15 000,001 - 25,000,000
785
785
25,000,001 - 50,000,000
955
955
50 000.001 - 75 000,000
1 175
1,175
75,000,001 - or eater
Contact ACI for negotiated fee.
Project Completion Date:
6/30/2007
One time Project Filing Fee to be paid at Review submittal
$175.00
----------
7 ravel expense for outside 20-mile radius of downtown Houston
----------
48 hours/2 working days service $100
Total Review & Ins ection
,I Application must be accompanied by payment in full. Total
$425.00
$350.00
$775.00
For Free Pick-up: Call 713-864-8494 or 1-888-595-8500
❑ Send me a submittal receipt by facsimile.
ACl can review & inspect both privately and publicly financed projects Financed construction projects which are leased to the State or a
political subdivision must be applied to TDLR in Austin for review and inspection. The plan review fee includes only one resubmittal
review. Our normal expected plan review period is about 10 working days, however guaranteed 48 hours/2 working days service is offered
for an additional $100 charge. Call prior to submitting to confirm availability. Inspection fee is for one field inspection for projects within
a 20••nlile radius of downtown Houston. Call for inspection travel expenses outside a 20 mile radius of downtown Houston.
Attached:
❑ Completed ACI TAS Plan Review & Inspection Application (This form).
❑ Completed TDLR Architectural Barriers Project Registration form (Separate form).
Cl One complete set of construction documents for all disciplines for Plan Review.
❑ Check or money order for total price payable to ACI or (American Construction Investigations, Ltd.)
For remodeling projects where facility has been previous reviewed or inspected please provide EABPRJ:
Pleaseovideptkner fj�j number whether inspection fee is paid or not. Owner's Fax No: ( 713 ) 623-6804
M
( 281) 440-3301 ( 281) 440-3755
'Authori2 ed SigA&re Date 'Telephone
Authorized Signature Name above: Charles L. Chambliss Email Address
Office Contact for Correspondence: Ann M. Thomas Email Address
Fax
charlesc@cdaarchitects.com
annt@cdaarchitects.com
ABProjRegForm
http://www.license.state.tx.us/abproj ectregistration/ABProjRegFormV...
Texas Department of Licensing and Regulation
Architectural Barriers Project Registration Confirmation Page
Thursday, February 15, 2007
EABPRJA7809911
PERSON FILING FORM
Name: ANN THOMAS Email: AnnT@CDAarchitects.com Phone:
281-440-3301
Project Name: Post Oak Square - Landlord White Box
Project Post Oak Square Shopping Center
Address: 1200 Harvey
College Station, TX 77840 County: Brazos
TENANT Name: Phone: —
Tenant Address:
Contact Name: Phone: --
Contact Address:
BUILDING/FACILITY Name: Post Oak Square Shopping Center
FACILITY Owner: Post Oak Square Partners Phone: 713-623-6800
Owner Address: 19 Briar Hollow Lane #100, HOUSTON, TX 77027
Contact Name: Kevin Curry Phone: 713-623-6800
Contact Address: 19 Briar Hollow Lane #100, HOUSTON, TX 77027
DESIGN FIRM Name: CDA ARCHITECTS INC Phone: 281-440-3301
Firm Address: 14403 CORNERSTONE VILLAGE DR, HOUSTON, TX
77014-1206
Designer Name: CHARLES L CHAMBLISS Email:
CHARLESC@CDAARCHITECTS.COM
Type of License: Architect License Number: 3754
PROJECT DESCRIPTION
Start Date: 04/2007 Completion date: 06/2007 Estimated
Cost: $120,000.00
Type of Work: Renovation/Alteration
Does this building(s) have more than one level? No
Are there any elevators, escalators, or platform lifts in this building?
No
Type of Funds: This project is privately funded, on private land for private
use.
State Lease No.
Scope of Work: Landlord to prepare existing lease space for new tenant
(white box)
I will submit this AB Confirmation Page with a complete set of construction documents and applicable fees to a Registered
Accessibility Specialist (RAS) or Contract Provider.
I hereby notify the Texas Department of Licensing and Regulation of the described project and of my intent to perform, or
cause to be performed, all services necessary to design said project in accordance with the provisions of Texas
Govern ent odelghapter 469. 1 certify that I am the registered design professional with overall responsibility for the
desio iat'ectasd whose seaLis- a to the construction documents.
Professional Date Email Address
OR
I hereby notify the Texas Department of Licensing and Regulation of my intent to comply with the provision of Texas
Government Code, Chapter 469.
Signature of Building Owner or Designated Agent Date Email Address
1 of 2 2/15/2007 1:41 PM
http://www.brazoscad. org/Appraisal/PublicAccess/PropertyDetail-asp...
D
Brazos County Appraisal District
1673 Briarcrest Drive Suite A-101, Bryan, Texas 7'r302
�
I
Telephoue: 979-7744100 Office Hours: Monday- Friday li:00zt - 5:00PD1
Home
4
Property Detail Sheet (R87856)
General Information
c-' 1 History
0 Datasheet Statement Bills ; Tax History
News
Owner Information
FAQ
Owner ID: 00006197
Searches
Owner Name: POST OAK SQUARE PARTNERS
Property ID Search
Owner Address: 19 BRIAR HOLLOW LN STE #100
MOUSTON,TX 77027.2801
Account Search
Property Address: 1100 HARVEY RD
Owner Search
Parcel Information
Address Search
Legal Description: POST OAK SQUARE, BLOCK 1, LOT 2R, ACRES 10.42, "PT OF POST OAK SQUARE CENTER"
Property Data
Acreage:
Cross Reference: 514300-0001-0020
Detail Sheet
Undivided Interest: 100%
History
Exemption Codes:
Entity Codes: C2 (CITY OF COLL. STAT.)
Datasheet
G1 (BRAZOS COUNTY)
S2 (COLLEGE STATION ISO)
Bills
Deed Type: WARRANTY DEED
Other
Deed Book: 6438
Taxing Units
Deed Page: 074
Map Page: 561-212
Neighborhoods
Abstracts
Land HS: $0 +
Land NHS: $1,874,590 +
Subdivisions
Improvement HS: $0 +
FORMS & APPLICATIONS
Improvement NHS: $2,676,160 +
Ag Market: $0
Ag Use: $0 +
Timber Market: $0
Timber Use: $0 +
Assessed: $4,550,750 =
Improvements
ID Type
Imp1 C (Commercial)
Imp2 C (Commercial)
Imp3 C (Commercial)
I
C
ID Type
Land1 2 (Commercial;
cer cdobl �" gdobe Ac
Reader'
R87856 Page I of 2 r.
POST OAK SQUARE PARTNERS (00006197)
19 BRIAR HOLLOW LN STE #100
HOUSTONJX 77027-2801
5 10111 UTU UTWA V Ill
POST OAK SQUARE, BLOCK 1, LOT 2R, ACRES 10.42, "PT OF
POST OAK SQUARE CENTER"
C2, G1, S2
750
Imp HS
$0
$0
Imp NHS
$2,676,160
$0
$1,888,940 $1,825,580 $1,780,510
Y
4X.91N M,
WEN
w 4
Land HS
$0
, if q R
% gig; j
Cr ,� 7P e ,
1 01 M I W,
MR.-
$1,874,590 $1,874,590 $1,874,590
41 1.311,
liillqiM
I
"i "
Land NHS
$1,874,590
12/16/2004
6438
074
POST OAK SQUARE LTD
Ag Mkt
$0
$0 - -
05/28/1993
1805
185
FDIC FOR NCNB TEXAS NATIONAL E
Aq Use
$0
$0 - -
12/09/1991
1384
075
NCNB TEXAS NATIONAL BANK
Tim Mkt
$0
$0 - -
12/04/1990
1224
621
LISTER PROPERTIES CO
Tim Use
$0
$0 - -
HS Cap
-
- -
Assessed
$4,550,750
$3,763,530 $3,700,170 $3,655.100
I SF ICS JCB ISR IMT jCP I
Ki,
o
SIX,
'M Pir
affbOV
1, 1 PINES!
AH ign
Years
C Commercial $3,131,050
MA Main Area 91724 1983 1983 $3.068,760
OP Open Porch 6204 $62,290
I F1 Commercial
453895.00F 1.874,590
R87856 Page 2 of 2
"
#NN N`l*&n
0E
a,ffiU-
- AC
POST OAK SQUARE PARTNERS (00006197)
POST OAK SQUARE, BLOCK 1, LOT 2R, ACRES 10.42, "PT OF
4,550,750
19 BRIAR HOLLOW LN STE #100
POST OAK SQUARE CENTER"
HOUSTONJX 77027-2801
i ti 6kROM
R,
6 bffi
-, ET:
--
,'
C2, G1, S2
0
22 RIN
fli
1100 HARVEY RD
Imp HS $0 $0
Imp NHS $2,676,160 $1,888,940 $1,825,580 $1,780,510
P p
..if AW.'-.2 1- � ,
ame a
Land HS $0 $0
$1,874,590
1 w 7, --'n- 1 T. '. �x -,N
Land NHS $1,874,590 $1,874,590 $1,874,590
12/16/2004 6438 074 POST OAK SQUARE LTD
Ag Mkt $0 $0
05/28/1993 1805 185 FDIC FOR NCNB TEXAS NATIONAL I
Ag Use $0 $0
12/09/1991 1384 075 NCNB TEXAS NATIONAL BANK
Tim Mkt $0 $0
12/04/1990 1224 621 LISTER PROPERTIES CO
Tim Use $0 $0
HS Cap - -
Assessed $4,550,750 $3,763,530 $3,700,170 $3,655,100
M IMMIMA
M "• 'M l s* Ism
AFIWMN
N'al
N MINE
N 0
M, '-Rd6fd
SF
CS
CB
SR
MT
CID
q Fr,
ON Bath*Q
AH
1987
INWE `WO'&=
Improvements
s
�0' --tif -y "g-,4
-1-'. -;W!4 .7;, n� V i
!Z MM
C Commercial $309,610
MA Main Area 6000 1987 1987 $299,140
OP Open Porch 700 1987 1987 $10,470
C Commercial $456,000
Land! Se
E, y:kiMMAr§.'�Market
v A V,
F1 Commercial 453895.00F 1,874,590
ADMINISTRATION
101.4 Compliance. Compliance with this code shall be deter-
mined in accordance with Sections 101.4.1 and 101.4.2.
101.4.1 Residential buildings. For residential buildings the
following shall be used as the basis for compliance assess-
ment: a systems approach for the entire building (Chapter
4), an approach based on performance of individual compo-
nents of the building envelope (Chapter 5), an approach
based on performance of the total building envelope (Chap-
ter 5), an approach based on acceptable practice for each en-
velope component (Chapter 5), an approach by prescriptive
specification for individual components of the building en-
velope (Chapter 5), or an approach based on simplified, pre-
scriptive specification (Chapter 6) where the conditions set
forth in Section 101.4.1.1 or 101.4.1.2 are satisfied.
101.4.1.1 Detached one- and two-family dwellings.
When the glazing area does not exceed 15 percent of the
gross area of exterior walls.
101.4.1.2 Residential buildings, Group R-2, R-4 or
townhouses. When the glazing area does not exceed 25
percent of the gross area of exterior walls.
101.4.2 Commercial buildings. For commercial buildings,
a prescriptive or performance -based approach (Chapter 7)
or as specified by acceptable practice (Chapter 8) shall be
used as the basis for compliance assessment.
SECTION 102
MATERIALS, SYSTEMS AND EQUIPMENT
102.1 General. Materials, equipment and systems shall be
identified in a manner that will allow a determination of their
compliance with the applicable provisions of this code.
102.2 Materials, equipment and systems installation. All in-
sulation materials, caulking and weatherstripping, fenestration
assemblies, mechanical equipment and systems components,
and water -heating equipment and system components shall be
installed in accordance with the manufacturer's installation in-
structions.
102.3 Maintenance information. Required regular mainte-
nance actions shall be clearly stated and incorporated on a
readily accessible label. Such label shall include the title or
publication number, the operation and maintenance manual for
that particular model and type of product. Maintenance instruc-
tions shall be furnished for equipment that requires preventive
maintenance for efficient operation.
102.4Insulation installation. Roof/ceiling, floor, wall cavity
and duct distribution systems insulation shall be installed in a
manner that permits inspection of the manufacturer's R-value
identification mark.
102.4.1 Protection of exposed foundation insulation. In-
sulation applied to the exterior of foundation walls and
around the perimeter of slab -on -grade floors shall have a
rigid, opaque and weather -resistant protective covering to
prevent the degradation of the insulation's.thermal perfor-
mance. The protective covering shall cover the exposed area
of the exterior insulation and extend a minimum of 6 inches
(153 mm) below grade.
102.5 Identification. Materials, equipment and systems shall
be identified in accordance with Sections 102.5.1, 102.5.2 and
102.5.3.
102.5.1 Building envelope insulation. A thermal resis-
tance (R) identification mark shall be applied by the manu-
facturer to each piece of building envelope insulation 12
inches (305 mm) or greater in width.
Alternatively, the insulation installer shall provide a
signed and dated certification for the insulation installed in
each element of the building envelope, listing the type of in-
sulation installations in roof/ceilings, the manufacturer and
the R-value. For blown -in or sprayed insulation, the installer
shall also provide the initial installed thickness, the settled
thickness, the coverage area and the number of bags in-
stalled. Where blown -in or sprayed insulation is installed in
walls, floors and cathedral ceilings, the installer shall pro-
vide a certification of the installed density and R-value. The
installer shall post the certification in a conspicuous place
on the job site.
102.5.1.1 Roof/ceiling insulation. The thickness of
roof/ceiling insulation that is either blown in or sprayed
shall be identified by thickness markers that are labeled
in inches or millimeters installed at least one for every
300 square feet (28 in') throughout the attic space. The
markers shall be affixed to the trusses or joists and
marked with the minimum initial installed thickness and
minimum settled thickness with numbers a minimum of
1 inch (25 nun) in height. Each marker shall face the attic
access. The thickness of installed insulation shall meet or
exceed the minimum initial installed thickness shown by
the marker.
102.5.2 Fenestration product rating, certification and la-
beling. U-factors of fenestration products (windows, doors
and skylights) shall be determined in accordance with
NFRC 100 by an accredited, independent laboratory, and la-
beled and certified by the manufacturer. The solar heat gain
coefficient (SHGC) of glazed fenestration products (win-
dows, glazed doors and skylights) shall be determined in ac-
cordance with NFRC 200 by an accredited, independent
laboratory, and labeled and certified by the manufacturer.
Where a shading coefficient for a fenestration product is
used, it shall be determined by converting the product's
SHGC, as determined in accordance with NFRC 200, to a
shading coefficient, by dividing the SHGC by 0.87. Such
certified and labeled U-factors and SHGCs shall be ac-
cepted for purposes of determining compliance with the
building envelope requirements of this code.
When a manufacturer has not determined product U-fac-
tor in accordance with NFRC 100 for a particular product
line, compliance with the building envelope requirements of
this code shall be determined by assigning such products a
default U-factor in accordance with Tables 102.5.2(1) and
102.5.2(2). When a SHGC or shading coefficient is used for
code compliance and a manufacturer has not determined
product SHGC in accordance with NFRC 200 for a particu-
lar product line, compliance with the building envelope re-
quirements of this code shall be determined by assigning
such products a default SHGC in accordance with Table
2003 INTERNATIONAL ENERGY CONSERVATION CODE®
CDAArchiteetsMember American Institute Of Architects
Chambliss Design Associates, Inc.
14403 Cornerstone Village Drive, Houston, Texas 77014
www.cdaarchitects.com QQ
Voice 28i-
440-3301 Fax 281-440-3755
LETTER OF TRANSMITTAL
TO: City of College Station DATE: 2/14/07
1101 Texas Ave. ;
College Station, Texas 77840 JOB: Post Oak•Sq. - College Station
ATTN: BEN McCARTY RE: PERMIT ISSUE
We are sending you attached, the following items:
COPIES
DATE
DESCRIPTION
2/13/07
PERMIT ISSUE - Canopy Package: Construction Documents
2/13/07
PERMIT ISSUE - Canopy Package: Specifications
3 ]
2/13/07
PERMIT ISSUE - Landlord Package: Construction Documents
2/13/07
PERMIT ISSUE - 99 Cent Only Package: Construction Documents
F . -
THESE ARE TRANSMITTED as checked below:
❑ No exceptions taken ❑ Rejected
❑ Make corrections noted ❑ Revise and re -submit
® For your use/information ❑ As requested
REMARKS:
Copy to: File, CLC
Signed:
Ann M. Thomas
\\VENTURESTAR\PRODUCTIONUOBS\NINETY NINE ONLY\F7415 POST OAK\WORD\T-2007-02-14COCS.DOC
❑ Submit specified item
❑ For review and comment
El
CDAArchitects
Chambliss Design Associates, Inc.
14403 Cornerstone Village Drive, Houston, Texas 77014
www.cdaarchitects.com
Voice 281-440-33ol Fax 281-440-3755
ADDENDUM NO. i
PROJECT: POST OAK SQUARE "VANILLA" BOX
12oo HARVEY
COLLEGE STATION, TEXAS
Member American Institute Of Architects
DATE: 04/12/07
ADDENDUM: TO THE PLANS AND SPECIFICATIONS (INCLUDING ALL PREVIOUSLY ISSUED
ADDENDA) FOR THE ABOVE REFRENCED PROJECT.
ACCOMPANYING ATTACHMENTS: NONE
ACCOMPANYING FULL SIZE SHEETS: NONE
ARCH: Ao.o, D1.1,A1.1, A1.2
STRUCT: NONE
MEP: M1.1, Em
CIVIL: NONE
THE CONTRACTOR SHALL INCORPORATE THE FOLLOWING CHANGES AND/OR
REVISIONS INTO THE SCOPE OF THE WORK:
FURNISH ALL LABOR, MATERIALS AND PERFORM ALL WORK NECESSARY TO MAKE THE CHANGES
INDICATED ON THE ACCOMPANYING DRAWINGS AND/OR INDICATED BELOW.
ARCHITECTURAL:
1. SHEET Ao.o:
1.1 CORRECTED BUILDING CODE ANALYSIS TO INDICATE NEW SQUARE FOOTAGE TO 18,620
SQUARE FEET.
1.2 CORRECT SITE PLAN TO INDICATE NEW BUILDING SQUARE FOOTAGE.
2. SHEET Dia:
2J REVISED DEMOLITION PLAN TO DECREASE THE AMOUNT OF INTERIOR BEING REMOVED
DUE TO THE RELOCATION OF THE DEMISING WALL.
99� ONLY STORES — F7415 Addendum No.1 Page 1 of 5
F:\JOBS\FIDELIS\POST OAK SQUARE - COLLEGE STATION\WORD\ADDoot-200704i2.DOC
3. SHEET A1.1:
3.1 CORRECTED PLAN TO INDICATE DEMISING WALL RELOCATION REDUCING THE SIZE OF THE
SPACE TO 18, 620 SQUARE FEET.
4. SHEET Ai.2:
4.1 INDICATED NEW RTU LOCATIONS.
4.2 REVISED NOTES TO INDICATE THAT THE LANDLORD IS INSTALLING NEW RTU'S.
5. SHEET M1.1:
5.1 REVISED HVAC LOCATIONS DUE TO REDUCTION IN SQUARE FOOTAGE.
6. SHEET E1.1:
6.1 REVISED ELECTRICAL REQUIREMENTS AND DESTINATIONS DUE TO THE RELOCATION OF
DEMISING WALL.
END OF ADDENDUM.
VANILLA BOX - POST OAK SQUARE ADDENDUM NO.2
F:\iobs\Fidelis\Post Oak Square - CoUege Station\Word\ADDool-20070412.doc Page 2 Of 2
CDA* Architects
Chambliss Design Associates, Inc.
14403 Cornerstone Village Drive, Houston, Texas 77014
www.cclaarchitects.com
Voice 281-440-33oi Fax 281-440-3755
ADDENDUM NO. i
Member American Institute Of Architects
PROJECT: POST OAK SQUARE "VANILLA" BOX DATE: 04/12/07
12oo HARVEY
COLLEGE STATION, TEXAS
ADDENDUM: TO THE PLANS AND SPECIFICATIONS (INCLUDING ALL PREVIOUSLY ISSUED
ADDENDA) FOR THE ABOVE REFRENCED PROJECT. .
ACCOMPANYING ATTACHMENTS: NONE
ACCOMPANYING FULL SIZE SHEETS: NONE
ARCH: Ao.o, Di.i,Ai.i, A1.2
STRUCT: NONE
MEP: Mm, Ei.1
CIVIL: NONE
THE CONTRACTOR SHALL INCORPORATE THE FOLLOWING CHANGES AND/OR
REVISIONS INTO THE SCOPE OF THE WORK:
FURNISH ALL LABOR, MATERIALS AND PERFORM ALL WORK NECESSARY TO MAKE THE CHANGES
INDICATED ON THE ACCOMPANYING DRAWINGS AND/OR INDICATED BELOW.
ARCHITECTURAL:
1. SHEET Ao.o:
1.1 CORRECTED BUILDING CODE ANALYSIS TO INDICATE NEW SQUARE FOOTAGE TO 18,620
SQUARE FEET.
1.2 CORRECT SITE PLAN TO INDICATE NEW BUILDING SQUARE FOOTAGE.
2. SHEET D1.1:
2.1 REVISED DEMOLITION PLAN TO DECREASE THE AMOUNT OF INTERIOR BEING REMOVED
DUE TO THE RELOCATION OF THE DEMISING WALL.
99� ONLY STORES — F7415 Addendum No.1 Page 1 Of 5
F:\JOBS\FIDELIS\POST OAK SQUARE - COLLEGE STATION\WORD\ADDoot-20070412.DOC
3. SHEET Al.i:
3.1 CORRECTED PLAN TO INDICATE DEMISING WALL RELOCATION REDUCING THE SIZE OF THE
SPACE TO 18, 620 SQUARE FEET.
4. SHEET A1.2:
4.1 INDICATED NEW RTU LOCATIONS.
4.2 REVISED NOTES TO INDICATE THAT THE LANDLORD IS INSTALLING NEW RTU'S.
5. SHEET Mi.1:
5.1 REVISED HVAC LOCATIONS DUE TO REDUCTION IN SQUARE FOOTAGE.
6. SHEET El.i:
6.1 REVISED ELECTRICAL REQUIREMENTS AND DESTINATIONS DUE TO THE RELOCATION OF
DEMISING WALL.
END OF ADDENDUM.
VANILLA BOX - POST OAK SQUARE ADDENDUM NO.2