HomeMy WebLinkAboutRES2007-00390, 07-410I
(7/b/2007) Gma Southerland - Re: Calling for C.O. @ 3701 Bridle Ct. J VW A ^ v� M Page 1 `1
From: Mitchell Carson
To: Benjamin McCarty; Chris Haver; Gina Southerland; Joe Garcia; Kim Wol...
Date: 7/5/2007 8:23 AM
Subject: Re: Calling for C.O. @ 3701 Bridle Ct.
This one is OK Mitch
>>> Gina Southerland 07/03/07 2:10 PM >>>
Bp# 07-390
Gina Southerland
CSR - Planning & Development Services
City of College Station
979-764-3570
www.cstx.4ov
WFO877716 / 001 City of College Station PAGE 1
REQ. DATE: 02/28/07 02/28/07 13:49:22
LOCATION: 3701 BRIDLE CT j, LOC ID: 200626
REQUESTOR: K D HOMEBUILDERS ORIGIN: CUSTOMER -WALK IN
REQ USER: KWOLFE AUTH USER:KWOLFE WRK TYPE:
TEMP POLE PASSED
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 02/28/07 SCHED COMPLETION: 02/28/07
********************************************************************************
JOB ORDER RESULT CONIlKENTS
PREPARED 6/29/07, 11:52:01 INSPECTION TICKET PAGE 13
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 6/29/07
------------------------------------------------------------------------------------------------
ADDRESS . : 3701 BRIDLE CT SUBDIV: BRIDLE GATE ESTATES PH 2
CONTRACTOR K D HOMEBUILDERS PHONE
OWNER OAKWOOD CUSTOM HOMES GROUP LTD PHONE
PARCEL 159010-0202-0280
APPL NUMBER: 07-00000390 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
-------------------------------------------------------------------------------------------------
B100 01 2/26/07 JGM BLDG, FOUNDATION -SLAB TIME: 17:00
2/26/07 AP February 26, 2007 8:57:23 AM ncochran.
Strings On Setbacks O.K.
Slab Ground Installed
B115 01 3/28/07 JGM BLDG, FRAMING TIME: 17:00
3/28/07 AE March 27, 2007 11:27:08 AM ncochran.
Sheetrock Fireplace Chase, Firestopping
B130 01 3/29/07 RH BLDG, INSULATION TIME: 17:00
3/29/07 DP March 28, 2007 3:54:14 PM kwolfe.
AFTERNOON
03/29/2007 03:17 PM RH PDA
Did not fix previous notes. Install fireplace and
firestopping in fireplace chase.
B130 02 3/30/07 JGM BLDG, INSULATION TIME: 17:00
3/30/07 AP March 29, 2007 3:45:24 PM kwolfe.
B125 01 6/29/07 BI BLDG, FINAL TIME: 17:00
_;L;1-0 7 June 29, 2007 8:08:34 AM kwolfe.
-------------------------------------- COMMENTS AND NOTES �-------------------------
nM '(LRZGATToro l
IUv
Date: 6/29/2007
Inspection Comments for Finals
Permit Year: 7 Permit Number: 390
Address: 3701 BRIDLE CT
Insp.
Inspection Type Code
Description
p.
Status
Inspection Result Comments
B100
BLDG, FOUNDATION -SLAB
IC
Strings On Setbacks O.K.
B100
BLDG, FOUNDATION -SLAB
IC
Slab Ground Installed
B115
BLDG, FRAMING
IC
Sheetrock Fireplace Chase, Firestopping
B130
BLDG, INSULATION
IC
03/29/2007 03:17 PM RH PDA
B130
BLDG, INSULATION
IC
Did not fix previous notes. Install fireplace and
B130
BLDG, INSULATION
IC
firestopping in fireplace chase.
E150
ELEC, FINAL
IC
06/22/2007 04:23 PM JGM PDA
E150
ELEC, FINAL
IC
acorn clamp loose on ground rod, need proper box to water
E150
ELEC, FINAL
IC
heater, need access to jacuzzi plug, open box in attic
E150
ELEC, FINAL
IC
06/27/2007 03:13 PM RH PDA
E150
ELEC, FINAL
IC
Need proper location of access to jacuzzi tub in order to
E150
ELEC, FINAL
IC
test GFI plug and for servicing the equipment. Install
E150
ELEC, FINAL
IC
proper plug box in water heater cabinet.
E150
ELEC, FINAL
IC
06/28/2007 02:16 PM RH PDA
E150
ELEC, FINAL
IC
Electrical supply wire for water heater needs proper
E150
ELEC, FINAL
IC
bushing around cut opening to protect wire.
Page 1
WFO875691
/ 001 City of. College
Station
PAGE 1
REQ. DATE:
02/21/07
02/21/07
10:10:41
LOCATION:
3701 BRIDLE CT
LOC ID:
200626
REQUESTOR:
K D HOMEBUILDERS
ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER:
KWOLFE
WORK TYPE:
ROUT
4" SWR
TAP 3/4" WTR TAP
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT
SET
READY
SCHED START: 02/21/07 SCHED
COMPLETION:
02/21/07
JOB ORDER
RESULT COMMENTS
City of College Station
1101 TEXAS AVENUE
COLLEGE STATION TX 77840
C E R T I F I C A T E O F O C C U P A N C Y
P E R M A N E N T
Issue Date . . . . . . 7/19/07
Parcel Number . . . . . 159010-0202-0280
Property Address . . . 3701 BRIDLE CT
COLLEGE STATION TX 77845
Subdivision Name BRIDLE GATE ESTATES PH 2
Legal Description BRIDLE GATE ESTATES #2, SECTIO
N 2, BLOCK 2, LOT 28
Property Zoning . . . . SINGLE FAMILY RESIDENTIAL
Owner . . . . . . . . . OAKWOOD CUSTOM HOMES GROUP LTD
Contractor . . . . . . K D HOMEBUILDERS
Application number 07-00000390 000 000
Description of Work RESIDENTIAL, 1 UNIT DETACHED NEW
Construction type . . . COMBUSTIBLE (UNPROTECTED)
Occupancy type . . . . RESIDENTIAL-SFR/DUPLEX
Flood Zone . . . . . .
Approved . . . . . . .
IV• .
B ilding Official
VOID UNLESS SIGNED BY BUILDING OFFICIAL
1 �
\ \ 189.01'
REAR SETBACK \
N
Q�
m
\
\
n
n
N
M
BRIDLE GATE DR.
SITE PLAN
SCALE: 1 "=20'-0"
BUILDING PERMIT
CITY OF COLLEGE STATION
1i01 'TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Applica,t'ion Number . . . . .
Property Address . . . . . .
Property ID:
R # . .�
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
Owner
------------------------
OAKWOOD CUSTOM HOMES GROUP LTD
4012 SH 6 S
COLLEGE STATION TX 77845
07-00000390 Date 2/21/07
3701 BRIDLE CT
159010-0202-0280
R300304
RESIDENTIAL, 1 UNIT DETACHED NEW
BRIDLE GATE ESTATES PH 2
RESIDENTIAL
SINGLE FAMILY RESIDENTIAL
170000
Contractor
------------------------
K D HOMEBUILDERS
OUTSIDE CITY LIMITS-BL
COLLEGE STATION TX 77840
--- Structure Information 000 000 SINGLE FAMILY
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info . . . . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
2365.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
3.00
NUMBER OF BEDROOMS
3.00
SEWER TYPE
PUBLIC
TAZ
405.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . . KW
Permit Fee . . . . 670.00 Plan Check Fee
.00
Issue Date . . . . 2/21/07 Valuation . . .
. 170000
Expiration Date . . 8/20/07
Qty Unit Charge Per
Extension
BASE FEE
460.00
70.00 3.0000 THOU BLDG, VAL 100001-500000
210.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS OPENING (MINIMUM R UGH -FRAMED SIZE
2211
-
-------------------- ------------------------- --- -- --
BUILDING DEPT REPRES&NTATIVE:
----------
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 2
Application Number . . . . . 07-00000390 Date 2/21/07
----------------------------------------------------------------------------
Special Notes and Comments
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW.FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAI ING PATTERN,
--------------------------------------------- ------ ----p----------
BUILDI
NG DEPT REPRESENTATIVE:
n
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 3
Application Number 07-00000390 Date 2/21/07
----------------------------------------------------------------------------
Special Notes and Comments
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE REE FROM
----------------------------------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page
4
Application Number . . . . . 07-00000390 Date
2/21/07
----------------------------------------------------------------------------
Special Notes and Comments
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
Be Aware of Right Side 10' PUE and Drainage Easement
Narrow Wall Bracing Fully Sheathed with APA Garage Framing
and Interior anchors and Bracing per plans and Mofified Rear
porch windows to get 28" minimums.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER -TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
------------------------------
---------------------------
Permit Fee Total 670.00 .670.00 .00
.00
Plan Check Total .00 .00 .00
.00
Other Fee Total 750.00 750.00 .00
.00
Grand Total 1420.00 1420.00 .00
.00
---------------------------------------- 1-6----- /j - /--- �--------------
BUILDING DEPT REPRVaENTATIVE:
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number
Property Address . . . . . .
Property ID:
R #•
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
Owner
------------------------
OAKWOOD CUSTOM HOMES GROUP LTD
4012 SH 6 S
COLLEGE STATION TX 77845
07-00000410 Date 2/21/07
3701 BRIDLE CT
159010-0202-0280
R300304
TEMP POLE
BRIDLE GATE ESTATES PH 2
RESIDENTIAL
SINGLE FAMILY RESIDENTIAL
0
Contractor
------------------------
K D HOMEBUILDERS
OUTSIDE CITY LIMITS-BL
COLLEGE STATION TX 77840
----------------------------------------------------------------------------
Permit . . . . .
. TEMP POLE
PERMIT
Additional desc .
. KW
Permit Fee . . .
. 20.00
Issue Date . . .
. 2/21/07
Valuation . . .
. 0
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
TEMP ELECT
POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary
Charged
Paid
----------
Credited
--------------------
Due
-----------------
Permit Fee Total
----------
20.00
20.00
.00
.00
Other Fee Total
45.00
45.00
.00
.00
Grand Total
65.00
65.00
.00
.00
--------------------- --
BUILDING DEPT REPRESENTATIVE: ----- IL
----------
APPLICANT: A)\ I
APPLICATION FOR BUILDING PERMIT
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
_.. (979) 764-3570 (979) 764-3496 FAX
CITY OF COLLEGE STATION WWW.CSTX.GOV
Planning & Development Se-ica: I /
ADDRESS/LOCATION: A
LOT AV13LOCK ,;Z$ / SUBDIVISION
BUSINESS/OWNER NAME D y h
�O 40",e )-,,14K.Y S PHONE: %-7 Lt -41 S 71
CONTRACTOR/HOMEOWNER
CONTRACTOR ADDRESS
ELECTRICIAN: PLUMBER: �t
HVAC: LA UC 0 GOOD CENTS (Residential only):
CLASS OF WORK du
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING E�IEWTO'
LL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * DUPLEX (Landscape Plans) REMODEL/RENOVATION*
4 TENT/CANOPY
DESCRIPTION OF WORK:
�-9-'Aj
��
HEGI
"Rug"
'IVNWTER
-TalPROPOSED USE: 1��e.
�� d�-�.�-c�J�
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) P OJECT REGISTRATION# EABPRJ
/ VALUATION: $ 1-7 o l7 TOTAL AREA:333 Z HEATED AREA: 23�
(Cost of La or and Materials)
PUBLIC SEWER NUMBER OF BEDROOMS:
3
❑ SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS:
dSEWER TAP: L1INTERIOR WALL TYPE: Z x y
V SIZE
WATER TAP: V. N EXTERIOR WALL TYPE: �X
U� SIZE
OTHER TAP: FOUNDATION TYPE: \CL.'
�� ✓✓✓ �EMP SIZE POLE ROOF TYPE: N`q�
GARAGE TYPE: SINGLE 71
ATTACHED Oc
SIGNATURE OF APPLICANT:
DOUBLE F-39 TRIPLE
�ETACHED CARPORT
*If proposed work involves new commercial r i ioA-or_faNdde improvements/renovations to an existing
commercial property, building elevations are required.
Official Use Only
2�--/&—b%
— Fj P Plans Examiner
i
vS
For O/i . IUs Only
DATE CC REG
APPLICATION # 01 —
TEMP POLE #
SEC/PH49
_/
PHONE: 4 --L( S 7 1
Zoning Official 41
X-570 4-oc42ff044 r
Comments:
rm6 ' g / ES r NO
ey 4 G 44&�W- 1 zz� Azlzw
r„ tl}- O0911 d, "N'd
Fire Marshall
S r l o' DIzWej, .4-Pvg—
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
„.` Glazing U-Factor
O'IV e eo ducturk ,
e
C SEE Rating
RUT8100"OR
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# Og _ Sw) DATE: a -16 r o7
BUILDING ADDRESS:
I. Foundation Requirements
N
A. Concrete minimum fc of 3000 PSI
B. Minimum four 4 inch slab thickness
C. Vapor barrier 6 mil. Poly min.
D. Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior unless over 60' Ion
3. Spacing of beams does not exceed 15'
E. Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F. Wood foundation details indicated
MOOK
II. Framing: Floor, Wall, Ceiling and Roof Requirements
N
A. Girder or sill dimensions, grade & species
B. Floor joist size, spacing, grade & direction of span indicted on plans
C. Treated sill plate or bottom plate
D. Tenant separation in duplex
&NbK
1. One -hour rated extending to roof deck
OK
E. Header sizes indicated on plans
p
F. Emergency bedroom egress
1. Exit direct to outside
2. O enable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G. O enable bathroom window required when mechanical ventilation is not provided
H. Stud grade andspacing
I. Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J. Roof framing Ian or elevation shown
K. Ceiling joist size, spacing, grade and direction of span indicated on plans
L. Attic access location and size indicated on plans
M. Span exceeding code tables must be engineered
N. Rafter size and spacing and purlin bracing indicated.
O. Roof covering used.
P. Indicate Wall Bracing Used for Lateral Bracing
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
II. Framing: Floor, Wall, Ceiling and Roof Requirements continued
NAM
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
S. 18" Overhang allowed on zero lot line construction, perforated soffit allowed.
T. Protected openings on walls < three feet from property line
�QK
III. Stairway Requirements
OK
A. Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" diff. max.
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches above handrail
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located four or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four (4) inch sphere
IV. Fireplace Requirements (to be indicated onplans)
NA/
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must extend at least three (3) feet higher than the highest point where it
projects through the roof of a building & at least two (2) feet higher than any portion of the
building within ten (10) feet horizontal
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
V. Electrical Service Requirements
NAf011
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
VI. Plumbing Requirements
NA/
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
NAOR
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units)
7
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
N K
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
NA/
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N
Maximum drive width for residence is 25' combined for circular 12' minimum
Minimum 20 feet from driveway to side(intersecting) street
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
NA/
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
NA/
Does not block any water course or divert any flow
Elevation certificate needed
AMOK
AW�L_
PLANS EXAMINER
"APPROVED PLANS PER IRC SECTION R106.3.1."
DATE