HomeMy WebLinkAboutRES2007-003850�-305
f
(7/16/2007) Gina Southerland - Re: Calling for CO @ 411C Tiffany Trl ._.__ _Page 1 d
From: Mitchell Carson
To: Amber Carter; Benjamin McCarty; Chris Haver; Gina Southerland; Joe G...
Date: 7/ 16/2007 11:07 AM
Subject: Re: Calling for CO @ 4110 Tiffany Trl
This one is OK Mitch
>>> Kim Wolfe 07/16/07 8:18 AM >>>
any issues?
BP # 07-385
Thanks
Kimberly Wolfe, CPS/CAP
City of College Station
Planning & Development Services
(979)764-3570
www.cstx.gov
PREPARED 7/12/07, 7:34:12 INSPECTION TICKET PAGE 9
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 7/11/07
------------------------------------------------------------------------------------------------
ADDRESS . : 4110 TIFFANY TRL SUBDIV: SHENANDOAH PH 19
CONTRACTOR ED FROEHLING BUILDERS PHONE (979) 776-8266
OWNER ED FROEHLING BUILDER INC PHONE
PARCEL 569500-1950-0040
APPL NUMBER: 07-00000385 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 3/19/07 OC BLDG, FOUNDATION -SLAB TIME: 17:00
3/19/07 AP March 19, 2007 11:27:29 AM kwolfe.
Strings On Setbacks O.K.
Slab Ground Installed
B115 01 4/25/07 JGM BLDG, FRAMING TIME: 17:00
= 4/25/07 AP April 20, 2007 4:57:15 PM kwolfe.
04/25/2007 05:17 PM JGM PDA
reinstall studs at closet
B130 01 5/08/07 OC BLDG, INSULATION TIME: 17:00
5/08/07 AP May 8, 2007 9:26:38 AM glsouth.
B125 01 7/11/07 BI BLDG, FINAL TIME: 17:00
W1616-7 ,� 0 C July 11, 2007 4:25:48 PM acarter.
-------------------------------------- COMMENTS AND NOTES-------------------------------
1'j0 �C r i*sf?"4 i A 0 Y,1
'IV
Date: 7/12/2007
Inspection Comments for Finals
Permit Year: 7 Permit Number: 385
Address: 4110 TIFFANY TRL
Insp.
Inspection Type Code
Description
p.
status
Inspection Result Comments
B100
BLDG, FOUNDATION -SLAB
IC
Strings On Setbacks O.K.
B100
BLDG, FOUNDATION -SLAB
IC
Slab Ground Installed
B115
BLDG, FRAMING
IC
04/25/2007 05:17 PM JGM PDA
B115
BLDG, FRAMING
IC
reinstall studs at closet
M110
MECH, FINAL
IC
07/02/2007 03:46 PM RH PDA
M110
MECH, FINAL
IC
Furnace flue needs min. 1" of clearance from
M110
MECH, FINAL
IC
combustibles. Need proper step at raised walkway to
furnace.
Page 1
WF0876169 / 001 City of Coll.tation
PAGE 1
REQ. DATE:
02/22/07
02/22/07
13:13:30
LOCATION:
,..
4110 TIFFANY TRL
LOC ID:
204756
REQUESTOR:
ED FROEHLING BUILDERS ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
NCOCHRAN AUTH. USER: NCOCHRAN
WORK TYPE:
ROUT
4" SWR TAP
3/4" WTR TAP
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT SET
READY
SCHED START:
02/22/07 SCHED COMPLETION:
02/22/07
********************************************************************************
JOB ORDER RESULT COMIENTS
BUILDING PERMIT
OF COLLEGE STATION-= =`
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number .
. . . . 07-00000385 Date 2/22/07
Property Address . .
. . . . 4110 TIFFANY TRL
Property ID:
569500-1950-0040
R #:
R304149
Application type description
RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . .
. . . . SHENANDOAH PH 19
Property Use . . . .
. . . . RESIDENTIAL
Property Zoning . . .
. . . . SINGLE FAMILY RESIDENTIAL
Application valuation
. . . . 113520
Owner
Contractor
------------------------
ED FROEHLING BUILDER
------------------------
INC ED FROEHLING BUILDERS
3887 HIGH LONESOME
3887 HIGH LONESOME RD
COLLEGE STATION
TX 778459443 COLLEGE STATION TX 77845
(979) 776-8266
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 1720.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 2.00
NUMBER OF BEDROOMS 3.00
SEWER TYPE PUBLIC
TAZ 422.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
NC
Permit Fee . . . .
502.00 Plan Check Fee .00
Issue Date . . . .
2/22/07 Valuation . . . . 113520
Expiration Date
8/21/07
Qty Unit Charge
Per Extension
BASE FEE 460.00
14.00 3.0000
THOU BLDG, VAL 100001-500000 42.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS
THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL
BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS
OPENING (MINIMUM ROUGH -FRAMED SIZE 2211
-----------------------------------
- -- --- ---- -------------
BUILDING DEPT RE PRE
S ENTAS I VE:
APPLICANT:
BUILDING PERMIT
' CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
I PHONE: (979)764-3570 FAX: (979)764-3496-
Application Number
07-00000385
Page 2
Date 2/22/07
Special Notes and Comments
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
-------------------------------------------- -- --- ------------------
BUILDING DEPT REPRESENTA VE:
l�
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 07-00000385
Page 3
Date 2/22/07
Special Notes and Comments
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
--------------------------------------------- - - ----- ------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
` CITY OF COLLEGE STATION ,
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page
4
Application Number . . . . . 07-00000385 Date
2/22/07
----------------------------------------------------------------------------
Special Notes and Comments
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND
CLOTHES DRYERS.
Narrow Wall Bracing Fully Sheathed with APA Garage Framing
and Dining Areas and Modified Front Bedroom Window to allow
32" OSB.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------------------------------
-----------------
Permit Fee Total 502.00 502.00 .00
.00
Plan Check Total .00 .00 .00
.00
Other Fee Total 750.00 750.00 .00
.00
Grand Total 1252.00 1252.00 .00
.00
--------------------------- _- --- --- --------------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
A.
TEMPORARY POLE PERMIT
` CITY OF COLLEGE STATION ,
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
07-00000386 Date
2/22/07
Property Address . . . . .
4110 TIFFANY TRL
Property ID:
569500-1950-0040
R #:
R304149
Application type description
TEMP POLE
Subdivision Name . . . . . .
SHENANDOAH PH 19
Property Use . . . . . . . .
RESIDENTIAL
Property Zoning . . . . . . .
SINGLE FAMILY RESIDENTIAL
Application valuation . . . .
0
Owner
Contractor
------------------------
ED FROEHLING BUILDER INC
------------------------
ED FROEHLING BUILDERS
3887 HIGH LONESOME
3887 HIGH LONESOME RD
COLLEGE STATION TX 778459443
COLLEGE STATION TX
77845
(979) 776-8266
----------------------------------------------------------------------------
Permit . . . . . . TEMP POLE
PERMIT
Additional desc . . NC
Permit Fee . . . . 20.00
Issue Date . . . . 2/22/07
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . . . . . . . .
TEMP ELECT POLE CONNECT 45.00
----------------------------------------------------------------------------
Fee summary Charged
----------
Paid Credited Due
------------------------------
-----------------
Permit Fee Total 20.00
20.00 .00
.00
Other Fee Total 45.00
45.00 .00
.00
Grand Total 65.00
65.00 .00
.00
------------------------------ ---- ------------- -
BUILDING DEPT REPRESENTATIVE:
APPLICANT: _A n / .
APPLICATION FOR BUILDING PERMIT
1101 TEXAS AVENUE
4;�
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
CITY OF COLLEGE STATION yyyWyy CSTX GOV
For O e Onty
DATE: A I T CC REG
APPLICATION #
TEMP POLE #
Planning .&DevilopinniiStrvicir
ADDRESS/LO ATION: I. 1 O -7t
LOT `T BLOCK /sUBDIVISION 250E:t,11\A tZ SEC/PH 17)
BUSINESS/OWNER NAME:
CONTRACTOR/HOMEOWN
CONTRACTOR ADDRESS:
PHONE:
\G-t. LOVIAL�JL"` E PHONE: -7 L (4 0�-+�cP
-Ft,0EF-A-L-t t,JC- j t tJC,
ELECTRICIAN: 6 15 PLUMBER: (F-tPLE�,7 S
HVAC: "-� I Idt4oWrkv E GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION _,MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) 'NEW CONSTRUCTION " SLAB ONLY
DUPLEX (Landscape Plans) REMODEL/RENOVATION" SWIMMING POOL
TENT/CANOPY
DESCRIPTION OF WORK:
PROPOSED USE: ='t r�C.LE T77AM. (L�!(
HOMEOWNER ASSOC IATI ON/ARCH ITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ k 13,520.00 TOTAL AREA: 2242 HEATED AREA: 1-7Z0
(Cost of Labor and Materials)
PUBLIC SEWER
SEPTIC/TREATMENT SYSTEM
ESEWER TAP: 4 it
IZE
,t
✓ WATER TAP:
SIZE
❑ OTHER TAP:
®(TEMP POLE
GARAGE TYPE
SIZE
SINGLE a
ATTACHED
SIGNATURE OF APPLICANT:
`If proposed work involves new ommerci
commercial property, building tions re r
-1/-6 a- /6--07
NUMBER OF BEDROOMS
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE
FOUNDATION TYPE
ROOF TYPE:
BLE TRIPLE
or
Official Use
✓N//4 Plans Examiner Zoning Official
✓�A/k C ments:
/ "�-YItsvor NO
��•� Ate.
Utz tc—rK
en
an existing
E mKir-In
ire Marshall
1) t 0 K0 bf_� I V OX6��JFJLOJ &--AVO�1' 0140-1
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor
R value of ductwork
A/C SEER Rating
V
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# D � � � �S DATE: ;2_,/6 _O?
BUILDING ADDRESS:
I. Foundation Requirements
NA/ K
A.
Concrete minimum fc of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier 6 mil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior unless over 60' Ion
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F.
Wood foundation details indicated
fff6YOK
II. Framing: Floor, Wall, Ceiling and Roof Requirements
N
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
fiQ0K
1. One -hour rated extending to roof deck
OK
E.
Header sizes indicated on plans
F.
Emergency bedroom egress
1. Exit direct to outside
2. O enable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
O enable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
N.
O.
P.
Span exceeding code tables must be engineered
Rafter size and spacing and purlin bracing indicated.
Roof covering used.
Indicate Wall Bracing Used for Lateral Bracing
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
II. Framing: Floor, Wall, Ceiling and Roof Requirements continued
N
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
S. 18" Overhang allowed on zero lot line construction, perforated soffit allowed.
T. Protected openings on walls < three feet from property line
N OK
ZIA
III. Stairway Requirements
104JOK
A. Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" diff. max.
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches above handrail
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located four or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four (4) inch sphere
IV. Fireplace Requirements (to be indicated onplans)q/
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must extend at least three (3) feet higher than the highest point where it
projects through the roof of a building & at least two (2) feet higher than any portion of the
building within ten (10) feet horizontal
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
V. Electrical Service Requirements
N
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
VI. Plumbing Requirements
N O
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
NA/ K
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
Vill. Energy Requirements
N
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N O
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N K
Maximum drive width for residence is 25' combined for circular 12' minimum
Minimum 20 feet from driveway to side(intersecting) street
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
IN
Does not block any water course or divert any flow
Elevation certificate neededE?QOK_
PLANS EXAMINER DATE
"APPROVED PLANS PER IRC SECTION R106.3.1."
% hob. 14, 2N 1:3IfIVI V!cUure & bfowne tng!5urveying, No, 24A N. 1
l
A*a6wdf AWAWFAM49 M *1 WfAft&jb>aYec JWAKrem 7AW'AM)W"
Lot 04 Block S0.dwp
CURT TABLE
CURVE DELTA KWUS LG WH CHORD, ORO.
C1 23'0B'58' 74,50' 30.14' S 33'23'13' E
C2 4731'59- 50.00' 43.23' S W34'44- E
Tiffany Tr011
50' Raw.. — 27' Powment
I. J vo/ 7.W, Pg. lot
11ock/Cvrb
ISca{e: 1" 20'
•1 r�i`1L`�rV1�:fif' 1
Proposed
Residence
4110lioyrm#
Lot A cloak 50
Shenandoah Ph=# 19
V1 Lot 4
Now or Ed Froehling Bu>Ider. Inc.
\ • \ Val. 7343. Pg. 101
Jib
—........ ...... _.,_.._.,_ .— , �..— .—
Nate: Buttdle9 Setback Linee (9.S.L)
per Pty 0 College $cation Urrfed
Development OrAwnee 12617
20' P.U.E.
I N 4456'36" W — 12.1 1' Y
Let 6 Lot 6
I I Now or Formerly Now or Formerly
Ed FroeMing Bullda, ft. Ed freeAlinngq Builder, Inc.
Val. 7343, Pg. 101 Vol 7343. Pg. 101
REScheck Compliance Certificate
2000 IECC
REScheckSoftware Version 3.5 Release lb
Data filename: C:\Program Files\Check\REScheck\1500BF.rck
TITLE: 4110 TIFFANY TRAIL
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 01 / 15/07
DATE OF PLANS: FEBRUARY 02, 2003
PROJECT INFORMATION:
LOT 4 BLOCK 50
SHENANDOAH 19
COMPANY INFORMATION:
ED FROEHLING BUILDER, INC.
NOTES:
1404 DAYTON WITH 2O05 CODE CHANGES
3-BED COOPER
COMPLIANCE: Passes
Maximum UA = 655
Your Home UA = 533
18.6% Better Than Code (UA)
Maximum SHGC = 0.40
Your SHGC = 0.37
Ceiling 1: Flat Ceiling or Scissor Truss
Wall 1: Wood Frame, 16" o.c.
Window 1: Metal Frame:Double Pane with Low-E
SHGC: 0.40
Bldg. faces 0 deg. from North; Comp. orient.: Front
Projection factor: 0.23 .
Door 1: Solid
Wall 2: Wood Frame, 16" o.c.
Window 2: Metal Frame:Double Pane with Low-E
SHGC: 0.40
Bldg. faces 0 deg. from North; Comp. orient.: Left Side
Projection factor: 0.27
Wall 3: Wood Frame, 16" o.c.
Permit Number
Checked By/Date
Gross
Glazing
Area or
Cavity
Cont.
or Door
Perimeter
R-Value
R-Value
U-Factor UA
1720
30.0
0.0
60
473
13.0
0.0
32
66
0.640 42
20
361 13.0 0.0
36
399 13.0 0.0
0.400 8
27
0.640 23
22
Window 3: Metal Frame:Double Pane with Low-E
113 0.640 72
SHGC: 0.40
Bldg. faces 0 deg. from North; Comp. orient.: Back
Projection factor: 0.23
Door 2: Glass
18 0.580 10
SHGC: 0.78
Bldg. faces 0 deg. from North; Comp. orient.: Back
Projection factor: 0.20
Wall 4: Wood Frame, 16" o.c.
361 13.0 0.0 29
Window 4: Metal Frame:Double Pane with Low-E
9 0.640 6
SHGC: 0.40
Bldg. faces 0 deg. from North; Comp. orient.: Right Side
Projection factor: 0.43
Floor 1: Slab-On-Grade:Unheated
194 0.0 202
Insulation depth: 0.0'
Air Conditioner 1: Electric Central Air, 13 SEER
COMPLIANCE STATEMENT: The proposed building design
described here is consistent with the building plans, specifications,
and other calculations submitted with the permit application.
The proposed building has been designed to meet the 2000 IECC
requirements in REScheckVersion 3.5 Release lb (formerly
MECchecl and to comply with the mandatory requirements listed in
Date 1- LS-O-7