Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
RES2007-00379
3m?elp PREPARED 6/25/07, 11:15:28 INSPECTION TICKET PAGE 8 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 6/25/07 ------------------------------------------------------------------------------------------------ ADDRESS . : 107 WALCOURT LOOP SUBDIV: EDELWEISS GARTENS PH 9 CONTRACTOR J K M CLASSIC HOMES PHONE (979) 823-1119 OWNER EDELWEISS GARTEN VENTURE PHONE PARCEL 244030-0928-0040 APPL NUMBER: 07-0000037-9'RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 3/05/07 RH BLDG, FOUNDATION -SLAB TIME: 17:00 3/05/07 AP March 5, 2007 11:52:36 AM glsouth. 03/05/2007 05:06 PM RH PDA Strings up, slab ground installed. B115 01 4/26/07 OC BLDG, FRAMING TIME: 17:00 4/26/07 AP April 20, 2007 1:51:01 PM glsouth. 04/26/2007 02:45 PM RH PDA B130 01 4/26/07 RH BLDG, INSULATION TIME: 17:00 4/26/07 DA April 26, 2007 9:43:34 AM glsouth. 04/26/2007 02:46 PM RH PDA Framing not approved. 30-0.2 4/27/07 OC BLDG, INSULATION TIME: 17:00 4/27 07 AP April 27, 2007 9:48:29 AM kwolfe. 225 01 6/25/07 BI BLDG, FINAL TIME: 17:00 June 25, 2007 11:13:20 AM kwolfe. call 219-0595 to meet. you -to unlockrthe house -------------------------------------- COMMENTS AND NOTES-------------------------------------- �1 v 1z. 6/26/2007 Kim Wolfe - Re: Calling for CO @ 107 Walcourt Loop Page 1 From: Terry Boriskie To: Amber Carter; Benjamin McCarty; Chris Haver; Gina Southerland; Joe G... Date: 6/25/2007 2:53 PM Subject: Re: Calling for CO @ 107 Walcourt Loop Jerry with JKM Builders has been notified of the needed repairs. Terry Boriskie City of College Station Residential Plans Examiner 979-764-3744 >>> Paul Schoenfeld 6/25/2007 2:11 pm >>> Water needs to be raised. Sewer buried needs to be raised. Paul >>> Kim Wolfe 6/25/2007 11:22 AM >>> any issues? BP # 07-379 Thanks Date: 6/25/2007 Inspection Comments for Finals Permit Year: 7 Permit Number: 379 Address: 107 WALCOURT LOOP Insp. Inspection Type Code Description status Inspection Result Comments B100 BLDG, FOUNDATION -SLAB IC 03/05/2007 05:06 PM RH PDA B100 BLDG, FOUNDATION -SLAB IC Strings up, slab ground installed. B115 BLDG, FRAMING IC 04/26/2007 02:45 PM RH PDA B130 BLDG, INSULATION IC 04/26/2007 02:46 PM RH PDA B130 BLDG, INSULATION IC Framing not approved. M100 MECH, ROUGH IN IC 04/12/2007 11:44 AM RH PDA M100 MECH, ROUGH IN IC Remove screws from vent -a -hood pipe by framing. P105 PLBG, TOP OUT IC April 26, 2007 1:33:24 PM ncochran. Page 1 WF0875705 / 001 City of Co,llegq Station PAGE 1 REQ. DATE: r 02/21/07 � 02/21/07 10:36:45 LOCATION: 107 WALCOURT LOOP LOC ID: 203584 REQUESTOR: J K M CLASSIC HOMES ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT 4" SWR TAP 3/4" WTR TAP . ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 02/21/07 SCHED COMPLETION: 02/21/07 ******************************************************************************** JOB ORDER RESULT COM ENTS City of College Station 1101 TEXAS AVENUE COLLEGE STATION TX 77840 C E R T I F I C A T E O F O C C U P A N C Y P E R M A N E N T Issue Date . . . . . . Parcel Number . . . . . Property Address . . . Subdivision Name . . . Legal Description . . . Property Zoning . . . . Owner . . . . . . . . . Contractor . . . . . . Application number Description of Work Construction type . . . Occupancy type . . . . Flood Zone . . . . . . Approved 6/26/07 244030-0928-0040 107 WALCOURT LOOP COLLEGE STATION TX 77845 EDELWEISS GARTENS PH 9 EDELWEISS GARTENS 49, BLOCK 28 LOT 4 SINGLE FAMILY RESIDENTIAL EDELWEISS GARTEN VENTURE J K M CLASSIC HOMES 979 823-1119 07-00000379 000 000 RESIDENTIAL, 1 UNIT DETACHED NEW COMBUSTIBLE (UNPROTECTED) RESIDENTIAL-SFR/DUPLEX del • _ Bui ding Official VOID UNLESS SIGNED BY BUILDING OFFICIAL A m poi 13UIL>ING LIaIE. 10 ' P cn�4 C- i ri�So 18' 33" BUILDI� PERMIT CITY OF.'COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number 07-00000379 Date 2/21/07 Property Address . . . . . . 107 WALCOURT LOOP Property ID: 244030-0928-0040 R #: R303274 Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . EDELWEISS GARTENS PH 9 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation 129541. Owner Contractor ------------------------ EDELWEISS GARTEN VENTURE ------------------------ J K M CLASSIC HOMES 311 CECILIA LOOP 2006 CARTER CREEK COLLEGE STATION TX 778456310 BRYAN TX 77802 (979) 823-1119 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1738.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC TAZ 405.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . KW Permit Fee . . . . 550.00 Plan Check Fee .00 Issue Date . . . . 2/21/07 Valuation . . . . 129541 Expiration Date 8/20/07 Qty Unit Charge Per Extension BASE FEE 460.00 30.00 3.0000 THOU BLDG, VAL 100001-500000 90.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS OPENING ROUGH -FRAMED SIZE 2211 ---------------------------- BUILDING DE EPR ------------------- ENTATIVE : APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 07-00000379 Page 2 Date 2/21/07 Special Notes and Comments X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8" side & 16" front) For Openings >6 sq. ft. (12" side & 20" front) ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOO AL KNOWLEDGE/EFFORT THE MAXIMUM ALLOWABLE DRIV Y WIDTH ME SURED AT THE ---------------------- ------- ----------------------�-- -- -- ------- BUILDING D REPRES TATIVE: APPLI BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 3 Application Number . . . . . 07-00000379 Date 2/21/07 ---------------------------------------------------------------------------- Special Notes and Comments PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12' ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND REIG MATERIAL FR M SLAB AREA ------------------ ---------------------------------- T /�J -- --.--•----- BUILDIN DEPRE ENTATIV APPLI BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 07-00000379 Page 4 Date 2/21/07 Special Notes and Comments PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND CLOTHES DRYERS. Narrow Wall Bracing Fully Sheathed with Interior Anchors and Bracing and APA Framing at Garage and Living Room areas. Other Fees SEWER TAP 4" WATER TAP 3/4" 350.00 400.00 Fee summary Charged Paid ---------- Credited -------------------- Due ----------------- Permit Fee Total ---------- 550.00 550.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1300.00 1300.00 .00 .00 --------------------------------------------------- ------ ----------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: APPLICATION FOR BUILDING PERMIT 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX CITY OF COLLEGE STATION 'WWW.CSTX.GOV Planning. d Divilopinent S64,kir • ADDRESS/LOCATION: I0-- UP,1c©c9 z_—r ka LOT BLOCK SUBDIVISION I t.y 1Ef SS I 0 BUSINESS/OWNER NAME: I � CONTRACTOR/HOMEOWNER: v UZ/J CONTRACTOR ADDRESS:' For Office Only DATE.. 0Z(15 TRCC REG APPLICATION # TEMP POLE # J EC/PH Cl PHONE: _+ _30 i PHONE: ZI / —0 95 ELECTRICIAN: CQd pecaj/et= PLUMBER: /Olt HVAC: C k s GOOD CENTS (Residential only): X zo CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION * SLAB ONLY DUPLEX (Landscape Plans) REMODEL/RENOVATION* SWIMMING POOL TENT/CANOPY DESCRIPTION OF WORK: 44m4m� <�V6_rxuc'TrdN PROPOSED USE: HOMEOWNER ASSOC IATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: es-S TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ i2 ? 0(• 0 E) TOTAL AREA: Z 1 _19- HEATED AREA: l (Cost of Labor and Materials) So ® PUBLIC SEWER SSEPTIC/TREATMENT SYSTEM SEWER TAP: SIZE +• pWATER TAP: SI E O� OTHER TAP: SIZE � TEMP POLE NUMBER OF BEDROOMS: NUMBER OF BATHROOMS INTERIOR WALL TYPE EXTERIOR WALL TYPE FOUNDATION TYPE Cdsrt� GARAGE TYPE: SINGLE DOUB ® TRIPLE ATTACHED ACHED CARPORT SIGNATURE OF APPLIC T: *If proposed work involve commercia ns ruction facade improvements/renovations to an existing commercial property, buil g elevations ar required. Official Use Only %jc/p% Plans Examiner �G G✓//f Fully sk W "if AMA t Ali¢ 460Mr6 ROOF TYPE: Zoning Official gDZme ES r NO Fire Marshall Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC -; Glazing U-Factor R value of ductwork A/C SEER Rating . 4 6 3 % P -! PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# 0 ,7_ 3n^ DATE: BUILDING ADDRESS: I "� / 0 % W / / �-'GDV2- Ut oo I. Foundation Requirements NAOV A. Concrete minimum fc of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier 6 mil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior unless over 60' Ion 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated NOOK II. Framing: Floor, Wall, Ceiling and Roof Requirements NA/ A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex OK 1. One -hour rated extending to roof deck (ffA/)D K E. Header sizes indicated on plans F. Emergency bedroom egress 1. Exit direct to outside 2. O enable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. O enable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Exterior wall covering indicated on plans 2. Sheathing indicated on plans 3. Moisture barrier indicated on plans J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size and spacing and purlin bracing indicated. O. Roof covering used. P. Indicate Wall Bracing Used for Lateral Bracing PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX II. Framing: Floor, Wall, Ceiling and Roof Requirements continued NA/ P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations S. T. 18" Overhang allowed on zero lot line construction, perforated soffit allowed. Protected openings on walls < three feet from property line III. Stairway Requirements INT40K A. Stairway Details 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" diff. max. 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8 B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches above handrail 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor , 2. Handrails are required on stairways located four or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four (4) inch sphere IV. Fireplace Requirements to be indicated onplans) N O A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must extend at least three (3) feet higher than the highest point where it projects through the roof of a building & at least two (2) feet higher than any portion of the building within ten (10) feet horizontal PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX V. Electrical Service Requirements N A. Electrical plan to include: 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location VI. Plumbing Requirements N A. Pressure reducing valve required when water pressure exceeds 80 psi B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) VIII. Energy Requirements N A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 N Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements N K Maximum drive width for residence is 25' combined for circular 12' minimum Minimum 20 feet from driveway to side(intersecting) street Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 N Approved subdivision Plat filed Zl- Floodplain Regulations — Ordinance 1301 N Does not block any water course or divert any flow Elevation c i icate needed IMOK PLANS EXAMINER "APPROVED PLANS PER IRC SECTION R106.3.1." DATE