HomeMy WebLinkAboutRES2007-00362PREPARED 5/30/07, 7:41:28 INSPECTION TICKET PAGE 6 City ofCollege StationINSPECTOR: BUILDING INSPECTOR DATE----5/29/07 -- -------- ---- ADDRESS . : 121 KLEINE LN SUBDIV: EDELWEISS ESTATES PHS 12 CONTRACTOR B A CATHEY PHONE (979) 255-7064 OWNER . . PHONE PARCEL . . 24400-1226-0050 APPL NUMBER: 07-00000362 RESIDENTIAL, 2 UNITS NEW (DUPLEX) ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B115 01 3/16/07 OC BLDG, FRAMING TIME: 17:00 3/16/07 AP March 15, 2007 4:02:10 PM glsouth. B130 01 3/19/07 OC BLDG, INSULATION TIME: 17:00 3/19/07 AP March 19, 2007 8:46:38 AM ncochran. B125 01 5/25/07 RH BLDG, FINAL TIME: 17:00 5/25/07 DP May 24, 2007 3:18:20 PM acarter. 05/25/2007 11:43 AM RH PDA Need to install landscaping. Need to block ridge vent between units. Address meter cans. 3125 02 V30BLDG, 100 101 AP O C May29, 2007 1:40:43PMkwolfe. r ----------------------------------- COMMENTS AND NOTES r 1_ ti2c� i2- -;p,n r �✓�g�h G� a 6/5/2007 Gina Southerland - Re: Calling for C.O. 121 Kleine Ln. Page 1 From: To: Date: Subject: THIS ONE IS OK. JMG Joe Garcia Benjamin McCarty; 6/1/2007 3:15 PM Re: Calling for C.O >>> Gina Southerland 05/25/07 8:11 AM >>> BP# 07-362 Gina Southerland CSR - Planning & Development Services City of College Station 979-764-3570 www.cstx.gov Chris Haver; Gina Southerland; Kim Wolfe; Mitchell... 121 Kleine Ln. WF0873917 / 001 City of College Station PAGE 1 REQ. DATE: 02/13/07 02/13/07 15:45:22 LOCATION: 121 KLEINE LN LOC ID: 207994 REQUESTOR: B A CATHEY ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT TEMP POLE PASSED ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 02/13/07 SCHED COMPLETION: 02/13/07 ******************************************************************************** JOB ORDER RESULT COMMENTS 2 c BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . Property Address . . . . . . Property ID: R #• Application type description Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . Application valuation . . . . Owner ------------------------ 07-00000362 Date 2/19/07 121 KLEINE LN 24400-1226-0050 RESIDENTIAL, 2 UNITS NEW (DUPLEX) EDELWEISS ESTATES PHS 12 RESIDENTIAL DUPLEX RESIDENTIAL 156222 Contractor B A CATHEY PO BOX 9517 COLLEGE STATION TX 77842 (979) 255-7064 --- Structure Information 000 000 DUPLEX Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB TYPE OF GARAGE (ATT/DET) NA HEATED AREA 2630.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 6.00 NUMBER OF BEDROOMS 6.00 SEWER TYPE PUBLIC TAZ 405.00 ---------------------------- Permit . . . . . . ----------------------------------------------- BUILDING PERMIT Additional desc . . NC Permit Fee . . . . 631.00 Plan Check Fee .00 Issue Date . . . . 2/19/07 Valuation . . . . 156222 Expiration Date . . 8/18/07 Qty Unit Charge Per Extension BASE FEE 460.00 57.00 3.0000 THOU BLDG, VAL 100001-500000 171.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY -------- ----- X BUILDING DEP R PRESENTATIVE: APPLICANT: IV ?: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 07-00000362 Page 2 Date 2/19/07 Special Notes and Comments PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. 1 HOUR DUPLEX SEPERATION WALL MUST BE MAINTAINED FROM FLOOR TO ROOF DECKING. ALL PENETRATIONS MUST BE PROPERLY ADDRESSED AND MAINTAINED. ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC ------------------- ----- -- ---- ------------ RESENTATIVE: BUILDING DEPT APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 07-00000362 Page 3 Date 2/19/07 Special Notes and Comments If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. ADD SMOKE DETECTOR(S) PER NOTES ON PLANS SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE BUILDING DEPT RESENTATIVE: APPLICANT: BUILDING PERMIT ' CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 4 Application Number . . . . . 07-00000362 Date 2/19/07 ---------------------------------------------------------------------------- Special Notes and Comments PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK Narrow Wall Bracing Fully Sheathed ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total 631.00 631.00 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 631.00 631.00 .00 .00 - APPLICANT: ........:....... ..... CITY OF COLLEGE STATION Planning d' De' t&j q .t Servi ei. APPLICATION FOR BUILDING PERMIT 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX WWW.CSTX.GOV For Office Use Only DATE: SA kd TRCC REG �% J APPLICATION # v TEMP POLE # ADDRESS/LOCATION: /vf, LOT _ LOCK C�S� �BDIVISION �l��Lui�/S S ��2%.,JS EC/PH BUSINESS/OWNER NAME: 1�� C--!/ ES PHONE: SZ0 -- 6,r1eOa CONTRACTOR/HOMEOWNER: '�qA,-46 PHONE: CONTRACTOR ADDRESS: ?D, &,C -�?S/ q _ „S �r� —%'% ELECTRICIAN-- �) 'f Jd PLUMBER: �Q-�p Nf �uil�✓/�y► �-- HVAC: : Yl -�5 GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) >dNEW CONSTRUCTION * SLAB ONLY DUPLEX (Landscape Plans) REMODEL/RENOVATION* SWIMMING POOL 71 n TENT/CANOPY DESCRIPTION OF WORK: PROPOSED USE: icy HOMEOWNER ASSOC IATI ON/ARCH ITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ %S��i azv� TOTAL AREA: °o S HEATED AREA: o!o46 (Cost of Labor and Materials) PUBLIC SEWER NUMBER OF BEDROOMS: SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS "SEW INTERIOR WALL TYPE: S E WATER TAP: EXTERIOR WALL TYPE: ZE OTHER TAP: TEMP POLE GARAGE TYPE FOUNDATION TYPE bIZE ROOF TYPE: SINGLE a DOUBLE r1 �c-S 12-o L a,tZ_,� !�Sl,iAa 6MP, 4 t iaCILZ TRIPLE F1 ATTACHED F-] DETACHED F] CARPORT SIGNATURE OF APPLICANT: *If proposed work involves new commerci c r or aca a Improvements renovations to an existing commercial property, building elevations are required. // Official Use Only —O% Plans Examiner 1 o nQ 1:; (ter. Zoning Official Comments: ES o NO Fire Marshall Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER Rating n ce i I i ng/roof construction 2nd store wall construction same as first 5/0" Type X drywa 11 on ceiling Min 2x4 wall w/5/0" Type X dr�wa I I ea side to roof 5/s" Type x drywall on ceiling min. 2x full depth blocking or rim joist ea side 2x& wa 11 w/2x4 studs W' o.c. staggered on each side. R-11 Insulation each bay. 5/8" Type X drywall ea side 1 4::,.24 L��� 271 Sp¢ce C4 4L vs J -10 mmmpm� 9 "Wommow OPPWMM qlagowinno � . 70.01Y _ S 4W7 �T 70.06 iBeloc W Z r7"i l,* L��r 6- Z I • af- leu L_5.38 I 51 P.U.E. -.duo~ -64.b3 iai neifie Lone 50R.O.W. N 27' Pavement �.=MOM W."WEN c� N 4818033" W* PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# DATE: 0'l - a � --/� - o '7 BUILDING ADDRESS: /a1 KI►'nvt: Ltj- I. Foundation Requirements NAkO A. Concrete minimum fc of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier 6 mil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior unless over 60' Ion 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated OK II. Framing: Floor, Wall, Ceiling and Roof Requirements A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex N 1. One -hour rated extending to roof deck ENIA4W. E. Header sizes indicated on plans F. Emergency bedroom egress 1. Exit direct to outside 2. O enable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. O enable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Exterior wall covering indicated on plans 2. Sheathing indicated on plans 3. Moisture barrier indicated onlans J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size and spacing and purlin bracing indicated. O. Roof covering used. P. Indicate Wall Bracing Used for Lateral Bracing PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX II. Framing: Floor, Wall, Ceiling and Roof Requirements continued N P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations S. 18" Overhang allowed on zero lot line construction, perforated soffit allowed. T. Protected openings on walls < three feet from propert line OK �- III. Stairway Requirements N A. Stairway Details 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" diff. max. 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8 B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches above handrail 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located four or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four (4) inch sphere IV. Fireplace Requirements (to be indicated onplans) OK A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must extend at least three (3) feet higher than the highest point where it projects through the roof of a building & at least two (2) feet higher than any portion of the building within ten (10) feet horizontal PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX V. Electrical Service Requirements N K A. Electrical plan to include: 1. Electrical fixtures & switches indicated 1-7- 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location VI. Plumbing Requirements N A. Pressure reducing valve required when water pressure exceeds 80 psi B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) Vill. Energy Requirements N K A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 N Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements N Maximum drive width for residence is 25' combined for circular 12' minimum Minimum 20 feet from driveway to side(intersecting) street Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 N(OJV Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 N _ Does not block any water course or divert any flow Elevation certificate needed K c PLANS EXAMINER "APPROVED PLANS PER IRC SECTION R106.3.1." C�1-1(-02 DATEf