HomeMy WebLinkAboutRES2007-00362PREPARED 5/30/07, 7:41:28 INSPECTION TICKET PAGE 6
City ofCollege StationINSPECTOR: BUILDING INSPECTOR DATE----5/29/07
-- -------- ----
ADDRESS . : 121 KLEINE LN SUBDIV: EDELWEISS ESTATES PHS 12
CONTRACTOR B A CATHEY PHONE (979) 255-7064
OWNER . . PHONE
PARCEL . . 24400-1226-0050
APPL NUMBER: 07-00000362 RESIDENTIAL, 2 UNITS NEW (DUPLEX)
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B115 01 3/16/07 OC BLDG, FRAMING TIME: 17:00
3/16/07 AP March 15, 2007 4:02:10 PM glsouth.
B130 01 3/19/07 OC BLDG, INSULATION TIME: 17:00
3/19/07 AP March 19, 2007 8:46:38 AM ncochran.
B125 01 5/25/07 RH BLDG, FINAL TIME: 17:00
5/25/07 DP May 24, 2007 3:18:20 PM acarter.
05/25/2007 11:43 AM RH PDA
Need to install landscaping. Need to block ridge vent
between units. Address meter cans.
3125 02 V30BLDG, 100
101 AP O C May29, 2007 1:40:43PMkwolfe.
r
----------------------------------- COMMENTS AND NOTES
r 1_ ti2c�
i2-
-;p,n r �✓�g�h
G�
a 6/5/2007 Gina Southerland - Re: Calling for C.O. 121 Kleine Ln. Page 1
From:
To:
Date:
Subject:
THIS ONE IS OK. JMG
Joe Garcia
Benjamin McCarty;
6/1/2007 3:15 PM
Re: Calling for C.O
>>> Gina Southerland 05/25/07 8:11 AM >>>
BP# 07-362
Gina Southerland
CSR - Planning & Development Services
City of College Station
979-764-3570
www.cstx.gov
Chris Haver; Gina Southerland; Kim Wolfe; Mitchell...
121 Kleine Ln.
WF0873917 /
001
City of College
Station
PAGE 1
REQ. DATE:
02/13/07
02/13/07
15:45:22
LOCATION:
121 KLEINE
LN
LOC ID:
207994
REQUESTOR:
B A CATHEY
ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE
AUTH. USER:
KWOLFE
WORK TYPE:
ROUT
TEMP POLE
PASSED
********************************************************************************
TASK:
SET UP NEW
UTILITY ACCT
SET
READY
SCHED START:
02/13/07
SCHED
COMPLETION:
02/13/07
********************************************************************************
JOB ORDER RESULT COMMENTS 2
c
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
Property Address . . . . . .
Property ID:
R #•
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
Owner
------------------------
07-00000362 Date 2/19/07
121 KLEINE LN
24400-1226-0050
RESIDENTIAL, 2 UNITS NEW (DUPLEX)
EDELWEISS ESTATES PHS 12
RESIDENTIAL
DUPLEX RESIDENTIAL
156222
Contractor
B A CATHEY
PO BOX 9517
COLLEGE STATION TX 77842
(979) 255-7064
--- Structure Information
000 000 DUPLEX
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
TYPE OF GARAGE (ATT/DET)
NA
HEATED AREA
2630.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
6.00
NUMBER OF BEDROOMS
6.00
SEWER TYPE
PUBLIC
TAZ
405.00
----------------------------
Permit . . . . . .
-----------------------------------------------
BUILDING PERMIT
Additional desc . .
NC
Permit Fee . . . .
631.00 Plan Check Fee
.00
Issue Date . . . .
2/19/07 Valuation . .
. . 156222
Expiration Date . .
8/18/07
Qty Unit Charge Per Extension
BASE FEE 460.00
57.00 3.0000 THOU BLDG, VAL 100001-500000 171.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
-------- ----- X
BUILDING DEP R PRESENTATIVE:
APPLICANT: IV
?: BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 07-00000362
Page 2
Date 2/19/07
Special Notes and Comments
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
1 HOUR DUPLEX SEPERATION WALL MUST BE MAINTAINED FROM FLOOR
TO ROOF DECKING. ALL PENETRATIONS MUST BE PROPERLY
ADDRESSED AND MAINTAINED.
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
------------------- ----- -- ---- ------------
RESENTATIVE:
BUILDING DEPT
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 07-00000362
Page 3
Date 2/19/07
Special Notes and Comments
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
BUILDING DEPT RESENTATIVE:
APPLICANT:
BUILDING PERMIT '
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page 4
Application Number . . . . . 07-00000362 Date 2/19/07
----------------------------------------------------------------------------
Special Notes and Comments
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
Narrow Wall Bracing Fully Sheathed
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
---------------------------------------------------------
Permit Fee Total 631.00 631.00 .00 .00
Plan Check Total .00 .00 .00 .00
Grand Total 631.00 631.00 .00 .00
-
APPLICANT:
........:....... .....
CITY OF COLLEGE STATION
Planning d' De' t&j q .t Servi ei.
APPLICATION FOR BUILDING PERMIT
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
WWW.CSTX.GOV
For Office Use Only
DATE: SA kd TRCC REG �% J
APPLICATION # v
TEMP POLE #
ADDRESS/LOCATION: /vf,
LOT _ LOCK C�S� �BDIVISION �l��Lui�/S S ��2%.,JS EC/PH
BUSINESS/OWNER NAME: 1�� C--!/ ES PHONE: SZ0 -- 6,r1eOa
CONTRACTOR/HOMEOWNER: '�qA,-46 PHONE:
CONTRACTOR ADDRESS: ?D, &,C -�?S/ q _ „S �r� —%'%
ELECTRICIAN-- �) 'f Jd PLUMBER: �Q-�p Nf �uil�✓/�y► �--
HVAC: : Yl -�5 GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) >dNEW CONSTRUCTION * SLAB ONLY
DUPLEX (Landscape Plans) REMODEL/RENOVATION* SWIMMING POOL
71 n TENT/CANOPY
DESCRIPTION OF WORK:
PROPOSED USE: icy
HOMEOWNER ASSOC IATI ON/ARCH ITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ %S��i azv� TOTAL AREA: °o S HEATED AREA: o!o46
(Cost of Labor and Materials)
PUBLIC SEWER NUMBER OF BEDROOMS:
SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS
"SEW INTERIOR WALL TYPE:
S E
WATER TAP: EXTERIOR WALL TYPE:
ZE
OTHER TAP:
TEMP POLE
GARAGE TYPE
FOUNDATION TYPE
bIZE
ROOF TYPE:
SINGLE a DOUBLE
r1 �c-S 12-o L
a,tZ_,�
!�Sl,iAa
6MP, 4 t iaCILZ
TRIPLE F1
ATTACHED F-] DETACHED F] CARPORT
SIGNATURE OF APPLICANT:
*If proposed work involves new commerci c r or aca a Improvements renovations to an existing
commercial property, building elevations are required.
// Official Use Only
—O%
Plans Examiner
1 o nQ 1:; (ter.
Zoning Official
Comments:
ES o NO
Fire Marshall
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor
R value of ductwork
A/C SEER Rating
n
ce i I i ng/roof
construction
2nd store
wall construction
same as first
5/0" Type X
drywa 11 on
ceiling
Min 2x4 wall
w/5/0" Type
X dr�wa I I ea
side to roof
5/s" Type x
drywall on
ceiling
min. 2x full
depth blocking
or rim joist ea
side
2x& wa 11 w/2x4
studs W' o.c.
staggered on
each side. R-11
Insulation each
bay. 5/8" Type X
drywall ea side
1 4::,.24
L���
271 Sp¢ce
C4
4L
vs J -10
mmmpm� 9 "Wommow OPPWMM
qlagowinno
� .
70.01Y _
S 4W7 �T
70.06
iBeloc
W
Z r7"i l,* L��r 6- Z
I •
af-
leu
L_5.38
I 51 P.U.E.
-.duo~ -64.b3
iai neifie Lone
50R.O.W. N 27' Pavement
�.=MOM W."WEN
c�
N 4818033" W*
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# DATE:
0'l - a � --/� - o '7
BUILDING ADDRESS:
/a1 KI►'nvt: Ltj-
I. Foundation Requirements
NAkO
A. Concrete minimum fc of 3000 PSI
B. Minimum four 4 inch slab thickness
C. Vapor barrier 6 mil. Poly min.
D. Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior unless over 60' Ion
3. Spacing of beams does not exceed 15'
E. Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F. Wood foundation details indicated
OK
II. Framing: Floor, Wall, Ceiling and Roof Requirements
A. Girder or sill dimensions, grade & species
B. Floor joist size, spacing, grade & direction of span indicted on plans
C. Treated sill plate or bottom plate
D. Tenant separation in duplex
N
1. One -hour rated extending to roof deck
ENIA4W.
E. Header sizes indicated on plans
F. Emergency bedroom egress
1. Exit direct to outside
2. O enable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G. O enable bathroom window required when mechanical ventilation is not provided
H. Stud grade andspacing
I. Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated onlans
J. Roof framing Ian or elevation shown
K. Ceiling joist size, spacing, grade and direction of span indicated on plans
L. Attic access location and size indicated on plans
M. Span exceeding code tables must be engineered
N. Rafter size and spacing and purlin bracing indicated.
O. Roof covering used.
P. Indicate Wall Bracing Used for Lateral Bracing
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
II. Framing: Floor, Wall, Ceiling and Roof Requirements continued
N
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
S. 18" Overhang allowed on zero lot line construction, perforated soffit allowed.
T. Protected openings on walls < three feet from propert line
OK
�-
III. Stairway Requirements
N
A. Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" diff. max.
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches above handrail
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located four or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four (4) inch sphere
IV. Fireplace Requirements (to be indicated onplans)
OK
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must extend at least three (3) feet higher than the highest point where it
projects through the roof of a building & at least two (2) feet higher than any portion of the
building within ten (10) feet horizontal
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
V. Electrical Service Requirements
N K
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
1-7-
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
VI. Plumbing Requirements
N
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
Vill. Energy Requirements
N K
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N
Maximum drive width for residence is 25' combined for circular 12' minimum
Minimum 20 feet from driveway to side(intersecting) street
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N(OJV
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
N
_
Does not block any water course or divert any flow
Elevation certificate needed
K
c
PLANS EXAMINER
"APPROVED PLANS PER IRC SECTION R106.3.1."
C�1-1(-02
DATEf