RES2007-00342, 07-409
PREPARED 8/09/07, 11:35:01 INSPECTION TICKET PAGE 3 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 8/09/07 ------------------------------------------------------------------------------------------------ ADDRESS . : 3802 BRIDLE CT SUBDIV: BRIDLE GATE ESTATES PH 2 CONTRACTOR SUMMIT HOMES & DEVELOPMENT PHONE (979) 589-2717 OWNER OAKWOOD CUSTOM HOMES GROUP LTD PHONE PARCEL 159010-0201-0140 APPL NUMBER: 07-00000342 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TY�/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 4/10/07 RH BLDG, FOUNDATION -SLAB TIME: 17:00 4/10/07 AP April 9, 2007 2:21:40 PM kwolfe. 04/10/2007 10:24 AM RH PDA Strings up, slab ground installed. B115 01 5/08/07 RH BLDG, FRAMING TIME: 17:00 5/08/07 AP May 8, 2007 8:46:43 AM kwolfe. May 8, 2007 4:51:08 PM glsouth. May 8, 2007 4:51:12 PM glsouth. B130 01 5/08/07 RH BLDG, INSULATION TIME: 17:00 5/08/07 AP May 8, 2007 8:46:52 AM kwolfe. he called both in May 8, 2007 4:50:54 PM glsouth. B125 01 8/09/07 k BLDG, FINAL TIME: 17:00 August 9, 2007 9:27:56 AM kwolfe. -------------------------------------- COMMENTS AND NOTES -------------------------------------- Date: 8/9/2007 Inspection Comments for Finals Permit Year: 7 Permit Number: 342 Address: 3802 BRIDLE CT Ins.Type Inspection Type Code Description Status Inspection Result Comments B100 BLDG, FOUNDATION -SLAB IC 04/10/2007 10:24 AM RH PDA B100 BLDG, FOUNDATION -SLAB IC Strings up, slab ground installed. B115 BLDG, FRAMING IC May 8, 2007 4:51:12 PM glsouth. B130 BLDG, INSULATION IC May 8, 2007 4:50:54 PM glsouth. E150 ELEC, FINAL IC 07/31/2007 02:54 PM OC PDA E150 ELEC, FINAL IC masterbed not working . closet lights too close to E150 ELEC, FINAL IC shelfs.install doorbell. M110 MECH, FINAL IC 08/02/2007 02:42 PM RH PDA M110 MECH, FINAL IC Need damper on dryer duct and seal around furnace flue to M110 MECH, FINAL IC prevent wate leaks by building final. Page 1 WFO875374 / 001 City of College Station PAGE 1 REQ. DATE: 02/20/07 02/20/07 11:27:09 LOCATION: 3802 BRIDLE CT LOC ID: 200606 REQUESTOR: SUMMIT HOMES ORIGIN: CUSTOMER -WALK IN REQ. USER: GLSOUTH AUTH. USER: GLSOUTH WORK TYPE: ROUT SWR 4" WTR 3/4" ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 02/20/07 SCHED COMPLETION: 02/20/07 ******************************************************************************** JOB ORDER RESULT COMYM TTI'S PROPOSED / RESIDENCE ao TWO CAR GARAGE. S N 42051'28" W 80.94' ---- - - 1_0�_P.U_E_ __------- - - 120' ETBAC ' • N a a I I i I I I I � II I I I I I I I I II ! II ui II I{{ 15" 43" I� � O � I QI ° col 4 Z I NI � ` �?I I`I I I L I� I I I 14'141" ' I IY W U- la 'NLf) I� ILu NCO �U �L�, o.r IZ i I I /V r\kj I ' CONC. DRIVE ' NC ° C ASHOUT HERE— \ °� i 50' \� R®IMA1 r_'ATC E LOT - 14 BLOCK - 1 r, A-6 SHEET six [.Er-BLMOUr 1-1am CHARLES JOHNSON 281-543-2045 JOB# 07-006 PLAN# 1772� DESIGNS, INC. (877) 690-CADD `'-`'";' 4500 Carter Creek Dr. #203 Bryan, TX 77802 www.raidesigns.eoil ym-mmul BD 1-i9-m LEr-r�MHOUr 1-2s-M of 25� BUILDING PER P IT CITY OF COLIA4e TAT ION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX:. (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 07-00000342 Date 2/20/07 Property Address . . . . . . 3802 BRIDLE CT Property ID: 159010-0201-0140 R #: R300294 Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . BRIDLE GATE ESTATES PH 2 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 120000 Owner Contractor ------------------------ OAKWOOD CUSTOM HOMES ------------------------ GROUP LTD SUMMIT HOMES & DEVELOPMENT 4012 SH 6 S 12200 WICKSON LAKE RD COLLEGE STATION TX 77845 BRYAN TX 77808 (979) 589-2717 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1772.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC TAZ 405.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . GS Permit Fee . . . . 520.00 Plan Check Fee .00 Issue Date . . . . 2/20/07 Valuation 120000 Expiration Date . . 8/19/07 Qty Unit Charge Per Extension BASE FEE 460.00 20.00 3.0000 THOU BLDG, VAL 100001-500000 60.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS OPENING INIM ROUGH-FRAMED.SIZE 22" ------------------------------�------------------------ BUILDING DEPT_-REi$RESEI TATIVE : _ APPLICANT: BUILDING PERMIT CITY OF COLLAGE rATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 07-00000342 Page 2 Date 2/20/07 Special Notes and Comments X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12' ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOW S ARE REQUIRED THESE ----------------TIV-------- ---------/��----------- BUILDING-DEPT-RE�.-- R§---EN f�A --------E APPLICANT: BUILDING PERMIT CITY OF COLIk GE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 3 Application Number . . . . . 07-00000342 Date 2/20/07 ---------------------------------------------------------------------------- Special Notes and Comments ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WI..E 60" JOVE DRATN SHALL BE -----------------------------Z--- - - - - - - BUILDING APPLICANT: S]ENTATIVE : BUILDING PERMIT CITY OF COLL:SGE 34TATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 4 Application Number . . . . . 07-00000342 Date 2/20/07 ---------------------------------------------------------------------------- Special Notes and Comments TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND CLOTHES DRYERS. Narrow Wall Bracing Fully -Sheathed with 18" APA garage bracing, Modified Dining area per plans and Interior anchoring and bracing at front door area. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ------------------------------ --------------------------- Permit Fee Total 520.00 520.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1270.00 1270.00 .00 .00 -------------------------------------------- ---- '--------- BUILDING DE SENTAT e. APPLICANT: TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 07-00000409 Date 2/20/07 Property Address . . . . . . 3802 BRIDLE CT Property ID: 159010-0201-0140 R #: R300294 Application type description TEMP POLE Subdivision Name . . . . . . BRIDLE GATE ESTATES PH 2 Property Use . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation 0 Owner Contractor ------------------------ OAKWOOD CUSTOM HOMES GROUP LTD ------------------------ SUMMIT HOMES & DEVELOPMENT 4012 SH 6 S 12200 WICKSON LAKE RD COLLEGE STATION TX 77845 BRYAN TX 77808 (979) 589-2717 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . GS Permit Fee . . . . 20.00 Issue Date . . . . 2/20/07 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary Charged ---------- Paid Credited ------------------------------ Due ----------------- Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 ---------------------------- BUILDING D&P'I'-2E-1kRE$ APPLICANT? CITY OF COLLEGE STATION Plann'ing c�,Deve%pinen(ScivireJ. ADDRESS/LOCATION: LOT l L BLOCK APPLICATION FOR BUILDING PERMIT 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX WWW.CSTX.GOV 3 6 0 a 73RIIII, G7 � For OM e Use Only DATE: TRCC RE (G� n APPLICATION'# —.*I; TEMP POLE # SUBDIVISION Q SL-0 6- C A=1' G- / SEC/PH I�l BUSINESS/OWNER NAME: :�tj tn. liu I i^���' 1 PHONE: g2�9.22 q y'OCID CONTRACTOR/HOMEOWNER: C11A a.C,_s PHONE: 9°)9 - r224 - -? C1 0 CONTRACTOR ADDRESS: _ kA oZ Q <3 L.() a G [C SIG A) 1— iC e N 7775c'30 ELECTRICIAN: I91t') 64--t Ll�.J PLUMBER: C ? PLUM G.,, ', HVAC: )6p jtA.1 c4,eg, A4 L- A+2co.,,A.Y%GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ONLY DUPLEX (Landscape Plans) REMODEL/RENOVATION* SWIMMING POOL TENT/CANOPY DESCRIPTION OF WORK: L_ _ PROPOSED USE: Z m_ HOMEOWNER ASSOC IATI ON/ARCH ITECTUAL. OR DESIGN REVIEW COMMITTEE APPROVAL: • TEXAS ACCESSIBILITY_S_T_ANnAP-n-_l_T_nc'—n.OJECT REGISTRATION# EABPRJ lr6VV VALUATION: $ 4-1-Ah, AREA: �S'� HEATEDAREA:�'aoor andTMaterials) _TOTAL PUBLIC SEWER NUMBER OF BEDROOMS: SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: o� dSEWER TAP: INTERIOR WALL TYPE: 54-e_'r- O P-0c L< IZE dWATER TAP: 3 A EXTERIOR WALL TYPE: SIZE OTHER TAP: FOUNDATION TYPE: C. -C,4C SIZE E�rTEMP POLE RODF TYPE: 1.�c:• L P v Y.)V� hh/��� GARAGE TYPE: SINGLE a DOUBL� TRIPLE a ATTACHED jjj�L DETA�HED [Z] CARPORT a SIGNATURE OF APPLICANT: *.If proposed work involves new commercial construct' or facade improvements/renovations to an ting commercial property, building elevations are required Official Use Only 2 - / S- ---b? Plans Examiner 4".js Wt ii Zoning Official Comments: 0r NO Fire Marshall Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER Rating -16 � /3 �/ f PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# '-7 _ 3y� BUILDING ADDRESS: 380a 3A A'Al�e cam. I. Foundation Requirements N K A. Concrete minimum fc of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier 6 mil. Poly min. N D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior unless over 60' Ion 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated OK II. Framing: Floor, Wall, Ceiling and Roof Requirements NA/OV A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex K 1. One -hour rated extending to roof deck OK E. Header sizes indicated on plans F. Emergency bedroom egress 1. Exit direct to outside 2. O enable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. O enable bathroom window required when mechanical ventilation is not rovided H. Stud grade andspacing I. Exterior wall details 1. Exterior wall covering indicated on plans 2. Sheathing indicated on plans 3. Moisture barrier indicated on plans - J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans M. N. O. P. Span exceeding code tables must be engineered Rafter size and spacing and purlin bracing indicated. Roof covering used. Indicate Wall Bracing Used for Lateral Bracing PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX II. Framing: Floor, Wall, Ceiling and Roof Requirements continued N P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations S. 18" Overhang allowed on zero lot line construction, perforated soffit allowed. T. Protected openings on walls < three feet from property line &OK III. Stairway Requirements OK A. Stairway Details 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" diff. max. 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8 B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches above handrail 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards,required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located four or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four (4) inch sphere IV. Fireplace Requirements (to be indicated on plans) OK A. Hearth extensions 1. Fireplace opening < 6 sq., ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must extend at least three (3) feet higher than the highest point where it projects through the roof of a building & at least two (2) feet higher than any portion of the building within ten (10) feet horizontal PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX V. Electrical Service Requirements N A. Electrical plan to include: 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location VI. Plumbing Requirements N A. Pressure reducing valve required when water pressure exceeds 80 psi B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required)1 VIII. Energy Requirements N A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 NA/ Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements NA/ Maximum drive width for residence is 25' combined for circular 12' minimum Minimum 20 feet from driveway to side(intersecting) street Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 N Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 NA% Does not block any water course or divert any flow Elevation certificate needed K 7 P ANS EXAMINER "APPROVED PLANS PER IRC SECTION R106.3.1." Z -<S-07 DATE Perttut # Permit Date REScheck Software Version 3.7.3 Compliance Certificate Project Title. 1772 Sq. ft. plan Report DOts: 0IM107 Data fdenare: WWob07-006 JohnsonW7-M-rcx Energy Code: 20031ECC Location: Bryan (Bra=$), Texas Construcslon Type= Single FannNy G"ng Arta Percentage: 12% Healing degree Days: 1788 Construction Site: Owner/Agard: Designer/Contractor. Summit Homes John Rhodes RAI. Designs, Inc. 9794W6-3366 Maximum sHdC: 0.d0 Your SHGC: 0.40 CdBng is Fiat CeBing or Scissor Truss: 1722 30.0 0.0 80 Wall 1: Wood Fra ne. 16" o.c.: 1T82 ' 13.0 0.0 126 Window 1: Metal Frame:Double Pane with Low-E: 197 O.&M 128 SHGC: 0.40 Door 1: Solid: 39 0.440 17 Door 2: Glass, 18 0.550 10 SHGC: 0.40 Floor 1: Slab-On-GradwUnheatpd: , insulation Depth: 0.0' IN 0.0 2N Furnace 1: Forced Mot Au: 78 AFUE Au Conditioner 1: Electric Central Air: 13 SEER Coremp/kwev SM&ment The proposed building design desated here is consistent with the. building plans, spedftatf4rts, and other calculations submitted with the permit applicatiorL The Proposed building has been designed to meet the 2003 IECC requirements in REScteeck Version 3.7.3 and to comply with the mandato►y requirements listed in the McheO inspection CMe&-fie- tahn %'W 2 Sui,derf0m;igner Company Flame Data 1772 sq- ft. plan Page 1 of 1 90/10 39Vd 99EE-908-6L6 96:60 L003/0E/10 LO m N m Ld (D Q IL LO l LO nm m LO v m i m r` m LO m o-� CO r- (S) m N CO m CD Area Calculator: W indow Area 'total: 197.00 Ill 01129*7 i6A2.01 Area Calculator: Commentel ©� ::: ©�fE3�1■��0 1 11 i E3� �i■i■�ii�i �� �i■i■iii�i �� �i■if�iiii �� �■i�i■��isiii �� �i1�■iiiii �� �i■i■�ii�i �� �i■iliii�i �i �■i!i■�ii�i mi �i■i■iii�i ®i Dili■iii'i mi Dili■iii�i gyp= �i■i■iii�i mi �i■i■iii�i mi �i■i■iii�i �i �i■i■iii�i f�Ii �i■i■iii�i �� �i■iiiii�i �i �i■i■��i�i Door Area Total: 66.56 114 w IL uO m of m r` m m N m fri m Area Calculator: IME ■�1�! fi0■�■� m �■�■ ■�[�! ! ® Ceiling Area Total: 1722.00 1h OS12910716:42;02 LO m LO w a a Area Calculator: © �.■■.�■�■!■r! ■s!! in �.■.!.■i■�l�.m Extarlor Wall ATea Total: 9782.b0 III '.1 ,. LO LO m LO LO m CTI r_ m m CV m m m Area Calculator: Flow Area Total:0.00 111 01IZW0716:42:02 ;WF0877435 / 001 City of College SL-ati'on t PAGE 1 REQ. DATE: 02/27/07 02/27/07 16:31:00 LOCATION: 3802 BRIDLE CT- LOC ID: 200606 REQUESTOR: SUMMIT HOMES AND DEVELOPMENT ORIGIN: CUSTOMER -WALK IN REQ USER: NCOCHRAN AUTH USER:NCOCHRAN WRK TYPE: TEMP POLE PASSED ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 02/27/07 SCHED COMPLETION: 02/27/07 ******************************************************************************** JOB ORDER RESULT COMIENTS / `-� _ 3q 2