PREPARED 6/28/07, 7:25:30 INSPECTION TICKET PAGE 6
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 6/27/07
------------------------------------------------------------------------------------------------
ADDRESS . : 1033 FALLBROOK LOOP SUBDIV: WESTFIELD VILLAGE PH 5
CONTRACTOR STYLECRAFT BUILDERS PHONE (979) 690-1222
OWNER . . PHONE
PARCEL . . 005401-0513-0010
APPL NUMBER: 07-00000331 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 2/22/07 OC BLDG, FOUNDATION -SLAB TIME: 17:00
2/22/07 AP February 21, 2007 1:07:51 PM kwolfe.
Strings On Setbacks O.K.
Slab Ground Installed
B115 01 3/22/07 RH BLDG, FRAMING TIME: 17:00
3/22/07 AE March 21, 2007 5:00:11 PM glsouth.
03/22/2007 04:26 PM RH PDA
Need #2 ceiling joist for master bedroom and closet. Add
blocking for coffered ceiling in master bathroom. Need 3-
16d nails on x brace to plates and 2-8d nails on studs.
Make corrections by insulation inspection.
B130 01 3/26/07 RH BLDG, INSULATION TIME: 17:00
3/26/07 AP March 26, 2007 10:28:51 AM ncochran.
B132 01 3/29/07 RH BLDG, SHEETROCK FASTENER TIME: 17:00
3/29/07 AP March 28, 2007 2:03:01 PM kwolfe.
B125 01 6//s�7/P7 0 BLDG, FINAL TIME: 17:00
61A ! June 27, 2007 2:32:44 PM glsouth.
--,'----------- - COMMENTS AND NOTES --------------
Date: 6/28/2007
Inspection Comments for Finals
Permit Year: 7 Permit Number: 331
Address: 1033 FALLBROOK LOOP
Ins.Type
Inspection Type Code
status
Inspection Result Comments
Description
B100
BLDG, FOUNDATION -SLAB
IC
Strings On Setbacks O.K.
B100
BLDG, FOUNDATION -SLAB
IC
Slab Ground Installed
B115
BLDG, FRAMING
IC
03/22/2007 04:26 PM RH PDA
6115
BLDG, FRAMING
IC
Need #2 ceiling joist for master bedroom and closet. Add
B115
BLDG, FRAMING
IC
blocking for coffered ceiling in master bathroom. Need 3-
B115
BLDG, FRAMING
IC
16d nails on x brace to plates and 2-8d nails on studs.
B115
BLDG, FRAMING
IC
Make corrections by insulation inspection.
Page 1
WF0875149 / 001 City of College Station PAGE 1
REQ. DATE: 02/19/07�"02/19/07 16:47:39
LOCATION: 1033 FALLBROOK LOOP LOC ID: 203940
REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN
REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT
TEMP POLE PASSED
********************************************************************************
TASK:' SET UP NEW UTILITY ACCT SET READY
SCHED START: 02/19/07 SCHED COMPLETION: 02/19/07
********************************************************************************
JOB ORDER RESULT COM ENTS
WFO873721 / 001 -City of College Station
PAGE 1
REQ. DATE:
02/13/07
02/13/07
8:50:15
LOCATION:
1033 FALLBROOK LOOP
LOC ID:
203940
REQUESTOR:
STYLECRAFT BUILDERS ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
GLSOUTH AUTH. USER: GLSOUTH
WORK TYPE:
ROUT
SWR 4"
WTR 3/4"
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT SET
READY
SCHED START:
02/13/07 SCHED COMPLETION:
02/13/07
********************************************************************************
JOB ORDER RESULT COMIENTrS
City of College Station
1101 TEXAS AVENUE ----
COLLEGE STATION TX 77840
C E R T I F I C A T E O F O C C U P A N C Y
P E R M A N E N T
Issue Date . . . . . .
Parcel Number . . . . .
Property Address . . .
Subdivision Name . . .
Legal Description . . .
Property Zoning . . . .
Owner . . . . . . . . .
6/28/07
005401-0513-0010
1033 FALLBROOK LOOP
COLLEGE STATION TX 77845
WESTFIELD VILLAGE PH 5
WESTFIELD VILLAGE PH 5
BLOCK 13 LOT 1
PLANNED DEVL HOUSING
Contractor . . . . . . STYLECRAFT BUILDERS
979 690-1222
Application number 07-00000331 000 000
Description of Work RESIDENTIAL, 1 UNIT DETACHED NEW
Construction type . . . COMBUSTIBLE (UNPROTECTED)
Occupancy type . . . . RESIDENTIAL-SFR/DUPLEX
Flood Zone . . . . . .
Approved
Buil ing Official
VOID UNLESS SIGNED BY BUILDING OFFICIAL
w
6/28/2007) Gina Southerland Re Calling for CO @ 1033 Fallbrook Loop Page 1
From: Terry Boriskie
To: Amber Carter; banderson@stylecraft-builders.com; Benjamin McCarty; Ch...
Date: 6/28/2007 9:36 AM
Subject: Re: Calling for CO @ 1033 Fallbrook Loop
Stylecraft has been notified of the need to raise the water and sewer.
Terry Boriskie
City of College Station
Residential Plans Examiner
979-764-3744
>>> Paul Schoenfeld 6/28/2007 8:43 am >>>
Water needs to be raised.
Sewer buried Flagged.
Paul
>>> Kim Wolfe 6/28/2007 7:51 AM >>>
Any issues?
BP # 07-331
Thanks
Kimberly Wolfe, CPS/CAP
City of College Station
Planning & Development Services
(979)764-3570
www.csbc.00v .
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 FAX: (,979) 764-3496
----------------------------------------------------------------------------
Application Number . . . . . 07-00000331 Date 2/13/07
Property Address . . . . . . 1033 FALLBROOK LOOP
Property ID: 005401-0513-0010
R ## .
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . : . . WESTFIELD VILLAGE PH 5
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . PLANNED DEVL HOUSING
Application valuation 78210
Owner
Contractor
------------------------
------------------------
STYLECRAFT BUILDERS
4090 SH 6 S
COLLEGE STATION
TX 77845
(979) 690-1222
--- Structure Information
000 000 SINGLE FAMILY
Construction Type
COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info
EXTERIOR WALL TYPE
SIDING & BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
1185.00
INTERIOR WALL TYPE
SHEET ROCK
NUMBER OF BATHROOMS
2.00
NUMBER OF BEDROOMS
3.00
SEWER TYPE
SLAB
TAZ
405.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
GS
Permit Fee . . . .
376.00 Plan Check Fee
.00
Issue Date . . . .
2/13/07 Valuation . . .
. 78210
Expiration Date . .
8/12/07
Qty Unit Charge
Per
Extension
BASE FEE
260.00
29.00 4.0000
THOU BLDG, VAL 50001-100000
116.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS
THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL
BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS
OPENING (MINIMUM R UGH -FRAMED SIZE 22"
-------------------------- -----------------------.•-
BUILDING DEPT REPRESENTATIVE:
-----------
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 2
Application Number . . . . . 07-00000331 Date 2/13/07
----------------------------------------------------------------------------
Special Notes and Comments
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH M ASURED AT THE ------------
---------------- ----- ----------------
-------------/C���
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number 07-00000331
Page 3
Date 2/13/07
Special Notes and Comments
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATEP.IAL FROM SLAB AREA
-------------------------------/�J -- - ------- - - - - - - -
BUILDING DEPT REPRESENTATIVE:
APPLI
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page
4
Application Number . . . . . 07-00000331 Date
2/13/07
----------------------------------------------------------------------------
Special Notes and Comments
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND
CLOTHES DRYERS.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
------------------------------
---------------------------
Permit Fee Total 376.00 376.00 .00
.00
Plan Check Total .00 .00 .00
.00
Other Fee Total 750.00 750.00 .00
.00
Grand Total 1126.00 1126.00 .00
.00
---------------------
------- ------ ----- -'-----------
BUILDING DEPT REPRESENTATIVE:
APPLICANT�f
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
07-00000332 Date
2/13/07
Property Address
. . . . . .
1033 FALLBROOK LOOP
Property ID:
005401-0513-0010
Application type
description
TEMP POLE
Subdivision Name
. . . . . .
WESTFIELD VILLAGE PH 5
Property Use . .
. . . . . .
RESIDENTIAL
Property Zoning .
. . . . . .
PLANNED DEVL HOUSING
Application valuation
. . . .
0
Owner
Contractor
------------------------
------------------------
STYLECRAFT BUILDERS
4090 SH 6 S
COLLEGE STATION
TX 77845
(979) 690-1222
----------------------------------------------------------------------------
Permit . . . . .
. TEMP POLE
PERMIT
Additional desc
GS
Permit Fee . . .
. 20.00
Issue Date . . .
. 2/13/07
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary
Charged
----------
Paid Credited
------------------------------
Due
-----------------
Permit Fee Total
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
_ APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
CTTYOF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX
Planning&Darkpm=t&micer WWW.CSTX.GOV
For OFize use ey
C;2�L���Q�
DATE: TR C REG
I'X
APPLICATION # 2
TEMP POLE # C)
ADDRESS/LOCATION: (b33 F>4 L L-��2Q0 �C LOO P
LOT I `/BLOCK 1.3 SUBDIVISION W t:STC -I IF- L D V \ 1- LAC -I E_ SEC/PH
5 -/
BUSINESS/OWNER NAME:" STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext.120
CONTRACTORIHOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120
CONTRACTOR ADDRESS: 4090 State Highwav 6 South
ELECTRICIAN: Brazos Valley Electric PLUMBER: Bass Plumbing
HVAC: Control Tema GOOD CENTS (Residential only): No
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) H
NEW CONSTRUCTION * SLAB ONLY
DUPLEX (Landscape Plans REMODEURENOVATION* SWIMMING POOL
Required)
DESCRIPTION OF WORK: Conventional Framing
STRUCTURE USE: Single Familv Residence
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: N/,A_
TEXAS ACCESSIBILITY STANDAR -(TAS) PROJECT REGISTRATION# EABPRJ N/A
VALUATION: $_-7 8 2-C - TOTAL AREA: J (, 2 -I HEATED AREA: 1 5
(Cost of Labor and Materials)
�/I(p QX PUBLIC SEWER
II SEPTIC/TREATMENT SYSTEM
pQX SEWER TAP: 4°
SIZE
��✓✓ FX WATER TAP: %4"
SIZE
( OTHER TAP:
W� TEMP POLE
\ GARAGE TYPE:
SIZE
NUMBER OF BEDROOMS: 3
NUMBER OF BATHROOMS: a
INTERIOR WALL TYPE: Sheet Rock
EXTERIOR WALL TYPE: Siding and/or Masonry
FOUNDATION TYPE: Slab on Grade
ROOF TYPE: Composition
SINGLE F__j DOUBLE 0 TRIPLE
ATTACHED FX DETACHED F_'� CARPORT
SIGNATURE OF APPLICANT. _t�� 12 • CSgiv_�" For Stylecraft
*If proposed work involves new commercialLcbrIstruction or facade improvements/renovations to an existing
commercial property, building elevations are required.
000000ee0000eooe000_oo.0000000000000eoe0000000e000000000000000
Official Use Only
�-°Aoek Lot Plans Eominer
GAAA,,o 01+ En jjA19eReJ /3e0.c i4g
Zoning Official
ents:
YES Or NO
Energy Code Compliance Information
% Glazing of exterior walls
%
.
/
Insulation R value of exterior walls
R13
Insulation R value of ceiling 1 (flat areas).
R30
Insulation R value of ceiling 2 (vaulted areas/no attic)
R19
Glazing SHGC
.40
Glazing U-Factor
.65
R value of ductwork
R6
A/C SEER. Rating
13
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# 0'7 _ 3 3 I DATE: �2 _ 8-0
BUILDING ADDRESS:
/D 3 3 �ig-lI.b2ooe-
I. Foundation Requirements
N
A. Concrete minimum f'c of 3000 PSI
B. Minimum four 4 inch slab thickness
C. Vapor barrier 6 mil. Poly min.
D. Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior unless over 60' Ion
3. Spacing of beams does not exceed 15'
E. Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F. Wood foundation details indicated
OK
II. Framing: Floor, Wall, Ceiling and Roof Requirements
A/
A. Girder or sill dimensions, grade & species
B. Floor joist size, spacing, grade & direction of span indicted on plans
C. Treated sill plate or bottom plate
D. Tenant separation in duplex
OK
1. One -hour rated extending to roof deck
WOK
E. Header sizes indicated on plans
rV
F. Emergency bedroom egress
1. Exit direct to outside
2. O enable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G. O enable bathroom window required when mechanical ventilation is not provided
H. Stud grade andspacing
I. Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J. Roof framing Ian or elevation shown
K. Ceiling joist size, spacing, grade and direction of span indicated on plans
L. Attic access location and size indicated on plans
M. Span exceeding code tables must be engineered
N. Rafter size and spacing and purlin bracing indicated.
O. Roof covering used.
P. Indicate Wall Bracing Used for Lateral Bracing
e
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
II. Framing:
Floor, Wall, Ceiling and Roof Requirements continued
NA/,OK)
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
S.
T.
18" Overhang allowed on zero lot line construction, perforated soffit allowed.
Protected openings on walls < three feet from property line
OK
III. Stairway Requirements
OK
A.
Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" diff. max.
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B.
Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C.
Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches above handrail
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D.
Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located four or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairwa
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four (4) inch sphere
IV. Fireplace Requirements (to be indicated onplans)
OK
A.
Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B.
Masonry fireplace requires 2" clearance from all combustible materials
C.
Chimneys must extend at least three (3) feet higher than the highest point where it
projects through the roof of a building & at least two (2) feet higher than any portion of the
building within ten (10) feet horizontal
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
V. Electrical Service Requirements
N
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
VI. Plumbing Requirements
NA/
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N K
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
Vill. Energy Requirements
iV
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window LI-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N
Maximum drive width for residence is 25' combined for circular 12' minimum
Minimum 20 feet from driveway to side(intersecting) street
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N K
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
NAB
Does not block any water course or divert any flow
Elevation certificate needed
K
JIA"- _�)
2-7,0
PLANS EXAMINER DATE
"APPROVED PLANS PER IRC SECTION R106,3.1."
/ Permit #
Permit Date
REScheck Software Version 3.7.3
Compliance Certificate
Project Title: Plan # 1185-WVCO
Report Date: 02/06/07
Data filename: S:\ACAD\Archived\Old REScheck\1 1851033 Fallbrook.rck
Energy Code: 2000 IECC
Location: College Station, Texas
Construction Type: Single Family
Glazing Area Percentage: 11%
Heating Degree Days: 1788
Construction Site: Owner/Agent: Designer/Contractor:
Permit Date: 02-06-2007 ,
Maximum SHGC: 0.40 Your SHGC: 0.40
Ceiling 1: Flat Ceiling or Scissor Truss:
999 30.0
0.0
35
Ceiling 2: Cathedral Ceiling (no attic):
186 19.0
0.0
10
Wall 1: Wood Frame, 16" o.c.:
1192 13.6
0.0
84
Window 1: Metal Frame, Double Pane with Low-E:
112
0.670
75
SHGC: 0.40
Door 1: Solid:
38
0.500
19
Door 2: Glass:
18
0.440
8
SHGC: 0.40
Floor 1: Slab-On-Grade:Unheated: , Insulation Depth: 0.0'
149
0.0
155
Air Conditioner 2: Electric Central Air: 13 SEER
Furnace 2: Forced Hot Air: 80 AFUE
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in
REScheck Version 3.7.3 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
K ECPAFT FU1LPF-42S,11 C- Z -00
Builder/Des er Company Name Date
Project Notes:
Previously saved project information:
Spec
1033 Fallbrook Loop
College Station, Texas
Stylecraft Builders, Inc.
4090 St. Hwy. 6 S.
College Station, Texas 77845
Plan # 1185-WVCO Page 1 of 1