HomeMy WebLinkAboutRES2007-00320, 07-32107.3do'
O'1.3011.
From: Tern/Borskie
To: Amber Carter; Benjamin McCarty; Chris Have, Gina Southedand; Joe G—
Date: 8/1/20073:39PM
Subject: Re: Calling forCl}. @ 2715 Horse HaveU Ln.
Notified Johnny with Oakwood Homes at412-37]D
TerryBmiskie
City ofCollege Station
Residential Plans Examiner
979'764'3744
> > > Paul Schoenfeld7/33:51 p0 >>:"
Wateruk
Sewer buried flagged and painted.
Paul
»> > Gina Southedand78O/ZVO7 11:58Aw > > >
Gina Somherland
{Sa Planning & Development Services
City o[College Station
979'764+3570
u��b(.aov
Inspection Inquiry - City of College Station
Inspection Inquiry
Property ID: 336300.0201-0080
Property address: 2715 HORSE HAVEN LN
Application, structure number. 07 00000320 000 000
Permit type, sequence number. BLDG 00 BUILDING PERMIT
Home 1 Now Window I Support
t:111oli 1 1 Help
Inspection type, sequence number. 6125 0001 BLDG, FINAL
Inspection status, date: INSPECTION COMPLETED 7/24/07
Requested date, time, by: 7/20/07 17:00 AC
Override date, time, by:
User ID to request, result: ACARTER GLSOUTH
Phone Interface number. 1069335
Inspector assigned: JGM JOHN MALDONADO
Results status, date: APPROVED 7/n0/07
Final Inspection flag: Y
Penalty amount•. .00
JJuly 20, 2007 12:34:05 PM acarter.
.................. ......... _._..._....._... ............. ............. .._....................... _....... _... _.... _........ .._................... _.......... _................................... ................. ............
.._=_
c _
WF0873174 / 001 City of College Stat.ort '
PAGE 1
REQ. DATE:
02/09/07
02/09/07
14:06:27
LOCATION:
2715 HORSE HAVEN LN
LOC ID:
205424
REQUESTOR:
OAKWOOD CUSTOM HOMES ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
GLSOUTH AUTH. USER: GLSOUTH
WORK TYPE:
ROUT
SWR
4" WTR 3/411
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT SET
READY
SCHED START: 02/09/07 SCHED COMPLETION:
02/09/07
********************************************************************************
JOB ORDER
RESULT COMMENTS
N25'15'38"E , 51.29'
51.29
ap 58 5' U . .
mC0 � LOT 8 --] 'C VICO CD
0.14 acres iO �iw
(O
� D7
310 — 3-' 1 312 Z
�2 —g"
O?
—114„
5
2'M 0
2
�25, —0
�
55.00,
5 g' 45 53„
W N
2715 HORSE HAVEN LANE
LOT:
8
BLOCK:
1
SECTION:
2
IIORSEIIAVEN
ESTATES
COLLEGE STATION, TEXAS
BUILDER:
SITE
PLAN
OD CUSTOM
IIOMES GROUP LTD. SCALE:
1"-20'
iNigHHB-2715-HHL-SEABISQIITjbW_I.dwg, Model, 02/06/2007 04:23:42 PM,
Letter, 1:240
BUILbI-NG-`PERMZ,'t'• ,xti
CITY OF COLLEGE STATION
1101 TEXAS'.'A7�..
COLLEGE STATION, TX 77840'
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 07-00000320 Date 2/09/07
Property Address . . . . . . 2715 HORSE HAVEN LN
Property ID: 336300-0201-0080
R #: R304745
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . HORSE HAVEN PH 2
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 105006
Owner Contractor
------------------------ ------------------------
OAKWOOD CUSTOM HOMES GROUP LTD OAKWOOD CUSTOM HOMES
4012 SH 6 S 4060 SH 6 S
COLLEGE STATION TX 77845 COLLEGE STATION TX 77845
(979) 690-1504
--- Structure Information 000 000 SINGLE FAMILY
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info . . . . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 1591.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 2.00
NUMBER OF BEDROOMS 4.00
SEWER TYPE PUBLIC
TAZ 225.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . . NC
Permit Fee . . . . 478.00 Plan Check Fee .00
Issue Date . . . . 2/09/07 Valuation . . . . 105006
Expiration Date . . 8/08/07
Qty Unit Charge Per Extension
BASE FEE 460.00
6.00 3.0000 THOU BLDG, VAL 100001-500000 18.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 2211
--------------------------- - ----------
BUILDING DEPT R RESENTATIVE:
/111 A , e-, a '#
APPLICANT:
BUILDING °PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 FAX: (979) 764-3496
Page 2
Application Number . . . . . 07-00000320 Date 2/09/07
----------------------------------------------------------------------------
Special Notes and Comments
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
Garage ceiling must have 5/8" Type X sheetrock when there
is Habitable space above the garage.
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 121
----------------------------- ----- _ --------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING 'PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 3
Application Number . . . . . 07-00000320 Date 2/09/07
----------------------------------------------------------------------------
Special Notes and Comments
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
------------------------------------ A~ 460P -------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING`PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page
4
Application Number . . . . . 07-00000320 Date
2/09/07
----------------------------------------------------------------------------
Special Notes and Comments
VEGETATION AND FOREIGN MATERIAL.
STAIRS SHALL COMPLY WITH SECTION R-311 (2003 IRC) WITH A
CONTINUOUS HANDRAIL OR SECTION
1009 (2003 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL
NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A
NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND
LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003
IRC)
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND
CLOTHES DRYERS.
Narrow Wall Bracing Fully Sheathed.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
------------------------------
---------------------------
Permit Fee Total 478.00 478.00 .00
.00
Plan Check Total .00 .00 .00
.00
Other Fee Total 750.00 750.00 .00
.00
Grand Total 1228.00 1228.00 .00
.00
-------------------------- ------ - - - '------------
BUILDING DEPT REPRESENTATIVE: -
APPLICANT:
TEMPORARY POLE PERMITr
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
07-00000321 Date
2/09/07
Property Address . . . . . .
2715 HORSE HAVEN LN
Property ID:
336300-0201-0080
Application type description
TEMP POLE
Subdivision Name . . . . . .
HORSE HAVEN PH 2
Property Use . . . . . . . .
RESIDENTIAL
Property Zoning . . . . . . .
SINGLE FAMILY RESIDENTIAL
Application valuation . . . .
0
Owner
Contractor
------------------------
OAKWOOD CUSTOM HOMES GROUP LTD
------------------------
OAKWOOD CUSTOM HOMES
4012 SH 6 S
4060 SH 6 S
COLLEGE STATION TX 77845
COLLEGE STATION
TX 77845
(979) 690-1504
----------------------------------------------------------------------------
Permit . . . . . . TEMP POLE
PERMIT
Additional desc . . NC
Permit Fee . . . . 20.00
Issue Date . . . . 2/09/07
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . . . . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary Charged
----------
Paid Credited
------------------------------
Due
-----------------
Permit Fee Total 20.00
20.00 .00
.00
Other Fee Total 45.00
45.00 .00
.00
Grand Total 65.00
65.00 .00
.00
-------------------------------------------- ----- ------------------
BUILDING DEPT PAPRESENTATIVE:
APPLICANT:
t APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
- ` 1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX
Planning & Development, &—ica
WWW.CSTX.GOV
aA
se Only
DATE:RCC REG
APPLICATION # M--31910
TEMP POLE # in
ADDRESS/LOCATION: 2715 HORSE HAVEN LANE '✓
LOT 8 BLOCK 1 ✓SUBDIVISION HORSE HAVEN ESTATES`'
SEC/PH 2 ,/
BUSINESS/OWNER NAME: ALTON OFCZARZAK
PHONE 979-690-1504
CONTRACTOR/HOMEOWNER: OAKWOOD CUSTOM HOMEBUILDERS PHONE:979-690-1504
CONTRACTOR ADDRESS: 4060 HIGHWAY 6 SOUTH COLLEGE STATION, TEXAS 77845
ELECTRICIAN: CAMPISE ELECTRIC
HVAC: THREE RIVERS
PLUMBER: AGGILAND PLUMBING
_ GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION * SLAB ONLY
DUPLEX (Landscape Plans REMODEURENOVATION* SWIMMING POOL
Required)
DESCRIPTION OF WORK: NEW CONSTRUCTION
STRUCTURE USE: SINGLE FAMILY RESIDENTIAL
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESS11, I T NDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ ' TOTAL AREA: 2103 _ HEATED AREA: 1591
(Cost of tabor and Materials)
FX PUBLIC SEWER
SEPTIC/TREATMENT SYSTEM
NUMBER OF BEDROOMS: 4
NUMBER OF BATHROOMS: 2.5
OX SEWER TAP: 4"
INTERIOR WALL TYPE:
SIZE
QX WATER TAP: 3/a
EXTERIOR WALL TYPE:
SIZE
a OTHER TAP:
FOUNDATION TYPE:
SIZE
- �X TEMP POLE
ROOF TYPE:
2X4 @ 16 W/ BRICK
SLAB & BEAM
25 YR COMP.
GARAGE TYPE: SINGLE. F] DOUBLE FX TRIPLE F7
ATTACHED FX DETACHED F_� CARPORT
SIGNATURE OF APPLICANT:
*If proposed work involves new commercial construction or facade improvements/renovations to an existing
commercial property, building elevations are required.
Official Use Only
�J Co ments:
NO
Plans Examiner
Zoning Official
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vault
Glazing SHGC
Glazing U-Factor
R value of ductwork
A/C SEER Rating
7%
R13
M
� j.
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# 07 - 3.2v DATE: -r7
�-ga
BUILDING ADDRESS: 62%/s
PO a 5-e 14AVe,,l Z� -
I. Foundation Requirements
NA/
A.
Concrete minimum f'c of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier 6 mil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior unless over 60' Ion
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F.
Wood foundation details indicated
p
II. Framing:
Floor, Wall, Ceiling and Roof Requirements
N
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
OK
1. One -hour rated extending to roof deck
CgUOK
E.
Header sizes indicated on plans
F.
Emergency bedroom egress
1. Exit direct to outside
2. O enable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
O enable bathroom window required when mechanical ventilation is not provided
J
H.
Stud grade andspacing
I.
Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, rade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
N.
O.
P.
Span exceeding code tables must be engineered
Rafter size and spacing and purlin bracing indicated.
Roof covering used.
Indicate Wall Bracing Used for Lateral Bracing
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
II. Framing: Floor, Wall, Ceiling and Roof Requirements continued
N
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
S. 18" Overhang allowed on zero lot line construction, perforated soffit allowed.
T. Protected openings on walls < three feet from property line
OK
III. Stairway Requirements
N
A. Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" diff. max.
4. Stairway width not less than 36 inches
j
5. Stairway headroom not less that six ft. eight 6-8
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
j
I
C. Spiral stairway details
I
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches above handrail
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located four or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four (4) inch sphere
IV. Fireplace Requirements (to be indicated on cans)
QNQD K
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must extend at least three (3) feet higher than the highest point where it
projects through the roof of a building & at least two (2) feet higher than any portion of the
building within ten (10) feet horizontal
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
V. Electrical Service Requirements
NA/
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
VI. Plumbing Requirements
N
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
NA/
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
NA/ K
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements - Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N
Maximum drive width for residence is 25' combined for circular 12' minimum
Minimum 20 feet from driveway to side(intersecting) street
Driveway access to lesser street for corner lots
Subdivision Regulations - Ordinance 690
NqI O
Approved subdivision
Plat filed
Flood lain Regulations - Ordinance 1301
NA/0
Does not block any water course or divert any flow
Elevation certificate needed
OK
v -
zm�J-' -s-Dl
'PLAtIfS EXAMINER DATE
"APPROVED PLANS PER IRC SECTION R106.3.1."
Permit #
Permit Date
0 N REScheck Software Version 3.7.3
Compliance Certificate
Project Title: HORSEHAVEN LOT 8, BLK 1, PH2
Report Date: 02/06/07
Data filename: G:IOAK DWG\HORSEH-3kSEASIS-1\HH5-27-1.RCK
Energy Code:
2003 IECC
Location:
College Station, Texas
Construction Type:
Single Family
Glazing Area Percentage:
7%
Heating Degree Days:
1788
Construction Site:
Owner/Agent:
Designer/Contractor:
2715 HORSEHAVEN LANE
ALTON OFCZARZAK
David Park
College Sataion, TX 77845
OAKWOOD CUSTOM HOMES GROUP
OAKWOOD CUSTOM HOMES GROUP
LTD.
LTD. HOME PLAN DESIGN SERVICE
4060 HWY. 6 SOUTH
4060 Highway 6 South
COLLEGE STATION, TX 77845
College Station, TX 77845
979.690-1504
979-690-1504
PLANS@OAKCHB.COM
plans@oakchb.com
Maximum SHGC: 0.40 Your SHGC: 0.30
Ceiling 1: Flat Ceiling or Scissor Truss:
998 0.0
30.0
31
Wall 1: Wood Frame, 16" o.c.:
960 13.0
0.0
62
3050 X 3: Metal Frame:Double Pane with Low-E:
45
0.540
24
SHGC: 0.30
1008: Metal Frame:Double Pane with Low-E:
2
0.540
1
SHGC: 0.30
2030: Metal Frame:Double Pane with Low-E:
6
0.540
3
SHGC: 0.30
4050 X 3: Metal Frame:Double Pane with Low-E:
60
0.540
32
SHGC: 0.30
2050: Metal Frame:Double Pane with Low-E:
10
0.540
5
SHGC: 0.30
3036: Metal Frame:Double Pane with Low-E:
20
0.540
11
SHGC: 0.30
3068 FRONT DOOR: Solid:
20
0.140
3
2868 BACK DOOR: Solid:
18
0.140
3
2868 TO GARAGE: Solid:
18
0.140
3
Wall 2: Wood Frame, 16" o.c.:
1040 13.0
0.0
85
CONC. SLAB: Slab-On-Grade:Unheated: , Insulation Depth: 0.0'
120
0.0
125
Heat Pump 1: Air Source: 7.7 HSPF, 13 SEER
Air Conditioner 1: Electric Central Air. 13 SEER
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building'has been designed to meet the 2003 IECC requirements in
REScheck Version 3.7.3 and to comply with the mandatory requirerents listed in the REScheck Inspection Checklist.
1 1-1 0210,916,7_
HORSEHAVEN LOT 8, BLK 1, PH2
Page 1 of 6
Builder/Designer - Company Name
Project Notes:
LOT 8, BLOCK 1, PHASE 2 HORSEHAVEN ESTATES
2715 HORSEHAVEN LANE
SEABISCUIT
Date
HORSEHAVEN LOT 8, BLK 1, PH2 Page 2 of 6
REScheck Software Version 3.7.3
Inspection Checklist
Date: 02/06/07
Ceilings:
❑ Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 continuous insulation
Comments:
Above -Grade Walls:
Q Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation
Comments:
❑ Wall 2: Wood Frame, 16" o.c., R-13.0 cavity insulation
Comments:
Windows:
❑ 3050 X 3: Metal Frame:Double Pane with Low-E, U-factor. 0.540
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break?
Yes No
Comments:
❑ 1008: Metal Frame:Double Pane with Low-E, U-factor. 0.540
For windows without labeled U factors, describe features:
#Panes Frame Type Thermal Break?
Yes No
Comments:
❑ 2030: Metal Frame:Double Pare with Low-E, U-factor. 0.540
For windows without labeled U factors, describe features:
#Panes Frame Type Thermal Break?
Yes No
Comments:
❑ 4050 X 3: Metal Frame:Double Pane with Low-E, U-factor. 0.540
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break?
Yes No
Comments:
❑ 2050: Metal Frame:Double Pane with Low-E, U-factor. 0.540
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break?
Yes No
Comments:
❑ 3036: Metal Frame:Double Pane with Low-E, U-factor. 0.540
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break?
Yes No
Comments:
Doors:
❑ 3068 FRONT DOOR: Solid, U-factor: 0.140
Comments:
❑ 2868 BACK DOOR: Solid, U-factor: 0.140
Comments:
Q 2868 TO GARAGE: Solid, U-factor. 0.140
Comments:
Floors:
HORSEHAVEN LOT 8, BUC 1, PH2
Page 3 of 6
❑ CONC. SLAB: Slab-On-Grade:Unheated, R-0 (uninsulated)
Comments:
Heating and Cooling Equipment:
❑ Heat Pump 1: Air Source: 7.7 HSPF, 13 SEER or higher
Make and Model Number:
❑ Air Conditioner 1: Electric Central Air. 13 SEER or higher
Make and Model Number:
Solar Heat Gain Coefficient:
❑ The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values must be
determined in accordance with the NFRC test procedure or taken from the default table.
Air Leakage:
❑ Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed.
❑ Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from
combustible materials. If non -IC rated, the fixture must be installed with a 3" clearance from insulation.
Skylights:
❑ Minimum insulation requirement for skylight shafts equal to or greater than 12 inches is R-13.
Materials identification:
❑ Materials and equipment must be installed in accordance with the manufacturers installation instructions.
❑ Materials and equipment must be Identified so that compliance can be determined.
❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided.
❑ Insulation R-values and glazing U-factors must be clearly marked on the building plans or specifications.
Duct Insulation:
❑ Supply ducts in unconditioned attics or outside the building must be insulated to R-8.
❑ Return ducts in unconditioned attics or outside the building must be insulated to R-4.
❑ Supply ducts in unconditioned spaces must be insulated to R-6.
❑ Return ducts in unconditioned spaces (except basements) must be insulated to R-2.
❑ Where exterior walls are used as plenums, the wall must be insulated to R-8.
❑ Insulation is not required on return ducts in basements.
Duct Construction:
❑ Duct connections to flanges of air distribution system equipment must be sealed and mechanically fastened.
❑ All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives),
mastic -plus -embedded -fabric, or tapes. Tapes and mastics must be rated UL 181A or UL 181B.
Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 In. w.g. (500
Pa).
❑ The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
❑ Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the
heating and/or cooling input to each zone or floor shall be provided.
Service Water Heating:
❑ Water heaters with vertical pipe risers must have a heat trap on both the Inlet and outlet unless the water heater has an integral
heat trap or is part of a circulating system.
❑ Insulate circulating hot water pipes to the levels in Table 1.
Circulating Hot Water Systems:
❑ Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
❑ All heated swimming pools must have an onloff heater switch and require a cover unless over 20% of the heating energy is from
non-depletable sources. Pool pumps require a time clock.
HORSEHAVEN LOT 8, BLK 1, PH2 Page 4 of 6
Heating and Cooling Piping Insulation:
❑ HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F must be insulated to the levels in Table
HORSEHAVEN LOT 8, BLK 1, PH2 Page 5 of 6
• . ,
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes
Insulation Thickness In Inches by Pipe Sizes
Non -Circulating Runouts Circulating Mains and Runouts
Heated Water
Temperature ("F)
Up to 1" Up to 1.25" 1.5" to 2.0"
Over 2"
170-180
0.5 1.0 1.5
2.0
140-169
0.5 0.5 1.0
1.5
100-139
0.5 0.5 0.5
1.0
Table 2. Minimum Insulation Thickness for HVAC Pipes
Piping System Types
Fluid Temp.
Range("F)
Heating Systems
Low Pressure/Temperature
201-250
Low Temperature
106-200
Steam Condensate (for feed water)
Any
Cooling Systems
Chilled Water, Refrigerant and
40-55
Brine
Below 40
NOTES TO FIELD: (Building Department Use Only)
HORSEHAVEN LOT 8, BLK 1, PH2
Insulation Thickness in Inches by Pipe Sizes
2" Runouts
1" and Less
1.25" to 2.0"
2.5" to 4"
1.0
1.5
1.5
2.0
0.5
1.0
1.0
1.5
1.0
1.0
1.5
2.0
0.5
0.5
0.75
1.0
1.0
1.0
1.5
1.5
Page 6 of 6