HomeMy WebLinkAboutRES2007-00318, 07-3190740si
PREPARED 6/21/07, 11:59:40 INSPECTION TICKET PAGE 10
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 6/27/07
------------------------------------------------------------------------------------------------
ADDRESS . : 2493 NEWARK CIR SUBDIV: CASTLEGATE SEC 5'PH 1
CONTRACTOR BLACKHAWK CUSTOM HOMES INC PHONE (979) 574-5459
OWNER GREENS PRAIRIE INVESTORS LTD PHONE
PARCEL 184200-1501-0030
APPL NUMBER: 07-00000318 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 3/02/07 OC BLDG, FOUNDATION -SLAB TIME: 17:00
3/02/07 AP March 2, 2007 10:09:30 AM glsouth.
B115 01 4/11/07 JGM BLDG, FRAMING TIME: 17:00
4/il/07 AE April 11, 2007 11:10:49 AM kwolfe.
04/11/2007 05:32 PM JGM PDA
need double joist at attic access and joist hangers,
fireblock between top plate and roof deck over fire place
B130 61 4/13/07 JGM BLDG, INSULATION TIME: 17:00
4/16/07 AP April 13, 2007 3:56:37 PM glsouth.
B125 01 6/27/ 7 BI BLDG, FINAL TIME: 17:00
�T June 27, 2007 9:49:10 AM kwolfe.
call lee @-574-5606--to get --in. —..-;-it i-s-locked-:
-----------------------L4r---------- COMMENTS AND NOTES --------------------------------------
t di
Dq t (qAV I
Date: 6/27/2007
Inspection Comments for Finals
Permit Year: 7 Permit Number: 318
Address: 2493 NEWARK CIR
Type
Inspection Type Code Description
status
Inspection Result Comments
B115
BLDG, FRAMING
IC
04/11/2007 05:32 PM JGM PDA
B115
BLDG, FRAMING
IC
need double joist at attic access and joist hangers,
B115
BLDG, FRAMING
IC
fireblock between top plate and roof deck over fire place
M100
MECH, ROUGH IN
IC
03/30/2007 11:43 AM RH PDA
M100
MECH, ROUGH IN
IC
Furnace flue needs min.1" of clearance from foof deck.
M100
MECH, ROUGH IN
IC
Main drain line has backfall near unit. Tape or mastic
M100
MECH, ROUGH IN
IC
seal inner liner of flex duct at connections, then strap
M100
MECH, ROUGH IN
IC
tight. Install flex duct lines with less sag and kinks.
M100
MECH, ROUGH IN
IC
Bathroom exhaust flex must be UL listed and approved for
M100
MECH, ROUGH IN
IC
use in an uncondition space.
Page 1
(6/27/2007) Gina Southerland Re: Callirig for CO @ 2493 Newark C'ir.u. Page _1)
From: Paul Schoenfeld
To: Amber Carter; Benjamin McCarty; Chris Haver; Gina Southerland; Joe G...
Date: 6/27/2007 3:09 PM
Subject: Re: Calling for CO @ 2493 Newark Cir
ALL OK.
PAUL
>>> Kim Wolfe 6/27/2007 12:10 PM >>>
any issues?
BP # 07-318
Thanks
Kimberly Wolfe, CPS/CAP
City of College Station
Planning & Development Services
(979) 764-3570
www.cstx.gov
WFO877954 / 00:1• City of College Station PAGE 1
REQ. DATE: 03/01/07 03/01/07 11:,40:03
LOCATION: 2493 NEWARK CIR - LOC ID: 200926
REQUESTOR: BLACKHAWK CUSTOM HOMES ORIGIN: CUSTOMER -WALK IN
REQ USER: GLSOUTH AUTH USER:GLSOUTH WRK TYPE:
TEMP POLE PASSED
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 03/01/07 SCHED COMPLETION: 03/01/07
********************************************************************************
JOB ORDER RESULT COMP ENTS
V
WF0872822 / 001 City of College Station PAGE 1
!ti
REQ. DATE:
02/08/07
02/08/07
14:11:45
LOCATION:
2493 NEWARK CIR
LOC ID:
200926
REQUESTOR:
BLACKHAWK CUSTOM HOMES INC ORIGIN:
CUSTOMER -WALK IN
'�REQ. USER:
NCOCHRAN AUTH. USER: NCOCHRAN
..WORK TYPE:
ROUT
4" SWR
TAP 3/4" WTR TAP
TASK:
SET UP NEW UTILITY ACCT SET
READY
SCHED START: 02/08/07 SCHED COMPLETION:
02/08/07
********************************************************************************
JOB ORDER
RESULT COMMENTS
_ N 03d13'03"
N 0201'07" _ —
_
I
r+__----------------YI
1
Ir 1
o
I I I I
I I
I � 1
12'-�" � I
I I r
I I I I I
I I I
1 I I
I I y I 1
I I
1 I I
1 I
w I
W I LOT 3, BLOCK 1 I r
I SECTION 5, PHASE 1 i
CASTLEGATE SUBDMSION I
1 I COLLEGE STATION, TEXAS I 31
I BRAZOS COUNTY I g�
I I �lca
I I
I I I 1
I I
1 I i
I I I 1
0'-4° i I I
I
I I
I I I
I
a' I
� I I
� I
I i I
CONCRETE ( 1
I DRMAY I
I I I
I I i
L— — — — — — — — — -- �L — — — — — — — — — —J `
I
I
C N
N
---.�-- C---..---..--- --- -.-�
N 01601" E
66.80'
\may
NEWARK C{ROLE 3wo.-N-iiw-
50 ROW
BUILDING PERMIT
CITY OF COLLEGE STATION
8
1101 TEXAS AVE
COLLEGE
STATION, TX 77840
PHONE: (979)764-3570
----------------------------------------------------------------------------
FAX: (979)764-3496'
Application Number .
. . . . 07-00000318
Date 2/08/07
Property Address . .
. . . . 2493 NEWARK CIR
Property ID:
184200-1501-0030
R #:
R300535
Application type description
RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . .
. . . . CASTLEGATE SEC 5 PH 1
Property Use . . . .
. . . . RESIDENTIAL
Property Zoning . . .
. . . . PLANNED DEVL HOUSING
Application valuation
. . . . 184000
Owner
Contractor
------------------------
GREENS PRAIRIE INVESTORS
------------------------
LTD BLACKHAWK CUSTOM
HOMES INC
4490 CASTLEGATE DR
3211 INNSBRUCK CIR
COLLEGE STATION
TX 778453388 COLLEGE STATION
TX 77845
(979) 574-5459
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
2220.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
2.00
NUMBER OF BEDROOMS
4.00
SEWER TYPE
PUBLIC
TAZ
441.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
NC
Permit Fee . . . .
712.00 Plan Check Fee
.00
Issue Date . . . .
2/08/07 Valuation . .
. . 184000
Expiration Date . .
8/07/07
Qty Unit Charge
Per
Extension
BASE FEE
460.00
84.00 3.0000
THOU BLDG, VAL 100001-500000
252.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS
THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL
BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS
OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
BUILDING DEPT REPRESENT
APPLICANT:
IVE:-------- ------ --- --'--------------
VE:
BUILDING PERMIT
s CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number 07-00000318
Page 2
Date 2/08/07
Special Notes and Comments
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH M ASURED AT THE
------------------------------------- ----- ----I -------------
BUILDING DEPT REPRESENTATIVE
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 07-00000318
Page 3
Date 2/08/07
Special Notes and Comments
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS -TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MAT RIAL FROM SLAB AREA
------------------------------------------ ----- -------------
BUILDING DEPT REPRESENTAT E:
APPLICANT: L�'—
�%>
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page
4
Application Number . . . . . 07-00000318 Date
2/08/07
----------------------------------------------------------------------------
Special Notes and Comments
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND
CLOTHES DRYERS.
Narrow Wall Bracing Fully Sheathed with APA Right Side
Garage Framing and some plan changes per Drawings.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------------------------------
-----------------
Permit Fee Total 712.00 712.00 .00
.00
Plan Check Total .00 .00 .00
.00
Other Fee Total 750.00 750.00 .00
.00
Grand Total 1462.00 1462.00 .00
.00
-------------------------------------------- ---- -- ------------
BUILDING DEPT REPRESENTATIVE
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
07-00000319
Date 2/08/07
Property Address . . . . . .
2493 NEWARK CIR
Property ID:
184200-1501-0030
Application type description
TEMP POLE
Subdivision Name . . . . . .
CASTLEGATE SEC 5 PH 1
Property Use . . . . . . . .
RESIDENTIAL
Property Zoning . . . . . . .
PLANNED DEVL HOUSING
Application valuation . . . .
0
Owner
Contractor
------------------------
GREENS PRAIRIE INVESTORS LTD
------------------------
BLACKHAWK CUSTOM
HOMES INC
4490 CASTLEGATE DR
3211 INNSBRUCK CIR
COLLEGE STATION TX 778453388
COLLEGE STATION
TX 77845
(979) 574-5459
----------------------------------------------------------------------------
Permit . . . . . . TEMP POLE
PERMIT
Additional desc . . NC
Permit Fee . . . . 20.00
Issue Date . . . . 2/08/07
Valuation . .
. . 0
----------------------------------------------------------------------------
Other Fees . . . . . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary Charged
Paid Credited
--------------------
Due
----------
---------------------------
Permit Fee Total 20.00
20.00 .00
.00
Other Fee Total 45.00
45.00 .00
.00
Grand Total 65.00
65.00 .00
.00
--------------------------------- ------ - - -----------
BUILDING DEPT REPRESENT IVE:
APPLICANT:
w r%ac�e onry
APPLICATION FOR BUILDING PERMIT DATE: �/TRCC REG
CITY OF COLLEGE STATION rl
1101 TEXAS AVENUE APPLICATION # l� _
COLLEGE STATION, TX 77840 TEMP POLE #
CITY Or COLLLGE STNT10N (979) 764-3570 (979) 764-3496 FAX
Pliaui»S Gt L)nx/uPmmt $acirrx
WWW.CSTX.GOV
ADDRESS/LOCATION: 9W.3
/(ICLI,Y,t(- (jl•( I�i v
LOT 3 v BLOCK — SUBDIVISION / SEC/P /
BUSINESS/OWNER NAME: IJIGGKhCi1uk (� orry once ,�/�/ . PHONE:
CONTRACTOR/HOMEOWNER: 16"LJO 9bM t'10/rt'��.'l�G• PHONE: 97,q
CONTRACTOR ADDRESS: 1�nn5hro&C'nd,!, 7�� C.5. K
���
ELECTRICIAN: I�fGCGCn t, PLUMBER: lam. M-eilo,
HVAC: C e-0rCtee,L GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION " SLAB ONLY
DUPLEX (Landscape Plans REMODEL/RENOVATION* SWIMMING POOL
Required)
DESCRIPTION OF WORK: ('61
STRUCTURE USE: 1c, Ar, 5 aeld,CGI
HOMEOWNER ASSOC IATION/ARCH ITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: --f ` 6
TEXAS ACCESSIBILITY STANDARD (TA S) P%JECT REGISTRATION# EABPRJ
VALUATION: $ 060 ✓ TOTAL AREA: o��I�o HEATED AREA:�Z
(Cost of Labor And Materials)
PUBLIC SEWER
SEPTIC/TREATMENT SYSTEM
Fkj SEWER TAP:
SIZE
WATER TAP:
SIZE
OTHER TAP:
SIZE
TEMP POLE
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
GARAGE TYPE: SINGLE F-1 DOUBLE
ATTACHED 9 DETACHED
SIGNATURE OF APPLICANT: t
*If proposed work involves new commercial const
commercial property, building elevations are requ
Official Use Only C ents:
rND
Zoning Official
TRIPLE
CARPORT
fjf t'GL Istone,
ebb on 6rG,k,
1
✓�Ip Plans Examiner
d Gmb� ye w/#
f11y s C'
G d IAI' 4/.OS R Pic
or facade improvements/renovations to an existing
Energy Code Compliance Information
% Glazing of exterior wallsy
�J
Insulati•n R value of exterior walls
Insulation R value of ceiling I (flat areas) v
Insulation R value of ceiling 2 (vaulted areas/no attic) �D
Glazing SHGC /
Glazing U-Factor `
R value of ductwork /
A/C SEER Rating 3 V
.... i^'"
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# n _ 31 o DATE:
BUILDING ADDRESS: �y
I. Foundation Requirements
N K
A.
Concrete minimum fc of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier 6 mil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior unless over 60' Ion
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F.
Wood foundation details indicated
OK
II. Framing: Floor, Wall, Ceiling and Roof Requirements
N
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
OK
1. One -hour rated extending to roof deck
OK
E.
Header sizes indicated on plans
F.
Emergency bedroom egress
1. Exit direct to outside
2. O enable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
O enable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
N.
O.
P.
Span exceeding code tables must be engineered
Rafter size and spacing and purlin bracing indicated.
Roof covering used.
Indicate Wall Bracing Used for Lateral Bracing
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
II. Framing: Floor, Wall, Ceiling and Roof Requirements continued
N
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
S. 18" Overhang allowed on zero lot line construction, perforated soffit allowed.
T. Protected openings on walls < three feet from property line
OK
$
III. Stairway Requirements
t4AOOK
A. Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" diff. max.
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches above handrail
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located four or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four (4) inch sphere
IV. Fireplace Requirements (to be indicated onplans)
NACOYj
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must extend at least three (3) feet higher than the highest point where it
projects through the roof of a building & at least two (2) feet higher than any portion of the
building within ten (10) feet horizontal
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
V. Electrical Service Requirements
N K
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
VI. Plumbing Requirements
N
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N O
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
Vill. Energy Requirements
N K
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
NA/
Maximum drive width for residence is 25combined for circular 12' minimum
Minimum 20 feet from driveway to side(intersecting) street
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
NA/
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
N
Does not block any water course or divert any flow
Elevation certificate needed
OK
PLANS EXAMINER
"APPROVED PLANS PER IRC SECTION R106.3.1."
a2 -S -CO
DATE