Loading...
HomeMy WebLinkAboutCNEW2007-00307I=.* ,)047 Date Permit # Project Name COMMERCIAL CO Planning "— (Lindsay Boyer, Jennifer Prochazka, Jennifer Reeves, Crissy Hartl, Jason Schubert, Grant Wencel, Molly Hitchcock) Bridgette George Development Engineers (Alan Gibbs, Josh Norton, Carol Cotter) City Engineer (Bob Mosley, Jerry Jones, John Logan, Robert Bumpurs, William Ethridge) Environmental Services OIL (Eaphrame Thomas, James Boykin, Pete Garcia) Fire Department ,( APO (Eric Hurt, Eric Dotson, Jerry Duffey, Steve Smith) Drainage (Donnie Willis) Public Works - Sanitation (Wally Urrutia) Electrical Services (Tony Michalsky) Miscellaneous Notes 1363 Date: #� D # of pages including cover: If you did wort receive a complete fax, plwse call our of xe immediately for a new transmittal. TO: 1`uw M moff MIN w. • a FROM: FAx: q 71- 836-1343 COMPANY: Cily of College Station REMARKS: ❑ Urgent For your review ❑ Reply ASAP ❑ FYI W03 QddQNd1S 3QOW Z0 (S)3Jdd ZZ :00 :00 NOIivand #Z08E9--E9EZ0E86L6T6 3WdN/•ON Xdd 6E:60 bZ/L0 3WI1`31dQ 008965I'5-1000 # • d3S -131 Xd3 3WdN 66:60 L00Z/bZ/L0 3WI1 1dOd3d NOIiV0I3Id3A NOISSIWSNddl City of College Station 1101 TEXAS AVENUE COLLEGE STATION TX 77840 C E R T I F I C A T E O F O C C U P A N C Y P E R M A N E N T Issue Date . . . . . . 7/23/07 Parcel Number . . . . . 538850-0001-0010 Property Address . . . 1651 ROCK PRAIRIE RD 200 COLLEGE STATION TX 77845 Subdivision Name . . . Legal Description . . . REMINGTON, BLOCK 1, LOT 1, ACR ES 4.00 Property Zoning ADMIN. PROFESSIONAL Owner . . . . . . . . . R & S LEASING Contractor . . . . . . Application number Description of Work Construction type . . . Occupancy type . . . . Flood Zone . . . . . . Approved . . . . . . . CHAPPELL HILL CONSTRUCTION 979 836-7823 07-00000307 000 000 COMMERCIAL, OFFICES/BANKS/PROFESSION NON-COMBUSTIBLE BUSINESS Building Of flicial VOID UNLESS SIGNED BY BUILDING OFFICIAL lcanntng crtvevefgmen�=�emces;;;. 1101 Texas Avenue South, PO Box 9960 College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 FACSIMILE COVER SHEET Date: 1214101 # of pages including cover: If you did mot receive a complete fax, please call our office immediately for a new transmittal. TO: l� COMPANY: FROM: &v is &X-1f. FAX: q 1q - 836 -13 0 COMPANY: City of College Station REMARKS: ❑ Urgent [] For your review ❑ Reply ASAP ❑ FYI (7/20/2007) Kim Wolfe ----Re-:- Calling for CO @ 1651 Rock Prairie Rd 200 (finish out of 2nd floor) _ _W Page 1 From: Pete Garcia To: Alan Gibbs; Amber Carter; Benjamin McCarty; Bob Mosley; Brian Wells;... Date: 7/20/2007 3:35 PM Subject: Re: Calling for CO @ 1651 Rock Prairie Rd 200 (finish out of 2nd floor) Attachments: Pete Garcia.vcf CC: Peter G Garcia No Issues. This e-mail and/or attachment is for the sole use of the intended recipient(s) and may contain confidential and /or legally privileged information. Any unauthorized review, use, disclosure or distribution is prohibited. If you are not the intended recipient, please contact the sender by reply e-mail and destroy all electronic and paper copies of the original message and any attachments. Thank You. >>> Kim Wolfe 07/20/07 8:02 AM >>> Are there any issues? Contact: Chappell Hill Construction @ 979-836-7823 x BP # 07-307 Thanks Kimberly Wolfe, CPS/CAP City of College Station Planning & Development Services (979) 764-3570 www.cstx.Qov (7/20/2007) Kim Wolfe Re: Calling for CO @ 1651 Rock Prairie Rd 200 (finish out of 2nd floor)Page 1 From: Tony Michalsky To: Kim Wolfe Date: 7/20/2007 9:20 AM Subject: Re: Calling for CO @ 1651 Rock Prairie Rd 200 (finish out of 2nd floor) ok with us >>> Kim Wolfe 7/20/2007 8:02 AM >>> Are there any issues? Contact: Chappell Hill Construction @ 979-836-7823 BP # 07-307 Thanks Kimberly Wolfe, CPS/CAP City of College Station Planning & Development Services (979) 764-3570 www.csbc.goy _. _ _ _ _ _._.A___._. ._. _w _ w.. 02=007) Kim Wolfe R _. Calling for CO @ 1651 Rock Praise Rd 200 (finish out of 2nd floor) _ Page 1,? From: Donnie Willis To: Wolfe, Kim Date: 7/20/2007 8:06 AM Subject: Re: Calling for CO @ 1651 Rock Prairie Rd 200 (finish out of 2nd floor) OK with Drainage. Donnie Willis, CFM Environmental Engineering Technician Certified Floodplain Manager Public Works Department 979-764-6375 office 979-229-7632 cell dwillis@cstx.gov >>> On 7/20/2007 at 8:02 am, in message<46A06C2A.38F0.0012.0@cstx.gov>, Kim Wolfe wrote: Are there any issues? Contact: Chappell Hill Construction @ 979-836-7823 BP # 07-307 Thanks Kimberly Wolfe, CPS/CAP City of College Station Planning & Development Services (979)764-3570 www.cstx.gov Date: 7/20/2007 Inspection Comments for Finals Permit Year: 7 Permit Number: 307 Address: 1651 ROCK PRAIRIE RD Insp. Inspection Type code p. status Inspection Result Comments Description B120 BLDG, FRAMING -PARTIAL IC February 23, 2007 8:14:30 AM kwolfe. B120 BLDG, FRAMING -PARTIAL IC except plumbing walls M105 MECH, CEILING COVER UP IC July 3, 2007 10:36:47 AM acarter. P100 PLBG, ROUGH IN IC March 2, 2007 2:17:54 PM ncochran. P100 PLBG, ROUGH IN IC called in to cancell Page 1 PREPARED 7/20/07, 7:14:31 INSPECTION TICKET PAGE 3 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 7/20/07 ------------------------------------------------------------------------------------------------ ADDRESS . : 1651 ROCK PRAIRIE RD 200 SUBDIV: TENANT, NBR: FINISH OUT OF MED OFFICES CONTRACTOR CHAPPELL HILL CONSTRUCTION PHONE (979) 836-7823 OWNER R & S LEASING PHONE PARCEL'. 538850-0001-0010 APPL NUMBER: 07-00000307 COMMERCIAL, OFFICES/BANKS/PROFESSION ----------------------------------------------------- 7------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B130 01 2/20/07 OC BLDG, INSULATION TIME: 17:00 2/20/07 AP February 20, 2007 9:39:10 AM kwolfe. exterior walls B120 01 2/23/07 JGM BLDG, FRAMING -PARTIAL TIME: 17:00 2/23/07 AP February 23, 2007 8:13:30 AM kwolfe. February 23, 2007 8:14:30 AM kwolfe. except plumbing walls B135 01 7/02/07 OC BLDG, CEILING COVER UP TIME: 17:00 7/02/07 AP June 29, 2007 10:31:04 AM acarter. ... ,:125 01 7 /20/07 BLDG, FINAL TIME: 17:00 • July 18, 2007 3:08:26 PM glsouth. 2ND FLOOR —ONLY--- -----=------------------- ------ COMMENTS AND NOTES-------------------------------------- t J' -.4 BUILDING PERMIT CITY OF COLLEGE STATION f 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 07-00000307 Date 2/15/07 Property Address . . . . . . 1651 ROCK PRAIRIE RD Property ID: 538850-0001-0010 R #- Tenant nbr, name . . . . . . FINISH OUT OF MED OFFICES Application type description COMMERCIAL, OFFICES/BANKS/PROFESSION Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . ADMIN. PROFESSIONAL Application valuation 634423 Owner Contractor ------------------------ ------------------------ R & S LEASING CHAPPELL HILL CONSTRUCTION PO BOX 602 1705 S. HORTON (77833) BRENHAM TX 778340602 PO BOX 602 BRENHAM TX 77834 (979) 836-7823 --- Structure Information 000 000 MED OFFICE FINISHOUT Construction Type . . . . . NON-COMBUSTIBLE Occupancy Type . . . . . . BUSINESS Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB HEATED AREA 1.00 INTERIOR WALL TYPE SHEETROCK SEWER TYPE PUBLIC TAZ 376.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . NC Permit Fee . . . . 1930.00 Plan Check Fee .00 Issue Date . . . . 2/15/07 Valuation . . . . 634423 Expiration Date . . 8/14/07 Qty Unit Charge Per Extension BASE FEE 1660.00 135.00 2.0000 THOU BLDG, VAL 500001 & UP 270.00 ---------------------------------------------------------------------------- Special Notes and Comments PROVIDE ADDRESS ON COMMERCIAL BUILDINGS -FRONT 5" NUMBERS REAR - 2" HIGH NUMBERS WITH NAME OF BUSINESS PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE Underground electrical conduit installation shall be installed per city specs and is the responsibility of the ----------- ---- --- --- -- -- - - ----------- ------- BUILDING DEP R RESENT,�7I APPLICANT: i� BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 07-00000307 Page 2 Date 2/15/07 Special Notes and Comments owner and/or contractor. Contact the electrical division at (979) 764-6314 for more information. ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET SUBMIT FIRE ALARM PLANS WITH PRODUCT DATA SHEETS - DESIGN AND INSTALL AS PER NFPA 72 NO WORK SHALL START UNTIL PLANS HAVE BEEN REVIEWED AND RETURNED PROVIDE FIRE EXTINGUISHERS) - VERIFY LOCATION AND PLACEMENT WITH THE FIRE MARSHALL'S OFFICE (MIN. 2A10BC) SUBMIT FIRE SPRINKLER PLANS AND CALCULATIONS FOR REVIEW NO WORK ON SPRINKLER SYSTEM SHALL BEGIN UNTIL PLANS HAVE BEEN REVIEW AND RETURNED. SPRINKLER SYSTEM CONTROLS AND WATER FLOW SWITCHES ARE REQUIRED TO BE MONITORED BY AN -APPROVED MONITORING COMPANY. A COPY OF THE MONITORING CONTRACT SHALL BE SENT TO THE COLLEGE STATION FIRE DEPARTMENT, FIRE PREVENTION DIVISION. Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit PROVIDE A KNOX BOX FOR FIRE DEPARTMENT ACCESS. All outdoor lighting must be in compliance with Section 7.10, Outdoor lighting Standards of the City's Unified Development Ordinance All roof and ground -mounted mechanical equipment shall be sreened from view or isolated so as not to be visible from any public right-of-way or residential district within 150 feet of the subject lot, measured from a point five feet above grade. Such screening shall be coordinated with the building architecture and scale to maintain a unified appearance. Acceptable methods of screening rooftop equipment may include, but are not limited to encasement, parapet walls, or partition screens. COLLEGE STATION ELECTRICAL DIVISION REQUESTS THAT THE METER CAN/ELECTRICAL SERVICE DISCONNECT BE LOCATED ON THE STRUCTURE AS CLOSE AS POSSIBLE TO THE SECONDARY FEEDER CONDUIT FROM THE TRANSFORMER. (see site plan for location of conduit or contact electrical division) CONSTRUCTION ACTIVITY BETWEEN THE HOURS OF 10:00 PM AND 7:00 AM MUST COMPLY WITH THE NOISE ORDINANCE (MAX. 55 DBA) PROVIDE PANIC HARDWARE ON EXIT DOORS "EP BUILDING DEPT SENTATITT, �� 99 -- Y� - - APPLICANT: �- BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 07-00000307 Date 2/15/07 ---------------------------------------------------------------------------- Special Notes and Comments If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI CONSTRUCTION CONTRACTS OVER $50,000 REQUIRE SUBMISSION TO THE STATE FOR ACCESSIBILITY REVIEW - CONTACT TDLR @ (512) 463-3211 FOR MORE INFORMATION TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK PROVIDE SMOKE DETECTOR IN RETURN AIR OF UNITS GREATER THAN 2000 CFM THAT WILL SHUT DOWN UNIT IF SMOKE IS PRESENT. CONNECT TO FIRE ALARM SYSTEM. ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total 1930.00 1930.00 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 1930.00 1930.00 .00 .00 ---------------------- - ------- -- ----------- _----------- E BUILDING DEPT TI ----- APPLICANT: W� APPLICATION FOR BUILDING PERMIT 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX CITY OF COLLEGE STATION WWW.CSTX.GOV Plrtnriing.d'Developinerit$erLiiFi. ADDRESS/LOCATION: �CP ✓� / C ���/ e (/�' For Office Use Only DATE: TRCC REG APPLICATION # TEMP POLE # LOT BLOCK SUBDIVISION SEC/PH BUSINESS/OWNER NAME: PHONE: C�%- CONTRACTOR/HOMEOWNER: ',af' /l �'ii C�,F� PHONE: / 7 `7 �3 3 CONTRACTOR ADDRESS: ���-s ��/ter P�� ��/i��J �/J� P N �p>�• — �L ELECTRICIAN: O ��Pr' /� ��� PLUMBER: HVAC: _(/�4 99 J� ���%2� cj�/' - GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ONLY DUPLEX (Landscape Plans) REMODEL/RENOVATION* SWIMMING POOL TENT/CANOPY DESCRIPTION OF WORK: // %� i�✓� ^o{ i PROPOSED USE: HOMEOWNER ASSOC IATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPR/ �'_-<P VALUATION: $ 6 `� �� 3. `�� TOTAL AREA: HEATED AREA: 3�2 (Cost of Lab r and Materials) PUBLIC SEWER NUMBER OF BEDROOMS: SEPTIC/TREATMENT SYSTEM ❑ SEWER TAP: WATER TAP: ❑ OTHER TAP: TEMP POLE GARAGE TYPE NZE SIZE SIZE SINGLE a ATTACHED 171 NUMBER OF BATHROOMS: INTERIOR WALL TYPE: EXTERIOR WALL TYPE: FOUNDATION TYPE: ROOF TYPE: DOUBLE F] ETACHED TRIPLE PORT 'LLUIP 78clz 3 78� 3 97 9-goo — /36; 'fa ), SIGNATURE OF APPLICANT: *If proposed work involves new commeE54d construction or facade i6 provements/renovations to an existing commercial property, building elevations are required. Official Use Only Zoning Official Fire Marshall Comments: ES r NO Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER Rating ABProjRegForm Page 1 of 2 Texas Department of Licensing and Regulation Architectural Barriers Project Registration Confirmation Page Monday, February 05, 2007 EABPRJA7809215 PERSON FILING FORM Name: Eddie Hare Email: hares3211`c,msn,com Phone: 979-775-6850 RAS Number: 00000008 Project Name: New Administration Offices for College Station Medical Center Project College Station Professional Building 2 Address: 1603 Rock Prairie Road College Station, TX 77845 County: Brazos TENANT Name: College Station Medical Center Phone: 979-764-5185 Tenant Address: 1602 Rock Prairie Road; College Station, Tx 77845 Contact Name: Frank Hartman Phone: 979-764-5185 Contact Address: BUILDING/FACILITY Name: College Station Professional Building 2 FACILITY Owner: R & S Leasing Phone: 979-836-7823 Owner Address: 1704 South Blubell. Brenham, Tx 77833 Contact Name: Walt Schoenvogle Phone. 979-836-7823 Contact Address: DESIGN FIRM Name: Williamson Group Architects Phone: 979-775-1778 Firm Address: 106 East 26th Street, Bryan, Tx 77803 Designer Name: C. Leon Williamson Email: wilgrp(`ctxcyber.com Type of License: Architect License Number: 7530 PROJECT DESCRIPTION Date Construction Documents Received By RAS: 02/05/2007 Start Date: 02/2007 Completion date: 06/2007 Estimated Cost: $683,300.00 Type of Work: New Construction Does this building(s) have more than one level? Yes Are there any elevators, escalators, or platform lifts in this building? Yes Type of Funds: This project is privately funded, on private land for private use. State Lease No. : Scope of Work: Tenant improvement of 15382 sgft, including rr, breakrooms, offices, and meeting rooms I will submit this AB Confirmation Page, Project Status Update Form and applicable fees to TDLR at P.O. Box 12157 Austin, Texas 78711 in accordance with the Texas Administrative Code Chapter 68. 00000008 Signature of RAS OR Name of CP RAS/CP# Enter Another Project 02/05/2007 Date Construction Documents Received by RAS Print this Page Top of PagelTDLR Home PageIAB Home PageJAB Project Registration Pagel Feedback file: //C:\Documents and Settings\Ray Andrejczak\Local Settings\Temporary Internet Files\OLK25C\ABPr... 2/5/2007 I ' City of College Station 1101 TEXAS AVENUE COLLEGE STATION TX 77840 / 0 C E R T I F I CAT B OF COMPLETION PERMANENT Issue Date . . . . . . 1/05/07 Parcel Number . . . . . 538850-0001-0010 Property Address . . . 1651 ROCK PRAIRIE RD COLLEGE STATION TX 77845 Subdivision Name Legal Description . . . REMINGTON, BLOCK 1, LOT 1, ACR ES 4.00 Property Zoning ADMIN. PROFESSIONAL Owner . . . . . . . . . R & S LEASING Conti -actor . . . . . . CHAPPELL HILL CONSTRUCTION CO. 979 836-7823 Application number . . 06-00000758 000 000 Description of Work . . COMMERCIAL, OFFICES/BANKS/PROFESSION COnsi-ructlon type LT/1,T /.n,�rnTTG.TTflT a. Occupancy type Flood Zone Approved . . . . . . VOID UNLES A Permit # Permit Date COMcheck Software Version 3.1 Release 1 -- -- Lighting Compliance Certificate 2003 IECC Report Date:02101/07 Data filename: D:tENERGY REPORTS%02-0603 MED OFF10Ecck Section 1: Project Information Project Title: CS THE IVIED ADMIN AREA TENANT FINISHOUT Construction Site: Owner/Agent: ROCKPRAIRIE RD CHAPPEL HILL CONSTRUCTION COLLEGE STATION, TX 77845 BRENHAM, TX Section 2: General Information Building Use Description by: Activity Type Project Type; New Construction Activity Tvoetsl Floor Area Medical and Clinical Care 11814 Corridor, Restroom, Support Area 3073 Section 3: Requirements Checklist Interior Lighting: 1. Total actual watts must be lest than or equal to total allowed watts. Allowed Watts Actual Watts Complies 16942 10448 YES ❑ 2, Exit signs 5 Watts or less per side. Oesig ner/Con tractor: PAUL SWOBODA SWOBODA ENGINEERING 7010 COYOTE RUN BRYAN. TX 77808 979.774.3400 paul@swoboda-eni ineering.com Exterior Lighting: ❑ 3. Efficacy greater than 45 lumens/W. Exceptions: Specialized lighting highlighting features of historic buildings; signage; safety or security lighting; low -voltage landscape Fighting. Controls, Switching, and tiring: ❑ 4. Independent controls for each space (switchfoccupancy sensor). Exceptions: Areas that must be continuously Illuminated. ❑ 5. Master s•.vitch at entry to hotellmotet guest room. ❑ 6. Individual dwelling units separately metered. ❑ 7. Each space provided with a manual control to provide'uniform light reduction by at least 50%. Exceptions: Only one Iuminaire in space: An occupant -sensing device controls the area: The area is a corridor, storeroom, restroom, public lobby or guest room: Areas that must be continuously illuminated; Areas that use less than 0.6 Wattslsq.R- C) 8. Automatic lighting shutoff control in buildings larger than 5,000 sq.ft. O 9,. Photocell/astronomical t.ime switch on exterior lights. Exceptions. Lighting intended for 24 hour use. 0 10. Tandem wired one -lamp and three -lamp ballasted luminaires (No single -tamp ballasts). Exceptions. Electronic high -frequency ballasts; Luminaires on emergency circuits or with no available pair. Section 4: Compliance Statement Coaipfiance Statement. The proposed lighting design represented In this document is consistent vnih the building plans, specifications and other calculations submitted with this permit application. The proposed lighting system has been designed to meet. the 2003 IECC, Chapter 8, requirements in COMcheck Version 3.1 Re a to comply with the mandatory requirements in the Requirements Checklist. t;�yleG� /�cRPrTx� oZ.—of—o�- Principal Lighting Designer -Name Signature Date r 011i z7of7 Permit .# Permit Date COMcheck Software Version 3.1 Release 1 ----- Lighting Application Worksheet 2003 IECC Report Date: Data rhr ame: D:IENERGY REPORTSW02-0603 MED OFFICE.cck Section 1: Allowed Lighting Power Calculation A B C D Area Category Floor Area Allowed Allowed Watts (R2) Watts 1 M (B x C) Medical and Clinical Care 11814 1.2 14177 Corridor Restroom Support Area 3073 0.9 2766 Total Allowed Watts = 16942 Section 2: Actual Lighting Power Calculation A B C 0 E Fixture ID : D©scription / Lamp I Wattage Per Lamp I Ballast Lamps/ # of Fixture (C X D) Fixture Fixtures, Watt. TS 1 T12 Fluorescent 1: A; 2.X4 2TUBE FLOUR / 48' T8 32W I Electronic 2 139 65 9035 T8 i T12 Fluorescent 3: Ct 2x2 2 TUBE I24' T8 17W I Electronic 2 9 33 '297 Linear Fluorescent 4: B:'2X4 4'TUBE FLOUR / 48" T8 32W 7. Electronic 4 9 124 1116 Total Actual Watts = 10448 Section 3: Compliance Calculation if the Total Allowe_ d Watts minus the Total Actual Watts is greater than or equal to zero. the building complies. Total Allowed Watts= Total Actual Watts Project Compliance LIgh1Ug.PASSM Design 38% better than code. Permit # Permit Date COMcheck Software Version 3.1 Release 1 1 11, X. Mechanical Compliance Certificate 2003 IECC Report Date: 02/01/07 Data filename: D:IENERGY REPORTS1A02-0603 MED OFFICE.cck Section 1: Project Information Project Title: CSTHEE MED ADMIN AREA TENANT FINISHOUT Construction Site: Owner/Agent: ROCKPRAIRIE RD CHAPPEL HILL CONSTRUCTION COLLEGE STATION, TX 77845 BRENHAM, TX Section 2: General Information Building Location (for weather data): Bryan (Brazos), Texas Climate Zone: 4b Heating Degree Days (base 65 degrees F): 1788 Coding Degree Days (base 65 degrees F). 2776 Project Type: New Construction Section 3: Mechanical Systems List Designer/Contractor: PAUL SWOBODA SWOBODA ENGINEERING 7010 COYOTE RUN BRYAN. TX 77808 979.774.3400 paul@swoboda-engineering:com Quantity System Type & Description 12 HVAC System 1: Water Loop Heat Pump. Cooling Capacity <65 kStu/h, Water -Cooled Condenser / Single Zone 5 Storage Water Heater 1: Service Water Heater Section 4: Requirements Checklist Requirements Specific To: HVAC System 1 : ❑ 1, Equipment minimum efficiency- Heat Pump: 4.2 COP, 12.0 EER ❑ 2. Heat pump thermostat required when supplemental electric resistance heat is installed Generic Requirements: Must be met by all systems to which the requirement is applicable: ❑ 1. Load calculations per 1997 ASHRAE Fundamentals ❑ 2. Plant equipment and system capacity no greater than needed to meet loads Exception: Standby equipment automatically off when primary system is operating Exception: Multiple units controlled to sequence operation as a function of load ❑ 3. Minimum one temperature control device per system 4- Minimum one humidity control device per installed humidificatlon/dehumidification system ❑ 5. Automatic Controls: Setback to 55 degrees F (heat) and 85 degrees F (cool); 7-day clock. 2-hour occupant override, 10-hour backup Exception: Continuously operating zones Exception: 2 kW demand or less, submit calculations ❑ 6. Automatic shut-off dampers on exhaust systems and supply systems with airflow >3,000 cfm ❑ 7. Outside -air source for ventilation; system capable of reducing OSA to required minimum ❑ 8. R-5 supply and return air duct Insulation in unconditioned spaces R-6 supply and return air duct insulation outside the building R-8 insulation between ducts and the building exterior when ducts are part of a building assembly Exception: Ducts located within equipment Excepbon: Ducts with interior and exterior temperature difference not exceeding 15 degrees F. t] 9. Ducts sealed -longitudinal seams on rigid ducts; transverse seams on all ducts: UL.181A or 1 B1 B tapes and mastics - Exception: Contlnuou sly welded and locking -type longitudinal joints and seams on ducts operating at static pressures less than 2 inches w.g. pressure classification * 10. Mechanical fasteners and sealants used to connect ducts and air distribution equipment 0 11. Operation and maintenance manual provided to building owner © 12. Balancing devices provided In accordance with IMC 603.15 fJ 13. rfe+•rry purchased service water heating equipment meals the efficiency requirements 14. Water heater temperature controls. 110 degrees F far dwelling units or 90 degrees F for other occupancies 15. Stair and elevator shaft vents are equipped with motorized dampers Section 5: Compliance Statement Compliance Statement- The proposed mechanical design represented in this document is consistent with the building plans, spesificatlons and other calculations submitted with this permit application. The proposed mechanical systems have been designed to meet the 2003 IECC requirements in COMcheck Version 3.1 Release 1 and to comply with the mandatory requirements in the Requirements Checklist. 6co"C- Ke.eP,rT/� vz—cl—o - Prinncipat Mechanical Designer -flame 8ignatvr Date COMcheck Software Version 3.1 Release 1 Mechanical Requirements Description 2003 IECC Report Date: Data filename: WENERGY REPOR.TS1A02-0603 MED OFFICE.cck The following list provides more detailed descriptions of the requirements in Section 4 of the Mechanical Compliance Certificate. Requirements Specific To: HVAC System 1 : The specified heating and/or cooling equipment is covered by the ASHRAE 90,1 Code and must meet the following minimum efficiency: Heat: Pump: 4.2 COP. 12.0 EER 2- Heat pumps having supplementary electric resistance heat must have controls that, except during defrost, prevent supplementary heat operation when the heat. pump can meet the heating load Generic Requirements: Must be met by all systems to which the requirement is applicable: 1. Design heating and cooling loads for the building must be determined using procedures equivalent to those in Chapters 27 and 28 of the ASHRAE Handbook of Fundamentals or an approved equivalent calculation procedure. 2. All equipment and systems must be sized to be -no greater than needed to meet calculated loads. A single piece of equipment' providing both heating and cooling must satisfy this provision for one function with the capacity for the other function as small as possible, within available equipment options- - Exception: The equipment and/or system capacity may be greater than calculated loads for standby purposes. Standby equipment must be automatically controlled to be off when the primary equipment and/or system is operating. - Exception: Multiple units of the same equipment type whose combined capacities exceed the calculated load are allowed if they are provided with controls to sequence operation of the units as the load Increases or decreases. 3. Each heating or cooling system serving a single zone must have its own temperature control device. 4. Each humidification system must have its own humidity control device. 5. The system or zone control must be a programmable thermostat or other automatic control meeting the following criteriam) capable of setting back temperature to 55 degrees F during heating and setting up to 85 degrees F during coolingb) capable of automatically setting back or shutting down systems during unoccupied hours using 7 different day schedulesc) have an accessible 2-hour occupant overrided) have a battery back-up capable of maintaining programmed settings forest least 10 hours without power. - Exception: A setback or shutoff control is not required on thermostats that control systems serving areas that operate continuously, - Exception: A setback or shutoff control is not required on systems with total energy demand of 2 kW (6,826 Bluth) or less. 6. Outdoor -air supply systems with design airflow rates >3,000 cfm of outdoor air and all exhaust systems must have dampers that are automatically closed while the equipment is not operating. 7- The system must supply outside ventilation air as required by Chapter 4 of the Intemational Mechanical Code. If the ventilation system is designed to supply outdoor -air quantities exceeding minimum required levels, the system must be capable of reducing outdoor -air flow to the minimum required levels. S. Air ducts must be Insulated to the following levels:a) Supply and return air ducts for conditioned air located in unconditioned spaces (spaces neither heated nor cooled) must be insulated with a"minimum of R-5. Unconditioned spaces include attics,. crawl spaces, unheated basements, and unheated garages.b) Supply and return air ducts and plenums must be insulated to a minimum of R-8 when located outside the building.c) When ducts are located within exterior components (e.g., floors or roofs),, minimum R-8 insulation is required only between the duct and the building exterior. - Exception: Duct insulation is not required on ducts located within equipment. - Exception: Duct insulation is not required when the design temperature difference between the interior and exterior of the dud or plenum does not exceed 15 degrees F. 9. All joints, longitudinal and transverse seams, and connections In ductwork must be securely seated using weldments; mechanical fasteners with seals, gaskets, or mastics: mesh and mastic sealing systems; or tapes. Tapes and mastics must be listed and labeled in accordance with UL 181A or UL 181B. - Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at static pressures less than 2. Inches w.g. pressure classification. 10. hiecbanical fasteners and seals, mastics, or gaskets must be used when connecting ducts to fans and other air distribution equipment, including multiple -zone terminal units. 11. Operation and maintenance documentation must be provided to the owner that includes at least the following inforrnationa) equipment capacity (input and output) and required maintenance actionsb) equipment operation and maintenance manuaisc) HVAC system control maintenance and calibration information, including wiring diagrams, schematics, and control sequence descriptions: desired or field -determined set points must be permanently recorded on control drawings, at control devices, or, for digital control systems, in programming commented) complete narrative of how each system is intended to operate. 12. Each supply air outlet or diffuser and each zone terminal device (such as VAV or mixing box) must have its own balancing device. Acceptable balancing devices include adjustable dampers located within the ductwork, terminal devices, and supply air diffusers. 13. Service water heating equipment must meet minimum Federal efficiency requirements included in the National Appliance Energy Conservation Act and the Energy Policy Act of 1992. which meet or exceed ASHRAE 90.1 Code New service water heating equipment can be assumed to meet these requirements, 14, Water -heating equipment must be provided with controls that allow the user to set the water temperature to 110 degrees F for dwelling units and 90 degrees F forother occupancies. Controls must limit output temperatures of lavatories in public facility restrooms to 110 degrees F. 15, Stair and elevator shaft vents must be equipped with motorized dampers capable of being automatically closed during normal building operation and Interlocked to open as required by fire and smoke detection systems. All gravity outdoor air supply and exhaust hoods, vents, and ventilators must be equipped with motorized dampers that will automatically shut when the spaces served are not in use. Exceptions., - Gravity (nor! -motorized) dampers are acceptable In buildings less than three stories In height above grade, - Ventilation systems serving unconditioned spaces, City of College Station Page AV00 Building Inspection Department PLANS EXAMINATION REPORT Address: Project Name: Aw Y''''1 Date: --2-11.2— of Drawing Number Code Ref. Number Questions or Comments fe (-- 7 r t tti t bC c�J�YC yc�v P Received by: Date: