HomeMy WebLinkAboutRES2007-00291, 07-304a
(3/3/2008) Kim Wolfe Re: CAling for CO for 5205 Ballybunion Ln
From: Terry Boriskie i
To: Amber Carter; Benjamin McCarty; Chris Haver; Gina Southerland; Joe G...
Date: 3/3/2008 8:33 AM
Subject: Re: CAlling for CO for 5205 Ballybunion Ln
Contacted Tommy Cole at 777-9641.
Terry Boriskie
City of College Station
Residential Plans Examiner
979-764-3744
>>> Joe Garcia 2/29/2008 5:20 pm >>>
No for CO. sewer box is buried. JMG
>>> Amber Carter 02/29/08 8:15 AM >>>
by 07-291
Any issues?
PREPARED
2/29/08,
7:56:39
INSPECTION TICKET
PAGE 3
City of
---------------------------
College Station
INSPECTOR: BUILDING INSPECTOR
DATE 2/28/08
ADDRESS
--------------------------------------------------------------------
. : 5205 BALLYBUNION
LN SUBDIV: PEBBLE CREEK
CONTRACTOR COLE FAMILY BUILDERS, INC PHONE (979) 696-1333
OWNER .
.
PHONE
PARCEL .
. 497900-0947-0130
APPL NUMBER: 07-00000291
------------------------------------------------------------------------------------------------
RESIDENTIAL, 1 UNIT DETACHED NEW
PERMIT:
BLDG 00 BUILDING PERMIT
REQUESTED
INSP
DESCRIPTION
TYP/SQ
COMPLETED
RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01
5/14/07
OC
BLDG, FOUNDATION -SLAB TIME: 17:00
5/14/07
AP
May 11, 2007 9:35:10 AM kwolfe.
Strings On Setbacks O.K.
Slab Ground Installed
B115 01
6/21/07
JGM
BLDG, FRAMING TIME: 17:00
6/22/07
AE
June 21, 2007 9:39:44 AM acarter.
06/22/2007 08:08 AM JGM PDA
need to fix previous notes on elec , hvac, and
plumbing
sheetrock over fireplace, fireblock) need joist
hanger
entry hall, dryer duct too long
B130 01
6/29/07
RH
BLDG, INSULATION TIME: 17:00
6/29/07
DP
June 28, 2007 1:48:55 PM glsouth.
06/29/2007 12:25 PM RH PDA
Did not fix framing notes.
B130 02
7/02/07
OC
BLDG, INSULATION TIME: 17:00
7/02/07
AP
July 2, 2007 8:15:33 AM acarter.
July 2, 2007 10:25:23 AM kwolfe.
B125 01
2 28`0G8
BLDG, FINAL TIME: 17:00
acI O 0
February 28, 2008 4:07:19 PM acarter.
-------------------------------------- COMMENTS AND NOTES --------------------------------------
Cn r o . aq45
�' � ° 1 � :-% $�'1-
Date: 2/29/2008
[nspection Comments for Final,
Permit Year: 7 'ermit Number: 291
Address: 5205 BALLYBUNION LN
Type
Inspection Type Code
Description
s atps
Inspection Result Comments
B100
BLDG, FOUNDATION-SU
IC
Strings On Setbacks O.K.
B100
BLDG, FOUNDATION-SL,
IC
Slab Ground Installed
B115
BLDG, FRAMING
IC
06/22/2007 08:08 AM JGM PDA
13115
BLDG, FRAMING
IC
need to fix previous notes on elec , hvac, and plumbing
13115
BLDG, FRAMING
IC
sheetrock over fireplace, fireblock) need joist hanger
13115
BLDG, FRAMING
IC
entry hall, dryer duct too long
B130
BLDG, INSULATION
IC
06/29/2007 12:25 PM RH PDA
B130
BLDG, INSULATION
IC
Did not fix framing notes.
B130
BLDG, INSULATION
IC
July 2, 2007 10:25:23 AM kwolfe.
M100
MECH, ROUGH IN
IC
06/15/2007 10:39 AM JGM PDA
M100
MECH, ROUGH IN
IC
bathroom exhaust duct needs to extend to soffit, need to
M100
MECH, ROUGH IN
IC
fix restricted ducts, hallway bath, foyer and utility room
P100
PLBG, ROUGH IN
IC
May 8, 2007 4:07:42 PM kwolfe.
Page 1
WFO873053 / 001 City of College Station
PAGE 1
REQ. DATE:
02/09/07
02/09/07
9:33:49
LOCATION:
5205 BALLYBUNION LN
LOC ID:
205862
REQUESTOR:
COLE FAMILY BUILDERS, INC ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER: KWOLFE
WORK TYPE:
ROUT
4" SWR
TAP 3/4" WTR TAP
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT SET
READY
SCHED START: 02/09/07 SCHED COMPLETION:
02/09/07
JOB ORDER
RESULT COMMNTS
29'-2 11 /16"
14'-0 5/8"
O
105.20'
00
n I� I
0' REAR SETBAC Ln
a
I
I
I
56'-9"
co
N
I
N
i
I
29'-10 11)�16" I,
i
/ M
B.S. �
I
N
doo doo
/0000,
37.34' Ile
5a05 BALLYBUNION LAP
SITE PLAN
„
SCALE: 1 =20 -0
I
PFRRI F CREEK
TEXAS SPCB TERMITE TREATMENT DISCLOSURE DOCUMENT
• i --
ration to be Treated•
COLE FAMILY BUILDERS
5205 BALLYBUNION
• •y.11 l . . -•
3997
rcentaae of Termticide(s)33 to be Applied at this location: 0.06%11GAL.
)e of Treatment: Full Partial XX vertical XX
HorizontallPerimeter Beam XX_
undation: SLAB Siding: BRICK
mary, Use: RESIDENCE Roof: COMPOSITION
3EL FOR ANY OTHER PESTICIDE RECOMENDED OR USED HAS BEEN ATTACHED AS PART OF THIS DOCUMENT. WARRANTY INFORMATION (IF ANY)
UDING AREA COVERED, 71ME PERIOD OF WARRANTY, RENEWAL OPTIONSAND COST, THE OBLIGATIONS OF THE PEST CONTROL OPERATOR TO RE-
kT FOR TERMITE INFESTATIONS OR REPAIR DAMAGE CAUSED BY TERMITE INFESTATIONS WITHIN THE WARRANTY PERIOD, AND THE CONDITIONS THAT
LD DEVELOP AS A RESULT OF THE OWNER'S ACTION OR INACTION THAT WOULD VOID THE WARRANTY HAS ALSO BEEN ATTACHED.
urges for pre -treat:
SEE ATTACHED SKETCH
BUILDERS SUPPLIES SKETCH/ PLAN
$6w.®®
)TES: Annual re-newal: $140.00
32129 PT
Co or Techincian SPCB license #
5/10/2007
32129 PT
B` l'LDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number
07-00000291
Date 2/09/07
Property Address . .
. . . . 5205 BALLYBUNION LN
Property ID:
497900-0947-0130
R #:
R
Application type description
RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . .
. . . . PEBBLE CREEK
Property Use . . . .
. . . . RESIDENTIAL
Property Zoning . . .
. . . . SINGLE FAMILY RESIDENTIAL
Application valuation
. . . . 265000
Owner
Contractor
------------------------
------------------------
COLE FAMILY BUILDERS,
INC
822 PINE VALLEY
DR
COLLEGE STATION
TX 77845
(979) 696-1333
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
3066.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
3.00
NUMBER OF BEDROOMS
4.00
SEWER TYPE
PUBLIC
TAZ
411.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
KE
Permit Fee . . . .
955.00 Plan Check Fee
.00
Issue Date . . . .
2/09/07 Valuation . .
. . 265000
Expiration Date . .
8/08/07
Qty Unit Charge Per Extension
BASE FEE 460.00
165.00 3.0000 THOU BLDG, VAL 100001-500000 495.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 2211
------------------------------------------------- --- - ----------------
BUILDING DEPT REPRESENTATIVE: - -
Dor
APPLIC
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page 2
Application Number . . . . . 07-00000291 Date 2/09/07
----------------------------------------------------------------------------
Special Notes and Comments
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
BUILDING DEPT REPRESENTATIVE:
APPLICANT: -- ��
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 07-00000291
Page 3
Date 2/09/07
Special Notes and Comments
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
----------------------------- ----/V -- --.- ------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page
4
Application Number . . . . . 07-00000291 Date
2/09/07
----------------------------------------------------------------------------
Special Notes and Comments
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
Narrow Wall Bracing Fully Sheathed with Interior Anchors and
Bracing per Plans and Modified Back Porch Windows to get 28"
Minimum OSB on each end of windows.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4" 350.00
WATER TAP 3/4" 400.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------------------------------
-----------------
Permit Fee Total 955.00 955.00 .00
.00
Plan Check Total .00 .00 .00
.00
Other Fee Total 750.00 750.00 .00
.00
Grand Total 1705.00 1705.00 .00
.00
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - 2- Al� - - - - - - - - - - -
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
07-00000304 Date
2/09/07
Property Address . . . . . .
5205 BALLYBUNION LN
Property ID:
497900-0947-0130
R #:
R
Application type description
TEMP POLE
Subdivision Name . . . . . .
PEBBLE CREEK
Property Use . . . . . . . .
RESIDENTIAL
Property Zoning . . . . . . .
SINGLE FAMILY RESIDENTIAL
Application valuation
0
Owner
Contractor
------------------------
------------------------
COLE FAMILY BUILDERS,
INC
822 PINE VALLEY DR
COLLEGE STATION
TX 77845
(979) 696-1333
----------------------------------------------------------------------------
Permit . . . . . . TEMP POLE
PERMIT
Additional desc . . KW
Permit Fee . . . . 20.00
Issue Date . . . . 2/09/07
Valuation . . . .
0
----------------------------------------------------------------------------
Fee summary Charged
Paid Credited
------------------------------
Due
---------------------------
Permit Fee Total 20.00
20.00 .00
.00
Grand Total 20.00
20.00 .00
.00
-
CITY OF COLLEGE STATION
Planning c5';Devdopmcdt Strvicer
ADDRESS/LOCATION:
APPLICATION' FOR BUILDING PERMIT
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
WWW.CSTX.GOV
DATE. 0 -0 5 0 TRCC REG
APPLICATION # 01— 16-1
TEMP POLE # � 04
LOT BLOCK �SUBDIVISION�b\��1i�� SEC/PH�
BUSINESS/OWNER NAME: C_ak'P0-0'1"AV PHONE:
CONTRACTOR/HOMEOWNER: —T-7 ml"^ A C a PHONE: -7 % % 4(0
CONTRACTOR ADDRESS:7t lIAS
ELECTRICIAN: �'� Uj ��eL�'R��4 PLUMBER: UJ@AG ?V Vv�
HVAC:GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ONLY
DUPLEX (Landscape Plans) REMODEL/RENOVATION* SWIMMING POOL
TENT/CANOPY
DESCRIPTION OF WORK: 1xe.\,.3
PROPOSED USE:
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TA S PROJECT REGISTRATION# EABPRJ
VALUATION: $ Zko-S-000 (� TOTAL AREA: W) HEATED AREA: 3000
(Cost of Labor and Materials)
PUBLIC SEWER
SEPTIC/TREATMENT SYSTEM
SEWER TAP: 411
Slz .
WATER TAP: A `!
SIZE
OTHER TAP: _
TEMP POLE
GARAGE TYPE: SINGLE Fj
ATTACHED
NZE
NUMBER OF BEDROOMS: Li
NUMBER OF BATHROOMS: 3
INTERIOR WALL TYPE
EXTERIOR WALL TYPE
FOUNDATION TYPE:
ROOF TYPE:
5)m!ArC_4k
DOUBLE � TRIPLE a
DETACHED F-1 CARPORT
SIGNATURE OF APPLICANT—
*If proposed work involves new commercial construction or facade improvements/renovations to an existing
commercial property, building elevations are required.
Official Use Only
Plans Examiner Zoning Official
C ents:
jflFSJor NO
V
Fire Marshall
;g r MTN 00
Energy Code Compliance Information
% Glazing of exterior walls Mb
Insulation R value of exterior walls / 3
Insulation R value of ceiling 1 (flat areas) 3 O
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC qO ✓
Glazing U-Factor y
R value of ductwork
A/C SEER Rating
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# 0'7 - J51 DATE: o2-6 ✓z) %
BUILDING ADDRESS:
I. Foundation Requirements
N
A.
Concrete minimum f'c of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier 6 mil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior unless over 60' Ion
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F.
Wood foundation details indicated
K
II. Framing: Floor, Wall, Ceiling and Roof Requirements
RN M
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
OK
1. One -hour rated extending to roof deck
@AVOK
E.
Header sizes indicated on plans
F.
Emergency bedroom egress
1. Exit direct to outside
2. O enable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
O enable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
N.
O.
P.
Span exceeding code tables must be engineered
Rafter size and spacing and purlin bracing indicated.
Roof covering used.
Indicate Wall Bracing Used for Lateral Bracing
M
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
II. Framing: Floor, Wall, Ceiling and Roof Requirements continued
N
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
S.
T.
18" Overhang allowed on zero lot line construction, perforated soffit allowed.
Protected openings on walls < three feet from property line
OK
V�-
III. Stairway Requirements
tNAYOK
A.
Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" diff. max.
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B.
Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C.
Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches above handrail
4. Headroom required not less than six ft six 6-6 inches
\
5. All treads must be identical
D.
Guards/handrail details
j
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located four or more risers above floor/grade
j
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four (4) inch sphere
IV. Fireplace
Requirements (to be indicated onplans)
N
A.
Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B.
Masonry fireplace requires 2" clearance from all combustible materials
C.
Chimneys must extend at least three (3) feet higher than the highest point where it
projects through the roof of a building & at least two (2) feet higher than any portion of the
building within ten (10) feet horizontal
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
V. Electrical Service Requirements
NAfft
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
VI. Plumbing Requirements
N
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
N
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N
Maximum drive width for residence is 25' combined for circular 12' minimum
Minimum 20 feet from driveway to side(intersecting) street
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
N
Does not block any water course or divert any flow
Elevation certificate needed
[-40K
__4 11
PLANS EXAMINER
"APPROVED PLANS PER IRC SECTION R106.3.1."
c c) -7