INSPECTION TICKET
PAGE 1
City of
------------------------------------------------------------------------------------------------
College Station
INSPECTOR: BUILDING INSPECTOR
DATE 4/01/08
ADDRESS
4727 JOHNSON CREEK
LOOP SUBDIV: WILLIAMS CREEK PH
3
CONTRACTOR ACKLAM
CONSTRUCTION, INC. PHONE (979) 690-8500
OWNER
ACKLAM,
SHAWN N & HALEY PHONE
PARCEL
660050-0301-0230
APPL NUMBER: 07-00000282
------------------------------------------------------------------------------------------------
RESIDENTIAL, 1 UNIT DETACHED NEW
PERMIT:
BLDG 00 BUILDING PERMIT
REQUESTED
INSP
DESCRIPTION
TYP/SQ
COMPLETED
RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B105 01
2/12/07
JGM
BLDG, FOUNDATION -PIER TIME: 17:00
2/12/07
AP
February 9, 2007 3:14:31 PM ncochran.
B100 01
2/21/07
RH
BLDG, FOUNDATION -SLAB TIME: 17:00
2/21/07
AP
February 20, 2007 3:01:05 PM glsouth.
02/21/2007 11:49 AM. RH PDA
Lower rear grade beams. Strings up on setbacks.
Slab
ground needed by final pour.
B100 02
3/01/07
RH
BLDG, FOUNDATION -SLAB TIME: 17:00
3/01/07
AP
February 28, 2007 4:42:50 PM kwolfe.
on beam inspection - pouring at 3:30 (fyi)
early afternoon
03/01/2007 03:15 PM RH PDA
Will be installing a grounding grid as per Shawn.
B100 03
3/02/07
OC
BLDG, FOUNDATION -SLAB TIME: 17:00
3/02/07
AP
March 2, 2007 9:58:48 AM ncochran.
1st floor grade beams
B100 04
4/04/07
JGM
BLDG, FOUNDATION -SLAB TIME: 17:00
4/04/07
AP
April 4, 2007 9:33:44 AM kwolfe.
basement slab topping
B120 01
6/14/07
JGM
BLDG, FRAMING -PARTIAL TIME: 17:00
6/14/07
CA
June 14, 2007 11:30:07 AM glsouth.
SEE CHRIS BEFORE YOU GO OUT TO INSPECT.
06/14/2007 04:44 PM JGM PDA
courtesy walk through
B120 02
6/20/07
JGM
BLDG, FRAMING -PARTIAL TIME: 17:00
6/20/07
AP
June 19, 2007 12:25:12 PM acarter.
EXTERIOR GARAGE AND BASEMENT WALLS
06/20/2007 12:12 PM JGM PDA
exterior for brick, upper garage and basement areas
B120 03
6/22/07
JGM
BLDG, FRAMING -PARTIAL TIME: 17:00
6/22/07
AP
June 22, 2007 8:21:54 AM acarter.
LEFT EXT. MASTER BATH & MASTER BED
06/22/2007 04:20 PM JGM PDA
exterior sheathing for brick, west -wall around
master bath
B120 04
7/03/07
OC
BLDG, FRAMING -PARTIAL TIME: 17:00
7/03/07
AP
July 2, 2007 12:56:15 PM acarter.
EXTERIOR WALLS
B115 01 10/12/07 JGM BLDG, FRAMING TIME: 17:00
10/12/07 AP September 19, 2007 2:07:00 PM acarter.
AFTERNOON
B120 05 10/12/07 JGM BLDG, FRAMING -PARTIAL TIME: 17:00
10/16/07 AP October 12, 2007 1:22:10 PM glsouth.
PARTIAL FOR BASEMENT & GARAGE
B120 06 10/17/07 JGM BLDG, FRAMING -PARTIAL TIME: 17:00
10/17/07 AP October 16, 2007 2:20:08 PM acarter.
B130 01 10/29/07 OC BLDG, INSULATION TIME: 17:00
10/29/07 AP October 29, 2007 10:37:27 AM acarter.
B125 01 4 01/08 n BLDG, FINAL TIME: 17:00
April 1, 2008 3:26:37 PM kwolfe.
-------------------------------------- COMMENTS AND NOTES --------- --
V w
Date: 4/2/2008
[nspection Comments for Final,
Permit Year: 7 permit Number: 282
Address: 4727 JOHNSON CREEK LOOP
Type
Inspection Type Code
Description
Ins
Status
Inspection Result Comments
B100
BLDG, FOUNDATION-SL,
IC
02/21/2007 11:49 AM RH PDA
B100
BLDG, FOUNDATION-SL,
IC
Lower rear grade beams. Strings up on setbacks. Slab
B100
BLDG, FOUNDATION-SLi
IC
ground needed by final pour.
B100
BLDG, FOUNDATION-SLi
IC
03/01/2007 03:15 PM RH PDA
B100
BLDG, FOUNDATION-SV
IC
Will be installing a grounding grid as per Shawn.
B120
BLDG, FRAMING-PARTIF
IC
06/14/2007 04:44 PM JGM PDA
B120
BLDG, FRAMING-PARTIP
IC
courtesy walk through
B120
BLDG, FRAMING-PARTIF
IC
06/20/2007 12:12 PM JGM PDA
B120
BLDG, FRAMING-PARTIP
IC
exterior for brick, upper garage and basement areas
B120
BLDG, FRAMING-PARTIP
IC
06/22/2007 04:20 PM JGM PDA
B120
BLDG, FRAMING-PARTIP
IC
exterior sheathing for brick, west wall around master bath
E150
ELEC, FINAL
IC
March 25, 2008 12:43:46 PM kwolfe.
E150
ELEC, FINAL
IC
btu - on and running
M110
MECH, FINAL
IC
March 25, 2008 12:44:05 PM kwolfe.
M110
MECH, FINAL
IC
need proper access to upper furnance in attic and proper
M110
MECH, FINAL
IC
combustion air for laundry room by final.
M110
MECH, FINAL
IC
Space between door and concrete will count for
M110
MECH, FINAL
IC
air requirements at bottom.
M110
MECH, FINAL
IC
Ladder will be built for upper unit.
P100
PLBG, ROUGH IN
IC
June 19, 2007 8:54:42 AM acarter.
PLBG, FINAL
IC
March 25, 2008 12:43:14 PM kwolfe.
IP125
P1251PLBG,
FINAL I
IC Ineed
combustion air for laundry room by final
Page 1
Amber Carter - Re. Calhng_for C O. @ 4727 Johnson Creek Page 1
From: Paul Schoenfeld
To: Amber Carter; Benjamin McCarty; Chris Haver; ...
Date: 4/3/2008 7:48 am
Subject: Re: Calling for C.O. @ 4727 Johnson Creek
ALL OK.
PAUL
>>> Gina Southerland 4/2/2008 8:15 AM >>>
BP# 07-282
Gina Southerland
CSR - Planning & Development Services
City of College Station
979-764-3570
www.csbc.gov
t U.S. DEPARTMENT OF HOMELAND SECURITY ELEVATION CERTIFICATE OMB No. 1660-0008
Federal Emergency Management Agency I Exoires February 28. 2009
National Flood Insurance Program Important: Read the instructions on pages 1-8.
SECTION A - PROPERTY INFORMATION For Insurance Company Use:
Al. Building Owner's Name Shawn & Haley Acklam Policy Number
A2. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. I Company NAIC Number I
4727 Johnson Creek Loop
City College Station State TX ZIP Code 77845
A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.)
Lot 23, Block 1, Williams Creek Subdivision, Phase 3, Vol. 7249, Pg. 292
A4. Building Use (e.g., Residential, Non -Residential, Addition, Accessory, etc.) Residential
A5. Latitude/Longitude: Lat. 30-34-45 N Long. 96-13-00 W Horizontal Datum: ❑ NAD 1927 ® NAD 1983
A6. Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance.
A7. Building Diagram Number 7
A8. For a building with a crawl space or enclosure(s), provide A9. For a building with an attached garage, provide:
a) Square footage of crawl space or enclosure(s) 1595 sq ft a) Square footage of attached garage 965 sq ft
b) No. of permanent flood openings in the crawl space or b) No. of permanent flood openings in the attached garage
enclosure(s) walls within 1.0 foot above adjacent grade 0 walls within 1.0 foot above adjacent grade 0
c) Total net area of flood openings in A8.b 0 sq in c) Total net area of flood openings in A9.b 0 sq in
SECTION B - FLOOD INSURANCE RATE MAP (FIRM) INFORMATION
B1. NFIP Community Name & Community Number B2. County Name B3. State
City of College Station 480083 1 Brazos I TX
B4. Map/Panel Number
B5. Suffix
B6. FIRM Index
B7. FIRM Panel
B8. Flood
B9. Base Flood Elevation(s) (Zone
Date
Effective/Revised Date
Zone(s)
AO, use base flood depth)
48041CO205 C 205
C
July 02, 1992
July 02, 1992
AE
212
B10. Indicate the source of the Base Flood Elevation (BFE) data or base flood depth entered in Item B9.
❑ FIS Profile ® FIRM ❑ Community Determined ❑ Other (Describe)
B11. Indicate elevation datum used for BFE in Item 139: ® NGVD 1929 ❑ NAVD 1988 ❑ Other (Describe)
B12. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? ❑Yes ®No
Designation Date ❑ CBRS ❑ OPA
SECTION C - BUILDING ELEVATION INFORMATION (SURVEY REQUIRED)
Cl. Building elevations are based on: ❑ Construction Drawings* ❑ Building Under Construction* ® Finished Construction
*A new Elevation Certificate will be required when construction of the building is complete.
C2. Elevations - Zones Al-A30, AE, AH, A (with BFE), VE, V1-V30, V (with BFE), AR, AR/A, AR/AE, AR/A1-A30, AR/AH, AR/AO. Complete Items C2.a-g
below according to the building diagram specified in Item A7.
Benchmark Utilized N/A Vertical Datum NAVD88 - Geoid - GPS
Conversion/Comments In this area of Texas, (Latitued-30 deg. Longitude-96 deg) difference in datum is negligible (<0.05')
Check the measurement used.
a) Top of bottom floor (including basement, crawl space, or enclosure floor)_
b) Top of the next higher floor
c) Bottom of the lowest horizontal structural member (V Zones only)
d) Attached garage (top of slab)
e) Lowest elevation of machinery or equipment servicing the building
(Describe type of equipment in Comments)
f) Lowest adjacent (finished) grade (LAG)
g) Highest adjacent (finished) grade (HAG)
220.48
® feet
❑ meters (Puerto Rico only)
225.06
® feet
❑ meters (Puerto Rico only)
❑ feet
❑ meters (Puerto Rico only)
235.50
® feet
❑ meters (Puerto Rico only)
223.92
® feet
❑ meters (Puerto Rico only)
223.89
® feet
❑ meters (Puerto Rico only)
234.43
Z feet
❑ meters (Puerto Rico only)
SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION
This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation
information. 1 certify that the information on this Certificate represents my best efforts to interpret the data available.
/ understand that any false statement may be punishable by fine or imprisonment under 18 U.S. Code, Section 1001.
® Check here if comments are provided on back of form.
Certifier's Name S.M. Kling, RPLS License Number 2003
Land Surveyor Company
ng
Address 4101 S. Texas Ave. Suite A City Bryan State TX ZIP Code 77802
FEMA Form 81-31, Febru_apf✓1006 See reverse side for continuation. Replaces all previous editions
IMPORTANT: In these spaces, copy the corresponding information from Section A. For Insurance Company Use:
Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number
4727 Johnson Creek Loop
City College Station State TX ZIP Code 77845 Company NAIC Number
SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION (CONTINUED)
Copy both sides of this Elevation Certificate for (1) community official, (2) insurance agent/company, and (3) building owner.
Comments tem A9.a-Attached Garage square footage - multiple garage space; square footage is for largest garage (3 car garage)
Item C2.a-Elevation of basement at sump/crawl space.
Item C2.b-Elevation of basement - Elevation of next higest floor = 235.52
Item C2.e-Elevation of Equipment - multiple a/c units; elevation is for lowest a/c pad
Signature Date
❑ Check here if attachments
SECTION E - BUILDING ELEVATION INFORMATION (SURVEY NOT REQUIRED) FOR ZONE AO AND ZONE A (WITHOUT BFE)
For Zones AO and A (without BFE), complete Items El-E5. If the Certificate is intended to support a LOMA or LOMR-F request, complete Sections A, B,
and C. For Items E1-E4, use natural grade, if available. Check the measurement used. In Puerto Rico only, enter meters.
E1. Provide elevation information for the following and check the appropriate boxes to show whether the elevation is above or below the highest adjacent
grade (HAG) and the lowest adjacent grade (LAG).
a) Top of bottom floor (including basement, crawl space, or enclosure) is ❑ feet ❑ meters ❑ above or ❑ below the HAG.
b) Top of bottom floor (including basement, crawl space, or enclosure) is ❑ feet ❑ meters ❑ above or ❑ below the LAG.
E2. For Building Diagrams 6-8 with permanent flood openings provided in Section A Items 8 and/or 9 (see page 8 of Instructions), the next higher floor
(elevation C2.b in the diagrams) of the building is ❑ feet ❑ meters ❑ above or ❑ below the HAG.
E3. Attached garage (top of slab) is ❑ feet ❑ meters ❑ above or ❑ below the HAG.
E4. Top of platform of machinery and/or equipment servicing the building is ❑ feet ❑ meters ❑ above or ❑ below the HAG.
E5. Zone AO only: If no flood depth number is available, is the top of the bottom floor elevated in accordance with the community's floodplain management
ordinance? ❑ Yes ❑ No ❑ Unknown. The local official must certify this information in Section G.
SECTION F - PROPERTY OWNER (OR OWNER'S REPRESENTATIVE) CERTIFICATION
The property owner or owner's authorized representative who completes Sections A, B, and E for Zone A (without a FEMA-issued or community -issued BFE)
or Zone AO must sign here. The statements in Sections A, B, and E are correct to the best of my knowledge.
Property Owner's or Owner's Authorized Representative's Name
Shawn Acklam
Address 4727 Johnson Creek Loop City College Station State TX ZIP Code 77845
Signature Date Telephone
Comments
❑ Check here if attachments
SECTION G - COMMUNITY INFORMATION (OPTIONAL)
The local official who is authorized by law or ordinance to administer the community's floodplain management ordinance can complete Sections A, B, C (or E),
and G of this Elevation Certificate. Complete the applicable item(s) and sign below. Check the measurement used in Items G8. and G9.
G1. ❑ The information in Section C was taken from other documentation that has been signed and sealed by a licensed surveyor, engineer, or architect who
is authorized by law to certify elevation information. (Indicate the source and date of the elevation data in the Comments area below.)
G2. ❑ A community official completed Section E for a building located in Zone A (without a FEMA-issued or community -issued BFE) or Zone AO.
G3. ❑ The following information (Items G4.-G9.) is provided for community floodplain management purposes.
G4. Permit Number G5. Date Permit Issued G6. Date Certificate Of Compliance/Occupancy Issued
G7. This permit has been issued for: ❑ New Construction ❑ Substantial Improvement
G8. Elevation of as -built lowest floor (including basement) of the building: _❑ feet ❑ meters (PR) Datum
G9. BFE or (in Zone AO) depth of flooding at the building site: ❑ feet ❑ meters (PR) Datum
Local Official's Name Title
Community Name Telephone
Signature Date
Comments
❑ Check here if attachments
FEMA Form 81-31, February 2006 Replaces all previous editions
Building Photographs
See Instructions for Item A6.
For Insurance Company Use:
Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number
4727 Johnson Creek Loop
City College Station State Tx ZIP Code 77845 Company NAIC Number
If using the Elevation Certificate to obtain NFIP flood insurance, affix at least two building photographs below according to
the instructions for Item A6. Identify all photographs with: date taken; "Front View" and "Rear View"; and, if required, "Right
Side View" and "Left Side View." If submitting more photographs than will fit on this page, use the Continuation Page,
following.
Front View —Taken 12-20-07:
Rear View —Taken 12-20-07:
f
r
Building Photographs
Continuation Page
For Insurance Company Use:
Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number
4727 Johnson Creek Loop
City College Station State Tx ZIP Code 77845 Company NAIC Number
If submitting more photographs than will fit on the preceding page, affix the additional photographs below. Identify all
photographs with: date taken; "Front View" and "Rear View"; and, if required, "Right Side View" and "Left Side View."
Riaht Side View — Taken 12-20-07
Left Side and FrontView— Taken 12-20-07
r -
A*6k
College Station Fire Department
to=
INSPECTIONITEST REQUEST
`i'7 ,� Se nSon Cc-eek LooP
Location of Inspection/Test:- � �` 17 -7 yS
C,plle •02 �X
Business/Job Phone: O rt '�) 6 9 0 - 0,
Applicant Name: �a� r�cc� /��A�amo��;c'r�_ ����>, �r/°seS ._ 1�IC -
Address: J1 Icz- tog
Co11 ea'p 5 c I X 9 0 q a.
Phone: Lg rr.gi wt o - 03O; Date of Application: _ 9 - // - o 7
INSPECTION/TEST FEE AMT. DUE
Day Care Inspection......................................................................... $30.00 .......:..:....$
FosterHome Inspection................................................................... $30.00 .............. $
Nursing Home Inspection..:............................................................... $50.00 ..............
$
Health Care Facility Inspection .............._,__.. _.............................. $50.00..............
$
.
Fire Sprinkler/Standpipe Test, up to 100..................+�................ $50.00 ..............
_ o
$ O
Each 100 thereafter, or fraction ..... # heads @ $5A.00/100 ..............
$
Automatic Hood Fire Extinguisher Test ............................................ $30.00 ..............
$
FuelTank Leak Test.:....................................................................... $50.00 ..............
$
FuelLine Leak Test.......................................................................... $50.00 ..............
$
Automatic Fire Alarm System Test, up to 25 initiating devices ......... $30.00 ...............
$
Each 100 thereafter, orfraction ....# devices @ $50.00/100 ..............
$
Natural Gas System Test.................................................................. $30.00 ..............
$
Inspections Outside City Limits
Standard Fee: x 1.5 =
Vehicle Mileage: x 0.325 =
Total Travel Time: x 20.00 =
Total Inspection Fee:
$ `� O
TOTAL AMOUNT DUE:
$ 5 ��
5
PLEASE NOTE: Re -tests and re -inspections will be billed at the same rate as the initial test or inspection.
White: Applicant Yellow: Fire Marshal
A.---
pink: Building
--
CITY OFECOLLEGE NSTATION
*** CUSTOMER RECEIPT ***
Oper: KWOLFE Type: CT Drawer: I
Date: 9/11/07 00 Receipt no: 381645
Quantity Amount
Description FIRE SPRINKLER SYSTEM/001
F8 1.00 $50.00
STANDARDAUTOMATICFIRE
TEST
FIRE
KW
CK 1591
Tender detail 1591 $50.00
CK PERSONAL $50.00
Total tendered $50.00
Total payment
Trans date: 9/11/07 Time: 10*10:40
THANK YOU
U.S. DEPARTMENT OF HOMELAND SECURITY ELEVATION CERTIFICATE OMB No. 1660-0008
Federla 6pergtq Management Agency ExDires February 28. 2009
National Flood Insurance Program Important: Read the instructions on pages 1-8.
SECTION A - PROPERTY INFORMATION for Insurance Company Use
Al Building Owner's Name Shawn & Haley Acklam Policy Number
A2. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Company NAIC Number
4727 Johnson Creek Loop
City College Station State TX ZIP Code 77845
A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.)
Lot 23, Block 1, Williams Creek Subdivision Phase 3
A4. Building Use (e.g., Residential, Non -Residential, Addition, Accessory, etc.) Residential
A5. Latitude/Longitude: Lat. 30-34-45 N Long. 96-13-00 W Horizontal Datum: ❑ NAD 1927 ® NAD 1983
A6. Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance.
AT Building Diagram Number 7
A8. For a building with a crawl space or enclosure(s), provide A9. For a building with an attached garage, provide:
a) Square footage of crawl space or enclosure(s) 1595 sq ft a) Square footage of attached garage 965 sq ft
b) No. of permanent flood openings in the crawl space or b) No. of permanent flood openings in the attached garage
enclosure(s) walls within 1.0 foot above adjacent grade 0 walls within 1.0 foot above adjacent grade 0
c) Total net area of flood openings in A8.b 0 sq in c) Total net area of flood openings in A9.b 0 sa in
btc I ION 13 - FLOOD INSURANCE RATE MAP (FIRM) INFORMATION
B1. NFIP Community Name & Community Number B2. County Name B3. State
City of College Station 480083 Brazos TX
B4. Map/Panel Number
65. Suffix
B6. FIRM Index
B7. FIRM Panel
B8. Flood
B9. Base Flood Elevation(s) (Zone
48041CO205 C 205
C
Date
July 02, 1992
Effective/Revised Date
July 02,
Zone(s)
AO, use base flood depth)
1992
AE
212
Gin L.d•....a.. 16
Me SGUrCe Oi Me Base rood mievation (BFE) data or base Hood depth entered in Item B9.
❑ FIS Profile ® FIRM ❑ Community Determined ❑ Other (Describe)
Bl 1. Indicate elevation datum used for BFE in Item 69: ® NGVD 1929 ❑ NAVD 1988 ❑ Other (Describe)
B12. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? ❑Yes ®No
Designation Date ❑ CBRS ❑ OPA
btc:I IUN c - BUILDING ELEVATION INFORMATION (SURVEY REQUIRED)
Cl. Building elevations are based on: I@ Construction Drawings' ❑ Building Under Construction' ❑ Finished Construction
'A new Elevation Certificate will be required when construction of the building is complete.
C2. Elevations -Zones Al-A30, AE, AH, A (with BFE), VE, V1-V30, V (with BFE), AR, AR/A, AR/AE, AR/A1-A30, AR/AH, AR/AO. Complete Items C2.a-g
below according to the building diagram specified in Item AT
Benchmark Utilized N/A Vertical Datum NAVD88 - Geoid - GPS
Conversion/Comments In this area of Texas. (Latitued-30 deg Longitude-96 deg) difference in datum is negligible (<0 05')
Check the measurement used.
a) Top of bottom floor (including basement, crawl space, or enclosure floor)_
b) Top of the next higher floor
c) Bottom of the lowest horizontal structural member (V Zones only)
d) Attached garage (top of slab)
e) Lowest elevation of machinery or equipment servicing the building
(Describe type of equipment in Comments)
f) Lowest adjacent (finished) grade (LAG)
g) Highest adjacent (finished) grade (HAG)
224.7
® feet
❑ meters (Puerto Rico only)
235.5
® feet
❑ meters (Puerto Rico only)
_
❑ feet
❑ meters (Puerto Rico only)
235.5
❑ feet
❑ meters (Puerto Rico only)
234.0
❑ feet
❑ meters (Puerto Rico only)
234.0
❑ feet
❑ meters (Puerto Rico only)
236.0
❑ feet
❑ meters (Puerto Rico only)
SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION
This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation
information. l certify that the information on this Certificate represents my best efforts to interpret the data available.
l understand that any false statement may be punishable by fine or imprisonment under 18 U. S. Code, Section 1001.
❑ Check here if comments are provided on back of forth.
Certifier's Name S.M. Kling, RPLS License Number 2003
Title Registered Professional Land Surveyor Company Name Kling Engineering & Surveying
rcivar% roan o i-J i, reDruary LUub
See reverse side for continuation.
9
Replaces all previous editions
IMPORTANT: In these spaces, copy the corresponding information from Section A. For Insurance Company Use:
Building Str' ee Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number
4727 Johnson Creek Loop
City College Station State TX ZIP Code 77845 Company NAIC Number
SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION (CONTINUED)
Copy both sides of this Elevation Certificate for (1) community official, (2) insurance agent/company, and (3) building owner.
Signature Date
❑ Check here if attachments
SECTION E - BUILDING ELEVATION INFORMATION (SURVEY NOT REQUIRED) FOR ZONE AO AND ZONE A (WITHOUT BFE)
For Zones AO and A (without BFE), complete Items El-E5. If the Certificate is intended to support a LOMA or LOMR-F request, complete Sections A, B,
and C. For Items El-E4, use natural grade, if available. Check the measurement used. In Puerto Rico only, enter meters.
E1. Provide elevation information for the following and check the appropriate boxes to show whether the elevation is above or below the highest adjacent
grade (HAG) and the lowest adjacent grade (LAG).
a) Top of bottom floor (including basement, crawl space, or enclosure) is ❑ feet ❑ meters ❑ above or ❑ below the HAG.
b) Top of bottom floor (including basement, crawl space, or enclosure) is ❑ feet ❑ meters ❑ above or ❑ below the LAG.
E2. For Building Diagrams 6-8 with permanent flood openings provided in Section A Items 8 and/or 9 (see page 8 of Instructions), the next higher floor
(elevation C2.b in the diagrams) of the building is ❑ feet ❑ meters ❑ above or ❑ below the HAG.
E3. Attached garage (top of slab) is ❑ feet ❑ meters ❑ above or ❑ below the HAG.
E4. Top of platform of machinery and/or equipment servicing the building is ❑ feet ❑ meters ❑ above or ❑ below the HAG.
E5. Zone AO only: If no flood depth number is available, is the top of the bottom floor elevated in accordance with the community's floodplain management
ordinance? ❑ Yes ❑ No ❑ Unknown. The local official must certify this information in Section G.
SECTION F - PROPERTY OWNER (OR OWNER'S REPRESENTATIVE) CERTIFICATION
The property owner or owner's authorized representative who completes Sections A, B, and E for Zone A (without a FEMA-issued or community -issued BFE)
or Zone AO must sign here. The statements in Sections A, B, and E are correct to the best of my knowledge.
Property Owner's or Owner's Authorized Representative's Name
Shawn Acklam
Address 1 Forest Drive City College Station State TX ZIP Code 77840
Signature Date Z1 -/07 Telephone9,9 -lbZ-o - \ 6bo
Comments
❑ Check here if attachments
SECTION G - COMMUNITY INFORMATION (OPTIONAL)
The local official who is authorized
and G of this Elevation Certificate.
The information in Section C was taken from other documentation that has been signed and sealed by a licensed surveyor, engineer, or architect who
is authorized by law to certify elevation information. (Indicate the source and date of the elevation data in the Comments area below.)
A community official completed Section E for a building located in Zone A (without a FEMA-issued or community -issued BFE) or Zone AO.
G1. ❑
G2. ❑
G3. ❑
or ordinance to administer the community's floodplain management oramance can compiew of
ete the applicable item(s) and sign below. Check the measurement used in Items G8. and G9.
The following information (Items G4.-G9.) is provided for community floodplain management purposes.
G4. Permit Number
G5. Date Permit Issued
A,
G6. Date Certificate Of Compliance/Occupancy Issued
G7. This permit has been issued for: ❑ New Construction ❑ Substantial Improvement
G8. Elevation of as -built lowest floor (including basement) of the building: _❑ feet ❑ meters (PR) Datum
G9. BFE or (in Zone AO) depth of flooding at the building site: ❑ feet ❑ meters (PR) Datum
Local Official's Name Title
Community Name Telephone
Date
Signature
Comments
❑ Check here if att7
Replaces all previ
FEMA Form 81-31, February 2006
MAY.21.2007 4:04PM Brazos County Health Department NO-6407 P. 2
Brazos County Health Department
201 North Texas Ave.
Bryan, TX 77803-5317 d
(979)361-4440
LICENSE TO OPERATE AN ON SITE SEWAGE FACILITY
THIS IS TO CERTIFY that the on site sewage facility owned by: OSSF #: 2007 - 2706
ACKLAM, SHAWN L
JOHNSON CREEK LOOP 4727, College Station TX 77845 Grid: 01"ti
WILLIAMS CREEK
Block: Lot: Certificate of Compliance: IN CS.
Installed By: GREENSAGE, JEFF Bedrooms: 2
Engineered By: GONZALEZ, STEVEN- PREMIER ENVIRONMENTAL DESIGNS Employees: 0
Date Purchased: 05/17/07 Final Inspection Date: 05/21/07 MaxGPD: 519
Disinfectant: Chlorine
The private sewage facility licensed above was installed according to the current and
minimum guidelines of the Texas Commission on Environmental Quality (TCEQ) and
Brazos County.
This aerobic system with spr�spersal requires a disinfectant for final treatment of the
sprayed effluent. It is the responsibility of the homeowner to monitor the disinfectant
and to add more when needed. (Swimming pool chlorine tablets are not acceptable
substitutes). Under no circumstance are any food crops or edible foods.to be grown in
Me spray area. Mowing of the sp:rayfield on a regular basis should also be done to help
with the evaporation process.
The current maintenance contract for this system will expire 2-years from the above final
inspection date. A new maintenance contract must be in force at that time, and a copy of
the new contract filed with this office 30 days before contract expires.
This is a NON -TRANSFERABLE license. Upon transfer of ownership, the new owner
shall be required to transfer the original license into his/her name_ Should the system
malfunction in the future, it will be the licensee's responsibility to bring the system in
compliance with all current state and county regulations.
This license does not extend to the material's, workmanship, or fabrication, of the
system, so as to expressly or impliedly grant the owner, or installer of the system any
warranty by / or rights against Brazos County and / or the Brazos County Health
Department, as to the quality or durability of the system, nor compliance with licensee's
individual specifications and requirements, but solely relates to the system meeting the
requirements of the.above named regulatory body in effect as of this date..
SPRAY AREA MUST BE CLEARED OF YAUPON AND SODDED OR SEEDED WITH GRASS.
SPRAYFIELD SHOULD BE MOWED AS NECESSARY TO MAINTAIN OPTIMUM CONDITIONS.
"�'�, �aSo��s 7Co7
R-10
Environmental Health Specialist
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979) 764-3�576 FAX: (979) 764-3496
----------------------------------------------------------------------------
Application Number-
07-00000282
Date 2/06/07
Property Address . . .
. . . 4727 JOHNSON CREEK LOOP
Property ID:
660050-0301-0230
R #:
R303818
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . .
. . . WILLIAMS CREEK PH 3
Property Use . . . . .
. . . RESIDENTIAL
Property Zoning . . . .
. . . RURAL RESIDENTIAL SUB.
Application valuation .
. . . 300000
Owner
Contractor
------------------------
ACKLAM, SHAWN N & HALEY
------------------------
ACKLAM CONSTRUCTION, INC.
1 FOREST DR
18932 SH 6 S
COLLEGE STATION TX
77840 COLLEGE STATION
TX 77845
(979) 690-8500
--- Structure Information 000 000 SINGLE FAMILY
Construction Type . . .
. . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . .
. . RESIDENTIAL-SFR/DUPLEX
Other struct info . . .
. . EXTERIOR WALL TYPE
2X6
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
3.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
4187.00
INTERIOR WALL TYPE
2X4
NUMBER OF BATHROOMS
4.50
NUMBER OF BEDROOMS
4.00
SEWER TYPE
SEPTIC
TAZ
329.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . . KW
Permit Fee . . . .
1060.00 Plan Check Fee
.00
Issue Date . . . .
2/06/07 Valuation . .
. . 300000
Expiration Date . .
8/05/07
Qty Unit Charge Per Extension
BASE FEE 460.00
200.00 3.0000 THOU BLDG, VAL 100001-500000 600.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTERS)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 2211
------------------------------------------------ ------ --- ----- -_-------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE,STATION, TX 77840
PHONE: (979)764-357d FAX: (979)764-3496
Page 2
Application Number . . . . . 07-00000282 Date 2/06/07
------------------------------------ 7---------------------------------------
Special Notes and Comments
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
OBTAIN HEALTH DEPARTMENT APPROVAL: CALL 979-361-4440 FOR
MORE INFORMATION. THIS INCLUDES SEPTIC SYSTEMS INSTALLS.
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
BUILDING DEPT REPRESENTATIVE:
APPLICANT: `�
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 3
Application Number . . . . . 07-00000282 Date 2/06/07
----------------------------------------------------------------------------
Special Notes and Comments
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 150 of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
------------------------------------------------ ----- --- ----
BUILDING DEPT REPRESENTATIVE: •
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 07-00000282
Page 4
Date 2/06/07
Special Notes and Comments
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
STAIRS SHALL COMPLY WITH SECTION R-311 (2003 IRC) WITH A
CONTINUOUS HANDRAIL OR SECTION
1009 (2003 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL
NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A
NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND
LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003
IRC)
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
Elevation Certificate Required MINIMIUM F.F. 213.0
12" Culvert Required.
ENGINEERED PIERS, SLAB AND CMU BLOCK WALLS
SEPTIC SYSTEM
For all walls other than CMU block walls to be Fully
Sheathed with OSB or Plywood.
ELEVATION CERTIFICATE REQUIRED - PROVIDE ELEVATION
CERTIFICATE PRIOR TO SLAB INSPECTION AND A SECOND
CERTIFICATE PRIOR TO FINAL INSPECTION/C.O.
Fee summary Charged Paid Credited Due
---------------------------------------------------------
Permit Fee Total 1060.00 1060.00 .00 .00
Plan Check Total .00 .00 .00 .00
Grand Total 1060.00 1060.00 .00 .00
-------------------------------- ------ - -- ---------
BUILDING DEPT REPRESENTATIVE:
13
APPLICANT: '�.�
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
07-00000283 Date
2/06/07
Property Address . . . . . .
4727 JOHNSON CREEK LOOP
Property ID:
660050-0301-0230
Application type description
TEMP POLE
Subdivision Name . . . . . .
WILLIAMS CREEK PH 3
Property Use . . . . . . . .
RESIDENTIAL
Property Zoning . . . . . . .
RURAL RESIDENTIAL SUB.
Application valuation
0
Owner
Contractor
------------------------
ACKLAM, SHAWN N & HALEY
------------------------
ACKLAM CONSTRUCTION,
INC.
1 FOREST DR
18932 SH 6 S
COLLEGE STATION TX 77840
COLLEGE STATION
TX 77845
(979) 690-8500
----------------------------------------------------------------------------
Permit . . . . . . TEMP POLE
PERMIT
Additional desc . . KW
Permit Fee . . . . 20.00
Issue Date . . . . 2/06/07
Valuation . . . .
0
----------------------------------------------------------------------------
Fee summary Charged
----------
Paid Credited
------------------------------
Due
-----------------
Permit Fee Total 20.00
20.00 .00
.00
Grand Total 20.00
20.00 .00
.00
- - - - - - - - - - - - - - - - - - - - - - ---------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
...
F Ofte Use ly
• 02rb2L0 7
1 APPLICATION FOR BUILDING PERMIT DATE: T CC REG �% r CITY OF COLLEGE STATION APPLICATION #
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840 TEMP POLE # 01- 25"D
CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX
Planning d DrUrlopmnu sera
W1NW.CSTX.GOV
ADDRESS/LOCATION: '4—I2-1 Joy\y► 3Sota GR4-PTcX. L-ooP
LOT Z3 BLOCK 1 t /SUBDIVISION W%UL_\L1l;NS CRTrXCJC_ SEC/PH
BUSINESS/OWNER NAME: S\AkWtiI Nr_y4_6. A PHONE: i32.0-X660
CONTRACTOR/HOMEOWNER: ACNw%_AjI,t CoNSp4.LJgDow1 PHONE: tAO -S500
CONTRACTOR ADDRESS: 1$`�32_ §a!M KwK 6 5ts s ,k
ELECTRICIAN: ' _LV_S!�7_%C. PLUMBER: AC.o r\V_c,k&"tCAA _
HVAC: l IN-�EL - A IQ. L`C GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ONLY
DUPLEX (Landscape P-ans REMODEL/RENOVATION* SWIMMING POOL
Required)
DESCRIPTION OF WORK: Nrc,W Hoe�1_
STRUCTURE USE:
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: ` F-S l"=,
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ Sao 000 TOTAL AREA: HEATED AREA: 4tai
a1/ (Cost of Labor and Materials)
PUBLIC SEWER NUMBER OF BEDROOMS:
SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS:�5
SEWER TAP: INTERIOR WALL TYPE: ZX'4
SIZE t_
WATER TAP: \�1e11�o0W EXTERIOR WALL TYPE: ZXt
O
SIZE w f` $_
U OTHER TAP: FOUNDATION TYPE:�T�ytZl�RaIDL LpwaC"T'iG
SIZE
TEMP POLE g-1-U ��0 co—� fee ROOF TYPE: GOt1Q �� SwtNI•�.S
�j GARAGE TYPE: 6 SINGLE DOUBLE TRIPLE
ATTACHED DETACHED CARPORT
�o
SIGNATURE OF APPLICANT:
*If proposed work involves new commercial construction or facade improvements/renovations to an existing
commercial property, building elevations are required.
Official Use Only
CQff ukents:
I ES o NO
Plans Examiner , pl'� S Zoning 0 icial — SD Lo�t`ows iw eoar�S
I �
c �� MIS �� 2►3.0 �
- Eny t N ee aj S I ab ,-r Pm k Lo ca,+sd. in/ per►. '
I Z I' C V LVeg;r 20V
Energy Code Compliance Information
% Glazing of exterior walls \
Insulation R value of exterior walls \°\
Insulation R value of ceiling I (flat areas) 3
Insulation R value of ceiling 2 (vaulted areas/no attic) 30
Glazing SHGC ,'32 -10/
Glazing U-Factor
R value of ductwork (o
A/C SEER Rating \b L/
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# 01 % DATE: _ 0
BUILDING ADDRESS: q Jjq Jo kdSov Cd,Pe4l L-oop
I. Foundation Requirements
NA/
A. Concrete minimum fc of 3000 PSI
B. Minimum four 4 inch slab thickness
C. Vapor barrier 6 mil. Poly min.
D. Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior unless over 60' Ion
3. Spacing of beams does not exceed 15'
E. Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F. Wood foundation details indicated
AVOK
II. Framing: Floor, Wall, Ceiling and Roof Requirements
VAOV
A. Girder or sill dimensions, grade & species
B. Floor joist size, spacing, grade & direction of span indicted on plans
C. Treated sill plate or bottom plate
D. Tenant separation in duplex
WOK
1. One -hour rated extending to roof deck
OK
E. Header sizes indicated on plans
F. Emergency bedroom egress
1. Exit direct to outside
2. O enable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G. O enable bathroom window required when mechanical ventilation is not provided
H. Stud grade andspacing
I. Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J. Roof framing Ian or elevation shown
K. Ceiling joist size, spacing, grade and direction of span indicated on plans
L. Attic access location and size indicated on plans
M. Span exceeding code tables must be engineered
N. Rafter size and spacing and purlin bracing indicated.
O. Roof covering used.
P. Indicate Wall Bracing Used for Lateral Bracing
k
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
II. Framing: Floor, Wall, Ceiling and Roof Requirements continued
NA/
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
S. 18" Overhang allowed on zero lot line construction, perforated soffit allowed.
T. Protected openings on walls < three feet from property line
VOK
Al A -
III. Stairway Requirements
N
A. Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" diff. max.
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1 /2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches above handrail
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
,
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located four or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four (4) inch sphere
IV. Fireplace Requirements (to be indicated onplans)
N
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must extend at least three (3) feet higher than the highest point where it
projects through the roof of a building & at least two (2) feet higher than any portion of the
building within ten (10) feet horizontal
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
V. Electrical Service Requirements
N K
A. Electrical plan to include:
1. Electrical fixtures & switches indicated .
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
VI. Plumbing Requirements
NAM
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
N
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N
Maximum drive width for residence is 25' combined for circular 12' minimum
Minimum 20 feet from driveway to side(intersecting) street
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
Approved subdivision
—NAAV
Plat filed
Flood lain Regulations — Ordinance 1301
N
Does not block any water course or divert any flow
Elevation certificate needed
K&OK
jz "__ � ✓ I _0 ,
PLANS EXAMINER DATE
"APPROVED PLANS PER IRC SECTION R106.3.1."