HomeMy WebLinkAboutRES2007-00282�-asa * Fans, Ki 3 1 PREPARED 4/02/08, 8:01:54 INSPECTION TICKET PAGE 1 City of ------------------------------------------------------------------------------------------------ College Station INSPECTOR: BUILDING INSPECTOR DATE 4/01/08 ADDRESS 4727 JOHNSON CREEK LOOP SUBDIV: WILLIAMS CREEK PH 3 CONTRACTOR ACKLAM CONSTRUCTION, INC. PHONE (979) 690-8500 OWNER ACKLAM, SHAWN N & HALEY PHONE PARCEL 660050-0301-0230 APPL NUMBER: 07-00000282 ------------------------------------------------------------------------------------------------ RESIDENTIAL, 1 UNIT DETACHED NEW PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B105 01 2/12/07 JGM BLDG, FOUNDATION -PIER TIME: 17:00 2/12/07 AP February 9, 2007 3:14:31 PM ncochran. B100 01 2/21/07 RH BLDG, FOUNDATION -SLAB TIME: 17:00 2/21/07 AP February 20, 2007 3:01:05 PM glsouth. 02/21/2007 11:49 AM. RH PDA Lower rear grade beams. Strings up on setbacks. Slab ground needed by final pour. B100 02 3/01/07 RH BLDG, FOUNDATION -SLAB TIME: 17:00 3/01/07 AP February 28, 2007 4:42:50 PM kwolfe. on beam inspection - pouring at 3:30 (fyi) early afternoon 03/01/2007 03:15 PM RH PDA Will be installing a grounding grid as per Shawn. B100 03 3/02/07 OC BLDG, FOUNDATION -SLAB TIME: 17:00 3/02/07 AP March 2, 2007 9:58:48 AM ncochran. 1st floor grade beams B100 04 4/04/07 JGM BLDG, FOUNDATION -SLAB TIME: 17:00 4/04/07 AP April 4, 2007 9:33:44 AM kwolfe. basement slab topping B120 01 6/14/07 JGM BLDG, FRAMING -PARTIAL TIME: 17:00 6/14/07 CA June 14, 2007 11:30:07 AM glsouth. SEE CHRIS BEFORE YOU GO OUT TO INSPECT. 06/14/2007 04:44 PM JGM PDA courtesy walk through B120 02 6/20/07 JGM BLDG, FRAMING -PARTIAL TIME: 17:00 6/20/07 AP June 19, 2007 12:25:12 PM acarter. EXTERIOR GARAGE AND BASEMENT WALLS 06/20/2007 12:12 PM JGM PDA exterior for brick, upper garage and basement areas B120 03 6/22/07 JGM BLDG, FRAMING -PARTIAL TIME: 17:00 6/22/07 AP June 22, 2007 8:21:54 AM acarter. LEFT EXT. MASTER BATH & MASTER BED 06/22/2007 04:20 PM JGM PDA exterior sheathing for brick, west -wall around master bath B120 04 7/03/07 OC BLDG, FRAMING -PARTIAL TIME: 17:00 7/03/07 AP July 2, 2007 12:56:15 PM acarter. EXTERIOR WALLS B115 01 10/12/07 JGM BLDG, FRAMING TIME: 17:00 10/12/07 AP September 19, 2007 2:07:00 PM acarter. AFTERNOON B120 05 10/12/07 JGM BLDG, FRAMING -PARTIAL TIME: 17:00 10/16/07 AP October 12, 2007 1:22:10 PM glsouth. PARTIAL FOR BASEMENT & GARAGE B120 06 10/17/07 JGM BLDG, FRAMING -PARTIAL TIME: 17:00 10/17/07 AP October 16, 2007 2:20:08 PM acarter. B130 01 10/29/07 OC BLDG, INSULATION TIME: 17:00 10/29/07 AP October 29, 2007 10:37:27 AM acarter. B125 01 4 01/08 n BLDG, FINAL TIME: 17:00 April 1, 2008 3:26:37 PM kwolfe. -------------------------------------- COMMENTS AND NOTES --------- -- V w Date: 4/2/2008 [nspection Comments for Final, Permit Year: 7 permit Number: 282 Address: 4727 JOHNSON CREEK LOOP Type Inspection Type Code Description Ins Status Inspection Result Comments B100 BLDG, FOUNDATION-SL, IC 02/21/2007 11:49 AM RH PDA B100 BLDG, FOUNDATION-SL, IC Lower rear grade beams. Strings up on setbacks. Slab B100 BLDG, FOUNDATION-SLi IC ground needed by final pour. B100 BLDG, FOUNDATION-SLi IC 03/01/2007 03:15 PM RH PDA B100 BLDG, FOUNDATION-SV IC Will be installing a grounding grid as per Shawn. B120 BLDG, FRAMING-PARTIF IC 06/14/2007 04:44 PM JGM PDA B120 BLDG, FRAMING-PARTIP IC courtesy walk through B120 BLDG, FRAMING-PARTIF IC 06/20/2007 12:12 PM JGM PDA B120 BLDG, FRAMING-PARTIP IC exterior for brick, upper garage and basement areas B120 BLDG, FRAMING-PARTIP IC 06/22/2007 04:20 PM JGM PDA B120 BLDG, FRAMING-PARTIP IC exterior sheathing for brick, west wall around master bath E150 ELEC, FINAL IC March 25, 2008 12:43:46 PM kwolfe. E150 ELEC, FINAL IC btu - on and running M110 MECH, FINAL IC March 25, 2008 12:44:05 PM kwolfe. M110 MECH, FINAL IC need proper access to upper furnance in attic and proper M110 MECH, FINAL IC combustion air for laundry room by final. M110 MECH, FINAL IC Space between door and concrete will count for M110 MECH, FINAL IC air requirements at bottom. M110 MECH, FINAL IC Ladder will be built for upper unit. P100 PLBG, ROUGH IN IC June 19, 2007 8:54:42 AM acarter. PLBG, FINAL IC March 25, 2008 12:43:14 PM kwolfe. IP125 P1251PLBG, FINAL I IC Ineed combustion air for laundry room by final Page 1 Amber Carter - Re. Calhng_for C O. @ 4727 Johnson Creek Page 1 From: Paul Schoenfeld To: Amber Carter; Benjamin McCarty; Chris Haver; ... Date: 4/3/2008 7:48 am Subject: Re: Calling for C.O. @ 4727 Johnson Creek ALL OK. PAUL >>> Gina Southerland 4/2/2008 8:15 AM >>> BP# 07-282 Gina Southerland CSR - Planning & Development Services City of College Station 979-764-3570 www.csbc.gov t U.S. DEPARTMENT OF HOMELAND SECURITY ELEVATION CERTIFICATE OMB No. 1660-0008 Federal Emergency Management Agency I Exoires February 28. 2009 National Flood Insurance Program Important: Read the instructions on pages 1-8. SECTION A - PROPERTY INFORMATION For Insurance Company Use: Al. Building Owner's Name Shawn & Haley Acklam Policy Number A2. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. I Company NAIC Number I 4727 Johnson Creek Loop City College Station State TX ZIP Code 77845 A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.) Lot 23, Block 1, Williams Creek Subdivision, Phase 3, Vol. 7249, Pg. 292 A4. Building Use (e.g., Residential, Non -Residential, Addition, Accessory, etc.) Residential A5. Latitude/Longitude: Lat. 30-34-45 N Long. 96-13-00 W Horizontal Datum: ❑ NAD 1927 ® NAD 1983 A6. Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance. A7. Building Diagram Number 7 A8. For a building with a crawl space or enclosure(s), provide A9. For a building with an attached garage, provide: a) Square footage of crawl space or enclosure(s) 1595 sq ft a) Square footage of attached garage 965 sq ft b) No. of permanent flood openings in the crawl space or b) No. of permanent flood openings in the attached garage enclosure(s) walls within 1.0 foot above adjacent grade 0 walls within 1.0 foot above adjacent grade 0 c) Total net area of flood openings in A8.b 0 sq in c) Total net area of flood openings in A9.b 0 sq in SECTION B - FLOOD INSURANCE RATE MAP (FIRM) INFORMATION B1. NFIP Community Name & Community Number B2. County Name B3. State City of College Station 480083 1 Brazos I TX B4. Map/Panel Number B5. Suffix B6. FIRM Index B7. FIRM Panel B8. Flood B9. Base Flood Elevation(s) (Zone Date Effective/Revised Date Zone(s) AO, use base flood depth) 48041CO205 C 205 C July 02, 1992 July 02, 1992 AE 212 B10. Indicate the source of the Base Flood Elevation (BFE) data or base flood depth entered in Item B9. ❑ FIS Profile ® FIRM ❑ Community Determined ❑ Other (Describe) B11. Indicate elevation datum used for BFE in Item 139: ® NGVD 1929 ❑ NAVD 1988 ❑ Other (Describe) B12. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? ❑Yes ®No Designation Date ❑ CBRS ❑ OPA SECTION C - BUILDING ELEVATION INFORMATION (SURVEY REQUIRED) Cl. Building elevations are based on: ❑ Construction Drawings* ❑ Building Under Construction* ® Finished Construction *A new Elevation Certificate will be required when construction of the building is complete. C2. Elevations - Zones Al-A30, AE, AH, A (with BFE), VE, V1-V30, V (with BFE), AR, AR/A, AR/AE, AR/A1-A30, AR/AH, AR/AO. Complete Items C2.a-g below according to the building diagram specified in Item A7. Benchmark Utilized N/A Vertical Datum NAVD88 - Geoid - GPS Conversion/Comments In this area of Texas, (Latitued-30 deg. Longitude-96 deg) difference in datum is negligible (<0.05') Check the measurement used. a) Top of bottom floor (including basement, crawl space, or enclosure floor)_ b) Top of the next higher floor c) Bottom of the lowest horizontal structural member (V Zones only) d) Attached garage (top of slab) e) Lowest elevation of machinery or equipment servicing the building (Describe type of equipment in Comments) f) Lowest adjacent (finished) grade (LAG) g) Highest adjacent (finished) grade (HAG) 220.48 ® feet ❑ meters (Puerto Rico only) 225.06 ® feet ❑ meters (Puerto Rico only) ❑ feet ❑ meters (Puerto Rico only) 235.50 ® feet ❑ meters (Puerto Rico only) 223.92 ® feet ❑ meters (Puerto Rico only) 223.89 ® feet ❑ meters (Puerto Rico only) 234.43 Z feet ❑ meters (Puerto Rico only) SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation information. 1 certify that the information on this Certificate represents my best efforts to interpret the data available. / understand that any false statement may be punishable by fine or imprisonment under 18 U.S. Code, Section 1001. ® Check here if comments are provided on back of form. Certifier's Name S.M. Kling, RPLS License Number 2003 Land Surveyor Company ng Address 4101 S. Texas Ave. Suite A City Bryan State TX ZIP Code 77802 FEMA Form 81-31, Febru_apf✓1006 See reverse side for continuation. Replaces all previous editions IMPORTANT: In these spaces, copy the corresponding information from Section A. For Insurance Company Use: Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number 4727 Johnson Creek Loop City College Station State TX ZIP Code 77845 Company NAIC Number SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION (CONTINUED) Copy both sides of this Elevation Certificate for (1) community official, (2) insurance agent/company, and (3) building owner. Comments tem A9.a-Attached Garage square footage - multiple garage space; square footage is for largest garage (3 car garage) Item C2.a-Elevation of basement at sump/crawl space. Item C2.b-Elevation of basement - Elevation of next higest floor = 235.52 Item C2.e-Elevation of Equipment - multiple a/c units; elevation is for lowest a/c pad Signature Date ❑ Check here if attachments SECTION E - BUILDING ELEVATION INFORMATION (SURVEY NOT REQUIRED) FOR ZONE AO AND ZONE A (WITHOUT BFE) For Zones AO and A (without BFE), complete Items El-E5. If the Certificate is intended to support a LOMA or LOMR-F request, complete Sections A, B, and C. For Items E1-E4, use natural grade, if available. Check the measurement used. In Puerto Rico only, enter meters. E1. Provide elevation information for the following and check the appropriate boxes to show whether the elevation is above or below the highest adjacent grade (HAG) and the lowest adjacent grade (LAG). a) Top of bottom floor (including basement, crawl space, or enclosure) is ❑ feet ❑ meters ❑ above or ❑ below the HAG. b) Top of bottom floor (including basement, crawl space, or enclosure) is ❑ feet ❑ meters ❑ above or ❑ below the LAG. E2. For Building Diagrams 6-8 with permanent flood openings provided in Section A Items 8 and/or 9 (see page 8 of Instructions), the next higher floor (elevation C2.b in the diagrams) of the building is ❑ feet ❑ meters ❑ above or ❑ below the HAG. E3. Attached garage (top of slab) is ❑ feet ❑ meters ❑ above or ❑ below the HAG. E4. Top of platform of machinery and/or equipment servicing the building is ❑ feet ❑ meters ❑ above or ❑ below the HAG. E5. Zone AO only: If no flood depth number is available, is the top of the bottom floor elevated in accordance with the community's floodplain management ordinance? ❑ Yes ❑ No ❑ Unknown. The local official must certify this information in Section G. SECTION F - PROPERTY OWNER (OR OWNER'S REPRESENTATIVE) CERTIFICATION The property owner or owner's authorized representative who completes Sections A, B, and E for Zone A (without a FEMA-issued or community -issued BFE) or Zone AO must sign here. The statements in Sections A, B, and E are correct to the best of my knowledge. Property Owner's or Owner's Authorized Representative's Name Shawn Acklam Address 4727 Johnson Creek Loop City College Station State TX ZIP Code 77845 Signature Date Telephone Comments ❑ Check here if attachments SECTION G - COMMUNITY INFORMATION (OPTIONAL) The local official who is authorized by law or ordinance to administer the community's floodplain management ordinance can complete Sections A, B, C (or E), and G of this Elevation Certificate. Complete the applicable item(s) and sign below. Check the measurement used in Items G8. and G9. G1. ❑ The information in Section C was taken from other documentation that has been signed and sealed by a licensed surveyor, engineer, or architect who is authorized by law to certify elevation information. (Indicate the source and date of the elevation data in the Comments area below.) G2. ❑ A community official completed Section E for a building located in Zone A (without a FEMA-issued or community -issued BFE) or Zone AO. G3. ❑ The following information (Items G4.-G9.) is provided for community floodplain management purposes. G4. Permit Number G5. Date Permit Issued G6. Date Certificate Of Compliance/Occupancy Issued G7. This permit has been issued for: ❑ New Construction ❑ Substantial Improvement G8. Elevation of as -built lowest floor (including basement) of the building: _❑ feet ❑ meters (PR) Datum G9. BFE or (in Zone AO) depth of flooding at the building site: ❑ feet ❑ meters (PR) Datum Local Official's Name Title Community Name Telephone Signature Date Comments ❑ Check here if attachments FEMA Form 81-31, February 2006 Replaces all previous editions Building Photographs See Instructions for Item A6. For Insurance Company Use: Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number 4727 Johnson Creek Loop City College Station State Tx ZIP Code 77845 Company NAIC Number If using the Elevation Certificate to obtain NFIP flood insurance, affix at least two building photographs below according to the instructions for Item A6. Identify all photographs with: date taken; "Front View" and "Rear View"; and, if required, "Right Side View" and "Left Side View." If submitting more photographs than will fit on this page, use the Continuation Page, following. Front View —Taken 12-20-07: Rear View —Taken 12-20-07: f r Building Photographs Continuation Page For Insurance Company Use: Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number 4727 Johnson Creek Loop City College Station State Tx ZIP Code 77845 Company NAIC Number If submitting more photographs than will fit on the preceding page, affix the additional photographs below. Identify all photographs with: date taken; "Front View" and "Rear View"; and, if required, "Right Side View" and "Left Side View." Riaht Side View — Taken 12-20-07 Left Side and FrontView— Taken 12-20-07 r - A*6k College Station Fire Department to= INSPECTIONITEST REQUEST `i'7 ,� Se nSon Cc-eek LooP Location of Inspection/Test:- � �` 17 -7 yS C,plle •02 �X Business/Job Phone: O rt '�) 6 9 0 - 0, Applicant Name: �a� r�cc� /��A�amo��;c'r�_ ����>, �r/°seS ._ 1�IC - Address: J1 Icz- tog Co11 ea'p 5 c I X 9 0 q a. Phone: Lg rr.gi wt o - 03O; Date of Application: _ 9 - // - o 7 INSPECTION/TEST FEE AMT. DUE Day Care Inspection......................................................................... $30.00 .......:..:....$ FosterHome Inspection................................................................... $30.00 .............. $ Nursing Home Inspection..:............................................................... $50.00 .............. $ Health Care Facility Inspection .............._,__.. _.............................. $50.00.............. $ . Fire Sprinkler/Standpipe Test, up to 100..................+�................ $50.00 .............. _ o $ O Each 100 thereafter, or fraction ..... # heads @ $5A.00/100 .............. $ Automatic Hood Fire Extinguisher Test ............................................ $30.00 .............. $ FuelTank Leak Test.:....................................................................... $50.00 .............. $ FuelLine Leak Test.......................................................................... $50.00 .............. $ Automatic Fire Alarm System Test, up to 25 initiating devices ......... $30.00 ............... $ Each 100 thereafter, orfraction ....# devices @ $50.00/100 .............. $ Natural Gas System Test.................................................................. $30.00 .............. $ Inspections Outside City Limits Standard Fee: x 1.5 = Vehicle Mileage: x 0.325 = Total Travel Time: x 20.00 = Total Inspection Fee: $ `� O TOTAL AMOUNT DUE: $ 5 �� 5 PLEASE NOTE: Re -tests and re -inspections will be billed at the same rate as the initial test or inspection. White: Applicant Yellow: Fire Marshal A.--- pink: Building -- CITY OFECOLLEGE NSTATION *** CUSTOMER RECEIPT *** Oper: KWOLFE Type: CT Drawer: I Date: 9/11/07 00 Receipt no: 381645 Quantity Amount Description FIRE SPRINKLER SYSTEM/001 F8 1.00 $50.00 STANDARDAUTOMATICFIRE TEST FIRE KW CK 1591 Tender detail 1591 $50.00 CK PERSONAL $50.00 Total tendered $50.00 Total payment Trans date: 9/11/07 Time: 10*10:40 THANK YOU U.S. DEPARTMENT OF HOMELAND SECURITY ELEVATION CERTIFICATE OMB No. 1660-0008 Federla 6pergtq Management Agency ExDires February 28. 2009 National Flood Insurance Program Important: Read the instructions on pages 1-8. SECTION A - PROPERTY INFORMATION for Insurance Company Use Al Building Owner's Name Shawn & Haley Acklam Policy Number A2. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Company NAIC Number 4727 Johnson Creek Loop City College Station State TX ZIP Code 77845 A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.) Lot 23, Block 1, Williams Creek Subdivision Phase 3 A4. Building Use (e.g., Residential, Non -Residential, Addition, Accessory, etc.) Residential A5. Latitude/Longitude: Lat. 30-34-45 N Long. 96-13-00 W Horizontal Datum: ❑ NAD 1927 ® NAD 1983 A6. Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance. AT Building Diagram Number 7 A8. For a building with a crawl space or enclosure(s), provide A9. For a building with an attached garage, provide: a) Square footage of crawl space or enclosure(s) 1595 sq ft a) Square footage of attached garage 965 sq ft b) No. of permanent flood openings in the crawl space or b) No. of permanent flood openings in the attached garage enclosure(s) walls within 1.0 foot above adjacent grade 0 walls within 1.0 foot above adjacent grade 0 c) Total net area of flood openings in A8.b 0 sq in c) Total net area of flood openings in A9.b 0 sa in btc I ION 13 - FLOOD INSURANCE RATE MAP (FIRM) INFORMATION B1. NFIP Community Name & Community Number B2. County Name B3. State City of College Station 480083 Brazos TX B4. Map/Panel Number 65. Suffix B6. FIRM Index B7. FIRM Panel B8. Flood B9. Base Flood Elevation(s) (Zone 48041CO205 C 205 C Date July 02, 1992 Effective/Revised Date July 02, Zone(s) AO, use base flood depth) 1992 AE 212 Gin L.d•....a.. 16 Me SGUrCe Oi Me Base rood mievation (BFE) data or base Hood depth entered in Item B9. ❑ FIS Profile ® FIRM ❑ Community Determined ❑ Other (Describe) Bl 1. Indicate elevation datum used for BFE in Item 69: ® NGVD 1929 ❑ NAVD 1988 ❑ Other (Describe) B12. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? ❑Yes ®No Designation Date ❑ CBRS ❑ OPA btc:I IUN c - BUILDING ELEVATION INFORMATION (SURVEY REQUIRED) Cl. Building elevations are based on: I@ Construction Drawings' ❑ Building Under Construction' ❑ Finished Construction 'A new Elevation Certificate will be required when construction of the building is complete. C2. Elevations -Zones Al-A30, AE, AH, A (with BFE), VE, V1-V30, V (with BFE), AR, AR/A, AR/AE, AR/A1-A30, AR/AH, AR/AO. Complete Items C2.a-g below according to the building diagram specified in Item AT Benchmark Utilized N/A Vertical Datum NAVD88 - Geoid - GPS Conversion/Comments In this area of Texas. (Latitued-30 deg Longitude-96 deg) difference in datum is negligible (<0 05') Check the measurement used. a) Top of bottom floor (including basement, crawl space, or enclosure floor)_ b) Top of the next higher floor c) Bottom of the lowest horizontal structural member (V Zones only) d) Attached garage (top of slab) e) Lowest elevation of machinery or equipment servicing the building (Describe type of equipment in Comments) f) Lowest adjacent (finished) grade (LAG) g) Highest adjacent (finished) grade (HAG) 224.7 ® feet ❑ meters (Puerto Rico only) 235.5 ® feet ❑ meters (Puerto Rico only) _ ❑ feet ❑ meters (Puerto Rico only) 235.5 ❑ feet ❑ meters (Puerto Rico only) 234.0 ❑ feet ❑ meters (Puerto Rico only) 234.0 ❑ feet ❑ meters (Puerto Rico only) 236.0 ❑ feet ❑ meters (Puerto Rico only) SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation information. l certify that the information on this Certificate represents my best efforts to interpret the data available. l understand that any false statement may be punishable by fine or imprisonment under 18 U. S. Code, Section 1001. ❑ Check here if comments are provided on back of forth. Certifier's Name S.M. Kling, RPLS License Number 2003 Title Registered Professional Land Surveyor Company Name Kling Engineering & Surveying rcivar% roan o i-J i, reDruary LUub See reverse side for continuation. 9 Replaces all previous editions IMPORTANT: In these spaces, copy the corresponding information from Section A. For Insurance Company Use: Building Str' ee Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number 4727 Johnson Creek Loop City College Station State TX ZIP Code 77845 Company NAIC Number SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION (CONTINUED) Copy both sides of this Elevation Certificate for (1) community official, (2) insurance agent/company, and (3) building owner. Signature Date ❑ Check here if attachments SECTION E - BUILDING ELEVATION INFORMATION (SURVEY NOT REQUIRED) FOR ZONE AO AND ZONE A (WITHOUT BFE) For Zones AO and A (without BFE), complete Items El-E5. If the Certificate is intended to support a LOMA or LOMR-F request, complete Sections A, B, and C. For Items El-E4, use natural grade, if available. Check the measurement used. In Puerto Rico only, enter meters. E1. Provide elevation information for the following and check the appropriate boxes to show whether the elevation is above or below the highest adjacent grade (HAG) and the lowest adjacent grade (LAG). a) Top of bottom floor (including basement, crawl space, or enclosure) is ❑ feet ❑ meters ❑ above or ❑ below the HAG. b) Top of bottom floor (including basement, crawl space, or enclosure) is ❑ feet ❑ meters ❑ above or ❑ below the LAG. E2. For Building Diagrams 6-8 with permanent flood openings provided in Section A Items 8 and/or 9 (see page 8 of Instructions), the next higher floor (elevation C2.b in the diagrams) of the building is ❑ feet ❑ meters ❑ above or ❑ below the HAG. E3. Attached garage (top of slab) is ❑ feet ❑ meters ❑ above or ❑ below the HAG. E4. Top of platform of machinery and/or equipment servicing the building is ❑ feet ❑ meters ❑ above or ❑ below the HAG. E5. Zone AO only: If no flood depth number is available, is the top of the bottom floor elevated in accordance with the community's floodplain management ordinance? ❑ Yes ❑ No ❑ Unknown. The local official must certify this information in Section G. SECTION F - PROPERTY OWNER (OR OWNER'S REPRESENTATIVE) CERTIFICATION The property owner or owner's authorized representative who completes Sections A, B, and E for Zone A (without a FEMA-issued or community -issued BFE) or Zone AO must sign here. The statements in Sections A, B, and E are correct to the best of my knowledge. Property Owner's or Owner's Authorized Representative's Name Shawn Acklam Address 1 Forest Drive City College Station State TX ZIP Code 77840 Signature Date Z1 -/07 Telephone9,9 -lbZ-o - \ 6bo Comments ❑ Check here if attachments SECTION G - COMMUNITY INFORMATION (OPTIONAL) The local official who is authorized and G of this Elevation Certificate. The information in Section C was taken from other documentation that has been signed and sealed by a licensed surveyor, engineer, or architect who is authorized by law to certify elevation information. (Indicate the source and date of the elevation data in the Comments area below.) A community official completed Section E for a building located in Zone A (without a FEMA-issued or community -issued BFE) or Zone AO. G1. ❑ G2. ❑ G3. ❑ or ordinance to administer the community's floodplain management oramance can compiew of ete the applicable item(s) and sign below. Check the measurement used in Items G8. and G9. The following information (Items G4.-G9.) is provided for community floodplain management purposes. G4. Permit Number G5. Date Permit Issued A, G6. Date Certificate Of Compliance/Occupancy Issued G7. This permit has been issued for: ❑ New Construction ❑ Substantial Improvement G8. Elevation of as -built lowest floor (including basement) of the building: _❑ feet ❑ meters (PR) Datum G9. BFE or (in Zone AO) depth of flooding at the building site: ❑ feet ❑ meters (PR) Datum Local Official's Name Title Community Name Telephone Date Signature Comments ❑ Check here if att7 Replaces all previ FEMA Form 81-31, February 2006 MAY.21.2007 4:04PM Brazos County Health Department NO-6407 P. 2 Brazos County Health Department 201 North Texas Ave. Bryan, TX 77803-5317 d (979)361-4440 LICENSE TO OPERATE AN ON SITE SEWAGE FACILITY THIS IS TO CERTIFY that the on site sewage facility owned by: OSSF #: 2007 - 2706 ACKLAM, SHAWN L JOHNSON CREEK LOOP 4727, College Station TX 77845 Grid: 01"ti WILLIAMS CREEK Block: Lot: Certificate of Compliance: IN CS. Installed By: GREENSAGE, JEFF Bedrooms: 2 Engineered By: GONZALEZ, STEVEN- PREMIER ENVIRONMENTAL DESIGNS Employees: 0 Date Purchased: 05/17/07 Final Inspection Date: 05/21/07 MaxGPD: 519 Disinfectant: Chlorine The private sewage facility licensed above was installed according to the current and minimum guidelines of the Texas Commission on Environmental Quality (TCEQ) and Brazos County. This aerobic system with spr�spersal requires a disinfectant for final treatment of the sprayed effluent. It is the responsibility of the homeowner to monitor the disinfectant and to add more when needed. (Swimming pool chlorine tablets are not acceptable substitutes). Under no circumstance are any food crops or edible foods.to be grown in Me spray area. Mowing of the sp:rayfield on a regular basis should also be done to help with the evaporation process. The current maintenance contract for this system will expire 2-years from the above final inspection date. A new maintenance contract must be in force at that time, and a copy of the new contract filed with this office 30 days before contract expires. This is a NON -TRANSFERABLE license. Upon transfer of ownership, the new owner shall be required to transfer the original license into his/her name_ Should the system malfunction in the future, it will be the licensee's responsibility to bring the system in compliance with all current state and county regulations. This license does not extend to the material's, workmanship, or fabrication, of the system, so as to expressly or impliedly grant the owner, or installer of the system any warranty by / or rights against Brazos County and / or the Brazos County Health Department, as to the quality or durability of the system, nor compliance with licensee's individual specifications and requirements, but solely relates to the system meeting the requirements of the.above named regulatory body in effect as of this date.. SPRAY AREA MUST BE CLEARED OF YAUPON AND SODDED OR SEEDED WITH GRASS. SPRAYFIELD SHOULD BE MOWED AS NECESSARY TO MAINTAIN OPTIMUM CONDITIONS. "�'�, �aSo��s 7Co7 R-10 Environmental Health Specialist BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979) 764-3�576 FAX: (979) 764-3496 ---------------------------------------------------------------------------- Application Number- 07-00000282 Date 2/06/07 Property Address . . . . . . 4727 JOHNSON CREEK LOOP Property ID: 660050-0301-0230 R #: R303818 Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . WILLIAMS CREEK PH 3 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . RURAL RESIDENTIAL SUB. Application valuation . . . . 300000 Owner Contractor ------------------------ ACKLAM, SHAWN N & HALEY ------------------------ ACKLAM CONSTRUCTION, INC. 1 FOREST DR 18932 SH 6 S COLLEGE STATION TX 77840 COLLEGE STATION TX 77845 (979) 690-8500 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE 2X6 IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 3.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 4187.00 INTERIOR WALL TYPE 2X4 NUMBER OF BATHROOMS 4.50 NUMBER OF BEDROOMS 4.00 SEWER TYPE SEPTIC TAZ 329.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . KW Permit Fee . . . . 1060.00 Plan Check Fee .00 Issue Date . . . . 2/06/07 Valuation . . . . 300000 Expiration Date . . 8/05/07 Qty Unit Charge Per Extension BASE FEE 460.00 200.00 3.0000 THOU BLDG, VAL 100001-500000 600.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTERS) PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 2211 ------------------------------------------------ ------ --- ----- -_------- BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE,STATION, TX 77840 PHONE: (979)764-357d FAX: (979)764-3496 Page 2 Application Number . . . . . 07-00000282 Date 2/06/07 ------------------------------------ 7--------------------------------------- Special Notes and Comments X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY OBTAIN HEALTH DEPARTMENT APPROVAL: CALL 979-361-4440 FOR MORE INFORMATION. THIS INCLUDES SEPTIC SYSTEMS INSTALLS. PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8" side & 16" front) For Openings >6 sq. ft. (12" side & 20" front) ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE BUILDING DEPT REPRESENTATIVE: APPLICANT: `� BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 3 Application Number . . . . . 07-00000282 Date 2/06/07 ---------------------------------------------------------------------------- Special Notes and Comments PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12' ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE For residential applications with a glazing area that exceeds 150 of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. ADD SMOKE DETECTOR(S) PER NOTES ON PLANS SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS ------------------------------------------------ ----- --- ---- BUILDING DEPT REPRESENTATIVE: • APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 07-00000282 Page 4 Date 2/06/07 Special Notes and Comments REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. STAIRS SHALL COMPLY WITH SECTION R-311 (2003 IRC) WITH A CONTINUOUS HANDRAIL OR SECTION 1009 (2003 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003 IRC) RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK Elevation Certificate Required MINIMIUM F.F. 213.0 12" Culvert Required. ENGINEERED PIERS, SLAB AND CMU BLOCK WALLS SEPTIC SYSTEM For all walls other than CMU block walls to be Fully Sheathed with OSB or Plywood. ELEVATION CERTIFICATE REQUIRED - PROVIDE ELEVATION CERTIFICATE PRIOR TO SLAB INSPECTION AND A SECOND CERTIFICATE PRIOR TO FINAL INSPECTION/C.O. Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total 1060.00 1060.00 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 1060.00 1060.00 .00 .00 -------------------------------- ------ - -- --------- BUILDING DEPT REPRESENTATIVE: 13 APPLICANT: '�.� TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 07-00000283 Date 2/06/07 Property Address . . . . . . 4727 JOHNSON CREEK LOOP Property ID: 660050-0301-0230 Application type description TEMP POLE Subdivision Name . . . . . . WILLIAMS CREEK PH 3 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . RURAL RESIDENTIAL SUB. Application valuation 0 Owner Contractor ------------------------ ACKLAM, SHAWN N & HALEY ------------------------ ACKLAM CONSTRUCTION, INC. 1 FOREST DR 18932 SH 6 S COLLEGE STATION TX 77840 COLLEGE STATION TX 77845 (979) 690-8500 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . KW Permit Fee . . . . 20.00 Issue Date . . . . 2/06/07 Valuation . . . . 0 ---------------------------------------------------------------------------- Fee summary Charged ---------- Paid Credited ------------------------------ Due ----------------- Permit Fee Total 20.00 20.00 .00 .00 Grand Total 20.00 20.00 .00 .00 - - - - - - - - - - - - - - - - - - - - - - --------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: ... F Ofte Use ly • 02rb2L0 7 1 APPLICATION FOR BUILDING PERMIT DATE: T CC REG �% r CITY OF COLLEGE STATION APPLICATION # 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 TEMP POLE # 01- 25"D CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX Planning d DrUrlopmnu sera W1NW.CSTX.GOV ADDRESS/LOCATION: '4—I2-1 Joy\y► 3Sota GR4-PTcX. L-ooP LOT Z3 BLOCK 1 t /SUBDIVISION W%UL_\L1l;NS CRTrXCJC_ SEC/PH BUSINESS/OWNER NAME: S\AkWtiI Nr_y4_6. A PHONE: i32.0-X660 CONTRACTOR/HOMEOWNER: ACNw%_AjI,t CoNSp4.LJgDow1 PHONE: tAO -S500 CONTRACTOR ADDRESS: 1$`�32_ §a!M KwK 6 5ts s ,k ELECTRICIAN: ' _LV_S!�7_%C. PLUMBER: AC.o r\V_c,k&"tCAA _ HVAC: l IN-�EL - A IQ. L`C GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ONLY DUPLEX (Landscape P-ans REMODEL/RENOVATION* SWIMMING POOL Required) DESCRIPTION OF WORK: Nrc,W Hoe�1_ STRUCTURE USE: HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: ` F-S l"=, TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ Sao 000 TOTAL AREA: HEATED AREA: 4tai a1/ (Cost of Labor and Materials) PUBLIC SEWER NUMBER OF BEDROOMS: SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS:�5 SEWER TAP: INTERIOR WALL TYPE: ZX'4 SIZE t_ WATER TAP: \�1e11�o0W EXTERIOR WALL TYPE: ZXt O SIZE w f` $_ U OTHER TAP: FOUNDATION TYPE:�T�ytZl�RaIDL LpwaC"T'iG SIZE TEMP POLE g-1-U ��0 co—� fee ROOF TYPE: GOt1Q �� SwtNI•�.S �j GARAGE TYPE: 6 SINGLE DOUBLE TRIPLE ATTACHED DETACHED CARPORT �o SIGNATURE OF APPLICANT: *If proposed work involves new commercial construction or facade improvements/renovations to an existing commercial property, building elevations are required. Official Use Only CQff ukents: I ES o NO Plans Examiner , pl'� S Zoning 0 icial — SD Lo�t`ows iw eoar�S I � c �� MIS �� 2►3.0 � - Eny t N ee aj S I ab ,-r Pm k Lo ca,+sd. in/ per►. ' I Z I' C V LVeg;r 20V Energy Code Compliance Information % Glazing of exterior walls \ Insulation R value of exterior walls \°\ Insulation R value of ceiling I (flat areas) 3 Insulation R value of ceiling 2 (vaulted areas/no attic) 30 Glazing SHGC ,'32 -10/ Glazing U-Factor R value of ductwork (o A/C SEER Rating \b L/ PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# 01 % DATE: _ 0 BUILDING ADDRESS: q Jjq Jo kdSov Cd,Pe4l L-oop I. Foundation Requirements NA/ A. Concrete minimum fc of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier 6 mil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior unless over 60' Ion 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated AVOK II. Framing: Floor, Wall, Ceiling and Roof Requirements VAOV A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex WOK 1. One -hour rated extending to roof deck OK E. Header sizes indicated on plans F. Emergency bedroom egress 1. Exit direct to outside 2. O enable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. O enable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Exterior wall covering indicated on plans 2. Sheathing indicated on plans 3. Moisture barrier indicated on plans J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size and spacing and purlin bracing indicated. O. Roof covering used. P. Indicate Wall Bracing Used for Lateral Bracing k PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX II. Framing: Floor, Wall, Ceiling and Roof Requirements continued NA/ P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations S. 18" Overhang allowed on zero lot line construction, perforated soffit allowed. T. Protected openings on walls < three feet from property line VOK Al A - III. Stairway Requirements N A. Stairway Details 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" diff. max. 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8 B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1 /2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches above handrail 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details , 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located four or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four (4) inch sphere IV. Fireplace Requirements (to be indicated onplans) N A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must extend at least three (3) feet higher than the highest point where it projects through the roof of a building & at least two (2) feet higher than any portion of the building within ten (10) feet horizontal PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX V. Electrical Service Requirements N K A. Electrical plan to include: 1. Electrical fixtures & switches indicated . 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location VI. Plumbing Requirements NAM A. Pressure reducing valve required when water pressure exceeds 80 psi B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) VIII. Energy Requirements N A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 N Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements N Maximum drive width for residence is 25' combined for circular 12' minimum Minimum 20 feet from driveway to side(intersecting) street Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 Approved subdivision —NAAV Plat filed Flood lain Regulations — Ordinance 1301 N Does not block any water course or divert any flow Elevation certificate needed K&OK jz "__ � ✓ I _0 , PLANS EXAMINER DATE "APPROVED PLANS PER IRC SECTION R106.3.1."