PREPARED 7/03/07, 8:00:29 INSPECTION TICKET PAGE 5
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 7/02/07
------------------------------------------------------------------------------------------------
ADDRESS . : 1621 MARINER'S CV SUBDIV: SOUTH HAMPTON PH 4
CONTRACTOR RIKE HOMES PHONE (979) 774-0165
OWNER . . PHONE
PARCEL . . 579020-0470-0130
APPL NUMBER: 06-00003693 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 2/19/07 RH BLDG, FOUNDATION -SLAB TIME: 17:00
2/19/07 AP February 19, 2007 8:02:05 AM kwolfe.
02/19/2007 04:10 PM RH PDA
February 19, 2007 4:53:44 PM ncochran.
FORM SURVEY SUBMITTED
B115 01 3/28/07 RH BLDG, FRAMING TIME: 17:00
3/28/07 AP March 28, 2007 10:08:39 AM kwolfe.
B130 01 4/12/07 TB BLDG, INSULATION TIME: 17:00
4/12/07 AE April 12, 2007 2:20:33 PM glsouth.
HOUSE WAS SHEETROCKED WITHOUT INSPECTION BEING DONE (SEE
INSULATION REPORT IN FOLDER)
B125 01 7/92///DD7 B��i� BLDG, FINAL TIME: 17:00
July 2, 2007 2:44:56 PM acarter.
------------------------------------- COMMENTS AND NOTES -----------
T_
v
WF0863842-4/.1661l City of College. Station PAGE 1
REQ. DATE: 01/05/07 01/05/07 16:23:33
LOCATION: 1621 MARINER'S CV LOC ID: 205984
REQUESTOR: RIKE HOMES ORIGIN: CUSTOMER -WALK IN
REQ. USER: NCOCHRAN AUTH. USER: NCOCHRAN WORK TYPE: ROUT
4" SWR TAP 3/4" WTR TAP
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 01/05/07 SCHED COMPLETION: 01/05/07
********************************************************************************
JOB ORDER RESULT COMMENTS
+/- 7- 9' FROM
SIDE OF HOUSE TO
PROPERTY LINE
75.00'
M�R1ME95 Co\/f�
HOUSE SITS 4- - 0.
BACK FROM FRONT
PROPERTY LINE.
SOUTH HAMPTON
PHASE 4
BLOCK 7, LOT 13
MARINER'S COVET
SITE PLAN
(7/3/2007) Gina Southerland Re Calling for C.O. @ 1621 Mariner's Cove W _Page 1
From: Mitchell Carson
To: Benjamin McCarty; Chris Haver; Gina Southerland; Joe Garcia; Kim Wol...
Date: 7/3/2007 12:33 PM
Subject: Re: Calling for C.O. @ 1621 Mariner's Cove
This one is ok Mitch
>>> Gina Southerland 67/03/07 8:17 AM >>>
BP# 06-3693
Gina Southerland
CSR - Planning & Development Services
City of College Station
979-764-3570
www.cstx.gov
APR-13-2007 01:41 AM P.01
:k
THERMO INS., ATION CO., INC.
College 54ation, Texas 77845 13
to 6, ry
Rv-,S, ?) AN �`� ,earn'► rve �
l�aa r
SO�A4 �
I � t
r u 6z. w J,� ry
ZbLefe's �NOCV A4 L� r3 ASS
Y\j Al
f
-�,ty-o re
uj. bA41 TYvE.
R CAN
eLi cfQk��,
(• rkAe- C�Q1J�rs�A 1..� � s
Ci� R} S �e A�IN S
vim� b
r
YJ3
)
r�- ) �)4,
Feb.19. 2007 5:40PM tom rike
No.0365 P. 2
S Amyl• w lsm
lbd ----- Ira— �
AW
I
Ar ur I
NI' 7YI
;I 4
g Forms
0 LW 14
La ,2
y, ,I,.
� rX
Ar
x
%%W` n�a aia•
[ „Y,• .m Red
N Old
fad SA'
Yoe Hal
Form Survey
1621 Mariner's Cove
Prepared For. Rike Homes
eeing all of Lot 13 (7N/WWV), Black 7 (SEVEN), StNflt/ M4MP7OM, PNASF FOUR on addl0on to
the a-& of Cadlega SYaffan, Swes Count; Terns, --ding M the pbt rocadad in Vatume
7659 Page 248 of the Of/lda/ Reco/da of Brazes Carry. Texas
6 Pau/ ggFjms, Repstemd Professional Land Surveyor Ah 5743 do hereby COWS, that ibis plat
Atwwants Me results of a surrey performed on Me ground under my suparvlsA- on January
20, 2007, and a true and correct to the hest of my knowledge.
/ further c"Yy that no kr<pmmmenta en bW9 property encroach on adjacent pmpm{y, nor do
any Aprovements on adjacent pmpery encroach an to Mrs property, accept as shown. This
propedy does not Ge wrYhin a Wdd FAwd Hazard Area oe depicted an Food /nsumnce Rote
Atop No. 4W41 0205D dated Fahmary 9, 2=
PAUL I WILL LWS
LAND I SURVEYING CO.
307 South Main Street Ste. 206
an, TX 77803
9 9-779-7670
Fox 979-779-7672
pwlandsurveying®eorthlink.net
Notes:
North odentahcn is hosed on rotating the
south line to plot cola in 780124B.
This surrey woe prepomd without the benel/t
or o Tide CommrYment
Ar:1 pw/sco `diants 17OLUdwg
WF0868367 / 001 City of College Station PAGE lJ
REQ. DATE: 01/24/07 01/24/07 16:46:44
LOCATION: 1621 MARINER'S CV LOC ID: 205984
REQUESTOR: RIKE HOMES ORIGIN: CUSTOMER -WALK IN
REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT
TEMP POLE PASSED
TASK:; SET UP NEW UTILITY ACCT SET READY
SCHED START: 01/24/07 SCHED COMPLETION: 01/24/01
JOB ORDER RESULT COMMENTS
• 1 ern
BUILDING PERMIT
4+' ` CITY OF COLLEGE STATION >'
1101 TEXAS AVEtii;
COLLEGE STATION, TX 77840�°
S .
�., PHONE: (979)764-3570 FAX: (979)764-3496
-----------------------------------------------------------------------------
Application Number . . . . .
Property Address . . . . . .
Property ID:
R #.
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
Owner
------------------------
06-00003693 Date 1/05/07
1621 MARINER'S CV
579020-0470-0130
R
RESIDENTIAL, 1 UNIT DETACHED NEW
SOUTH HAMPTON PH 4
RESIDENTIAL
SINGLE FAMILY RESIDENTIAL
286900
Contractor
------------------------
OWNER
--- Structure Information 000 000 SINGLE FAMILY
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info . . . . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
2684.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
3.50
NUMBER OF BEDROOMS
5.00
SEWER TYPE
PUBLIC
TAZ
444.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . . NC
Permit Fee . . . . 1021.00 Plan Check Fee
.00
Issue Date . . . . 1/05/07 Valuation . . .
. 286900
Expiration Date . . 7/04/07
Qty Unit Charge Per
Extension
BASE FEE
460.00
187.00 3.0000 THOU BLDG, VAL 100001-500000
561.00
------------------------------------------°----------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS OPENING (MINIMUM OUGH-FRAMED SIZE
22"
------------------------------------------- ------------------
006-0
BUILDING DEPT REPR VE:A"
APPLICANT:
BUILDING PERMIT i
r. CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 06-00003693
Page 2
Date 1/05/07
Special Notes and Comments
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
------------------------------------------- A------�--- '--t--------------
BUILDING DEPT REPRES
APPLICANT:
BUILDING PERMIT
o CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 3
Application Number . . . . . 06-00003693 Date 1/05/07
-----=----------------------------------------------------------------------
Special Notes and Comments
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITH N 24" OF DOORS IN
----------
--------------------------------------------- ------ --
BUILDING DEPT REPRZ'S�TAtIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page
4
Application Number . . . . . 06-00003693 Date
1/05/07
----------------------------------------------------------------------------
Special Notes and Comments
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES
Narrow Wall Bracing Fully Sheathed with Interior Anchors and
Bracing at front door area and Simpson Panel at back door
area.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due .
----------------------------------------
-----------------
Permit Fee Total 1021.00 1021.00 .00
.00
Plan Check Total .00 .00 .00
.00
Other Fee Total 750.00 750.00 .00
.00
Grand Total 1771.00 1771.00 .00
.00
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - i - - - - - - - - -
BUILDING DEPT REP5T�VE-
=KNMM�_r
APPLICANT:
TEMPORARY POLE PERMIT . ►
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE, STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
Property Address . . . . . .
Property ID:
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation
Owner
------------------------
06-00003695 Date 1/05/07
1621 MARINER'S CV
579020-0470-0130
TEMP POLE
SOUTH HAMPTON PH 4
RESIDENTIAL
SINGLE FAMILY RESIDENTIAL
0
Contractor
------------------------
OWNER
Structure Information 000 000
Construction Type
. . . . .. COMBUSTIBLE (UNPROTECTED)
Occupancy Type .
. . . . . RESIDENTIAL-SFR/DUPLEX
----------------------------------------------------------------------------
Permit . . . . .
. TEMP POLE PERMIT
Additional desc ...
NC
Permit Fee . . .
. 20.00
Issue Date . . .
. 1/05/07 Valuation . . .
. 0
----------------------------------------------------------------------------
Other Fees . . .
. . . . . . TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
F.ee summary
Charged Paid Credited
----------------------------------------
Due
-----------------
Permit Fee Total
20.00 20.00 .00
.00
Other Fee Total
45.00 45.00 .00
.00
Grand Total
65.00 65.00 .00
.00
------------
------------------------------------------------ --- ---
BUILDING DEPT R 5 TIVE:
APPLICANT:
J'
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
W W W.CI.COLLEGE-STATION.TX. US
A , For Offm use only
DATE:
APPLICATIONS IVY? �✓�� V
TEMP POLE #
.ADDRESS/LOCATION: 1621 Mariner's Cove /
LOT 13 /--BLOCK 7 ;KBDIVISION SOUTH HAMPTON - PHASE 4
BUSINESS/OWNER NAME: RIKE HOMES, LLC. PHONE: 774-0165
CONTRACTOR/HOMEOWNER: Tom Rike PHONE: 224-4616
CONTACTOR ADDRESS: 2210 E. Briargate
ELECTRICIAN: Mathew's Electric PLUMBER: Bass Plumbing
HVAC: Control Temp GOOD CENTS (Residential only): No
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans Req) REMODEURENOVATION SWIMMING POOL
DESCRIPTION OF WORK: Conventional Framing
STRUCTURE USE: Single Family Residence
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ N/A f�
VALUATION: $286,900 TOTAL AREA:_3368 HEATED AREA:2684 .1�1 :
(Cost of La or and Materials)
FX PUBLIC SEWER NUMBER OF BEDROOMS: 5
SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: 35
wV
z
m
m
0
co
QX SEWER TAP: 4" INTERIOR WALL TYPE: Sheet Rock O
SIZE 30
WATER TAP: %" EXTERIOR WALL TYPE:
SIZE
❑ OTHER TAP: FOUNDATION TYPE:
SIZE
EMR,,jPOLE ROOF TYPE:
LwE TYPE: SINGLE DOUBLE
ATTACHED X_ DETACHED
SI TURE OF APPLICANT: —�
Plans Examiner
Use Only
TRIPLE
_,Zoning Official
Doe -A,
Siding/Masonry/Stone
Slab on Grade
Composition
C ments:
as),r NO
i
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
R13
Insulation R value of ceiling 1 (flat areas)
R30
Insulation R value of ceiling 2 (vaulted areas/no attic)
R19 /
Glazing SHGC
.40
Glazing U-Factor
.65
R value of ductwork
R6 /
A/C SEER rating
12
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# b ( _ -?( 93
DATE: /Z-- I --D
BUILDING ADDRESS:
Ra ZI Mftr�je2-s Cavz.
I. Foundation Requirements
N K
A.
Concrete minimum f'c of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier 6 mil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior unless over 60' Ion
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F.
Wood foundation details indicated
WA0K
II. Framing: Floor, Wall, Ceiling and Roof Requirements
N
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
K
1. One -hour rated extending to roof deck
#qAJOK
E.
Header sizes indicated on plans
F.
Emergency bedroom egress
1. Exit direct to outside
2. O enable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
O enable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
N.
O.
P.
Span exceeding code tables must be engineered
Rafter size and spacing and purlin bracing indicated.
Roof covering used.
Indicate Wall Bracing Used for Lateral Bracing
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
II. Framing: Floor, Wall, Ceiling and Roof Requirements continued
NAAKI
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
S. 18" Overhang allowed on zero lot line construction, perforated soffit allowed.
T. Protected openings on walls < three feet from property line
OK
III. Stairway Requirements
OK
A. Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" diff. max.
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches above handrail
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located four or more risers above floor/ rade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four (4) inch sphere
IV. Fireplace Requirements to be indicated onplans)A/
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must extend at least three (3) feet higher than the highest point where it
projects through the roof of a building & at least two (2) feet higher than any portion of the
building within ten (10) feet horizontal
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
V. Electrical Service Requirements
N
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
VI. Plumbing Requirements
N K
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
NAJOK
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N OK
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N K
Maximum drive width for residence is 25' combined for circular 12' minimum
Minimum 20 feet from driveway to side(intersecting) street
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
N K
Does not block any water course or divert any flow
Elevation certificate needed
K
Permit Number
REScheck Compliance Certificate Checked By/Date
2003 IECC
REScheck So$ware Version 3.6 Release 2
Data filename: C:\Program Files\ART Inc\Chief Architect 10.0 Full Version\BUSINESS
FILES\RIKE\LOT 13 MARINERSCOVE.RCK
PROJECT TITLE: LOT 13
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
WINDOW / WALL RATIO: 0.15
DATE: 10/26/06
DATE OF PLANS: OCTOBER 2006
PROJECT DESCRIPTION:
SOUTH HAMPTON
MARINER'S COVE
DESIGNER/CONTRACTOR:
DESIGNS IN RESIDENCE - DOROTHY ROSE
TOM RIKE, RIKE HOMES
COMPLIANCE: Passes
Maximum UA = 744
Your Home UA = 489
34.3% Better Than Code (UA)
Maximum SHGC = 0.40
Your SHGC = 0.40
Ceiling 1: Flat Ceiling or Scissor Truss
Wall 1: Wood Frame, 16" o.c.
Window 1:
Metal Frame with Thermal Break:Double Pane with Low-E
SHGC: 0.40
Door 3: Solid
Door 5: Glass
SHGC: 0.40
Heat Pump 1: Air Source, 6.8 HSPF, 13 SEER
Air Conditioner 1: Electric Central Air, 13 SEER
Gross Glazing
Area or Cavity Cont. or Door
Perimeter R-Value R-Value U-Factor UA
2734 30.0
30.0 46
2786 13.0
3.6 162
383
0.650 249
24
0.650 16
24
0.650 16
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans,
specifications, and other calculations submitted with the permit application. The proposed building has been designed to
meet the 2003 IECC requirements in REScheck Version 3.6 Release 2 (formerly MECcheck) and to comply with the
mandatory requirements listed in the REScheck Inspection Checklist.
Builder/Designer Date