Loading...
HomeMy WebLinkAboutRES2006-03669, 06-3670�_ - ,... _ �_ _ _.. ,��- -. y1 , L / � � _ � _ I « b ..r I9 25015, �a„ E„r 47.00 N 20 Y� U . Q Im Lu W N Lu co o co ? n 3 v -4 I r+ I 1-4 I m �Iz I I I I 7 M -7 9 - 31 _ L . Milt W I cr � �o� .Puy � w w c o " I N 0 n WN m Ki rn t in e Lo z ; I 2709 HORSE HAVEN LANE .,►;:: �� CQ LOT: 5 BLOCK* 1 14'-1 " L�,NE HORSE HAVEN SECTION: 2 HORSEHAVEN ESTATES COLLEGE STATION, TEXAS BUILDER: OAKWOOD CUSTOM HOMES GROUP LTD SITE PLAN SCALE: 1 = 2 0' G:\OAILDWG\HORSE HAVEN\HMS-2709-steetdusl\HH5-2709HHL-steeidus_remer.dwg, Model, 12/07/200609:50:23 AM, Administrator, MSHMA-LEGAL.pd, Legal, 1:240 11 { (9/20/2007) Gina Southerland Re: Calling for CO @ 2709 Horse Haven Ln Page 1 ' a W From: Paul Schoenfeld To: Amber Carter; Benjamin McCarty; Chris Haver; Gina Southerland; Joe G... Date: 9/20/2007 9:03 AM Subject: Re: Calling for CO @ 2709 Horse Haven Ln ALL OK. PAUL >>> Kim Wolfe 09/19/07 8:11 AM >>> any issues? BP # 06-3669 Thanks Kimberly Wolfe, CPS/CAP City of College Station Planning & Development Services (979)764-3570 www.cstx.gov dl PREPARED 9/19/07, 7:52:13 INSPECTION TICKET PAGE 2 City of ------------------------------------------------------------------------------------------------ College Station INSPECTOR: BUILDING INSPECTOR DATE 9/18/07 ADDRESS . : 2709 HORSE HAVEN LN SUBDIV: CONTRACTOR OAKWOOD CUSTOM HOMES PHONE (979) 690-1504 OWNER PHONE PARCEL 336300-0201-0050 APPL NUMBER: 06-00003669 ------------------------------------------------------------------------------------------------ RESIDENTIAL, 1 UNIT DETACHED NEW PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 1/10/07 RH BLDG, FOUNDATION -SLAB TIME: 17:00 1/10/07 AP January 10, 2007 10:00:13 AM ncochran. O1/10/2007 05:22 PM RH PDA Strings up, slab ground installed. B115 01 2/08/07 JGM BLDG, FRAMING TIME: 17:00 2/08/07 AP February 8, 2007 8:35:49 AM kwolfe. B130 01 2/13/07 OC BLDG, INSULATION TIME: 17:00 2/13/07 AP February 12, 2007 2:44:22 PM kwolfe. B1125 01 8/07/07 JGM BLDG, FINAL TIME: 17:00 i 8/08/07 CA August 7, 2007 12:25:38 PM acarter. 11 August 8, 2007 8:47:13 AM glsouth. 08/08/2007 10:03 AM JGM PDA cancelled per johnny not ready B125 02 8/22/07 RH BLDG, FINAL TIME: 17:00 8/22/07 DP August 22, 2007 10:47:39 AM acarter. 08/22/2007 04:41 PM RH PDA Install all hardware. Exposed electrical box in garage. Cover walkway area at platform to furnace to prevent damage and stepping through ceiling. B125 03 9/13/07 BI BLDG, FINAL TIME: 17:00 9/14/07 CA September 13, 2007 2:13:31 PM glsouth. B125 04 9/18/07 BI BLDG, FINAL TIME: 17:00 September 18, 2007 3:11:18 PM glsouth. -------------------------------------- COMMENTS AND NOTES -------------------------------------- Date: 9/14/2007 Inspection Comments for Finals Permit Year: 6 Permit Number: 3669 Address: 2709 HORSE HAVEN LN Type Inspection Type Code Description si ins Inspection Result Comments B100 BLDG, FOUNDATION -SLAB IC 01/10/2007 05:22 PM RH PDA B100 BLDG, FOUNDATION -SLAB IC Strings up, slab ground installed. B125 BLDG, FINAL IC 08/08/2007 10:03 AM JGM PDA B125 BLDG, FINAL IC cancelled per johnny not ready B125 BLDG, FINAL IC 08/22/2007 04:41 PM RH PDA B125 BLDG, FINAL IC Install all hardware. Exposed electrical box in garage. B125 BLDG, FINAL IC Cover walkway area at platform to furnace to prevent B125 BLDG, FINAL IC damage and stepping through ceiling. E150 ELEC, FINAL IC 05/25/2007 12:14 PM JGM PDA E150 ELEC, FINAL IC need to mark nuetral in meter can, light and fan closet E150 ELEC, FINAL IC light in master bath not working E150 ELEC, FINAL IC 05/29/2007 04:24 PM DS PDA E150 ELEC, FINAL IC nuetral still needs to be marked behind meter M100 MECH, ROUGH IN IC 02/05/2007 02:55 PM IDS PDA M100 MECH, ROUGH IN IC. needs to duct exchaust fans to outside P125 PLBG, FINAL IC August 10, 2007 10:23:58 AM glsouth. Page 1 Date: 8/22/2007 Inspection Comments for Finals Permit Year: 6 Permit Number: 3669 Address: 2709 HORSE HAVEN LN Insp. inspection Type code Description p. status Inspection Result Comments B100 BLDG, FOUNDATION -SLAB IC 01/10/2007 05:22 PM RH PDA B100 BLDG, FOUNDATION -SLAB IC Strings up, slab ground installed. B125 BLDG, FINAL IC 08/08/2007 10:03 AM JGM PDA B125 BLDG, FINAL IC cancelled per johnny not ready E150 ELEC, FINAL IC 05/25/2007 12:14 PM JGM PDA E150 ELEC, FINAL IC need to mark nuetral in meter can, light and fan closet E150 ELEC, FINAL IC light in master bath not working E150 ELEC, FINAL IC 05/29/2007 04:24 PM DS PDA E150 ELEC, FINAL IC nuetral still needs to be marked behind meter M100 MECH, ROUGH IN IC 02/05/2007 02:55 PM DS PDA M100 MECH, ROUGH IN IC needs to duct exchaust fans to outside P125 PLBG, FINAL IC August 10, 2007 10:23:58 AM glsouth. Page 1 WF0857704 / 001 City of College Station __-, PAGE 1 REQ. DATE: 12/18/06 12/18/06 12:07:46 LOCATION: 2709 HORSE HAVEN LN LOC ID: 205418 REQUESTOR: OAKWOOD CUSTOM HOMES ORIGIN: CUSTOMER -WALK IN REQ. USER: GLSOUTH AUTH. USER: GLSOUTH WORK TYPE: ROUT SWR 4" WTR 3/411 ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 12/18/06 SCHED COMPLETION: 12/18/06 ******************************************************************************** JOB ORDER RESULT COMMENTS BUILDING PERMIT CITY OF COLLEGE STATION 1101 TE?JAS AIWE COLLEGE STATION, TX 77840 _ PHONE: (979)764-3570 .FAX: (979)764-3496 ---------------------------------- t Number . . . . . Property Address . . . . . . Property ID: R #• Application type description Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . Application valuation . . . . 06-00003669 Date 12/15/06 2709 HORSE HAVEN LN 336300-0201-0050 RESIDENTIAL, 1 UNIT DETACHED NEW HORSE HAVEN PH 2 RESIDENTIAL SINGLE FAMILY RESIDENTIAL 120000 Owner Contractor ------------------------ ------------------------ OAKWOOD CUSTOM HOMES 4060 SH 6 S COLLEGE STATION TX 77845 (979) 690-1504 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 1.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1257.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC TAZ 285.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . KW Permit Fee . . . . 520.00 Plan Check Fee .00 Issue Date . . . . 12/15/06 Valuation . . . . 120000 Expiration Date . . 6/13/07 Qty Unit Charge Per Extension BASE FEE 460.00 20.00 3.0000 THOU BLDG, VAL 100001-500000 60.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" BUILDING DEPT EPRESE�TTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEARS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 06-00003669 Page 2 Date 12/15/06 Special Notes and Comments X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12' ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC ------------------------------------------ ------ --- - -- -.------------ BUILDING DEPT RnEPRE NTATIVE : APPLICANT. lI BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 3 Application Number . . . . . 06-00003669 Date 12/15/06 ---------------------------------------------------------------------------- Special Notes and Comments If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING aSTOGE WATER HEATING -------------------------------------------�-- ---.- - ---------- BUILDING DEPT :PRESENTATIVE: APPLICANT: ���� BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 4 Application Number . . . . . 06-00003669 Date 12/15/06 ---------------------------------------------------------------------------- Special Notes and Comments EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES Narrow Wall Bracing Fully Sheathed ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ---------------------------------------- ----------------- Permit Fee Total 520.00 520.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1270.00 1270.00 .00 .00 BUILDING DEPT PRESENT TIVE: APPLICANT: TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEN -AS AI'E COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 06-00003670 Date 12/15/06 Property Address . . . . . . 2709 HORSE HAVEN LN Property ID: 336300-0201-0050 R #• Application type description TEMP POLE Subdivision Name . . . . . . HORSE HAVEN PH 2 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 0 Owner Contractor ------------------------ ------------------------ OAKWOOD CUSTOM HOMES 4060 SH 6 S COLLEGE STATION TX 77845 (979) 690-1504 --------------------- Structure Information 000 000 -----------------_---- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . KW Permit Fee . . . . 20.00 Issue Date . . . . 12/15/06 Valuation . . . . 0 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total 20.00 20.00 .00 .00 Grand Total 20.00 20.00 .00 .00 ------------------------------------------ ---- -- -------------- BUILDING DEPT RE ESEN ATIVE: APPLICANT: IFar 01fine Use Only APPLICATION FOR BUILDING PERMIT DATE: l 16 TRCC REG CITY OF COLLEGE STATION' APPLICATION # 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 TEMP POLE # bps`/ _'j 6 CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX Planning 0 D-,&p—t S---- WWW.CSTX.GOV / ADDRESS/LOCATION: 2709 HORSE HAVEN LANE J LOT 5 ✓ B1 V/ SUBDIVISION HORSE HAVEN ESTATES LOC�c SEC/PH 2 � BUSINESS/OWNER NAME: ALTON OFCZARZAK PHONE 979-690-1504 CONTRACTOR/HOMEOWNER: OAKWOOD CUSTOM HOMEBUILDERS PHONE:979-690-1504 CONTRACTOR ADDRESS: 4060 HIGHWAY 6 SOUTH COLLEGE STATION, TEXAS 77845 ELECTRICIAN: CAMPISE ELECTRIC PLUMBER: AGGILAND PLUMBING HVAC: THREE RIVERS _ GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION ' MOVING SHELL ONLY DEMOLITION (Asbestos Survey) X NEW CONSTRUCTIONSLAB ONLY DUPLEX (Landscape Plans REMODEURENOVATION* SWIMMING POOL Required) DESCRIPTION OF WORK: NEW CONSTRUCTION i STRUCTURE USE: SINGLE FAMILY RESIDENTIAL HOMEOWNER ASSOC IATION/ARCH ITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: GoaV TEXAS ACCESSIBILITY STANDARS) PROJECT REGISTRATION# EABPRJ �1YALUATION: $ 1 ZO 000 TOTAL AREA: 1563 _ HEATED AREA: 1257 _ V (Cost of abor and Materials) �X PUBLIC SEWER NUMBER OF BEDROOMS: 3 (9e) ❑ SEPTIC/TREATMENT SYSTEM OX SEWER TAP: 4" SIZE I �X WATER TAP: %11 I ❑ OTHER TAP: SIZE SIZE �X TEMP POLE NUMBER OF BATHROOMS: 2 INTERIOR WALL TYPE: 2X4 @ 16 EXTERIOR WALL TYPE FOUNDATION TYPE ROOF TYPE: 2X4 (@ 16 W/ BRICK SLAB & BEAM GARAGE TYPE: SINGLE FX DOUBLE a TRIPLE a ATTACHED FX DETACHED CARPORT 25 YR COMP. SIGNATURE OF APPLICANT: 'If proposed work involves new commercial construction or facade impro ements/renovations to an existing commercial property, building elevations are required. Official Use Only Flo r NO / Y Sor — lr7�Ytaye WI H Plans Examiner Zoning Official Energy Code Compliance Information % Glazing of exterior walls 8% / Insulation R value of exterior walls R13 Insulation R value of ceiling 1 (flat areas) R30 /""' Insulation R value of ceiling 2 (vaulted areas/no attic) R19 Glazing SHGC .30 Glazing U-Factor .54 R value of ductwork R6 A/C SEER Rating 13 4 PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# 0 /10 J �C 69 DATE: / 2, J // � BUILDING ADDRESS: &en/ �✓ I. Foundation Requirements N A. Concrete minimum fc of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier 6 mil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior unless over 60' Ion 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated p II. Framing: Floor, Wall, Ceiling and Roof Requirements "4010 A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex OK 1. One -hour rated extending to roof deck KNOK E. Header sizes indicated on plans F. Emergency bedroom egress 1. Exit direct to outside 2. O enable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. O enable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Exterior wall covering indicated on plans 2. Sheathing indicated on plans 3. Moisture barrier indicated on plans J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, rade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size and spacing and purlin bracing indicated. O. Roof covering used. P. Indicate Wall Bracing Used for Lateral Bracing ,1 PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX II. Framing: Floor, Wall, Ceiling and Roof Requirements continued NAAW P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations S. 18" Overhang allowed on zero lot line construction, perforated soffit allowed. T. Protected openings on walls < three feet from property line K III. Stairway Requirements K A. Stairway Details 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" diff. max. 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8 B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches above handrail 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located four or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four (4) inch sphere IV. Fireplace Requirements to be indicated onplans) A/ 0 K A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must extend at least three (3) feet higher than the highest point where it projects through the roof of a building & at least two (2) feet higher than any portion of the building within ten (10) feet horizontal PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX V. Electrical Service Requirements N A. Electrical plan to include: 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location VI. Plumbing Requirements NAJW A. Pressure reducing valve required when water pressure exceeds 80 psi B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) VIII. Energy Requirements N K A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 N Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements N Maximum drive width for residence is 25' combined for circular 12' minimum Minimum 20 feet from driveway to side(intersecting) street Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 N Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 N Does not block any water course or divert any flow Elevation certificate needed OK J4 4 L ._ p LANS XAMINER DA ov," REScheck Software Version 3.7.3 Compliance Certificate Project Title: HORSEHAVEN LOT 5, BLK 1, PH2 Report Date: 11/24/06 Data filename: G:\OAK DWG\HORSEH-3\HH5-27-1\HH5-27-1.RCK Energy Code: 20031ECC Location: College Station, Texas Construction Type: Single Family Glazing Area Percentage: 8% Heating Degree Days: 1788 Construction Site: 2709 HORSEHAVEN LANE College Sataion, TX 77845 Permit # Permit Date Owner/Agent: Designer/Contractor: ALTON OFCZARZAK David Park OAKWOOD CUSTOM HOMES GROUP OAKWOOD CUSTOM HOMES GROUP LTD. LTD. HOME PLAN DESIGN SERVICE 4060 HWY. 6 SOUTH 4060 Highway 6 South COLLEGE STATION, TX 77845 College Station, TX 77845 979-690-1504 979-690-1504 PLANS@OAKCHB.COM plans@oakchb.com Compliance: Passes Maximum UA: 595 Your Home UA 440'M26'Kll. Better Than C_oode (UA7 Ma)dmum SHGC: 0.40 0.30 Ceiling 1: Flat Ceiling or Scissor Truss: 1257 0.0 30.0 39 Wall 1: Wood Frame, 16" o.c.: 1603 13.0 0.0 116 3050 X7: Metal Frame:Double Pane with Low-E: 105 0.540 57 SHGC: 0.30 1008: Metal Frame:Double Pane with Low-E: 2 0.540 1 SHGC: 0.30 2030: Metal Frame:Double Pane with Low-E: 6 0.540 3 SHGC: 0.30 4050: Metal Frame:Double Pane with Low-E: 20 0.540 11 SHGC: 0.30 3068 FRONT DOOR: Solid: 20 0.140 3 2868 BACK DOOR: Solid: 18 0.140 3 2868 TO GARAGE: Solid: 18 0.140 3 CONC. SLAB: Slab-On-Grade:Unheated: , Insulation Depth: 0.0' 196 0.0 204 Heat Pump 1: Air Source: 7.7 HSPF, 14 SEER Air Conditioner 1: Electric Central Air. 14 SEER Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2003 IECC requirements in REScheck Version 3.7.3 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. �- OaLVIwoodco S�, 2 b T o Builder/Designer Company Name Date Project Notes: LOT 5, BLOCK 1, PHASE 2 HORSEHAVEN ESTATES _ZZ09— RSEHA N LANE HORSEHAVEN LOT 5, BLK 1, PH2 Page 1 of 5 STEELDUST HORSEHAVEN LOT 5, BLK 1, PH2 Page 2 of 5 ciREScheck Software Version 3.7.3 Inspection Checklist Date: 11 /24/06 Ceilings: ❑ Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 continuous insulation Comments: Above -Grade Walls: ❑ Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation Comments: Windows: ❑ 3050 X7: Metal Frame:Double Pane with Low-E, U-factor: 0.540 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ 1008: Metal Frame:Double Pane with Low-E, ll-factor. 0.540 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ 2030: Metal Frame:Double Pane with Low-E, U-factor. 0.540 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ 4050: Metal Frame:Double Pane with Low-E, U-factor. 0.540 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: Doors: ❑ 3068 FRONT DOOR: Solid, U-factor. 0.140 Comments: ❑ 2868 BACK DOOR: Solid, U-factor: 0.140 Comments: ❑ 2868 TO GARAGE: Solid, U-factor. 0.140 Comments: Floors: ❑ CONC. SLAB: Slab-On-Grade:Unheated, R-0 (uninsulated) Comments: Heating and Cooling Equipment: ❑ Heat Pump 1: Air Source: 7.7 HSPF, 14 SEER or higher Make and Model Number: ❑ Air Conditioner 1: Electric Central Air. 14 SEER or higher Make and Model Number: Solar Heat Gain Coefficient: HORSEHAVEN LOT 5, BLK 1, PH2 Page 3 of 5 n ❑ The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values must be determined in accordance with the NFRC test procedure or taken from the default table. Alr Leakage: ❑ Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. ❑ Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a 3" clearance from insulation. Skylights: ❑ Minimum insulation requirement for skylight shafts equal to or greater than 12 Inches is R-13. Materials Identification: ❑ Materials and equipment must be installed in accordance with the manufacturer's installation instructions. ❑ Materials and equipment must be identified so that compliance can be determined. ❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. ❑ insulation R-values, glazing U-factors, and cooling equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: ❑ Supply ducts in unconditioned attics or outside the building must be insulated to R-8. ❑ Return ducts in unconditioned attics or outside the building must be insulated to R-4. ❑ Supply ducts in unconditioned spaces must be insulated to R-6. ❑ Return ducts in unconditioned spaces (except basements) must be insulated to R-2. ❑ Where exterior walls are used as plenums, the wall must be insulated to R-8. ❑ Insulation is not required on return ducts in basements. Duct Construction: ❑ Dud connections to flanges of air distribution system equipment must be sealed and mechanically fastened. ❑ All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), masbc,plus-embedded-fabric, or tapes. Tapes and mastics must be rated UL 181A or UL 181B. Exception: Continuously welded and locking -type longitudinal joints and seams on duds operating at less than 2 in. w.g. (500 Pa). ❑ The HVAC system must provide a means for balancing air and water systems. Temperature Controls: ❑ Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Service Water Heating: ❑ Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. ❑ Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: ❑ Insulate circulating hot water pipes to the levels in Table Swimming Pools: ❑ All heated swimming pools must have an onloff heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: ❑ HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F must be insulated to the levels in Table 2. HORSEHAVEN LOT 5, BLK 1, PH2 Page 4 of 5 • -3 Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness In Inches by Pipe Sizes Non -Circulating Runouts Circulating Mains and Runouts Heated Water Temperature ("F) Up to 1" Up to 1.25" 1.5" to 2.0" Over 2" 170-160 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes Insulation Thickness In Inches by Pipe Sizes Fluid Temp. Piping System Types Range("F) 2" Runouts 1" and Less 1.25" to 2.0" 2.5" to 4" Heating Systems Law Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 106-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant and 40-55 0.5 0.5 0.75 1.0 Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD: (Building Department Use Only) HORSEHAVEN LOT 5, BLK 1, PH2 Page 5 of 5