PREPARED 7/06/07, 12:52:06 INSPECTION TICKET PAGE 1
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 7/06/07
------------------------------------------------------------------------------------------------
ADDRESS . : 5213 BALLYBUNION LN SUBDIV: PEBBLE CREEK
CONTRACTOR BENCHMARK - DBA G D T INC PHONE (979) 690-7117
OWNER . . PHONE
PARCEL . . 497900-0947-0170
APPL NUMBER: 06-00003660 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 1/23/07 JGM BLDG, FOUNDATION -SLAB TIME: 17:00
1/23/07 AP January 22, 2007 2:15:10 PM ncochran.
loam please
Strings On Setbacks O.K.
Slab Ground Installed
B115 01 2/26/07 RH BLDG, FRAMING TIME: 17:00
2/27/07 AE February 26, 2007 3:14:07 PM kwolfe.
February 27, 2007 4:28:52 PM kwolfe.
FIREPLACE FLUE MUST MAINTAIN 2" OF CLEARANCE FROM
COMBUSTIBLE (BETWEEN FLOORS). nEED A CHASE AROUND A/C DUCT
IN UPSTAIRS BATHROOM.
February 27, 2007 4:29:34 PM kwolfe.
B 30i01 3/06/07 BH BLDG, INSULATION TIME: 17:00
3/06/07 AP March 6, 2007 9:26:58 AM kwolfe.
March 6, 2007 9:27:14 AM kwolfe.
B125 01 6/29/07 JGM BLDG, FINAL TIME: 17:00
6/29/07 DA June 29, 2007 11:24:04 AM kwolfe.
attic insulation has not been blown in yet....
06/29/2007 04:28 PM JGM PDA
need address, openings for guardrail on stairs over 4"
wide, need proper hardware on doors, did not fix elec.
notes, need proper drainage away from slab
B125 02 7 06/ 7 BI BLDG, FINAL TIME: 17:00
July 6, 2007 12:51:36 PM glsouth.
--------------- COMMENTS AND NOTES
_ _ _ _.
Terry Bonskie Re CaIlmgYfor CO @ 5213 Ballybunion ,Lr .r Page 1
From: Paul Schoenfeld
To: Amber Carter; Benjamin McCarty; Chris Haver;
Date: 6/29/2007 3:19 pm
Subject: Re: Calling for CO @ 5213 Ballybunion Ln
ALL OK.
PAUL
>>> Kim Wolfe 6/29/2007 12:03 PM >>>
any issues?
BP # 06-3660
Thanks
Kimberly Wolfe, CPS/CAP
City of College Station
Planning & Development Services
(979)764-3570
www.csbc.gov
Date: 7/6/2007
Inspection Comments for Finals
Permit Year: 6 Permit Number: 3660
Address: 5213 BALLYBUNION LN
Insp.
inspection Type Code
Description
p.
status
Inspection Result Comments
B100
BLDG, FOUNDATION -SLAB
IC
Strings On Setbacks O.K.
B100
BLDG, FOUNDATION -SLAB
IC
Slab Ground Installed
B115
BLDG, FRAMING
IC
February 27, 2007 4:28:52 PM kwolfe.
B115
BLDG, FRAMING
IC
FIREPLACE FLUE MUST MAINTAIN 2" OF CLEARANCE
FROM
B115
BLDG, FRAMING
IC
COMBUSTIBLE (BETWEEN FLOORS). nEED A CHASE
AROUND A/C DUCT
B115
BLDG, FRAMING
IC
IN UPSTAIRS BATHROOM.
B115
BLDG, FRAMING
IC
February 27, 2007 4:29:34 PM kwolfe.
B125
BLDG, FINAL
IC
06/29/2007 04:28 PM JGM PDA
B125
BLDG, FINAL
IC
need address, openings for guardrail on stairs over 4"
B125
BLDG, FINAL
IC
wide, need proper hardware on doors, did not fix elec.
B125
BLDG, FINAL
IC
notes, need proper drainage away from slab
B130
BLDG, INSULATION
IC
March 6, 2007 9:27:14 AM kwolfe.
E110
ELEC, ROUGH IN
IC
February 27, 2007 4:28:34 PM kwolfe.
E150
ELEC, FINAL
IC
06/29/2007 12:32 PM RH PDA
E150
ELEC, FINAL
IC
Remove ceiling fan from over master tub by building final.
M110
MECH, FINAL
IC
06/29/2007 04:26 PM JGM PDA
M110
MECH, FINAL
IC
vent hood not completed, missing grills
Page 1
r`/
(31612007) Kim Wol11 fe - Insulation request inspection result, 5213 Ballybunion, #06-3660 Page 11
From: Brian Henry
To: Southerland, Gina
Date: 3/6/2007 8:25 AM
Subject: Insulation request inspection result, 5213 Ballybunion,#06-3660
CC: Cochran, Nicole; Wolfe, Kim
Print for file
Inspected insulation, 5213 Ballybunion, #06-3660, Benchmark Homes, 3-6-07
Inspection result: Inspected OK for Good Cents
WF0859291 / 001 City of College Station
PAGE 1
REQ. DATE:
12/21/06
12/21/06
11:56:09
LOCATION:
5213 BALLYBUNION LN
LOC ID:
205870
REQUESTOR:
BENCHMARK - DBA G D T 'INC ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER: KWOLFE
WORK TYPE:
ROUT
TEMP POLE
PASSED
TASK:
SET UP NEW UTILITY ACCT SET
READY
SCHED START:
12/21/06 SCHED COMPLETION:
12/21/06
********************************************************************************
JOB ORDER RESULT COMAENTS e2 f (Vt)
v
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION(Q�Q�
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
------------------------------------------------------------------
Application Number . . . . . 06-00003661 Date 12/18/06
Property Address . . . . . . 5213 BALLYBUNION LN
Property ID: 4,97900-0947-0170
R #: R
Application type description TEMP POLE
Subdivision Name . . . . . PEBBLE CREEK
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 0
Owner
------------------------
Contractor
------------------------
BENCHMARK - DBA G
D T INC
1110 12TH MAN CIR
COLLEGE STATION
TX 77845
---------------------------------------------------------------
(979) 690-7117
Permit . . . . .
. TEMP POLE
PERMIT
Additional desc .
. GS
Permit Fee . . .
. 20.00
Issue Date . . .
--------------------------------------------------------------
. 12/18/06
Valuation . . .
. 0
Other Fees . . .
---------------------------------------------------------------
. . . . . .
TEMP ELECT POLE CONNECT
45.00
Fee summary
---------------
Charged
----------
Paid Credited
Due
'Permit Fee Total
20.00
---------- ----------- ----------
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
-------------------
BUILDING DE
APPLICANT:
F,
WF0864564 / 001 City of College Station PAGE 1
REQ. DATE:
01/09/07
01/09/07
8:57:05
LOCATION:
5213 BALLYBUNION LN
LOC ID:
205870
REQUESTOR:
BENCHMARK ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
GLSOUTH AUTH. USER: GLSOUTH
WORK TYPE:
ROUT
SWR 4"
WTR 3/4"
TASK:
SET UP NEW UTILITY ACCT SET
READY
SCHED START:
01/09/07 SCHED COMPLETION:
01/09/07
********************************************************************************
JOB ORDER RESULT COMMENTS
BUILDING—E'i MIT
CITY OF COLLZOEJ34TATION
1101 TEXAS AVE
COLLEGE STATION/TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number
06-00003660
Date 1/09/07
Property Address . .
. . . . 5213 BALLYBUNION LN
Property ID:
497900-0947-0170
R #:
R
Application type description
RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . .
. . . . PEBBLE CREEK
Property Use . . . .
. . . . RESIDENTIAL
Property Zoning . . .
. . . . SINGLE FAMILY RESIDENTIAL
Application valuation
228800
Owner
Contractor
------------------------
------------------------
BENCHMARK - DBA G
D T INC
1110 12TH MAN CIR
COLLEGE STATION
TX 77845
(979) 690-7117
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
3468.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
3.00
NUMBER OF BEDROOMS
5.00
SEWER TYPE
PUBLIC
TAZ
419.00
--
--------------------------
Permit . . . . . .
----------------------------------
BUILDING PERMIT
--------------
Additional desc . .
GS
Permit Fee . . . .
847.00 Plan Check Fee
.00
Issue Date . . . .
1/09/07 Valuation . .
. . 228800
Expiration Date . .
7/08/07
Qty Unit Charge Per Extension
BASE FEE 460.00
129.00 3.0000 THOU BLDG, VAL 100001-500000 387.00
-----------------------------------------=--=--------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 2211
-------------------------------------------- ------ --- --.-----------
BUILDING DEPT RE ESEN TI
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE 6TATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 06-00003660
Page 2
Date 1/09/07
Special Notes and Comments
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
BUILDING DE
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE .0TATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 06-00003660
Page 3
Date 1/09/07
Special Notes and Comments
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 150 of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
STAIRS SHALL COMPLY WITH SECTION R-311 (2003 IRC) WITH A
CONTINUOUS HANDRAIL OR SECTION
1009 (2003 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL
NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A
NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS.
BUILDING DE
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page
4
Application Number . . . . . 06-00003660 Date
1/09/07
----------------------------------------------------------------------------
Special Notes and Comments
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND
LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003
IRC)
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
Narrow Wall Bracing Fully Sheathed with Modified Garage to
get 27" Minimums to allow Regular Framing.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Pee summary Charged Paid Credited Due
----------------------------------------
-----------------
Permit Fee Total 847.00 847.00 .00
.00
Plan Check Total .00 .00 .00
.00
Other Fee Total 750.00 750.00 .00
.00
Grand Total 1597.00 1597.00 .00
.00
---------------------------- ------------------------------
BUILDING DEPT REPRESENTATIVE: /; /4 . / •
APPLICANT:
� 1
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX
Plannint6Development Service; WWW CSTX.GOV
F rO ce Use'Only
DATE: R /R G
APPLICATION # rV
TEMP POLE #
ADDRESS/LOCATION:r2l_ /�/��D►�JG, /
LOT _17 -`BLOCK ` ,,Il 7 " SUBDIVISION �bbl (� SEC/PH -/—D
BUSINESSIOWNER NAME: e;ZaAfC_ i I PHONE: ` 1Z7 I71
CONTRACTOR/HOMEOWNER: ,�NGt��tr-k 2aM�e2 PHONE:. �10 -1117
CONTRACTOR ADDRESS: 11 t 7) I Z 4k &AI iraI12 CS 7 7ft5
ELECTRICIAN: `C_� PLUMBER: US 71;fT_
HVAC: GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION " SLAB ONLY
DUPLEX (Landscape Plans REMODEURENOVATION* SWIMMING POOL
Required)
DESCRIPTION OF WORK: I All �� Z A-M ; A,
STRUCTURE USE:
USE:
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STAN RD (TAS) �OJECT REGISTRATION# EABPRJ
VALUATION: $ 2. / TOTAL AREA:HEATED AREA
(Cost ofrab& and Materials)
M PUBLIC SEWER
SEPTIC/TREATMENT SYSTEM
`-t'
SEWER TAP: 4 M`
SIZE
WATER TAP: Ij
SIZE
OTHER TAP:
SIZE
TEMP POLE
GARAGE TYPE: SINGLE EJ
ATTACH
NUMBER OF BEDROOMS
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
DOUBLE El
TRIPLE
OWN
om
SIGNATURE OF APPLICANT:
*If proposed work involves new commercia construction or facade improvements/renovations to an existing
commercial property, building elevations are required.
Official Use Only
C ents:
ES r NO
Plans Examiner Zoning Official
�'YIP
-t�2 S
gd4 A7 wl4v,"s,UNf
4
d
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# �/ _ A 6 0
DATE: —0(p
BUILDING ADDRESS: (p
I. Foundation Requirements
NA/45)0
A.
Concrete minimum fc of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier 6 mil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior unless over 60' Ion
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F.
Wood foundation details indicated
tff4#OK
II. Framing: Floor, Wall, Ceiling and Roof Requirements
NA/
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
OK
1. One -hour rated extending to roof deck
OK
E.
Header sizes indicated on plans
OK
F.
Emergency bedroom egress
1. Exit direct to outside
2. O enable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
O enable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, rade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
N.
O.
P.
Span exceeding code tables must be engineered
Rafter size and spacing and purlin bracing indicated.
Roof covering used.
Indicate Wall Bracing Used for Lateral Bracing
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
II. Framing: Floor, Wall, Ceiling and Roof Requirements continued
N
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
S. 18" Overhang allowed on zero lot line construction, perforated soffit allowed.
T. Protected openings on walls < three feet from property line
OK
/�-
III. Stairway Requirements
N
A. Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" diff. max.
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches above handrail
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located four or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four (4) inch sphere
IV. Fireplace Requirements to be indicated onplans)
W019
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening ? 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must extend at least three (3) feet higher than the highest point where it
projects through the roof of a building & at least two (2) feet higher than any portion of the
building within ten (10) feet horizontal
0
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
V. Electrical Service Requirements
NA/
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
VI. Plumbing Requirements
A/
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N A. CC K
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units)
T
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
N
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N O
Maximum drive width for residence is 25' combined for circular 12' minimum
Minimum 20 feet from driveway to side(intersecting) street
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N O
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
N
Does not block any water course or divert any flow
Elevation certificate needed
OAJb K
P E -
MINER
I z'g- 06
DATE
95.00'
0
Lo
95.00'
FLAN
FOR PEBBLE CREEK HEATED AREA, 3 468 so. Fr. BENCHMARK HOMES
5 I TE I L AI V LOT: 17 PHASE 9D GLENN THOMAS
SCALE, �, m 20, BLOCK: 47 5213 BALLYBUNION SLAB AREA, 31577 SO. FT. FWME. FAX.
(409) cao-nn (409) 6w-nie
c S
Permit #
Permit Date
REScheck Software Version 3.7.3
Compliance Certificate
Project Title: Benchmark Homes Job 291
Report Date: 12/05/06
Data filename: C:\Documents and Settings\AII Users\Documents\REScheck docs\291 BM.rck
Energy Code: 2000 IECC
Location: College Station, Texas
Construction Type: Single Family
Glazing Area Percentage: 11%
Heating Degree Days: 1788
Construction Site: Owner/Agent: Designer/Contractor:
5213 Ballybunion Lane
College Station, TX 77845
Permit Date: December 8, 2006
,compliance. Passes Maximum UA: 1134 Your Home UA: 851=> 2510%alBetter Than Codei(UA)]Maximum SHGC: 0.40 Your SHGC: 0.34
Ceiling 1: Flat Ceiling or Scissor Truss:
Wall 1: Wood Frame, 16" o.c.:
Window 1: Metal Frame:Double Pane with Low-E:
SHGC: 0.34
Door 1: Solid:
Door 2: Glass:
SHGC: 0.33
Floor 1: Slab -on -Grade: Unheated: , Insulation Depth: 0.0'
Furnace 1: Forced Hot Air: 80 AFUE
Air Conditioner 1: Electric Central Air: 14 SEER
2964 30.0
0.0 104
3410 13.0
0.0 247
326
0.650 212
24
0.140 3
53
0.310 16
258
0.0 269
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in
REScheck Versio 3.7.3 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Builder/Designer Company Name �tJL> Date
Project Notes:
BM Job #291
Lot 17 Block 47 Pebble Creek 9D
5213 BallyBunion Lane
College Station, TX 77845
GDT Incorporated
dba Benchmark Homes
1110 12th Man Court
College Station, TX 77845
Similar to 2414 Norham & 2495 Newark
Benchmark Homes Job 291 Page 1 of 4
A
CREScheck Software Version 3.7.3
�(j Inspection Checklist
Date: 12/05/06
Ceilings:
❑ Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation
Comments:
Above -Grade Walls:
❑ Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation
Comments:
Windows:
❑ Window 1: Metal Frame:Double Pane with Low-E, U-factor: 0.650
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
Doors:
❑ Door 1: Solid, U-factor: 0.140
Comments:
❑ Door 2: Glass, U-factor: 0.310
Comments:
Floors:
❑ Floor 1: Slab-On-Grade:Unheated, R-0 (uninsulated)
Comments:
Heating and Cooling Equipment:
❑ Furnace 1: Forced Hot Air. 80 AFUE or higher
Make and Model Number:
❑ Air Conditioner 1: Electric Central Air: 14 SEER or higher
Make and Model Number:
Solar Heat Gain Coefficient:
❑ The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values must be
determined in accordance with the NFRC test procedure or taken from the default table.
Air Leakage:
❑ Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed.
❑ Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from
combustible materials. If non -IC rated, the fixture must be installed with a 3" clearance from insulation.
Materials Identification:
❑ Materials and equipment must be installed in accordance with the manufacturer's installation instructions.
❑ Materials and equipment must be identified so that compliance can be determined.
❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided.
❑ Insulation R-values, glazing U-factors, and heating and cooling equipment efficiency must be clearly marked on the building
plans or specifications.
Duct Insulation:
Benchmark Homes Job 291 Page 2 of 4
is
❑ Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-8.0.
Duct Construction:
❑ All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives),
mastic -plus -embedded -fabric, or tapes. Tapes and mastics must be rated UL 181A or UL 181 B.
Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500
Pa).
❑ The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
❑ Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the
heating and/or cooling input to each zone or floor shall be provided.
Service Water Heating:
❑ Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral
heat trap or is part of a circulating system.
❑ Insulate circulating hot water pipes to the levels in Table 1.
Circulating Hot Water Systems:
❑ Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
❑ All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from
non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
❑ HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F must be insulated to the levels in Table
2.
Benchmark Homes Job 291 Page 3 of 4
. -A
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes
Insulation Thickness in Inches by Pipe Sizes
Non -Circulating Runouts
Circulating Mains and Runouts
Heated Water
Temperature ("F)
Up to 1"
Up to 1.25"
1.5" to 2.0"
Over 2"
170-180
0.5
1.0
1.5
2.0
140-169
0.5
0.5
1.0
1.5
100-139
0.5
0.5
0.5
1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes
Insulation Thickness in Inches by Pipe Sizes
Fluid Temp.
Piping System Types
Range("F)
2" Runouts 1" and Less
1.25" to 2.0" 2.5" to 4"
Heating Systems
Low Pressure/Temperature
201-250
1.0
1.5
1.5
2.0
Low Temperature
120-200
0.5
1.0
1.0
1.5
Steam Condensate (for feed water)
Any
1.0
1.0
1.5
2.0
Cooling Systems
Chilled Water, Refrigerant and
40-55
0.5
0.5
0.75
1.0
Brine
Below 40
1.0
1.0
1.5
1.5
NOTES TO FIELD: (Building Department Use Only)
Benchmark Homes Job 291 Page 4 of 4