HomeMy WebLinkAboutRES2006-03640, 06-3641From: Terry Boriskie To: banderson@stylecraft-builders.com; Benjamin McCarty; Chris Haver; Gin... Date: 6/7/2007 12:56 PM Subject: Re: Calling for C.0 @ 2321 Carisbrooke Loop Stylecraft has been notified of the needed repairs. Terry Boriskie City of College Station Residential Plans Examiner 979-764-3744 >>> Paul Schoenfeld 6/7/2007 10:39 am >>> Water ok. Sewer buried Flagged. Paul >>> Gina Southerland 6/6/2007 11:58 AM >>> BP# 06-3640 Gina Southerland CSR - Planning & Development Services City of College Station 979-764-3570 www.cstx.goV PREPARED 6/06/07, 11:44:11 INSPECTION TICKET PAGE 3 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 6/06/07 ------------------------------------------------------------------------------------------------ ADDRESS . : 2321 CARISBROOKE LOOP SUBDIV: CASTLEGATE SEC 10,11,12,13 CONTRACTOR STYLECRAFT BUILDERS PHONE (979) 690-1222 OWNER STYLECRAFT BUILDERS INC PHONE PARCEL 184200-0131-0040 APPL NUMBER: 06-00003640 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 1/10/07 OC BLDG, FOUNDATION -SLAB TIME: 17:00 1/10/07 AP January 10, 2007 9:00:32 AM glsouth. Strings On Setbacks O.K. Slab Ground Installed .. ,.B1'15 01 2/28/07 JGM BLDG, FRAMING TIME: 17:00 2/28/07 DP February 27, 2007 8:47:39 AM ncochran. Garage APA Portal Framing Incorrect B115 0 3/07/07 RH BLDG, FRAMING TIME: 17:00 3/07/07 AE March 7, 2007 8:21:29 AM ncochran. 03/07/2007 04:03 PM RH PDA Need to add straps on the inside of garage. The splice in the panels must be within 2ft of the mid height as per APA requirements. Left drawings of APA requirements on site. Make corrections by insulation inspection. B130 01 3/14/07 RH BLDG, INSULATION TIME: 17:00 3/14/07 AP March 13, 2007 2:59:51 PM ncochran. B125 01 ZO 1/07 BI BLDG, FINAL TIME: 17:00 4 1 June 6, 2007 11:11:00 AM glsouth. ---------- ---- --------- 4-It --------- CONTINUED ONTO NEXT PAGE --------------------------- TJV1�� t W/X10 Gq Date: 6/6/2007 Inspection Comments for Finals Permit Year: 6 Permit Number: 3640 Address: 2321 CARISBROOKE LOOP Insp. Inspection Type Code Status s Inspection Result Comments B100 BLDG, FOUNDATION -SLAB IC Strings On Setbacks O.K. B100 BLDG, FOUNDATION -SLAB IC Slab Ground Installed 13115 BLDG, FRAMING IC Garage APA Portal Framing Incorrect B115 BLDG, FRAMING IC 03/07/2007 04:03 PM RH PDA B115 BLDG, FRAMING IC Need to add straps on the inside of garage. The splice in B115 BLDG, FRAMING IC the panels must be within 2ft of the mid height as per B115 BLDG, FRAMING IC APA requirements. Left drawings of APA requirements on B115 BLDG, FRAMING IC site. Make corrections by insulation inspection. E110 ELEC, ROUGH IN IC February 27, 2007 3:53:19 PM kwolfe. P125 PLBG, FINAL IC 05/04/2007 11:51 AM JGM PDA P125 PLBG, FINAL IC test not holding Page 1 Dec 12 06 02:37p Cch - B/cs Dec 05 06 04:19p HTG �, ' 9 979 690 3823 817-354-1451 p.4 p.3 S U R V E Y P L A T This is tn2447 tify that I have, this ate, made an on the ground surrey of the property located NEWARK CIRLCE . the City of COLLEGE STATION. Texas, described as follows: Lot 4, Block 2, of CASTLEGATE SUBDMS40N SECTION 5, Phase 1, an Addition to the City of College Station, Brazos County. Texas, according to the Plat thereof recorded in Volume 6192, Page 200, of the Plat Records of Brazos County. Texas_ �GV 1d 11 - a 9Z oMI200 / ? 4j /me' 4 2C GLOB. LLME V=ME 6t02, Pr. 200 o- a° t.r zr aoM NOSES: 2. Basis of Bearing - Subject Plat 3. C.M. a CONTROLLING MONUMENT m BUXL U►E 7s 7.19 B= UME VbARE MUZ Pr. no vain 20, PALE. E SUZ M 202 9 Te y Ey� •4s WJlliam .R., PriCe S iZ-l -ale noao COMMAie N aesmnr q tlr piAOD p6t.GlM°E RIDE YAVS �. . tonti V+o wA1� PmPb 0v Mr me .AWn o ipuM Road lbod Aa (td0 Vow Raadh Map dab oo-°�a°oo a�ra.� Pair ee. aos�amo� o d�a r� r�ma � tr. �c TEa *2 b,o. 4 a M emael aad —A. ApraeAtl.n of b P 0 b v Ord by f.rno0— W nYh4nu IAae Syr M of �mR W rw ad dYorrWr d wd pwprb Yaq bAef�d yr VM Nd Iso d baalkn ar b7r d mAA.°. aM antlleo'4 all d Wep dMda er sa�edr d 0n papy ar 6ed� tlnn PNrb Yr qu dMmea ldleol�4 ar h dlMano 0vn tlr oear4 itwwcCn r Wdbd ho w (2-- drel r tld plot. 11w� a� ro Mib errte0p or pa6uWir s�¢ s rvwa warm P. Prioa Ntl.a1.d lean Ma. 3M &NG BUENA TIERRA. GROUP 06-'� SUMEYM • COIrsu 7MG • HAMAG�$ ' 400 SOUTH INDUSTRIAL BOULEVARD SUITE 216 (817) 354-1445 ,• - �' EULESS, TEXAS 76040 (617) 354-1451 (h °RAtaN BY: YAL7. WF0867322 / 001 City of College Station PAGE 1 REQ. DATE: 01/22/07 01/22/07 10:45:17 LOCATION: 2321 CARISBROOKE LOOP LOC ID: 198334 REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN REQ. USER: NCOCHRAN AUTH. USER: NCOCHRAN WORK TYPE: ROUT' TEMP POLE PASSED TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 01/22/07 SCHED COMPLETION: 01/22/07 ******************************************************************************** JOB ORDER RESULT COMMENTS ski WF0855633 / 001 City of College Station PAGE 1 REQ. DATE: 12/08/06 12/08/06 16:18:04 LOCATION: 2321 CARISBROOKE LOOP LOC ID: 198334 REQUESTOR: STYLECRAFT BUILDERS, INC ORIGIN: CUSTOMER -WALK IN REQ. USER: NCOCHRAN AUTH. USER: NCOCHRAN WORK TYPE: ROUT 4" SWR TAP 3/4" WTR TAP TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 12/08/06 SCHED COMPLETION: 12/08/06 ******************************************************************************** JOB ORDER RESULT COMMENTS From:STYLECRAFT BUILDERS INC 979 690 0348 08/02/2007 08:45 #143 P.002/004 Rug 02 07 07:47a Paul Williams Land Survey 9797797672 p.2 U.S. DEPARTMENT OF HOMO-AND SECURITY ELEVATION CERTIFICATE + OMB No. 1660-0008 Federal Emergency Management Agency I Emires February 28. 2009 i National Flood Insurance Program Important:' Read the instructions on pages 1-8. SECTION A - PROPERTY N1. DYNYYIIj Vw1ICl :i IVAr11C - Stylacraft Builders A2 BuildingStreet Address Irt g ) (cludrng Apt., Unit, Suite, and/or Bldg. No. or P.O. Route and Box Na. 2321 Carisbrooke Loop City. State - ZIP Code College Station Texas 77840 A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.)-� Castlegate, Section A L.ot4, Block 1 A,& Building Use (e g., Residential, Non -Residential, Addition, Aocessory, etc.) Residence A5. LatihndeA.onghx e: Lat. N 30232.850' Long. W 96216-%6' Horizontal Datum: ❑ NAD 1927 NAD 1983 A6. Attach at least 2 photographs of the building ti the Certificate is being used to obtain flood insurance. A7. Building Diagram Number 1_ A& For a bufdbng with a crawl space or enclosure(s), provide: A9. For a building with an attached garage, provide: a) Square footage of crawl space or enclosure(s) sq ft a) Square footage of attached garage sq ft b) No. of permanent flood openings In the crawl space or b) No. of permanentflood openings in the attached garage enclosure(s) walls within 1.0 toot above adjacent grade waft within 1.0 toot above adjacent grade c) Total not area of flood openings in A8.b sq in c) Total net area of flood openings In A9.b sq in SECTION B - FLOOD INSURANCE RATE MAP (FIRM) INFORMATION B1, NFIP Community Name js Community Number B2.County Name B3, State College Station 480083 Brazos I Texas 84. Map/Panel Number B5. Suffix B6. FIRM Index B7. FIRM Panel B& Flood 59. Base. Rood Bevation(s) (Zone Date Effe�:tivalRevised Date Zone(s) AO, use base flood depth) 48041COMS D 7-2-92 2-9-2000 AE 306.5 VIM* Indicate the source of the Base Flood Elevation (BFl7 data or base flood depth entered in Item 89. ❑ FIS Profile 0 FIRM ❑ Community Determined ❑ Other (Describe) B11. Indicate elevation datum used for BFE in Item B9: ❑ NGVD 1929 NAVD 19M ❑Other (Describe) B12. Is the buiding located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? ❑ Yes . No Designation Date [] CBRS ❑ OPA SECTION C - BUILDING ELEVATION INFORMATION (SURVEY REQUIRED) C1. Budding elevations are based on: ❑ Construction Drawings" ❑ M admg Under Construction- Finished Constnxtion 'A new Bevatfon Certificate wit be required when constnwilon of the building is complete. C2. Elevations -Zones Al -AM AE, AH. A (with BFE). VE. V1-V30, V (with BFE7, AR, ARIA, ARIAS. ARIA1-A30, AR/AH, AR/AO. Complete items C2.a-g below according to the building diagram apeci8ed in IlEarn A7. Benchmark Utilized CS 137 (City of College Station) Vertical Datum NAD 88 Converskm/Comments Subdivision BM Check the measmernent used. a) Top of bottom floor (including basement, crawl space, or enclosure floor) 308.44 . feet ❑ meters (Puerto Rico only) b) Top of the next higher floor --�❑t feet ❑ meters (Puerto Rico only) c) Bottom of the lowest horizontal structural member (V Zones only) feet ❑ meters (Puerto Rico only) d) Attached garage (top of stab) l feet meters (Puerto Rico only) Lowest elevation of machiner�oeoiLA-mrteir-9-tb-eJ&fl-ding_- .--._ated--_-nmetecs_(2uejdD-B!Co_oollt). -- -- — — -- (Describe type of equipment in Cownments) 0 Lowest adjacent (finished) grade (LAG) 305-58—Mfeet ❑ meters (Puerto Rico only) g) Highest adjacent (finished) grade (HAG) 30821--M feet ❑ meters (Puerto Rico only) SECTION D-SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION t nos certification is to oe signed and seated by a iano surveyor, engineer, or architect authorized by law to certify elew information. I certify thatthe brfarmaf/on on this Certftafe represents my bust efforts to frrferpret due data avallabkL I understand that any false statement maybe punishable by fine or imprisonment raider 18 U.S. Code, Section 1001. ❑-Chedchere if comments are provided on back of form. Name Number Title Company Name Surveyor Pall Williams Land Survevind Co Address City Stake ZtP Code 30 So In Stmet, Ste.206 Texas 77803 Sl are Date Telephone -27-07 979-779-7670 FFJl A Fonn 81-31, Febmary 2005 See. reverse side for continuation. Replaces all previous editions From:STYLECRAFT BUILDERS INC 979 690 0348 08/02/2007 08:45 #143 P.004/004 nug 02 07 07:47a Paul Williams Land Survey 9797797672 P,4 Building Photographs Continuation Page ):sir fhs&arice CCittipartiy U 9: Building Street Address (including Apt., Unit, Sufte, and(or Bldg. No_) or P.O. Route and Box No. Policy.Nurntier. . 2321 C~arisbrocke Loop City State ZIP Code Otiiiipaii ►NA7C Number , :: >.` . It submitting more photographs than will fit on the preceding page, affix the additional photographs below. Identify all photographs with: date taken; `Front View' and "Rear View"; and, if required, "Right Side Yew" and "Left Side View." Low Elevation ` From:STYLECRAFT BUILDERS INC 979 690 0348 08/02/2007 08:45 #143 P.003/004 Aug 02 07 07:47a Paul Williams Land Survey 9797797672 p,3 Building Photographs See Instructions for Item A6. For fnturanca rzmpany wk#c: - Building Street Address (including Apt, Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number 2321 Carfsbroake Loop City State zip code yf`*A I* If using the Elevation Certificate to obtain NFIP flood insurance, affix at least two building photographs below according to the instructions for Item A6. Identify all photographs with: date taken; "Front View" and "Rear View", and, if required, "Right Side View" and "Left Side View_" If submitting more photographs than will fit on this page, use the Continuation Page, following. Final Floor Elevation High Elevation / From:STYLECRAFT BUILDERS INC 979 690 0348 06/22/2007 15:02 #124 P.001/001 Jan 05 07 11 : 30a Paul Wr ? iams Land Survey 9797797G---- (o. Z U.S. DEPARTMENT OF HOMELAND SECURITY ELEVATION CERTIFICATE OMB No.1660-coos Federal Emergency Management Agency I Excilres February 28. 2009 National Flood Insurance Program important: Read the Instructions on pages 1-8. 5 - PROPERTY INFORMATION :For Igsurance_Gbrtpanq Use;` Al. Building Owner's Name St lecraft Builders - <`• A2- Building StreetAddness (including Apt, Unit Suite. and/or Bldg. No.) or P.O. Route and Box No. 2321 Car,sbrooke Loop City State ZIP Code College Station Texas 77B40 _ A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.) Castiegate, Section 13, Lot 4, Block 1 A4. Building Use (e.g.. Residential, Nori-Residential, Addition, Accessory, etc.) Residence A5. Latitude/Longitude: Lan N 30-W850- Long W 96216.956" Horizontal Datum: Q NAD 1927 0 NAD 1983 AS- Attach at least 2 photographs of the budding if the Certificate is being used to obtain flood Insurance. A7. Building Diagram Number 1---_ A8. For a building with a crawl space or anclosure(s), provide: A9. For a building with an attached garage, provide: a) Square footage of crawl space or enclosure(s) sq ft a) Square footage of attached garage sq ft b) No. of permanent fiord openings in the crawl space or b) No. of pemnanent flood openings in the attached garage enclosure(s) walls wiihin 1.0 foot above adjacent grade walls within 1.0foot above adjacent grade c) Total net area of flood openings in AS.b sq in c) Total net area of flood openings in A9.b sq in SECTION B - FLOOD INSURANCE RATE MAP (FIRM) INFORMATION 81. NF1P Community Name 8 Community Number B2. County Name B3. State Coliegie Station 480083 Brazos I Texas B4. Map/Panel Number 135. Suffix B6. FIRM Index B7. FIRM Panel B8. Rood B9. Base good Elevation(s) (Zone Date I Eft ectivelRevlsed Date Zone(s) AO, use base flood depth) CO205 48041 D 72-92 2-9-2000 AE 306.5 B10. Indicate the source of the Base Hood Elevation (BFE) data or base flood depth entered in Item B9. [] FIS Profile NFIRM1 ❑ Community Determined [] Other (Describe) 1311. Indicate elevation datum used for BFE In Item B9: ❑ NGVD 1929 NAVD 1988 []Other (Describe) B12. Is the budding located in a Coastal Barrier Resources System (CSRS) area or Otherwise Protected Area (OPA)? [� Yes No Designation Date ❑ CBRS 0.OPA SECTION C - BUILDING ELEVATION INFORMATION (SURVEY REQUIRED) Cl. Building elevations are based on: ❑ Constructim Drawings- 0 BwWng Under Construction' Finished Construction "A new Elevation Certificate will be required when conshuction of the bur%rng is complete. C2- Elevations -Zones At-A30, AE, AH. A (with BFE), VE V1430, V (with BFE), AR, AR/A, AR/AE, AR/A1-A30, ARIAH, AR/AO- Complete Items C2-a-9 below according to the building diagram specified in [tern A7. Benchmark Utilized CS 137 (City of College Station) Vertical -Datum NAD 88 Conversion/Comments Subdivision BM a) Top of bottom floor (including basement, crawl space, or enclosure floor) b) Top of the next higher floor c) Bottom of the lowest horizontal structural member (V Zones only) d) Attached garage (top of slab) e) Lowesielevation o€ machineryor equipment seniicing the building ---fQescrrbe'type"afequpmentfnC-nniients)._. -.--- ..-. - -- -- f) Lowest adjacent (finished) grade (LAG) g) Highest adjacent (finished) grade (HAG) Check the measurement used: 308.42 0 feet 0-meters (Puerto Rico only) _-0 feet ❑ meters (Puerto Rico only) _❑ feet ❑ meters (Puerto Rico only) _ n feet ❑ meters (Puerto Rico only) 0 feet meter (Puerto Rico only) 305.22A feet Q meters (Puerto Rico only) 208.03-A feet I] meters (Puerto Rico only) SECTION D -SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION This certification Is to be signed and seated by a land surveyor, engineer, or architect authorized by law to certify elevatiori information. 1 c&rMV-VW the Wwmatian on this Certificate represents my best efforts to iriftpret the data avaAable. ;`S . y •. '.;.g I understand Brat ariy false statement maybe punishable by fine or imprisonment under 18 U.S Code, Section 1001. ❑ C heck here if comments are proyfded on back of form. Certifiers Name- Number Paul Williams 5743 ..s Title Company Names` Surveyor Paul Williams Land Surveying Co. - ; { �� •'�� 5 ,"c�'r FEMA Form 81-31, February 2006 See reverse side for continuation. Repjaces all previous editions I .I y I 4 1 FRONT ELEVATION A SCALE: 3116'=1'-0' I SHEET INDEX COVER SHEET G-1 SITE PLAN C-1 FLATWORK DETAILS C-2 FOUNDATION PLAN S-1 DIMENSION PLAN S-2 FRAMING PLAN S-3 ROOF FRAMING PLAN S-4 DECKING LAYOUT S-5 FRAMING DETAILS S-6 FLOOR PLAN A-1 DETAILS A-2 ELEVATIONS A-3 CABINET LAYOUT A-4 FLOORING PLAN A-5 ELECTRICAL PLAN E-1 SHEEP: G-4 AREA SUMMARY r- 00 00 U � O O 2321 CARISBROOKE LOOP CASTLEGATE L� LOT-4 U BLOCK - 1 SECTION - 13 N W I� a cn ki FINISHING NOTES 3. 4. 5. 6. i ENCE W/ T-41 M • w � cDlu oV N1�1 CD zI TO SA B e 16' ONC. ELIT EE 2321 CARISBROOKE LOOP CASTLEGATE LOT-4 BLOCK-1 SECTION - 13 `1 60L� 4p,s -�, f;e 307• i �GV 0.T,'0pJ V SHEET. c-1 AREA S CRY 00 �1/ N 00 a v� O O A z pp ~'I a - V a o U _ N ao N Ems-+ �.p n 1 SITE PLAN SCALE: 1-=20'-0° BUILDING PERMIT -1CITY OF COAL' STATION ' 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: ' ,979) 764-3570 FAX: (979) 764-3496 ---------------------------------------'------------------------------------- Application Number . . . . Property Address . . . . . Property ID: R. # : Application type description Subdivision Name . . . . . Property Use . . . . . . . Property Zoning . . . . . . Application valuation . . . 06-00003640 Date 12/08/06 2321 CARISBROOKE LOOP 184200-0131-0040 R115968 RESIDENTIAL, 1 UNIT DETACHED NEW CASTLEGATE SEC 10,11,12,13 RESIDENTIAL PLANNED DEVL HOUSING 123486 Owner Contractor STYLECRAFT BUILDERS INC STYLECRAFT BUILDERS ATTN: RANDY FRENCH 4090 SH 6 S 4112 SH 6 S COLLEGE STATION TX 77845 COLLEGE STATION TX 778458964 (979) 690-1222 --- Structure Information 000 000 SINGLE FAMILY Construction Type COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE MASONRY IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1871.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.50 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC TAZ 441.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . NC Permit Fee . . . . 532.00 Plan Check Fee .00 Issue Date . . . . 12/08/06 Valuation . . . . 123486 Expiration Date . . 6/06/07 Qty Unit Charge Per Extension BASE FEE 460.00 24.00 3.0000 THOU BLDG, VAL 100001-500000 72.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) -------------------------------------------- ------ BUILDING DEPT REPRESENTATIVE: --'----------- APPLI BUILDING PERMIT CITY OF COLLEGE'STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 2 Application Number . . . . . 06-00003640 Date 12/08/06 ---------------------------------------------------------------------------- Special Notes and Comments PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8" side & 16" front) For Openings >6 sq. ft. (12" side & 20" front) ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12' ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INS ECTION PROCESS.HAS ---------------------------------------- ----- ----- ------------- EUILDING DErT�REtRESENTATIVE. AP P L I CANT : CJ'_ ' BUILDING PERMIT iCITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 3 Application Number 06-00003640 Date 12/08/06 ---------------------------------------------------------------------------- Special Notes and Comments BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE For residential applications with a glazing area that exceeds 150 of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. STAIRS SHALL COMPLY WITH SECTION R-311 (2003 IRC) WITH A CONTINUOUS HANDRAIL OR SECTION ---- ------------------ -- ------ --- ------------ BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE' STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 4 Application Number 06-00003640 Date 12/08/06 ---------------------------------------------------------------------------- Special Notes and Comments 1009 (2003 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003 IRC) RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 181! ABOVE THE FLOOR IN PRIVATE GARAGES Minimum finished floor 307.50' elevation certificate required ELEVATION CERTIFICATE REQUIRED - PROVIDE ELEVATION CERTIFICATE PRIOR TO SLAB INSPECTION AND A SECOND CERTIFICATE PRIOR TO FINAL INSPECTION/C.O. Narrow Wall Bracing Fully Sheathed with 18" APA Garage Framing ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ---------------------------------------- ----------------- Permit Fee Total 532.00 532.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1282.00 1282:00 .00 .00 ---------------------------------------- ----- - ---------- BUILDING DEPT REPRESENTATIVE: APPLICANT TEMPORARY POLE PERMIT i 'CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number 06-00003641 Date 12/08/06 Property Address . . . . . . 2321 CARISBROOKE LOOP Property ID:. 184200-0131-0040 R #: R115968 Application type description TEMP POLE Subdivision Name . . . . . . CASTLEGATE SEC 10,11,12,13 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation 0. Owner Contractor STYLECRAFT BUILDERS INC STYLECRAFT BUILDERS ATTN: RANDY FRENCH 4090 SH 6 S 4112 SH 6 S COLLEGE STATION TX 77845 COLLEGE STATION TX 778458964 (979) 690-1222 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . NC Permit Fes . . . . 20.00 Issue Date . . . . 12/08/06 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary Charged ---------- Paid Credited ------------------------------ Due ----------------- . Permit Fee Total 20.00 20.00 .00 .00 .'Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 ------------------------------------------- ----4060046WG DEPT REPRESENTATIVE: APPLICANT: For omw use only APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 CrI'YOF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX Pl=dngc-DnxlapmrntServuar WWW CSTX.GOV DATE: I, I lale^^ TRCC REG APPLICATION # TEMP POLE # i ADDRESS/LOCATION: 2 3 2 C>AcR� S�3p0 ILA l—OOP `/ LOT A— /BLOCK SUBDIVISIONSEC/PH 3 ' BUSINESS/OWNER NAME: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120 CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120 CONTRACTOR ADDRESS: 4090 State Highway 6 South ELECTRICIAN: Brazos Valley Electric PLUMBER: Bass Plumbina HVAC: Control Tema GOOD CENTS (Residentinl )y No CLASS OF WORK s ACCESSORY/STORAGE LOCATION jam• R - A D I D T ON DEMOLITION (Asbestos Survey) �'j�i"�✓, DUPLEX (Landscape Plans Required) '``IDESCRIPTION OF WORK: Cor MOVING X NEW CONSTRUCTION REMODEURENOVATION* STRUCTURE USE: Single Family Residence HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: N ,4 TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ N/A VALUATION: $ 12 TOTAL AREA: Z3I HEATED AREA: l 7 I ej (Cost of Labor and Materials) .!�► " DX PUBLIC SEWER NUMBER OF BEDROOMS: SEPTIC/TREATMENT SYSTEM SEWER TAP: F -1 WATER TAP: ` OTHER TAP: X TEMP POLE 16 GARAGE TYPE: NUMBER OF BATHROOMS: 2- ! 2 4° INTERIOR WALL TYPE: Sheet Rock SIZE %° EXTERIOR WALL TYPE: Siding and/or Masonry SIZE FOUNDATION TYPE: Slab on Grade SIZE ROOF TYPE: Composition SINGLE DOUBLE 0 TRIPLE a ATTACHED X� DETACHED F--j CARPORT SIGNATURE OF APPLICANT: • t- 9 b-41�For Stylecraft *If proposed work involves new commercial C#nstruction or facade improvements/renovations to an existing commercial property, building elevations are required. Official Use Only /2- -ob �1�Plans Exa iner 1j3G � i� � Oaea!'�vl vf,� iz5f.1-W vi-y ,Gutqments. (YES or NO Zoning Official 5k4ijtd w�1�" �G � Im Energy Code Compliance Information % Glazing of exterior walls % Insulation R value of exterior walls R13 Insulation R value of ceiling 1 (flat areas): R30 Insulation R value of ceiling 2 (vaulted areas/no attic) R19 Glazing SHGC .40 Glazing U-Factor ; ;-> .65 R value -of ductwor R6 A/C SEER,-&jjgg(b 13 PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# y�� _ DATE: 7-'0 6 BUILDING ADDRESS: ;23X) It62yc��C-e I. Foundation Requirements NA/flKj A. Concrete minimum f c of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier 6 mil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior unless over 60' Ion 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated NA(OK) II. Framing: Floor, Wall, Ceiling and Roof Requirements N A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex K 1. One -hour rated extending to roof deck OK E. Header sizes indicated on plans F. Emergency bedroom egress 1. Exit direct to outside 2. O enable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. O enable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Exterior wall covering indicated on plans 2. Sheathing indicated on plans 3. Moisture barrier indicated on plans J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size and spacing and purlin bracing indicated. O. Roof covering used. P. Indicate Wall Bracing Used for Lateral Bracing PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX 11. Framing: Floor, Wall, Ceiling and Roof Requirements continued N P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations S. 18" Overhang allowed on zero lot line construction, perforated soffit allowed. T. Protected openings on walls < three feet from property line OK III. Stairway Requirements N A. Stairway Details 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" diff. max. 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8 B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches above handrail 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located four or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairwa 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four (4) inch sphere IV. Fireplace Requirements to be indicated onplans) NA/ A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must extend at least three (3) feet higher than the highest point where it projects through the roof of a building & at least two (2) feet higher than any portion of the building within ten (10) feet horizontal PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX V. Electrical Service Requirements N A. Electrical plan to include: 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location VI. Plumbing Requirements NAMW A. Pressure reducing valve required when water pressure exceeds 80 psi B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) VIII. Energy Requirements N A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 N O Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements NA/ K Maximum drive width for residence is 25' combined for circular 12' minimum Minimum 20 feet from driveway to side(intersecting) street Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 NMOK) Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 N Does not block any water course or divert any flow Elevation certificate needed fiVOK ­0 r; ANS EXAMINER DATE REScheck Software Version 3.7.3 Compliance Certificate Project Title: Plan # 1604-1908 FA Report Date: 11/20/06 Data filename: S:WCADWrchived\Old REScheck\1604-1871_2321 Carisbrooke.rck Energy Code: 2000 IECC Location: College Station, Texas Construction Type: Single Family Glazing Area Percentage: 11% Heating Degree Days: 1788 Construction Site: Permit Date: 11/22/2006 Owner/Agent: Designer/Contractor: Permit # Permit Date Compliance: Passes Maximum UA: 7042 0 Your Home UA: 568a19T:S/. e_tte_r Than CodeT(UA)] Maximum SHGC: 0.40 -0 Assembly Gross Area or, Perimeter, Cavity R-Value Cont. R-Value Glazing or Door U-Factor OA Ceiling 1: Flat Ceiling or Scissor Truss: Ceiling 2: Cathedral Ceiling (no attic): Wall 1: Wood Frame, 16" o.c.: Window 1: Metal Frame, Double Pane with Low-E: SHGC: 0.40 Door 1: Solid: Door 2: Glass: SHGC: 0.40 Floor 1: All -Wood Joist/Truss, Over Unconditioned Space: Floor 2: Unheated: , Insulation Depth: 0.0' Air Conditioner 2: Electric Central Air: 13 SEER Furnace 2: Forced Hot Air: 80 AFUE 1026 30.0 0.0 36 143 19.0 0.0 7 2231 13.0 0.0 159 230 0.670 154 38 0.500 19 18 0.580 10 404 14.0 0.0 24 153 0.0 159 Compliance Statement. The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in REScheck Version 3.7.3 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. STy L E G i-A FT '3U I L- PF—IzS, I t 4 G. i I 2 200 Builder/Desig r Company Name Date Project Notes: Previously saved project information: Spec 2321 Carisbrooke Loop College Station, Texas Stylecraft Builders, Inc. 4090 St. Hwy. 6 S. College Station, Texas 77845 Plan # 1604-1908 FA Page 1 of 1