HomeMy WebLinkAboutRES2006-03584, 06-3585ou
33�'8
PREPARED 4/13/07, 11:46:55 INSPECTION TICKET PAGE 6
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 4/13/07
------------------------------------------------------------------------------------------------
ADDRESS . : 141 WALCOURT LOOP SUBDIV: EDELWEISS GARTENS PH 9
CONTRACTOR CHARLES THOMAS HOMES, INC PHONE (979) 696-4384
OWNER EDELWEISS GARTEN VENTURE PHONE
PARCEL 244030-0928-0110
APPL NUMBER: 06-00003584 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 12/21/06 OC BLDG, FOUNDATION -SLAB TIME: 17:00
12/21/06 AP December 21, 2006 8:49:47 AM ncochran.
LATE AFTERNOON
Strings On Setbacks O.K.
Slab Ground Installed
B115 01 1/22/07 OC BLDG, FRAMING TIME: 17:00
1/22/07 AP January 19, 2007 3:36:30 PM glsouth.
B130 01 1/23/07 BH BLDG, INSULATION TIME: 17:00
1/23/07 AP January 23, 2007 4:10:11 PM ncochran.
January 23, 2007 4:10:38 PM ncochran.
B125 01 4/13/0 BI BLDG, FINAL TIME: 17:00
April 13, 2007 9:21:49 AM kwolfe.
------ -------------------------------
COMMENTS AND NOTES --------------------------------------
v /
9
(5/1/2007) Kim Wolfe - Re: Fwd: Calling for CO @ 141 Walcourt Loop Page 1
From: Terry Boriskie
To: Benjamin McCarty; Chris Haver; Gina Southerland; Joe Garcia; Kim Wol...
Date: 5/1/2007 2:55 PM
Subject: Re: Fwd: Calling for CO @ 141 Walcourt Loop
Contacted Charles Thomas at 229-0064 about needed repairs.
Terry Boriskie
City of College Station
Residential Plans Examiner
979-764-3744
>>> Mitchell Carson 4/27/2007 8:38 am >>>
THE SEWER BOX IS BURIED AND NEEDS TO BE RAISED.PLASED A GREEN FLAG AT THE LOCATION.... MITCH
>>> Kim Wolfe 04/24/07 2:05 PM >>>
I am sending this one again, never got a response.
Thanks
Date: 4/13/2007
Inspection Comments for Finals
Permit Year: 6 Permit Number: 3584
Address: 141 WALCOURT LOOP
Insp.
Inspection Type Code
Status
Inspection Result Comments
Description
B100
BLDG, FOUNDATION -SLAB
IC
Strings On Setbacks O.K.
B100
BLDG, FOUNDATION -SLAB
IC
Slab Ground Installed
B130
BLDG, INSULATION
IC
January 23, 2007 4:10:38 PM ncochran.
Page 1
Nicole Cochran - Insulation request inspection result, 141 Walcourt, #06-3584 1
From: Brian Henry '
To: Southerland, Gina
Date: 1/23/2007 3:46 pm
Subject: Insulation request inspection result, 141 Walcou , #06-3584
CC: Cochran, Nicole; Wolfe, Kim
Print for file
Inspected insulation, 141 Walcourt, #06-3584, Thomas Homes, 1-23-07
INspection result: Inspected OK for Good Cents
WF0853797 / 001 City of College Station
PAGE 1
REQ. DATE:
12/04/06
12/04/06
11:04:40
LOCATION:
141 WALCOURT LOOP
LOC ID:
203598
REQUESTOR:
CHARLES THOMAS HOMES, INC ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER: KWOLFE
WORK TYPE:
ROUT
TEMP POLE
PASSED
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT SET
READY
SCHED START:
12/04/06 SCHED COMPLETION:
12/04/06
********************************************************************************
JOB ORDER RESULT COMMENTS
WF0853669 / 001 City of College Station
PAGE 1
REQ. DATE:
12/01/06
12/01/06
16:39:09
LOCATION:
141 WALCOURT LOOP
LOC ID:
203598
REQUESTOR:
CHARLES THOMAS HOMES
ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
GLSOUTH AUTH. USER:
GLSOUTH
WORK TYPE:
ROUT
SWR 4"
WTR 3/41f
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT
SET
READY
SCHED START:
12/01/06 SCHED
COMPLETION:
12/01/06
********************************************************************************
JOB ORDER RESULT COMMENTS
City of College Station
1101 TEXAS AVENUE
COLLEGE STATION TX 77840
C E
R
T
I
F
I
C A T E
O F
O C
C
U
P
A
N
C Y
P E R M
A N E
N T
Issue Date . . . . . .
Parcel Number . . . . .
Property Address . . .
Subdivision Name . . .
Legal Description . . .
Property Zoning . . . .
Owner . . . . . . . . .
Contractor . . . . . .
5/01/07
244030-0928-0110
141 WALCOURT LOOP
COLLEGE STATION TX 77845
EDELWEISS GARTENS PH 9
EDELWEISS GARTENS #9, BLOCK 28
LOT 11
SINGLE FAMILY RESIDENTIAL
EDELWEISS GARTEN VENTURE
CHARLES THOMAS HOMES, INC
979 696-4384
Application number 06-00003584 000 000
Description of Work RESIDENTIAL, 1 UNIT DETACHED NEW
Construction type . . . COMBUSTIBLE (UNPROTECTED)
Occupancy type . . . . RESIDENTIAL-SFR/DUPLEX
Flood Zone . . • • -
Approved
Building Official
VOID UNLESS SIGNED BY.BUILDING OFFICIAL
BUILDING PERMIT
CITY OF CQ,1!,E(E STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 06-00003584 Date 12/01/06
Property Address . . . . . . 141 WALCOURT LOOP
Property ID: 244030-0928-0110
R #: R303281
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . EDELWEISS GARTENS PH 9
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 115000
Owner Contractor
------------------------ ------------------------
EDELWEISS GARTEN VENTURE CHARLES THOMAS HOMES, INC
311 CECILIA LOOP P.O. BOX 10106
COLLEGE STATION TX 778456310 COLLEGE STATION TX 77842
(979) 696-4384
--- Structure Information 000 000 SINGLE FAMILY
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info . . . . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 1657.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 2.00
NUMBER OF BEDROOMS 3.00
SEWER TYPE PUBLIC
TAZ 405.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . . GS
Permit Fee . . . . 505.00 Plan Check Fee .00
Issue Date . . . . 12/01/06 Valuation . . . . 115000
Expiration Date . . 5/30/07
Qty Unit Charge Per Extension
BASE FEE 460.00
15.00 3.0000 THOU BLDG, VAL 100001-500000 45.00
------------I---------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
G'%�p jl �,as�-
------------------------------------------- ---- ------------
BUILDING DEV�RdPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF GOLL•EOE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 06-00003584
Page 2
Date 12/01/06
Special Notes and Comments
X 30") WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
.TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK DONE N�OORRDER_TO
------------------------------------------- --- - -
ais.a=------------
BUILDING DEP� RE�SENTATIVE: '
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 FAX: (979) 764-3496
Application Number
06-00003584
Page 3
Date 12/01/06
Special Notes and Comments
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
Add detectors outside of bedrooms per plans.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
----------------------------------------- - - ------------
BUILDING DEP�RE RE,SENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 4
Application Number . . . . . 06-00003584 Date 12/01/06
----------------------------------------------------------------------------
Special Notes and Comments
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
Narrow Wall Bracing Fully Sheathed with additional anchors
and bracing added per plans.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4" 350.00
WATER TAP 3/4" 400.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
---------------------------------------------------------
Permit Fee Total 505.00 505.00 .00 .00
Plan Check Total .00 .00 .00 .00
Other Fee Total 750.00 750.00 .00 .00
Grand Total 1255.00 1255.00 .00 .00
BUILDING DEPT REIMESENTATIVE:
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
06-00003585 Date 12/01/06
Property Address
. . . . . .
141 WALCOURT LOOP
Property ID:
244030-0928-0110
Application type
description
TEMP POLE
Subdivision Name
. . . . . .
EDELWEISS GARTENS PH 9
Property Use . .
. . . . . .
RESIDENTIAL
Property Zoning .
. . . . . .
SINGLE FAMILY RESIDENTIAL
Application valuation . . . .
0
Owner
Contractor
------------------------
EDELWEISS GARTEN
VENTURE
------------------------
CHARLES THOMAS HOMES,
INC
311 CECILIA LOOP
P.O. BOX 10106
COLLEGE STATION
TX 778456310
COLLEGE STATION
TX 77842
(979) 696-4384
----------------------------------------------------------------------------
Permit . . . . .
. TEMP POLE
PERMIT
Additional desc .
. GS
Permit Fee . . .
. 20.00
Issue Date . . .
. 12/01/06
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary
Charged
----- - ----
Paid Credited
---------- ---------- ----------
Due
-----------------
Permit Fee Total
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
-------------------
BUILDING DE
APPLICANT:
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 7643496 FAX
WWW.CI.COLLEGE-STATION TX.0
Far lomoe-vae-onlly
DATE4D I Z I [ke-C. low
APPLICATION # --b ( — '➢') A
TEMP POLE # 0(/ -5 5 65
Ivc
ADDRESS7BLOCK
ATION: Wq 1coua L22(2
LOT C.;2 U 'SUBDIVISION E d W ASS �-) r �N
& SE /PH
BUSINESS/OWNER NAME: PHONE:
CONTRACTOR/HOMEOWNER:. CHARLES THOMAS HOMES, INC. PHONE: cr�•� 9- OO�p
_CONTRACTOR ADDRESS: f-- COLLEGE STATION, TX 77842
ELECTIFICTetC, PLUMBER: cJ. 6 biAla
HVAC: t/Q �r' GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION OVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION " SLAB ONLY
DUPLEX (Landscape Plans REMODEURENOVATION• SWIMMING POOL
Required)
DESCRIPTION OF WORK:
Aim
STRUCTURE USE: F� '� am /��sJENS !i
�t,6', HOMEOWNER ASSOCIATION- RCHI CTUAL OR DESIGN IIEVIEW COMMITTEE APPROVAL: £S-
TEXAS ACCESSIBILITY STANDARD (TAS) OJECT REGISTRATION# EABPRJ
E/" o -VALUATION: $ 00TOTAL AREA:. J-19-9 3 HEATED AREA:
f . (Cost of Lab r and Materials)
�f PUBLIC SEWER NUMBER OF BEDROOMS:
SEPTIC/TREATMENT SYST M NUMBER OF BATHROOMS:
w
t SEWER TAP: 'INTERIOR WALL TYPE: di�l�rj�Til�
IZ ✓WATER TAP: -3 1 q EXTERIOR WALL -TYPE:
SIZE
OTHER TAP: FOUNDATION TYPE: Qi b
SIZE ON
TEMP POLE ROOF TYPE: DdL� � i T
GARAGE TYPE: SINGLE OUBLE TRIPLE
ATTACHED Ej��DETACHED a CARPORT
1- a
SIGNATURE OF APPLICANT:
'If proposed work involves new commercial construction or facade ' provements/renovations to an existing
commercial property, building elevations are required.
Official Use Only
`0 s
ents:
E rNO
Energy Code Compliance Information
% Glazing of exterior walls
CP�7 �`� ✓ ����,
Insulation R value of exterior walls
Insulation R value of ceiling 1(flat areas)
Insulation R value of ceiling-2 (vaulted areastno attic
Glazing SHGC
Glazing U-Factor
v
R value of ductwork
P I
A/C SEER rating
/
l4
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# _ s F5ATE:
BUILDING ADDRESS:
/y l Lt/ / c o vg,4- L-o vjo
I. Foundation Requirements
NAfM
A.
Concrete minimum fc of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier 6 mil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior unless over 60' Ion
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F.
Wood foundation details indicated
K
II. Framing: Floor, Wall, Ceiling and Roof Requirements
N
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
OK
1. One -hour rated extending to roof deck
K
E.
Header sizes indicated on plans
F.
Emergency bedroom egress
1. Exit direct to outside
2. O enable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
O enable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
N.
O.
P.
Span exceeding code tables must be engineered
Rafter size and spacing and purlin bracing indicated.
Roof covering used.
Indicate Wall Bracing Used for Lateral Bracing
47
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
II. Framing: Floor, Wall, Ceiling and Roof Requirements continued
NA/
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
S. 18" Overhang allowed on zero lot line construction, perforated soffit allowed.
T. Protected openings on walls < three feet from property line
NOOK
III. Stairway Requirements
OK
A. Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" diff. max.
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser hei ht less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches above handrail
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located four or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four (4) inch sphere
IV. Fireplace Requirements to be indicated onplans)
N
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must extend at least three (3) feet higher than the highest point where it
projects through the roof of a building & at least two (2) feet higher than any portion of the
building within ten (10) feet horizontal
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
V. Electrical Service Requirements
NAfM
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
VI. Plumbing Requirements
NA/ K
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
N
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N
Maximum drive width for residence is 25' combined for circular 12' minimum
Minimum 20 feet from driveway to side(intersecting) street
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N Ara
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
N
Does not block any water course or divert any flow
Elevation cert'ficate needed
N K
PLANS EXAMINER DATE
MECcheck Compliance Report
2000 IECC
MECcheck Software Version 3.2 Release lb
TITLE: College Station Building Permits
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 11/30/06
DATE OF PLANS: 12/01/2006
PROJECT INFORMATION:
141 Walcourt Loop - Edlws Grtns 9 [16571
COMPANY INFORMATION:
Charles Thomas Homes, Inc.
COMPLIANCE: Passes
Maximum UA = 779
Your Home = 498
36.1%Better Than Code
Ceiling 1: Flat Ceiling or Scissor Truss
Wall 1: Wood Frame, 16" o.c.
Window 1: Metal Frame, Double Pane with Low-E
Door 1: Solid
Door 3: Solid
Door 2: Glass
Slab 1: Unheated, 0.0' insul.
Air Conditioner 1: Electric Central Air, 14 SEER
Furnace 1: Forced Hot Air, 80 AFUE
Permit Number
Checked By/Date
Gross
Glazing
Area or Cavity
Cont.
or Door
Perimeter R-Value
R-Value
U-Factor
UA
1657 0.0
30.0
51
1876 13.0
0.0
133
189
0.350
66
30
0.440
13
17
0.013
0
17
0.440
7
219
0.0
228
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building
plans, specifications, and other calculations submitted with the permit application. The proposed building has
been designed to meet e 2 00 IECC requirements in Ccheck Version 3.2 Release lb.
Builder/Designer ate 12 (> O (e
CHARLES THOMAS HOMES, INC.
P.O. BOX 10106
k:•OLLEGE STATION, TX 77842
..F
Lo+ii;bikx
i 4 oA i Lr-t Loop