INSPECTION TICKET PAGE 11
City of
College Station
INSPECTOR: BUILDING INSPECTOR DATE 6/18/07
------------------------------------------------------------------------------------------------
ADDRESS
:,;,2443 NEWARK CIR
SUBDIV: CASTLEGATE SEC 5 PH 1
CONTRACTOR CLASSIC
CENTURY HOMES PHONE (817) 561-4369
OWNER
GREENS
PRAIRIE INVESTORS LTD PHONE
PARCEL
184200-1502-0040
APPL NUMBER: 06-00003542
RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT:
BLDG 00 BUILDING PERMIT
REQUESTED
INSP
DESCRIPTION
TYP/SQ
COMPLETED
RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01
1/09/07
RH
BLDG, FOUNDATION -SLAB TIME: 17:00
1/09/07
AP
January 8, 2007 3:29:42 PM kwolfe.
O1/09/2007 11:31 AM RH PDA
Clean out loose debris. Slab ground installed, survey on
file.
B115 01
2/20/07
RH
BLDG, FRAMING TIME: 17:00
2/20/07
DP
February 20, 2007 9:53:23 AM glsouth.
02/20/2007 04:20 PM RH PDA
Need APA framing in back right corner and by back door. No
OSB for fireblocking in fireplace chase. Fireblock cavity
at rear of fireplace chase. Anchors at splices. Engineered
beam over notched for valley in front left room. Fully
tape seal all ext. joints, windows and doors.
B115 02
3/23/07
RH
BLDG, FRAMING TIME: 17:00
3/23/07
AP
March 23, 2007 1:17:36 PM ncochran.
03/23/2007 03:03 PM RH PDA
Seal all penetrations into attic. Cut insulation to fit
properly, do not over stuff. Some areas the insulation
was divided in half. Seal all interior wall corners into
attic. DO NOT OVER STUFF, CUT TO FIT PROPERLY.
Reroute wiring in living room wall at back door.
B130 01
3/23/07
RH
BLDG, INSULATION TIME: 17:00
3/23/07
DP
March 22, 2007 1:12:27 PM ncochran.
afternoon
03/23/2007 03:03 PM RH PDA
Seal all penetrations into attic. Cut insulation to fit
properly, do not over stuff. Some areas the insulation was
divided in half. Seal all interior wall corners into
attic. DO NOT OVER STUFF, CUT TO FIT PROPERLY.
B130 02
3/26/07
RH
BLDG, INSULATION TIME: 17:00
3/26/07
DP
March 26, 2007 11:18:25 AM glsouth.
03/26/2007 03:57 PM RH PDA
Did not correct previous notes. Insulation not to proper
thickness in some areas (over front door and some windows]
Seal all interior corners to exterior and attic. Cut
insulation to fit properly.
=0
B1g30 0 3/27/07
JGM
3/27/07
AP
13125 01 6/18/07
BI
i
BLDG, INSULATION TIME: 17:00
March 27, 2007 11:07:01 AM ncochran.
BLDG, FINAL TIME: 17:00
June 18, 2007 8:27:44 AM acarter.
-------------------------------------- COMMENTS AND NOTES ----------------
----------------------
Date: 6/18/2007
Inspection Comments for Finals
Permit Year: 6 Permit Number: 3542
Address: 2443 NEWARK CIR
Insp.
Inspection Type Code
Status
Inspection Result Comments
B100
BLDG, FOUNDATION -SLAB
IC
01/09/2007 11:31 AM RH PDA
B100
BLDG, FOUNDATION -SLAB
IC
Clean out loose debris. Slab ground installed, survey on
B100
BLDG, FOUNDATION -SLAB
IC
file.
B115
BLDG, FRAMING
IC
02/20/2007 04:20 PM RH PDA
B115
BLDG, FRAMING
IC
Need APA framing in back right corner and by back door.
B115
BLDG, FRAMING
IC
OSB for fireblocking in fireplace chase. Fireblock cavity
B115
BLDG, FRAMING
IC
at rear of fireplace chase. Anchors at splices. Engineered
B115
BLDG, FRAMING
IC
beam over notched for valley in front left room. Fully
B115
BLDG, FRAMING
IC
tape seal all ext. joints, windows and doors.
B115
BLDG, FRAMING
IC
03/23/2007 03:03 PM RH PDA
B115
BLDG, FRAMING
IC
Seal all penetrations into attic. Cut insulation to fit
B115
BLDG, FRAMING
IC
properly, do not over stuff. Some areas the insulation
B115
BLDG, FRAMING
IC
was divided in half. Seal all interior wall corners into
B115
BLDG, FRAMING
IC
___atti_c. DO NOT OVER STUFF, CUT TO FIT
B115
BLDG, FRAMING
IC
Reroute wiring in living room wall at back door.
B130
BLDG, INSULATION
IC
03/23/2007 03:03 PM RH PDA
B130
BLDG, INSULATION
IC
Seal all penetrations into attic. Cut insulation to fit
B130
BLDG, INSULATION
IC
properly, do not over stuff. Some areas the insulation was
B130
BLDG, INSULATION
IC
divided in half. Seal all interior wall corners into
B130
BLDG, INSULATION
IC
attic. DO NOT OVER STUFF, CUT TO FIT PROPERLY.
B130
BLDG, INSULATION
IC
03/26/2007 03:57 PM RH PDA
B130
BLDG, INSULATION
IC
Did not correct previous notes. Insulation not to proper
B130
BLDG, INSULATION
IC
thickness in some areas [over front door and some
B130
BLDG, INSULATION
IC
Seal all interior corners to exterior and attic. Cut
B130
BLDG, INSULATION
IC
insulation to fit properly.
E110
ELEC, ROUGH IN
IC
02/08/2007 02:38 PM RH PDA
Ell
ELEC, ROUGH IN
IC
smoke detector in front bedroom needs proper.clearance
M100
MECH, ROUGH IN
IC
February 12, 2007 1:21:06 PM kwolfe.
Page 1
WF0855620 /
001 City of College
Stater
PAGE 1
REQ. DATE:
12/08/06
12/08/06
15:25:57
LOCATION:
2443 NEWARK CIR
LOC ID:
200984
REQUESTOR:
CLASSIC CENTURY HOMES
ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
GLSOUTH AUTH. USER:
GLSOUTH
WORK TYPE:
ROUT
SWR 4"
WTR 3/411
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT
SET
READY
SCHED START:
12/08/06 SCHED
COMPLETION:
12/08/06
********************************************************************************
JOB ORDER RESULT COMMENTS
Facsimile Cover
by Weyerhaeuser
ToW msrlber of P39M � ,
c anw S 3
TO 0
Vi f t S Fmm
V- t Facsimle Number
Facsimfle Number
7 Ce A -� 4 C� to
peparlment
Department
e- �.S VN
ec.���
( comparry
company - Ia �, - L-,--phow �.
Number
Phone Number -Z O . Z3 2 — � Z 3
MESSAGE
83a - q 35 -
dgi- 931- 17-9.Q 0
T'd L986-TS9-012 JLT:ZO LO 02 Jew
TM
loam
by Weyerhaeuser
To: City of College Station
From: Steve Hausner
Strategic Sales Representative
Ref: Microllam beam used for valley member over Bedroom 4/optional study
Address: Classic Century Homes
2443 Newark Cr
Castle Gate Subdivision
Plan 2397
To whom it may concern
This letter is being written in response to questions concerning the adequacy, of`the Microllam®
beam being used in a valley application over the Bedroom 4/optional study area of the home in question.
This beam has been rip cut to a depth of 7-1/4" for a distance of approximately 30" to accommodate the
slope of a tray ceiling in this room. Based on the loads determined from the architectural plans the single
ply 1-3/4"x7-1/4" Microllam beam is not sufficient to support the present loads by code.
My recommendation is to add one additional ply of 1-3/4"x7-1/4" Microllam beam to the current
beam to net a size of 3-1/2"x7-1/4" Microllam, according to the calculation that I have provided, the
maximum unbraced length of this 3-1/2"x7-114" beam is 9' in the horizontal measurement.
NOTE: This letter and calculation is only valid for Trus Joist® Microllam® product, if either ply of the beam
in question is not Microllam® product, this letter and accompanying calculations are not valid, and I
recommend consulting with the manufacturer of that beam product to determine adequacy.
Thank you.
Steve Hausner
ILevel Strategic Sales Representative
9330 Corporate Dr. Suite 206
Selma Texas 78154
Z'd L986-TS9-012 dLT:20 LO 02 Jew
C
a
8:12
ROOF AS SELECTED
8:12
ROOF AS SELECTED
co
0
r,
0
N
0
8' 1 1 /8" PL
8:12
10' 1 1/8" PL
8:12 ROOF PITCH
N
8:12
N i
In
F
911 l /8" P11
1 1/8" PL a N_
is 10' 1 1 /8" PL °O
60
00
NOTE: 1) Foundation anchor bolts at
60" ox. as per 2000IRC
sec. R403.1.6
2) All framing and structural
design to tneet 90 m.p.h. .
wind criteria as per sec.
00
c!�
rry MLN
0
m
cn
_k
TJ-Bsam®6.25*.K)1�!ft
6 2 Pcs of 1 3/4" x 7 1/4" 1.9E Microllam® LVL
U 3 3J2/2007 106308 AM
8e'
Page 1 Engine Version: 6.25.71 THIS PRODUCT MEETS OR EXCEEDS THE SET DESIGN
CONTROLS FOR THE APPLICATION AND LOADS LISTED
Member Slope: 0.12 Roof Slope0A2
Elm
I
n2
e
9'
All dimensions are horizontal.
Product Diagram is Conceptual,
LOADS:
Analysis is for a Header (Flush Beam) Member. Tributary Load Width: 6'
Primary Load Group - Roof (psf): 20.0 Live at 125 % duration, 15.0 Dead
Vertical Loads:
Type Class Live Dead Location Application Comment
Tapered(plf) Roof(1.25) 120.0 To 50.0 90.0 To 38.0 0 To 9' Adds To Tapered load from gable over entry per S.H.
SUPPORTS:
Input Bearing
Vertical Reactions (Ibs) Detail
Other
Width Length
Live/Dead/Uplift/Total
1 Stud wall 3.50" 1.50"
977 / 765 / 0 / 1742 L1: Blocking Custom Blocking
2 Stud wall 3.50" 1.50"
868 / 684 / 0 / 1552 L1: Blocking Custom Blocking
-See TJ SPECIFIER'S / BUILDERS GUIDE for detail(s): L1: Blocking
DESIGN CONTROLS:
Maximum
Design Control Control
Location
Shear (lbs) 1671
1365 6027 Passed (23%)
Lt. end Span 1 under Roof loading
Moment (Ft-Lbs) 3439
3439 8893 Passed (39%)
MID Span 1 under Roof loading
Live Load Defl (in)
0.132 0.289 Passed (1-1785)
MID Span 1 under Roof loading
Total Load Defl (in)
0.236 0.313 Passed (U440)
MID Span 1 under Roof loading
-Deflection Criteria: MINIMUM(LL:U360.TL:U240). Additional checks follow.
-TL:0.313"
-Bracing(Lu): All compression edges (top and bottom) must be braced at 9' o/c unless detailed otherwise. Proper attachment and positioning of lateral
bracing is required to achieve member stability.
-Design assumes adequate continuous lateral support of the compression edge.
ADDITIONAL NOTES:
-IMPORTANT! The analysis presented is output from software developed by Trus Joist (TJ). Allowable product values shown are in accordance with
current TJ materials and code accepted design values. The specific product application, input design loads and stated dimensions have been provided
by others ( ), have not been checked for conformance with the design drawings of the building, and have
not been reviewed by TJ Engineering.
-THIS ANALYSIS FOR TRUS JOIST PRODUCTS ONLY! PRODUCT SUBSTITUTION VOIDS THIS ANALYSIS.
-Allowable Stress Design methodology was used for Building Code IBC analyzing the TJ Distribution product listed above.
-Note: See TJ SPECIFIER'S / BUILDER'S GUIDES for multiple ply connection.
PROJECT INFORMATION:
Copyright ') 2006 by Trus Joist, a Weyerhaeuser Business
HicrollomF is a registered trademark of Trus Joist.
D:\Documents and Settings\mirandr\Desktop\steve.sms
OPERATOR INFORMATION: !!
-< 1 �0 .r kja _e µy' �u e 5 fio�s
�legse C411 M8.
'Z2-4gZ3
S-d L986-TS9-012 dLT:ZO LO 02 JeW
Mar 02 07 08:44a Cch - B/cs 979 690 3823 P•2
C
U d L9BG-199-OTO
dLT:ZO LO 02 Jew
(6/22/2007) Kim Wolfe - Re: Calling for CO @ 2443 Newark Cir Page 1
From: Terry Boriskie
To: Amber Carter; Benjamin McCarty; Chris Haver; fredburris; Gina Southe...
Date: 6/22/2007 2:19 PM
Subject: Re: Calling for CO @ 2443 Newark Cir
Notified Fred Burris with Classic Century Homes at 690-3868 of the needed repairs.
Terry Boriskie
City of College Station
Residential Plans Examiner
979-764-3744
>>> Paul Schoenfeld 6/19/2007 10:20 am >>>
Water ok.
Sewer box and lid missing flagged.
PAUL
>>> Kim Wolfe 6/18/2007 12:17 PM >>>
Any issues?
BP # 06-3542
Thanks
Kimberly Wolfe, CPS
City of College Station
Planning & Development Services
(979)764-3570
www.cstx.aov
70.00'
10' P.U.E
---------------_4-----
--------------I---, 120'BL
a I
ONE STORY
I a
SINGLE. FAMILY
o
Q l
BRICK RESIDENCE
I Q
o
o
ii
PLAN # 2397 _
o
y�
_
I All I 101 All
I I
I I
18' CONC.
DRIVEWAY
I I
25'-0"
�o >1 L
I I
14'-0" o
5' P.U.E
70.00'
2443 NEWARK CIRCLE
LOT 4 BLOCK 2
SECTION 5, PHASE 1
CASTLE GATE
COLLEGE STATION, BRAZOS CO.
TX
Mar 02 07 12: 27p D / _lsy z —9867 P.1
a f g S �J e,, •� We" " x 7 1/4" 1.9E Microllam® LVL
TJ•6eam66.25 Serial Number: 7003001680 2 PCs Of 1 3/4
User: 3 .3r2r200710:53.0 Ah1
pW, � vemj=8.25.71 THIS PRODUCT MEETS OR EXCEEDS THE SET DESIGN
CONTROLS FOR THE APPLICATION AND LOADS LISTED
Member slope: W12 Roof Slope A2
1
2
Ali dimensions are horizontal.
Product Diagram is Conceptual.
LOADS:
Analysis is for a Header (Flush Beam) Member. Tributary Load Width: V
Primary Load Group - Roof (psf): 20.0 Live at 125 % duration, 15.0 Dead
Vertical Loads:
Location Application Comment
Type Class Live Dead
Tapered(pit) Roof(1.25) 120.0 To 50_0 90.0 To 38-Q 0 To 9' Adds To Taperer toad from gable over entry per S.H.
_SUPPORTS:
Input Bearing
Vertical Reactions (Ibs) Detail
Other
Wrdth Length
LivWMead1UPWTQ al
1 Stud wall 3.50" 1.50"
9771765 / 011742 Lt: Stocking Custom BlodLng
2 Stud wall 3.5D" 1.50"
86816841011552 L1: Blocking Custom Blocking
-See TJ SPECIFIER'S / BUILDERS GUIDE for detaii(s): LI: Blocking
DESIGN CONTROLS:
Maximum
Design Control Control
Location
Shear (Ibs) 1671
1365 6027 Passed (230/0)
Lt. end Span 1 under Roof loading
Moment (Ft-Lbs) 3439
3439 8893 Passed (39%)
MID Span i under Roof loading
Live Load Deft (in)
0.132 0.289 Passed (LrM)
MID Span 1 under Roof loading
Total Load Def, ,(n)
0.236 0:313 Passed-(Ll440)
MID Span 1 under Roof loading
-Deflection Criteria: MINIMUM(LL:U360,TL-L/240). Additional checks follow.
-TL0.313"
-Bracing(Lu): All compression edges (top and bottom) must be braced at S o/c untes-, ktc:tcil'.a Qtii� r:'dis2"". Prpp:. _ afta hri�eni G.nd ga��itiki�ing. of lateral
bracing is required to achieve mismbei stability.
-Design assumss adeguatb continuous lateral support of the compression edge.
ADDITIONAL NOTES:
-IMPORTANT! The analysis presented is output from software developed by Trus Joist (TJ). Allowable product values shown are in accordance with
current TJ materials and code accepted design values. The specific product application, input design bads and stated dimensions have been provided
by others ( ), have not been checked for conformance with the design drawings of the building, and have
'.^.t v....:, '--ne .e0 01" TJ E—g.r+aoring.
. T US JOIST PRODUCTS ONLY! PRODUCT SUBSTITUTION VOIDS THIS ANALYSIS.
_e" .�'4 V•_--_. Yn- n Pi �Il., del i,,in i'? .__Ti. i.F:. ....M.
-
OPERATOR NFOP^MATin—M
d V V e.4 via W-c (•c�! �
4
.tic: of lamri +s a reV+seecea^ccaae"Z. of 'Irus�,iuui.
L': ailacum?nay nnu aa�a a::ya �,.r co,.... :.iau• +•�•.-.-.^�
81 1 1181, P1.1
10, L 1/01, P1.1
1, 0 0-
I'l-, I 2FIDOFT 11,111"CH
eNj
IXI
60
0/1
.......
vs.
ad
11'
1 L.i'gl' PIT,
/
8 q .2
AUNP AS SMIECTEl),
1) Founclalimi mnchar bobs al
a, as por 2000 IRC
. ..... . .... ........ .
rN, "- 1
-1 fi-uijniug wxl structum) 21 A'.'
KID w 90
�.�
— — — — — — — — — — — — — — --- — — — — — — --
OEM
3"m mph,
wincl wilona mi per scc.
Feb 26 07 12:02p Tony Medina (972) 875-1398 p.l
ring, LLC
February 26, 2007
City of College Station
0�, 3,SqZ
401 S. CLAY STREET, ENNLS, TX 75119
3 - -01
Ati-I
Subject: Brace Wall Panel Design at 2443 Newark Circle,
College Station, TX
RE: AGTM Job Code: BWPl006041
At the subject address, at the rear elevation, an alternate
(16" wide) brace wall panel design was installed adjacent to
three windows. Since the header span over the window is Y-0",
the 2 X 6 header is acceptable.
The 2 x 6 header is here authorized by the undersigned.
Sincerely
E OF
.. A. G, MED"
A.G:'Z141edina
Registered Professional Engineer
PHONE: 972.878.FNC.R (3"7) • FAX: 972.975.1399 • E-MAIL: infaQWoundationszom
WFO864098 / 001 City of College Station
PAGE 1
REQ. DATE: 01/08/07 O1-,-"� 01/08/07 10:32:37
LOCATION: 2443 NEWARK CIR LOC ID: 200984
REQUESTOR: CLASSIC CENTURY HOMES ORIGIN: CUSTOMER -WALK IN
REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT
TEMP POLE PASSED
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 01/08/07 SCHED COMPLETION: 01/08/07
JOB ORDER RESULT CONIlK 24TS
Dec 12 06 02:37p Cch - B/cs 979 690 3823 p.2
Dec 05 06 04:20p OTIS 3 817-354-1451 p.6
S U R V E Y P L A T
cled
t certify that I hove, thl date, made on on the ground survey of the property
2443 NEWARK CIRL the City of COLLEGE STATION, Texas, descra)ed as
follows:
Lot 4, Block 2, of CASiLEGATE SUBDIVISION SECTIONS, Phase 1, an Addition to the City
of College Station, Brazos County. Texas, according to the Plot thereof recorded in Volume
6192, Page 200. of the Plot Records of Brazos County, Texas.
,%GIMC SUZ Pa 2DD
2L.e'
7S• 14M
VQ1XME 911E
2W our. LINE
VOW11E OEM PM
NOTES:
2. Basis of Bearing - Subjed Plot
3. r.M. - CONTROLLING MONUMENT
-' 7.5' BID- UNE
\VOIUNE 6192, PC, 200
2DO
y� y� y�
*i? � ......:__..
.............. i
Yrlli Price
i2• t•o�.
Liafb t>Odsll:da
�. afl.,,mra A Llw Fla00 afsURLMK RbE M�V9 ta. Raw eaay1yp� b or b too. HA c• WMi1 a $dM fbM Mama Am. POD Loaf ReafD. MW Ob
aa-al-7Da0 aomrtanlp, Pmr Ib faaNa0aD6 D wE�ar.Y IM Y bwYi Ia Ima iL
Thr Od b~ A a YIM. *Nmd WW 0a9r6 Of h F-"tP W 48%- W La' On as W Va,ad --ft. �Il� b ou0 fY �oro�t�, Iw..N. al'4
..bbdh a ON& Om/ OO Of —W. ao Ohm ana d stl O^#b w7 Ls�Md El ar ffo6 fM �,, LpraRlm Aa ryA d 4prmaaanb arm OO �Iw4
a➢ R ado Un bweaa<In d tl4 pa0uy rfa La7li flan YraO�b Lnaa Ra d dwm i�ML m iAns 14aa Ma w Inakvba b a
Wue w sfd pbt 71wM a,r m Mdba �r�ereearraay dMiel� pr P,ph�w Grp a aiern.
116am P. Priee
hafteiwal undvomw H& 3W
&IGBUENA TIERRA GROUP .W 1a.: °6-'N' 90l111FLI T; • coNsuffm • MMff Y"ADon:L L400 SOUTH INDUSTRIAL BOULEVARD SURE 216 (817) 354-1445 SCPM r + w'EULESS. TEXAS 76040 (B17) 354-1451 (F DLi1WN Bf: MAT.
BUILDING PERMIT
CITY OF COLLEGE STAI r'
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number
06-00003542 Date 12/08/06
Property Address . .
. . . . 2443 NEWARK CIR
Property ID:
184200-1502-0040
R #:
R300539
Application type description
RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . .
. . . . CASTLEGATE SEC 5 PH 1
Property Use . . . .
. . . . RESIDENTIAL
Property Zoning . . .
. . . . PLANNED DEVL HOUSING
Application valuation
158202
Owner
Contractor
------------------------
GREENS PRAIRIE INVESTORS
------------------------
LTD CLASSIC CENTURY HOMES
4490 CASTLEGATE DR
5001 HWY 287 S
COLLEGE STATION
TX 778453388 ARLINGTON TEXAS
BURLESON TX 76028
(817) 561-4369
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID PD
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 2397.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 2.00
NUMBER OF BEDROOMS 4.00
SEWER TYPE PUBLIC
TAZ 441.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
GS
Permit Fee . . . .
637.00 Plan Check Fee .00
Issue Date . . . .
12/08/06 Valuation . . . . 158202
Expiration Date . .
6/06/07
Qty Unit Charge
Per Extension
BASE FEE 460.00
59.00 3.0000
THOU BLDG, VAL 100001-500000 177.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS
THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL
BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
--------------
BUILDING DEPT REPRESENTATIVE:
-------------- --------------
4Aqt
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATIOW
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 06-00003542
Page 2
Date 12/08/06
Special Notes and Comments
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleevejbe owthe slab, seal
---------------------------------------- _1-5� ----------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION`
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 06-00003542
Page 3
Date 12/08/06
Special Notes and Comments
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VA E
---------------------------------------------A�-----------
BUILDING DEPT REPRESEI_TATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION`
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page
4
Application Number . . . . .
06-00003542 Date
12/08/06
----------------------------------------------------------------------------
Special Notes and Comments
RANGE/DRYER DUCT MUST COMPLY
WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND
HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS.
CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS
PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION
SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE
IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES
----------------------------------------------------------------------------
Other,Fees . . . . . . . . .
SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary Charged
----------
Paid Credited Due
------------------------------
-----------------
Permit Fee Total 637.00
637.00 .00
.00
Plan Check Total .00
.00 .00
.00
Other Fee Total 750.00
750.00 .00
.00
Grand Total 1387.00
1387.00 .00
.00
----------------------------------------------�J•-A ------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STI;TION'
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
06-00003543 Date
12/08/06
Property Address . . . . . .
2443 NEWARK CIR
Property ID:
184200-1502-0040
R #:
R300539
Application type description
TEMP POLE
Subdivision Name . . . . . .
CASTLEGATE SEC 5 PH 1
Property Use . . . . . . . .
RESIDENTIAL
Property Zoning . . . . . . .
PLANNED DEVL HOUSING
Application valuation
0
Owner
Contractor
------------------------
GREENS PRAIRIE INVESTORS LTD
------------------------
CLASSIC CENTURY HOMES
4490 CASTLEGATE DR
5001 HWY 287 S
COLLEGE STATION TX 778453388
ARLINGTON TEXAS
BURLESON
TX 76028
(817) 561-4369
----------------------------------------------------------------------------
Permit . . . . . . TEMP POLE
PERMIT
Additional desc . . GS
Permit Fee . . . . 20.00
Issue Date . . . . 12/08/06
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . . . . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary Charged
Paid Credited
------------------------------
Due
---------------------------
Permit Fee Total 20.00
20.00 .00
.00
Other Fee Total 45.00
45.00 .00
.00
Grand Total 65.00
65.00 .00
.00
---------------------------------------------- -----
BUILDING DEPT REPRESENTATIVE: