Loading...
HomeMy WebLinkAboutRES2006-03542, 06-3543ono• ou•�rks � PR: ARf=°' 6/18/07, 11:54:30 INSPECTION TICKET PAGE 11 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 6/18/07 ------------------------------------------------------------------------------------------------ ADDRESS :,;,2443 NEWARK CIR SUBDIV: CASTLEGATE SEC 5 PH 1 CONTRACTOR CLASSIC CENTURY HOMES PHONE (817) 561-4369 OWNER GREENS PRAIRIE INVESTORS LTD PHONE PARCEL 184200-1502-0040 APPL NUMBER: 06-00003542 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 1/09/07 RH BLDG, FOUNDATION -SLAB TIME: 17:00 1/09/07 AP January 8, 2007 3:29:42 PM kwolfe. O1/09/2007 11:31 AM RH PDA Clean out loose debris. Slab ground installed, survey on file. B115 01 2/20/07 RH BLDG, FRAMING TIME: 17:00 2/20/07 DP February 20, 2007 9:53:23 AM glsouth. 02/20/2007 04:20 PM RH PDA Need APA framing in back right corner and by back door. No OSB for fireblocking in fireplace chase. Fireblock cavity at rear of fireplace chase. Anchors at splices. Engineered beam over notched for valley in front left room. Fully tape seal all ext. joints, windows and doors. B115 02 3/23/07 RH BLDG, FRAMING TIME: 17:00 3/23/07 AP March 23, 2007 1:17:36 PM ncochran. 03/23/2007 03:03 PM RH PDA Seal all penetrations into attic. Cut insulation to fit properly, do not over stuff. Some areas the insulation was divided in half. Seal all interior wall corners into attic. DO NOT OVER STUFF, CUT TO FIT PROPERLY. Reroute wiring in living room wall at back door. B130 01 3/23/07 RH BLDG, INSULATION TIME: 17:00 3/23/07 DP March 22, 2007 1:12:27 PM ncochran. afternoon 03/23/2007 03:03 PM RH PDA Seal all penetrations into attic. Cut insulation to fit properly, do not over stuff. Some areas the insulation was divided in half. Seal all interior wall corners into attic. DO NOT OVER STUFF, CUT TO FIT PROPERLY. B130 02 3/26/07 RH BLDG, INSULATION TIME: 17:00 3/26/07 DP March 26, 2007 11:18:25 AM glsouth. 03/26/2007 03:57 PM RH PDA Did not correct previous notes. Insulation not to proper thickness in some areas (over front door and some windows] Seal all interior corners to exterior and attic. Cut insulation to fit properly. =0 B1g30 0 3/27/07 JGM 3/27/07 AP 13125 01 6/18/07 BI i BLDG, INSULATION TIME: 17:00 March 27, 2007 11:07:01 AM ncochran. BLDG, FINAL TIME: 17:00 June 18, 2007 8:27:44 AM acarter. -------------------------------------- COMMENTS AND NOTES ---------------- ---------------------- Date: 6/18/2007 Inspection Comments for Finals Permit Year: 6 Permit Number: 3542 Address: 2443 NEWARK CIR Insp. Inspection Type Code Status Inspection Result Comments B100 BLDG, FOUNDATION -SLAB IC 01/09/2007 11:31 AM RH PDA B100 BLDG, FOUNDATION -SLAB IC Clean out loose debris. Slab ground installed, survey on B100 BLDG, FOUNDATION -SLAB IC file. B115 BLDG, FRAMING IC 02/20/2007 04:20 PM RH PDA B115 BLDG, FRAMING IC Need APA framing in back right corner and by back door. B115 BLDG, FRAMING IC OSB for fireblocking in fireplace chase. Fireblock cavity B115 BLDG, FRAMING IC at rear of fireplace chase. Anchors at splices. Engineered B115 BLDG, FRAMING IC beam over notched for valley in front left room. Fully B115 BLDG, FRAMING IC tape seal all ext. joints, windows and doors. B115 BLDG, FRAMING IC 03/23/2007 03:03 PM RH PDA B115 BLDG, FRAMING IC Seal all penetrations into attic. Cut insulation to fit B115 BLDG, FRAMING IC properly, do not over stuff. Some areas the insulation B115 BLDG, FRAMING IC was divided in half. Seal all interior wall corners into B115 BLDG, FRAMING IC ___atti_c. DO NOT OVER STUFF, CUT TO FIT B115 BLDG, FRAMING IC Reroute wiring in living room wall at back door. B130 BLDG, INSULATION IC 03/23/2007 03:03 PM RH PDA B130 BLDG, INSULATION IC Seal all penetrations into attic. Cut insulation to fit B130 BLDG, INSULATION IC properly, do not over stuff. Some areas the insulation was B130 BLDG, INSULATION IC divided in half. Seal all interior wall corners into B130 BLDG, INSULATION IC attic. DO NOT OVER STUFF, CUT TO FIT PROPERLY. B130 BLDG, INSULATION IC 03/26/2007 03:57 PM RH PDA B130 BLDG, INSULATION IC Did not correct previous notes. Insulation not to proper B130 BLDG, INSULATION IC thickness in some areas [over front door and some B130 BLDG, INSULATION IC Seal all interior corners to exterior and attic. Cut B130 BLDG, INSULATION IC insulation to fit properly. E110 ELEC, ROUGH IN IC 02/08/2007 02:38 PM RH PDA Ell ELEC, ROUGH IN IC smoke detector in front bedroom needs proper.clearance M100 MECH, ROUGH IN IC February 12, 2007 1:21:06 PM kwolfe. Page 1 WF0855620 / 001 City of College Stater PAGE 1 REQ. DATE: 12/08/06 12/08/06 15:25:57 LOCATION: 2443 NEWARK CIR LOC ID: 200984 REQUESTOR: CLASSIC CENTURY HOMES ORIGIN: CUSTOMER -WALK IN REQ. USER: GLSOUTH AUTH. USER: GLSOUTH WORK TYPE: ROUT SWR 4" WTR 3/411 ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 12/08/06 SCHED COMPLETION: 12/08/06 ******************************************************************************** JOB ORDER RESULT COMMENTS Facsimile Cover by Weyerhaeuser ToW msrlber of P39M � , c anw S 3 TO 0 Vi f t S Fmm V- t Facsimle Number Facsimfle Number 7 Ce A -� 4 C� to peparlment Department e- �.S VN ec.��� ( comparry company - Ia �, - L-,--phow �. Number Phone Number -Z O . Z3 2 — � Z 3 MESSAGE 83a - q 35 - dgi- 931- 17-9.Q 0 T'd L986-TS9-012 JLT:ZO LO 02 Jew TM loam by Weyerhaeuser To: City of College Station From: Steve Hausner Strategic Sales Representative Ref: Microllam beam used for valley member over Bedroom 4/optional study Address: Classic Century Homes 2443 Newark Cr Castle Gate Subdivision Plan 2397 To whom it may concern This letter is being written in response to questions concerning the adequacy, of`the Microllam® beam being used in a valley application over the Bedroom 4/optional study area of the home in question. This beam has been rip cut to a depth of 7-1/4" for a distance of approximately 30" to accommodate the slope of a tray ceiling in this room. Based on the loads determined from the architectural plans the single ply 1-3/4"x7-1/4" Microllam beam is not sufficient to support the present loads by code. My recommendation is to add one additional ply of 1-3/4"x7-1/4" Microllam beam to the current beam to net a size of 3-1/2"x7-1/4" Microllam, according to the calculation that I have provided, the maximum unbraced length of this 3-1/2"x7-114" beam is 9' in the horizontal measurement. NOTE: This letter and calculation is only valid for Trus Joist® Microllam® product, if either ply of the beam in question is not Microllam® product, this letter and accompanying calculations are not valid, and I recommend consulting with the manufacturer of that beam product to determine adequacy. Thank you. Steve Hausner ILevel Strategic Sales Representative 9330 Corporate Dr. Suite 206 Selma Texas 78154 Z'd L986-TS9-012 dLT:20 LO 02 Jew C a 8:12 ROOF AS SELECTED 8:12 ROOF AS SELECTED co 0 r, 0 N 0 8' 1 1 /8" PL 8:12 10' 1 1/8" PL 8:12 ROOF PITCH N 8:12 N i In F 911 l /8" P11 1 1/8" PL a N_ is 10' 1 1 /8" PL °O 60 00 NOTE: 1) Foundation anchor bolts at 60" ox. as per 2000IRC sec. R403.1.6 2) All framing and structural design to tneet 90 m.p.h. . wind criteria as per sec. 00 c!� rry MLN 0 m cn _k TJ-Bsam®6.25*.K)1�!ft 6 2 Pcs of 1 3/4" x 7 1/4" 1.9E Microllam® LVL U 3 3J2/2007 106308 AM 8e' Page 1 Engine Version: 6.25.71 THIS PRODUCT MEETS OR EXCEEDS THE SET DESIGN CONTROLS FOR THE APPLICATION AND LOADS LISTED Member Slope: 0.12 Roof Slope0A2 Elm I n2 e 9' All dimensions are horizontal. Product Diagram is Conceptual, LOADS: Analysis is for a Header (Flush Beam) Member. Tributary Load Width: 6' Primary Load Group - Roof (psf): 20.0 Live at 125 % duration, 15.0 Dead Vertical Loads: Type Class Live Dead Location Application Comment Tapered(plf) Roof(1.25) 120.0 To 50.0 90.0 To 38.0 0 To 9' Adds To Tapered load from gable over entry per S.H. SUPPORTS: Input Bearing Vertical Reactions (Ibs) Detail Other Width Length Live/Dead/Uplift/Total 1 Stud wall 3.50" 1.50" 977 / 765 / 0 / 1742 L1: Blocking Custom Blocking 2 Stud wall 3.50" 1.50" 868 / 684 / 0 / 1552 L1: Blocking Custom Blocking -See TJ SPECIFIER'S / BUILDERS GUIDE for detail(s): L1: Blocking DESIGN CONTROLS: Maximum Design Control Control Location Shear (lbs) 1671 1365 6027 Passed (23%) Lt. end Span 1 under Roof loading Moment (Ft-Lbs) 3439 3439 8893 Passed (39%) MID Span 1 under Roof loading Live Load Defl (in) 0.132 0.289 Passed (1-1785) MID Span 1 under Roof loading Total Load Defl (in) 0.236 0.313 Passed (U440) MID Span 1 under Roof loading -Deflection Criteria: MINIMUM(LL:U360.TL:U240). Additional checks follow. -TL:0.313" -Bracing(Lu): All compression edges (top and bottom) must be braced at 9' o/c unless detailed otherwise. Proper attachment and positioning of lateral bracing is required to achieve member stability. -Design assumes adequate continuous lateral support of the compression edge. ADDITIONAL NOTES: -IMPORTANT! The analysis presented is output from software developed by Trus Joist (TJ). Allowable product values shown are in accordance with current TJ materials and code accepted design values. The specific product application, input design loads and stated dimensions have been provided by others ( ), have not been checked for conformance with the design drawings of the building, and have not been reviewed by TJ Engineering. -THIS ANALYSIS FOR TRUS JOIST PRODUCTS ONLY! PRODUCT SUBSTITUTION VOIDS THIS ANALYSIS. -Allowable Stress Design methodology was used for Building Code IBC analyzing the TJ Distribution product listed above. -Note: See TJ SPECIFIER'S / BUILDER'S GUIDES for multiple ply connection. PROJECT INFORMATION: Copyright ') 2006 by Trus Joist, a Weyerhaeuser Business HicrollomF is a registered trademark of Trus Joist. D:\Documents and Settings\mirandr\Desktop\steve.sms OPERATOR INFORMATION: !! -< 1 �0 .r kja _e µy' �u e 5 fio�s �legse C411 M8. 'Z2-4gZ3 S-d L986-TS9-012 dLT:ZO LO 02 JeW Mar 02 07 08:44a Cch - B/cs 979 690 3823 P•2 C U d L9BG-199-OTO dLT:ZO LO 02 Jew (6/22/2007) Kim Wolfe - Re: Calling for CO @ 2443 Newark Cir Page 1 From: Terry Boriskie To: Amber Carter; Benjamin McCarty; Chris Haver; fredburris; Gina Southe... Date: 6/22/2007 2:19 PM Subject: Re: Calling for CO @ 2443 Newark Cir Notified Fred Burris with Classic Century Homes at 690-3868 of the needed repairs. Terry Boriskie City of College Station Residential Plans Examiner 979-764-3744 >>> Paul Schoenfeld 6/19/2007 10:20 am >>> Water ok. Sewer box and lid missing flagged. PAUL >>> Kim Wolfe 6/18/2007 12:17 PM >>> Any issues? BP # 06-3542 Thanks Kimberly Wolfe, CPS City of College Station Planning & Development Services (979)764-3570 www.cstx.aov 70.00' 10' P.U.E ---------------_4----- --------------I---, 120'BL a I ONE STORY I a SINGLE. FAMILY o Q l BRICK RESIDENCE I Q o o ii PLAN # 2397 _ o y� _ I All I 101 All I I I I 18' CONC. DRIVEWAY I I 25'-0" �o >1 L I I 14'-0" o 5' P.U.E 70.00' 2443 NEWARK CIRCLE LOT 4 BLOCK 2 SECTION 5, PHASE 1 CASTLE GATE COLLEGE STATION, BRAZOS CO. TX Mar 02 07 12: 27p D / _lsy z —9867 P.1 a f g S �J e,, •� We" " x 7 1/4" 1.9E Microllam® LVL TJ•6eam66.25 Serial Number: 7003001680 2 PCs Of 1 3/4 User: 3 .3r2r200710:53.0 Ah1 pW, � vemj=8.25.71 THIS PRODUCT MEETS OR EXCEEDS THE SET DESIGN CONTROLS FOR THE APPLICATION AND LOADS LISTED Member slope: W12 Roof Slope A2 1 2 Ali dimensions are horizontal. Product Diagram is Conceptual. LOADS: Analysis is for a Header (Flush Beam) Member. Tributary Load Width: V Primary Load Group - Roof (psf): 20.0 Live at 125 % duration, 15.0 Dead Vertical Loads: Location Application Comment Type Class Live Dead Tapered(pit) Roof(1.25) 120.0 To 50_0 90.0 To 38-Q 0 To 9' Adds To Taperer toad from gable over entry per S.H. _SUPPORTS: Input Bearing Vertical Reactions (Ibs) Detail Other Wrdth Length LivWMead1UPWTQ al 1 Stud wall 3.50" 1.50" 9771765 / 011742 Lt: Stocking Custom BlodLng 2 Stud wall 3.5D" 1.50" 86816841011552 L1: Blocking Custom Blocking -See TJ SPECIFIER'S / BUILDERS GUIDE for detaii(s): LI: Blocking DESIGN CONTROLS: Maximum Design Control Control Location Shear (Ibs) 1671 1365 6027 Passed (230/0) Lt. end Span 1 under Roof loading Moment (Ft-Lbs) 3439 3439 8893 Passed (39%) MID Span i under Roof loading Live Load Deft (in) 0.132 0.289 Passed (LrM) MID Span 1 under Roof loading Total Load Def, ,(n) 0.236 0:313 Passed-(Ll440) MID Span 1 under Roof loading -Deflection Criteria: MINIMUM(LL:U360,TL-L/240). Additional checks follow. -TL0.313" -Bracing(Lu): All compression edges (top and bottom) must be braced at S o/c untes-, ktc:tcil'.a Qtii� r:'dis2"". Prpp:. _ afta hri�eni G.nd ga��itiki�ing. of lateral bracing is required to achieve mismbei stability. -Design assumss adeguatb continuous lateral support of the compression edge. ADDITIONAL NOTES: -IMPORTANT! The analysis presented is output from software developed by Trus Joist (TJ). Allowable product values shown are in accordance with current TJ materials and code accepted design values. The specific product application, input design bads and stated dimensions have been provided by others ( ), have not been checked for conformance with the design drawings of the building, and have '.^.t v....:, '--ne .e0 01" TJ E—g.r+aoring. . T US JOIST PRODUCTS ONLY! PRODUCT SUBSTITUTION VOIDS THIS ANALYSIS. _e" .�'4 V•_--_. Yn- n Pi �Il., del i,,in i'? .__Ti. i.F:. ....M. - OPERATOR NFOP^MATin—M d V V e.4 via W-c (•c�! � 4 .tic: of lamri +s a reV+seecea^ccaae"Z. of 'Irus�,iuui. L': ailacum?nay nnu aa�a a::ya �,.r co,.... :.iau• +•�•.-.-.^� 81 1 1181, P1.1 10, L 1/01, P1.1 1, 0 0- I'l-, I 2FIDOFT 11,111"CH eNj IXI 60 0/1 ....... vs. ad 11' 1 L.i'gl' PIT, / 8 q .2 AUNP AS SMIECTEl), 1) Founclalimi mnchar bobs al a, as por 2000 IRC . ..... . .... ........ . rN, "- 1 -1 fi-uijniug wxl structum) 21 A'.' KID w 90 �.� — — — — — — — — — — — — — — --- — — — — — — -- OEM 3"m mph, wincl wilona mi per scc. Feb 26 07 12:02p Tony Medina (972) 875-1398 p.l ring, LLC February 26, 2007 City of College Station 0�, 3,SqZ 401 S. CLAY STREET, ENNLS, TX 75119 3 - -01 Ati-I Subject: Brace Wall Panel Design at 2443 Newark Circle, College Station, TX RE: AGTM Job Code: BWPl006041 At the subject address, at the rear elevation, an alternate (16" wide) brace wall panel design was installed adjacent to three windows. Since the header span over the window is Y-0", the 2 X 6 header is acceptable. The 2 x 6 header is here authorized by the undersigned. Sincerely E OF .. A. G, MED" A.G:'Z141edina Registered Professional Engineer PHONE: 972.878.FNC.R (3"7) • FAX: 972.975.1399 • E-MAIL: infaQWoundationszom WFO864098 / 001 City of College Station PAGE 1 REQ. DATE: 01/08/07 O1-,-"� 01/08/07 10:32:37 LOCATION: 2443 NEWARK CIR LOC ID: 200984 REQUESTOR: CLASSIC CENTURY HOMES ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT TEMP POLE PASSED ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 01/08/07 SCHED COMPLETION: 01/08/07 JOB ORDER RESULT CONIlK 24TS Dec 12 06 02:37p Cch - B/cs 979 690 3823 p.2 Dec 05 06 04:20p OTIS 3 817-354-1451 p.6 S U R V E Y P L A T cled t certify that I hove, thl date, made on on the ground survey of the property 2443 NEWARK CIRL the City of COLLEGE STATION, Texas, descra)ed as follows: Lot 4, Block 2, of CASiLEGATE SUBDIVISION SECTIONS, Phase 1, an Addition to the City of College Station, Brazos County. Texas, according to the Plot thereof recorded in Volume 6192, Page 200. of the Plot Records of Brazos County, Texas. ,%GIMC SUZ Pa 2DD 2L.e' 7S• 14M VQ1XME 911E 2W our. LINE VOW11E OEM PM NOTES: 2. Basis of Bearing - Subjed Plot 3. r.M. - CONTROLLING MONUMENT -' 7.5' BID- UNE \VOIUNE 6192, PC, 200 2DO y� y� y� *i? � ......:__.. .............. i Yrlli Price i2• t•o�. Liafb t>Odsll:da �. afl.,,mra A Llw Fla00 afsURLMK RbE M�V9 ta. Raw eaay1yp� b or b too. HA c• WMi1 a $dM fbM Mama Am. POD Loaf ReafD. MW Ob aa-al-7Da0 aomrtanlp, Pmr Ib faaNa0aD6 D wE�ar.Y IM Y bwYi Ia Ima iL Thr Od b~ A a YIM. *Nmd WW 0a9r6 Of h F-"tP W 48%- W La' On as W Va,ad --ft. �Il� b ou0 fY �oro�t�, Iw..N. al'4 ..bbdh a ON& Om/ OO Of —W. ao Ohm ana d stl O^#b w7 Ls�Md El ar ffo6 fM �,, LpraRlm Aa ryA d 4prmaaanb arm OO �Iw4 a➢ R ado Un bweaa<In d tl4 pa0uy rfa La7li flan YraO�b Lnaa Ra d dwm i�ML m iAns 14aa Ma w Inakvba b a Wue w sfd pbt 71wM a,r m Mdba �r�ereearraay dMiel� pr P,ph�w Grp a aiern. 116am P. Priee hafteiwal undvomw H& 3W &IGBUENA TIERRA GROUP .W 1a.: °6-'N' 90l111FLI T; • coNsuffm • MMff Y"ADon:L L400 SOUTH INDUSTRIAL BOULEVARD SURE 216 (817) 354-1445 SCPM r + w'EULESS. TEXAS 76040 (B17) 354-1451 (F DLi1WN Bf: MAT. BUILDING PERMIT CITY OF COLLEGE STAI r' 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number 06-00003542 Date 12/08/06 Property Address . . . . . . 2443 NEWARK CIR Property ID: 184200-1502-0040 R #: R300539 Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . CASTLEGATE SEC 5 PH 1 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation 158202 Owner Contractor ------------------------ GREENS PRAIRIE INVESTORS ------------------------ LTD CLASSIC CENTURY HOMES 4490 CASTLEGATE DR 5001 HWY 287 S COLLEGE STATION TX 778453388 ARLINGTON TEXAS BURLESON TX 76028 (817) 561-4369 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID PD FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 2397.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC TAZ 441.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . GS Permit Fee . . . . 637.00 Plan Check Fee .00 Issue Date . . . . 12/08/06 Valuation . . . . 158202 Expiration Date . . 6/06/07 Qty Unit Charge Per Extension BASE FEE 460.00 59.00 3.0000 THOU BLDG, VAL 100001-500000 177.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) -------------- BUILDING DEPT REPRESENTATIVE: -------------- -------------- 4Aqt APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATIOW 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 06-00003542 Page 2 Date 12/08/06 Special Notes and Comments PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12' ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleevejbe owthe slab, seal ---------------------------------------- _1-5� ---------- BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION` 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 06-00003542 Page 3 Date 12/08/06 Special Notes and Comments annular space at ends with caulk, foam or other means. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VA E ---------------------------------------------A�----------- BUILDING DEPT REPRESEI_TATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION` 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 4 Application Number . . . . . 06-00003542 Date 12/08/06 ---------------------------------------------------------------------------- Special Notes and Comments RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES ---------------------------------------------------------------------------- Other,Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged ---------- Paid Credited Due ------------------------------ ----------------- Permit Fee Total 637.00 637.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1387.00 1387.00 .00 .00 ----------------------------------------------�J•-A ------------ BUILDING DEPT REPRESENTATIVE: APPLICANT: TEMPORARY POLE PERMIT CITY OF COLLEGE STI;TION' 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 06-00003543 Date 12/08/06 Property Address . . . . . . 2443 NEWARK CIR Property ID: 184200-1502-0040 R #: R300539 Application type description TEMP POLE Subdivision Name . . . . . . CASTLEGATE SEC 5 PH 1 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation 0 Owner Contractor ------------------------ GREENS PRAIRIE INVESTORS LTD ------------------------ CLASSIC CENTURY HOMES 4490 CASTLEGATE DR 5001 HWY 287 S COLLEGE STATION TX 778453388 ARLINGTON TEXAS BURLESON TX 76028 (817) 561-4369 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . GS Permit Fee . . . . 20.00 Issue Date . . . . 12/08/06 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited ------------------------------ Due --------------------------- Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 ---------------------------------------------- ----- BUILDING DEPT REPRESENTATIVE: APPLICANT: 4,�