Loading...
HomeMy WebLinkAboutRES2006-03540, 06-3541Ob•3os'10 Ott�3g41 � 9 I JAN-21-2009 12:55 From:9797744736 To:7643496 Pa9e:2,3 TEXAS SPCB TERMITE TREATMENT" DISCLOSURE DOCUMENT ProRady r: CLASSIC CENTIJRYWOMES ' O Location_t9 be Treated: 2447 NEWARK4M. r ApproxLate Measures to be Treated: 3128 Percentage_of Termticide(sl to,6e app ad, at this location: Q_Q aoavG,ei�� Type of TroAment; Emil ____ Partial _ XX Vertical XX NorizontaUF�®rimeter Beam XX Foundation: SLAB , 'ding;,BRICK — PjrlMaty Use: RESIDENCE Roof: COMPOSITION • • • 1 : . 1 = 4 • f • - 1T.1 : • • :. • it • • It = 1 A I AOEL FOR ANY OTHER PEST ICIDE RECOMENDED OR USED HAS BEEN ATTACHED AS PART OF 1}118 OOCUINNT WARRANTY INFORMATION (IF ANY) INCLUDING, AREA COVERED, TIME PERIOD OF WARRANTY, RENEWAL OPTIONSAND COST, THE 08LICATIONS OF THE PEST CONMOL DPERATpR 70 n- TRCAT FOR TERMITE INFE9YAI'I0148 OR REPAIR DAMAGE CAUSED SY TERbUTE INFESTATIONS WITHIN THE WARRANTY PERIOD, AND THE CONDIT►ON$'I'HAF COULD 09VELOP AS A RESULT OF THE OWNERS ACTION OR INACTION THAT WOULD VOID ME WARRANTY HAS ALSO OEEN ATTACHED. Charges for pre -treat: NOTES: Annual re-newal: $338.61 a 9 a-36q 32129 PT Ca at Tochbwkn SM 11cum 0 1/11/2007 U129 PT Terry Boriskie C%0 Issues From: Terry Boriskie To: fredburris Date: 12/29/2008 12:56 pm Subject: C/O Issues Fred, I am trying to clear up items that have been sitting out there for a while and are simple to get done in order to issue a C/O. The following addresses need Proof of Termite Forms: 2447 Newark 2461 A1ewaf1.TR et�ay- 200 Passendale *2447 Newark also has a Handrail issue on the back patio steps to be resolved. Thanks, Terry Boriskie City of College Station Residential Plans Examiner Ofc.979-764-3744 Fax 979-764-3496 "Home of Texas A&M University" WF0864099 / 001 City of College Station 2 PAGE 1 REQ. DATE: 01/08/07 01/08/07 10:33:54 LOCATION: 2447 NEWARK CIR LOC ID: 200980 REQUESTOR: CLASSIC CENTURY HOMES ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT TEMP POLE PASSED ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 01/08/07 SCHED COMPLETION: 01/08/07 ******************************************************************************** JOB ORDER RESULT COMMENTS Date: 12/8/2008 Inspection Comments for Finah Permit Year: 6 permit Number: 354C Address: 2447 NEWARK CIR Type Inspection Type Code Description status Inspection Result Comments B100 BLDG, FOUNDATION-SL, IC January 16, 2007 10:25:15 AM kwolfe. B100 BLDG, FOUNDATION-SLi IC Fred called and cancelled - will call back in B100 BLDG, FOUNDATION -SLR IC Strings On Setbacks O.K. B100 BLDG, FOUNDATION -SLR IC Slab Ground Installed 13115 BLDG, FRAMING IC 02/27/2007 11:42 AM RH PDA 13115 BLDG, FRAMING IC Need anchors at back door and splices. Add nails to 2x4's 13115 BLDG, FRAMING IC on vaulted ceiling in master and front right bedroom. By 6115 BLDG, FRAMING IC insulation inspection. Page 1 PREPARED 12/08/08, 12:03:20 INSPECTION TICKET PAGE 1 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 12/08/08 ------------------------------------------------------------------------------------------------ ADDRESS 2447 NEWARK CIR SUBDIV: CASTLEGATE SEC 5 PH 1 CONTRACTOR CLASSIC CENTURY HOMES PHONE (817) 561-4369 OWNER GREENS PRAIRIE INVESTORS LTD PHONE PARCEL 184200-1502-0020 APPL NUMBER: 06-00003540 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 1/16/07 BI BLDG, FOUNDATION -SLAB TIME: 17:00 1/16/07 CA January 12, 2007 4:22:03 PM kwolfe. January 16, 2007 10:25:15 AM kwolfe. Fred called and cancelled - will call back in B100 02 1/23/07 JGM BLDG, FOUNDATION -SLAB TIME: 17:00 1/23/07 AP January 23, 2007 11:20:01 AM kwolfe. Strings On Setbacks O.K. Slab Ground Installed B115 01 2/27/07 RH BLDG, FRAMING TIME: 17:00 2/27/07 AE February 26, 2007 4:46:40 PM ncochran. 02/27/2007 11:42 AM RH PDA Need anchors at back door and splices. Add nails to 2x4's.. on vaulted ceiling in master and front right bedroom. By insulation inspection. B130 01 3/02/07 OC BLDG, INSULATION TIME: 17:00 AP March 2, 2007 10:10:30 AM kwolfe. B125 01 12/08/08 BI BLDG, FINAL TIME: 17:00 December 8, 2008 10:51:14 AM ccourt. -------------------------------------- COMMENTS AND NOTES -------------------------------------- C O ��: h+ -1 t o 1 h�-c`c aa`{ 0 Terry Boriskie - 108 Roucourt and 2447 Newark Cir. 1� From: Terry Boriskie To: fredburris Date: 12 10/2008 2:08 pm Subject: W13c and 2447 Newark Cir. a ess ter ite s/47 a s ee s an a ' teps Thanks, Terry Boriskie City of College Station Residential Plans Examiner Ofc. 979-764-3744 Fax 979-764-3496 "Home of Texas A&M University" VN RIv WF0855618 / 001 City of College Station �_ PAGE 1 REQ. DATE: 12/08/06 12/08/06 15:23:28 LOCATION: 2447 NEWARK CIR LOC ID: 200980 REQUESTOR: CLASSIC CENTURY HOMES ORIGIN: CUSTOMER -WALK IN REQ. USER: GLSOUTH AUTH. USER: GLSOUTH WORK TYPE: ROUT SWR 4" WTR 3/411 ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 12/08/06 SCHED COMPLETION: 12/08/06 ******************************************************************************** JOB ORDER RESULT COMMENTS -• APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 Cf"fi'()I'+` f)I.LLc.l S'Ifi't'fC7A' (979) 764-3570 (979) 764-3496 FAX ('Lrnwrt�aL&arlxysm..ca;y�wa WWW.CSTX.GOV DATE: i FRCQ REC+ �j APPLICATION # V lY 1 V OIL_ TEMP POLE # t U — 550 ADDRESS/LOCATION: --Jr1 K— r\� LOT __jI , LOCK _ Z_ SUBDIVISION � G,. L7_ i�T�: __/ SEC/PH . _._,. BUSINESS/OWNER NAME: L.A`- 1� :6 _ _�iAi✓ S PHONE: L-=:a80 CONTRACTOR/HOMEOWNER: CtL-A4 5� � PHONE: ?3 t,��9 CONTRACTOR ADDRESS::IRA 1 l -iwta !� ELECTRICIAN: HVAC: _ GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION " SLAB ONLY DUPLEX (Landscape Plans REMODEURENOVATION- SWIMMING POOL Required) DESCRIPTION OF WORK: ,.J.��y STRUCTURE USE: HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ 1yt/I VA UATrON: S �Io" . _ TOTAL AREA: �3 HEATED AREA: ` 2(,o (cost of Laor and Materials) PUBLIC SEWER SEPTiclTREATMENT SYSTEM !/ 11 SEWER TAP: T 3s Est WATER TAP: SIZE ❑ THER TAP: SIZE TEMP POLE GARAGE TYPE: SINGLE ATTACHED NUMBER OF BEDROOMS: t_ NUMBER OF BATHROOMS: - INTERIOR WALL TYPE.'I�(} EXTERIOR WALL TYPE: FOUNDATION TYPE: ROOF TYPE: DOUBLE TRIPLE DETACHED ❑ CARPORT SIGNATURE OF APPLICANT: ' " '1f proposed work involves new com erci constr 'ion or facade improvements/renovations to an existing commercial property, building elevations are require . �. Official Use Only ments: Ze�-0 YCor NO Plans Examiner Zoning Official 6og 090-col 4 P,i vo(, OA) EEzergy Core Compliance Informadoh °/a Glazing of exterior walls Insulation R value of extenor -walls ! ` Insulation fit. value of ceiling l (flat areas) insulation R value of ceiling 2 (vaulted areas/no attic) `" F>�TT Glazing SHGC Glazing U-Factor value of ductwork R al T_ AJC SEER. Rating . ,L PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# DATE: ��-35 �{� /I-z8 -06 BUILDING ADDRESS: , r cg� % I. Foundation Requirements NA/OK A. Concrete minimum fc of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier 6 mil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior unless over 60' Ion 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated NA/OK II. Framing: Floor, Wall, Ceiling and Roof Requirements NA/OK A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex NA/OK 1. One -hour rated extending to roof deck NA/OK E. Header sizes indicated on plans F. Emergency bedroom egress 1. Exit direct to outside 2. O enable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill hei ht of forty-four 44 inches above finished floor G. O enable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Exterior wall covering indicated on plans 2. Sheathing indicated on plans 3. Moisture barrier indicated on plans J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans M. N. O. P. Span exceeding code tables must be engineered Rafter size and spacing and purlin bracing indicated. Roof covering used. Indicate Wall Bracing Used for Lateral Bracing PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX II. Framing: Floor, Wall, Ceiling and Roof Requirements continued NA/OK P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations S. T. 18" Overhang allowed on zero lot line construction, perforated soffit allowed. Protected openings on walls < three feet from property line NA/OK III. Stairway Requirements NA/OK A. Stairway Details 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" diff. max. 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8 B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches above handrail 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located four or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four (4) inch sphere IV. Fireplace Requirements to be indicated onplans) NA/OK A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must extend at least three (3) feet higher than the highest point where it projects through the roof of a building & at least two (2) feet higher than any portion of the building within ten (10) feet horizontal 1 PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX V. Electrical Service Requirements NA/OK A. Electrical plan to include: 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location VI. Plumbing Requirements NA/OK A. Pressure reducing valve required when water pressure exceeds 80 psi B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements NA/OK A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) VIII. Energy Requirements NA/OK A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 NA/OK Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements NA/OK Maximum drive width for residence is 25' combined for circular 12' minimum Minimum 20 feet from driveway to side(intersecting) street Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 NA/OK Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 NA/OK Does not block any water course or divert any flow Elevation certificate needed NA/OK PLANS EXAMINER DATE 0 Engineering LLC October 11, 2006 Classic Century Homes 5001 Hwy. 287 South Arlington, TX 76017 401 S. CLAY STREET. ENNIS. TX 75119 The following post -tensioned foundation plans are herein authorized for construction at the address and legal description shown below. Lot Blk Subdivision Address c1tv County State 2 2 Castle Gate 2447 Newark Circle College Station Brazos TX A site specific soils report was not provided. The foundation has been designed based on the following soils conditions. Soils Laboratory Brazos County USDA Soils Survey Allowable Bearing Pressure P.I. 1200 psf 36 The foundation design is in accordance with the applicable provisions of the International Building Code 2000/2003 Edition, the International Residential Code 2000/2003 Edition, the Design and Construction of Post - Tensioned Slabs -on -Ground, Second Edition, 1996 by the Post -Tensioned Institute, applicable provisions of the Building Research Advisory Board (GRAB) Publication 33, and accepted engineering practice. If.you have any questions, please call me at 972-878-3647. u PTF1006046 Sincerely, i A.G. (Tony) Medina Registered Professional Engineer PHONE: 972.878.ENGR (3647) - FAX: 972.875.1398 - E-MAIL: info@txfoundations.com 70.00' ------ 10' P.U.E M --------------- r- - - - - - - - - - - - - - - - i ONE STORY SINGLE FAMILY a BRICK RESIDENCE a pq PLAN # 2476 m W W M � 7'-7" 54'-10" 7'-7" i 18' CONC. i DRIVEWAY 25'-0" L- - - - - - - - J 0 14'-0" 0 N '- - -- -- -- 5P.U.E 70.00' 2447 NEWARK CIRCLE LOT 2 BLOCK 2 SECTION 5, _PHASE I CASTLE GATE COLLEGE STATION, BRAZOS CO. TX L L UUUBLb-- ROWLOCK TO SURROUND WINDOWS W/6' x TAR TR AR TR MULLED PLAN # 2476 latsic ADDRESS 2447 NEWARK CR LOT 2 Century BLK 2 Homes SUBDIVISION CASTLE GATE Miliy Haw D.. oAQa laMi LL - W/6'xTAR TR BRICK QUOINS W V PROJECTION NOTE: 1) SHADED WALLS TO 2" x ro" FOR PLUMBING 2) ALL HEADER HEIGHTS TO BE 6'10" UNLESS OTHERWISE NOTED 3) I=ROVlr->E TEMPERED GLASS WHERE NEEDED . 54' 10" I 3- 0" 15- 6" L 3' 0" L 14- 3" L2'6" L 5' 5 1/32" 2' 2" 8' 11 31/32" 3- (r 6-0- L I 3'0-x5'0* 3'Tx6'0* ... .3�'V.50- ---- ------------ ----- ----------- E REkkiiX§t ..... 0-1 ...u... ................................. . -------------------------------- O 3 9" L 3*0*.6'0" TC1.61 8'- IO'CLG KITCHEN C14 MSTR SUITE ENGIce 8'- 10'CLG tia :10'8" 6' 7" 3-8" .... ........ FAMILY ') IO'CLG 2- 10"[ TV 41711 3' 0. PLANT SH @ 8'6" 19.51. 14' 6" DINING I zu co ART EN NICHE PLANT SHELVES @ 8'6' RCH :T v -- 04. BDRM 2 8'CLG ----------- - -- a CD b b 3' 7" 13- 9" b" 7' ;10" 6' 4" 6'9" - - - - - - J T(r LINEN 70' ;X N 6 E IR Y10 00 GAMEROOM zo: CLG 7' 2" - 4-2 re 8'- 10'CLG DRM 41 STUDY BDRM 3 3-1 8'CLG 8'CLG iA re 4' rl. 12-9" N WH iA UTIL. ih .......... AC EBB - ----I I i - F OR SEE ELEvATIONS 1'6'. WINDOWS SIZE AVE) LOCATION GM C"i 5'5" 10.01. 13- 4" 4' 7" co 04 GARAGE 8'CLG FOOTAGE At r- 15'5" 17' 11 c) N b - 04 LIVING 2476 CN GARAGE 512 PORCH 15 TOTAL 3003 PLAN ft 2476 lassie R omq EMN 1 ADDRESS 2447 NEWARK CR Centay LOT 2 13LK 12 S=N I CASTLE GATE 8'0" 13-6" 21- 6" I 33'4" 54' 10" LtIr i tLE V A ION PLAN P 76 Aoaxess 2447 NEWARK CR LOT Centli� aLK H® es �BDOVISION ASTLE GATE NOTE: ALL SIDING TEMPLE HARDBOARD a a 00 00 Its at 00 IRC .ural m.p.h. sec. :301.2(4) to be per ners gale. steel, ....an bronze or coper only as per sec. R323.3 4) Provide hand rails on all stairs/steps with a minimum of 2 risers as per sec. R315. (min. stair tread 10": max- riser 1 3/4" sec. R314.2) 5) Masonry veneer anchorage of 24" horizontal and V vertical as per sec. R1O3.1.4.1 and weep holes at a maximum of 33" o.c. as per sec. R1O3.1.6. -----------------------------------------------------------------------------------------------------------.......................... 8' CLG Q9.......................... BREAKFAST' p �g � � F 8 10 CLG MSTR SUITE 8' 10' CLG N KITCHEN v 3 FAMILY •� 10' CLG '° BLK & WIRE " O FOR FAN ONLY ' B PLANT SHELVES @ 8'6^ i Y G� DIIQING ART PLANT SHELVES @ 8'6" di NICHE BDRM 2 .H 11 8' CLG VL BLKIRE GAMEROOM ,q� FOR FFOR ONLY Y V 8' - 10' CLG :: L=,ENT RY ¢. --_ -- 1Q' CLG " BDRM 4 BLK & WIRE FOR FAN ONLY ' ®BDRM 3 BLK & WIRE 8' CLG 8' CL6 FOR FAN ONLY ........ en .ass GARAGE 8' CLG �r11 PLAN k 2476 ELECTRICAL ADDRESS LOT BLK SUBDIVISION BLK& WIRE FOR FAN ONLY UPLIGHTS ....... '. NOTE: 1) Lighting on stair to conect from switch @ top to light mounted on wall @ middle of stairs to switch @ bottom of stairs per sec R303.4 2) Smoke detectors will be hard wired in series w/ battery backup power as per sec. R317 3) Provide 110 outlet & light near HVAC unit for service with switch. Electrical ALL EXTERIOR LIGHTS Celli Mg fan spotlights I RAN TO TIMER IN GARAGE COACH LIGHTS Iassic Century Homes JWiu It—, e^nr/.A%p w,d N, _n - Kim 11 rluorescent fixture 0 pot light e e o o e vanity bar light ® fan ¢ Ilght outlet �b outlet 220v outlet Sri e smoke detector $ switch $ switch 3 way NE•MIF rn_ Ala a-- F,1s'u.411's.<. lII BAR MSUTAIWN I?OYPSUM BOAaD rx160mou PUTE BAR agUTATNN FUR -v UY FLUUR WEATOIERTROTFU .W, — MErN. aRxxnEs I•AOITY 1?sIMIEATinNU -A- K11—uBAI1 L MSIMiA 1lM ?s11EETROCK M ALBRifK 11F% :'-RAM ?SRFATl11NO AIIJ DARRIER sT TT,.11',. OF. HU M.uunroN ?nRiTRMx .1..-_FE TRF Rl1 RIx.LLRWRSYRrAt: W'ilGSUOTUAR TRlas nARNc ANo nnalo'.ss Tn BE OERRAONED BY ENGMEER INILaKxICDUNO FMLW OF FLOOR Jolt IWELT VEM EVFAY IaD BRIfK AT MWTOM) 4 J ' • "� ALL SLAB Ma1FM5RIN5 TIaCKNFSSB. J � : •1 IRFJNIURCGIEVT'IUtlk DEltiaMalhL BY •� [NGMFFA AT AIR FLOW IS NOT I (OVERRAN SHINGLES a<_ 1/2" PLYWOOD SHEATHING c/W 'H' CLIPS 2"X6' RAFTERS c 24" o.C. BATT INSULATION NUOUS AIR VENT BAFFLES C. ROOF PI' T RIDGE TO BE INSTALLED CTED DECKING MAX. WOOD FASCIA _ �P MIN. CONTI -24' 0. END A 50 TH SOFFIT MATERIAL TYPICAL BRICK EXTERIOR WALL FACE BRICK 1' AIR SPACE in. SHEATHING 2"x4' STUDS o 16" o.c. BATT INSULATION CITY OF LOCKHART 1/2' 5HEETROCK TYPICAL ROOF OVERHANG DETAIL SMGIF4 CTMTMIIDUsuR VENTEWAU3FD 30 OU• R. ENDS AT RiMiE.10 BE iNRAl1iIUT uR ILON'6 NOT RFJIIII('rFD ,nN.lk1 aAREpa B U'OG I?KMOODS TRMO RMOs i rAsfu SO—WIEWALLYSPAMo tM$ @e0.c IYMAL LW BMl%ExrEMOR WALL CK MRAL a :'AIR slACEAfE m IVUU eARRamER A a nTj11 0.f RII )BATT BAR Ms11lATI0N I15IIEtTR04lf METAL IFOCK TIES I•MSPALE Us' naAT g BAR R h. uos m sT1s-•. RU 6AR BdI vrsxEETxocx 100LT4Bo.r MAX. J � ,4 ALLunaonRNSluxsnncKNEcsEc • • .1 IRtlMUO}AOJTr1T1 Bl ULTIlAaNF]1 B1' EITOMEFd TOP VIEW CHIMNEY \CAP V 2X4 BAND I I I I 2X4 FRAM G MEMBERr— TYPICAL WALL DETAILS SIDE VIEW NOTE: 1) Foundation anchor bolts at 60" o.e, as per 2000 IRC sec. R403.1.6 2) All framing and structural design to meet 90 m.p.h. wind criteria as per sm. R301.2.I and table R301.2(4) 2003 IRC code. 3) All lower sole plate to be Pressure treated as per sec. R323. All fasteners to be hot dipped galy. steel, stainless steel, silicon bronze or toper only as per sec. R323.3 4) Provide hand rails on all stairs/steps with a minimum of 2 risers as per sec. R315. (min. stair tread 10": max. riser 7 3/4" sec. R314.2) 5) Masonry veneer anchorage of 24" horizontal and 18' vertical as Spit per sec. R703.7A.I and weep holes No at a maximum of 33" o.c. as per O-DUO. 1 W MIN. sec.R703.7.6. :o:La•MAXSI]F. """"""""" -----------------------------' W o p IN. TREA 01 W • {—{ W E5: U Qo �o x STAIR DETAIL IRC 2003 ERE S-1.1. T PASS TNRU RI:111RNEND.STO 4" M'ALL DR RUST �U O Tu �O 18" FLOOR SYSTEM D (3)2x12 STRINGERS F 5/8" TYPE DRYWALL x UNDER STAIR STRINGERS a U HANDRAIL Q 34"-38" MAX. FIRST FLOOR CHIMNEY 214" 101011 MIN. CAP Z 2X4 BAND _ I 1 O 2X4 FRAMING MEMBER I ^ I 1 M••^i I I OSB I a' 1 W I lassie I I SIDING Century I I HomesI 1 0 IT hfaking Nome ON•nershlp AJjordablr I 1 Area Calculator: 1 2 Add to Library Window Name TO" x 5'0" 2'6" X 5'0" Assembly Type Y YP Metal Frame, Do Metal Frame, Do Quantity 6 2 Width 3'-0" 2'-0" xHeight 5'-0" 5'-0" Unit = Area 15.00 10.00 Total Area 90.00 20.00 ft2 ft2 U-Factor 0.650 SHGC 0.340 Comments/ Description 3 2'0" x 6'0" Metal Frame, Do 3 2'-0" 6'-0" 12.00 36.00 ft2 4 TO" x TO" Metal Frame, Do 1 T-0" T-0" 9.00 9.00 ft2 5 70" x 4'0" fixed -x Metal Frame, Do 1 4'-0" 4'-0" 16.001 16.00 ft2 0.650 0.340 6 2 - 3'0" 6'0' mulled Metal Frame, Do 3 6'-0" 6'-0" 36.00 108.00 ft2 7 8 Tx 1'6" AR TR 2 - 3'0" x 5'0" mulled Metal Frame, Do Metal Frame, Do 1 2 D = T-0" 6'-0" 1 57 3.53 30.00 3.53 60.00 ft2 ft2 0.650 0.650 0.340 0.340 9 6'0" x 3'0" AR TR Metal Frame, Do 2 6'-0" T-0" 18.00 36.00 ft2 10 11 3'0" x 6'0" Metal Frame, Do 1 T-0" 6'-0" 18.00 18.00 ft2 0.650 0.340 12 13 14 15 16 17 18 19 20 10/10/06 10:31:16 Window Area Total: 396.53 1/1 Area Calculator: Door Name -Tf-rontdoor Assembly Type 0 ME =0 Comments/ Description :VEMI ISO NONE MIN INS M MI M■�MIS ME INS �M■ ■ 001 MINES ME ' �M■ MAIM� ��■M■ INIMENMIN ME MIS ME ME INS 'IM M■����� ff�� ME m� MIN MIN■����� ' MIN■����� ' �M■ ■I I�� ®� ■�■M I�� ®� ��■�■I I�� ��■_EMIS IM _�_� ®� �ii ■MiI MINES� 10/10/06 10:31:17 Door Area Total: 55.56 1/1 +I 9ti09001-i1d I NOTES- 54'-10° D A S54 BS55 _-_-- -� r- - - II II 1 I � II II II I I II S57 I I I I g I I 3- #4 BARS 6-8° Np I I I I I II I II II S57 S57 2-BS58 r----------ir---= ----, ----------- Ir---------- r------- --, I I I I r I I I 1 I II II II II II II II II S57 I II I II II II II II II II 1 I I II it II II I +I S57 II 11 II II I II II II II A b I II II II II I M I II II IIL 11 I S57 @) ---------J L---- r---------�r---= ----J L-- -------J L---------J L--------- ----ter— -------ter—--------�r--------- BS58 li�l II II II as I II B l II II I II S57 N I II I co A I 11 II �? II II I II I 1 S57 I 101_91 III 1U-4° III 11'-1" III 11'-2° III 11'6° I I I L— — — — — — — — — J L — — — — I I I — — — — J L- — — — — — — — — — J L — — — — — — — — — — J — — — — — — — I S57 r----------ir---- I II ----�r---------ir----------ir------- II II II —� I BS58 I II II II II II II II II I S57 I II II DROP I I 11 I I I II II II I I I I II II I II II S57 I II I l iA II I I II L---------J L --- r---------fir --_ 11 II L 11 L-I -- —J --- —J — — ---- J — — — - -- ---- ,r- - - --- I S57 2-BS58 I I I I II � S24 M cnm I i i I I I W I m I DROP I I Lf) I U) U) u) u) F U) U) U) S24 II m m C S24 L - ------ L---- ----� BS25-------- ----� ii---= I II A I S24 II I II I S24 N I I ili I r- -� U) (1) U)U)U) U) U)U) C m M m N g• - - 5 SPACES @ 4'-1° t 4 SPACES @ 4'-1 ° t 4 SPACES @ 4!-T t 0- STEEL REQUIRED. SEE DETAILS 1. TO PREVENT SETTLEMENT DUE TO SOIL CONSOLIDATION, ALL EXTERIOR FOUNDATION BEAMS MUST BE FOUNDED A MINIMUM OF 12 INCHES INTO UNDISTURBED SOIL. WHEN FOUNDATION SITE CONTAIINS FILL (MAX. V-01, THE DEEPEN BEAM DETAIL SHOULD BE USED IN THESE FILLED AREAS. FOR SITES WHERE FILL IS GREATER THAN 3'-0°, PLEASE CONTACT AGTM ENGINEERING LLC TO INCORPORATE PIERS "';Z INTO THE DESIGN. 2. 3000 PSI, CONCRETE SLAB. 3. 4"OF CUSHION SAND UNDER CONCRETE SLAB IS RECOMMENDED. 4. PROVIDE A 6 MIL POLYETHYLENE MOISTURE RETARDER BENEATH SLAB AREA. 5. ALL STRANDS 1/2° DIA. - 270 K. 6. THIS FOUNDATION DESIGN IS CONSIDERED INVALID UNLESS ACCOMPANIED BY A LETTER FROM AGTM ENGINEERING LLC AUTHORIZING ITS USE ON A SPECIFIC LOT & BLOCK, OR ADDRESS. 7. PLANS CAN BE REVERSED ON LOT AT BUILDERS DISCRETION. 8. PLANS ARE FOR STRAND AND BEAM PLACEMENT ONLY. SET FORMS, DROPS, HANDICAP RAMPS, ETC., BY ARCHITECTUAL FLOOR PLAN OR AS SPECIFIED BY OWNER/GENERAL CONTRACTOR. 9. AT CONTRACTORS OPTION, LIVE END AND DEAD END REVERSAL IS PERMITTED. 10. AT CONTRACTORS OPTION, BRICK LEDGE MAY BE INCLUDED OR OMITTED AT EXTERIOR DOOR OPENINGS. M E, DRAINAGE, DRAINAGE. THE FINAL GRADE FOUNDATION SHALL BE 8^ BELOW THE TOP OF TION AND SLOPE AWAY FROM THE A MINIMUM OF TIN 5'-0^. 12. VIBRATE CONCRETE @ ALL CABLE LOCATIONS ESPECIALLY AT CORNERS WHERE SEVERAL CABLES ARE ANCHORED. MAXIMUM CONCRETE DENSITY IS REQUIRED TO INSURE THAT A °BLOW-OUT,° DOES NOT OCCUR DURING CABLE STRESSING. 13. THE FOLLOWING SYMBOL INDICATES DROP IN FOUNDATION. THE AMOUNT OF DROP AND EXACT o LOCATION IS TO BE DETERMINED BY PLAN OR AS c DIRECTED BY OWNER/CONTRACTOR. FOUNDATION: 1. THICKNESS T= 4" 2. BEAM WIDTH W= 10" 3. BEAM DEPTH D= 28" 4. AREA = 3128 SQ. FT 5. EST. CONCRETE = 94 YRDS. N THE EVENT THAT A CABLEUGH A PLUMBING OPENING, CAUTION: VIBRAE TO EDGE OF OPENING. AND DEAD ENDS TO ENSURE MAX.NG CAN BE ADJUSTED, BUT IN DENSITY CONCRETE, ESPECIALLY w N CABLE SPACING BE AREAS WHERE MULTIPLE STRANDS N 5'-W O.C. COME TOGETHER O Q W 02 CID Z0 :D Q T 0 ccm O X ' LL.�r-�O N ZZOz pw F-z '^0 zw co JLL W U) � Q U U) Q Z �U o O CL ru i T O U) w CL 8 ci a m w 0 W °c U n' W F-- 0 Z (� J J 0 U UO N VU0 Y z u) �:: m Z NZZO J Il — IZ m4� m O W J J O tp U O 3 ll! E 8 Q ` m z_�_�, 0 Wrnm'g �LLIJ H LL. J Q QW CID 0 O FLL— a 0 0 m O 0 Q BRICKLEDGE POST -TENSION STRANDS SLAB STRAND WHEN APPLICABLE WHEN INDICATED WHERE APPLICABLE 7N ON PLAN, TYPICAL TOP VIEW — —_ # 3 REBAR WITH 2'-U" �'_c. BRICKLEDGE POST TENSION STRANDS 1�a BENT @ 45° TYP Q WHEN APPLICABLE WHEN INDICATED �� ALL CORNERS ON PLAN, TYPICAL µ NOTE: IT IS IMPORTANT TO O a o CUSHION a F USE THIS DETAIL WHEN CHAIR SAND, TYP. o � CHAIR m - "' THERE IS A 4' OR LESS !� !. �y� ;.ty3 �' to a SLOPE IN THE FOUNDATION FOOT PRINT AREA. TO #4 BARS ° DRAPE BEAM STRAND VAPOR g 4 CHAIR INSURE THAT SETTLEMENT FORM BOARD SLAB 6° 2• #5 BARS WHEN INDICATED g 12° O.C. b #4 HAIRPIN STRAND CWHEN Al DETAIL ON PLAN, TYPICAL RETARDER SEE PLAN FOR EACH WAY `� -' ` BEAM DOES NOT OCCUR, THE TYPICAL F P D ENS ONS S� STRAND 2' X 3" X 2' g" "S°STRAND BOTTOM OF THE PERIMETER ANCHOR SPECIFIED "a DETAIL "A" a 4 BEAM MUST PENETRATE OR Al DETAIL "E" j :: • UNDISTURBED UNDISTURBED SOIL A NOTE: ONLY Al DETAIL HAS �� �� a SOIL GRADE N STEEL ON BOTTOM AS SHOWN �•.•'• MIN OF 12" END VIEW 2- #4 BARS VERTICALLY SLAB STRANDS BRICKLEDGE 4 SPACED Q 12" O.C. AS WHERE APPLICABLE WHEN APPUCABLE 1- #4 BACK UP BAR REQUIRED PER BEAM STANDARD DEPTH 'BS°STRAND z #4 BARS p 12° O.C.E.W. #4 VERTICAL ANCHOR g SLABSTRAND SUPPORTS HAIRPIN DETAIL DEEPEN BEAM T—BS" DETAIL a DETAIL WHEN SPECIFIED CHAIR < .�- y:.r:;'y/.« wia, r•"wse•.- HAIR BEAM STRAND SLAB STRAND .. WHERE APPLICABLE POCKET FORMER STRIP SHEATHING 1° 2- #5 BARS. BEAM STRAND 1 ° O'A' HOLE Q LIVE END WHEN Bt DETAIL SEE PLAN VARIED�N. POST-TENSION STRANDS IN FORM IS SPECIFIED 3' 0" MAX. yy AS SPECIFIED DROPPED 4-WHEN INDICATED BRICKLEDGE 1- #4 BACK UP BAR BOARD DETAIL "Bo BRICK ON PLAN, TYPICAL WHEN APPLICABLE #4 BARS p 12" O.C.E.W. NOTE: ONLY B1 DETAIL HAS �� �� LI II 1a SLAB STRAND STEEL ON BOTTOM AS SHOWN OR B 1 DETAIL F e v, MATCH PLASTIC DROPPED Z N EXCESS SHEATHING ' BRICKLEDGE 'D — n ti• STRAND TO god NAIL N BE STRESSED io AND CLOT FORM BOARD p BRICKLEDGE SLAB STRAND BRICKLEDGE 1- #4 BACK UP BAR Z z CHAIR ';. CHAIR WHEN APPLICABLE 2 WHERE APPLICABLE WHEN APPLICABLE DEAD END ANCHOR 9#4 BARS 12" O.C.E.W..? SLAB STRAND STRIP SHEATHING SLAB STRAND ' ®DEAD END DEAD END Z Z 6 DRAPE BEAM STRAND BEAM STRAND ANCHOR `O cO F 2- #4 BAPS 5° WHEN INDICATED 11-0° OR ��ti. • °e' ' . :, LESS AS SPECIFIED TOP VIEW ON PLAN, TYPICAL o NOTE: END OF CHAIR-.�st,�=�4:f:_,�,:: DETAIL I'J'I DETAIL "MI' PLASTIC SHEATHING CABLE IS 3/4° CHAIR 20d NAIL AWAY FROM ° DRAPE BEAM STRAND DROPPED BRICKLEDGE 1 MIN. FORM BOARD FORM BOARD. 2- #5 BARS WHEN INDICATED SLAB STRANDS HEN C1 DETAIL ON PLAN, TYPICAL E P DRAPE BEAM STRAND IS SPECIFIED WHEN INDICATED FORM CARD ON PLAN, TYPICAL °S" STRAND AS HAIR NOTE: ONLY C 1 DETAIL HAS DETAIL ��c�� DETAIL "G" SHOWN ON PLAN =E:N TTOM AS SHOWN O R "Cl " Q~QZU - BRICKLEDGE " ~ TIE WIRE WHEN APPUCABLE SLAB STRAND SLAB STRAND WHERE APPUCABLE CHAIR LESS THAN 54" z � � - ,. • � STANDARD DETAILS "BS° STRAND AS a. 2 X D TYPICAL o O SHOWN ON PLAN UCHAIR SLAB STRANDS CHAIR #3 STAKES AS REQUIRED WHEN (2) "BS°STRANDS ARE CHAIR STIRRUPS TO MAINTAIN A 3° WHEN SPECIFIED CLIARANCE FROM THE SPECIFIED IN THE BEAM, TIE STIRRUPS BOTTOM OF THE BEAM ANDINSTALLLTOGETHER SIDEL S DE BY D=1 TOR LESS i•� 3- #4 BARS TOP WHEN SPECIFIED 3- #4 BARS TOP 54" MAX SP,4CING AS A SINGLE °BS" STRAND. AND BOTTOM W AND BOTTOM W INSTALL ANCHORS SIDE BY SIDE SEE °2-BS° DETAIL 1:6 SLOPE DETAIL I'D" DETAIL "H" BEAM STRAND "BS" DETAIL STANDARD DROP DETAIL 11 5'-0" MIN. LESS THAN 23-0" 5'-O" MIN. REAR 5'-O" MIN. LESS THAN 25-0" 7&-9' LEFT FRONT 5'-0" MIN. 0 5'-O" MIN. SEE DETAIL I-STORv z-a MIN. r` 5'-0" MIN. 2'-T LESS THAN 26-0" TYP. 0V09001 dM8 REAR FRONT J W w W 2 .- c� z Q =H �: ti P2 co co 0, ��VO IC-0- 0 qt C V U Y � _I F- N Z o O� d m °C W � Z Z �� m 0Tzw ZNZZ J�0 Q� a z w pC m U ° O 0 J J O m U O = O � O w CL 8 r- a d m r m c °` x O U m o LU a a m U O Q o O rW- o co uVi m -J W E g w � •� < C? z�� cj .� W LL J "a Q w m 3" GRID PATTERN 8d COMMON NAILS TO HEADER TOP PLATE TO HEADER - 2 ROWS OF 18d SINKERS, 3-O.C. 3 O.C. NAILING IN ALL FRAMING -STUDS, BLOCKS, TOP PLATE, AND BEHIND THE STHD10 HOLDDOWN MIN. 3/8" WOOD STRUCTURAL PANEL SHEATHING (SINGLE SIDED FOR 1 STORY.) EDGE NAIL 8D COMMON, all O.C. 0 STORY) FIELD NAIL 8D COMMON, 12" O.C. 2 - 2' ANCHOR BOLTS EMBEDDED 7" MIN. (1 STORY) 1800 LB HOLDOWN " 3 BOTTOM PLATE TYPICAL FRONT VIEW SIMPSON LSTA21 OR CS20 (ATTACH L24"MIN.1, TO FRAMING ON OPPOSITE SIDES OF SHEATHING) TYPICAL BOTH SIDES r-OF OPENING. ILI1- 5/8" ANCHOR BOLT EMBEDDED 7" MIN. TYPICAL HEADER CLEAR SPAN ACROSS 2- SIMPSON STHD14 EACH SIDE - TYPICAL 1-ST0RY - 24"MIN. ONE-STORY STRUCTURES CAN USE SIMPSON HTT16, PHD2, HDU2, OR STHD10 HOLDOWNS. CALTERNATE 1 STORY- 2' 8" MIN_ ) TYPICAL BOTH SIDES FRONT VIEW HEADER CLEAR SPAN ACROSS 2- SIMPSON STHD10 2'-8° MIN MIN. 3/8" WOOD • STRUCTURAL PANEL • SHEATHING (SINGLE SIDED FOR 1 STORY.) • EDGE NAIL 8D COMMON, 8" O.C. (1 STORY) FIELD NAIL 8D COMMON, 12" O.C. d milm''m 0 I 2 - z' ANCHOR BOLTS EMBEDDED 7" MIN. (1 STORY) U4 EMBEDDED IN CONCRETE 1 11211 @ SLAB POUR - TYPICAL TYPICAL BOTH SIDES r -STORY = 2'=8'"MIN 'it Nov 28 06 04:29p Tony Medina (972) 875-1398 p.2 neering, LLC 2UU6 Attn: Terry City of College Station Inspection Department/Plan Review Subject: Classic Century Homes Brace Wall Panel Design Calculations for the following addresses: 1. 2441 Newark Circle 2. 2443 Newark Circle 3. 2447 Newark Circle 4. 2449 Newark Circle 401 S. CLAY STREET In all of the above plans, one or more of the Code 8 prescriptive methods were used. For these methods, calculations were not performed. Calculations are herein provided for the alternate braced wall panels used. The following lists the address and the alternate braced wall panels designated by panel width. Address 2441 Newark Circle 2443 Newark Circle 2447 Newark Circle 2449 Newark Circle Alternate Panel -Width 16" 16" and 2'8" 24" and 2' 8" 16" and 2' 8" For the above addresses there are 3 types of brace wall panels, 16", 24" and 2'8". The attached calculations are from a Brace Wall Panel Computer Program provided by Simpson Strong ties. Although the panels specified on the plans are not Sinv.. gn wall, the theory, Ioads and calculations are the same for a given width. Please call if you have any questions. Sincerely, r. A Oi VIEDINA �# �'D�Q/STEctiG� r U� A.G. (Tony) Medina Registered Professional Engineer P.S. The computer program references the IBC, as per the attached. The brace wall panels design are typical for both the IRC and the IBC. PHONE: 972.878.ENGR (3647) - FAX: 972.875.1398 • E-MAIL: info@txroundations.com TX 75119 .1 Nov 28 06 04:29p Tony Medina (972) 875-1398 p.3 L2441ewark circle ine 1 Design Criteria: " IBC 2003 * 2500 psi concrete * Design V Aso - 800 lbs wind * Alternate Basic or Basic Load combination selected wall solution: Model (TypeUJH IT Shear uplift ISill A.B. End A.B. sw16x8x4 IlwoodI90" I4" IDeosiln 400 lb 12179 lb jAxiallLoad 1000 lb I2 - S/8" 12-SSTBz8 Actual Shear & Drift Distribution: Model JAllow. v ID allow Ik IRR Iv dist check D actual sw16x8x4 1245 lb 0.42" 2964 I0.50 400 lb 400 <- 1245 - YES I0.135" .Sw16x8x4. 11245 lb 10.42" 12964 10.50 400 lb Ishear 400 <= 1245 = YES 10.135" 2 - sw16x8x4 are OK along the same wall line Le end for Shear & Drift Distribution: Allow. V = Maximum allowable shear D allow m Drift at maximum allowable shear k = stiffness = Maximum allowable shear / Drift at maximum allowable shear RR - relative stiffness - k / sum k v dist Distributed Design shear = Design shear x RR shear check verifies that the distributed shear is less than the allowable shear D actual = Drift at the distributed design shear Notes: * see current catalog for SSTB allowable loads and installation. * using actual wall ht dimension (H), specify proper concrete curb height to attain overall header rough opening height above slab. * Allowable shears for 7 ft wood garage portal walls assume double portal values for an even number of wall segments. when the total number of wall segments is an odd number, one wall is assumed to have a single portal shear load capacity. uplift is reduced for axial load. However combined effect of axial and lateral forces on the wall is not considered. see Allowable vertical Loads at: www.strongtie.com/products/strongwall/allowable_vertical.html Disclaimer: It is the designer's responsibility to verify product suitability under applicable building codes. in order to verify code listed applications please refer to the appropriate product code reports at www.strongtie.com or contact Simpson Strong -Tie Co., Inc. at 1-800-999-5099. NO stioer t o F 4 br i Nov 28 06 04:29p Tony Medina (972) 875-1398 p.4 2443 Newark circle Wall Line 1 Design criteria: * Isc 2003 * 2500 psi concrete * Design v ASD - 800 lbs wind * Alternate Basic or Basic Load combination selected wall solution: Model Type IW 1H T IDesign shearluplift (Axial Load Isill A.B. (End A.B. SW22x8x4 wood I22" 190" =4" 1800 lb 12367 lb 11000 lb 12 - 5/8" 12-SSTS28 shear & Drift values: model [Allow. v ID actual shear check SW22x8x4' 11995 lb 10.179" 1800 <- 199S = YES 1 - sw22x8x4 is OK Legend: Allow. V = Maximum allowable shear o allow Drift at maximum allowable shear shear check verifies that Design v ASO is less than the allowable shear Notes: * see current catalog for SSTB allowable loads and installation. * using actual wall ht dimension (H), specify proper concrete curb height to attain overall header rough opening height above slab. * Allowable shears for 7 ft wood garage portal walls assume double portal values for an even number of wall segments. when the total number of wall segments is an odd number, one wall is assumed to have a single portal shear load capacity. uplift is reduced for axial load. However combined effect of axial and lateral forces on the wall is not considered. see Allowable vertical Loads at: www.strongtie.com/products/strongwall/allowable_vertical.html Disclaimer: It is the designer's responsibility to verify product suitability under applicable building codes. In order to verify code listed applications please refer to the appropriate product code reports at www.strongtie.com or contact Simpson strong -Tie co., Inc. at 1-800-999-5099. j('11 P-� 144t �W,4,-Vk -TAtc.o., 116-- FD(L- 21-6 it., kw�) tA- 5 A61K- Z o� 4 i Nov 28 06 04:30p Tony Medina (972) 875-1398 p.5 �447 Newark Circle Wall Line 1 Design Criteria: * IBC 2003 * 2500 psi concrete * Design v Aso - 800 lbs wind " Alternate Basic or Basic Load combination selected wall solution: model SW22x8x4 1wood 122,' 190" 14" I800Design lb shear12367flb shear & Drift values: Model Allow. v ID actual Ishear check SW22x8x4 11995 lb 10.179" 1800 <= 1995 = yEs 1 - SW22x8x4 is OK IAxial Load ISill A.B 11000 lb 12 - S/8" Legend: Allow. v = maximum allowable shear D allow a Drift at maximum allowable shear shear Check verifies that Design v ASD is less than the allowable shear IEnd A.B. 12-SSTB28 Notes: * see current catalog for SSTS allowable loads and installation. " using actual wall ht dimension (H), specify proper concrete curb height to attain overall header rough opening height above slab. * Allowable shears for 7 ft wood garage portal walls assume double portal values for an even number of wall segments. when the total number of wall segments is an odd number, one wall is assumed to have a single portal shear load capacity. Uplift is reduced for axial load. However combined effect of axial and lateral forces on the wall is not considered. see Allowable vertical Loads at: www.strongtie.com/products/strongwall/allowable-vertical.html Disclaimer: It is the designer's responsibility to verify product suitability under applicable building codes. In order to verify code listed applications please refer to the appropriate product code reports at www.strongtie.com or contact Simpson strong -Tie Co., Inc. at 1-800-999-5099. -c+l�s is F- u PL- ZcL'� - z- Ig 5l-}1tiG�' Nov 28 06 04:30p Tony Medina r' 2447 Newark circle Wall Line 1 Design criteria: * xBc 2003 * 2500 psi concrete * Design V ASD - 800 lbs wind * Alternate Basic or Basic Load combination Selected wall solution: Model IType Iw IH IT Design shearluplift sw22x8x4 (wood 122" 190" 14" 1800 lb 12367 lb shear & Drift values: Model Allow. v ID actual Ishear check sw22x8x4 I1995 lb 10.179" 1800 <= 1995 = YES 1 - sw22x8x4 is ox (972) 875-1398 (Axial Load Isill A.B. (End A.B. 11000 lb 12 - 5/8" 12-SSTB28 Legend: Allow. v = Maximum allowable shear D allow = Drift at maximum allowable shear shear check verifies that Design v ASD is less than the allowable shear Notes: * see current catalog for SSTB allowable loads and installation. * using actual wall ht dimension (H), specify proper concrete curb height to attain overall header rough opening height above slab. * Allowable shears for 7 ft wood garage portal walls assume double portal values for an even number of wall segments, when the total number of wall segments is an odd number, one wall is assumed to have a single portal shear load capacity. uplift is reduced for axial load. However combined effect of axial and lateral forces on the wall is not considered. see Allowable vertical Loads at: www.strongtie.com/products/strongwall/allowable-vertical.html Disclaimer: it is the designer's responsibility to verify product suitability under applicable building codes. In order to verify code listed applications please refer to the appropriate product code reports at www.strongtie.com or contact Simpson strong -Tie co., Inc. at 1-800-999-5099. p.6 BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS A)J"M `--" COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: .(979) 764-3496 ---------------------------------------------------------------------------- Application Number 06-00003540 Date 12/08/06 Property Address . . . . . . 2447 NEWARK CIR Property ID: 184200-1502-0020 R #: R300537 .Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . CASTLEGATE SEC 5 PH 1 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 163416 Owner Contractor ------------------------ ------------------------ GREENS PRAIRIE INVESTORS LTD CLASSIC CENTURY HOMES 4490 CASTLEGATE DR 5001 HWY 287 S COLLEGE STATION TX 778453388 ARLINGTON TEXAS BURLESON TX 76028 (817) 561-4369 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID PD FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 2476.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC TAZ 441.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . GS Permit Fee . . . . 652.00 Plan Check Fee .00 Issue Date . . . . 12/08/06 Valuation . . . . 163416 Expiration Date . . 6/06/07 Qty Unit Charge Per Extension BASE FEE 460.00 64.00 3.0000 THOU BLDG, VAL 100001-500000 192.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN A C-FAULT CIRCUIT INTERRUPTER(S) -------------------------------------------- -- - -------- BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AV'E COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 06-00003540 Page 2 Date 12/08/06 Special Notes and Comments PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12' ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved belo the slab, seal ------------------------------------------------ ---- ��------- BUILDING DEPT REPRESENTATIVE APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 3 Application Number 06-00003540 Date 12/08/06 ---------------------------------------------------------------------------- Special Notes and Comments annular space at ends with caulk, foam or other means. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE For residential applications with a glazing area that exceeds 150 of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE ------------------------------------------------- --- /`� -------- BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE ' COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 4 Application Number 06-00003540 Date 12/08/06 ---------------------------------------------------------------------------- Special Notes and Comments RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged ---------- Paid Credited Due ------------------------------ ----------------- Permit Fee Total 652.00 652.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1402.00 1402.00 .00 .00 --------------------------------------------- ----- ----G��---------- BUILDING DEPT REPRESENTATIVE: APPLICANT: TZ ! TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 06-00003541 Date 12/08/06 Property Address . . . . . . 2447 NEWARK CIR Property ID: 184200-1502-0020 R #: R300537 Application type description TEMP POLE Subdivision Name . . . . . . CASTLEGATE SEC 5 PH 1 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 0 Owner Contractor ------------------------ GREENS PRAIRIE INVESTORS LTD ------------------------ CLASSIC CENTURY HOMES 4490 CASTLEGATE DR 5001 HWY 287 S COLLEGE STATION TX 778453388 ARLINGTON TEXAS BURLESON TX 76028 (817) 561-4369 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . GS Permit Fee . . . . 20.00 Issue Date . . . . 12/08/06 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited ------------------------------ Due --------------------------- Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 ----------------------------------------------- ------ - -------- BUILDING DEPT REPRESENTATIVE: APPLICANT: