HomeMy WebLinkAboutDEMO2006-03514ray
DEMOLITION PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570:,, FAX: (979)764-3496
------------------------------------`=---------------------------------------
Application Number . . . . . 06-00003514 Date 11/22/06
Property Address . . . . . . 1643 TEXAS AVE S
Property ID: 213500-0002-0060
R #: R25422
Tenant nbr, name . . . . . . INTERIOR DEMO
Application type description DEMOLITION, COMMERCIAL
Subdivision Name . . . . . . CULPEPPER PLAZA
Property Use . . . . . . . . BUSINESS
Property Zoning . . . . . . . GENERAL COMMERCIAL
Application valuation . . . . 8000
Owner Contractor
------------------------ ------------------------
CFP I L.P. T R S CONSTRUCTION, INC
3901 BELLAIRE BLVD 600 KENRICK DR STE D14
HOUSTON TX 770251119 HOUSTON TX 77060
(281) 847-4405
--- Structure Information 000 000 INTERIOR DEMO OF TENANT SPACE
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . BUSINESS
Other struct info . . . . . TAZ 348.00
----------------------------------------------------------------------------
Permit . . . . . . DEMOLITION PERMIT
Additional desc . . KW
Permit Fee . . . . 25.00 Plan Check Fee .00
Issue Date . . 11/22/06 Valuation . . . . 8000
Expiration Date . . 5/21/07
Qty Unit Charge Per Extension
BASE FEE 25.00
----------------------------------------------------------------------------
Special Notes and Comments
THE TEXAS DEPARTMENT OF HEALTH REQUIRES AN ASBESTOS SURVEY
IN CERTAIN CIRCUMSTANCES - CALL TDH @ (254) 778-6744 FOR
MORE INFORMATION
CONSTRUCTION ACTIVITY BETWEEN THE HOURS OF 10:00 PM AND
7:00 AM MUST COMPLY WITH THE NOISE ORDINANCE (MAX. 55 DBA)
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
---------,-�----- --- ---- - _ - --------------------
BUILDING DEPT REPR�ESENTVE :���
APPLICANT:
�i
DEMOLITION PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page 2
Application Number . . . . . 06-00003514 Date 11/22/06
---------------------------------------------------------
Permit Fee Total 25.00 25.00 .00 .00
Plan Check Total .00 .00 .00 .00
Grand Total 25.00 25.00 .00 .00
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
CITY OF COLLEGE STATION (979) 764 ,3570 (979) 761-3496 FAX
Pbrnhg d tkarpp,RexSe+z6crr
W W W.CSTX.GOV
ADDRESS/LOCATION:
DATE: //TRCC REG 11
APPUCATIONs
TEMP POLE #
LOT BLOCK SUBDIVISION SEC/PH
III I
BUSINESS/OWNER NAME: PHONE:1i-C&O•4340
CONTRACTOR/HOMEOWNER: tG. PHONE: *I.81f7.5fYoS
CONTRACTOR ADDRESS: 660 V~4Lk A". 50%;k D'1 ■`, gcac>Ic1�,.TAOE'770
ELECTRICIAN: r ,IA PLUMBER: iVj
HVAC: / �F A GOOD CENTS (Rewemial onty):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTIONSLAB ONLY
DUPLEX (Landscape Plans REMODEL/RENOVATION' SWIMMING POOL
Required) 1
DESCRIPTION OF WORK: 4 �a11� 0a*
J ' i
STRUCTURE USE:
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APP VAL: _ AIA
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ Ai
®o VALUATION: $ 45000 TOTAL AREA:2-6001 HEATED AREA:
(Cost of Labor and Materhals)
v PUBLIC SEWER NUMBER OF BEDROOMS: - NA
SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS:
SEWER TAP: INTERIOR WALL TYPE: 14A-
SIZE
WATER TAP: EXTERIOR WALL TYPE: AIA
SIZE
OTHER TAP: FOUNDATION TYPE:
SIZE
TEMP POLE ROOF TYPE:
GARAGE TYPE. SINGLE DOU ED TRIPLE Dy..
P� ATTACHED DET CARPORT �{
SIGNATURE OF APPLICANT:
'If proposed work involves new commercial construction or facade improvements/renovations to an existing
commercial property, building elevations are required.
Oflitfal Use Only
Comments:
kz ES o NO
Plans Examiner Zoning Official
., ASBESTOS CONSULTANTS, INC.
The Woodlands, Texas
New Plan Excel Realty Trust, Inc.
3901 Bellaire Blvd.
Houston, Texas 77025
Attention: Mr. Robert Scott
RESULTS OF ASBESTOS SURVEY
November 10, 2006
ACI Project No. 2006-121
VACANT LEASE SPACE (#11) LOCATED AT 1643 S. TEXAS AVENUE
CULPEPPER PLAZA SHOPPING CENTER
COLLEGE STATION, TEXAS 77840
Introduction
This report presents the results of the asbestos survey performed for the vacant 2,000 square foot lease space located
at 1643 S. Texas Avenue, in Culpepper Plaza Shopping Center, in College Station, Texas. This survey was
authorized by Mr. Scott with New Plan on November 6, 2006, and performed in general accordance with our
confirmed scope of services.
Purpose and Scope. The purpose of this survey was to determine if asbestos is present in the existing building
materials within the vacant lease space located at 1643 S. Texas Avenue in College Station, Texas. The scope of
services included performance of the following tasks:
• Collect and analyze representative samples of suspect asbestos -containing materials, and
• Prepare a report discussing results from laboratory testing and presenting recommendations/conclusions.
Report Organization. This report is divided into sections that discuss the field investigation, laboratory analyses
and results. Supporting documentation follows the text.
Field Survey
The asbestos survey was conducted on November 8, 2006, by Shawna McIntyre, TDSHS licensed Asbestos Inspector
(No. 602648) with Asbestos Consultants, Inc. (1DH Asbestos Consultant Agency License #10-0120), and included
representative sampling of suspect asbestos containing building materials within the lease space. Asbestos
Consultants, Inc. looked for suspect ACBM in accordance with the Asbestos School Hazard Abatement
Reauthorization Act. (ASHARA) of 1990.
Observations
Gray carpet with yellow mastic over clean concrete was common throughout the majority of the main retail area.
Tan, nonfriable 9-in. x 9-in. floor the with yellow mastic ( 40 square feet) is present in the entryway. Red carpet
with yellow mastic over clean concrete is common to the back offices and rest room.
The perimeter and interior built-up walls within the lease space are constricted of nonfriable gypsum board
(Sheetrock) with friable dry wall joint compound and textured paint.
A file ceiling with gray, friable, 24-in. x 48-in. ceiling tiles with white paint are common to the lease space. The
grid for the ceiling is suspended beneath structural steel beams and the metal roof deck. Friable spray -applied
insulation/texture is present on the metal roof deck.
Metal HVAC duct and fiberglass -insulated flex duct were observed above the suspended file ceiling.
P.O. Box 131114 The Woodlands, Texas 77393-1114 Tel. No.: (932) 813-0660 Fact No.: (832) 813-0661
Mr. Robert Scott November 10, 2006
New Plan Excel Realty Trus% Inc. Project 2006-121
Sampling. Suspect asbestos -containing building .materials (ACM) are classified as surfacing, thermal or
miscellaneous materials. Sampling during the field investigation was conducted in accordance with the Texas
Asbestos Health Protection Rules, and included the collection of twelve bulk samples of suspect miscellaneous
materials. The samples were subsequently submitted to Envirotest, Inc., a TDSHS licensed asbestos laboratory
(TDSHS license 03-0005), for analysis. Table 1 presents details of the bulk sample type and location.
In general, three representative samples of each suspect building material were taken from random locations
throughout the lease space. For this survey, the following suspect building materials were sampled:
• Nonfriable 9-in. x 9-in. floor tile with yellow mastic, no damage,
• Friable spray -applied ceiling insulation / texture, no damage,
• Friable 24-in. x 48-in. ceiling tiles with white paint, no damage, and
• Nonfriable wallboard (gypsum/Sheetrock) with dry wall joint compound and white paint, no damage.
Friable ACBM is a material that, when dry, can be crumbled, pulverized, or reduced to powder by hand pressure.
Nonfriable ACBM can be pulverized or reduced to powder only during machining, cutting, drilling, or other
abrasive procedures. Friable ACBM is more likely than nonfriable ACBM to release asbestos fibers when disturbed.
All samples were collected in a manner that reduced the potential for fiber release and exposure, using amended
water and personal protective equipment where necessary. After recovery, samples were placed in secure containers
for transport to Envirotest, Inc. Appropriate chains of custody protocols were initiated at this time. Sampling of
glass and/or nonfriable brick were not included as part of this survey..
Laboratory Analyses
Bulk samples were analyzed by a trained analyst(s) using Polarized Light Microscopy (PLM) according to the US
EPA Interim Method for the Determination of Asbestos. This technique characterizes the material's refractive
indices, fiber morphology, birefringence, extinction angle, and sign of elongation, and dispersion staining colors to
detect _ asbestos. Percentage compositions are based on approximate area compositions (by visual area estimation)
under a stereomicroscope. A material is considered an asbestos -containing material (ACM) if it contains greater
than one- percent asbestos as analyzed by calibrated visual area estimation (PLM). The results of the bulk sample
analyses are given in Table 1.
Laboratory analyses results show no asbestos being detected in the suspect building materials sampled within the
lease space. Original laboratory bulk sample test results are presented in Appendix I.
Conclusions
Based on results of the laboratory analysis, no asbestos is present in the suspect building materials sampled
within the lease space located at 1643 S. Texas Avenue, in Culpepper Plaza Shopping Center, in College
Station, Texas.
Page 2
Mr. Robert Scott
New Plan Excel Realty Trust, Inc.
November 10, 2006
Project 2006-121
Limitations
This report presents the results of the asbestos survey performed for the vacant lease space located at 1643 S. Texas
Avenue in College Station, Texas. This report describes only conditions present at the time of my survey in the areas
surveyed. The reported observations and conclusions are limited only by the reported assumptions and limiting
conditions and represent our unbiased and professional analysis, opinions, and conclusions. Asbestos Consultants,
Inc. should be contacted if building materials (including surfacing textures, flooring, etc.) different than those
observed and/or encountered during this survey are uncovered during the demolition /renovation of the lease space.
Destructive sampling procedures (drilling through the roof, walls, floors, and ceilings) were not used or authorized.
This work was conducted using standard principles and practices, and the scope of this report is limited to the
matters expressively covered. Asbestos Consultants, Inc. makes no warranties, expressed or implied, including
without limitation, warranties as to the marketability of the site or fitness for a particular use. Information in this
report is not to be construed as legal advice.
Information presented in this report from third parties (i.e.- TDSHS-licensed asbestos laboratories (Envirotest, Inc.))
was obtained from sources deemed to be reliable. Asbestos Consultants, Inc. does not represent or warrant the
accuracy of this information.
Warranties and liabilities as to the service performed are limited to the cost of the survey. This report and the
findings contained herein shall not, in whole or in part, be dispersed or disclosed to any other party without prior
written consent from Asbestos Consultants, Inc. and/or representatives with New Plan Excel Realty Trust, Inc.
Closing
The following table and appendix are attached and complete this report:
Table 1 Bulk Sample Summary
Appendix I Original Laboratory Test Results
I appreciate the opportunity to provide these services to New Plan. Please call me at (713) 252-5360 if you have any
questions or require any additional information. I'll contact you later this week to discuss the results and answer any
questions that you may have.
CAReporU\2006-121-CulpepperPlaza-1643-svy.doc
Very Truly Yours,
ASBESTOS CONSULTANTS, INC.
G�* �fc d'5z.-)
Patrick D. McIntyre, P.E.
Licensed Asbestos Consultant (TDH License # 10-5331)
Page 3
TABLE 1
TABLE 1- BULK SAMPLE SUMMARY
SAMPLE NO.
DESCRIPTION
ASBESTOS CONTENT
HM-01
-Tan, nonfriable 9-in. x 9-in. floor tile with yellow mastic
No Asbestos Detected
common to the foyer / entryway. No damage. (— 40 s.f.).
Sample from corner of entryway.
FM-02
Tan, nonfriable 9-in. x 9-in. floor tile with yellow mastic
No Asbestos Detected
common to the foyer / entryway. No damage. (— 40 s.f.).
Sample from comer of entryway.
HM-03
Tan, nonfriable 9-in. x 9-in. floor tile with yellow mastic
No Asbestos Detected
common to the foyer / entryway. No damage. (— 40 s.f.).
Sample from comer of entryway.
HM-04
White nonfriable wallboard with friable dry wall joint
No Asbestos Detected
compound common to interior walls. White paint on
exterior surface. No damage. Sample from corner of
left wall in main retail area..
HM-05
White nonfriable wallboard with friable dry wall joint
No Asbestos Detected
compound common to interior walls. White paint on
exterior surface. No damage. Sample from comer of
back wall in main retail area.
HM-06
White nonfriable wallboard with friable dry wall joint
No Asbestos Detected
compound common to interior walls. White paint on
exterior surface. No damage. Sample from corner of
wall in back storeroom.
FM-07
Gray/tan, friable, fibrous 24" x 48" ceiling the with white
No Asbestos Detected
paint exterior on grid suspended beneath structural steel
stringers and metal roof deck. No damage. Common
throughout the lease space. Sample from front of main retail
area.
HM-08
Gray/tan, friable, fibrous 24" x 48" ceiling file with white
No Asbestos Detected
paint exterior on grid suspended beneath structural steel
stringers and metal roof deck. No damage. Common
throughout the lease space. Sample from back of main
retail area.
HM-09
Gray/tan, friable, fibrous 24" x 48" ceiling file with white
No Asbestos Detected
paint exterior on grid suspended beneath structural steel
stringers and metal roof deck. No damage. Common
throughout the lease space. Sample from canter of storeroom.
TABLE 1- BULK SAMPLE SUMMARY
SAMPLE NO. DESCRIPTION
HM-10 Brown friable, fibrous spray -applied insulation common to
the metal roof deck above the suspended tile ceiling.
No damage. Sample from left side of ceiling
HM-11 Brown friable, fibrous spray -applied insulation common to
the metal roof deck above the suspended tile ceiling.
No damage. Sample from right side of ceiling.
HM-12 Brown friable, fibrous spray -applied insulation common to
the metal roof deck above the suspended tile ceiling.
No damage. Sample from center of ceiling.
ASBESTOS CONTENT
No Asbestos Detected
No Asbestos Detected
No Asbestos Detected
NOTES:
(1) Samples analyzed by Envirotest Inc.'s Laboratory (TDH License # 30-0005, NVLAP # 101595), a successful
participant in the NVLAP Laboratory Accreditation program.
APPENDIX I
ORIGINAL LABORATORY TEST REPORTS
Envirotest, Ltd. Polarized Light Microscopy Report - Job #106541
Analytical Method: EPA 600 / R-93 / 116 Analyst Name: Brindley, Terry Analyst's Initials: %B
Client Name: Asbestos Consultants, Inc.
Client Reference: 06-121
Envirotest Reference: W06-989
Client Sample #
Layer #: Layer Description
Asbestos
Asbestos Type - %
Non -asbestos Fiber Type - %
(Lab Sample #)
Present
and/or Matrix Material - %
HM-1
1: Tan Sheet Flooring w/ Tan Backing
No
Cellulose - 05%
(106541-1)
Fiberglass - <1%
HM-2
1: Tan Sheet Flooring w/ Tan Backing
No
Cellulose - 05%
(106541-2)
Fiberglass - <1%
HM-3
1: Tan Sheet Flooring w/ Tan Backing
No
Cellulose - 05%
(106541-3)
Fiberglass - <1%
2: Yellow Mastic
No
Cellulose - <1%
HM4
1: White Powder w/ Paint
No
Cellulose - <1 %
(106541-4)
2: White Drywall
No
Cellulose - 02%
HM-5
1: White Powder w/ Paint
No
Cellulose - <1 %
(106541-5)
2: White Drywall
No
Cellulose - 02%
3: Brown/White Fibrous Material
No
Cellulose - 80%
HM-6
1: White Powder w/ Paint
No
Cellulose - <1%
(106541-6)
2: White Drywall
No
Cellulose - 02%
3: Brown/White Fibrous Material
No
Cellulose - 80%
HM-7
1: Tan Fibrous Material w/ White Coating
No
Cellulose - 40%
(106541-7)
Mineral / Glass Wool - 20%
HM-8
1: Tan Fibrous Material w/ White Coating
No
Cellulose - 40%
(106541-8)
Mineral / Glass Wool - 20%
HM-9
1: Tan Fibrous Material w/ White Coating
No
Cellulose - 40%
(106541-9)
Mineral / Glass Wool - 20%
HM-10
1: Brown Fibrous Material
No
Cellulose - 99%
(106541-10)
HM-11
1: Brown Fibrous Material
No
Cellulose - 99%
(106541-11)
Envirotest, Ltd. Polarized Light Microscopy Report - Job #106541
Analytical Method: EPA 600 / R-93 / 116 Analyst Name: Brindley, Terry Analyst's Initials: 19
Client Name: Asbestos Consultants, Inc.
Client Reference: 06-121
Envirotest Reference: W06-989
Client Sample #
Layer #: Layer Description
Asbestos
Asbestos Type - %
Non -asbestos Fiber Type - %
(Lab Sample #)
Present
and/or Matrix Material - %
HM-12
1: Brown Fibrous Material
No
Cellulose - 99%
(106541-12).
Asbestos content percentages are reported by area percent estimation. < = less than, > = greater than. Conversion
of area percent to dry weight is not feasible unless the specific gravities and relative volumes of the different matrix
materials are known. Accuracy and precision of the analysis is dependent upon the following items: quantity of
sample analyzed, homogeneity of the sample, nature of matrix interference, sample preparation techniques, fiber
size, material type, and the percent of asbestos involved.
Inhomogeneous samples are separated into sub -samples and each layer is analyzed and reported separately, where
applicable.
Job notes / analytical problems / method departures: none
Reviewed By:
Y