HomeMy WebLinkAboutRES2006-03509r
PREPARED 7/31/07, 12:10:07 INSPECTION TICKET PAGE 1
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 7/31/07
------------------------------------------------------------------------------------------------
ADDRESS . : 1501 BLUEFIELD CT SUBDIV: SHENANDOAH PH 19
CONTRACTOR ED FROEHLING BUILDERS PHONE (979) 776-8266
OWNER ED FROEHLING BUILDER INC PHONE
PARCEL 569500-1947-0100
APPL NUMBER: 06-00003509 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT_ BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 12/07/06 RH BLDG, FOUNDATION -SLAB TIME: 17:00
12/07/06 AP December 7, 2006 10:47:01 AM glsouth.
December 7, 2006 4:22:09 PM ncochran.
STRINGS UP. SLAB GROUND INSTALLED.
B115 01 2/09/07 OC BLDG, FRAMING TIME: 17:00
2/09/07 AP February 5, 2007 3:34:40 PM ncochran.
B130 01 2/15/07 RH BLDG, INSULATION TIME: 17:00
2/15/07 AP February 15, 2007 11:42:17 AM glsouth.
B125 01 7/27/07 JGM BLDG, FINAL TIME: 17:00
7/27/07 DP July 26, 2007 3:48:03 PM acarter.
07/27/2007 04:17 PM JGM PDA
step into garage exceeds maximum height
"B725 02 7/ 1/0 B BLDG, FINAL TIME: 17:00
July 31, 2007 9:29:23 AM glsouth.
------------------------------------- COMMENTS AND NOTES --------- 7----------------------------fvo
-
(8/6/2007) Kim Wolfe Recalling for C.O for 1501 Bluefield Ct
From: Paul Schoenfeld
To: Amber Carter; Benjamin McCarty; Chris Haver; Gina Southerland; Joe G...
Date: 7/30/2007 8:22 AM
Subject: Re: Calling for C.O. for 1501 Bluefield Ct
All ok.
Paul
>>> Amber Carter 07/27/07 1:43 PM >>>
by #06-3509
Date: 7/27/2007
Inspection Comments for Finals
Permit Year: 6 Permit Number: 3509
Address: 1501 BLUEFIELD CT
Insp.
inspection Type code
p.
Status
Inspection Result Comments
Description
B100
BLDG, FOUNDATION -SLAB
IC
December 7, 2006 4:22:09 PM ncochran.
B100
BLDG, FOUNDATION -SLAB
IC
STRINGS UP. SLAB GROUND INSTALLED.
M100
MECH, ROUGH IN
IC
01/09/2007 03:43 PM RH PDA
M100
MECH, ROUGH IN
IC
Make sure furnace flue has min. 1" from combustibles.
Page 1
Date: 7/31/2007
Inspection Comments for Finals
Permit Year: 6 Permit Number: 3509
Address: 1501 BLUEFIELD CT
Type
Inspection Type Code
si ins
Inspection Result Comments
Description
B100
BLDG, FOUNDATION -SLAB
IC
December 7, 2006 4:22:09 PM ncochran.
B100
BLDG, FOUNDATION -SLAB
IC
STRINGS UP. SLAB GROUND INSTALLED.
B125
BLDG, FINAL
IC
07/27/2007 04:17 PM JGM PDA
B125
BLDG, FINAL
IC
step into garage exceeds maximum height
M100
MECH, ROUGH IN
IC
01/09/2007 03:43 PM RH PDA
M100
MECH, ROUGH IN
IC
Make sure furnace flue has min. 1" from combustibles.
Page 1
WF0852398 /
001 City of College
Station
PAGE 1
REQ. DATE:
11/28/06
11/28/06
15:07:00
LOCATION:
1501 BLUEFIELD CT
LOC ID:
204846
REQUESTOR:
ED FROEHLING
ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
GLSOUTH AUTH. USER:
GLSOUTH
WORK TYPE:
ROUT
SWR 4"
WTR 3/411
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT
SET
READY
SCHED START:
11/28/06 SCHED
COMPLETION:
11/28/06
********************************************************************************
JOB ORDER RESULT COMTEN'TS
BUILDING PERMIT
CITY OF CQYir�E STATION
1101 TEXAS AVZ
COLLEGE STATION, TX 778,40
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 06-00003509 Date 11/28/06
Property Address . . . . . . 1501 BLUEFIELD CT
Property ID: 569500-1947-0100
R #: R304111
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . SHENANDOAH PH 19
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 143946
Owner Contractor
------------------------ ------------------------
ED FROEHLING BUILDER INC ED FROEHLING BUILDERS
3887 HIGH LONESOME 3887 HIGH LONESOME RD
COLLEGE STATION TX 778459443 COLLEGE STATION TX 77845
(979) 776-8266
--- Structure Information 000 000 SINGLE FAMILY
Construction Type COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info . . . . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 2181.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 3.00
NUMBER OF BEDROOMS 5.00
SEWER TYPE PUBLIC
TAZ 422.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . . GS
Permit Fee . . . . 592.00 Plan Check Fee .00
Issue Date . . . . 11/28/06 Valuation . . . . 143946
Expiration Date . . 5/27/07
Qty Unit Charge Per Extension
BASE FEE 460.00
44.00 3.0000 THOU BLDG, VAL 100001-500000 132.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTERS)
PROVIDE ATTIC ACCESS OPENING (MINIMUM OUGH-F ED SIDLE
BUILDING DEPT REPRESENTATIVE:
APP,LICANT:
BUILDING PERMIT
CITY OF CGiLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 06-00003509
Page 2
Date 11/28/06
Special Notes and Comments
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK DONE N ORDER TO
-------------------------- --- - - -------------
.4
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number
06-00003509
Page 3
Date 11/28/06
Special Notes and Comments
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
.THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
BUILDING DEPT REPRESENTATIVE : _
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page 4
Application Number . . . . . 06-00003509 Date 11/28/06
----------------------------------------------------------------------------
Special Notes and Comments
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES
Narrow Wall Bracing Fully Sheathed with APA Garage Framing
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4" 350.00
WATER TAP 3/4" 400.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
---------------------------------------------------------
Permit Fee Total 592.00 592.00 .00 .00
Plan Check Total .00 .00 .00 .00
Other Fee Total 750.00 750.00 .00 .00
Grand Total 1342.00 1342.00 .00 .00
---------------------------- ----- --- - -
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
APPLICATION FOR BUILDING PERMIT
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
CITY OF COLLEGE STATION WWW.CSTX.GOV
Plannin d De-1- meet C—dret
For Office Use Only
DATE: ( T1lRX�CC REG
APPLICATION #
TEMP POLE #
g P _
ADDRESS/LOCATION: i`501 GOu�T
LOT 10 BLOCK SUBDIVISION �1=N AIA DC>P'44 / SEC/PH�/
BUSINESS/OWNER NAME: C-tomi�C:Ea�It�IC�I�3CflL l� 1 t�C-��PHONE:
CONTRACTOR/HOMEOWNER:lLt7L'HONE:
CONTRACTOR ADDRESS: j,Wj HUC-1 a Rtz) GST-X -7-7 3 A's�
ELECTRICIAN: PLUMBER: _T �, T_->C0 t3'-
HVAC: GOOD CENTS (Residential only):
CLASS OF WORK 1� (:7�14
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION OVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ONLY
DUPLEX (Landscape Plans) REMODEL/RENOVATION* SWIMMING P
TENT/CAW
DESCRIPTION OF WORK:
PROPOSED USE:
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION
VALUATION: $ i3 . oU `� TOTAL AREA: 2
�� (Cost of Labor and Materials) N
11PUBLIC SEWER NUMBER OF BEDROOMS:
SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS:
4" .6
SEWER TAP: INTERIOR WALL TYPE:
SIZE
WATER TAP: 31 " EXTERIOR WALL TYPE:
SIZE
OTHER TAP: FOUNDATION TYPE:
SIZE
TEMP POLE ROOF TYPE:
GARAGE TYPE: SINGLE a DOUBLE I v r TRIPLE
1521G k--
6 LTAC*14
q q- v I
3y . ss
PW41L/
ATTACHED ERr DETACHE F__j CARPORT
SIGNATURE .OF APPLICANT: 1 t1-1k-0- I DIC-p
*If proposed work involves new commercial konstry Ion or facade improv ents/renovations to an existing
commercial property, building elevations are re-lqtrred.
Official Use Only
I-U -4
Plans Examiner
Zoning Official
C ments:
1 (29or NO
41
Fire Marshall
1 0
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor
R value of ductwork
(4
CP /
A/C SEER Rating l2j
ip
t4
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# D _ 3 50 9 DATE:
BUILDING ADDRESS:
/�SD 1 S /Ve Ldai lil"
I. Foundation Requirements
NAJOR
A.
Concrete minimum fc of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier 6 mil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior unless over 60' Ion
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F.
Wood foundation details indicated
MOK
II. Framing: Floor, Wall, Ceiling and Roof Requirements
NA/OA
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
OK
1. One -hour rated extending to roof deck
OK
E.
Header sizes indicated on plans
F.
Emergency bedroom egress
1. Exit direct to outside
2. O enable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
O enable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
N.
O.
P.
Span exceeding code tables must be engineered
Rafter size and spacing and purlin bracing indicated.
Roof covering used.
Indicate Wall Bracing Used for Lateral Bracing
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
II. Framing: Floor, Wall, Ceiling and Roof Requirements continued
NA/
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
S. 18" Overhang allowed on zero lot line construction, perforated soffit allowed.
T. Protected openings on walls < three feet from property line
OK
III. Stairway Requirements
OK
A. Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" diff. max.
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches above handrail
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located four or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four (4) inch sphere
IV. Fireplace Requirements to be indicated onplans)NA/
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must extend at least three (3) feet higher than the highest point where it
projects through the roof of a building & at least two (2) feet higher than any portion of the
building within ten (10) feet horizontal
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
V. Electrical Service Requirements
N
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
VI. Plumbing Requirements
N
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
N K
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
NA/
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N
Maximum drive width for residence is 25' combined for circular 12' minimum
Minimum 20 feet from driveway to side(intersecting) street
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
N
Does not block any water course or divert any flow
Elevation certificate needed
K
PLANS EXAMINER DATE
�q'V, i,. LJUG. V IGHIr VlcGiu.re ro'ane .tng/Surveying, N., [l010 K 1/ 1
r .
Lot 10 Bock 47.durg
I
s
6d fro1�05.
00
I
of `o � I � :'.
I � Y i/ ,s • .
tAL
I
ll��jj11
� I
OCj
..... tov. 0
`
20
IIh
/ �!/
I
a ,
��
a
B.S.L
f�'
1501 vfieW O wet
!!oi
4�
-tt
/ + / �& I.
,,�4 . � '
I
10, Blook 471
I
10' P.U.E.
—J
_ Y
Al 445i34w W - 62.64' —
Decatur Dn*ve
70' R.D.W. — 40' Pavement
Ye% 5709, Rp 200
Scale: 1" 30'
Q ss
\t
REScheck Compliance Certificate
2000 IECC
RES check Software Version 3.5 Release lb
Data filename: C:\Program Files\Check\REScheck\1501BF.rck
TITLE: 1501 BLUEFIELD
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 11 / 17/06
DATE OF PLANS: SEPT 4, 2004
PROJECT INFORMATION:
SPEC
COMPANY INFORMATION:
ED FROEHLING BUILDER, INC
NOTES:
NARROW 5-BED WITH ALLEY GARAGE
COMPLIANCE: Passes
Maximum UA = 715
Your Home UA = 552
22.8% Better Than Code (UA)
Maximum SHGC = 0.40
Your SHGC = 0.35
Ceiling 1: Flat Ceiling or Scissor Truss
Wall 1: Wood Frame, 16" o.c.
Window 1: Metal Frame:Double Pane with Low-E
SHGC: 0.40
Bldg. faces 90 deg. from North; Comp. orient.: Front
Projection factor: 0.23
Door 1: Solid
Wall 2: Wood Frame, 16" o.c.
Window 2: Metal Frame:Double Pane with Low-E
SHGC: 0.40
Bldg. faces 90 deg. from North; Comp. orient.: Left Side
Projection factor: 0.27
Wall 3: Wood Frame, 16" o.c.
Window 3: Metal Frame:Double Pane with Low-E
SHGC: 0.40
Permit Number
Checked By/Date
Gross
Glazing
Area or
Cavity
Cont.
or Door
Perimeter
R-Value
R-Value
U-Factor UA
2181
30.0
0.0
76
471
15.0
0.0
28
93
0.600 56
20 0.400 8
415 15.0 0.0 30
31 0.600 19
367 15.0 0.0 24
40 0.600 24
Bldg. faces 90 deg. from North; Comp. orient.: Back
Projection factor: 0.27
Door 2: Glass 18 0.580 10
SHGC: 0.78
Bldg. faces 90 deg. from North; Comp. orient.: Back
Projection factor: 1.02
Wall 4: Wood Frame, 16" o.c. 425 15.0 0.0 29
Window 4: Metal Frame:Double Pane with Low-E 43 0.600 26
SHGC: 0.40
Bldg. faces 90 deg. from North; Comp. orient.: Right Side
Projection factor: 0.27
Floor 1: Slab-On-Grade:Unheated 213 0.0 222
Insulation depth: 0.0'
Air Conditioner 1: Electric Central Air, 13 SEER
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications,
and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC
requirements in REScheckVersion 3.5 Release lb (formerly MECchec.� and to comply with the mandatory requirements listed in
the RES checkInspection Checklist.
Builder/Designer ��Date t