Loading...
HomeMy WebLinkAboutRES2006-03509r PREPARED 7/31/07, 12:10:07 INSPECTION TICKET PAGE 1 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 7/31/07 ------------------------------------------------------------------------------------------------ ADDRESS . : 1501 BLUEFIELD CT SUBDIV: SHENANDOAH PH 19 CONTRACTOR ED FROEHLING BUILDERS PHONE (979) 776-8266 OWNER ED FROEHLING BUILDER INC PHONE PARCEL 569500-1947-0100 APPL NUMBER: 06-00003509 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT_ BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 12/07/06 RH BLDG, FOUNDATION -SLAB TIME: 17:00 12/07/06 AP December 7, 2006 10:47:01 AM glsouth. December 7, 2006 4:22:09 PM ncochran. STRINGS UP. SLAB GROUND INSTALLED. B115 01 2/09/07 OC BLDG, FRAMING TIME: 17:00 2/09/07 AP February 5, 2007 3:34:40 PM ncochran. B130 01 2/15/07 RH BLDG, INSULATION TIME: 17:00 2/15/07 AP February 15, 2007 11:42:17 AM glsouth. B125 01 7/27/07 JGM BLDG, FINAL TIME: 17:00 7/27/07 DP July 26, 2007 3:48:03 PM acarter. 07/27/2007 04:17 PM JGM PDA step into garage exceeds maximum height "B725 02 7/ 1/0 B BLDG, FINAL TIME: 17:00 July 31, 2007 9:29:23 AM glsouth. ------------------------------------- COMMENTS AND NOTES --------- 7----------------------------fvo - (8/6/2007) Kim Wolfe Recalling for C.O for 1501 Bluefield Ct From: Paul Schoenfeld To: Amber Carter; Benjamin McCarty; Chris Haver; Gina Southerland; Joe G... Date: 7/30/2007 8:22 AM Subject: Re: Calling for C.O. for 1501 Bluefield Ct All ok. Paul >>> Amber Carter 07/27/07 1:43 PM >>> by #06-3509 Date: 7/27/2007 Inspection Comments for Finals Permit Year: 6 Permit Number: 3509 Address: 1501 BLUEFIELD CT Insp. inspection Type code p. Status Inspection Result Comments Description B100 BLDG, FOUNDATION -SLAB IC December 7, 2006 4:22:09 PM ncochran. B100 BLDG, FOUNDATION -SLAB IC STRINGS UP. SLAB GROUND INSTALLED. M100 MECH, ROUGH IN IC 01/09/2007 03:43 PM RH PDA M100 MECH, ROUGH IN IC Make sure furnace flue has min. 1" from combustibles. Page 1 Date: 7/31/2007 Inspection Comments for Finals Permit Year: 6 Permit Number: 3509 Address: 1501 BLUEFIELD CT Type Inspection Type Code si ins Inspection Result Comments Description B100 BLDG, FOUNDATION -SLAB IC December 7, 2006 4:22:09 PM ncochran. B100 BLDG, FOUNDATION -SLAB IC STRINGS UP. SLAB GROUND INSTALLED. B125 BLDG, FINAL IC 07/27/2007 04:17 PM JGM PDA B125 BLDG, FINAL IC step into garage exceeds maximum height M100 MECH, ROUGH IN IC 01/09/2007 03:43 PM RH PDA M100 MECH, ROUGH IN IC Make sure furnace flue has min. 1" from combustibles. Page 1 WF0852398 / 001 City of College Station PAGE 1 REQ. DATE: 11/28/06 11/28/06 15:07:00 LOCATION: 1501 BLUEFIELD CT LOC ID: 204846 REQUESTOR: ED FROEHLING ORIGIN: CUSTOMER -WALK IN REQ. USER: GLSOUTH AUTH. USER: GLSOUTH WORK TYPE: ROUT SWR 4" WTR 3/411 ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 11/28/06 SCHED COMPLETION: 11/28/06 ******************************************************************************** JOB ORDER RESULT COMTEN'TS BUILDING PERMIT CITY OF CQYir�E STATION 1101 TEXAS AVZ COLLEGE STATION, TX 778,40 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 06-00003509 Date 11/28/06 Property Address . . . . . . 1501 BLUEFIELD CT Property ID: 569500-1947-0100 R #: R304111 Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . SHENANDOAH PH 19 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 143946 Owner Contractor ------------------------ ------------------------ ED FROEHLING BUILDER INC ED FROEHLING BUILDERS 3887 HIGH LONESOME 3887 HIGH LONESOME RD COLLEGE STATION TX 778459443 COLLEGE STATION TX 77845 (979) 776-8266 --- Structure Information 000 000 SINGLE FAMILY Construction Type COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 2181.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 3.00 NUMBER OF BEDROOMS 5.00 SEWER TYPE PUBLIC TAZ 422.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . GS Permit Fee . . . . 592.00 Plan Check Fee .00 Issue Date . . . . 11/28/06 Valuation . . . . 143946 Expiration Date . . 5/27/07 Qty Unit Charge Per Extension BASE FEE 460.00 44.00 3.0000 THOU BLDG, VAL 100001-500000 132.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTERS) PROVIDE ATTIC ACCESS OPENING (MINIMUM OUGH-F ED SIDLE BUILDING DEPT REPRESENTATIVE: APP,LICANT: BUILDING PERMIT CITY OF CGiLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 06-00003509 Page 2 Date 11/28/06 Special Notes and Comments X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12' ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK DONE N ORDER TO -------------------------- --- - - ------------- .4 BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number 06-00003509 Page 3 Date 11/28/06 Special Notes and Comments ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES .THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING BUILDING DEPT REPRESENTATIVE : _ APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 4 Application Number . . . . . 06-00003509 Date 11/28/06 ---------------------------------------------------------------------------- Special Notes and Comments DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES Narrow Wall Bracing Fully Sheathed with APA Garage Framing ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total 592.00 592.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1342.00 1342.00 .00 .00 ---------------------------- ----- --- - - BUILDING DEPT REPRESENTATIVE: APPLICANT: APPLICATION FOR BUILDING PERMIT 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX CITY OF COLLEGE STATION WWW.CSTX.GOV Plannin d De-1- meet C—dret For Office Use Only DATE: ( T1lRX�CC REG APPLICATION # TEMP POLE # g P _ ADDRESS/LOCATION: i`501 GOu�T LOT 10 BLOCK SUBDIVISION �1=N AIA DC>P'44 / SEC/PH�/ BUSINESS/OWNER NAME: C-tomi�C:Ea�It�IC�I�3CflL l� 1 t�C-��PHONE: CONTRACTOR/HOMEOWNER:lLt7L'HONE: CONTRACTOR ADDRESS: j,Wj HUC-1 a Rtz) GST-X -7-7 3 A's� ELECTRICIAN: PLUMBER: _T �, T_->C0 t3'- HVAC: GOOD CENTS (Residential only): CLASS OF WORK 1� (:7�14 ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION OVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ONLY DUPLEX (Landscape Plans) REMODEL/RENOVATION* SWIMMING P TENT/CAW DESCRIPTION OF WORK: PROPOSED USE: HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION VALUATION: $ i3 . oU `� TOTAL AREA: 2 �� (Cost of Labor and Materials) N 11PUBLIC SEWER NUMBER OF BEDROOMS: SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: 4" .6 SEWER TAP: INTERIOR WALL TYPE: SIZE WATER TAP: 31 " EXTERIOR WALL TYPE: SIZE OTHER TAP: FOUNDATION TYPE: SIZE TEMP POLE ROOF TYPE: GARAGE TYPE: SINGLE a DOUBLE I v r TRIPLE 1521G k-- 6 LTAC*14 q q- v I 3y . ss PW41L/ ATTACHED ERr DETACHE F__j CARPORT SIGNATURE .OF APPLICANT: 1 t1-1k-0- I DIC-p *If proposed work involves new commercial konstry Ion or facade improv ents/renovations to an existing commercial property, building elevations are re-lqtrred. Official Use Only I-U -4 Plans Examiner Zoning Official C ments: 1 (29or NO 41 Fire Marshall 1 0 Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork (4 CP / A/C SEER Rating l2j ip t4 PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# D _ 3 50 9 DATE: BUILDING ADDRESS: /�SD 1 S /Ve Ldai lil" I. Foundation Requirements NAJOR A. Concrete minimum fc of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier 6 mil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior unless over 60' Ion 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated MOK II. Framing: Floor, Wall, Ceiling and Roof Requirements NA/OA A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex OK 1. One -hour rated extending to roof deck OK E. Header sizes indicated on plans F. Emergency bedroom egress 1. Exit direct to outside 2. O enable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. O enable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Exterior wall covering indicated on plans 2. Sheathing indicated on plans 3. Moisture barrier indicated on plans J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans M. N. O. P. Span exceeding code tables must be engineered Rafter size and spacing and purlin bracing indicated. Roof covering used. Indicate Wall Bracing Used for Lateral Bracing PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX II. Framing: Floor, Wall, Ceiling and Roof Requirements continued NA/ P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations S. 18" Overhang allowed on zero lot line construction, perforated soffit allowed. T. Protected openings on walls < three feet from property line OK III. Stairway Requirements OK A. Stairway Details 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" diff. max. 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8 B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches above handrail 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located four or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four (4) inch sphere IV. Fireplace Requirements to be indicated onplans)NA/ A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must extend at least three (3) feet higher than the highest point where it projects through the roof of a building & at least two (2) feet higher than any portion of the building within ten (10) feet horizontal PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX V. Electrical Service Requirements N A. Electrical plan to include: 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location VI. Plumbing Requirements N A. Pressure reducing valve required when water pressure exceeds 80 psi B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) VIII. Energy Requirements N K A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 NA/ Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements N Maximum drive width for residence is 25' combined for circular 12' minimum Minimum 20 feet from driveway to side(intersecting) street Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 N Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 N Does not block any water course or divert any flow Elevation certificate needed K PLANS EXAMINER DATE �q'V, i,. LJUG. V IGHIr VlcGiu.re ro'ane .tng/Surveying, N., [l010 K 1/ 1 r . Lot 10 Bock 47.durg I s 6d fro1�05. 00 I of `o � I � :'. I � Y i/ ,s • . tAL I ll��jj11 � I OCj ..... tov. 0 ` 20 IIh / �!/ I a , �� a B.S.L f�' 1501 vfieW O wet !!oi 4� -tt / + / �& I. ,,�4 . � ' I 10, Blook 471 I 10' P.U.E. —J _ Y Al 445i34w W - 62.64' — Decatur Dn*ve 70' R.D.W. — 40' Pavement Ye% 5709, Rp 200 Scale: 1" 30' Q ss \t REScheck Compliance Certificate 2000 IECC RES check Software Version 3.5 Release lb Data filename: C:\Program Files\Check\REScheck\1501BF.rck TITLE: 1501 BLUEFIELD CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 11 / 17/06 DATE OF PLANS: SEPT 4, 2004 PROJECT INFORMATION: SPEC COMPANY INFORMATION: ED FROEHLING BUILDER, INC NOTES: NARROW 5-BED WITH ALLEY GARAGE COMPLIANCE: Passes Maximum UA = 715 Your Home UA = 552 22.8% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.35 Ceiling 1: Flat Ceiling or Scissor Truss Wall 1: Wood Frame, 16" o.c. Window 1: Metal Frame:Double Pane with Low-E SHGC: 0.40 Bldg. faces 90 deg. from North; Comp. orient.: Front Projection factor: 0.23 Door 1: Solid Wall 2: Wood Frame, 16" o.c. Window 2: Metal Frame:Double Pane with Low-E SHGC: 0.40 Bldg. faces 90 deg. from North; Comp. orient.: Left Side Projection factor: 0.27 Wall 3: Wood Frame, 16" o.c. Window 3: Metal Frame:Double Pane with Low-E SHGC: 0.40 Permit Number Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA 2181 30.0 0.0 76 471 15.0 0.0 28 93 0.600 56 20 0.400 8 415 15.0 0.0 30 31 0.600 19 367 15.0 0.0 24 40 0.600 24 Bldg. faces 90 deg. from North; Comp. orient.: Back Projection factor: 0.27 Door 2: Glass 18 0.580 10 SHGC: 0.78 Bldg. faces 90 deg. from North; Comp. orient.: Back Projection factor: 1.02 Wall 4: Wood Frame, 16" o.c. 425 15.0 0.0 29 Window 4: Metal Frame:Double Pane with Low-E 43 0.600 26 SHGC: 0.40 Bldg. faces 90 deg. from North; Comp. orient.: Right Side Projection factor: 0.27 Floor 1: Slab-On-Grade:Unheated 213 0.0 222 Insulation depth: 0.0' Air Conditioner 1: Electric Central Air, 13 SEER COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in REScheckVersion 3.5 Release lb (formerly MECchec.� and to comply with the mandatory requirements listed in the RES checkInspection Checklist. Builder/Designer ��Date t