Loading...
HomeMy WebLinkAboutRES2006-03486, 06-3488_ ._84_ —au� c, PREPARED 6/04/07, 8:54:57 INSPECTION TICKET PAGE 1 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 6/04/07 ------------------------------------------------------------------------------------------------ ADDRESS 3901 BRIDGEBERRY CT SUBDIV: WESTFIELD VILLAGE PH 4 CONTRACTOR STYLECRAFT BUILDERS PHONE (979) 690-1222 OWNER . . PHONE PARCEL . . 005401-0409-0010 APPL NUMBER: 06-00003486 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 12/14/06 OC BLDG, FOUNDATION -SLAB TIME: 17:00 12/14/06 AP December 13, 2006 12:55:11 PM kwolfe. Strings On Setbacks O.K. Slab Ground Installed B115 01 2/12/07 OC BLDG, FRAMING TIME: 17:00 2/12/07 AP February 12, 2007 8:41:02 AM glsouth. B130 01 2/13/07 OC BLDG, INSULATION TIME: 17:00 2/13/07 AP February 13, 2007 10:54:38 AM kwolfe. B132 01 2/16/07 RH BLDG, SHEETROCK FASTENER TIME: 17:00 2/16/07 AP February 16, 2007 11:00:46 AM ncochran. B-125.01 6 04/ 7 B BLDG, FINAL TIME: 17:00 June 4, 2007 8:52:32 AM glsouth. -----r-------------------�--------- COMMENTS AND NOTES -------------------------------------- A[, e-z_-,_ Date: 6/4/2007 Inspection Comments for Finals Permit Year: 6 Permit Number: 3486 Address: 3901 BRIDGEBERRY CT Insp. s . YP Inspection Type Code status Inspection Result Comments Description B100 BLDG, FOUNDATION -SLAB IC Strings On Setbacks O.K. B100 BLDG, FOUNDATION -SLAB IC Slab Ground Installed P100 PLBG, ROUGH IN IC December 6, 2006 4:29:57 PM kwolfe. Page 1 WF0860140 / 001 City of College Station PAGE 1 REQ. DATE: 12/27/06 © ks,' 12/27/06 11:26:26 LOCATION: 3901 BRIDGEBERRY CT LOC ID: 203736 REQUESTOR: STYLECRAFT BUILDERS ORIGIN:.* CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT TEMP POLE PASSED ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 12/27/06 SCHED COMPLETION: 12/27/06 ******************************************************************************** JOB ORDER RESULT COMMENTS WFO852044 / 001 City of Colleg,Q Station PAGE 1 REQ. DATE: 11/27/06 11/27/06 14:55:00 LOCATION: 3901 BRIDGEBERRY CT LOC ID: 203736 REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT 4" SWR TAP 3/4" WTR TAP TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 11/27/06 SCHED COMPLETION: 11/27/06 ******************************************************************************** JOB ORDER RESULT COW ENTS I �l Ll ,111 mini a mnR 0 0 .O SHEET INDEX COVER SHEET G-1 SITE PLAN C-1 FLATWORK DETAILS C-2 FOUNDATION PLAN S-1 DIMENSION PLAN S-2 FRAMING PLAN S-3 ROOF FRAMING PLAN S-4 DECKING LAYOUT S-5 -F-RAVING- D ETA] LS-------- -S-6 -- FLOOR PLAN A-1 DETAILS A-2 ELEVATIONS A-3 CABINET LAYOUT A-4 FLOORING PLAN A-5 ELECTRICAL PLAN E-1 sHEsr: G-1 AREA TMMARY N O � > U� a u 50 W 3901 BRIDGEBERRY COURT Q a U WESTFIELD VILLAGE � ���III O LOT - 1 v BLOCK - 9 o a PHASE = 4 a, �4 H � VCD W id FINISHING NOTES f . CEDAR FENCE 2. 3. 4. 5. 6. 1 SITE PLAN SCALE: 1 "=20'-0' 3RIDGEBERRY COURT 'FIELD VILLAGE 1 'K-9 E-4 C-1 k"MyIu_._: 11.0 00 N �\ U Q �a CW7 r--� as W a hoc a O a COO E+ W Q, rn p 6/7/2007) Gina Southerland - Re: Calling for C.O. @ 3901 Bridgeberry Ct. Page 1 From: Terry Boriskie To: banderson@stylecraft-builders.com; Benjamin McCarty; Chris Haver; Gin... Date: 6/7/2007 12:54 PM Subject: Re: Calling for C.O. @ 3901 Bridgeberry Ct. Stylecraft has been notified of the needed repairs. Terry Boriskie City of College Station Residential Plans Examiner 979-764-3744 >>> Paul Schoenfeld 6/7/2007 10:37 am >>> Water ok. Sewer buried flagged where buried. Paul >>> Gina Southerland 6/4/2007 8:57 AM >>> BP# 06-3486 Gina Southerland CSR - Planning & Development Services City of College Station 979-764-3570 www.cstx.00v BUILDING PERMIT CITY OF COLLEGE STATION 1 XAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-35.70 FAX: (979)764-3496 ----------------------------------'------------------------------------------ Application Number . . . . . Property Address . . . Property ID: R #: Application type description Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . Application valuation . . . . Owner 06-00003486. Date 11/27/06 3901 BRIDGEBERRY CT 005401-0409-0010 RESIDENTIAL, 1 UNIT DETACHED NEW WESTFIELD VILLAGE PH 4 RESIDENTIAL PLANNED DEVL HOUSING 75834 Contractor ------------------------ ------------------------ STYLECRAFT BUILDERS 4090 SH 6 S COLLEGE STATION TX 77845 (979) 690-1222 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1149.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC TAZ 405.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . KW Permit Fee . . . . 364.00 Plan Check Fee .00 Issue Date . . . . 11/27/06 Valuation . . . . 75834 Expiration Date . . 5/26/07 Qty Unit Charge Per Extension BASE FEE 260.00 26.00 4.0000 THOU BLDG, VAL 50001-100000 104.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 2211 - ------------------------------------------------ ------ --- --'-- -_------- BUILDING DEPT REPRESENTATIVE: APPLIC BUILDING PERMIT CITY OF COLLEGE STATION 1101 T*XAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 06-00003486 Page 2 Date 11/27/06 Special Notes and Comments X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE DRIVEWAY DISTANCE FROM CORNER: "NO RESIDENTIAL DRIVEWAY SHALL BE CONSTRUCTED WITHIN TWENTY FEET (201) OF THE CORNER OF A STREET INTERSECTION. THIS MEASUREMENT SHALL BE TAKEN FROM THE INTERSECTION OF PROPERTY LINES AT THE CORNER." ALSO NOTHING SHALL BE CONSTRUCTED IN THIS TRIANGLE TO IMPAIR VEHICLE DRIVERS VISION. ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL ,PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12' If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE --------------------------------------------- ------ ------:---------- BUILDING DEPT REPRESENTATIVE: ----- APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1s01 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number 06-00003486 Page 3 Date 11/27/06 Special Notes and Comments RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST ------------------------------------------------- ------ ------------------ BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1i01 TiEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 4 Application Number . . . . . 06-00003486 Date 11/27/06 ---------------------------------------------------------------------------- Special Notes and Comments BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged ---------- Paid Credited Due ------------------------------ ----------------- Permit Fee Total 364.00 364.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1114.00 1114.00 .00 .00 BUILDING DEPT REPRESENTATIVE: Iv - APPLICANT: TEMPORARY POLE PERMIT CITY OF COLLEGE STATION l i 01 T'EXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 06-00003488 Date 11/27/06 Property Address . . . . . . 3901 BRIDGEBERRY CT Property ID: 005401-0409-0010 R #: Application type description TEMP POLE Subdivision Name . . . . . . WESTFIELD VILLAGE PH 4 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 0 Owner Contractor ------------------------ ------------------------ STYLECRAFT BUILDERS 4090 SH 6 S COLLEGE STATION TX 77845 (979) 690-1222 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . KW Permit Fee . . . . 20.00 Issue Date . . . . 11/27/06 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited ------------------------------ Due ----------------- Permit Fee Total ---------- 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 - APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX Xmningd-DnxbpmmrSeruicu WWW.CSTX.GOV ADDRESS/LOCATION: For rofficceeuuse Only DATE lb v �TRCCC REG APPLICATION # V v TEMP POLE # LOT (` BLOCK 01 l SUBDIVISION V 1 L L)kC7E /SEC/PH 4 BUSINESS/OWNER NAME: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120 CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120 CONTRACTOR ADDRESS: 4090 State Highway 6 South . ELECTRICIAN: Brazos Valley Electric PLUMBER: Bass Plumbinq HVAC: Control Temp GOOD CENTS (Residential only): No CLASS OF WORK , ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION * SLAB ONLY DUPLEX (Landscape Plans REMODEURENOVATION* SWIMMING POOL Required) DESCRIPTION OF WORK: Conventional Framing STRUCTURE USE: Single Family Residence HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ N/A VALUATION: $ 7 5 , TOTAL AREA: 15S2) HEATED AREA: I t - 4.9 (Cost of Labor and Materials) QX PUBLIC SEWER SEPTIC/TREATMENT SYSTEM . F -1 SEWER TAP: 4° SIZE OX WATER TAP: %n SIZE OTHER TAP: SIZE TEMP POLE GARAGE TYP.E: SINGLE �1�4I ATTACHED Xa NUMBER OF BEDROOMS: 3 NUMBER OF BATHROOMS: vZ INTERIOR WALL TYPE: Sheet Rock EXTERIOR WALL TYPE: Siding and/or Masonry FOUNDATION TYPE: Slab on Grade ROOF TYPE: Composition DOUBLE © TRIPLE a DETACHED E-1 CARPORT SIGNATURE OF APPLICANT: For Stylecraft *If proposed work involves new commercial nstruction or facade improvements/renovations to an existing commercial property, building elevations are required. eeeeeeeeeeeeeeeeeeeee.♦eeeeeeeeeeeeeeeeeeeeeeeeoeeeeee�eeeeee Official Use Only Plans Examiner 6"x" t4p 940ioning Official J Co meets. S or NO • J 4-1 EneY Compliance Informatz'on % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas)' Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER Rating R13' R30 R19" .40 / .65 / R6 � 13✓ 8 PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# DATE: 1-7-06 BUILDING ADDRESS: 3q o / C* - I. Foundation Requirements NA/ A. Concrete minimum fc of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier 6 mil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior unless over 60' Ion 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated MAYOJLK II. Framing: Floor, Wall, Ceiling and Roof Requirements A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex WOK 1. One -hour rated extending to roof deck K E. Header sizes indicated on plans F. Emergency bedroom egress 1. Exit direct to outside 2. O enable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. O enable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Exterior wall covering indicated on plans 2. Sheathing indicated on plans 3. Moisture barrier indicated on plans J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size and spacing and purlin bracing indicated. O. Roof covering used. P. Indicate Wall Bracing Used for Lateral Bracing PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX II. Framing: Floor, Wall, Ceiling and Roof Requirements continued N P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans - r Q. Tempered Glass required in all hazardous locations S. T. 18" Overhang allowed on zero lot line construction, perforated soffit allowed. Protected openings on walls < three feet from property line N III. Stairway Requirements OK A. Stairway Details 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" diff. max. 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8 B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches above handrail 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located four or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four (4) inch sphere IV. Fireplace Requirements to be indicated onplans) NA/ K A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must extend at least three (3) feet higher than the highest point where it projects through the roof of a building & at least two (2) feet higher than any portion of the building within ten (10) feet horizontal PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX V. Electrical Service Requirements NA/ A. Electrical plan to include: 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location VI. Plumbing Requirements NIA/ft A. Pressure reducing valve required when water pressure exceeds 80 psi B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) VIII. Energy Requirements N O A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 NA/ Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements N Maximum drive width for residence is 25' combined for circular 12' minimum Minimum 20 feet from driveway to side(intersecting) street Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 N Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 N Does not block any water course or divert any flow Elevation certifi ate needed MOK PLA XAMINER DATE 0 REScheck Software Version 3.7.3 �r Compliance Certificate Project Title: Plan # 1149C-WV Report Date: 11/15/06 Data filename: S:\ACAD\Archived\Old REScheck\1149C_3901 Bridgeberry Court.rck Energy Code: 2000 IECC Location: College Station, Texas Construction Type: Single Family Glazing Area Percentage: 14% Heating Degree Days: 1788 Construction Site: Permit Date: 11-15-2006 Owner/Agent: Designer/Contractor: Permit # Permit Date Compliance: Passes Maximum UA: 489 Your Home UA: 4-- OT00oBetter Than God_e (UA)]', Maximum SHGC: 0.40 -0 KGTo—s—sU Cavity Cont. "Glazing UAemblyValue Perimeter, Ceiling 1: Flat Ceiling or Scissor Truss: Ceiling 2: Cathedral Ceiling (no attic): Wall 1: Wood Frame, 16" o.c.: Window 1: Metal Frame, Double Pane with Low-E: SHGC: 0.40 Door 1: Solid: Door 2: Glass: SHGC: 0.40 Floor 1: Slab-On-Grade:Unheated: , Insulation Depth: 0.0' Air Conditioner 2: Electric Central Air: 13 SEER Furnace 2: Forced Hot Air: 80 AFUE 845 30.0 0.0 30 294 19.0 0.0 15 1186 13.0 0.0 81 132 0.650 86 38 0.500 19 33 0.580 19 182 0.0 190 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in REScheck Version 3.7.3 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. ii A t k5 2ccG Builder/Desi er Company Name Da e Project Notes: Previously saved project information: SPEC 3901 Bridgeberry Court College Station, Texas Stylecraft Builders, Inc. 4090 St. Hwy. 6 S. College Station, Texas 77845 Plan # 1149C-WV Page 1 of 1