INSPECTION TICKET PAGE 1
City of
College Station
INSPECTOR: BUILDING INSPECTOR DATE 6/23/08
------------------------------------------------------------------------------------------------
ADDRESS
4307 WHITWICK
PL
SUBDIV: CASTLEGATE SEC 3 PH 2
CONTRACTOR CORDOBA
GROUP, INC
PHONE
OWNER
CORDOBA
GROUP INC
PHONE
PARCEL
184200-2301-01.80
APPL NUMBER: 06-00003452
RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT:
BLDG 00 BUILDING PERMIT
REQUESTED
INSP
DESCRIPTION
TYP/SQ
COMPLETED
RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01
3/06/07
OC
BLDG, FOUNDATION -SLAB TIME: 17:00
3/06/07
AP
March 5, 2007 3:51:21 PM ncochran.
Strings On Setbacks O.K..
Slab Ground Installed /
B115 01
5/29/07
OC
BLDG, FRAMING TIME: 17:00 ✓
5/29/07
AE
May 29, 2007 9:25:40 AM glsouth.
05/29/2007 11:20 AM OC PDA
hangers needed through out upstairs fireplace must be
t
installed by insulation inspection
B130 0�
6/06/07
OC
BLDG, INSULATION TIME: 17:00
j
6/06/07
DP
June 5, 2007 1:32:46 PM kwolfe.
06/06/2007 11:.10 AM OC PDA
still need hangers upstairs .
B13 "02
6/19/07
RH
BLDG, INSULATION TIME: 17:00
6/19/07
DP
June 19, 2007 8:24:37 AM kwolfe.
06/19/2007 04:03 PM RH PDA
Need joist hangers upstairs. Floor joist in front left
room ha been cut in half for a/c duct. Needs to be a
supporting floor joist. Make sure all insulation is
installed and cut to fit properly.
B130 03
8/08/07
JGM
BLDG, INSULATION TIME: 17:00
8/08/07
DP
August 6, 2007 10:51:33 AM kwolfe.
08/08/2007 12:12 PM JGM PDA
need to sheetrock over fireplace, floor joist in front of
fireplace needs to rest on supporting wall minimum 11/211,
need to fix other floor joist proiperly
B130 04
8/09/07
OC
BLDG, INSULATION TIME: 17:00 `• "
8/09/07
AP
August 8, 2007 3:25:48 PM glsouth.
afternoon
B125 01
6/16/08
RH
BLDG, FINAL TIME: 17:00
6/16/08
DP
June 16, 2008 8:39:28 AM ccourt.
Need to post energy requirements in electrical panel. Need
proper depth of insulation throughout attic. Need exterior .
I
type
door for
attic entry
from 2nd floor laundry room.
B125 02 6/23/088 BI
BLDG,
FINAL
TIME: 17:00
Cp'dt% �(JO
June
23, 2008
3:47:33 PM
glsouth.
�T_UESDAYjf
-------------------------------------- COMMENTS AND NOTES--------------------------------------
n
Inspection Inquiry - Results Comments - City of College Station
>f48lCoAMPUBUC SECTOR ($j
NaviUne `gam
Inspection Inquiry - Results Comments
Property ID:
Property address:
Application, structure number.
Permit type, sequence number.
Inspection type, sequence number.
Inspection status, date:
I Y Exit I
5 Cancel
184200-2301-0180
4307 WHITWICK PL
06 00003452 000 000
ELEN 00 NEW ELECTRIC PERMIT
E150 0002 ELEC, FINAL
INSPECTION COMPLETED
6104/08
M
Date: 6/16/2008
Inspection Comments for Final
Permit Year: 6 permit Number: 3452
Address: 4307 WHITWICK PL
Type
Inspection Type Code
Description
Status
Inspection Result Comments
B100
BLDG, FOUNDATION-SL,
IC
Strings On Setbacks O.K.
B100
BLDG, FOUNDATION-SL,
IC
Slab Ground Installed
B115
BLDG, FRAMING
IC
05/29/2007 11:20 AM OC PDA
B115
BLDG, FRAMING
IC
hangers needed through out upstairs . fireplace must be
6115
BLDG, FRAMING
IC
installed by insulation inspection
B130
BLDG, INSULATION
IC
06/06/2007 11:10 AM OC PDA
B130
BLDG, INSULATION
IC
still need hangers upstairs .
B130
BLDG, INSULATION
IC
06/19/2007 04:03 PM RH PDA
B130
BLDG, INSULATION
IC
Need joist hangers upstairs. Floor joist in front left
B130
BLDG, INSULATION
IC
room ha' been cut in half for a/c duct. Needs to be a
B130
BLDG, INSULATION
IC
supporting floor joist. Make sure all insulation is
B130
BLDG, INSULATION
IC
installed and cut to fit properly.
B130
BLDG, INSULATION
IC
08/08/2007 12:12 PM JGM PDA
B130
BLDG, INSULATION
IC
need to sheetrock over fireplace, floor joist in front of
B130
BLDG, INSULATION
IC
fireplace needs to rest on supporting wall minimum 11/2",
B130
BLDG, INSULATION
IC
need to fix other floor joist proiperly
E150
ELEC, FINAL
IC
06/03/2008 11:02 AM BB PDA
E150
ELEC, FINAL
IC
Outlet on front porch and by A/C condenser, not GFI
E150
ELEC, FINAL
IC
protected. Need outlet on island. Closet light in downstairs
E150
ELEC, FINAL
IC
master bath, needs proper clearance from shelf.
E150
ELEC, FINAL
IC
Countertop outlet in downstairs laundry needs to be GFI.
E150
ELEC, FINAL
IC
Bathroom light switch in upstairs bedroom, needs to be Arc
E150
ELEC, FINAL
IC
fault protected. Outlet in front right corner of garage, by
E150
ELEC, FINAL
IC
irrigation, needs to be GFI protected.
E150
ELEC, FINAL
IC
06/04/2008 04:26 PM BB PDA
E150
ELEC, FINAL
IC
Need outlet on island, by final.
M100
MECH, ROUGH IN
IC
05/16/2007 04:22 PM RH PDA
M100
MECH, ROUGH IN
IC
Furnace flue not connected. Need proper grille boxes with
Page 1
Date: 6/16/2008
[nspection Comments for Final,
Permit Year: 6 permit Number: 345'd
Address: 4307 WHITWICK PL
Type
Inspection Type Code
Description
snap.
Inspection Result Comments
M100
MECH, ROUGH IN
IC
side connections on first floor. Bathroom exhaust duct
M100
MECH, ROUGH IN
IC
exceeds 25 ft. Connect all exhaust ducts and terminate
M100
MECH, ROUGH IN
IC
outside attic. Need draftstop at duct chases into attic.
M100
MECH, ROUGH IN
IC
05/22/2007 03:23 PM RH PDA
M100
MECH, ROUGH IN
IC
Make sure screws in furnace flue do not penetrate inner
M100
MECH, ROUGH IN
IC
wall and that there is min. 1" of clearance from
M100
MECH, ROUGH IN
IC
combustibles at roof deck. Connect bath exhaust
M100
MECH, ROUGH IN
IC
understairs electricans had just installed fan.
M110
MECH, FINAL
IC
05/19/2008 05:07 PM RH PDA
M110
MECH, FINAL
IC
Need to finish dryer duct for 2nd floor laundry room by
M110
MECH, FINAL
IC
1building final.
Page 2
WF0878955 / 001 City of College Station PAGE 1
REQ. DATE: 03/06/07 03/06/07 15:02:44
LOCATION: 4307 WHITWICK PL LOC ID: 198076
REQUESTOR: CORDOBA GROUP, INC ORIGIN: CUSTOMER -WALK IN
REQ USER: NCOCHRAN AUTH USER:NCOCHRAN WRK TYPE:
TEMP POLE PASSED
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 03/06/07 SCHED COMPLETION: 03/06/07
********************************************************************************
JOB ORDER RESULT COMMENTS
CJ V
IJ�Y
4
WF0869248 / 001
REQ. DATE: 01/29/07
City of Ge*lege Station
0 ( 10000
PAGE
�J
01/29/07 11:55:41' ;�.:
LOCATION:
4307 WHiTW1CK PL Lug Ili: IJOUib
REQUESTOR:
CORDOBA GROUP, INC ORIGIN: CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT
4"
SWR TAP 3/4" WTR TAP
*******************************************************************************
TASK:
SET UP NEW UTILITY ACCT SET READY
SCHEDISTART:
01/29/07 SCHED COMPLETION: 01/29/07
JOB ORDER
RESULT COMMENTS
a.
/^ f
y
i`
i'
i%ap;
s b'
BUILDING PERMIT
I
CITY OF COLLEGE STATION
TEXAS AVE
-�
COLLEGE STATION,- TX 77840
,
PHONE:
----------------------------------------------------------------------------
(979)764-3570 FAX: (979)764-3496
Application Number
. . . . . 06-00003452
Date 1/26/07
Property Address
. . . . . . 4307 WHITWICK PL
Property ID:
184200-2301-0180
R #:
R115364
Application type description
RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name
. . . . . . CASTLEGATE SEC 3 PH 2
i Property Use . .
. . . . . . RESIDENTIAL
Property Zoning .
. . . . . . PLANNED DEVL HOUSING
Application valuation
i
. . . . 301950
Owner
i------------------------
Contractor
CORDOBA GROUP INC
------------------------
CORDOBA GROUP, INC
1920 W VILLA MARIA
RD 1920 W. VILLA MARIA #301
STE 301
BRYAN
TX 77807
BRYAN
TX 778074858
---I Structure Information
000 000 SINGLE FAMILY
Construction Type
. . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type .
. . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info
. . . . . EXTERIOR WALL TYPE
2*4
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
3.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
4575.00
INTERIOR WALL TYPE
2*4
NUMBER OF BATHROOMS
5.50
NUMBER OF BEDROOMS
5.00
SEWER TYPE
PUBLIC
TAZ
441.00
----------------------------------------------------------------------------
Permit . . . . .
. BUILDING PERMIT
Additional desc
KW
I Permit Fee . . .
. 1066.00 Plan Check Fee
.00
Issue Date . . .
. 1/26/07 Valuation . .
. . 301950
Expiration Date
7/25/07
Qty Unit Charge
Per
Extension
BASE FEE
460. 00 14"a
202.00 3.0000
THOU BLDG, VAL 100001-500000
606.00 d-
----------------------------------------------------------------------------,
Special Notes and
Comments
,
ALL BRANCH CIRCUITS
THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL
BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
----------------------------------------------- ----
I BUILDING DEPT RE S ATIVE:
----------
�
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
i 1101 'TEXAS AVE
COLLEGE STATION, TX 77840
----------------------------------------------------------------------------
PHONE: (979)764-3570 FAX: (979)764-3496
Page 2
+
Application Number 06-00003452 Date 1/26/07
----------------------------------------------------------------------------'
Special Notes and Comments
-
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 2211
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
!
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
Garage ceiling must have 5/8" Type X sheetrock when there
is Habitable space above the garage.
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
j CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
..
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
i WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 2011
front)
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
' RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
;
WITHOUT THE USE OF A KEY,TOOL OR SPEC L KNOWLEDGE/EFFORT
BUILDING DEPT ENTATIVE:
i APPLICANT:
BUILDING PERMIT
i CITY OF COLLEGE STATION
;_101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page 3
i Application Number . . . . . 06-00003452 Date 1/26/07
---------------------------------------------------------------------------
Special Notes and Comments
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
•
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
;44
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
*-
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE..
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120-
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED��,
FENESTRATION PRODUCTS SHALL NOT EXCEED .4.a'
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
=•
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIA E VICINITY OF THE
-------------------------------------------- ------ - --- --'-----------
BUILDING DEPT REPS ATIE
(�
I
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE (979)764-3570 FAX: (979)764-3496
---I-------------
Page
4
Application Number . . . . . 06-00003452 Date
1/26/07 =•
-- -�- --------------------------------------------------------------------,-
Special Notes and Comments
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA.,
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
STAIRS SHALL COMPLY WITH SECTION R-311 (2003 IRC) WITH A
;
CONTINUOUS HANDRAIL OR SECTION
1009 (2003 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL
Al
NEEDED, ENDS SHALL BE RETURNED CR SHALL TERMINATE INTO A
NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDCWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND
LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003
IRC)
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
_•
Narrow Wall Bracing Fully Sheathed Accompanied by an
.,
Engineers Letter for Bay Window Areas.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4"
350.00 �•
WATER TAP 3/4"
400.00 ''ems
Lis
---------------------------------------------------------------------------
Fee summary Charged Paid Credited DueII
----------------------------------------
-----------------
Permit Fee Total 1066.00 1066.00 .00
.00•
Plan Check Total .00 .00 .00
.00 >
Other Fee Total 750.00 750.00 .00
.00
Grand Total 1816.00 1816.00 .00
.00
i
-------------------------------------------- ----- --------------".
1 BUILDING DEPT EPRES NTATI E: _
� APPLICANT:
i
s.
TEMPORARY POLE PERMIT•
CITY OF COLLEGE STATION
i :101 'TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
---'-------------------------------------------------------------------------
i
Application Number . . . . . 06-00003453 Date 1/26/07
Property Address . . . . . . 4307 WHITWICK PL
Property ID: 184200-2301-0180
R #: R115364
Application type description TEMP POLE
Subdivision Name . . . . . . CASTLEGATE SEC 3 PH 2
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . PLANNED DEVL HOUSING a•
Application valuation . . . . 0
Owner
Contractor
r•
CORDOBA GROUP INC
CORDOBA GROUP, INC
j 1920 W VILLA MARIA
RD
1920 W. VILLA MARIA
#301
STE 301
BRYAN
TX 77807
{'
g,
BRYAN
TX 778074858-------------------------------------------------------------------------
Permit . . . . . .
TEMP POLE
PERMIT
Additional desc .
. KW
Permit Fee . . .
. 20.00
Issue Date . . .
. 1/26/07
Valuation . . .
.
0
---'-------------------------------------------------------------------------
Other Fees . . . .
. . . . .
TEMP ELECT POLE CONNECT
45.00
---j-------------------------------------------------------------------------
Fee summary
Charged
----------
Paid Credited
------------------------------
Due
-----------------
Permit Fee Total
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
_
I �P�
I i `w'
s ,
- - Y - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - • - - - - - - - - - -
I
BUILDING DEPT Rip-RHTA,IVE
i
APPLICANT:
APPLICATION FOR BUILDING PERMIT
1101 TEXAS AVENUE
` COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
CITY OF COLLEGE STATION WWW.CSTX.GOV
Planning&.Devdnpm' Srruicrs.
ADDRESS/LOCATION: �+
�s►
LOT �V/BLOCK SUBDIVISION 06R,& ffl:� SEC/PH Z
BUSINESS/OWNER NAME: &joof;�+ 64bOP PNC , PHONE: SWf
DATE: 11_11�TRCC REEGL��j�f
APPLICATION # OU _
TEMP POLE # ao, -
CONTRACTOR/HOMEOWNER: PHONE:
CONTRACTOR ADDRESS: R20 I.t% + V i (1 h MA PA It— 301
ELECTRICIAN: 'R119Z PLUMBER: c C
HVAC: nj M/+i F, 0465 Z GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ONLY
DUPLEX (Landscape Plans) REMODEURENOVATION* SWIMMING POOL
TENT/CANOPY
DESCRIPTION OF WORK: NOW SE opisi\jcc
PROPOSED USE:
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ G 3CA 9 VTOTAL AREA HEATED AREA
(Cost of Labor and Materials)
PUBLIC SEWER
❑r SEPTIC/TREATMENT SYSTEM
Ij
® SEWER TAP:
® WATER TAP:
OTHER TAP:
n TEMP POLE
GARAGE TYPE
`1
SIZE
3 /(�
SIZE
SIZE
SINGLE
ATTACHED a
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
DOUBLE a
DETACHED
2x tI
L-675'_
Z.�
P,, a_ X__ SI,A-r3
S)•tIN�LE� ,
TRIPLE
CARPORT
SIGNATURE OF APPLICANT: `_�
*If proposed work involves new commercial construction or facade improvements/renovations to an existing
commercial property, building elevations are required.
Official Use Only
-Ito -0&
r Plans Examiner
115-1 "AAfWS L�H)e2
Zoning Official
PvnVents:
ES r NO
Fire Marshall
Energy Code Compliance Information
% Glazing of exterior walls 4 IS 0/
Insulation R value of exterior walls j `3 ✓
i
Insulation R value of ceiling 1 (flat areas) 3 0
Insulation R value of ceiling 2 (vaulted areas/no. attic) I ✓
Glazing SHGC •No ✓
Glazing U-Factor
R value of ductwork
A/C SEER Rating - ►� ,
J
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# Q _ Sot DATE: _ _ O ro
BUILDING ADDRESS:
y3o7
r,
I. Foundation Requirements
N
A. Concrete minimum f c of 3000 PSI
B. Minimum four 4 inch slab thickness
C. Vapor barrier 6 mil. Poly min.
D. Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior unless over 60' Ion
3. Spacing of beams does not exceed 15'
E. Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F. Wood foundation details indicated
N
II. Framing: Floor, Wall, Ceiling and Roof Requirements
N
A. Girder or sill dimensions, grade & species
B. Floor joist size, spacing, grade & direction of span indicted on plans
C. Treated sill plate or bottom plate
D. Tenant separation in duplex
OK
1. One -hour rated extending to roof deck
OK
E. Header sizes indicated on plans
F. Emergency bedroom egress
1. Exit direct to outside
2. O enable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G. O enable bathroom window required when mechanical ventilation is not provided
H. Stud grade andspacing
I. Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J. Roof framing Ian or elevation shown
K. Ceiling joist size, spacing, grade and direction of span indicated on plans
L. Attic access location and size indicated on plans
M. Span exceeding code tables must be engineered
N. Rafter size and spacing and purlin bracing indicated.
O. Roof covering used.
P. Indicate Wall Bracing Used for Lateral Bracing
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
II. Framing: Floor, Wall, Ceiling and Roof Requirements continued
NA/
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
S. 18" Overhang allowed on zero lot line construction, perforated soffit allowed.
T. Protected openings on walls < three feet from property line
o
III. Stairway Requirements
A. Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" diff. max.
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches above handrail
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located four or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four (4) inch sphere
IV. Fireplace Requirements to be indicated onplans)
N
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must extend at least three (3) feet higher than the highest point where it
projects through the roof of a building & at least two (2) feet higher than any portion of the
building within ten (10) feet horizontal
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
F�w
V. Electrical Service Requirements
NA/
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
VI. Plumbing Requirements
N
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
NA/
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
N K
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N O
Maximum drive width for residence is 25' combined for circular 12' minimum
Minimum 20 feet from driveway to side(intersecting) street
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
NNqp
Does not block any water course or divert any flow
Elevation cerfificate needed
K ,
AAl
/-
CANS EXAMINER DATE
BERRY ENGINEERING COMPANY
Telephone: 979.696.4000
Cell: 979.575.3457
berTycng@hotmaii.com
Tuesday, January 23, 2007
City of College Station
Building Inspection -Permits
1101 Texas Avenue
College Station, TX 77840
1811 Rose Street
,an, Texas 77802
RE: Proposed New Single Family Home, 4307 Whitwick, College Station, Texas 77840
Dear City Staff:
Per request of City of College Station, Texas Staff, International Residential Code (IRC) is
referenced and included in the opinion and recommendation for the construction of the above
referenced property.
As per review of the documentation and information made available to me, the use of external
structural sheathing to create a diaphragm that strengthens the framing members on the proposed
two-story single family home to be constructed at 4307 Whitwick, College Station, Texas will
provide the necessary support for the anticipated wind load as specified in the International
Residential Code (IRC) Section R301.2.1 and International Building Code (IBC) Section 1609.3
Referencing IBC Table 1609.3.1 and Figure 1609 depict a geographical 3-second wind speed of 90
miles per hour; the same geographical wind speed referenced in IRC Figure R301.2(4). The use of
the sheathing complies with the set of provisions in IBC Section 2305 for Lateral -Force -Resisting
Systems with Design & Construction set -forth, more specifically, in IBC Section 2305.2 for use in
wind -load design for simple diaphragm buildings having flat, gabled or hipped roofs that are less
than 60' (18,288) tall or where the mean roof height does not exceed the shortest horizontal
dimension. In addition, IRC Section R602.10.3, method 3 specifies that wood structural panel
sheathing of 5/16" (8mm) on 16-inch spaced studs meet the requirements for Braced wall panel
construction. In considering the lifting or moving of the building, the attached calculations show
the overturning moment due to wind load is 15.2% of the stabilized moment due to dead load,
substantially less than the not -to -exceed 66.67% as specified in IBC Section 906.1(e).
Also, please note that IRC R301.1.3 state as follows: `Engineered design in accordance with the
International Building Code zr permitted for all buildings and structures, and parts thereof, included in the scope of
this code.
Opinion
Therefore, UPON MY REVIEW OF THE ABOVE REFERENCED INTERNATIONAL
BUILDING CODE AND COMPLIANCE WITH THE RECOMMENDATION OF THE USE
OF EXTERNAL STRUCTURAL SHEATHING ON THE EXTERIOR WALLS, AS RELATED
TO ME AND BY INVESTIGATION, IT IS MY OPINION THAT:
Permitting the proposed construction improvements to the referenced property should be
considered and approved provided the additions and modifications as set forth and referenced in
this report are complied with and construction procedures are performed in a workmanship manner.
Limitations
Berry Engineering Company and principal(s), thereof, agrees to or assumes no responsibility or
liability for any unforeseeable or undisclosed issues or events at the above referenced property. The
opinion(s) expressed in this report are current as of the above date and are limited to matters
expressly stated herein, and no opinions or warranties are implied or inferred beyond the scope of
such matters. Also, this report and any enclosure or attachment are to be considered express
confidential property to be used for the purpose of permitting and approval by the controlling
jurisdiction and shall not be made available to any other party without express written approval.
I appreciated the opportunity to be of service and assist with this request. Please feel free to call me
to discuss any questions you may have concerning the reference included and/or opinion expressed.
L. A. Berry, P. E.
CC: Cordoba Group, Inc. Contractor
FILE: C MRRY ENGTORDOBMUC DLadukHome012307.doc
WIND PRESSURE-SLIDING/OVERTURNING CALCULATIONS
Wind pressure calculation:
P=qf [Cp (windward wall) — Cp (leeward wall)]
where; Cp = 0.8 (www) & Cp = -0.5 (lww)
Brazos County: V30_ya, = 90 mph, of = 20 psf, then qp = 31 psf
P = of [Cp (windward wall) — Cp (leeward wall)
P = 20 psf [(0.8) — (-0.5)]
P= 26 psf
Moment calculations:
n
P,4/ \------------------------ --
A,/ \
Y'
PW41 I -------------
I XfF-----> 1 YW I
Awl Pf
Aft I------------\-V----- --
Ar P, Y, + AW PW YW = Pc (Af Pf Xf)
where; Ar = Area of roof (effective)
AW = Area of wall
Af = Area of floor (slab area)
P, = Pressure on roof (effective)
P, = Pressure on wall
Pf = Pressure on floor
pc = percent (ratio)
A, P, Y, + Aw PW Yw = Pc (Af Pf Xf)
(279.6 ft)(26 lf/ftz)(29 ft) + (1311 ft)(261f/112)(11 ft) = pc (6379 ft2)(20 lf/ft )(30.46 ft)
then;
pc = 0.152 or,
pc = 15.2 %, less than not -to -exceed 66 2/3 %.