HomeMy WebLinkAboutRES2006-03449PREPARED 1/19/07, 8:19:17 INSPECTION TICKET PAGE�g 1 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 1/19/07 ------------------------------------------------------------------------------------------------ ADDRESS . : 3717 DOVE CROSSING LN SUBDIV: DOVE CROSSING PH 2 CONTRACTOR K M CUSTOM HOMES PHONE (979) 589-3739 OWNER . . PHONE PARCEL . . 005401-0206-0020 APPL NUMBER: 06-00003449 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 12/01/06 OC BLDG, FOUNDATION -SLAB TIME: 17:00 12/01/06 AP November 30, 2006 4:13:40 PM glsouth Strings On Setbacks O.K. Slab Ground Installed B115 01 12/15/06 OC BLDG, FRAMING TIME: 17:00 12/15/06 AP December 15, 2006 9:07:27 AM ncochran. B1_30 01 12/18/06 RH BLDG, INSULATION TIME: 17:00 12/18/06 AP December 18, 2006 8:12:46 AM kwolfe. B"25 01 1/19/ 7 BII BLDG, FINAL TIME: 17:00 January 19, 2007 8:13:17 AM glsouth. ------------------------------------ CONTINUED ONTO NEXT PAGE ----------------------------------- �v N 4 i Date: 1 /19/2007 Inspection Comments for Finals Permit Year: 6 Permit Number: 3449 Address: 3717 DOVE CROSSING LN Type Inspection Type Code Sixtus Inspection Result Comments Description B100 BLDG, FOUNDATION -SLAB IC Strings On Setbacks O.K. B100 BLDG, FOUNDATION -SLAB IC Slab Ground Installed E150 ELEC, FINAL IC 01/17/2007 10:52 AM RH PDA E150 ELEC, FINAL IC Need to connect ground wire to ground rod. Exposed plugs E150 ELEC, FINAL IC on countertops. Page 1 WFO851904 / 001 City of College Station PAGE 1 REQ. DATE: 11/27/06 11/27/06 9:58:25 LOCATION: 3717 DOVE CROSSING LN LOC ID: 204508 REQUESTOR: KM CUSTOM HOMES INC ORIGIN: CUSTOMER -WALK IN REQ. USER: NCOCHRAN AUTH. USER: NCOCHRAN WORK TYPE: ROUT 4" SWR TAP 3/4" WTR TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 11/27/06 SCHED COMPLETION: 11/27/06 ******************************************************************************** JOB ORDER RESULT CODU4ENTS City of College Station 110'1 ` IRXAS AVENUE COLLEGE STATION TX 77840 C E R T I F I C A T E O F O C C U P A N C Y P E R M A N E N T Issue Date . . . . . . 1/22/07 Parcel Number . . . . . 005401-0206-0020 Property Address . . . 3717 DOVE CROSSING LN COLLEGE STATION TX 77845 Subdivision Name . . . DOVE CROSSING PH 2 Legal Description . . . DOVE CROSSING PHASE 2 i BLK 6 LOT 2 Property Zoning . . . . SINGLE FAMILY RESIDENTIAL Owner . . . . . . . . . Contractor . . . . . . K M CUSTOM HOMES 979 589-3739 Application number 06-00003449 000 000 Description of Work RESIDENTIAL, 1 UNIT DETACHED NEW Construction type . . . COMBUSTIBLE (UNPROTECTED) Occupancy type . . . . RESIDENTIAL-SFR/DUPLEX Flood Zone . . . . . . Approved . . . . . . . A J& _646101(w- 1ft=*'n.VcL1ng fficial VOID UNLESS SIGNED BY BUILDING OFFICIAL BUILDING PERMIT CITY OF COLLE V STATION 1101 TEXAS AVE COLLEGE STATION --TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 06-00003449 Date 11/27/06 Property Address . . . . . . 3717 DOVE CROSSING LN Property ID: 005401-0206-0020 R #. Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . DOVE CROSSING PH 2 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 170000 Owner Contractor ------------------------ ------------------------ K M CUSTOM HOMES 232 SOUTHWEST PKWY E COLLEGE STATION TX 77840 (979) 589-3739 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1690.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 3.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC TAZ 405.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . NC Permit Fee . . . . 670.00 Plan Check Fee .00 Issue Date . . . . 11/27/06 Valuation . . . . 170000 Expiration Date . . 5/26/07 Qty Unit Charge Per Extension BASE FEE 460.00 70.00 3.0000 THOU BLDG, VAL 100001-500000 210.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT . INTERRUPTERS) PROVIDE ATTIC ACCESS UGH-ZED OPENING (MINIMUM UGH-F ED SIZE 22" -------------------------------------------- --- BUILDING DEPT REF §ENTh;PTVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 2 Application Number . . . . . 06-00003449 Date 11/27/06 ---------------------------------------------------------------------------- Special Notes and Comments X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT -AND WALKWAY PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12' ON NARROW'WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 SI - ----------------------------- -------------f-------------------- -------------- BUILDING DEPT �rPRE„ i iTTIVE : APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 3 Application Number . . . . . 06-00003449 Date 11/27/06 ---------------------------------------------------------------------------- Special Notes and Comments RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. ADD SMOKE DETECTOR(S) PER NOTES ON PLANS Need To Add inside and outside Bedroom #4 SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS -------------------------- ----------_--- ---------/V•------------ BUILDING DEPT ffPRESENNATIVE. APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, 'TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 4 Application Number 06-00003449 Date 11/27/06 ---------------------------------------------------------------------------- Special Notes and Comments TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES Narrow Wall Bracing Fully Sheathed with APA Garage Bracing. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ---------------------------------------- ----------------- Permit Fee Total 670.00 670.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1420.00 1420.00 .00 .00 -------------------------------------------- --- ------------- X BUILDING DEPT�rPRi $�TTATIVE APPLICANT: Fa 0 7c Use Only APPLICATION FOR BUILDING PERMIT DATE: � � G CITY OF COLLEGE STATION ` 1101 TEXAS AVENUE APPLICATION # b COLLEGE STATION, TX 77840nAS3*WA CITY OF COLLEGE STATION (979) 764-3570 (979) 764.3496 FAX TEMP POLE .# Planning 6 Development'Serviaf WWW-CSTX.GOV ADDRESS/LOCATION: ?/� ,U✓C' Cry 551'^j �� i LOT Z- BLOCK �O SUBDIVISION I Z UVC CrBfS/jSEC/PFi BUSINESS/OWNER NAME: PHONE: 7 5 CONTRACTOR/HOMEOWNER: PHONE: CONTRACTOR ADDRESS: o� rt ELECTRICIAN: H��� PLUMPER:y HVAC: Vicert a 'P GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION. RE -ROOF ADDITION OVIN.G SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTIONSLAB ONLY DUPLEX (Landscape Plans REMODEURENOVATION* SWIMMING POOL Required) DESCRIPTION OF WORK: STRUCTURE USE: HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (Ty4S) PROJECT REGISTRATION# EABPRJ G VALUATION: $ / 70e 06 - 7/ TOTAL AREA: 2-3.3 -1 HEATED AREA: (Cost of Labor and Materials) PUBLIC SEWER NUMBER OF BEDROOMS: .0 SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS Q SEWER TAP: ,t L% INTERIOR WALL TYPE: WATER TAP: S E 3�2� (r EXTERIOR WALL TYPE: OTHER TAP: SIZE FOUNDATION TYPE: ® TEMP POLE SIZE ROOF TYPE' GARAGE TYPE: SINGLE D BLE' �RIPLE- ATTACHED DVACF JED a /ICARPORT y 3 SIGNATURE OF APPLICANT: *If proposed work involves new commercial c struc o or Cade improvements/renovations to an existing commercial property, building elevations are required. Ofcial Use Only �. I-1 -o -= F1/' Plans Examiner � -�td� inssde � Av�•s�� 8��1 � Zoning Official 6Tnents: YES or NO 9 J, �l tv 5.kadw wl A4% G Energy Code" Compliance Information % Glazing of exterior walls I q % ✓ Insulation R value of exterior walls 3 Insulation R value of ceiling 1 (flat areas) y insulation R value of. ceiling 2 (vaulted areas/no attic) Glazing SHGC 7 Glazing U-Factor R value of ductwork A/C SEER Rating (S21 Z� PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# 6 _ 3yU DATE: BUILDING ADDRESS: I. Foundation Requirements NAgW A. Concrete minimum fc of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier 6 mil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior unless over 60' Ion 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated OK IL Framing: Floor, Wall, Ceiling and Roof Requirements A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex OK 1. One -hour rated extending to roof deck JqAYOK E. Header sizes indicated on plans jolt F. Emergency bedroom egress 1. Exit direct to outside 2. O enable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. O enable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Exterior wall covering indicated on plans 2. Sheathing indicated on plans 3. Moisture barrier indicated on plans J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size and spacing and purlin bracing indicated. O. Roof covering used. P. Indicate Wall Bracing Used for Lateral Bracing 1. PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX II. Framing: Floor, Wall, Ceiling and Roof Requirements continued N P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations S. 18" Overhang allowed on zero lot line construction, perforated soffit allowed. T. Protected openings on walls < three feet from property line III. Stairway Requirements OK A. Stairway Details 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" diff. max. 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8 B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches above handrail 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located four or more risers above floor/ rade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four (4) inch sphere IV. Fireplace Requirements to be indicated onplans) N A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must extend at least three (3) feet higher than the highest point where it projects through the roof of a building & at least two (2) feet higher than any portion of the building within ten (10) feet horizontal .1 PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX V. Electrical Service Requirements N A. Electrical plan to include: 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location VI. Plumbing Requirements NACM A. Pressure reducing valve required when water pressure exceeds 80 psi B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements NA/OK- A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) VIII. Energy Requirements NAB A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 N Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements N Maximum drive width for residence is 25' combined for circular 12' minimum Minimum 20 feet from driveway to side(intersecting) street Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 NAKW Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 N Does not block any water course or divert any flow Elevation certificate needed MAJOK j4LIL PLAN EXAMINER 1 1-1 6J0b DATE