HomeMy WebLinkAboutRES2006-03449PREPARED 1/19/07, 8:19:17 INSPECTION TICKET PAGE�g 1
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 1/19/07
------------------------------------------------------------------------------------------------
ADDRESS . : 3717 DOVE CROSSING LN SUBDIV: DOVE CROSSING PH 2
CONTRACTOR K M CUSTOM HOMES PHONE (979) 589-3739
OWNER . . PHONE
PARCEL . . 005401-0206-0020
APPL NUMBER: 06-00003449 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 12/01/06 OC BLDG, FOUNDATION -SLAB TIME: 17:00
12/01/06 AP November 30, 2006 4:13:40 PM glsouth
Strings On Setbacks O.K.
Slab Ground Installed
B115 01 12/15/06 OC BLDG, FRAMING TIME: 17:00
12/15/06 AP December 15, 2006 9:07:27 AM ncochran.
B1_30 01 12/18/06 RH BLDG, INSULATION TIME: 17:00
12/18/06 AP December 18, 2006 8:12:46 AM kwolfe.
B"25 01 1/19/ 7 BII BLDG, FINAL TIME: 17:00
January 19, 2007 8:13:17 AM glsouth.
------------------------------------ CONTINUED ONTO NEXT PAGE -----------------------------------
�v
N 4
i
Date: 1 /19/2007
Inspection Comments for Finals
Permit Year: 6 Permit Number: 3449
Address: 3717 DOVE CROSSING LN
Type
Inspection Type Code
Sixtus
Inspection Result Comments
Description
B100
BLDG, FOUNDATION -SLAB
IC
Strings On Setbacks O.K.
B100
BLDG, FOUNDATION -SLAB
IC
Slab Ground Installed
E150
ELEC, FINAL
IC
01/17/2007 10:52 AM RH PDA
E150
ELEC, FINAL
IC
Need to connect ground wire to ground rod. Exposed plugs
E150
ELEC, FINAL
IC
on countertops.
Page 1
WFO851904 / 001 City of College Station
PAGE 1
REQ. DATE:
11/27/06
11/27/06
9:58:25
LOCATION:
3717 DOVE CROSSING LN
LOC ID:
204508
REQUESTOR:
KM CUSTOM HOMES INC ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
NCOCHRAN AUTH. USER: NCOCHRAN
WORK TYPE:
ROUT
4" SWR
TAP 3/4" WTR TAP
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT SET
READY
SCHED START:
11/27/06 SCHED COMPLETION:
11/27/06
********************************************************************************
JOB ORDER
RESULT CODU4ENTS
City of College Station
110'1 ` IRXAS AVENUE
COLLEGE STATION TX 77840
C E R T I F I C A T E O F O C C U P A N C Y
P
E R M A N E N T
Issue Date . . . . . .
1/22/07
Parcel Number . . . . .
005401-0206-0020
Property Address . . .
3717 DOVE CROSSING LN
COLLEGE STATION TX 77845
Subdivision Name . . .
DOVE CROSSING PH 2
Legal Description . . .
DOVE CROSSING PHASE 2
i
BLK 6 LOT 2
Property Zoning . . . .
SINGLE FAMILY RESIDENTIAL
Owner . . . . . . . . .
Contractor . . . . . .
K M CUSTOM HOMES
979 589-3739
Application number
06-00003449 000 000
Description of Work
RESIDENTIAL, 1 UNIT DETACHED NEW
Construction type . . .
COMBUSTIBLE (UNPROTECTED)
Occupancy type . . . .
RESIDENTIAL-SFR/DUPLEX
Flood Zone . . . . . .
Approved . . . . . . .
A J& _646101(w-
1ft=*'n.VcL1ng fficial
VOID UNLESS
SIGNED BY BUILDING OFFICIAL
BUILDING PERMIT
CITY OF COLLE V STATION
1101 TEXAS AVE
COLLEGE STATION --TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 06-00003449 Date 11/27/06
Property Address . . . . . . 3717 DOVE CROSSING LN
Property ID: 005401-0206-0020
R #.
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . DOVE CROSSING PH 2
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 170000
Owner
Contractor
------------------------
------------------------
K M CUSTOM HOMES
232 SOUTHWEST PKWY
E
COLLEGE STATION
TX 77840
(979) 589-3739
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info
EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
1690.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
3.00
NUMBER OF BEDROOMS
4.00
SEWER TYPE
PUBLIC
TAZ
405.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
NC
Permit Fee . . . .
670.00 Plan Check Fee
.00
Issue Date . . . .
11/27/06 Valuation . . .
. 170000
Expiration Date . .
5/26/07
Qty Unit Charge
Per
Extension
BASE FEE
460.00
70.00 3.0000
THOU BLDG, VAL 100001-500000
210.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS
THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
.
INTERRUPTERS)
PROVIDE ATTIC ACCESS
UGH-ZED
OPENING (MINIMUM UGH-F ED SIZE
22"
-------------------------------------------- ---
BUILDING DEPT REF §ENTh;PTVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 2
Application Number . . . . . 06-00003449 Date 11/27/06
----------------------------------------------------------------------------
Special Notes and Comments
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT -AND WALKWAY
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW'WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 SI
-
-----------------------------
-------------f-------------------- --------------
BUILDING DEPT
�rPRE„ i iTTIVE :
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 3
Application Number . . . . . 06-00003449 Date 11/27/06
----------------------------------------------------------------------------
Special Notes and Comments
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
Need To Add inside and outside Bedroom #4
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
-------------------------- ----------_--- ---------/V•------------
BUILDING DEPT ffPRESENNATIVE.
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, 'TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page
4
Application Number 06-00003449
Date
11/27/06
----------------------------------------------------------------------------
Special Notes and Comments
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF
DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL
SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER
HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE
FLOOR IN
PRIVATE GARAGES
Narrow Wall Bracing Fully Sheathed with APA Garage Bracing.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------------------------------
-----------------
Permit Fee Total 670.00 670.00
.00
.00
Plan Check Total .00 .00
.00
.00
Other Fee Total 750.00 750.00
.00
.00
Grand Total 1420.00 1420.00
.00
.00
-------------------------------------------- --- -------------
X
BUILDING DEPT�rPRi $�TTATIVE
APPLICANT:
Fa 0 7c Use Only
APPLICATION FOR BUILDING PERMIT DATE: � � G
CITY OF COLLEGE STATION
` 1101 TEXAS AVENUE APPLICATION # b
COLLEGE STATION, TX 77840nAS3*WA
CITY OF COLLEGE STATION (979) 764-3570 (979) 764.3496 FAX TEMP POLE .#
Planning 6 Development'Serviaf
WWW-CSTX.GOV
ADDRESS/LOCATION: ?/� ,U✓C' Cry 551'^j ��
i
LOT Z- BLOCK �O SUBDIVISION I Z UVC CrBfS/jSEC/PFi
BUSINESS/OWNER NAME: PHONE: 7 5
CONTRACTOR/HOMEOWNER: PHONE:
CONTRACTOR ADDRESS: o� rt
ELECTRICIAN: H��� PLUMPER:y
HVAC: Vicert a 'P GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION. RE -ROOF
ADDITION OVIN.G SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTIONSLAB ONLY
DUPLEX (Landscape Plans REMODEURENOVATION* SWIMMING POOL
Required)
DESCRIPTION OF WORK:
STRUCTURE USE:
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (Ty4S) PROJECT REGISTRATION# EABPRJ G
VALUATION: $ / 70e 06 - 7/ TOTAL AREA: 2-3.3 -1 HEATED AREA:
(Cost of Labor and Materials)
PUBLIC SEWER
NUMBER OF BEDROOMS:
.0 SEPTIC/TREATMENT SYSTEM
NUMBER OF BATHROOMS
Q SEWER TAP:
,t
L%
INTERIOR WALL TYPE:
WATER TAP:
S E
3�2� (r EXTERIOR WALL TYPE:
OTHER TAP:
SIZE
FOUNDATION TYPE:
® TEMP POLE
SIZE
ROOF TYPE'
GARAGE TYPE:
SINGLE
D BLE' �RIPLE-
ATTACHED
DVACF JED a /ICARPORT
y
3
SIGNATURE OF APPLICANT:
*If proposed work involves new commercial c struc o or Cade improvements/renovations to an existing
commercial property, building elevations are required.
Ofcial Use Only
�. I-1 -o
-= F1/' Plans Examiner
� -�td� inssde � Av�•s�� 8��1 �
Zoning Official
6Tnents:
YES or NO
9 J,
�l tv 5.kadw wl A4% G
Energy Code" Compliance Information
% Glazing of exterior walls
I q % ✓
Insulation R value of exterior walls
3
Insulation R value of ceiling 1 (flat areas)
y
insulation R value of. ceiling 2 (vaulted areas/no attic)
Glazing SHGC
7
Glazing U-Factor
R value of ductwork
A/C SEER Rating
(S21 Z�
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# 6 _ 3yU DATE:
BUILDING ADDRESS:
I. Foundation Requirements
NAgW
A. Concrete minimum fc of 3000 PSI
B. Minimum four 4 inch slab thickness
C. Vapor barrier 6 mil. Poly min.
D. Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior unless over 60' Ion
3. Spacing of beams does not exceed 15'
E. Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F. Wood foundation details indicated
OK
IL Framing: Floor, Wall, Ceiling and Roof Requirements
A. Girder or sill dimensions, grade & species
B. Floor joist size, spacing, grade & direction of span indicted on plans
C. Treated sill plate or bottom plate
D. Tenant separation in duplex
OK
1. One -hour rated extending to roof deck
JqAYOK
E. Header sizes indicated on plans
jolt
F. Emergency bedroom egress
1. Exit direct to outside
2. O enable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G. O enable bathroom window required when mechanical ventilation is not provided
H. Stud grade andspacing
I. Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J. Roof framing Ian or elevation shown
K. Ceiling joist size, spacing, grade and direction of span indicated on plans
L. Attic access location and size indicated on plans
M. Span exceeding code tables must be engineered
N. Rafter size and spacing and purlin bracing indicated.
O. Roof covering used.
P. Indicate Wall Bracing Used for Lateral Bracing
1.
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
II. Framing: Floor, Wall, Ceiling and Roof Requirements continued
N
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
S. 18" Overhang allowed on zero lot line construction, perforated soffit allowed.
T. Protected openings on walls < three feet from property line
III. Stairway Requirements
OK
A. Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" diff. max.
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches above handrail
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located four or more risers above floor/ rade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four (4) inch sphere
IV. Fireplace Requirements to be indicated onplans)
N
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must extend at least three (3) feet higher than the highest point where it
projects through the roof of a building & at least two (2) feet higher than any portion of the
building within ten (10) feet horizontal
.1
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
V. Electrical Service Requirements
N
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
VI. Plumbing Requirements
NACM
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
NA/OK-
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
NAB
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N
Maximum drive width for residence is 25' combined for circular 12' minimum
Minimum 20 feet from driveway to side(intersecting) street
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
NAKW
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
N
Does not block any water course or divert any flow
Elevation certificate needed
MAJOK
j4LIL
PLAN EXAMINER
1 1-1 6J0b
DATE