HomeMy WebLinkAboutRES2006-03447, 06-344804 ��
off, - N 8
City of College Station
1101 TEXAS AVENUE
COLLEGE STATION TX 77840
C E R T I F I C A T E O F O C C U P A N C Y
P E R M A N E N T
Issue Date . . . .
Parcel Number . . . . .
Property Address . . .
Subdivision Name
Legal Description . . .
Property Zoning . . . .
Owner . . . . . . . . .
Contractor . . . . .
Application number
Description of Work
Construction type .
Occupancy type . . . .
Flood Zone . . . . . .
Approved . . . . .
Bu(Ading Official
VOID UNLESS SIGNED BY BUILDING OFFICIAL
5/01/07
005401-0209-0170
932 TURTLE DOVE TRL
COLLEGE STATION TX 77845
DOVE CROSSING PH 2
DOVE CROSSING PHASE 2
BLK' 9 LOT 17
SINGLE FAMILY RESIDENTIAL
K M CUSTOM HOMES
979 589-3739
06-00003447 000 000
RESIDENTIAL, 1 UNIT DETACHED NEW
COMBUSTIBLE (UNPROTECTED)
RESIDENTIAL-SFR/DUPLEX
Inspection'- Results., ,Entry, �'
City of College- Station
. ..
ilfSinr � %i�BW 7%1(77iti17V13 SIJ`pFY1711': '
Emailia (. Help
Inspection Results Entry'
;Application number type:
:06,` 00003447 RESIDENTIAL 1 UNIT DETACHED NEUV;
Structure permRs`
Q(10 bob BLDG '0o
Inspection type ssegugnce:
x
6125 0001 BLDG FINAx
Propertgaddress:
932-;TURTLE;pOVE; TRL:
Requestdate time by:
�31O1107 17 00 GSA
In spector IDs
"
OC' N
Resuits`"ie:�,
03/01l2007 i-,.
Resultststatus"I
►
Fina6mspectionflag
Y ��►'`:,
�
x� Edit comments, ::
C J�Dysplay m� spy ion penalties
Point value
1yi
(5/1/2007) Kim Wolfe - Re: Calling for CO a@ 932 Turtle Dove Trl Page 1
From: Terry Boriskie
To: Benjamin McCarty; Chris Haver; Gina Southerland; Joe Garcia; Kim Wol...
Date: 5/1/2007 2:47 PM
Subject: Re: Calling for CO @ 932 Turtle Dove Trl
Contacted Kenny at 587-2275 about the needed repairs.
Terry Boriskie
City of College Station
Residential Plans Examiner
979-764-3744
>>> Mitchell Carson 4/27/2007 8:40 am >>>
SEWER BOX IS BURIED AND NEEDS TO BE RAISED.PLACED A GREEN FLAG AT THE LOCATION ..... MITCH
>>> Kim Wolfe 04/24/07 12:34 PM >>>
Any issues?
BP # 06-3447
Thanks
Kimberly Wolfe, CPS
City of College Station
Planning & Development Services
(979)764-3570
www.cstx.aov
WF0852620 / 001 City of College. Station
PAGE 1
REQ. DATE:
11/29/06
11/29/06
11:10:32
LOCATION:
932 TURTLE DOVE TRL
LOC ID:
204590
REQUESTOR:
KM CUSTOM HOMES ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
GLSOUTH AUTH. USER: GLSOUTH
WORK TYPE:
ROUT
TEMP POLE
PASSED
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT SET
READY
SCHED START:
11/29/06 SCHED COMPLETION:
11/29/06
********************************************************************************
JOB ORDER RESULT COMMENTS 6 � q__�
WFO851899 / 001 City of College Station PAGE 1
u
REQ. DATE:
11/27/06
11/27/06
9:53:20
LOCATION:
932 TURTLE DOVE TRL
LOC ID:
204590
REQUESTOR:
KM CUSTOM HOMES INC ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
NCOCHRAN AUTH. USER: NCOCHRAN
WORK TYPE:
ROUT
4" SWR TAP
3/4" WTR TAP
TASK:
SET UP NEW UTILITY ACCT SET
READY
SCHED START:
11/27/06 SCHED COMPLETION:
11/27/06
********************************************************************************
JOB ORDER RESULT CONIlK=S
BUILDINGS MIT
CITY OF COLLEGE STATION
1101 TEXAS'AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 - FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . 06-00003447 Date 11/27/06
Property Address .. . . 932 TURTLE DOVE TRL
Property ID: 005401-0209-0170
R #.
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . DOVE CROSSING PH 2
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 170000
Owner Contractor
------------------------ ------------------------
K M CUSTOM HOMES
232 SOUTHWEST PKWY E
COLLEGE STATION TX 77840
(979) 589-3739
--- Structure Information 000 000 SINGLE FAMILY
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info . . . . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 1687.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 3.00
NUMBER OF BEDROOMS 4.00
SEWER TYPE PUBLIC
TAZ 405.00
----------------------------------------------------------------------------
Permit. . . . . BUILDING PERMIT
Additional desc . . NC
Permit Fee . . . . 670.00 Plan Check Fee .00
Issue Date . . . . 11/27/06 Valuation . . . . 170000
Expiration Date . . 5/26/07
Qty Unit Charge Per Extension
BASE FEE 460.00
70.00 3.0000 THOU BLDG, VAL 100001-500000 210.00
----------------------------------------- 7----------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTERS)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 2211
-
-------------------------------------------- ------ --•- -'----------
BUILDING DEPT REDPESUi eIVE :
APPLICANT:
BUILDING. PERMw[T
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 2
Application Number 06-00003447 Date 11/27/06
----------------------------------------------------------------------------
Special Notes and Comments
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS D NE IN ORDER TO
----------------------------------------------- ----°- '"—_--------
BUILDING DEPT PIE�PRESEN/kTIVE :
APPLICANT:
BUILDING+PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 06-00003447
Page 3
Date 11/27/06
Special Notes and Comments
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
Add smoke detectors upstairs and inside and outside of
bedroom #4
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS'SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
STAIRS SHALL COMPLY WITH SECTION R-311 (2003 IRC) WITH A
CONTINUOUS HANDRAIL OR SECTION
1009 (2003 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL
NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A
NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
-----------------------------------------1-4 ----x-- - -•-------------
BUILDING DEPT �2,`PRESEN/,TIVE :
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 FAX: (979) 764-3496
----------------------------------------------------------------------------
Page
4
Application Number 06-00003447 Date
11/27/06
----------------------------------------------------------------------------
Special Notes and Comments
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
Narrow Wall Bracing Fully Sheathed with APA Garage Framing
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary Charged "Paid Credited
------------------------------
Due
---------------------------
Permit Fee Total 670.00 670.00 .00
.00
Plan Check Total .00 .00 .00
.00
Other Fee Total 750.00 750.00 .00
.00
Grand Total 1420.00 1420.00 .00
.00
-------------------------------------- - - ---- -- tom' ------------
BUILDING DEPT ��PRESEN7ATIVE:
APPLICANT:
TEMPORARY POLE B,ERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 06-00003448 Date 11/27/06
Property Address . . . . . . 932 TURTLE DOVE TRL
Property ID: 005401-0209-0170
R #.
Application type description TEMP POLE
Subdivision Name . . . . . . DOVE CROSSING PH 2
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 0
Owner Contractor
------------------------ ------------------------
K M CUSTOM HOMES
232 SOUTHWEST PKWY E
COLLEGE STATION TX 77840
(979) 589-3739
----------------------------------------------------------------------------
Permit . . . . . . TEMP POLE PERMIT
Additional desc . . NC
Permit Fee . . . . 20.00
Issue Date . . . . 11/27/06 Valuation . . . . 0
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
---------------------------------------------------------
Permit Fee Total 20.00 20.00 .00 .00
Grand Total 20.00 20.00 .00 .00
-
APPLICANT:
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
` 1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX
Planting 6• Development'Semiaf
WWW.CSTX.GOV
a 017co Use Only
DATE: RQQ REG.
APPLICATION #
TEMP POLE V
ADDRESS/LOCATION: Tr4k 6OuP
LOT l % /BLOCK IVISION SUBD2 boue Crd5sl -� ✓ SEC/PH A Z /
--1 y�j �//7 H
BUSINESS/OWNER NAME: . /'t C� { Its � V PHONE: 5R7-dJ 75-
CONTRACTOR/HOMEOWNER: �J PHONE:
CONTRACTOR ADDRESS: '.3�
ELECTRICIAN: '/r4 /t�QV5 PLUMBER: rt"C o
HVAC: Vadl a -e GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE
ADDITION
DEMOLITION (Asbestos Survey)
DUPLEX (Landscape Plans
Required)
LOCATION
NEW CONSTRUCTION *
REMODEURENOVATION*
DESCRIPTION OF WORK: R Pelts (4t?
STRUCTURE USE:
RE -ROOF
SHELL ONLY
SLAB ONLY
SWIMMING POOL
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STAND__AIlRRD ) PROJECT REGISTRATION# EABPRJ
VALUATION: $ l 7v100 U TOTAL AREA:08 � HEATED AREA: % 65 -7
(Cost of Labor and Materials)
PUBLIC SEWER
SEPTIC/TREATMENT SYSTEM
019'EWER TAP:
- HATER TAP:
OTHER TAP:
Ej TEMP POLE
GARAGE TYPE:
SIZE
SIZE
SIZE
NUMBER OF BEDROOMS
NUMBER OF BATHROOMS
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
SINGLE UBLE TRIPLE'
4
ATTACHED ACHED %RPOR
ED
SIGNATURE OF APPLICANT:
*If proposed work involves new corrimeraal c nstrtacti no/�de improvements/renovations to an existing
commercial property, building elevations ar required.
Official Use Only
'O .
_ Plans Examiner
StIIIILf
Zoning Official
C ments:
ES r NO
4uff 1�?_ 0_"� wl
6
a
S
Energy Code Compliance Information
% Glazing of exterior walls
/o
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
36
Insulation R value of. ceiling 2 (vaulted areas/no attic)
/
Glazing SHGC
iy�
Glazing U-Factor
R value of ductwork
A/C SEER Rating
w4
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# 06 _ 3 yq ,-7 DATE: u _ / (' _p (Q
BUILDING ADDRESS:
9312 hove /%L6i I
I. Foundation Requirements
N
A. Concrete minimum f c of 3000 PSI
B. Minimum four 4 inch slab thickness
C. Vapor barrier 6 mil. Poly min.
D. Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior unless over 60' Ion
3. Spacing of beams does not exceed 15'
E. Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
10K
F. Wood foundation details indicated
II. Framing: Floor, Wall, Ceiling and Roof Requirements
N
A. Girder or sill dimensions, grade & species
B. Floor joist size, spacing, grade & direction of span indicted on plans
C. Treated sill plate or bottom plate
D. Tenant separation in duplex
K
1. One -hour rated extending to roof deck
NOK
E. Header sizes indicated on plans
F. Emergency bedroom egress
1. Exit direct to outside
2. O enable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill hei ht of forty-four 44 inches above finished floor
G. O enable bathroom window required when mechanical ventilation is not provided
H. Stud grade andspacing
I. Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J. Roof framing plan or elevation shown
K. Ceiling joist size, spacing, grade and direction of span indicated on plans
L. Attic access location and size indicated on plans
M. Span exceeding code tables must be engineered
N. Rafter size and spacing and purlin bracing indicated.
O. Roof covering used.
P. Indicate Wall Bracing Used for Lateral Bracing
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
H. Framing: Floor, Wall, Ceiling and Roof Requirements continued
N
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
S. 18" Overhang allowed on zero lot line construction, perforated soffit allowed.
T. Protected openings on walls < three feet from property line
4A/)D K
III. Stairway Requirements
N
A. Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" diff. max.
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches above handrail
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located four or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four (4) inch sphere
IV. Fireplace Requirements to be indicated onplans)
OK
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must extend at least three (3) feet higher than the highest point where it
projects through the roof of a building & at least two (2) feet higher than any portion of the
building within ten (10) feet horizontal
.r
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
V. Electrical Service Requirements
NA/
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
VI. Plumbing Requirements
N
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
N K
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
NAICW
Maximum drive width for residence is 25' combined for circular 12' minimum
Minimum 20 feet from driveway to side(intersecting) street
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
INAXV
Does not block any water course or divert any flow
Elevation certificate needed
OK
J4AN�SLXAMINER DATE