HomeMy WebLinkAboutRES2006-03443, 06-3444a=sue3e-344�( �Fe«p)
.6
WF0850537 / 001 City of Cwllegp Station
PAGE 1
REQ. DATE:
11/17/06
11/17/06
13:08:20
LOCATION:
2705 HORSE HAVEN LN
LOC ID:
205414
REQUESTOR:
OAKWOOD CUSTOM HOME ORIGIN:
CUSTOMER -WALK .IN
REQ. USER:
KWOLFE AUTH. USER: KWOLFE
WORK TYPE:
ROUT
4" SWR TAP
3/4" WTR TAP
TASK:
SET UP NEW UTILITY ACCT SET
READY
SCHED START:
11/17/06 SCHED COMPLETION:
11/17/06
JOB ORDER RESULT COMMENTS
City of"College Station
1101 TEXAS AVENUE
COLLEGE STATION TX 77840
C E R T I F I C A T E O F O C C U P A N C Y
P E R M A-N E N T
Issue Date . . . . . .
Parcel Number . . . . .
Property Address . . .
Subdivision Name . . .
Legal Description . . .
Property Zoning . . . .
Owner . . . . . . . . .
5/15/07
336300-0201-0030
2705 HORSE HAVEN LN
COLLEGE STATION TX 77845
HORSE HAVEN ESTATES PH 2, BLOC
K 1, LOT 3, ACRES 0.21
UNKNOWN
Contractor . . . . . . OAKWOOD CUSTOM HOMES
979 690-1504
Application number 06-00003443 000 000
Description of Work RESIDENTIAL, 1 UNIT DETACHED NEW
Construction type . . . COMBUSTIBLE (UNPROTECTED)
Occupancy type . . . . RESIDENTIAL-SFR/DUPLEX
Flood Zone . . . . . .
Approved .
Building jDfficial
VOID UNLESS SIGNED BY BUILDING OFFICIAL
Date: 4/9/2007
Inspection Comments for Finals
Permit Year: 6 Permit Number: 3443
Address: 2705 HORSE HAVEN LN
Type
Inspection Type Code
status
Inspection Result Comments
Description
B115
BLDG, FRAMING
IC
01/10/2007 11:35 AM JGM PDA
B115
BLDG, FRAMING
IC
need straps on apa, returns are less than 24", need
B115
BLDG, FRAMING
IC
platform for water heater
M110
MECH, FINAL
IC
03/02/2007 10:43 AM RH PDA
M110
MECH, FINAL
IC
House locked.
Page 1
I
2
�
�
�
m
m
co
Z
J
I
—
r+
O
ow
m
39'-1
I
a
bD in
0
ta-
I O —
v 0 ? BL.
i m �
I m
N N 10
cv
20'-0 31'=11
7'-0 `
R=304.89, 2705 HORSEHAVEN LANE
CL=59'
2705 IIORSEIIAVEN LANE
LOT: 3
BLOCK: 1
SECTION: 2
IIORSEIIAVEN ESTATES
COLLEGE STATION, TEXAS
SITE PLAN
SCALE: 1 --30
BUILDER:
OAKWOOD CUSTOM IIOMES GROUP LTD.
0
BUILDING PERMIT
CITY OF COkLE4te STATION
1101 TEXAS AVE
COLLEGE STATION., TX 77840
PHONE: (979)764-3570 `FAX: (979)764-3496
----------------------------------------------------------------------------
Application'Number 06-00003443 Date 11/16/06
Property Address . . . . . . 2705 HORSE HAVEN LN
Property ID: 336300-0201-0030
R #.
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . HORSE HAVEN PH 2
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 121000
Owner Contractor
------------------------ ------------------------
OAKWOOD CUSTOM HOMES-
4060 SH 6 S
COLLEGE STATION TX 77845
(979) 690-1504
--- Structure Information 000 000 SINGLE FAMILY
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info . . . . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 1322.00
INTERIOR WALL TYPE 2X4
NUMBER OF BATHROOMS 2.00
NUMBER OF BEDROOMS 3.00
SEWER TYPE PUBLIC
TAZ 225.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . . KW
Permit Fee . . . . 523.00 Plan Check Fee .00
Issue Date . . . . 11/16/06 Valuation . . . . 121000
Expiration Date . . 5/15/07
Qty Unit Charge Per Extension
BASE FEE 460.00
21.00 3.0000 THOU BLDG, VAL 100001-500000 63.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH- RAMED SIZE 2211
------------------------------------------- -
----- ---- -- --.- - -----
BUILDING DEPT PRj�fTTATIVE :
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE`STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number
06-00003443
Page 2
Date 11/16/06
Special Notes and Comments
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
BUILDING DEPT PRE�,E�ATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE` STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number 06-00003443
Page 3
Date 11/16/06
Special Notes and Comments
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
----------------------------------------------- -----X__
- -- -- --------
BUILDING DEPT PRE N TIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE'STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page
4
Application Number . . . . .
06-00003443 Date
11/16/06
----------------------------------------------------------------------------
Special Notes and Comments
ALL PLUMBING, ELECTRICAL, AND
HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS
PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES
Narrow Wall Bracing Fully Sheathed with APA Garage Framing
----------------------------------------------------------------------------
Other Fees . . . . . . . . .
SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary Charged
----------
Paid Credited Due
------------------------------
-----------------
Permit Fee Total 523.00
523.00 .00
.00
Plan Check Total .00
.00 .00
.00
Other Fee Total 750.00
750.00 .00
.00
Grand Total 1273.00
1273.00 .00
.00
BUILDING DEPT EPRES TATIVE:
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 06-00003444 Date 11/16/06
Property Address . . . . . . 2705 HORSE HAVEN LN
Property ID: 336300-0201-0030
R #•
Application type description TEMP POLE
Subdivision Name . . . . . . HORSE HAVEN PH 2
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 0
Owner
Contractor
------------------------
------------------------
OAKWOOD CUSTOM HOMES
4060 SH 6 S
COLLEGE STATION
TX 77845
(979) 690-1504
----------------------------------------------------------------------------
Permit . . . . .
. TEMP POLE
PERMIT
Additional desc .
. KW
Permit Fee . . .
. 20.00
Issue Date . . .
. 11/16/06
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary
Charged
----------
Paid Credited
------------------------------
Due
-----------------
Permit Fee Total
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
BUILDING DEPT PRESE ATIVE:
APPLICANT:
�51
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 S AVENUE
COLLEGESTATION, TX 77840
CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX
Planning d Development Services
WWW.CSTX.GOV
ADDRESS/LOCATION: 2705 HORSE HAVEN LANE
LOT _3 ✓ BLOCK 1 SUBDIVISION _HORSE HAVEN LANE
SEC/PH 2
11/t5NU
DATE: TRCC REG(,j[�
APPLICATION # l l
TEMP POLE # l 1lY `
BUSINESS/OWNER NAME: ALTON OFCZARZAK PHONE 979-690-1504
CONTRACTOR/HOMEOWNER: OAKWOOD CUSTOM HOMEBUILDERS PHONE:979-690-1504
CONTRACTOR ADDRESS: 4060 HIGHWAY 6 SOUTH COLLEGE STATION, TEXAS 77845
ELECTRICIAN: CAMPISE ELECTRIC PLUMBER: AGGILAND PLUMBING
HVAC: THREE RIVERS
_ GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION * SLAB ONLY
DUPLEX (Landscape Plans REMODEURENOVATION* SWIMMING POOL
Required)
DESCRIPTION OF WORK: NEW CONSTRUCTION
STRUCTURE USE: SINGLE FAMILY RESIDENTIAL
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD AS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ I Z 1, - `� TOTAL AREA:SS)?99 HEATED AREA:2= a 7-1-
(Cost of Labor and Materials)
QX PUBLIC SEWER
❑ SEPTIC/TREATMENT SYSTEM
QX SEWER TAP:
FX WATER TAP:
I n�M OTHER TAP:
l� ' ❑ TEMP POLE
n GARAGE TYPE
h�
4' SIZE
SIZE
SIZE
SINGLE
ATTACHED �X
NUMBER OF BEDROOMS: 'A 3
NUMBER OF BATHROOMS: a Z_
INTERIOR WALL TYPE: 2X4 @ 16
EXTERIOR WALL TYPE: 2X4 @ 16 W/ BRICK
FOUNDATION TYPE: SLAB & BEAM
ROOF TYPE: 25 YR COMP.
DOUBLE EX TRIPLE 0
DETACHED F__j CARPORT E]
SIGNATURE OF APPLICANT:
*If proposed work involves new commercial construction or facade improvements/renovations to an existing
commercial property, building elevations are required.
Official Use Only
/ -r-w /— o b i Q-E-Dor NO
T G4,'A�x WIN
- 'CV11y S4-'� wl AP 4 64x4r
IvC
Plans Examiner
Zoning Official
Energy Code Compliance Information
% Glazing of exterior walls 12% /
Insulation R value of exterior walls R13
Insulation R value of ceiling 1 (flat areas) R30
Insulation R value of ceiling 2 (vaulted areas/no attic) R19�
Glazing SHGC .30
Glazing U-Factor .54 l
R value of ductwork R6 /
A/C SEER Rating 14 /
e
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER#
BUILDING ADDRESS:
D 5 Rse. enl �/
I. Foundation Requirements
N
A. Concrete minimum fc of 3000 PSI
B. Minimum four 4 inch slab thickness
C. Vapor barrier 6 mil. Poly min.
D. Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior unless over 60' Ion
3. Spacing of beams does not exceed 15'
E. Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F. Wood foundation details indicated
NAIOIK
II. Framing: Floor, Wall, Ceiling and Roof Requirements
NA/
A. Girder or sill dimensions, grade & species
B. Floor joist size, spacing, grade & direction of span indicted on plans
C. Treated sill plate or bottom plate
D. Tenant separation in duplex
OK
1. One -hour rated extending to roof deck
MOK
E. Header sizes indicated on plans
F. Emergency bedroom egress
1. Exit direct to outside
2. O enable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G. O enable bathroom window required when mechanical ventilation is not provided
H. Stud grade andspacing
I. Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J. Roof framing Ian or elevation shown
K. Ceiling joist size, spacing, grade and direction of span indicated on plans
L. Attic access location and size indicated on plans
M. Span exceeding code tables must be engineered
N. Rafter size and spacing and purlin bracing indicated.
O. Roof covering used.
P. Indicate Wall Bracing Used for Lateral Bracing
s
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
II. Framing: Floor, Wall, Ceiling and Roof Requirements continued
N
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
S. 18" Overhang allowed on zero lot line construction, perforated soffit allowed.
T. Protected openings on walls < three feet from property line
K
III. Stairway Requirements
OK
A. Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" diff. max.
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches above handrail
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located four or more risers above floor/cirade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four (4) inch sphere
IV. Fireplace Requirements to be indicated onplans)
OK
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must extend at least three (3) feet higher than the highest point where it
projects through the roof of a building & at least two (2) feet higher than any portion of the
building within ten (10) feet horizontal
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
V. Electrical Service Requirements
NA/
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
VI. Plumbing Requirements
NA/
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units)
T
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
NAB
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
NA/
Maximum drive width for residence is 25' combined for circular 12' minimum
Minimum 20 feet from driveway to side(intersecting) street
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
NA/
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
NA/
Does not block any water course or divert any flow
Elevation certificate needed
OK
LANS EXAMINER DATE
CREScheck Software Version 3.7.3
Nfj Compliance Certificate
Project Title: HORSEHAVEN LOT 3, BLK 1, PH2
Report Date: 11/13/06
Data filename: G.\OAK_DWG\HORSE HAVEN\HH-Lot34Brookbanklhh3-2705-horsehavenlane.rck
Energy Code: 2003 IECC
Location: College Station, Texas
Construction Type: Single Family
Glazing Area Percentage: 17%
Heating Degree Days: 1788
Construction Site:
2705 HORSEHAVEN LANE
College Sataion, TX 77845
Permit #
Permit Date
Owner/Agent:
Designer/Contractor:
ALTON OFCZARZAK
David Park
OAKWOOD CUSTOM HOMES GROUP
OAKWOOD CUSTOM HOMES GROUP
LTD.
LTD. HOME PLAN DESIGN SERVICE
4060 HWY. 6 SOUTH
4060 Highway 6 South
COLLEGE STATION, TX 77845
College Station, TX 77845
979-690-1504
979-690-1504
PLANS@OAKCHB.COM
plans@oakchb.com
:on-1ulan_ce: Passes Maximum UA: 5811 Your Home UA: 49_4 --> 1 S_.0 %Better Than Code (UA�I
Maximum SHGC: i • i 0.30
Ceiling 1: Flat Ceiling or Scissor Truss:
1094 0.0
30.0
34
Ceiling 2: Cathedral Ceiling (no attic):
219 19.0
0.0
11
Wall 1: Wood Frame, 16" o.c.:
1558 13.0
0.0
101
3050 X8: Metal Frame:Double Pane with Low-E:
120
0.540
65
SHGC: 0.30
1010X3: Metal Frame:Double Pane with Low-E:
3
0.540
2
SHGC: 0.30
4060: Metal Frame:Double Pane with Low-E:
24
0.540
13
SHGC: 0.30
3050 X8 copy 1: Metal Frame:Double Pane with Low-E:
120
0.540
65
SHGC: 0.30
3068 FRONT DOOR: Solid:
20
0.140
.3
2868 BACK DOOR: Solid:
18
0.140
3
2868 TO GARAGE: Solid:
18
0.140
3
CONC. SLAB: Slab-On-Grade:Unheated: , Insulation Depth: 0.0'
186
0.0
194
Heat Pump 1: Air Source: 7.7 HSPF, 14 SEER
Air Conditioner 1: Electric Central Air. 14 SEER
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2003 IECC requirements in
REScheck Version 3.7.3 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
N r-3
Builder/Designer Company Name Date
Project Notes:
HORSEHAVEN LOT 3, BILK 1, PH2
Page 1 of 5
LOT 2, BLOCK 1, PHASE 2 HORSEHAVEN ESTATES
2703 HORSEHAVEN LANE
BROOKBANK
HORSEHAVEN LOT 3, BLK 1, PH2 Page 2 of 5
ciREScheck Software Version 3.7.3
'�( Inspection Checklist
Date: 11 /13/06
Ceilings:
❑ Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 continuous insulation
Comments:
❑ Ceiling 2: Cathedral Ceiling (no attic), R-19.0 cavity insulation
Comments:
Above -Grade Walls:
❑ Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation
Comments:
Windows:
❑ 3050 X8: Metal Frame:Double Pane with Low-E, U-factor. 0.540
For windows without labeled U factors, describe features:
#Panes Frame Type Thermal Break? Yes No
Comments-
❑ 1010X3: Metal Frame:Double Pane with Low-E, U-factor: 0.540
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
❑ 4060: Metal Frame:Double Pane with Low-E, U-factor. 0.540
For windows without labeled U-factors, describe features:
Wanes Frame Type Thermal Break?
Comments:
❑ 3050 X8 copy 1: Metal Frame:Double Pane with Low-E, U-factor: 0.54(
For windows without labeled U-factors, describe features:
Wanes Frame Type Thermal Break?
Comments:
Doors:
❑ 3068 FRONT DOOR: Solid, U-factor: 0.140
Comments:
Q 2868 BACK DOOR: Solid, U-factor: 0.140
Comments:
❑ 2868 TO GARAGE: Solid, U-factor. 0.140
Comments:
Floors:
❑ CONC. SLAB: Slab-On-Grade:Unheated, R-0 (uninsulated)
Comments:
Heating and Cooling Equipment:
❑ Heat Pump 1: Air Source: 7.7 HSPF, 14 SEER or higher
Make and Model Number:
❑ Air Conditioner 1: Electric Central Air. 14 SEER or higher
Make and Model Number,
HORSEHAVEN LOT 3, BLK 1, PH2
Yes No
Yes No
Page 3 of 5
Solar Heat Gain Coefficient:
❑ The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values must be
determined in accordance with the NFRC test procedure or taken from the default table.
Air Leakage:
❑ Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed.
❑ Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from
combustible materials. If non -IC rated, the fixture must be installed with a 3" clearance from insulation.
Skylights:
❑ Minimum insulation requirement for skylight shafts equal to or greater than 12 inches is R-13.
Materials Identification: .
❑ Materials and equipment must be installed in accordance with the manufacturer's installation Instructions.
❑ Materials and equipment must be identified so that compliance can be determined.
❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided.
❑ Insulation R-values, glazing U-factors, and cooling equipment efficiency must be clearly marked on the building plans or
specifications.
Duct Insulation:
❑ Supply ducts in unconditioned attics or outside the building must be insulated to R-8.
❑ Return ducts in unconditioned attics or outside the building must be insulated to R4.
❑ Supply ducts in unconditioned spaces must be insulated to R-6.
❑ Return ducts in unconditioned spaces (except basements) must be insulated to R-2.
❑ Where exterior walls are used as plenums, the wall must be insulated to R-8.
❑ Insulation is not required on return ducts in basements.
Duct Construction:
❑ Dud connections to flanges of air distribution system equipment must be sealed and mechanically fastened.
❑ All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives),
mastic -plus -embedded -fabric, or tapes. Tapes and mastics must be rated UL 181A or UL 181B.
Exception: Continuously welded and locking -type longitudinal joints and seams on duds operating at less than 2 in. w.g. (500
Pa).
❑ The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
❑ Thermostats are required for each separate HVAC system. A manual or automatic mans to partially restrict or shut off the
heating and/or cooling input to each zone or floor shall be provided.
Service Water Heating:
❑ Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral
heat trap or is part of a circulating system.
❑ Insulate circulating hot water pipes to the levels in Table 1.
Circulating Hot Water Systems:
❑ Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
❑ All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the treating energy is from
non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
❑ HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F must be insulated to the levels in Table
HORSEHAVEN LOT 3, BLK 1, PH2 Page 4 of 5
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes
Insulation Thickness In Inches by Pipe Sizes
Non -Circulating Runouts
Circulating Mains and Runouts
Heated Water
Temperature ("F)
Up to 1"
Up to 1.25"
1.5" to 2.0"
Over 2"
170-180
0.5
1.0
1.5
2.0
140-169
0.5
0.5
1.0
1.5
100-139
0.5
0.5
0.5
1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes
Fluid Temp.
Piping System Types
Range("F)
Heating Systems
Low PressurefTemperature
201-250
Low Temperature
106-200
Steam Condensate (for feed water)
Any
Cooling Systems
Chilled Water, Refrigerant and
40-55
Brine
Below 40
NOTES TO FIELD: (Building Department Use Only)
HORSEHAVEN LOT 3, BILK 1, PH2
Insulation Thickness In Inches by Pipe Sizes
2" Runouts
1" and Less
1.25" to 2.0"
2.5" to 4"
1.0
1.5
1.5
2.0
0.5
1.0
1.0
1.5
1.0
1.0
1.5
2.0
0.5
0.5
0.75
1.0
1.0
1.0
1.5
1.5
Page 5 of 5