HomeMy WebLinkAboutRES2006-03441, 06-3442M,
01/10/2007 11:23 FA% 9796902504
i
i
i
I
CERTIFIED COPY
Q 002
N5'„ t -
25�3a
2
HOUSE WAS SET BACK AN ADDMONAL 6'
I' GCecJ �� TO PRESERVE TREES liPAi/06)
_Do
M
to
1
3
I �
0
� M
Z
2703 HORSEHAVEN LANE
LOT: 2
BLOCK: 1
4 SECTION: 2
IN 3
F68 HORSEHAVEN ESTATES
0 5' -at ` _ COLLEGE STATION, TEXAS
� i .
i c\l
22�97" 9- co
l/
20'_ _ SITE PLAN
2703 14'• 16'_4.. SCALE: 1"=20'
H�RSfHAVElV R4304.89'
CAtve BUILDER:
OAKWOOD CUSTOM HOMES GROUP LTD.
1/10/2007 11:23 FAX 9796902504 CERTIFIED
2703 MORHAVEN LANOEKWOOD CUSTOM
SE
COPY
HOMEBUILDERS LLC. Cd e"5b� 6� 7845
(979)-690-2504
%.vaivm nvmcauiLU 5 LLC. HOME PLAN DESIGN SERVICE
PREPARED 6/27/07, 7:35:28 INSPECTION TICKET PAGE 1
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 6/26/07
------------------------------------------------------------------------------------------------
ADDRESS . : 2703 HORSE HAVEN LN SUBDIV:
CONTRACTOR OAKWOOD CUSTOM HOMES PHONE (979) 690-1504
OWNER . . PHONE
PARCEL . . 336300-0201-0020
APPL NUMBER: 06-00003441 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERPIIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 1/03/07 BI BLDG, FOUNDATION -SLAB TIME: 17:00
1/03/07 CA
B100 03 1/05/07 RH BLDG, FOUNDATION -SLAB TIME: 17:00
1/05/07 AP January 5, 2007 10:40:42 AM ncochran.
late, late afternoon
O1/05/2007 03:59 PM RH PDA
Strings up, slab ground installed.
^`B100� 02
1/05/07
RH
BLDG, FOUNDATION -SLAB TIME: 17:00
1/05/07
CA
January 4, 2007 10:20:28 AM kwolfe.
January 5, 2007 10:40:06 AM ncochran.
contractor called to cancel
15 01
2/01/07
DS
BLDG, FRAMING TIME: 17:00
2/02/07
AP
February 1, 2007 1:50:58 PM ncochran.
B130 01
2/07/07
OC
BLDG, INSULATION TIME: 17:00
2/07/07
AP
February 6, 2007 4:44:19 PM glsouth.
B125 01
/�i6`/07
BLDG, FINAL TIME: 17:00
)vAm
une 26, 2007 3:34:52 PM kwolfe.
------------
0-?--------
-----
a
----- CONTINUED ONTO NEXT PAGE ----------------------------
In
0
PO
0
Date: 6/27/2007
Inspection Comments for Finals
Permit Year: 6 Permit Number: 3441
Address: 2703 HORSE HAVEN LN
Insp.
inspection Type Code
p.
status
Inspection Result Comments
Description
B100
BLDG, FOUNDATION -SLAB
IC
January 5, 2007 10:40:06 AM ncochran.
B100
BLDG, FOUNDATION -SLAB
IC
contractor called to cancel
B100
BLDG, FOUNDATION -SLAB
IC
01/05/2007 03:59 PM RH PDA
B100
BLDG, FOUNDATION -SLAB
IC .
Strings up, slab ground installed.
P100
PLBG, ROUGH IN
IC
December 8, 2006 4:49:16 PM ncochran.
P105
PLBG, TOP OUT
IC
01/22/2007 04:34 PM JGM PDA
P105
PLBG, TOP OUT
IC
No water on system. Need vacuum breakers on hose bibs.
Page 1
WF0850626 /
001 City of College' Sta,ion
PAGE 1
REQ. DATE:
11/17/06
11/17/06
16:23:58
LOCATION:
2703 HORSE HAVEN LN
LOC ID:
205412
REQUESTOR:
OAKWOOD CUSTOM HOMES ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER: KWOLFE
WORK TYPE:
ROUT
TEMP POLE
PASSED
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT SET
READY
SCHED START:
11/17/06 SCHED COMPLETION:
11/17/06
********************************************************************************
JOB ORDER RESULT
COMMENTS -1_ I I
66,-3
WF0850538 / 002 City of College Station
PAGE 1
REQ. DATE:
11/17/06
11/17/06
13:23:52
LOCATION:
2703 HORSE HAVEN LN
LOC ID:
205412
REQUESTOR:
OAKWOOD CUSTOM HOMES ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER: KWOLFE
WORK TYPE:
ROUT
4" SWR
TAP 3/4" WTR TAP
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT SET
READY
SCHED START: 11/17/06 SCHED COMPLETION:
11/17/06
********************************************************************************
JOB ORDER
RESULT COMMENTS
BUILDING PERMIT
CITY 04.ZQ;TrLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979) 764-357;0 FAX: (979) 764-3496
----------------------------------------------------------------------------
Application Number . . . . . 06-00003441 Date 11/16/06
Property Address . . . . . . 2703 HORSE HAVEN LN
Property ID: 336300-0201-0020
R #:
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . HORSE HAVEN PH 2
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation 95000
Owner
Contractor
------------------------
------------------------
OAKWOOD CUSTOM HOMES
4060 SH 6 S
COLLEGE STATION
TX 77845
(979) 690-1504
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
1282.00
INTERIOR WALL TYPE
2X4
NUMBER OF BATHROOMS
2.00
NUMBER OF BEDROOMS
3.00
SEWER TYPE
PUBLIC
TAZ
225.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
KW
Permit Fee . . . .
440.00 Plan Check Fee
.00
Issue Date . . . .
11/16/06 Valuation
95000
Expiration Date . .
5/15/07
Qty Unit Charge
Per
Extension
BASE FEE
260.00
45.00 4.0000
THOU BLDG, VAL 50001-100000
180.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS
THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL
BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS
OPENING (MINIMUM ROUGH -FRAMED SIZE
2211
---------------------
------ ---- --�--
- ----------
----------------------
BUILDING DEPT-EP,
ATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 06-00003441
Page 2
Date 11/16/06
Special Notes and Comments
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
.annular space at ends with caulk, foam or other means.
------------------------ --------------------- ------ --- ----- -_---------
BUILDING DEPT PRES ATIVE:
IV -
APPLICANT:
BUILDING PERMIT
CITY Od COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 3
Application Number . . . . . 06-00003441 Date 11/16/06
----------------------------------------------------------------------------
Special Notes and Comments
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
------------------------------------------- --- -- -- ---- -------------
BUILDING DE PT EPR TATIVE:
APPLICANT:
BUILDING PERMIT
CITY GF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page
4
Application Number . . . . . 06-00003441 Date
11/16/06
----------------------------------------------------------------------------
Special Notes and Comments
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES
Narrow Wall Bracing Fully Sheathed with APA Framing on
Right side of Garage if less than 24"
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
------------------------------
----------------------------
Permit Fee Total 440.00 440.00 .00
.00
Plan Check Total .00 .00 .00
.00
Other Fee Total 750.00 750.00 .00
.00
Grand Total 1190.00 1190.00 .00
.00
---------------------------------------------- ----- --- - --------
BUILDING DEPT EPRE TATIVE:
APPLICANT.
TEMPORARY POLE PERMIT
CITY GF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 FAX: (979) 764-3496
----------------------------------------------------------------------------
Application Number . . . . . 06-00003442 Date 11/16/06
Property Address . . . . . . 2703 HORSE HAVEN LN
Property ID: 336300-0201-0020
R #•
Application type description TEMP POLE
Subdivision Name . . . . . . HORSE HAVEN PH 2
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 0
Owner Contractor
------------------------ ------------------------
OAKWOOD CUSTOM HOMES
4060 SH 6 S
COLLEGE STATION TX 77845
(979) 690-1504
----------------------------------------------------------------------------
Permit . . . . . . TEMP POLE PERMIT
Additional desc . . KW
Permit Fee . . . . 20.00
Issue Date . . . . 11/16/06 Valuation . . . . 0
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
---------------------------------------------------------
Permit Fee Total 20.00 20.00 .00 .00
Grand Total 20.00 20.00 .00 .00
---------------------- ------------------------ ------ ----- -'------
BUILDING DEPT EPR TATIVE: Jd.
n
APPLICANT:
A D
'APPLICATION FOR BUILDING PERMIT
�. CITY OF COLLEGE STATION
t*
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
CITY OF COLLEGE STATION (979) 7643570 (979) 7643496 FAX
Planning & Development Snvica
tNW W.CSTX.GOV
ADDRESS/LOCATION: 2703 HORSE HAVEN LANE
LOT _2 ✓ BLOCK 1 ✓SUBDIVISION _HORSE HAVEN
SEC/PH 2
BUSINESS/OWNER NAME: ALTON OFCZARZAK
DATE: I l It3 J �RCC REG
APPLICATION # r�v�lq$ "/�J�I�j�)'��
TEMP POLE # " `� _ J "l `I
PHONE 979-690-1504
CONTRACTOR/HOMEOWNER: OAKWOOD CUSTOM HOMEBUILDERS PHONE:979-690-1504
CONTRACTOR ADDRESS: 4060 HIGHWAY 6 SOUTH COLLEGE STATION, TEXAS 77845
ELECTRICIAN: CAMPISE ELECTRIC PLUMBER: AGGILAND PLUMBING
HVAC: THREE RIVERS GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION * SLAB ONLY
DUPLEX (Landscape Plans REMODEURENOVATION* SWIMMING POOL
Required)
DESCRIPTION OF WORK: NEW CONSTRUCTION
STRUCTURE USE: SINGLE FAMILY RESIDENTIAL
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD S) PROJECT REGISTRATION# EABPRJ
VALUATION: $ CI S�. 4aU TOTAL AREA:ei?AFrf&'� HEATED AREA:AW C ZO Z
(Cost of Labor and Materials)
PUBLIC SEWER
SEPTIC/TREATMENT SYSTEM
[X SEWER TAP:
15,
M
WATER TAP:
❑ OTHER TAP:
1 p� �X TEMP POLE
v / GARAGE TYPE
4"
SIZE
SIZE
SIZE
SINGLE Q
ATTACHED FX
NUMBER OF BEDROOMS: # ;
NUMBER OF BATHROOMS: A Z
INTERIOR WALL TYPE: 2X4 @ 16
EXTERIOR WALL TYPE: 2X4 c@ 16 W/ BRICK &
HARDI
FOUNDATION TYPE: SLAB & BEAM
ROOF TYPE:
DOUBLE 7X
DETACHED a
TRIPLE Q
CARPORT a
25 YR COMP.
\� SIGNATURE OF APPLICANT:
*If proposed work involves new commercial construction or facade improvements/renovations to an existing
commercial property, building elevations are required.
Official Use Only MOO'NO
nts:
/ '6
IV
Plans Examiner
Zoning Official
Energy Code Compliance Information
% Glazing of exterior walls
11 %
Insulation R value of exterior walls
R 13
Insulation R value of ceiling 1 (flat areas)
R30�
Insulation R value of ceiling 2 (vaulted areas/no attic)
R19
Glazing SHGC
.30
54�
Glazing U-Factor
R value of ductwork
R6
A/C SEER Rating
14_�
•f
Permit #
Permit Date
CREScheck Software Version 3.7.3
\fj Compliance Certificate
Project Title: HORSEHAVEN LOT 2, BLK 1, PH2
Report Date: 11/09/06
Data filename: G:\OAK_DWG\HORSE HAVEN\HH2-2703HHL-wrangler\hh2-2703-horsehavenlane.rck
Energy Code: 2003 IECC
Location: College Station, Texas
Construction Type: Single Family
Glazing Area Percentage: 11%
Heating Degree Days: 1788
Construction Site:
2703 HORSEHAVEN LANE
College Sataion, TX 77845
Owner/Agent:
ALTON OFCZARZAK
OAKWOOD CUSTOM HOMES GROUP
LTD.
4060 HWY. 6 SOUTH
COLLEGE STATION, TX 77845
979-690-1504
PLANS@OAKCHB.COM
Designer/Contractor:
David Park
OAKWOOD CUSTOM HOMES GROUP
LTD. HOME PLAN DESIGN SERVICE
4060 Highway 6 South
College Station, TX 77845
979-690-1504
plans@oakchb.com
f GompIIancT Passes Maximum UA 58.9 Your Home UA: 4.51 --> 23r% Better Tihan Code (UA7
Maximum SHGC: 0.40 0.30
Ceiling 1: Flat Ceiling or Scissor Truss:
1650 0.0
30.0
51
Wall 1: Wood Frame, 16" o.c.:
1558 13.0
0.0
109
1050 sidelite X2: Metal Frame:Double Pane with Low-E:
10
0.540
5
SHGC: 0.30
2030shX2: Metal Frame:Double Pane with Low-E:
12
0.540
6
SHGC: 0.30
3050SH X10: Metal Frame:Double Pane with Low-E:
150
0.540
81
SHGC: 0.30
3068 FRONT DOOR: Solid:
20
0.140
3
2868 BACK DOOR: Solid:
18
0.140
3
2868 TO GARAGE: Solid:
18
0.140
3
CONC. SLAB: Slab-On-Grade:Unheated: , Insulation Depth: 0.0'
182
0.0
190
Heat Pump 1: Air Source: 7.7 HSPF, 14 SEER
Air Conditioner 1: Electric Central Air. 14 SEER
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2003 IECC requirements in
REScheck Version 3.7.3 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Builder/Designer
Company Name
Project Notes:
LOT 2, BLOCK 1, PHASE 2 HORSEHAVEN ESTATES
2703 ,HORSEHAVEN LANE
Date
HORSEHAVEN LOT 2, BLK 1, PH2 Page 1 of 4
CREScheck Software Version 3.7.3
�J( Inspection Checklist
Date: 11 /09/06
Ceilings:
❑ Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 continuous insulation
Comments:
Above -Grade Walls:
Q Wall"1: Wood Frame, 16" o.c., R-13.0 cavity insulation
Comments:
Windows:
❑ 1050 sidelite X2: Metal Frame:Double Pane with Low-E, U-factor. 0.540
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
❑ 2030shX2: Metal Frame:Double Pane with Low-E, U-factor. 0.540
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
❑ 3050SH X10: Metal Frame:Double Pane with Low-E, U-factor. 0.540
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
Doors:
❑ 3068 FRONT DOOR: Solid, U-factor: 0.140
Comments:
❑ 2868 BACK DOOR: Solid, U-factor: 0.140
Comments:
❑ 2868 TO GARAGE: Solid, U-factor. 0.140
Comments:
Floors:
❑ CONC. SLAB: Slab-On-Grade:Unheated, R-0 (uninsulated)
Comments:
Heating and Cooling Equipment:
❑ Heat Pump 1: Air Source: 7.7 HSPF, 14 SEER or higher
Make and Model Number:
❑ Air Conditioner 1: Electric Central Air. 14 SEER or higher
Make and Model Number:
Solar Heat Gain Coefficient:
❑ The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values must be
determined in accordance with the NFRC test procedure or taken from the default table.
Air Leakage:
❑ Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed.
HORSEHAVEN LOT 2, BLK 1, PH2 Page 2 of 4
❑ Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from
combustible materials. If non -IC rated, the fixture must be installed with a 3" clearance from insulation.
Skylights:
❑ Minimum insulation requirement for skylight shafts equal to or greater than 12 inches is R-13.
Materials Identification:
❑ Materials and equipment must be installed in accordance with the manufacturer's installation instructions.
❑ Materials and equipment must be identified so that compliance can be determined.
❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided.
❑ Insulation R-values, glazing U-factors, and cooling equipment efficiency must be clearly marked on the building plans or
specifications.
Duct Insulation:
❑ Supply ducts in unconditioned attics or outside the building must be insulated to R-8.
❑ Return ducts in unconditioned attics or outside the building must be Insulated to R-4.
❑ Supply ducts in unconditioned spaces must be insulated to R-6.
❑ Return ducts in unconditioned spaces (except basements) must be insulated to R-2.
❑ Where exterior walls are used as plenums, the wall must be insulated to R-8.
❑ Insulation is not required on return ducts in basements.
Duct Construction:
❑ Dud connections to flanges of air distribution system equipment must be sealed and mechanically fastened.
❑ All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives),
mastio-plus-embedded-fabric, or tapes. Tapes and mastics must be rated UL 181A or UL 181B.
Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500
Pa).
❑ The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
❑ Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the
heating and/or cooling input to each zone or floor shall be provided.
Service Water Heating:
❑ Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral
heat trap or is part of a circulating system.
❑ Insulate circulating hot water pipes to the levels In Table 1.
Circulating Hot Water Systems:
❑ Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
❑ All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from
non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
❑ HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F must be insulated to the levels in Table
2.
HORSEHAVEN LOT 2, BLK 1, PH2 Page 3 of 4
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes
Insulation Thickness In Inches by Pipe Sizes
Non-Clrculadng Runouts
Circulating Mains and Runouts
Heated Water
Temperature ("F)
Up to 1"
Up to 1.25"
1.5" to 2.0"
Over 2"
170-180
0.5
1.0
1.5
2.0
140-169
0.5
0.5
1.0
1.5
100-139
0.5
0.5
0.5
1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes
Fluid Temp.
Piping System Types
Range("F)
Heating Systems
Low Pressure/Temperature
201-250
Low Temperature .
106-200
Steam Condensate (for feed water)
Any
Cooling Systems
Chilled Water, Refrigerant and
40-55
Brine
Below 40
NOTES TO FIELD: (Building Department Use Only)
HORSEHAVEN LOT 2, BLK 1, PH2
Insulation Thickness In Inches by Pipe Sizes
2" Runouts
1" and Less
125" to 2.0"
2.5" to 4"
1.0
1.5
1.5
2.0
0.5
1.0
1.0
1.5
1.0
1.0
1.5
2.0
0.5
0.5
0.75
1.0
1.0
1.0
1.5
1.5
Page 4 of 4
r
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# DATE:
BUILDING ADDRESS:
a 70 3 Moase 14xqvenl LAI -
I. Foundation Requirements
N
A. Concrete minimum fc of 3000 PSI
B. Minimum four 4 inch slab thickness
C. Vapor barrier 6 mil. Poly min.
D. Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior unless over 60' Ion
3. Spacing of beams does not exceed 15'
E. Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F. Wood foundation details indicated
OK
Il. Framing: Floor, Wall, Ceiling and Roof Requirements
NA/QV
A. Girder or sill dimensions, grade & species
B. Floor joist size, spacing, grade & direction of span indicted on plans
C. Treated sill plate or bottom plate
D. Tenant separation in duplex
K
1. One -hour rated extending to roof deck
K
E. Header sizes indicated on plans
F. Emergency bedroom egress
1. Exit direct to outside
2. O enable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G. O enable bathroom window required when mechanical ventilation is not rovided
H. Stud grade andspacing
I. Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J. Roof framing plan or elevation shown
K. Ceiling joist size, spacing, rade and direction of span indicated on plans
L. Attic access location and size indicated on plans
M. Span exceeding code tables must be engineered
N. Rafter size and spacing and purlin bracing indicated.
O. Roof covering used.
P. Indicate Wall Bracing Used for Lateral Bracing
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
II. Framing: Floor, Wall, Ceiling and Roof Requirements continued
N
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
S. 18" Overhang allowed on zero lot line construction, perforated soffit allowed.
T. Protected openings on walls < three feet from property line
OK
III. Stairway Requirements
OK
A. Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" diff. max.
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches above handrail
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located four or more risers above floor/ rade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four (4) inch sphere
IV. Fireplace Requirements to be indicated onplans)
OK
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must extend at least three (3) feet higher than the highest point where it
projects through the roof of a building & at least two (2) feet higher than any portion of the
building within ten (10) feet horizontal
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
V. Electrical Service Requirements
N
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
VI. Plumbing Requirements
N O
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
NAJW
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units)
7
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
O
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N
Maximum drive width for residence is 25' combined for circular 12' minimum
Minimum 20 feet from driveway to side(intersecting) street
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
N K
Does not block any water course or divert any flow
Elevation certifigate needed
OK
PLANS EXAMINER DATE