PREPARED 5/31/07, 12:01:02
INSPECTION TICKET PAGE 4
City of
------------------------------------------------------------------------------------------------
College Station
INSPECTOR: BUILDING INSPECTOR DATE 5/31/07
ADDRESS
. : 1506 HUNTER CREEK DR - SUBDIV: SHENANDOAH PH 19
CONTRACTOR ED FROEHLING BUILDERS PHONE (979) 776-8266
OWNER
ED FROEHLING BUILDER INC PHONE
PARCEL
569500-1948-0090
APPL NUMBER: 06-00003417 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT:
BLDG 00 BUILDING PERMIT
REQUESTED INSP
DESCRIPTION
TYP/SQ
COMPLETED RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01
1/04/07 RH
BLDG, FOUNDATION -SLAB TIME: 17:00
1/04/07 AP
January 4, 2007 11:12:43 AM kwolfe.
Strings On Setbacks O.K.
Slab Ground Installed
B115 01
2/08/07 RH
BLDG, FRAMING TIME: 17:00
2/08/07 AE
February 8, 2007 7:56:57 AM kwolfe.
�;.
02/08/2007 10:50 AM RH PDA
-
Add purlin brace above hallway and brace under hip in
front bedroom.
B130a01
2/15/07 RH
BLDG, INSULATION TIME: 17:00
2/15/07 DA
February 15, 2007 11:42:00 AM glsouth.
02/15/2007 04:11 PM RH PDA
Need to complete purlin brace for last 4 rafters above 1st
bedroom doorway.
B130 02
2/20/07 ,OC
BLDG, INSULATION TIME: 17:00
2/20/07 AP
February 20, 2007 10:47:46 AM ncochran.
B125 01-
5/31/07 I�
BLDG, FINAL TIME: 17:00
31O Y'� CC.
May 31, .2007 8:40:53 AM acarter.
-------------------------------------- COMMENTS AND NOTES--------------------------------------
g
NO
Date: 5/31/2007
Inspection Comments for Finals
Permit Year: 6 Permit Number: 3417
Address: 1506 HUNTER CREEK DR
Insp.
Inspection Type code
Description
p.
Status
Inspection Result Comments
B100
BLDG, FOUNDATION -SLAB
IC
Strings On Setbacks O.K.
B100
BLDG, FOUNDATION -SLAB
IC
Slab Ground Installed
B115
BLDG, FRAMING
IC
02/08/2007 10:50 AM RH PDA
B115
BLDG, FRAMING
IC
Add purlin brace above hallway and brace under hip in
B115
BLDG, FRAMING
IC
front bedroom.
B130
BLDG, INSULATION
IC
02/15/2007 04:11 PM RH PDA
B130
BLDG, INSULATION
IC
Need to complete purlin brace for last 4 rafters above 1st
B130
BLDG, INSULATION
IC
bedroom doorway.
M100
MECH, ROUGH IN
IC
02/07/2007 02:47 PM RH PDA
M100
MECH, ROUGH IN
IC
Furnace flue pipe needs a min. 1" of clearance from roof
M100
MECH, ROUGH IN
IC
decking by final.
Page 1
WF0864082 / 001 City of College Station
PAGE
REQ. DATE:
01/08/07
01/08/07
10:22:10
LOCATION:
1506 HUNTER CREEK DR
LOC ID:
204784
REQUESTOR:
ED FROEHLING BUILDERS ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER: KWOLFE
WORK TYPE:
ROUT
TEMP POLE
PASSED
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT SET
READY
SCHED START:
01/08/07 SCHED COMPLETION:
01/08/07
********************************************************************************
JOB ORDER RESULT COMMENTS
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION a),344-1
1101 TEXAS 1�.VE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
06-0000363S Date
12/06/06
Property Address . . . . . .
1506 HUNTER CREEK DR
Property ID:
569500-1948-0090
R #:
R304142
Application type description
TEMP POLE
Subdivision Name . . . . . .
.SHENANDOAH PH 19
Property Use . . . . . . . .
RESIDENTIAL
Property Zoning . . . . . . .
SINGLE FAMILY RESIDENTIAL
Application valuation . . . .
0
Owner
Contractor
------------------------
ED FROEHLING BUILDER INC
------------------------
ED FROEHLING BUILDERS
3887 HIGH LONESOME
3887 HIGH LONESOME RD
COLLEGE STATION TX 778459443
COLLEGE STATION
TX 77845
(979) 776-8266
----------------------------------------------------------------------------
Permit . . . . . . TEMP POLE
PERMIT
Additional desc . . GS
Permit Fee . . . . 20.00
Issue Date . . . . 12/06/06
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . . . . . . . . .TEMP
ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary Charged
Paid Credited
------------------------------
Due
---------------------------
Permit Fee Total 20.00
20.00 .00
.00
Other Fee Total 45.00
45.00 .00
.00
Grand Total 65.00
65.00 .00
.00
,y `- - -----------
BUILDING DEP-T--REP ESENTATIFE_
APPLICANT:
WFO850054 /
001 City of College Station
PAGE 1
REQ. DATE:
11/16/06
11/16/06
8:38:03
LOCATION:
1506 HUNTER CREEK DR
LOC ID:
204784
REQUESTOR:
ED FROEHLING BUILDERS ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
NCOCHRAN AUTH. USER: NCOCHRAN
WORK TYPE:
ROUT
4" SWR TAP 3/4" WTR TAP
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT SET
READY
SCHED START:
11/16/06 SCHED COMPLETION:
11/16/06
********************************************************************************
JOB ORDER RESULT COMMENTS
Mina Southerland - Re: Calling for C.O. @ 1506 Hunter reek Page 1
From: Joe Garcia
To: Benjamin McCarty; Chris Haver; Gina Southerland; Kim Wolfe; Mitchell...
Date: 6/1/2007 1:08 PM
Subject: Re: Calling for C.O. @ 1506 Hunter Creek
THIS ONE IS OK. JMG
>>> Gina Southerland 05/31/07 11:30 AM >>>
BP# 06-3417
Gina Southerland
CSR - Planning & Development Services
City of College Station
979-764-3570
www.cstx.gov
BUILDING.PERMIT
CITY OF C 2LL_ EGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 -FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 06-'00003417 Date 11/15/06
Property Address . . . . . . 1506 HUNTER CREEK DR
Property ID: 569500-1948-0090
R #: R304142
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . SHENANDOAH PH 19
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 148434
Owner Contractor
------------------------ ------------------------
ED FROEHLING BUILDER INC ED FROEHLING BUILDERS
3887 HIGH LONESOME 3887 HIGH LONESOME RD
COLLEGE STATION TX 778459443 COLLEGE STATION TX 77845
(979) 776-8266
--- Structure Information 000 000 SINGLE FAMILY
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info . . . . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID PAID
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT-
HEATED AREA 2249.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 2.00
NUMBER OF BEDROOMS 4.00
SEWER TYPE PUBLIC
TAZ 427.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . . NC
Permit Fee . . . . 607.00 Plan Check Fee .00
Issue Date . . . . 11/15/06 Valuation 148434
Expiration Date . . 5/14/07
Qty Unit Charge Per Extension
BASE FEE 460.00
49.00 3.0000 THOU BLDG, VAL 100001-500000 147.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTERS)
PROVIDE ATTIC ACCESS OPENING (MINIMUM OUCH -FRAMED SIZE 2"
--------------------- -----
------------
---- ---- - - ----------------
BUILDING PT REPRE ENTATIVE:_
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 06-00003417
Page 2
Date 11/15/06
Special Notes and Comments
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
BUILD
APPLI
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 3
Application Number . . . . . 06-00003417 Date 11/15/06
----------------------------------------------------------------------------
Special Notes and Comments
ANY CHANGES OR ALTERATIONS.TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
BUILD
APPLI
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page
4
Application Number . . . . . 06-00003417 Date
11/15/06
----------------------------------------------------------------------------
Special Notes and Comments
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES
Narrow Wall Bracing Fully Sheathed with APA Garage Framing
and Interior Anchors and bracing at front door area.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
------------------------------
---------------------------
Permit Fee Total 607.00 607.00 .00
.00
Plan Check Total .00 .00 .00
.00
Other Fee Total 750.00 750.00 .00
.00
Grand Total 1357.00 1357.00 .00
.00
-------------
BUILD
APPLI
APPLICATION FOR BUILDING PERMIT
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
CITY OF COLLEGE STATION CSTX.GOV
Pktnning d Dmdopment SemiceJ
ADDRESS/LOCATION: l�
LOT BLOCK —4:5—`' SUBDIVISION
BUSINESS/OWNER NAME:
CONTRACTOR/HOMEOWNER: C-6J
CONTRACTOR ADDRESS:
For Office Use Onty
DATE: 11�9
,�f§ TRCCR(E�G
APPLICATION # 02
� - J I (�
TEMP POLE #
PHONE:
SEC/PH✓
ELECTRICIAN: ` PLUMBER:
HVAC: GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION Mel G SHELL ONLY
DEMOLITION (Asbestos Survey) CONSTRUCTION " SLAB ONLY
DUPLEX (Landscape Plans) REMODEL/RENOVATION* SWIMMING POOL
TENT/CANOPY
DESCRIPTION OF WORK:
PROPOSED USE:
HOMEOWNER ASSOCIATION/ARCHITECC.TUAL OR DESIGN RE -COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRA ION# EABPRJ
VALU TION: $ , 4� - 00 TOTAL AREA: 9041 HEATED AREA: 2Z 4
(Cost of Labor aInd Materials)
PUBLIC SEWER
S SEWER TAP: ` TIC/TREATMENT SYSTEM
it
[2/WATER TAP: &S E `'
SIZE
OTHER TAP:
SIZE
❑ TEMP POLE
GARAGE TYPE: SINGLE F1
ATT
SIGNATURE OF APPLICANT.
*If proposed work involves new c mm
commercial property, building elevatio
NUMBER OF BEDROOMS
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
)OUBLE �RIPLE
ETACHED JI—L. CARPORT
construclwon or tacaae
Offi 'al Use Only
_0�
Plans Examiner
Zoning Official
� ��A""Q o,,�e InII H 3a ents:
� " t-v I ��t.�J' /g7�R kESfJr NO
t—
tc c �
ins to an existing
Fire Marshall
W
�;� ARC
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1. (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor
R value of ductwork
A/C SEER Rating
R 94
(�4% V
11COLkE7ESTATIONL
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# DATE:
06-
BUILDING ADDRESS:
I. Foundation Requirements
N
A. Concrete minimum f c of 3000 PSI
B. Minimum four 4 inch slab thickness
C. Vapor barrier 6 mil. Poly min.
D. Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior unless over 60' Ion
3. Spacing of beams does not exceed 15'
E. Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F. Wood foundation details indicated
tflA10K
II. Framing: Floor, Wall, Ceiling and Roof Requirements
A/
A. Girder or sill dimensions, grade & species
B. Floor joist size, spacing, grade & direction of span indicted on plans
C. Treated sill plate or bottom plate
D. Tenant separation in duplex
I(
1. One -hour rated extending to roof deck
K
E. Header sizes indicated on plans
F. Emergency bedroom egress
1. Exit direct to outside
2. O enable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G. O enable bathroom window required when mechanical ventilation is not provided
H. Stud grade andspacing
I. Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J. Roof framing Ian or elevation shown
K. Ceiling joist size, spacing, rade and direction of span indicated on plans
L. Attic access location and size indicated on plans
M. Span exceeding code tables must be engineered
N. Rafter size and spacing and purlin bracing indicated.
O. Roof covering used.
P. Indicate Wall Bracing Used for Lateral Bracing
r
i
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
II. Framing: Floor, Wall, Ceiling and Roof Requirements continued
N
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
S. 18" Overhang allowed on zero lot line construction, perforated soffit allowed.
T. Protected openings on walls < three feet from property line
K
t_
III. Stairway Requirements
OK
A. Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" diff. max.
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches above handrail
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located four or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four (4) inch sphere
IV. Fireplace Requirements to be indicated onplans)
N
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must extend at least three (3) feet higher than the highest point where it
projects through the roof of a building & at least two (2) feet higher than any portion of the
building within ten (10) feet horizontal
4
I
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
V. Electrical Service Requirements
N
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
VI. Plumbing Requirements
N
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
NA/
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units)
7
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
N O
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
NAtOA
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
NA/
Maximum drive width for residence is 25' combined for circular 12' minimum
Minimum 20 feet from driveway to side(intersecting) street
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
NA/
Does not block any water course or divert any flow
Elevation pertificate needed
K
PLANS EXAMINER DATE
Bunter Creek
50' R.O.W. - 27' Pavement
Scale 1 " = 20'
N 45 02' 18" E - 65.0'
i
REScheck Compliance Certificate
2000 IECC
RES check Software Version 3.5 Release I
Data filename: C:\Program Files\Check\REScheck\1200HB.rck
TITLE: 1506 Hunter Creek
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 11 /02/06
DATE OF PLANS: 2/7/06
PROJECT INFORMATION:
SHENANDOAH PHASE 14
LOT 9 BLOCK 48
COMPANY INFORMATION:
Ed Froehling Builder, Inc
NOTES:
SAME AS 1417 DY
COMPLIANCE: Passes
Maximum UA = 757
Your Home UA = 617
18.5% Better Than Code (UA)
Maximum SHGC = 0.40
Your SHGC = 0.35
Ceiling 1: Flat Ceiling or Scissor Truss
Wall 1: Wood Frame, 16" o.c.
Window 1: Metal Frame:Double Pane with Low-E
SHGC: 0.40
Bldg. faces 315 deg. from North; Comp. orient.: Front
Projection factor: 0.19
Door 1: Solid
Wall 2: Wood Frame, 16" o.c.
Window 2: Metal Frame:Double Pane with Low-E
SHGC: 0.40
Bldg. faces 315 deg. from North; Comp. orient.: Left Side
Projection factor: 0.23
Wall 3: Wood Frame, 16" o.c.
Window 3: Metal Frame:Double Pane with Low-E
Permit Number
Checked By/Date
Gross
Glazing
Area or
Cavity
Cont.
or Door
Perimeter
R-Value
R-Value
U-Factor UA
2249
30.0
0.0
79
423
13.0
0.0
26
63
0.640 40
38
484 13.0 0.0
32
0.400 15
37
0.640 21
397 13.0 0.0 22
109 0.640 70
SHGC: 0.40
Bldg. faces 315 deg. from North; Comp. orient.: Back
Projection factor: 0.23
Door 2: Glass
SHGC: 0.78
Bldg. faces 315 deg. from North; Comp. orient.: Back
Projection factor: 1.02
Wall 4: Wood Frame, 16" o.c.
Window 4: Metal Frame: Double Pane with Low-E
18
495 13.0 0.0
45
SHGC: 0.40
Bldg. faces 315 deg. from North; Comp. orient.: Right Side
Projection factor: 0.23
Floor 1: Slab-On-Grade:Unheated 222
Insulation depth: 0.0'
Air Conditioner 1: Electric Central Air, 13 SEER
0.0
0.580 10
37
0.640 29
231
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications,
and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC
requirements in REScheckVersion 3.5 Release lb (formerly MECchec� and to comply with the mandatory requirements listed in
the RES check I nspection_Cheeki ist. a
Builder/Design
Date f ([ 2GI