HomeMy WebLinkAboutSP2010-500101 (3)t-
TOPNUT OF EXISTING FIRE HYDRANT ON
IAN DRIVE APPROX. 440' EAST OF LASSIE LN.
)210844.55, Elev= 294.43
\� Exist. 8"
\ Waterline
257' Opposite Left
(To Lassie Lane)
Q
PB
e-wr- rs-wL ---- o-wL a-wL
BENCHMARK: ~°
237' Opposite Right TOP NUT FIRF HYDRANT
'm
(To Next Drive) ELEV. = 2941.43' O
Exist.�o 0 Conduit99�~HOLLEM4__) DRIVE EA_§ �fl
�, C
CAUTION!
CONTRACTOR SHALL FIELD VERIFY Prop. 2" Gas Line -Cap End
DEPTH OF EXISTING FIBER OPTIC LINE Prop. 2-2" Repair Sidewalk for Future Connection to
ATMOS Gas Line
170' Adjacent Left
(To Next Drive)
298 Exist. Underground Exist. Poly
Tele hone_ .. _,._ Gqs. Line
299 P ;
- --
c:,-___ �..-�-... - - UT UT-^^-�--UT UT UT t
R25.5'
� e-WL � � � 8-WL � �8-.._� � � �!-rYL� � � � E-WL- � - 8 WL� � � g-yyL��
-GAS:. .., - 4-GAS - __.4-GAS - 4-GAS �3 -f ,..,...�_..., 4-_GAS. r-- 4 -GAS -.-. - 4-GAS .__-._ _.-_ 4 >A> ---�r�
IV __, 41
190.48
_ \ Prop. 8" PVC `� O
Waterline ..
30,5 �� Ii 26'
0`
_._. __ _ Dumpster Pad
I' Dumpster Enclosure
r
kIJ
z
B-WL \ tl-WL
Rose -Arbors LP
A004601 M Rector (ICL), Tract 97,
"Arbors at Wolf Pen Apts" Exist. Fire
Vol. XX, PG. XX Hydrant m Exist. Pull
Current Zoning: WPC -- - - i - BOX _- - -
a-WL
q� ?9� �� � 1 9
PVC Conduit Area 5.
328' Adjacent Right 111%
(To Next Drive) `� . Prop. Pull
--- - - - __ Box
\ °a
Prop. 6' Sidewalk 7'
2-2"-PVC-EC - 2-2"-PVC-EC - - - 2-2"-PVC-EC
Exist. 4' Sidewalk
Handrails -See 294 Prop. Sanitary
„'---_-._Arch__Plan� for _ Sewer MH c_ 2-2'r� fie- .uL =- z-�.._wc-Ec -
ry _ __. __._-_- __.-_----4 I Pc T���' - 2-2'•-PVc- .- - 2-2" c-EC
Detail _`_ur------------
R25.5 / r> > s-SS--- __SS G_ss 6_S5 \
20' P.U.E. N 41 *31 31 E 25v.vv --- - - __ -
GAS - - - 4...GAS ----- --- 4-G,ti ---- -`- 4-GAS --- --_-- 4-GAS r_ --GAS --- ----- 4--CAS 4_GAS -t=A=� a_.GA
S .._._--- 4--GAS ._-_.-'-----' .>F.S __. - .__.._- 4-GAS --- - - 4--GAS - _. AS
Handrails -See Arch. " %y
n - 7-- Plans for Detail Prop. Public 6" e �{
I LA
X PVC Sanitary
v �,• Sewer �'
290
0
O O
c7 9
e
41.
/
O '
.J
-XX Wooden Fence
i
^„5..;
-
C.
i�
Verizon Parking Lot
308
FIRE LANE
Verizon Communications Inc.
Poch's Park, Lot 1 R, Block 2
Vol. 8808, PG. 25
Current Zoning: C-1
All curbs and curb ends designated as
firelanes on plans shall be painted red
with 4" (four inch) white lettering stating
"FIRE LANE -NO PARKING -TOW AWAY ZONE"
Wording may not be spaced for than
fifteen (15) feet apart. In addition to the
curbs being striped, a fire lane sign 12" wide
r
4 FF= 00.50 _ -.._..
w
R2.5 Exist. Detention Pond
R4.5' � ��� -' 4'x4'
r Prop. 6 Sidewalk
Dumpster Pad
R2.5' R25.5' a I - --
8' 8' g' g' Prop. 6" PVC
Exist. 25' oint I R20.5' p' ao Sanitary Sewer
Access Easement e-SS- 6-SS ss-- 6-ss Prop. 12"
Vol 8808, PG. 25 1 7 I ( HDPE
Ci l_rl II ��i I
-- ---� r--- :-----_--_--�-_ --=_-.R_2.5'
C riRF. 1AN-FIRE LANE Pr1 NE FIRE ANE RF_NE FIRE LANE FIRE _ANE�F:I.E LANE _IRC LANE FIRE LANE
t
-tR25.5'
R2.5' R2.5' � 4!t HDPE- ?-HDP42 HDPE2 HDPE-- 42-HDPE
N-r----`- Exist. Retaining Wall
L- -J- 2 DP ` 42 -HDPE-y - - 42 HDPE - HLW� = 4Z _-
l:
Prop. Sidewalk I _... = L F _
& Steps " `. n I I DPE- _12-HDP I-f-� L�^= 42�P'E_�- --`f 4 H[�E - 42 HDP I
..t� R25.5' FDPE 12 - 7 - 42 `HD E-'r 42 HDPE- 4 H E----
rn
'-_--- --=.CIA-L .jiil3 =v 38?3---�.�;.««,_-+;-3�r -:w:;.terra-'-7a�3'-r:'ar3'31G�r'�-?rr�-T""r?'s•T3Ne"'32i1 ,. �, N Existing Terra Title
-lc�`�,. R2.5' Company Building
Prop. 8" 2 141 I Prop. 24"
PVC 42 h
Waterline$ R 5 5 R2.5' HDPE ETYP �I HDPE VICINITY MAP
TS
NAr. GENERAL CONSTRUCTION NOTES:
�o I 1. It shall be the responsibility of the Contractor to verify the exact location of ALL existing
�° N z underground utilities. Furthermore, the Contractor shall contact all utility company
R�•5' �_
m SI representatives a minimum of 48 hours in advance of any excavation.
T N
_A a. Contact Dig Tess ® 1-800-344-8377
0- UC,
I b. Contact Kimberly Winn ® ATMOS 774-2506
I\ TYP 23 N Terra Title Company L C c. Contact Mike Lavender ® Suddenlink 846-2229
�' V L. .
NN, Holleman Place, Lot 1 R, Block 2 d. Contact Gilbert Martinez @ College Station Electrical 764-3660
l N e. Contact Mitchell Gas ® 779-4460
f
Vol. XX, PG. XX f. Contact Union Pacific Resources @ 778-8525
Current Zoning: C-1 g. Contact Richard Wallace ® Verizon 821-4752
\ I r 1 T h. Contact Butch Willis ® College Station Water & Sewer 764-3660
FF 3Q200 e
I�
2. All construction shall be in accordance with the current City of College Station (C.S.)
�D ,.i o I Standard Specifications for Street Construction, B/CS Unified Technical Specifications, Water and
L,, Sewer and Generals, 2007, and BCS Unified Design Details. All inspection shall be performed by
I z �, Exist. 15
.�-,;.�:�"-. ,�3..t;:.t x..�E..:. .,:� .._.. _ �..... ,y.,,, _. ..., N ' P.U.E. the
a� m „_. ,'t _ „..;,i r ,:,,. _ staff of the City Engineer of C.S. All construction shall be coordinated with the City of C.S.
s
Vol. 314, PG. 618 City Engineer.
1 _ Z Prop. 6' Sidewalk N �J (To Be Abandoned) 3. In lieu of using the construction materials indicated in these plans, the Contractor shall
obtain written approval from the City Engineer for any substitution prior to Construction.
�, I �(� Requests for changes should include product information and an engineers seal where
e- Water 9' 8' 8' 8' applicable. The contractor shall be financially responsible for the engineer's time spent
Meter TYP TYP l CD reviewing changes and redesigning based on contractors requests.
o z '
-TYP oo !j �� 4. Trench Safety Requirements shall be in accordance with O.S.H.A. Standard 29 CFR Part
17
\/ " _ �, yI 1926 Subpart P. For general requirements, see Sheet S3 for details.
R25.5' <� C1 1 3 (� Ni 5 TRENCHING AND BACKFILLING• All trenchin and backfillin shall conform to the
Prop. Retaining -
Wall
- - Height LA ��•»*aFIRE t -�_- 'FiR.:, �. .AFIRE LANE LAF;E'Pr'+• FIRE' LANE FIRE L r - •»_��•^'FIR. ::.?.?�:. w«.n,�..;�,,- <;,',:.
Varies 0"-12" E I r; i 20' P.U.E. R2.5'
r Prop. Fire R2.5' r•-
!F Hydrant James P. Miles
Pooh's Park, Lot 2R, Block 2
Prop. 4" PVC C4 Vol. XX, PG. XX
Sanitary Sewer Current Zoning: PDD
and 18' in height (as seen hereon) shall be
I I
R1.5' �Ji� �i�•""".`.
R2.5 M
mounted at each entrance.*
20' P.U.E.
_ 3MIA 3
i
a>.v l aat+ _Nci aal r
+ ; ._� ._ ;N. a,:� 1-4
nJ t
x.� _ a
N
R25.5'
4
* 8" (eight inch) high red stripe and 4"
N - y
`''f
'00 a_
T
TYP
(four inch) white lettering may be
r
striped on the surface of the pavement
behind parking stalls in lieu of signage.
al m
r
, kI
Prop. 6' Sidewalk
-FIRE L4NE ®NO .ARKING IOi4 AWAY
(A
�I
el�s� �*SS'IeR
I e•, :.
*FIRE LN* STRIPING I . ' ,
18x 12" Prop. v A t
I t
T
See Ordinance for 2-2" PVCf I t d
I `
adiional Information ' Conduit 24
N {
ti� 5
FIRE LANE SIGNII
FF 303.75
„ m \
£ PVC WL o li+
R21` Prop, 3' Wide hE
L-1 -- ----- ----- -- -- * - Flume w/ 6" Curb II
Q w Water Meter
WProp. 2" Gas Line -CapI
I - 2-2"-PVC-EC - 2-2"-PVC-EC - - 2-2"-PVC-EC - 2-2"-PVC-EC - 2-2'-PVC-EC
Exist. 15' P.U.E. End for Future Connection
Prop. -TYP Transformer Pad Vol. 314, PG. 618 to an Adjacent Bldg.
- -
Ni A Io_ 2)3 ,) E 205.00'
6„ 2-12'x12' 1N -r I ..�- Fifty Three Properties LTD
ply 3„
Dumpster Pad Richards PH 1
r Lot 18-B, Block 1
6" �'b Fifty Three Properties LTD I Fifty Three Properties LTD I �� Vol. 6331, PG. 125
Richards PH 1 Richards PH 1 Current Zoning: R-1
3' Lot 16-B, Block 1 Fifty Three Properties LTD
f I I I Lot 17-B, Block 1 I II � Vol. 6331, PG. 125 Vol. 6331, PG. 125 Richards PH 1 `-'`<'
c f Current Zoning: R-1 Fifty Three Properties LTD Current Zonin g' R-1 Lot 18-A, Block 1
#4 Bars V I 1 PG 1 \
6„ 4000 PSI Concrete
VA
ARD CONCRETE PAVEMENT DETAIL
NTS
nT .
TYPE 3 CURB
FOR USE WITH CONCRETE PAVEMENT OR APRON
NOT A SEPARATE PAY ITEM
NTS
Richards PH 1 o . 633 25
Lot 17-A, Block 1 I I Current Zoning: R-1
Vol. 6331, PG. 125
Current Zoning: R-1
Prop. 18"
HDPE
I Scale: II
r 1 inch - 20 feet 1
LEGEND
FIRE DEPARTMENT CONNECTION
®
WATER METER
o-
WATER VALVE
Q.
FIRE HYDRANT
SANITARY SEWER CLEANOUT
SANITARY SEWER MANHOLE
STORM DRAIN CURB INLET
RAMP WITH ADA PAVERS
0
TRANSFORMER PAD
Pa
ELECTRICAL PULL BOX
sG
ELECTRICAL SWITCH GEAR
9 9
specifications set out herein. Testing shall be provided by a certified laboratory, at the Owner's
expense, to verify these standards. Any retesting due to substandard work shall be at the
expense of the Contractor. Structural areas shall include all sidewalks and shall extend 5'
beyond the curb lines of all streets, alleys and parking areas.
6. It is the responsibility of the contractor to comply with all State and Federal Regulations
regarding construction activities near energized overhead power lines. Additionally, the contractor
shall coordinate all proposed work and procedures with the City of C.S. Electrical Division.
7. All materials & labor not identified as a Separate Bid Item shall be considered subsidiary
to the item in which it is used. All materials and equipment shall be both furnished and
installed unless otherwise noted.
8. The Contractor must provide construction staking from the ;nformation provide on these
plans.
9. All soil exposed by construction shall receive cellulose fibermulch seeding.
10. Trenches may be left open overnight if properly barricaded.
11. Adjustment of Water Meters, Valves, Manholes, Irrigation Systems, and any other Public or
Private Utility, etc. are not separate pay items. The Price of the adjustment shall be
subsidiary to the construction of Sewer Line, Force Main, etc.
12. The contractor shall coordinate with Suddenlink Communications, Atmos Energy, and
Verizon to adjust the location of existing facilities.
13. The contractor is responsible for traffic control. This is not a separate pay item.
14. No spoil areas are available on this site.
15. All roof and ground -mounted mechanical equipment shall be screened from view or
isolated so as not to be visible from any public right-of-way or residential district within 150'
of the subject lot, measured from a point five feet above grade. Such screening shall be
coordinated with the building architecture, materials, colors, and scale to maintain a unified
appearance.
16. Certificate of Occupancies may be requested for each building separately. Building
numbers are shown hereon in circles within each building footprint.
17. Building permits will not be issued for Buildings 6 and 7 until the existing public utility
easement underlying these buildings is duly abandoned by City Council.
18. All lots shown hereon are considered one building plot in terms of NRA standards and
signage.
19 All variances from PDD Zoning:
*Parking Required-1 per bedroom -residential uses and 1 per 250 SF -nonresidential uses
*Interior Islands are not required in side or rear parking areas.
*No buffer required adjacent to existing single family
*No front setback
*15' rear setback
*No height restrictions or other neighborhood protection standards
20. Buildings to be all 3 story, 40'-0" to peak.
SITE PLAN NOTES:
1. Name of Project: Wolf Point Center
2. Legal Description: Pooh's Park, Block 2, Lot 2R
3. Owner: James P. Miles
2917 Camille Drive
College Station, Texas 77845
(979) 777-4675
4. Engineer: Mitchell & Morgan, L.L.P.
511 University Drive East, Suite 204
College Station, Texas 77840
(979) 260-6963
5. Zoning: PDD
6. Existing Use: Undeveloped -Vacant
Building
-
#1 = 4,000 SF Commercial and 8,000 SF Residential
7.
Proposed Use: Commercial & Multi Family
Setbacks: Per City of College Station Ordinances
6-2
Bedroom
Units
8.
Site Area: 1.317 acres/ Density =XX du/acre
2-1
Bedroom
Units
9.
Water Demands: Min.=XX gpm, Avg.=XX gpm, Peak=XX gpm
10.
Sanitary Demands: XXXX GPD
Building
#2 & 3
= 12,000 SF Residential (Each)
Lot
2R is outside the 100 years flood plain, as identified by the federal emergency
management
agency on community panel no. 48041CO144 C. Dated July 2, 1992.
10-2
Bedroom
Units
2-1
Bedroom
Units
MITCHELL
Ngs M
MORGAN
T.979.260.6963
F.979.260.3564
TX, FIRM # F-1443
511 UNIVERSITY DRIVE EAST
SUITE 204
COLLEGE STATION, TX 77840
PLAN & DESIGN SPECIALISTS IN
CIVIL ENGINEERING H`IDRAULICS
HYDROLOGY *UTILITIES STREETS
SITE PLANS *SUBDIVISIONS
www.mitchellandmor an.com
o�� w
oo
O a o
0 2
3 aTrn rn
i g -� oao
EEoacmn
U d C;Q
Z
� � 0 0_
C V
o
C N
Y
OM
M
o»--D
CV
m
(1) m
�C:
aU ,M C U
twooU
0
O
L
O
LL_
W
N
Q- ' U
Q O
U
O
0
N
N
C�\1
V
O
Q
Q, N
O Z
O
O