HomeMy WebLinkAboutStaff CommentsJennifer Reeves - Lincoln R etail. DOC Page 2 MEMORANDUM July 9, 2004 TO: Marco A. Lopez 4314 Apollo street Houston TX, 77018 (713) 691 - 3385"51 Via Fax FROM: Bridgette George, Assistant Development Manager SUBJECT: LINCOLN RETAIL CENTER (SP) - Site Plan Staff reviewed the above - mentioned site plan as requested. The following page is a list of staff review comments detailing items that need to be addressed. The next submittal will be the third and final review by staff for this round of reviews. If all items have not been addressed on the next submittal, another $200 processing fee will need to be submitted for the subsequent set of three (3) reviews. Please address the comments and submit the following information for further staff review: Six (6) complete sets of construction documents for the proposed development with the revised site and landscaping plans attached (please submit additional copies to be stamped for your records). If there are comments that you are not addressing with the revised site plan, please attach a letter explaining the details. If you have any questions or need additional information, please call me at 764 -3570. Attachments: Staff review comments cc: Ponderosa Development Company (James W.Chang) (713) 626 -3394 Via Fax Cliff Kroll, 5005 River way, Suite 250 Houston TX, 77056 (713) 626 -3394 Via Fax Case file #04- 00500145 NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. 2of3 Jennifer Reeves -Lincoln Retail. Page 3 STAFF REVIEW COMMENTS NO.2 Project: LINCOLN RETAIL CENTER (SP) - 04- 00500145 PLANNING 1. Per site plan review #1, comment #8 "Please be aware that the existing pylon sign is located in TxDOT ROW and is not permitted. This is considered an off premise sign. TxDOT does not allow signs in the ROW ". Please be aware that this sign will have to be removed prior to C.O. 2. Please provide a ramp on the north end of the sidewalk that runs along Texas Avenue. LANDSCAPE 3. Streetscape is required for both Texas Avenue and Lincoln Avenue. The measurement for Texas is being shown under Lincoln. Please adjust this in the legend as well as providing both Texas and Lincoln streetscape requirements. Show what is required for each as well as what has been provided. 4. Per site plan review #1, comment #16 "(FYI) The minimum number of points for any development is 800 (Section 7.5.C.1.b), even if the site area calculation comes out less ". Points required for project area = 800 + 602 +Additional streetscape points for Lincoln Avenue. Please adjust point requirement in the legend. Reviewed by: Jennifer Reeves Date: 06 -30 -04 ENGINEERING 1. Add a construction exit and inlet protection (there is a grated inlet in parking lot and an inlet in Texas Avenue) to the Erosion Control Plan. 2. The required sidewalk is 4 -foot wide, 4 feet from back of curb. We would however; like to upgrade the sidewalk to match the existing sidewalk along Texas Avenue. The City has funds to contribute, but we need a little time to work out how to make it happen. If you could hold off the sidewalk portion along Texas Avenue until we can work this it would be appreciated, otherwise the 4 -foot sidewalk is all that is required. 3. How do you plan on transitioning the curb and sidewalk to the adjacent property? NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. 3of3 Jennifer Reeves - Lincoln Retail.DOC Page 4 Review NOTE: Any c explai that h; Lam. M, � e\ I) -y -may P1Z:52- Lq - T t CITY OF COLLEGE STATION DEVELOPMENT SERVICES 1101 Texas Avenue South, PO Box 9960 College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 MEMORANDUM July 9, 2004 TO: Marco A. Lopez 4314 Apollo street Houston TX, 77018 (713) 691 - 3385 *51 Via Fax FROM: Bridgette George, Assistant Development Manager SUBJECT: LINCOLN RETAIL CENTER (SP) - Site Plan Staff reviewed the above - mentioned site plan as requested. The following page is a list of staff review comments detailing items that need to be addressed. The next submittal will be the third and final review by staff for this round of reviews. If all items have not been addressed on the next submittal, another $200 processing fee will need to be submitted for the subsequent set of three (3) reviews. Please address the comments and submit the following information for further staff review: Six (6) complete sets of construction documents for the proposed development with the revised site and landscaping plans attached (please submit additional copies to be stamped for your records). If there are comments that you are not addressing with the revised site plan, please attach a letter explaining the details. If you have any questions or need additional information, please call me at 764 -3570. Attachments: Staff review comments cc: Ponderosa Development Company (James W.Chang) (713) 626 -3394 Via Fax Cliff Kroll, 5005 River way, Suite 250 Houston TX, 77056 (713) 626 -3394 Via Fax Home of Texas A &M University Case file #04- 00500145 STAFF REVIEW COMMENTS NO. 2 Project: LINCOLN RETAIL CENTER (SP) - 04- 00500145 PLANNING 1. Per site plan review #1, comment #8 "Please be aware that the existing pylon sign is located in TxDOT ROW and is not permitted. This is considered an off premise sign. TxDOT does not allow signs in the ROW ". Please be aware that this sign will have to be removed prior to C.O. 2. Please provide a ramp on the north end of the sidewalk that runs along Texas Avenue. LANDSCAPE 3. Streetscape is required for both Texas Avenue and Lincoln Avenue. The measurement for Texas is being shown under Lincoln. Please adjust this in the legend as well as providing both Texas and Lincoln streetscape requirements. Show what is required for each as well as what has been provided. 4. Per site plan review #1, comment #16 "(FYI) The minimum number of points for any development is 800 (Section 7.5.C.1.b), even if the site area calculation comes out less ". Points required for project area = 800 + 602 +Additional streetscape points for Lincoln Avenue. Please adjust point requirement in the legend. Reviewed by: Jennifer Reeves Date: 06 -30 -04 ENGINEERING 1. Add a construction exit and inlet protection (there is a grated inlet in parking lot and an inlet in Texas Avenue) to the Erosion Control Plan. 2. The required sidewalk is 4 -foot wide, 4 feet from back of curb. We would however; like to upgrade the sidewalk to match the existing sidewalk along Texas Avenue. The City has funds to contribute, but we need a little time to work out how to make it happen. If you could hold off the sidewalk portion NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. 2of3 along Texas Avenue until we can work this it would be appreciated, otherwise the 4 -foot sidewalk is all that is required. 3. How do you plan on transitioning the curb and sidewalk to the adjacent property? Reviewed by: Carol Cotter Date: July 9, 2004 NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. 3of3 MEMORANDUM June 22, 2004 TO: Cliff Kroll, 5005 River way, Suite 250 Houston TX, 77056 (713) 626 -3394 FROM: Jennifer Reeves, Project Manager SUBJECT: LINCOLN RETAIL CENTER (SP) - Site Plan Staff reviewed the above - mentioned site plan as requested. The following page is a list of staff review comments detailing items that need to be addressed. Please address the comments and submit the following information for further staff review: Two (2) revised complete sets of construction documents for the proposed development with the revised site and landscaping plans attached (please submit additional copies to be stamped for your records). Easement Dedication Sheet and required documents. Please note that the Easement Dedication Sheet and the necessary documents are required prior to the issuance of a building permit. If there are comments that you are not addressing with the revised site plan, please attach a letter explaining the details. If you have any questions or need additional information, please call me at 979.764.3570. Attachments: Staff Review comments cc: Ponderosa Development Company (James W.Chang) (713) 626 -3394 Marco A. Lopez 4314 Apollo street Houston TX, 77018 (713) 686 -7797 Case file #04- 00500145 NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. Page 2 of 5 STAFF REVIEW COMMENTS NO. 1 Project: LINCOLN RETAIL CENTER (SP) — 04- 00500145 This is a Stop review: Items that need to be addressed may affect the layout of the site (Pending Variances). The following comments do not constitute a full site plan review. PLANNING 1. (FYI) To the Site Contractor: Please be aware that the proposed building is setting on top of the building line setbacks and there is no room for error. 2. Provide a general note that all roof and ground- mounted mechanical equipment shall be screened from view or isolated so as not to be visible from any public right - of -way or residential district within 150' of the subject lot, measured from a point five feet above grade. Such screening shall be coordinated with the building architecture and scale to maintain a unified appearance. 3. Please provide vicinity map (shown on the survey) on the site plan. a�4. Please note on the site plan the current zoning of the subject property as well as the abutting parcels. (Subject property is zoned C -1 general Commercial) 5. Per site plan check list and per Section 7.3 of the Unified Development Ordinance, please show opposite and adjacent driveways and separation distances. A. (FYI) Please be aware as discussed in the pre - application meeting on January 26, J 7 2004 that three or more retail /commercial uses is considered a shopping center and will require parking at 1/150. . The ordinance requires a 180 - square foot end island at the end of every parking row. However it appears that the parking space facing Lincoln Street and adjacent to Tract A (East Gate Square) is without an end island, so there is no where for the parked car to back out to. Staff is allowed to grant a variance as long as the variance is 10% or less. Granting a variance to the whole 180 - sqaure feet end- island is more than 10 %, however staff could grant a variance to one parking space and allow for 13 parking spaces instead of the 14 that are required. If the applicant wants to pursue a staff level variance for one parking space please fill out the appropriate application in Development Services or download one off our city web site (www.cstx.gov) and submit. Please be aware that plans cannot be stamped approved without this variance unless the site is designed to meet the ordinance. 8. Please be aware that the existing pylon sign is located in TxDOT ROW and is not permitted. This is considered an off premise sign. TxDOT does not allow signs in the ROW. 9. The proposed curb is not acceptable. The City of College Station requires a six -inch monolithic curb with #4 Bar. LAN DSCAPING /STREETSCAPING /BU FIFE /11. Provide a general note that 100% coverage of groundcover, decorative paving, decorative rock, or a perennial grass is required in parking lot islands, swales and NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. Page 3 of 5 drainage areas, the parking lot setback, rights -of -way, and adjacent property disturbed during construction. J12. Please be aware that dwarf specie parking 9 ecie shrubs are not allowed for arkin screening. All ' screening shrubs are required to be 3 -feet in height at planting stage. \J1 3. The parking space adjacent to the end island to the right as you pull into the site i from Lincoln will need screening shrubs (can be seen from the row). Q 4. (FYI) Please be aware that all mulched areas are required to stay maintained at all times. �15. Please include Lincoln Street in the streetscape calculation requirement. 16. (FYI) The minimum number of points for any development is 800 (Section 7.5.C.1.b), even if the site area calculation comes out less. �11 7. Please amend irrigation note on the landscape plan to say: An irrigation plan must be reviewed and approved prior to C.O. Reviewed by: Jennifer Reeves Date: 06 -22 -04 ENGINEERING Remove all existing encroachments in TxDOT ROW. The driveway off of Texas Avenue is required to be removed with associated concrete and parking in ROW. All disturbed areas must have established grass prior to C.O. 2. Provide Water Design Report. V Provide Erosion Control Plan. 4. Developer provides temporary blanket easement for construction purposes. (To release temporary blanket easement developer provides descriptive meets and bounds easements for all public infrastructure as installed.) 5 / Show all existing easements. Provide curb return radii on driveway. Show location of irrigation meter. Water and irrigation meters are required to be in a PUE. P/The water service as proposed is a public line until the meter. Please relocate meter to tap off main line or provide engineered construction documents for the � of the public portion of the proposed line. Provide water and sewer demands. 1 Continue sidewalk to tie in to location of existing sidewalk on Texas Avenue. Reviewed by: Carol Cotter Date: 06 -22 -04 NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. Page 4 of 5 ELECTRICAL 1. Developer installs conduit per city specs and design. 2. Developer pours transformer pad(s) per city specs and design. 3. We have been working with the construction contractor on the requirements for electric service: transformer location, conduit installation and routing. 4. Developer provides temporary blanket easement for construction purposes. (To release temporary blanket easement developer provides descriptive meets and bounds easements for electric infrastructure as installed.) Reviewed by: Tony Michalsky Date: 6 -22 -04 MISCELLANEOUS 1. Irrigation system must be protected by either a Pressure Vacuum Breaker, a Reduced Pressure Principle Back Flow Device, or a Double -Check Back Flow Device, and installed as per City Ordinance 2394. 2. All BackFlow devices must be installed and tested upon installation as per City Ordinance 2394. NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. Page 5 of 5 CITY OF COLLEGE STATION DEVELOPMENT SERVICES 1101 Texas Avenue South, PO Box 9960 College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 MEMORANDUM July 9, 2004 TO: Cliff Kroll, 5005 River way, Suite 250 Houston TX, 77056 (713) 626 -3394 Via Fax FROM: Bridgette George, Assistant Development Manager SUBJECT: LINCOLN RETAIL CENTER (SP) - Site Plan Staff reviewed the above - mentioned site plan as requested. The following page is a list of staff review comments detailing items that need to be addressed. The next submittal will be the third and final review by staff for this round of reviews. If all items have not been addressed on the next submittal, another $200 processing fee will need to be submitted for the subsequent set of three (3) reviews. Please address the comments and submit the following information for further staff review: Six (6) complete sets of construction documents for the proposed development with the revised site and landscaping plans attached (please submit additional copies to be stamped for your records). If there are comments that you are not addressing with the revised site plan, please attach a letter explaining the details. If you have any questions or need additional information, please call me at 764 -3570. Attachments: Staff review comments cc: Ponderosa Development Company (James W.Chang) (713) 626 -3394 Via Fax Marco A. Lopez 4314 Apollo street Houston TX, 77018 (713) 691 - 3385 *51 Via Fax Home of Texas A &M University Case file #04- 00500145 STAFF REVIEW COMMENTS NO.2 Project: LINCOLN RETAIL CENTER (SP) - 04- 00500145 PLANNING 1. Per site plan review #1, comment #8 "Please be aware that the existing pylon sign is located in TxDOT ROW and is not permitted. This is considered an off premise sign. TxDOT does not allow signs in the ROW ". Please be aware that this sign will have to be removed prior to C.O. 2. Please provide a ramp on the north end of the sidewalk that runs along Texas Avenue. LANDSCAPE 3. Streetscape is required for both Texas Avenue and Lincoln Avenue. The measurement for Texas is being shown under Lincoln. Please adjust this in the legend as well as providing both Texas and Lincoln streetscape requirements. Show what is required for each as well as what has been provided. 4. Per site plan review #1, comment #16 "(FYI) The minimum number of points for any development is 800 (Section 7.5.C.1.b), even if the site area calculation comes out less ". Points required for project area = 800 + 602 +Additional streetscape points for Lincoln Avenue. Please adjust point requirement in the legend. Reviewed by: Jennifer Reeves Date: 06 -30 -04 ENGINEERING 1. Add a construction exit and inlet protection (there is a grated inlet in parking lot and an inlet in Texas Avenue) to the Erosion Control Plan. 2. The required sidewalk is 4 -foot wide, 4 feet from back of curb. We would however; like to upgrade the sidewalk to match the existing sidewalk along Texas Avenue. The City has funds to contribute, but we need a little time to work out how to make it happen. If you could hold off the sidewalk portion along Texas Avenue until we can work this it would be appreciated, otherwise the 4 -foot sidewalk is all that is required. NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. 2 of 3 3. How do you plan on transitioning the curb and sidewalk to the adjacent property? Reviewed by: Carol Cotter Date: July 9, 2004 NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. 3of3 CITY OF COLLEGE STATION DEVELOPMENT SERVICES 1101 Texas Avenue South, PO Box 9960 College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 MEMORANDUM July 9, 2004 TO: Marco A. Lopez 4314 Apollo street Houston TX, 77018 (713) 691 - 3385 *51 Via Fax FROM: Bridgette George, Assistant Development Manager SUBJECT: LINCOLN RETAIL CENTER (SP) - Site Plan Staff reviewed the above - mentioned site plan as requested. The following page is a list of staff review comments detailing items that need to be addressed. The next submittal will be the third and final review by staff for this round of reviews. If all items have not been addressed on the next submittal, another $200 processing fee will need to be submitted for the subsequent set of three (3) reviews. Please address the comments and submit the following information for further staff review: Six (6) complete sets of construction documents for the proposed development with the revised site and landscaping plans attached (please submit additional copies to be stamped for your records). If there are comments that you are not addressing with the revised site plan, please attach a letter explaining the details. If you have any questions or need additional information, please call me at 764 -3570. Attachments: Staff review comments cc: Ponderosa Development Company (James W.Chang) (713) 626 -3394 Via Fax Cliff Kroll, 5005 River way, Suite 250 Houston TX, 77056 (713) 626 -3394 Via Fax Home of Texas A&M University Case file #04- 00500145 STAFF REVIEW COMMENTS NO.2 Project: LINCOLN RETAIL CENTER (SP) - 04- 00500145 PLANNING 1. Per site plan review #1, comment #8 "Please be aware that the existing pylon sign is located in TxDOT ROW and is not permitted. This is considered an off premise sign. TxDOT does not allow signs in the ROW ". Please be aware that this sign will have to be removed prior to C.O. 2. Please provide a ramp on the north end of the sidewalk that runs along Texas Avenue. LANDSCAPE 3. Streetscape is required for both Texas Avenue and Lincoln Avenue. The measurement for Texas is being shown under Lincoln. Please adjust this in the legend as well as providing both Texas and Lincoln streetscape requirements. Show what is required for each as well as what has been provided. 4. Per site plan review #1, comment #16 "(FYI) The minimum number of points for any development is 800 (Section 7.5.C.1.b), even if the site area calculation comes out less ". Points required for project area = 800 + 602 +Additional streetscape points for Lincoln Avenue. Please adjust point requirement in the legend. Reviewed by: Jennifer Reeves Date: 06 -30 -04 ENGINEERING 1. Add a construction exit and inlet protection (there is a grated inlet in parking lot and an inlet in Texas Avenue) to the Erosion Control Plan. 2. The required sidewalk is 4 -foot wide, 4 feet from back of curb. We would however; like to upgrade the sidewalk to match the existing sidewalk along Texas Avenue. The City has funds to contribute, but we need a little time to work out how to make it happen. If you could hold off the sidewalk portion NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. 2 of 3 along Texas Avenue until we can work this it would be appreciated, otherwise the 4 -foot sidewalk is all that is required. 3. How do you plan on transitioning the curb and sidewalk to the adjacent property? Reviewed by: Carol Cotter Date: July 9, 2004 NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. 3of3 MEMORANDUM June 22, 2004 TO: Marco A. Lopez 4314 Apollo street Houston TX, 77018 (713) 686 -7797 FROM: Jennifer Reeves, Project Manager SUBJECT: LINCOLN RETAIL CENTER (SP) - Site Plan Staff reviewed the above - mentioned site plan as requested. The following page is a list of staff review comments detailing items that need to be addressed. Please address the comments and submit the following information for further staff review: Two (2) revised complete sets of construction documents for the proposed development with the revised site and landscaping plans attached (please submit additional copies to be stamped for your records). Easement Dedication Sheet and required documents. Please note that the Easement Dedication Sheet and the necessary documents are required prior to the issuance of a building permit. If there are comments that you are not addressing with the revised site plan, please attach a letter explaining the details. If you have any questions or need additional information, please call me at 979.764.3570. Attachments: Staff Review comments cc: Cliff Kroll, 5005 River way, Suite 250 Houston TX, 77056 (713) 626 -3394 Ponderosa Development Company (James W.Chang) (713) 626 -3394 Case file #04- 00500145 NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. Page 2 of 5 STAFF REVIEW COMMENTS NO. 1 Project: LINCOLN RETAIL CENTER (SP) — 04- 00500145 This is a Stop review: Items that need to be addressed may affect the layout of the site (Pending Variances). The following comments do not constitute a full site plan review. PLANNING 1. (FYI) To the Site Contractor: Please be aware that the proposed building is setting on top of the building line setbacks and there is no room for error. 2. Provide a general note that all roof and ground- mounted mechanical equipment shall be screened from view or isolated so as not to be visible from any public right - of -way or residential district within 150' of the subject lot, measured from a point five feet above grade. Such screening shall be coordinated with the building architecture and scale to maintain a unified appearance. 3. Please provide vicinity map (shown on the survey) on the site plan. 4. Please note on the site plan the current zoning of the subject property as well as the abutting parcels. (Subject property is zoned C -1 general Commercial) 5. Per site plan check list and per Section 7.3 of the Unified Development Ordinance, please show opposite and adjacent driveways and separation distances. 6. (FYI) Please be aware as discussed in the pre - application meeting on January 26, 2004 that three or more retail /commercial uses is considered a shopping center and will require parking at 1/150. 7. The ordinance requires a 180 - square foot end island at the end of every parking row. However it appears that the parking space facing Lincoln Street and adjacent to Tract A (East Gate Square) is without an end island, so there is no where for the parked car to back out to. Staff is allowed to grant a variance as long as the variance is 10% or less. Granting a variance to the whole 180 - sqaure feet end - island is more than 10 %, however staff could grant a variance to one parking space and allow for 13 parking spaces instead of the 14 that are required. If the applicant wants to pursue a staff level variance for one parking space please fill out the appropriate application in Development Services or download one off our city web site (www.cstx.gov) and submit. Please be aware that plans cannot be stamped approved without this variance unless the site is designed to meet the ordinance. 8. Please be aware that the existing pylon sign is located in TxDOT ROW and is not permitted. This is considered an off premise sign. TxDOT does not allow signs in the ROW. 9. The proposed curb is not acceptable. The City of College Station requires a six -inch monolithic curb with #4 Bar. NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. Page 3 of 5 LANDSCAPING /STREETSCAPING /BUFFER 11. Provide a general note that 100% coverage of groundcover, decorative paving, decorative rock, or a perennial grass is required in parking lot islands, swales and drainage areas, the parking lot setback, rights -of -way, and adjacent property disturbed during construction. 12. Please be aware that dwarf specie shrubs are not allowed for parking screening. All screening shrubs are required to be 3 -feet in height at planting stage. 13. The parking space adjacent to the end island to the right as you pull into the site from Lincoln will need screening shrubs (can be seen from the row). 14. (FYI) Please be aware that all mulched areas are required to stay maintained at all times. 15. Please include Lincoln Street in the streetscape calculation requirement. 16. (FYI) The minimum number of points for any development is 800 (Section 7.5.C.1.b), even if the site area calculation comes out less. 17. Please amend irrigation note on the landscape plan to say: An irrigation plan must be reviewed and approved prior to C.O. Reviewed by: Jennifer Reeves Date: 06 -22 -04 ENGINEERING 1. Remove all existing encroachments in TxDOT ROW. The driveway off of Texas Avenue is required to be removed with associated concrete and parking in ROW. All disturbed areas must have established grass prior to C.O. 2. Provide Water Design Report. 3. Provide Erosion Control Plan. 4. Developer provides temporary blanket easement for construction purposes. (To release temporary blanket easement developer provides descriptive meets and bounds easements for all public infrastructure as installed.) 5. Show all existing easements. 6. Provide curb return radii on driveway. 7. Show location of irrigation meter. Water and irrigation meters are required to be in a PUE. 8. The water service as proposed is a public line until the meter. Please relocate meter to tap off main line or provide engineered construction documents for the extension of the public portion of the proposed line. 9. Provide water and sewer demands. 10. Continue sidewalk to tie in to location of existing sidewalk on Texas Avenue. Reviewed by: Carol Cotter Date: 06 -22 -04 NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and 'bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. Page 4 of 5 ELECTRICAL 1. Developer installs conduit per city specs and design. 2. Developer pours transformer pad(s) per city specs and design. 3. We have been working with the construction contractor on the requirements for electric service: transformer location, conduit installation and routing. 4. Developer provides temporary blanket easement for construction purposes. (To release temporary blanket easement developer provides descriptive meets and bounds easements for electric infrastructure as installed.) Reviewed by: Tony Michalsky Date: 6 -22 -04 MISCELLANEOUS 1. Irrigation system must be protected by either a Pressure Vacuum Breaker, a Reduced Pressure Principle Back Flow Device, or a Double -Check Back Flow Device, and installed as per City Ordinance 2394. 2. All BackFlow devices must be installed and tested upon installation as per City Ordinance 2394. NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. Page 5 of 5 MEMORANDUM June 22, 2004 TO: Ponderosa Development Company (James W.Chang) (713) 626 -3394 FROM: Jennifer Reeves, Project Manager SUBJECT: LINCOLN RETAIL CENTER (SP) - Site Plan Staff reviewed the above - mentioned site plan as requested. The following page is a list of staff review comments detailing items that need to be addressed. Please address the comments and submit the following information for further staff review: Two (2) revised complete sets of construction documents for the proposed development with the revised site and landscaping plans attached (please submit additional copies to be stamped for your records). Easement Dedication Sheet and required documents. Please note that the Easement Dedication Sheet and the necessary documents are required prior to the issuance of a building permit. If there are comments that you are not addressing with the revised site plan, please attach a letter explaining the details. If you have any questions or need additional information, please call me at 979.764.3570. Attachments: Staff Review comments cc: Cliff Kroll, 5005 River way, Suite 250 Houston TX, 77056 (713) 626 -3394 Marco A. Lopez 4314 Apollo street Houston TX, 77018 (713) 686 -7797 Case file #04- 00500145 NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. Page 2 of 5 STAFF REVIEW COMMENTS NO. 1 Project: LINCOLN RETAIL CENTER (SP) — 04- 00500145 This is a Stop review: Items that need to be addressed may affect the layout of the site (Pending Variances). The following comments do not constitute a full site plan review. PLANNING 1. (FYI) To the Site Contractor: Please be aware that the proposed building is setting on top of the building line setbacks and there is no room for error. 2. Provide a general note that all roof and ground- mounted mechanical equipment shall be screened from view or isolated so as not to be visible from any public right - of -way or residential district within 150' of the subject lot, measured from a point five feet above grade. Such screening shall be coordinated with the building architecture and scale to maintain a unified appearance. 3. Please provide vicinity map (shown on the survey) on the site plan. 4. Please note on the site plan the current zoning of the subject property as well as the abutting parcels. (Subject property is zoned C -1 general Commercial) 5. Per site plan check list and per Section 7.3 of the Unified Development Ordinance, please show opposite and adjacent driveways and separation distances. 6. (FYI) Please be aware as discussed in the pre - application meeting on January 26, 2004 that three or more retail /commercial uses is considered a shopping center and will require parking at 1/150. 7. The ordinance requires a 180 - square foot end island at the end of every parking row. However it appears that the parking space facing Lincoln Street and adjacent to Tract A (East Gate Square) is without an end island, so there is no where for the parked car to back out to. Staff is allowed to grant a variance as long as the variance is 10% or less. Granting a variance to the whole 180 - sqaure feet end - island is more than 10 %, however staff could grant a variance to one parking space and allow for 13 parking spaces instead of the 14 that are required. If the applicant wants to pursue a staff level variance for one parking space please fill out the appropriate application in Development Services or download one off our city web site (www.cstx.gov) and submit. Please be aware that plans cannot be stamped approved without this variance unless the site is designed to meet the ordinance. 8. Please be aware that the existing pylon sign is located in TxDOT ROW and is not permitted. This is considered an off premise sign. TxDOT does not allow signs in the ROW. 9. The proposed curb is not acceptable. The City of College Station requires a six -inch monolithic curb with #4 Bar. LANDSCAPING /STREETSCAPING /BUFFER 11. Provide a general note that 100% coverage of groundcover, decorative paving, decorative rock, or a perennial grass is required in parking lot islands, swales and NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. Page 3 of 5 drainage areas, the parking lot setback, rights -of -way, and adjacent property disturbed during construction. 12. Please be aware that dwarf specie shrubs are not allowed for parking screening. All screening shrubs are required to be 3 -feet in height at planting stage. 13. The parking space adjacent to the end island to the right as you pull into the site from Lincoln will need screening shrubs (can be seen from the row). 14. (FYI) Please be aware that all mulched areas are required to stay maintained at all times. 15. Please include Lincoln Street in the streetscape calculation requirement. 16. (FYI) The minimum number of points for any development is 800 (Section 7.5.C.1.b), even if the site area calculation comes out less. 17. Please amend irrigation note on the landscape plan to say: An irrigation plan must be reviewed and approved prior to C.O. Reviewed by: Jennifer Reeves Date: 06 -22 -04 ENGINEERING 1. Remove all existing encroachments in TxDOT ROW. The driveway off of Texas Avenue is required to be removed with associated concrete and parking in ROW. All disturbed areas must have established grass prior to C.O. 2. Provide Water Design Report. 3. Provide Erosion Control Plan. 4. Developer provides temporary blanket easement for construction purposes. (To release temporary blanket easement developer provides descriptive meets and bounds easements for all public infrastructure as installed.) 5. Show all existing easements. 6. Provide curb return radii on driveway. 7. Show location of irrigation meter. Water and irrigation meters are required to be in a PUE. 8. The water service as proposed is a public line until the meter. Please relocate meter to tap off main line or provide engineered construction documents for the extension of the public portion of the proposed line. 9. Provide water and sewer demands. 10. Continue sidewalk to tie in to location of existing sidewalk on Texas Avenue. Reviewed by: Carol Cotter Date: 06 -22 -04 NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. Page 4 of 5 . . 1 . ELECTRICAL 1. Developer installs conduit per city specs and design. 2. Developer pours transformer pad(s) per city specs and design. 3. We have been working with the construction contractor on the requirements for electric service: transformer location, conduit installation and routing. 4. Developer provides temporary blanket easement for construction purposes. (To release temporary blanket easement developer provides descriptive meets and bounds easements for electric infrastructure as installed.) Reviewed by: Tony Michalsky Date: 6 -22 -04 MISCELLANEOUS 1. Irrigation system must be protected by either a Pressure Vacuum Breaker, a Reduced Pressure Principle Back Flow Device, or a Double -Check Back Flow Device, and installed as per City Ordinance 2394. 2. All BackFlow devices must be installed and tested upon installation as per City Ordinance 2394. NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled' on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. Page 5 of 5 07/:9/2004 14:10 9797643496 COCS DEVELUFMENI 5tK . �� en �► ono �cr }� or8OR rHQr- utI uo 1� _1 CITY OF COLLEGE STATION DEVELOPMENT SERVICES 1101 Texas Avenue South, PO Box 9960 College Station, Texas 77842 Phone 979.764.3570 / Fax 979 .764.3496 MEMORANDUM July 9, 2004 TO: Marco A. Lopez 4314 Apollo street Houston TX, 77018 (713) 69 3385`51 Via Fax FROM: Bridgettc George, Assistant Development Manager SUBJECT: LINCOLN RETAIL CENTER (SP) - Site Plan Staff reviewed the above- mentioned site plan as requested. The following page is a list of staff review comments detailing items that need to be Addressed. The next submittal will be the third and final review by staff for this round of reviews. If all items have not been addressed on the next submittal, another $200 processing fee will need to be submitted for the subsequent set of three (3) reviews. Please address the comments and submit the following information for further staff review: Six (6) complete sets of construction documents for tho proposed development with the revised site and landscaping plans attached (please submit additional copies to be stamped for your records). If there are comments that you are not addressing with the revised site plan, please attach a letter explaining the details. if you have any questions or need additional information, please call me at 764 -3570. Attachments: Staff review comments cc: Ponderosa Development Company (James W.Chang) (713) 626 -3394 Via Fax Cliff Kroll, 5005 River way, Suite 250 Houston TX, 77056 (713) 626 -3394 Via Fax Home of Texas A&M University 07/09/2004 14:10 9797643496 COCS DEVELOPMENI SEN Case file 004- 00500145 STAFF REVIEW COMMENTS NO.2 Project: LINCOLN RETAIL CENTER (SP) - 04- 00500145 PLANNING r'HUG UL/ Ula 1. Per site plan review #1, comment #8 "Please be aware that the existing pylon sign is located in TxDOT ROW and is riot permitted. This is considered an off premise sign, TxDOT doss not allow signs in the ROW. Please be aware that this sign will have to be removed prior to C.O. 2. Please provide a ramp on the north end of the sidewalk that runs along Texas Avenue. LANDSCAPE 3. Streetscape is required for both Texas Avenue and Lincoln Avenue. The moesurement for Texas is being shown under Lincoln. Please adjust this in the legend as well as providing both Texas and Lincoln streetscape requirements. Show what is roquired for each as well as what has been provided. 4. Per site plan review #1, comment #16 "(FYI) The minimum number of points for any development is 800 (Section 7.5.C.1.b), even if the site area calculation comes out less ". Points requirod for project area = 900 + 602 +Additional streetscape points for Lincoln Avenue. Please adjust point requirement in the legend. Reviewed by: ENGINEERING Jennifer Reeves Date: 06 -30 -04 1. Add a construction exit and inlet protection (there is a grated Inlet In parking lot and an inlet in Texas Avenue) to the Erosion Control Plan. 2. The regt_Iired sidewalk is 4-foot wide, 4 feet from back of curb. We would however; like to upgrade the sidewalk to match the existing sidewalk along Texas Avenue. The City has funds to contribute, but we need a little time to work out how to make it happen. If you could hold off the sidewalk portion NOTE: Any changes made to the plans, that have not been requested by the City of college Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additlonal changes on these plane that have not been pointed out to the City, YAI constitute a completely new review. 2of3 07/09/2004 14:10 9797643496 COCS DEVELOPMENT SER FAUL e.J/nd along Texas Avenue until we can work thls it would be appreciated, othermse the 4 -foot sidewalk is all that is required. 3. How do you plan on transitloning the curb and sidewalk to the adjacent property? Reviewed by: Caml Cotter Date. July 9, 2004 NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained In your ne)d transmlttai letter and 'bubbled' on your plans. Any addldonal changes on these plans thel have not been pointed out to the City, will constitute a completely new review. 3of3 CITY OF COLLEGE STATION DEVELOPMENT SERVICES 1101 Texas Avenue South, PO Box 9960 College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 MEMORANDUM July 9, 2004 TO: Ponderosa Development Company (James W.Chang) (713) 626 -3394 Via Fax FROM: Bridgette George, Assistant Development Manager SUBJECT: LINCOLN RETAIL CENTER (SP) - Site Plan Staff reviewed the above - mentioned site plan as requested. The following page is a list of staff review comments detailing items that need to be addressed. The next submittal will be the third and final review by staff for this round of reviews. If all items have not been addressed on the next submittal, another $200 processing fee will need to be submitted for the subsequent set of three (3) reviews. Please address the comments and submit the following information for further staff review: Six (6) complete sets of construction documents for the proposed development with the revised site and landscaping plans attached (please submit additional copies to be stamped for your records). If there are comments that you are not addressing with the revised site plan, please attach a letter explaining the details. If you have any questions or need additional information, please call me at 764 -3570. Attachments: Staff review comments cc: Cliff Kroll, 5005 River way, Suite 250 Houston TX, 77056 (713) 626 -3394 Via Fax Marco A. Lopez 4314 Apollo street Houston TX, 77018 (713) 691 - 3385 *51 Via Fax Home of Texas A &M University Case file #04- 00500145 STAFF REVIEW COMMENTS NO.2 Project: LINCOLN RETAIL CENTER (SP) - 04- 00500145 PLANNING /1. Per site plan review #1, comment #8 "Please be aware that the existing pylon sign is located in TxDOT ROW and is not permitted. This is considered an off premise sign. TxDOT does not allow signs in the ROW ". Please be aware that this sign will have to be removed prior to C.O. .h. Please provide a ramp on the north end of the sidewalk that runs along Texas Avenue. LANDSCAPE ✓ 3. Streetscape is required for both Texas Avenue and Lincoln Avenue. The measurement for Texas is being shown under Lincoln. Please adjust this in the legend as well as providing both Texas and Lincoln streetscape requirements. Show what is required for each as well as what has been provided. J4. Per site plan review #1, comment #16 "(FYI) The minimum number of points for any development is 800 (Section 7.5.C.1.b), even if the site area calculation comes out less ". Points required for project area = 800 + 602 +Additional streetscape points for Lincoln Avenue. Please adjust point requirement in the legend. Reviewed by: Jennifer Reeves Date: 06 -30 -04 ENGINEERING 1. Add a construction exit and inlet protection (there is a grated inlet in parking lot and an inlet in Texas Avenue) to the Erosion Control Plan. 2. The required sidewalk is 4 -foot wide, 4 feet from back of curb. We would however; like to upgrade the sidewalk to match the existing sidewalk along Texas Avenue. The City has funds to contribute, but we need a little time to work out how to make it happen. If you could hold off the sidewalk portion along Texas Avenue until we can work this it would be appreciated, otherwise the 4 -foot sidewalk is all that is required. NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. 2 of 3 3. How do you plan on transitioning the curb and sidewalk to the adjacent property? Reviewed by: Carol Cotter Date: July 9, 2004 NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. 3of3 TRANSMISSION VERIFICATION REPORT TIME 07109/2004 14:07 NAME COOS DEVELOPMENT SER FAX 9797643496 TEL 9797643570 SER.# BROE2J341073 DATE,TIME FAX NO. /NAME DURATION PAGE(S) RESULT MODE 07109 14:06 917136263394- -170 00:00:47 03 OK STANDARD ECM CITY OF COLLEGE STATION DEVELOPMENT SERVICES 1101 Texas Avenue South, P4 Box 9960 College Station, Texas 77842 Phone 979.764.35701 Fax 979.764.3496 MEMORANDUM July 9, 2004 TO: Ponderosa Development Company (James W.Chang) (713) 626 -3394 Via Fax FROM: Bridgette George, Assistant Development Monagcr SUBJECT: LINCOLN RETAIL CENTER (SP) - Site Plan Staff reviewed the above - mentioned site plan as requested. The following page is a list of staff review comments detailing items that need to be addressed. The next submittal will be the third and final review by staff for this round of reviews. If all items have not been addressed on the next submittal, another $200 processing fee will need to be submitted for the subsequent set of three (3) reviews. Please address the comments and submit the following information for further starr review: Six (6) comolete sets of construction dor:uments for the proposed 4 J CITY OF COLLEGE STATION DEVELOPMENT SERVICES 1101 Texas Avenue South, PO Box 9960 College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 MEMORANDUM July 16, 2004 TO: Marco A. Lopez, via fax 713.691.3385 *51L / FROM: Bridgette George, Assistant Development Manager SUBJECT: LINCOLN RETAIL CENTER (SP) - Site Plan Staff reviewed the above - mentioned site plan as requested. The following page is a list of staff review comments detailing items that need to be addressed. Please address the comments and submit the following information for stamping: Six (6) complete sets of construction documents for the proposed development with the revised site and landscaping plans attached; Two (2) revised site; and One (1) landscaping plan. If there are comments that you are not addressing with the revised site plan, please attach a letter explaining the details. If you have any questions or need additional information, please call me at 764 -3570. Attachments: Staff review comments cc: James W.Chang, Ponderosa Development Company, via Fax 713.626.3394 ✓ Cliff Kroll, via fax 713.626.3394 Case file #04- 00500145 Home of Texas A &M University STAFF REVIEW COMMENTS NO. 3 Project: LINCOLN RETAIL CENTER (SP) - 04- 00500145 PLANNING 1. Sheets L1.0 & AS are still reflecting 14 parking spaces. Sheet AS still has the parking requirement as 13.7 parking spaces required and 14 provided. All sheets need to reflect the correct site layout. Please make these adjustments. 2. The curbing along Texas Avenue is required with a 4 -foot sidewalk, 4 feet back of curb. Between the curb and the 4 -foot sidewalk sod (established grass) will be required. Between the side walk and the property line the pavement may not be removed (per the phone conversation between Carol Cotter and Marco Lopez). If the pavement between the sidewalk and the property line is removed, this will require TxDOT permits. 3. The sidewalk along Lincoln Avenue that is in the TxDOT ROW will require sod between the sidewalk and curb. Reviewed by: Jennifer Reeves Date: 07 -15 -04 ENGINEERING 1. Delete curbing shown in TxDOT ROW along northwest adjacent property line. The curbing should stop at the sidewalk. 2. Make sure the sidewalk is 4 feet from back of curb along Lincoln Avenue, accept where there is an unavoidable conflict. 3. You will need to add curbing along your property line with TxDOT ROW, since the existing pavement will remain. 4. Hold off on all sidewalk in the TxDOT ROW until we can work out the details for the upgraded sidewalk along Texas Ave. The tie -in of the Lincoln Ave sidewalk could be effected by the sidewalk that will be constructed along Texas Ave. Reviewed by: Carol Cotter Date: July 16, 2004 NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. 2 of 2 TO: Marco A. Lopez, via fax 713.691.3385`51 FROM: Bridgette George, Assistant Development Manager SUBJECT: LINCOLN RETAIL CENTER (SP) - Site Plan Staff reviewed the above - mentioned site plan as requested. The following page is a list of staff review comments detailing items that need to be addressed. Please address the comments and submit the following information for stamping: Six (6) complete sets of construction documents for the proposed development with the revised site and landscaping plans attached; Two (2) revised site; and One (1) landscaping plan. If there are comments that you are not addressing with the revised site plan, please attach a letter explaining the details. If you have any questions or need additional information, please call me at 764 -3570. Attachments: Staff review comments cc: James W.Chang, Ponderosa Development Company, via Fax 713.626.3394 ✓ Cliff Kroll, via fax 713.626.3394 ✓ Case file #04- 00500145 Home of Texas A&M UnAwrsityr W03 GdVa a1S NO Z0 tib : 00 : 00 OLT-- TSx98EET69ETLT6 EE :ST 6T /LO 3QOW l (S)30bd NOI ivdnQ 3WVN /'ON Xd3 3WI1`31dQ ELOTV Z30d8 OLSEb9L6L6 96V6V9L6L6 a3S 1N3Wd003A3Q S000 tiE :ST b00Z /6T /LO # ' N3S X31 Xt 3 3HVN 3WI1 iNOd3d NOIiVOL IN3A NOISSIWSNVNi